1
|
Does Provisional Minifragment Fixation Prevent Compression With Dynamic Compression Plating? A Biomechanical Analysis. J Orthop Trauma 2021; 35:550-554. [PMID: 33935195 DOI: 10.1097/bot.0000000000002059] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 01/07/2021] [Indexed: 02/02/2023]
Abstract
OBJECTIVES To compare the compressive force generated by a 3.5-mm compression plate with and without provisional fixation using a 2.0-mm minifragment plate. METHODS Fourth generation composite large humeral sawbones underwent transection and were divided into 2 groups. The first group underwent fixation with a 3.5-mm compression plate; the second group underwent provisional fixation with a 2.0-mm plate followed by definitive fixation using a 3.5-mm plate. Using a load cell, the compressive force generated was measured after insertion of each of 2 eccentrical placed screws and the total compression recorded. RESULTS There was no difference in the force generated after each successive compression screw (P = 0.59 and 0.58, respectively). Likewise, there was no significant difference in the total compression generated when the preload was accounted for (P = 0.93). CONCLUSION Provisional minifragment fixation does not have any adverse effect on the forces generated during compression plating. These findings suggest that provisional minifragment plates do not need to be removed before definitive fixation.
Collapse
|
2
|
Quadlbauer S, Pezzei C, Jurkowitsch J, Rosenauer R, Pichler A, Schättin S, Hausner T, Leixnering M. Functional and radiological outcome of distal radius fractures stabilized by volar-locking plate with a minimum follow-up of 1 year. Arch Orthop Trauma Surg 2020; 140:843-852. [PMID: 32221705 DOI: 10.1007/s00402-020-03411-9] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/26/2019] [Indexed: 12/22/2022]
Abstract
INTRODUCTION Distal radius fractures (DRF) are the most common fractures of the upper extremities and incidence is expected to continue rising as life expectancy increases. Palmar locking plate stabilizing has since become the standard treatment for dorsally displaced DRF. Main aim of this study was to investigate correlation between radiological and clinical outcome in patients stabilized by palmar locking plate with a minimum follow-up of one year. METHODS A total of 524 patients with DRF, stabilized using palmar angular stable locking plate fixation were included in the study. Of these, 117 patients had to be excluded and another 177 were not accessible. The study group thus compromised 230 patients who returned for the follow-up investigation and were followed-up clinically and radiologically with a mean follow-up interval of 20 months. Outcome was evaluated using pain, range of motion (ROM) and grip strength parameters. In addition, self-assessment by patients was registered on the QuickDASH, PRWE and Mayo Score. The immediate postoperative and final checkup radiographs were scrutinized for alignment and intra-articular step-off. RESULTS Bivariant correlation analysis showed a significant correlation between ulnar variance and QuickDASH (r = 0.18, p = 0.01), grip strength (r = - 0.18, p = 0.04) and Mayo Score (r = - 0.23, p = 0.001). No significant differences could be found between an unacceptable (> 2 mm) and acceptable (< 2 mm) ulnar variance in respect of pain, ROM, grip strength and patient-reported outcome measurements. Age, gender, additional fracture to the ulnar styloid, or type of postoperative immobilization showed no significant or clinical important impact on the final patient-reported outcome. No significant differences in incidence of complications, ROM or loss of reduction could be found in any patients over or under 65 years of age. CONCLUSIONS Stabilization of DRF by palmar angular stable locking plate is a safe form of treatment and results in a good clinical and radiological outcome with low complication rate. Ulnar variance showed a significant correlation to grip strength, QuickDASH and Mayo Score, but an unacceptable ulnar variance (> 2 mm) was not associated with a worse clinical important outcome. Age (< 65/> 65 years), gender and type of immobilization had no impact on the complication rate or in the final functional or radiological outcome.
Collapse
Affiliation(s)
- Stefan Quadlbauer
- AUVA Trauma Hospital Lorenz Böhler, European Hand Trauma Center, Donaueschingenstrasse 13, 1200, Vienna, Austria. .,Ludwig Boltzmann Institute for Experimental Und Clinical Traumatology, AUVA Research Center, 1200, Vienna, Austria. .,Austrian Cluster for Tissue Regeneration, Vienna, Austria.
| | - Ch Pezzei
- AUVA Trauma Hospital Lorenz Böhler, European Hand Trauma Center, Donaueschingenstrasse 13, 1200, Vienna, Austria
| | - J Jurkowitsch
- AUVA Trauma Hospital Lorenz Böhler, European Hand Trauma Center, Donaueschingenstrasse 13, 1200, Vienna, Austria
| | - R Rosenauer
- AUVA Trauma Hospital Lorenz Böhler, European Hand Trauma Center, Donaueschingenstrasse 13, 1200, Vienna, Austria.,Ludwig Boltzmann Institute for Experimental Und Clinical Traumatology, AUVA Research Center, 1200, Vienna, Austria.,Austrian Cluster for Tissue Regeneration, Vienna, Austria
| | - A Pichler
- AUVA Trauma Hospital Lorenz Böhler, European Hand Trauma Center, Donaueschingenstrasse 13, 1200, Vienna, Austria
| | - S Schättin
- AUVA Trauma Hospital Lorenz Böhler, European Hand Trauma Center, Donaueschingenstrasse 13, 1200, Vienna, Austria
| | - T Hausner
- AUVA Trauma Hospital Lorenz Böhler, European Hand Trauma Center, Donaueschingenstrasse 13, 1200, Vienna, Austria.,Ludwig Boltzmann Institute for Experimental Und Clinical Traumatology, AUVA Research Center, 1200, Vienna, Austria.,Austrian Cluster for Tissue Regeneration, Vienna, Austria.,Department for Orthopedic Surgery and Traumatology, Paracelsus Medical University, 5020, Salzburg, Austria
| | - M Leixnering
- AUVA Trauma Hospital Lorenz Böhler, European Hand Trauma Center, Donaueschingenstrasse 13, 1200, Vienna, Austria
| |
Collapse
|
3
|
Abstract
In the recent years, treatment of distal radius fractures (DRF) has advanced considerably. Surgical fixation with palmar angular stable plate has gained popularity, due to a reported lower complication rate when compared to dorsal fixation. The type of trauma or injury, surgical procedure and impaired bone quality are all contributors to complications in DRF. The main aim of this review is to summarize the most common complications and possible therapeutic solutions. In addition, strategies for minimizing these complications will be discussed.
Collapse
|
4
|
Inducing life-like distal radius fractures in human cadaveric specimens: a tool for enhanced surgical training. Arch Orthop Trauma Surg 2020; 140:425-432. [PMID: 31807851 DOI: 10.1007/s00402-019-03313-5] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/27/2019] [Indexed: 10/25/2022]
Abstract
INTRODUCTION Surgical education consists often times of a discrepancy between necessary amount of provided operative teaching and amount of organizational and ward duties. Operative education is often cut to a minimum. As public awareness toward surgical competence raises, so must the educational system. Courses that provide pre-fractured cadaveric specimens can facilitate surgical teaching realistically, prior to operating on living patients. The aim of this study is to introduce a realistic distal radius fracture simulation setup. MATERIALS AND METHODS 12 cadaveric specimens (3 male, 9 female) were fixed onto a custom drop-test-bench in the hyperextension of the wrist. The forearm was cut midway between elbow and carpus. The distal part of the forearm was potted, and the specimen was exposed to a high energetic impulse. CT imaging was performed after fracture simulation to detect the exact fracture patterns. We used the AO/ASIF recommendations and four-corner concept to classify the achieved fractures by two independent trauma surgeons. RESULTS All cadaveric specimens could be successfully fractured. 11 fractures were classified as type 23C3.2 and one was classified as type 23C3.3, as additional fracture of diaphysis occurred. Subclassification according to the four-corner concept showed all fractures to be type C. A concomitant ulnar styloid fracture was observed in 4 cases. Furthermore, all cases showed at least one fragment involving the sigmoid notch. There was no statistically significant correlation found regarding Hounsfield Units (HU) and age (p value 0.402), as well as HU and required kinetic energy (p value 0.063). CONCLUSION A high energetic impulse induced by a custom-made drop-test bench can successfully simulate realistic distal radius fractures in cadaveric specimens with intact soft tissue. Furthermore, these pre-fractured specimens can be utilized in surgical education to provide a teaching experience as realistic as possible without harming living patients.
Collapse
|
5
|
Hintringer W, Rosenauer R, Pezzei C, Quadlbauer S, Jurkowitsch J, Keuchel T, Hausner T, Leixnering M, Krimmer H. Biomechanical considerations on a CT-based treatment-oriented classification in radius fractures. Arch Orthop Trauma Surg 2020; 140:595-609. [PMID: 32193681 PMCID: PMC7181558 DOI: 10.1007/s00402-020-03405-7] [Citation(s) in RCA: 27] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/03/2020] [Indexed: 12/14/2022]
Abstract
A wide range of different classifications exist for distal radius fractures (DRF). Most of them are based on plane X-rays and do not give us any information on how to treat these fractures. A biomechanical understanding of the mechanical forces underlying each fracture type is important to treat each injury specifically and ensure the optimal choice for stabilization. The main cause of DRFs are forces acting on the carpus and the radius as well as the position of the wrist in relation to the radius. Reconstructing the mechanism of the injury gives insight into which structures are involved, such as ruptured ligaments, bone fragments as well as the dislocated osteoligamentous units. This article attempts to define certain key fragments, which seem crucial to reduce and stabilize each type of DRF. Once the definition is established, an ideal implant can be selected to sufficiently maintain reduction of these key fragments. Additionally, the perfect approach is selected. By applying the following principles, the surgeon may be assisted in choosing the ideal form of treatment approach and implant selection.
Collapse
Affiliation(s)
- W. Hintringer
- PK Döbling, Heiligenstädter Strasse 55-63, 1190 Vienna, Austria
| | - R. Rosenauer
- grid.420022.60000 0001 0723 5126AUVA Trauma Hospital Lorenz Böhler, European Hand Trauma Center, Donaueschingenstrasse 13, 1200 Vienna, Austria ,grid.420022.60000 0001 0723 5126Ludwig Boltzmann Institute for Experimental and Clinical Traumatology, AUVA Research Center, Donaueschingenstrasse 13, 1200 Vienna, Austria ,Austrian Cluster for Tissue Regeneration, 1200 Vienna, Austria
| | - Ch. Pezzei
- grid.420022.60000 0001 0723 5126AUVA Trauma Hospital Lorenz Böhler, European Hand Trauma Center, Donaueschingenstrasse 13, 1200 Vienna, Austria
| | - S. Quadlbauer
- grid.420022.60000 0001 0723 5126AUVA Trauma Hospital Lorenz Böhler, European Hand Trauma Center, Donaueschingenstrasse 13, 1200 Vienna, Austria ,grid.420022.60000 0001 0723 5126Ludwig Boltzmann Institute for Experimental and Clinical Traumatology, AUVA Research Center, Donaueschingenstrasse 13, 1200 Vienna, Austria ,Austrian Cluster for Tissue Regeneration, 1200 Vienna, Austria
| | - J. Jurkowitsch
- grid.420022.60000 0001 0723 5126AUVA Trauma Hospital Lorenz Böhler, European Hand Trauma Center, Donaueschingenstrasse 13, 1200 Vienna, Austria
| | - T. Keuchel
- grid.420022.60000 0001 0723 5126AUVA Trauma Hospital Lorenz Böhler, European Hand Trauma Center, Donaueschingenstrasse 13, 1200 Vienna, Austria
| | - T. Hausner
- grid.420022.60000 0001 0723 5126AUVA Trauma Hospital Lorenz Böhler, European Hand Trauma Center, Donaueschingenstrasse 13, 1200 Vienna, Austria ,grid.420022.60000 0001 0723 5126Ludwig Boltzmann Institute for Experimental and Clinical Traumatology, AUVA Research Center, Donaueschingenstrasse 13, 1200 Vienna, Austria ,Austrian Cluster for Tissue Regeneration, 1200 Vienna, Austria ,grid.21604.310000 0004 0523 5263Department for Orthopedic Surgery and Traumatology, Paracelsus Medical University, Strubergasse 21, 5020 Salzburg, Austria
| | - M. Leixnering
- grid.420022.60000 0001 0723 5126AUVA Trauma Hospital Lorenz Böhler, European Hand Trauma Center, Donaueschingenstrasse 13, 1200 Vienna, Austria
| | - H. Krimmer
- Hand Center Ravensburg, Elisabethenstraße 19, 88212 Ravensburg, Germany
| |
Collapse
|
6
|
Donor site complications following anterior iliac crest bone graft for treatment of distal radius fractures. Arch Orthop Trauma Surg 2019; 139:423-428. [PMID: 30542762 DOI: 10.1007/s00402-018-3098-3] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/26/2018] [Indexed: 10/27/2022]
Abstract
INTRODUCTION In distal radius fractures with metaphyseal comminution, bone grafting or the use of a bone substitute may be necessary. Harvesting autologous iliac crest bone graft for other orthopedic procedures has complications. The aim of this study was to evaluate the complication rate after harvesting a small amount of bone as used for the treatment of radius fractures. PATIENTS AND METHODS Patients treated in a single level I trauma center with surgical treatment for distal radius fracture with iliac crest bone graft between January 2008 and December 2012 were included in this retrospective study. Patients' records were evaluated and clinical evaluation was performed at follow-up. RESULTS 42 patients (20 females, 22 males, mean age 56.3 ± 15.9 years) were included in this study. Follow-up was mean 6.3 ± 1.2 years. Only minor complications such as hematoma could be identified; in one patient, revision surgery for bleeding was performed. No nerve injuries, long-term pain, fractures, infections or wound healing disturbances could be seen. The use of a drain of hemostyptics, the type of wound closure or pattern of harvested bone did not influence complication rate. CONCLUSION This study shows that harvesting a small amount of iliac crest bone graft for the treatment of distal radius fractures is a safe procedure with a very low complication rate.
Collapse
|
7
|
Three-dimensional kinematics of the flexor pollicis longus tendon in relation to the position of the FPL plate and distal radius width. Arch Orthop Trauma Surg 2019; 139:269-279. [PMID: 30506496 DOI: 10.1007/s00402-018-3081-z] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/15/2018] [Indexed: 02/09/2023]
Abstract
INTRODUCTION The standard therapy of intra-articular and extra-articular distal radius fractures consists of open reduction and stabilization using palmar osteosynthesis with an angularly stable plate. The integrity of the flexor pollicis longus tendon (FPLT) may be mechanically affected by the plate, with rupture rates between 1 and 12% reported in the literature, occurring during a postoperative time period from 4 to 120 months. The aim of this study was to investigate the position of the tendon in relation to the distal edge of the plate using high-resolution ultrasonic imaging. MATERIALS AND METHODS Nineteen patients undergoing osteosynthesis for distal radius fracture in 2015 with the Medartis® APTUS® FPL plate were included in this study. Of these, seven dropped out for various reasons. Therefore, twelve patients with a median age of 52 years (range 24-82 years) were included in the final analysis. High-frequency ultrasound was performed within a median of 28 (range 10-52) weeks by an experienced radiology specialist to locate the FPLT position in two separate wrist positions: (1) wrist held in 0° position and fingers extended and (2) wrist held in 45° of dorsal extension and actively flexed fingers II to V (functional position). For analysis, we used the axial ultrasound videos. Postoperative X-rays and CT scans were included for the analysis, especially the soft-tissue CT scan window for the exact localization of the FPLT. Dynamic ultrasound scanning was used to localize the FPLT in relation to the plate in 0° and functional position of the hand. Using CT scanning, the position of the plate relative to the bone was determined. In this way, we were able to correlate the functional FPLT position with the osseous structures of the distal radius. RESULTS In all cases, the FPLT was positioned closer to the volar distal edge of the FPL plate in functional position than in 0° position. In four cases, the FPLT did not touch the plate at all and was shown to shift diagonally from radio-volar in ulno-dorsal direction during wrist movement from 0° to functional position, similarly to the sliding of the tendon in the assumed physiological motion sequence. In these cases, in the functional position the center of the FPLT was positioned slightly ulnarly of the center of the distal radius (i.e., less than 50% of the distal radius width measured from the radial border of DRUJ), and positioned more ulnarly than in all other cases (i.e., in which the FPLT came into contact with the plate). In the remaining two-thirds of the cases (eight patients), the FPLT touched the plate during wrist movement from 0° to functional position, shifted in dorsal direction and slid into the plate indentation, irrespective of whether the tendon entered the indentation from the radial or the ulnar side, and independent of the ulnoradial position of the plate. No signs of tendinopathy of the FPLT were found in any of the cases. CONCLUSION The results show that the indentation of the Medartis® APTUS® FPL plate reduces the tendon-plate contact and ideally even prevents it entirely. In particular, ulnar positioning of the plate lowers the risk of tendon-plate contact. If the FPLT touches the plate, the tendon pulls into the plate indentation, thus lowering the contact. Consequently, the Soong criteria are not applicable when a FPL plate is used.
Collapse
|
8
|
Giordano V, Pires RES, Pesántez R, Kojima K, Koch HA. Expanding the Indications for Mini Plates in the Orthopedic Trauma Scenario: A Useful Alternative Technique for Maintaining Provisional Reduction and Improving Stability for Complex Periarticular Fracture Fixation of the Upper Limbs. J Orthop Case Rep 2018; 8:42-46. [PMID: 30584514 PMCID: PMC6298715 DOI: 10.13107/jocr.2250-0685.1100] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
Introduction The use of mini plates as a reduction tool is an elegant technique for temporary stabilization of multifragmentary fractures. For some complex periarticular fractures with severe comminution close to the articular surface, mini plates seem to be a better option than K-wires for provisional as well as definitive fixation, because of the presence of small fragments and proximity to the joint increases the risk of additional fragmentation and articular penetration, respectively. Case Report Five cases of complex periarticular fractures of the upper limb are presented. We used 2.3 mm mini plates as reduction plates for different situations, including one scapula fracture, one clavicle fracture, one distal humerus fracture, one proximal ulna fracture, and one distal radius fracture. In all cases, an excellent clinical outcome with a full return to pain-free activity was achieved after a minimum follow-up of 12 months. Conclusion We feel that these mini extra-articular implants are particularly helpful as temporary reduction tools before the application of the definitive implant to a reduced and stabilized the fracture. Because they have longer screws allowing better cortical purchase and low-profile allowing plate overlap, the procedure seems to be faster and easier when compared to the use of temporary K-wires and clamps.
Collapse
Affiliation(s)
- Vincenzo Giordano
- Serviço de Ortopedia e Traumatologia Prof. Nova Monteiro, Hospital Municipal Miguel Couto, Rio de Janeiro, Brazil.,Clínica São Vicente, Rio de Janeiro, Brazil
| | | | - Rodrigo Pesántez
- Departamento de Ortopedia, Universidad de los Andes, Bogotá, Colombia
| | - Kodi Kojima
- Instituto de Ortopedia e Traumatologia, Universidade de São Paulo, São Paulo, Brazil
| | | |
Collapse
|
9
|
Early complications and radiological outcome after distal radius fractures stabilized by volar angular stable locking plate. Arch Orthop Trauma Surg 2018; 138:1773-1782. [PMID: 30341694 DOI: 10.1007/s00402-018-3051-5] [Citation(s) in RCA: 39] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/20/2018] [Indexed: 12/31/2022]
Abstract
INTRODUCTION Distal radius fractures (DRF) are the most common fractures of the upper extremities. The incidence is expected to continue rising in the next years due to the increased life expectancy. Palmar locking plate stabilizing has since become the standard treatment for dorsally displaced DRF with a complication rate of 8-39% reported in the literature. Main aim of this study was to investigate the incidence of complications after DRF stabilization using palmar angular stable locking plate. METHODS A retrospective medical records review conducted from January 2013 to December 2016 included a total of 392 patients with DRF, that were stabilized using palmar angular stable locking plate and showed a minimum follow-up of 3 months. The group comprised 259 female and 133 male patients with a mean follow-up interval of 11 months (range 3-52 months). All recorded complications were documented. Range of motion (ROM) in extension, flexion, supination, pronation, radial- and ulnar deviation of the last follow-up was noted. Age was divided into younger than 65 years (< 65 years) and older than 65 years (≥ 65 years). The primary, immediate postoperative and final checkup radiographs were scrutinized for alignment and intra-articular step-off. RESULTS A total of 51 (13%) early and 17 late (4%) complications were recorded in 392 patients. The most common complications included carpal tunnel syndrome (3%), complex regional pain syndrome (3%) and loss of reduction (2%). Of the 68 complications, only 25 (6%) were directly related to the plate. 73% of all complications occurred in AO type C fractures. Patients without complications showed a significantly better ROM in extension, flexion, pronation and supination than patients with complications. No significant differences in incidence of complications, ROM or loss of reduction could be found between patients over and under 65 years of age. Gender and type of immobilization showed no significant influence on the complication rate. CONCLUSIONS Stabilization of DRF by palmar angular stable locking plate is a safe form of treatment. In the majority of the cases a good clinical and radiological outcome with no complications was documented. Gender and type of immobilization had no impact on the complication rate and an age over 65 years is not associated with an increased risk for complications or restricted ROM.
Collapse
|
10
|
Babst R, Beeres FJP, Link BC. [Definitions and explanations on the topic of fracture reduction]. Unfallchirurg 2018; 122:88-94. [PMID: 30402688 DOI: 10.1007/s00113-018-0573-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
The process of reduction is a key step for successful fracture treatment. The goal of fracture reduction is the realignment of the displaced fractured fragments caused by muscle tension or impaction back into the original anatomic relationship. The reduction process includes not only the application of force at or remote from the fracture site to reverse the deforming forces but also the preoperative planning where to apply these forces and by what means. Furthermore, consideration should be preoperatively given on how to position the patient and the C‑arm and how to temporarily maintain reduction for intraoperative x‑ray control of the axis, rotation and lengths before definitive fixation.
Collapse
Affiliation(s)
- R Babst
- Fachbereich Unfallchirurgie, Klinik für Orthopädie und Unfallchirurgie, Luzerner Kantonsspital, 6003, Luzern, Schweiz.
| | - F J P Beeres
- Klinik für Orthopädie und Unfallchirurgie, Luzerner Kantonsspital, Luzern, Schweiz
| | - B-C Link
- Klinik für Orthopädie und Unfallchirurgie, Luzerner Kantonsspital, Luzern, Schweiz
| |
Collapse
|
11
|
Hohendorff B, Knappwerth C, Franke J, Müller LP, Ries C. Pronator quadratus repair with a part of the brachioradialis muscle insertion in volar plate fixation of distal radius fractures: a prospective randomised trial. Arch Orthop Trauma Surg 2018; 138:1479-1485. [PMID: 30062458 DOI: 10.1007/s00402-018-2999-5] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/25/2018] [Indexed: 11/25/2022]
Abstract
INTRODUCTION Stable pronator quadratus repair following volar plate fixation of distal radius fractures with complete plate coverage is difficult. MATERIALS AND METHODS This study compares a modified pronator quadratus repair technique involving the brachioradialis muscle insertion (test group) with a conventional radial incision through the muscle without pronator quadratus repair (standard group). This prospective randomised study included 16 patients in the test group and 12 in the standard group; all were available for clinical, radiographic and ultrasound examination at a mean follow-up of 15 months. RESULTS Pronator quadratus repair was feasible in all test group patients, and complete coverage of the distal plate was achieved in 11. No differences in functional outcome were observed between the groups. CONCLUSION Pronator quadratus repair with a part of the brachioradialis muscle insertion is a reliable technique for coverage of a volar plate by slight distal transposition. In the repair of distal radius fractures, this may better protect the finger flexor tendons against irritation and/or rupture. That likelihood should now be studied.
Collapse
Affiliation(s)
- Bernd Hohendorff
- Abteilung für Hand-, Ästhetische und Plastische Chirurgie, Elbe Klinikum Stade, Stade, Germany.
| | - C Knappwerth
- Klinik für Unfallchirurgie und Orthopädie, Elbe Klinikum Stade, Stade, Germany
| | - J Franke
- Klinik für Unfallchirurgie und Orthopädie, Elbe Klinikum Stade, Stade, Germany
| | - L P Müller
- Unfall-, Hand- und Ellenbogenchirurgie, Klinik und Poliklinik für Orthopädie und Unfallchirurgie, Universitätsklinikum zu Köln, Cologne, Germany
| | - C Ries
- Unfall-, Hand- und Ellenbogenchirurgie, Klinik und Poliklinik für Orthopädie und Unfallchirurgie, Universitätsklinikum zu Köln, Cologne, Germany
| |
Collapse
|