• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4624939)   Today's Articles (5651)   Subscriber (49431)
For: Sato E, Sagae M, Takahashi K, Shikoda A, Oizumi T, Hayasi Y, Tamakawa Y, Yanagisawa T. 10 kHz microsecond pulsed X-ray generator utilising a hot-cathode triode with variable durations for biomedical radiography. Med Biol Eng Comput 1994;32:295-301. [PMID: 7934253 DOI: 10.1007/bf02512525] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Number Cited by Other Article(s)
1
Sato E, Hayasi Y, Tanaka E, Mori H, Kawai T, Inoue T, Ogawa A, Sato S, Takayama K, Onagawa J, Ido H. Preliminary study for producing higher harmonic hard X-rays from weakly ionized nickel plasma. Radiat Phys Chem Oxf Engl 1993 2006. [DOI: 10.1016/j.radphyschem.2005.11.012] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
2
Sato E, Hayasi Y, Tanaka E, Mori H, Kawai T, Inoue T, Ogawa A, Sato S, Takayama K, Onagawa J, Ido H. K-edge angiography utilizing a tungsten plasma X-ray generator in conjunction with gadolinium-based contrast media. Radiat Phys Chem Oxf Engl 1993 2006. [DOI: 10.1016/j.radphyschem.2005.11.015] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
3
Tunable narrow-photon-energy X-ray generator utilizing a tungsten-target tube. Radiat Phys Chem Oxf Engl 1993 2006. [DOI: 10.1016/j.radphyschem.2005.11.019] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
4
Sato E, Tanaka E, Mori H, Kawai T, Ichimaru T, Sato S, Takayama K, Ido H. Demonstration of enhanced K-edge angiography using a cerium target x-ray generator. Med Phys 2004;31:3017-21. [PMID: 15587654 DOI: 10.1118/1.1803433] [Citation(s) in RCA: 37] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]  Open
PrevPage 1 of 1 1Next