1
|
Briotti J, Wilson S, Goh G, Lawson-Smith M. Wrist Arthrodesis Using the Medartis Carpometacarpal Joint Sparing Plate. Hand (N Y) 2024; 19:607-613. [PMID: 36541766 PMCID: PMC11141422 DOI: 10.1177/15589447221141474] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
BACKGROUND Total wrist arthrodesis is a well-established surgical technique that provides reliable pain relief in patients with advanced wrist disease. Key limitations of existing plating systems include hardware pull-out, hardware failure, and nonunion. There is limited literature on the newer style carpometacarpal joint (CMCJ) sparing plating system, produced by Medartis. The objective of this study was to determine the long-term clinical and radiological outcomes of wrist arthrodesis with a CMCJ sparing wrist plate. METHODS This study retrospectively identified 23 wrist arthrodeses using the Medartis CMCJ sparing plate for review. This study assessed the outcomes of 18 unilateral wrist fusions and 1 bilateral wrist fusion. The study group consisted of 12 men and 5 women with an average age of 56 years (range: 29-82 years) with a mean follow-up period of 17 months. RESULTS At the time of follow-up, all patients' wrists had fused without postsurgical complication. The final grip strength in the operative hand was 28.2 kg/cm2, which was 87% of the contralateral side. The mean Quick Disabilities of the Arm, Shoulder, and Hand score at follow-up was 23.9, with all patients returning to daily living activities and work. Patients reported minimal pain (1.3/10), with almost all (17/18) satisfied with the outcome of the surgery and describing that they would recommend this procedure. CONCLUSION Our case series highlights that the Medartis wrist arthrodesis plate is a newer design that is a well-tolerated option for wrist arthrodesis based on clinical assessment, functional hand assessment, and patient satisfaction, when compared with the existing literature on traditional plating systems.
Collapse
Affiliation(s)
- Joshua Briotti
- Royal Perth Hospital, WA, Australia
- University of Notre Dame Australia, Fremantle, WA, Australia
| | | | | | - Matthew Lawson-Smith
- University of Notre Dame Australia, Fremantle, WA, Australia
- Fremantle Hospital, WA, Australia
| |
Collapse
|
2
|
Knie C, van Schoonhoven J. Long-term results after total wrist fusion. Arch Orthop Trauma Surg 2023; 143:6469-6475. [PMID: 37344687 DOI: 10.1007/s00402-023-04938-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/12/2023] [Accepted: 05/25/2023] [Indexed: 06/23/2023]
Abstract
Sixty-eight patients with seventy-one total wrist fusions were retrospectively reviewed with a mean follow-up of 11.7 years. The main purpose of this study was to determine long-term functional results and define possible reasons for remaining pain. Except one asymptomatic non-union, all wrist fusions united. The long-term functional result averaged 30 points using the DASH score and appears to be more favorable compared to midterm results in another publication from this department. Only 15 patients were completely free of pain. Most patients complained about remaining pain during strong activities with a mean VAS of 4/10 that could not further been defined on clinical or radiological examinations. Patients with more than two previous operations had a significant worse outcome concerning the modified Mayo wrist score [≤ 1 operation mean 61 points vs. ≥ 2 operations mean 56 points (Mann-Whitney U test: p = 0.009)] and PRWE-G [≤ 1 operation mean 27 points vs. ≥ 2 operations mean 37 points (t test: p = 0.047)] and furthermore a downward trend for worse DASH [≤ 1 operation mean 265 points vs. ≥ 2 operations mean 35 points (t test: p = 0.086)] results. Despite the loss of wrist motion and remaining pain, patients were highly satisfied with the long-term result and 93% would undergo the operation again.
Collapse
Affiliation(s)
- C Knie
- Clinic for Hand Surgery, Rhön-Klinikum, Von-Guttenberg-Straße11, 97616, Bad Neustadt a.d. Saale, Germany.
| | - J van Schoonhoven
- Clinic for Hand Surgery, Rhön-Klinikum, Von-Guttenberg-Straße11, 97616, Bad Neustadt a.d. Saale, Germany
| |
Collapse
|
3
|
Damert HG, Kober M, Mehling I. Custom-made wrist prothesis (UNI-2™) in a patient with giant cell tumor of the distal radius: 10-year follow-up. Arch Orthop Trauma Surg 2020; 140:2109-2114. [PMID: 32876750 DOI: 10.1007/s00402-020-03593-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/10/2020] [Accepted: 08/16/2020] [Indexed: 11/28/2022]
Abstract
Wrist endoprosthesis is still an exceptional indication compared to the prosthesis of large joints, especially when a rescue surgery procedure of the wrist is no longer possible and the complete wrist arthrodesis is to be considered the ultima ratio. However, a suspended function in the wrist is accompanied by a significant restriction in the patient`s daily life. Using the fourth-generation endoprosthesis, the situation regarding long-term results for the hand has already improved. This means that a durability of more than 6 years is no longer a rarity. Defect situations in joints, in particular those which occur after tumor, still pose a greater challenge. If autologous reconstructions cannot be performed, custom-made prostheses can be considered as very rare indications for joint reconstruction. While these have been used for years on large joints such as shoulder, elbow, knee and hip, they have only been described on the hand in particular cases. We report the 10-year follow-up of implantation of a custom-made wrist prothesis (UNI-2™, KMI, Germany) in a 36-year-old patient with tumorous destruction of the distal radius by a giant cell tumor.
Collapse
Affiliation(s)
- H G Damert
- Klinik für Plastische, Ästhetische und Handchirurgie, HELIOS-Bördeklinik, Kreiskrankenhaus 4, 39387, Oschersleben, Germany.
| | - M Kober
- Klinik für Plastische, Ästhetische und Handchirurgie, HELIOS-Bördeklinik, Kreiskrankenhaus 4, 39387, Oschersleben, Germany
| | - I Mehling
- St. Vinzenz-Krankenkaus Hanau gGmbH, Am Frankfurter Tor 25, 63450, Hanau, Germany
| |
Collapse
|
4
|
Spies CK, Ayache A, Löw S, Langer MF, Hohendorff B, Müller LP, Oppermann J, Unglaub F. [Revision surgery after failed (partial-) arthrodesis of the wrist]. DER ORTHOPADE 2020; 49:784-796. [PMID: 32809041 DOI: 10.1007/s00132-020-03967-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
(Partial) arthrodeses of the wrist have been proven cornerstones to treat many lesions for decades, especially in the case of revision surgery. Four-corner, scapho-trapezo-trapezoidal (STT), radio-scapho-lunate (RSL) and total wrist fusions are very common techniques in hand surgery. However, even these proven surgical procedures have significant non-fusion rates. Prior to revising a failed arthrodesis, it is essential to analyse the latter failure precisely. A technically adequate revision is only feasible when based on a correct and meticulous analysis. The understanding of the biological processes and technical aspects of the implants are the basis for solving this issue.
Collapse
Affiliation(s)
- C K Spies
- Handchirurgie, Vulpius Klinik, Vulpiusstraße 29, 74906, Bad Rappenau, Deutschland.
| | - A Ayache
- Handchirurgie, Vulpius Klinik, Vulpiusstraße 29, 74906, Bad Rappenau, Deutschland
| | - S Löw
- Praxis für Handchirurgie und Unfallchirurgie, Bad Mergentheim, Deutschland
| | - M F Langer
- Klinik für Unfall‑, Hand- und Wiederherstellungschirurgie, Universitätsklinikum Münster, Münster, Deutschland
| | - B Hohendorff
- Abteilung für Hand‑, Ästhetische und Plastische Chirurgie, Elbe Klinikum Stade, Stade, Deutschland
| | - L P Müller
- Klinik und Poliklinik für Orthopädie und Unfallchirurgie, Universitätsklinikum Köln, Köln, Deutschland
| | - J Oppermann
- Klinik und Poliklinik für Orthopädie und Unfallchirurgie, Universitätsklinikum Köln, Köln, Deutschland
| | - F Unglaub
- Handchirurgie, Vulpius Klinik, Vulpiusstraße 29, 74906, Bad Rappenau, Deutschland.,Medizinische Fakultät Mannheim, Universität Heidelberg, Mannheim, Deutschland
| |
Collapse
|
5
|
Damert HG, Kober M, Mehling I. [Revision surgery after total wrist arthroplasty]. DER ORTHOPADE 2020; 49:797-807. [PMID: 32776275 DOI: 10.1007/s00132-020-03968-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
BACKGROUND Wrist arthroplasty is still an exceptional indication in the field of hand surgery. In recent years, it has become increasingly accepted as an alternative to wrist arthrodesis as the ultima ratio for panarthrosis or similar destruction of the wrist. In particular, the patient's desire for functional integrity also plays an important role. COMPLICATIONS While there were often complications with earlier prosthesis designs of the older generations and only a short survival rate could be achieved, this has improved, if the indication of the so-called fourth generation prostheses is done properly. Survival rates of over 10 years are no longer uncommon, even without revision operations. Currently, the indication for hemiarthroplasty has been increasing, particularly in the case of post-traumatic destruction. Those who are seriously interested in endoprosthesis should also be able to treat the associated complications. The present article is intended to provide an overview of common or potential complications in the context of wrist arthroplasty and to demonstrate possible solutions by presenting case studies. The basics of primary implantation are, therefore, not discussed. Reference is made to further literature.
Collapse
Affiliation(s)
- H-G Damert
- Klinik für Plastische, Ästhetische und Handchirurgie, HELIOS Bördeklinik GmbH, Kreiskrankenhaus 4, 39387, Oschersleben (Bode)/Neindorf, Deutschland.
| | - M Kober
- Klinik für Plastische, Ästhetische und Handchirurgie, HELIOS Bördeklinik GmbH, Kreiskrankenhaus 4, 39387, Oschersleben (Bode)/Neindorf, Deutschland
| | - I Mehling
- Sektion Handchirurgie, St. Vinzenz-Krankenhaus Hanau gGmbH, Hanau, Deutschland
| |
Collapse
|
6
|
Keuchel-Strobl T, Quadlbauer S, Jurkowitsch J, Rosenauer R, Hausner T, Leixnering M, Pezzei C. Salvage procedure after malunited distal radius fractures and management of pain and stiffness. Arch Orthop Trauma Surg 2020; 140:697-705. [PMID: 32193673 DOI: 10.1007/s00402-020-03369-8] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/03/2020] [Indexed: 12/28/2022]
Abstract
Indications for surgical treatment of distal radius fractures (DRF) remain controversial in the literature, especially in elderly patients. Complication rates after operatively treated DRF are low and well documented. These include malunion, degenerative osteoarthritis in the radiocarpal joint and subsequently pain and impaired hand function. If conservative treatment fails then salvage procedures are necessary. This review summarizes the therapeutic options available to treat degenerative osteoarthritis after malunited distal radius fractures, regardless of the initial operative or conservative treatment.
Collapse
Affiliation(s)
- Tina Keuchel-Strobl
- AUVA Trauma Hospital Lorenz Böhler - European Hand Trauma Center, Donaueschingenstrasse 13, 1200, Vienna, Austria.
| | - S Quadlbauer
- AUVA Trauma Hospital Lorenz Böhler - European Hand Trauma Center, Donaueschingenstrasse 13, 1200, Vienna, Austria.,Ludwig Boltzmann Institute for Experimental und Clinical Traumatology, AUVA Research Center, 1200, Vienna, Austria.,Austrian Cluster for Tissue Regeneration, 1200, Vienna, Austria
| | - J Jurkowitsch
- AUVA Trauma Hospital Lorenz Böhler - European Hand Trauma Center, Donaueschingenstrasse 13, 1200, Vienna, Austria
| | - R Rosenauer
- AUVA Trauma Hospital Lorenz Böhler - European Hand Trauma Center, Donaueschingenstrasse 13, 1200, Vienna, Austria.,Ludwig Boltzmann Institute for Experimental und Clinical Traumatology, AUVA Research Center, 1200, Vienna, Austria.,Austrian Cluster for Tissue Regeneration, 1200, Vienna, Austria
| | - T Hausner
- AUVA Trauma Hospital Lorenz Böhler - European Hand Trauma Center, Donaueschingenstrasse 13, 1200, Vienna, Austria.,Ludwig Boltzmann Institute for Experimental und Clinical Traumatology, AUVA Research Center, 1200, Vienna, Austria.,Austrian Cluster for Tissue Regeneration, 1200, Vienna, Austria.,Department for Orthopedic Surgery and Traumatology, Paracelsus Medical University, 5020, Salzburg, Austria
| | - M Leixnering
- AUVA Trauma Hospital Lorenz Böhler - European Hand Trauma Center, Donaueschingenstrasse 13, 1200, Vienna, Austria
| | - Ch Pezzei
- AUVA Trauma Hospital Lorenz Böhler - European Hand Trauma Center, Donaueschingenstrasse 13, 1200, Vienna, Austria
| |
Collapse
|
7
|
Low-profile locking-plate vs. the conventional AO system: early comparative results in wrist arthrodesis. Arch Orthop Trauma Surg 2020; 140:433-439. [PMID: 31811374 DOI: 10.1007/s00402-019-03314-4] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/23/2019] [Indexed: 02/09/2023]
Abstract
INTRODUCTION Total wrist arthrodesis represents a reliable salvage procedure for severe painful conditions of the wrist. To date, wrist arthrodesis using a dorsal plate reaching from the distal radius to the third metacarpal is still recommended. A new implant (APTUS© 2.5 TriLock Wrist Fusion Plate, Medartis Suisse) that does not cross the third carpometacarpal joint (CMCJ-3) has been introduced recently. The purpose of this retrospective study was to compare both implants concerning early functional and clinical results. MATERIALS AND METHODS A total of 20 patients underwent total wrist arthrodesis [10, using the new APTUS© implant (APT); 10 using the Depuy-Synthes© LCP plates (AO)]. The postoperative control interval was 18.2 and 37.2 months in APT and AO, respectively. Clinical assessment included functional parameters such as active range of motion (AROM) for pronation and supination, grip strength, and passive range of motion of the CMCJ-3. Additionally the DASH score and the Krimmer wrist score as well as pain levels at rest and under stress conditions were evaluated. RESULTS All patients showed osseous healing without complications except one case of non-union in APT. There were no significant differences between both groups concerning grip strength, AROM of the wrist, pain levels, DASH- and Krimmer Score. APT showed a significantly increased passive range of motion of the CMCJ-3 compared to the unaffected contralateral side. CONCLUSIONS The new implant shows similar functional results compared to the standard procedure. The main advantage of the new implant is the fact that no implant removal is necessary due to the unaffected CMCJ-3. Furthermore the mobility of the CMCJ slightly increased and showed positive impact on hand kinematics.
Collapse
|
8
|
[Palmar radioscapholunate arthrodesis with distal scaphoidectomy]. OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE 2020; 32:455-466. [PMID: 32100069 DOI: 10.1007/s00064-020-00651-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/21/2019] [Revised: 07/19/2019] [Accepted: 07/22/2019] [Indexed: 10/24/2022]
Abstract
OBJECTIVE Radioscapholunate (RSL) arthrodesis with distal scaphoidectomy using an angular stable plate and palmar access in post-traumatic or degenerative osteoarthritis limited to the radiocarpal joint. INDICATIONS Osteoarthritis limited to the radiocarpal joint with intact mediocarpal joint after malunited intra-articular distal radius fractures, rheumatoid osteoarthritis, scapholunate advanced collapse (SLAC) up to stage II. CONTRAINDICATIONS Mediocarpal osteoarthritis, poor patient compliance, SLAC from stage III, osteitis. SURGICAL TECHNIQUE The palmar RSL arthrodesis is performed using the palmar approach between the flexor carpi radialis tendon and the radial artery. After releasing the pronator quadratus muscle, a longitudinal capsulotomy is performed and the radiocarpal joint is inspected. After correction of a volar or dorsal intercalated segmental instability of the lunate, the lunate is temporarily fixed to the scaphoid using a K-wire. The distal quarter of the scaphoid and the palmar rim of the distal radius is resected and the cartilage between the scaphoid, lunate and distal radius is removed. The scaphoid and lunate are temporarily fixed to the distal radius using K‑wires. Under image intensifier control the angular stable low-profile plate (e.g., volar 2.5 Trilock RSL Fusion plate [Medartis® Aptus® Basel, Switzerland]) is fixed to the distal radius in the long-leg hole. The scaphoid and lunate are fixed distally with two screws each. The carpus is pushed distally using a Codeman distractor and the cancellous bone graft is impacted. Finally, the shaft is fixed with angular stable screws. POSTOPERATIVE MANAGEMENT Immobilization using a plaster cast or thermoplastic short-arm orthosis for 5 weeks. After 2 weeks, the orthosis can be removed during hand therapy with active wrist and finger exercises. Normal activities permitted after 12 weeks. RESULTS Palmar RSL arthrodesis and distal scaphoidectomy using angular stable plate fixation shows a high union rate and pain relief while maintaining good residual mobility of the wrist.
Collapse
|
9
|
Abstract
BACKGROUND Total wrist arthroplasty is still a rare procedure. This issue is being discussed controversially, particular in German-speaking countries. Lately, its acceptance has risen, especially as an alternative to wrist fusion regarding treatment of panarthritis or similar pathologies. Previous arthroplasty designs had short survival spans and devastating complications. THE CURRENT SITUATION Currently, these problems have been reduced by the development of fourth generation arthroplasty systems. Nowadays, survival spans of 10 years and more can be seen on a regular basis. The development of hemi-arthroplasty may be of interest, especially for traumatic destruction of the distal radius. This review outlines the current state of wrist arthroplasty and is based on the author's 15 years of experience.
Collapse
|
10
|
Meier R. [Treatment options for scaphoid nonunion advanced collapse]. Unfallchirurg 2019; 122:211-218. [PMID: 30887083 DOI: 10.1007/s00113-019-0631-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
Untreated scaphoid nonunion as a rule results in subsequent scaphoid nonunion advanced collapse (SNAC) wrist. While reconstructive treatment of the scaphoid in association with resection of the styloid process of the radius is still promising in stage I SNAC wrist, salvage procedures are available for higher degrees of SNAC wrist to reduce pain and to preserve the function of the wrist. Denervation, proximal row carpectomy and partial wrist fusion maintain wrist mobility. Total wrist arthrodesis and total wrist arthroplasty are salvage procedures in cases of panarthritis or failed motion-preserving procedures.
Collapse
Affiliation(s)
- R Meier
- Unfall‑, Hand und Wiederherstellungschirurgie, Helios Klinikum Meiningen, Akademisches Lehrkrankenhaus des Universitätsklinikums Jena, Bergstr. 3, 98617, Meiningen, Deutschland.
| |
Collapse
|
11
|
Early complications and radiological outcome after distal radius fractures stabilized by volar angular stable locking plate. Arch Orthop Trauma Surg 2018; 138:1773-1782. [PMID: 30341694 DOI: 10.1007/s00402-018-3051-5] [Citation(s) in RCA: 39] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/20/2018] [Indexed: 12/31/2022]
Abstract
INTRODUCTION Distal radius fractures (DRF) are the most common fractures of the upper extremities. The incidence is expected to continue rising in the next years due to the increased life expectancy. Palmar locking plate stabilizing has since become the standard treatment for dorsally displaced DRF with a complication rate of 8-39% reported in the literature. Main aim of this study was to investigate the incidence of complications after DRF stabilization using palmar angular stable locking plate. METHODS A retrospective medical records review conducted from January 2013 to December 2016 included a total of 392 patients with DRF, that were stabilized using palmar angular stable locking plate and showed a minimum follow-up of 3 months. The group comprised 259 female and 133 male patients with a mean follow-up interval of 11 months (range 3-52 months). All recorded complications were documented. Range of motion (ROM) in extension, flexion, supination, pronation, radial- and ulnar deviation of the last follow-up was noted. Age was divided into younger than 65 years (< 65 years) and older than 65 years (≥ 65 years). The primary, immediate postoperative and final checkup radiographs were scrutinized for alignment and intra-articular step-off. RESULTS A total of 51 (13%) early and 17 late (4%) complications were recorded in 392 patients. The most common complications included carpal tunnel syndrome (3%), complex regional pain syndrome (3%) and loss of reduction (2%). Of the 68 complications, only 25 (6%) were directly related to the plate. 73% of all complications occurred in AO type C fractures. Patients without complications showed a significantly better ROM in extension, flexion, pronation and supination than patients with complications. No significant differences in incidence of complications, ROM or loss of reduction could be found between patients over and under 65 years of age. Gender and type of immobilization showed no significant influence on the complication rate. CONCLUSIONS Stabilization of DRF by palmar angular stable locking plate is a safe form of treatment. In the majority of the cases a good clinical and radiological outcome with no complications was documented. Gender and type of immobilization had no impact on the complication rate and an age over 65 years is not associated with an increased risk for complications or restricted ROM.
Collapse
|
12
|
Cai A, Pingel I, Lorz D, Beier JP, Horch RE, Arkudas A. Force distribution of a cylindrical grip differs between dominant and nondominant hand in healthy subjects. Arch Orthop Trauma Surg 2018; 138:1323-1331. [PMID: 29992376 DOI: 10.1007/s00402-018-2997-7] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/22/2018] [Indexed: 01/25/2023]
Abstract
INTRODUCTION Grip strength and load distribution of the hand are important parameters for evaluating hand function. The purpose of this study was to analyze and compare grip force and load distribution of dominant and nondominant hands in right-handed healthy subjects. METHODS Gripping measurements were performed on 40 healthy right-handed subjects using a cylindrical gripping device. Two different cylinders with circumferences of 150 mm (small cylinder) and 200 mm (large cylinder), respectively, were used for the measurements. Subjects were assigned to either the small or the large cylinder with respect to their hand size. Maximum and mean force applied during three intervals of gripping as well as the percent contribution of each digit, thenar, and hypothenar in relation to the total load applied were acquired. Values of dominant and nondominant hands were compared. RESULTS Percent contribution of mean grip strength differed for the thumb (p = 0.007), ring finger (p < 0.001), little finger (p = 0.047), and palm (p < 0.001). Comparing the dominant and nondominant side, the dominant hand showed a lower contribution of the thumb, ring finger, and little finger, but a higher contribution of the palm. When analyzing maximum grip, percent contribution of the small fingers was equal between dominant and nondominant side (p = 0.1). Differences between dominant and nondominant thumb, ring finger, and palm persisted (p = 0.007, p = 0.001, p = 0.005, respectively). No differences could be shown for the index finger, middle finger, thenar, and hypothenar when analyzing both mean and maximum force. DISCUSSION AND CONCLUSION Percent contribution of the thumb and the fingers to total grip strength differed between dominant and nondominant hands with a change in distribution when assessing maximum grip force. In right-handed subjects, thumb and ring finger have important roles during gripping.
Collapse
Affiliation(s)
- Aijia Cai
- Department of Plastic and Hand Surgery and Laboratory for Tissue Engineering and Regenerative Medicine, University Hospital Erlangen, Friedrich Alexander University Erlangen-Nuernberg FAU, Krankenhausstr. 12, 91054, Erlangen, Germany.
| | - I Pingel
- Department of Plastic and Hand Surgery and Laboratory for Tissue Engineering and Regenerative Medicine, University Hospital Erlangen, Friedrich Alexander University Erlangen-Nuernberg FAU, Krankenhausstr. 12, 91054, Erlangen, Germany
| | - D Lorz
- Department of Plastic and Hand Surgery and Laboratory for Tissue Engineering and Regenerative Medicine, University Hospital Erlangen, Friedrich Alexander University Erlangen-Nuernberg FAU, Krankenhausstr. 12, 91054, Erlangen, Germany
| | - J P Beier
- Department of Plastic and Hand Surgery and Laboratory for Tissue Engineering and Regenerative Medicine, University Hospital Erlangen, Friedrich Alexander University Erlangen-Nuernberg FAU, Krankenhausstr. 12, 91054, Erlangen, Germany
- Department of Plastic Surgery, Hand Surgery and Burn Center, Medical Faculty, RWTH Aachen University Hospital, Aachen, Germany
| | - R E Horch
- Department of Plastic and Hand Surgery and Laboratory for Tissue Engineering and Regenerative Medicine, University Hospital Erlangen, Friedrich Alexander University Erlangen-Nuernberg FAU, Krankenhausstr. 12, 91054, Erlangen, Germany
| | - A Arkudas
- Department of Plastic and Hand Surgery and Laboratory for Tissue Engineering and Regenerative Medicine, University Hospital Erlangen, Friedrich Alexander University Erlangen-Nuernberg FAU, Krankenhausstr. 12, 91054, Erlangen, Germany
| |
Collapse
|