1
|
New approaches to proven technology: force control posterior thoracolumbar fusion with an innovative pedicle screw system. INTERDISCIPLINARY NEUROSURGERY 2022. [DOI: 10.1016/j.inat.2022.101701] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
|
2
|
Novel Dual-Threaded Pedicle Screws Provide Fixation Stability That Is Comparable to That of Traditional Screws with Relative Bone Preservation: An In Vitro Biomechanical Study. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12126172] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Replacement with larger diameter screws is always used in pedicle screw loosening but carries a risk of pedicle wall violation. A pedicle screw with more preserved bone stock is the preferred primary fixation choice. The purpose of this study was to evaluate whether a newly designed proximal-conical dual-thread screw with less bone occupancy provides fixation strength comparable to that of a traditional screw. Six types of pedicle screws based on three different shapes (cylindrical, conical, and proximal-conical) and two thread profiles (single-thread and dual-thread) were grouped. Conical and proximal-conical screws differed mainly in the slope of the outer diameter from the hub to the tip. Conical screws had an outer diameter (6.5 mm) that differed from the hub and tapered by 30% to an outer diameter (4.5 mm) at the tip and proximal-conical screws had the same outer diameter from the hub and tapered by 30% (4.5 mm) at 20 mm from the hub and then maintained the outer diameter (45 mm) to the tip. A total of 36 L4 Sawbones® vertebrae were used in the study and six trials for each screw group. The results of the imaging, screw volume in bone, insertion torque, and pullout force were analyzed. For screws with the same shape, insertion torque and pullout force were significantly higher for those in the dual-thread groups than for those in the single-thread groups (p < 0.05). For screws with the same thread profile, there was no significant difference in either biomechanical test between the different screw shapes (p > 0.05). Our results demonstrated that these proximal-conical dual-thread screws, with the property of relative bone stock preservation, display a comparable biomechanical performance to traditional dual-thread screws and a better performance than single-thread screws. This screw design could serve as the primary pedicle screw choice to reduce revision difficulty.
Collapse
|
3
|
Cavalcanti Kußmaul A, Schwaabe F, Becker CA, Kleber C, Linhart C, Thorwächter C, Rubenbauer B, Böcker W, Greiner A. Does augmentation increase the pull-out force of symphyseal screws? A biomechanical cadaver study. Eur J Trauma Emerg Surg 2022; 48:4215-4221. [PMID: 35364692 PMCID: PMC9532288 DOI: 10.1007/s00068-022-01963-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2022] [Accepted: 03/17/2022] [Indexed: 11/28/2022]
Abstract
Purpose Open reduction and internal fixation using anterior plate osteosynthesis currently represents the gold standard for the treatment of symphyseal disruptions. Since postoperative screw loosening with consequent implant failure is frequently observed, this study aims to evaluate if and to what extent augmentation can increase the pull-out force of symphyseal screws to improve the constructs stability. Methods Twelve human cadaveric anterior pelvic rings were separated at the symphyseal joint for bilateral testing, consequently achieving comparable sites. First, one non-augmented screw was drilled into the superior pubic ramus, whereas the contralateral side was primarily augmented. The screws were then withdrawn with a constant speed of 10 mm/min and the fixation strengths determined by the force (N) displacement (mm) curve. Finally, the primary non-augmented site was secondary augmented, representing revision surgery after initial implant failure, and the corresponding fixation strength was measured again. Results Augmentation compared to non-augmented screws displayed significantly higher pull-out forces with an increase in pull-out force by 377% for primary and 353% for secondary augmentation (p < 0.01). There was no significant difference in the pull-out force comparing primary and secondary augmentation (p = 0.74). Conclusions Primary and secondary augmentation significantly increases the stability of symphyseal screws and, therefore, potentially decreases rates of implant failure. Supplementary Information The online version contains supplementary material available at 10.1007/s00068-022-01963-6.
Collapse
Affiliation(s)
- Adrian Cavalcanti Kußmaul
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany.
| | - Fanny Schwaabe
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - Christopher Alexander Becker
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - Christian Kleber
- Department of Orthopaedics, Trauma and Plastic Surgery, University Hospital Leipzig, Liebigstraße 20, 04103, Leipzig, Germany
| | - Christoph Linhart
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - Christoph Thorwächter
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - Bianka Rubenbauer
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - Wolfgang Böcker
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - Axel Greiner
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| |
Collapse
|
4
|
How relevant is lumbar bone mineral density for the stability of symphyseal implants? A biomechanical cadaver study. Eur J Trauma Emerg Surg 2021; 48:3101-3108. [PMID: 34881391 PMCID: PMC9360150 DOI: 10.1007/s00068-021-01850-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2021] [Accepted: 11/26/2021] [Indexed: 11/27/2022]
Abstract
PURPOSE Osteoporotic bone tissue appears to be an important risk factor for implant loosening, compromising the stability of surgical implants. However, it is unclear whether lumbar measured bone mineral density (BMD) is of any predictive value for stability of surgical implants at the pubic symphysis. This study examines the fixation strength of cortical screws in human cadaver specimens with different BMDs. METHODS The lumbar BMD of ten human specimens was measured using quantitative computed tomography (qCT). A cut-off BMD was set at 120 mg Ca-Ha/mL, dividing the specimens into two groups. One cortical screw was drilled into each superior pubic ramus. The screw was withdrawn in an axial direction with a steady speed and considered failed when a force decrease was detected. Required force (N) and pull-out distance (mm) were constantly tracked. RESULTS The median peak force of group 1 was 231.88 N and 228.08 N in group 2. While BMD values differed significantly (p < 0.01), a comparison of peak forces between both groups showed no significant difference (p = 0.481). CONCLUSION Higher lumbar BMD did not result in significantly higher pull-out forces at the symphysis. The high proportion of cortical bone near the symphyseal joint allows an increased contact of pubic screws and could explain sufficient fixation. This condition is not reflected by a compromised lumbar BMD in a qCT scan. Therefore, site-specific BMD measurement could improve individual fracture management.
Collapse
|