Sato E, Tanaka E, Mori H, Kawai T, Ichimaru T, Sato S, Takayama K, Ido H. Demonstration of enhanced K-edge angiography using a cerium target x-ray generator.
Med Phys 2004;
31:3017-21. [PMID:
15587654 DOI:
10.1118/1.1803433]
[Citation(s) in RCA: 37] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
The cerium target x-ray generator is useful in order to perform enhanced K-edge angiography using a cone beam because K-series characteristic x rays from the cerium target are absorbed effectively by iodine-based contrast mediums. The x-ray generator consists of a main controller, a unit with a Cockcroft-Walton circuit and a fixed anode x-ray tube, and a personal computer. The tube is a glass-enclosed diode with a cerium target and a 0.5-mm-thick beryllium window. The maximum tube voltage and current were 65 kV and 0.4 mA, respectively, and the focal-spot sizes were 1.0 x 1.3 mm. Cerium Kalpha lines were left using a barium sulfate filter, and the x-ray intensity was 0.48 microC/kg at 1.0 m from the source with a tube voltage of 60 kV, a current of 0.40 mA, and an exposure time of 1.0 s. Angiography was performed with a computed radiography system using iodine-based microspheres. In coronary angiography of nonliving animals, we observed fine blood vessels of approximately 100 microm with high contrasts.
Collapse