• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4615184)   Today's Articles (5734)   Subscriber (49392)
For: Nevill AJ, Pepper MG, Whiting M. In-shoe foot pressure measurement system utilising piezoelectric film transducers. Med Biol Eng Comput 1995;33:76-81. [PMID: 7616786 DOI: 10.1007/bf02522950] [Citation(s) in RCA: 23] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Number Cited by Other Article(s)
1
Rajala S, Lekkala J. Plantar shear stress measurements - A review. Clin Biomech (Bristol, Avon) 2014;29:475-83. [PMID: 24820135 DOI: 10.1016/j.clinbiomech.2014.04.009] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/03/2014] [Revised: 04/15/2014] [Accepted: 04/17/2014] [Indexed: 02/07/2023]
2
Design and test of a soft plantar force measurement system for gait detection. SENSORS 2012. [PMID: 23208558 PMCID: PMC3571801 DOI: 10.3390/s121216628] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
3
Zijlstra W, Hof AL. Assessment of spatio-temporal gait parameters from trunk accelerations during human walking. Gait Posture 2003;18:1-10. [PMID: 14654202 DOI: 10.1016/s0966-6362(02)00190-x] [Citation(s) in RCA: 482] [Impact Index Per Article: 23.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
4
Kyriazis V, Rigas C. Temporal gait analysis of hip osteoarthritic patients operated with cementless hip replacement. Clin Biomech (Bristol, Avon) 2002;17:318-21. [PMID: 12034128 DOI: 10.1016/s0268-0033(02)00024-4] [Citation(s) in RCA: 45] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
5
Kyriazis V, Rigas C. Software for temporal gait data analysis. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2002;67:225-229. [PMID: 11853949 DOI: 10.1016/s0169-2607(01)00152-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
6
Kyriazis V, Rigas C. A cheap telemetric system for analyzing gait. Hum Mov Sci 2001;20:867-74. [PMID: 11792444 DOI: 10.1016/s0167-9457(01)00053-7] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
7
Kyriazis V, Rigas C, Xenakis T. A portable system for the measurement of the temporal parameters of gait. Prosthet Orthot Int 2001;25:96-101. [PMID: 11573887 DOI: 10.1080/03093640108726581] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
8
Randolph AL, Nelson M, Akkapeddi S, Levin A, Alexandrescu R. Reliability of measurements of pressures applied on the foot during walking by a computerized insole sensor system. Arch Phys Med Rehabil 2000;81:573-8. [PMID: 10807094 DOI: 10.1016/s0003-9993(00)90037-6] [Citation(s) in RCA: 58] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
9
Abboud RJ, Rowley DI, Newton RW. Lower limb muscle dysfunction may contribute to foot ulceration in diabetic patients. Clin Biomech (Bristol, Avon) 2000;15:37-45. [PMID: 10590343 DOI: 10.1016/s0268-0033(99)00038-8] [Citation(s) in RCA: 66] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
10
Eckhouse RH, Maulucci RA. A multimedia system for augmented sensory assessment and treatment of motor disabilities. TELEMATICS AND INFORMATICS 1997. [DOI: 10.1016/s0736-5853(96)00019-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
11
Akhlaghi F, Pepper MG. In-shoe biaxial shear force measurement: the Kent shear system. Med Biol Eng Comput 1996;34:315-7. [PMID: 8935501 DOI: 10.1007/bf02511246] [Citation(s) in RCA: 24] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
12
Cobb J, Claremont DJ. Transducers for foot pressure measurement: survey of recent developments. Med Biol Eng Comput 1995;33:525-32. [PMID: 7475382 DOI: 10.1007/bf02522509] [Citation(s) in RCA: 42] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA