1
|
Burton A, Hardcastle N. In Regard to Owen et al. Int J Radiat Oncol Biol Phys 2024; 118:866-867. [PMID: 38340772 DOI: 10.1016/j.ijrobp.2023.11.022] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2023] [Accepted: 11/13/2023] [Indexed: 02/12/2024]
Affiliation(s)
- Alex Burton
- Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, Victoria, Australia; Sir Peter MacCallum Department of Oncology, University of Melbourne, Melbourne, Victoria, Australia; Australian Radiation Protection and Nuclear Safety Agency (ARPANSA), Yallambie, Victoria, Australia; School of Science, RMIT University, Melbourne, Victoria, Australia
| | - Nicholas Hardcastle
- Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, Victoria, Australia; Sir Peter MacCallum Department of Oncology, University of Melbourne, Melbourne, Victoria, Australia; Centre for Medical Radiation Physics, University of Wollongong, Wollongong, New South Wales, Australia
| |
Collapse
|
2
|
Darréon J, Debnath SBC, Benkreira M, Fau P, Mailleux H, Ferré M, Benkemouche A, Tallet A, Annede P, Petit C, Salem N. A novel lung SBRT treatment planning: Inverse VMAT plan with leaf motion limitation to ensure the irradiation reproducibility of a moving target. Med Dosim 2023; 49:159-164. [PMID: 38061915 DOI: 10.1016/j.meddos.2023.11.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2023] [Revised: 10/20/2023] [Accepted: 11/01/2023] [Indexed: 05/08/2024]
Abstract
This study exposed the implementation of a novel technique (VMATLSL) for the planning of moving targets in lung stereotactic body radiation therapy (SBRT). This new technique has been compared to static conformal radiotherapy (3D-CRT), volumetric-modulated arc therapy (VMAT), and dynamic conformal arc (DCA). The rationale of this study was to lower geometric complexity (54.9% lower than full VMAT) and hence ensure the reproducibility of the treatment delivery by reducing the risk for interplay errors induced by respiratory motion. Dosimetry metrics were studied with a cohort of 30 patients. Our results showed that leaf speed limitation provided conformal number (CN) close to the VMAT (median CN of VMATLSL is 0.78 vs 0.82 for full VMAT) and was a significant improvement on 3D-CRT and DCA with segment-weight optimized (respectively 0.55 and 0.57). This novel technique is an alternative to VMAT or DCA for lung SBRT treatments, combining independence from the patient's breathing pattern, from the size and amplitude of the lesion, free from interplay effect, and with dosimetry metrics close to the best that could be achieved with full VMAT.
Collapse
Affiliation(s)
- Julien Darréon
- Département de Physique Médicale, Institut Paoli-Calmettes, Marseille, 13009, France.
| | | | - Mohamed Benkreira
- Département de Physique Médicale, Institut Paoli-Calmettes, Marseille, 13009, France
| | - Pierre Fau
- Département de Physique Médicale, Institut Paoli-Calmettes, Marseille, 13009, France
| | - Hugues Mailleux
- Département de Physique Médicale, Institut Paoli-Calmettes, Marseille, 13009, France
| | - Marjorie Ferré
- Département de Physique Médicale, Institut Paoli-Calmettes, Marseille, 13009, France
| | - Ahcene Benkemouche
- Département de Physique Médicale, Institut Paoli-Calmettes, Marseille, 13009, France
| | - Agnès Tallet
- Institut Paoli-Calmettes, Service de Radiothérapie, Marseille, 13009, France
| | - Pierre Annede
- Centre de radiothérapie Saint Louis, Croix Rouge Française, Toulon, 83100, France
| | - Claire Petit
- Institut Paoli-Calmettes, Service de Radiothérapie, Marseille, 13009, France
| | - Naji Salem
- Institut Paoli-Calmettes, Service de Radiothérapie, Marseille, 13009, France
| |
Collapse
|
3
|
Varasteh M, Ali A, Esteve S, Jeevanandam P, Göpfert F, Irvine DM, Hounsell AR, McGarry CK. Patient specific evaluation of breathing motion induced interplay effects. Phys Med 2023; 105:102501. [PMID: 36529007 DOI: 10.1016/j.ejmp.2022.11.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/13/2022] [Revised: 09/18/2022] [Accepted: 11/23/2022] [Indexed: 12/23/2022] Open
Abstract
PURPOSE In lung SABR, interplay between target motion and dynamically changing beam parameters can affect the target coverage. To identify the potential need for motion-management techniques, a comprehensive methodology for pre-treatment estimation of interplay effects has been implemented. METHODS In conjunction with an alpha-version of VeriSoft and OCTAVIUS 4D (PTW-Freiburg, Germany), a method is presented to calculate a virtual, motion-simulated 3D dose distribution based on measurement data acquired in a stationary phantom and a subsequent correction with time-dependent target-motion patterns. In-house software has been developed to create user-defined motion patterns based on either simplistic or real patient-breathing patterns including the definition of the exact beam starting phase. The approach was validated by programmed couch and phantom motion during beam delivery. Five different breathing traces with extremely altered beam-on phases (0 % and 50 % respiratory phase) and a superior-inferior motion altitude of 25 mm were used to probe the influence of interplay effects for 14 lung SABR plans. Gamma analysis (2 %/2mm) was used for quantification. RESULTS Validation measurements resulted in >98 % pass rates. Regarding the interplay effect evaluation, gamma pass rates of <92 % were observed for sinusoidal breathing patterns with <25 number of breaths per delivery time (NBs) and realistic patterns with <18 NBs. CONCLUSION The potential influence of interplay effects on the target coverage is highly dependent on the patient's breathing behaviour. The presented moving-platform-free approach can be used for verification of ITV-based treatment plans to identify whether the clinical goals are achievable without explicit use of a respiratory management technique.
Collapse
Affiliation(s)
- Mohammad Varasteh
- Centre for Cancer Research and Cell Biology, Queen's University, Belfast, UK
| | - Asmaa Ali
- Centre for Cancer Research and Cell Biology, Queen's University, Belfast, UK
| | - Sergio Esteve
- Northern Ireland Cancer Centre, Belfast City Hospital, Belfast, UK
| | | | | | - Denise M Irvine
- Centre for Cancer Research and Cell Biology, Queen's University, Belfast, UK; Northern Ireland Cancer Centre, Belfast City Hospital, Belfast, UK
| | - Alan R Hounsell
- Centre for Cancer Research and Cell Biology, Queen's University, Belfast, UK; Northern Ireland Cancer Centre, Belfast City Hospital, Belfast, UK
| | - Conor K McGarry
- Centre for Cancer Research and Cell Biology, Queen's University, Belfast, UK; Northern Ireland Cancer Centre, Belfast City Hospital, Belfast, UK
| |
Collapse
|
4
|
Burton A, Beveridge S, Hardcastle N, Lye J, Sanagou M, Franich R. Adoption of respiratory motion management in radiation therapy. Phys Imaging Radiat Oncol 2022; 24:21-29. [PMID: 36148153 PMCID: PMC9485913 DOI: 10.1016/j.phro.2022.09.003] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2022] [Revised: 09/01/2022] [Accepted: 09/07/2022] [Indexed: 11/25/2022] Open
Abstract
Background and Purpose A survey on the patterns of practice of respiratory motion management (MM) was distributed to 111 radiation therapy facilities to inform the development of an end-to-end dosimetry audit including respiratory motion. Materials and methods The survey (distributed via REDCap) asked facilities to provide information specific to the combinations of MM techniques (breath-hold gating – BHG, internal target volume – ITV, free-breathing gating – FBG, mid-ventilation – MidV, tumour tracking – TT), sites treated (thorax, upper abdomen, lower abdomen), and fractionation regimes (conventional, stereotactic ablative body radiation therapy – SABR) used in their clinic. Results The survey was completed by 78% of facilities, with 98% of respondents indicating that they used at least one form of MM. The ITV approach was common to all MM-users, used for thoracic treatments by 89% of respondents, and upper and lower abdominal treatments by 38%. BHG was the next most prevalent (41% of MM users), with applications in upper abdominal and thoracic treatment sites (28% vs 25% respectively), but minimal use in the lower abdomen (9%). FBG and TT were utilised sparingly (17%, 7% respectively), and MidV was not selected at all. Conclusions Two distinct treatment workflows (including use of motion limitation, imaging used for motion assessment, dose calculation, and image guidance procedures) were identified for the ITV and BHG MM techniques, to form the basis of the initial audit. Thoracic SABR with the ITV approach was common to nearly all respondents, while upper abdominal SABR using BHG stood out as more technically challenging. Other MM techniques were sparsely used, but may be considered for future audit development.
Collapse
|
5
|
Gaudreault M, Yeo A, Kron T, Hanna GG, Siva S, Hardcastle N. Treatment Time Optimization in Single Fraction Stereotactic Ablative Radiation Therapy: A 10-Year Institutional Experience. Adv Radiat Oncol 2022; 7:100829. [PMID: 36148377 PMCID: PMC9486429 DOI: 10.1016/j.adro.2021.100829] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2021] [Accepted: 09/30/2021] [Indexed: 11/25/2022] Open
Abstract
Purpose Stereotactic ablative radiation therapy (SABR) delivered in a single fraction (SF) can be considered to have higher uncertainty given that the error probability is concentrated in a single session. This study aims to report the variation in technology and technique used and its effect on intrafraction motion based on a 10 years of experience in SF SABR. Methods and Materials Records of patients receiving SF SABR delivered at our instruction between 2010 and 2019 were included. Treatment parameters were extracted from the patient management database by using an in-house script. Treatment time was defined as the time difference between the first image acquisition to the last beam off of a single session. The intrafraction variation was measured from the 3-dimensional couch displacement measured after the first cone beam computed tomography (CBCT) acquired during a treatment. Results The number of SF SABR increased continuously from 2010 to 2019 and were mainly lung treatments. Treatment time was minimized by using volumetric modulated arc therapy, flattening filter-free dose rate, and coplanar field (24 ± 9 min). Treatment time increased as the number of CBCTs per session increased. The most common scenario involved both 2 and 3 CBCTs per session. On the average, a CBCT acquisition added 6 minutes to the treatment time. All treatments considered, the average intrafraction variation was 1.7 ± 1.6 mm. Conclusions SF SABR usage increased with time in our institution. The intrafraction motion was acceptable and therefore a single fraction is an efficacious treatment option when considering SABR.
Collapse
|
6
|
Sarudis S, Karlsson A, Nyman J, Bäck A. Dosimetric effects of respiratory motion during stereotactic body radiation therapy of lung tumors. Acta Oncol 2022; 61:1004-1011. [PMID: 35905048 DOI: 10.1080/0284186x.2022.2092420] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022]
Abstract
BACKGROUND Respiratory-induced lung tumor motion may affect the delivered dose in stereotactic body radiation therapy (SBRT). Previous studies are often based on phantom studies for one specific treatment technique. In this study, the dosimetric effect of tumor motion was quantified in real patient geometries for different modulated treatments and tumor motion amplitudes for lung-SBRT. MATERIAL AND METHODS A simulation method using deformable image registrations and 4-dimensional computed tomographies (4DCT) was developed to assess the dosimetric effects of tumor motion. The method was evaluated with ionization chamber and Gafchromic film measurements in a thorax phantom and used to simulate the effect for 15 patients with lung tumors moving 7.3-27.4 mm. Four treatment plans with different complexities were created for each patient and the motion-induced dosimetric effect to the gross tumor volume (GTV) was simulated. The difference between the planned dose to the static tumor and the simulated delivered dose to the moving tumor was quantified for the near minimum (D98%), near maximum (D2%) and mean dose (Dmean) to the GTV as well as the largest observed local difference within the GTV (Maxdiff). RESULTS No correlation was found between the dose differences and the tumor motion amplitude or plan complexity. However, the largest deviations were observed for tumors moving >15.0 mm. The simulated delivered dose was within 2.5% from the planned dose for D98% (tumors moving <15 mm) and within 3.3% (tumors moving >15 mm). The corresponding values were 1.7% vs. 6.4% (D2%); 1.7% vs. 2.4% (Dmean) and 8.9% vs. 35.2% (Maxdiff). Using less complex treatment techniques minimized Maxdiff for tumors moving >15.0 mm. CONCLUSION The dosimetric effects of respiratory-induced motion during lung SBRT are patient and plan specific. The magnitude of the dosimetric effect cannot be assessed solely based upon tumor motion amplitude or plan complexity.
Collapse
Affiliation(s)
- Sebastian Sarudis
- Department of Medical Radiation Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.,Department of Medical Physics, County Hospital Ryhov, Jönköping, Sweden
| | - Anna Karlsson
- Department of Medical Radiation Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.,Department of Therapeutic Radiation Physics, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Jan Nyman
- Department of Oncology, Sahlgrenska University Hospital, Gothenburg, Sweden.,Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Anna Bäck
- Department of Medical Radiation Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.,Department of Therapeutic Radiation Physics, Sahlgrenska University Hospital, Gothenburg, Sweden
| |
Collapse
|
7
|
Kang TM, Hardcastle N, Singh AK, Slotman BJ, Videtic GMM, Stephans KL, Couñago F, Louie AV, Guckenberger M, Harden SV, Plumridge NM, Siva S. Practical considerations of single-fraction stereotactic ablative radiotherapy to the lung. Lung Cancer 2022; 170:185-193. [PMID: 35843149 DOI: 10.1016/j.lungcan.2022.06.014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2022] [Revised: 06/21/2022] [Accepted: 06/24/2022] [Indexed: 10/17/2022]
Abstract
Stereotactic ablative radiotherapy (SABR) is a well-established treatment for patients with medically inoperable early-stage non-small cell lung cancer (NSCLC) and pulmonary oligometastases. The use of single-fraction SABR in this setting is supported by excellent local control and safety profiles which appear equivalent to multi-fraction SABR based on the available data. The resource efficiency and reduction in hospital outpatient visits associated with single-fraction SABR have been particularly advantageous during the COVID-19 pandemic. Despite the increased interest, single-fraction SABR in subgroups of patients remains controversial, including those with centrally located tumours, synchronous targets, proximity to dose-limiting organs at risk, and concomitant severe respiratory illness. This review provides an overview of the published randomised evidence evaluating single-fraction SABR in primary lung cancer and pulmonary oligometastases, the common clinical challenges faced, immunogenic effect of SABR, as well as technical and cost-utility considerations.
Collapse
Affiliation(s)
- Therese Mj Kang
- Department of Radiation Oncology, Peter MacCallum Cancer Centre, Melbourne, VIC, Australia
| | - Nicholas Hardcastle
- Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, VIC, Australia; Sir Peter MacCallum, Department of Oncology, University of Melbourne, Australia; Centre for Medical Radiation Physics, University of Wollongong, New South Wales, Australia
| | - Anurag K Singh
- Department of Radiation Medicine, Roswell Park Comprehensive Cancer Center, Buffalo, New York, USA
| | - Ben J Slotman
- Department of Radiation Oncology, Amsterdam University Medical Center, Amsterdam, the Netherlands
| | - Gregory M M Videtic
- Department of Radiation Oncology, Cleveland Clinic Taussig Cancer Institute, Cleveland, Ohio, USA
| | - Kevin L Stephans
- Department of Radiation Oncology, Cleveland Clinic Taussig Cancer Institute, Cleveland, Ohio, USA
| | - Felipe Couñago
- Department of Radiation Oncology, Hospital Universitario Quirónsalud, Madrid, Spain
| | - Alexander V Louie
- Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada
| | - Matthias Guckenberger
- Department of Radiation Oncology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Susan V Harden
- Department of Radiation Oncology, Peter MacCallum Cancer Centre, Melbourne, VIC, Australia
| | - Nikki M Plumridge
- Department of Radiation Oncology, Peter MacCallum Cancer Centre, Melbourne, VIC, Australia
| | - Shankar Siva
- Department of Radiation Oncology, Peter MacCallum Cancer Centre, Melbourne, VIC, Australia; Sir Peter MacCallum, Department of Oncology, University of Melbourne, Australia.
| |
Collapse
|
8
|
Gaudreault M, Offer K, Kron T, Siva S, Hardcastle N. On the reduction of aperture complexity in kidney SABR. J Appl Clin Med Phys 2021; 22:71-81. [PMID: 33756036 PMCID: PMC8035567 DOI: 10.1002/acm2.13215] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2020] [Revised: 02/07/2021] [Accepted: 02/17/2021] [Indexed: 01/28/2023] Open
Abstract
Background Stereotactic ablative body radiotherapy (SABR) of primary kidney cancers is confounded by motion. There is a risk of interplay effect if the dose is delivered using volumetric modulated arc therapy (VMAT) and flattening filter‐free (FFF) dose rates due to target and linac motion. This study aims to provide an efficient way to generate plans with minimal aperture complexity. Methods In this retrospective study, 62 patients who received kidney SABR were reviewed. For each patient, two plans were created using internal target volume based motion management, on the average intensity projection of a four‐dimensional CT. In the first plan, optimization was performed using a knowledge‐based planning model based on delivered clinical plans in our institution. In the second plan, the optimization was repeated, with a maximum monitor unit (MU) objective applied in the optimization. Dose‐volume, conformity, and complexity metric (with the field edge metric and the modulation complexity score) were compared between the two plans. Results are shown in terms of median (first quartile — third quartile). Results Similar dosimetry was obtained with and without the utilization of an objective on the MU. However, complexity was reduced by using the objective on the MUs (modulation complexity score = 0.55 (0.50–0.61) / 0.33 (0.29–0.36), P‐value < 10−10, with/without the MU objective). Reduction of complexity was driven by a larger aperture area (area aperture variability = 0.68 (0.64–0.73) / 0.42 (0.37–0.45), P‐value < 10−10, with/without the MU objective). Using the objective on the MUs resulted in a more spherical dose distribution (sphericity 50% isodose = 0.73 (0.69–0.75) / 0.64 (0.60–0.68), P‐value < 10−8, with/without the MU objective) reducing dose to organs at risk given respiratory motion. Conclusions Aperture complexity is reduced in kidney SABR by using an objective on the MU delivery with VMAT and FFF dose rate.
Collapse
Affiliation(s)
- Mathieu Gaudreault
- Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, Vic., Australia.,Sir Peter MacCallum Department of Oncology, The University of Melbourne, Melbourne, Vic., Australia
| | - Keith Offer
- Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, Vic., Australia
| | - Tomas Kron
- Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, Vic., Australia.,Sir Peter MacCallum Department of Oncology, The University of Melbourne, Melbourne, Vic., Australia
| | - Shankar Siva
- Sir Peter MacCallum Department of Oncology, The University of Melbourne, Melbourne, Vic., Australia.,Department of Radiation Oncology, Peter MacCallum Cancer Centre, Melbourne, Vic., Australia
| | - Nicholas Hardcastle
- Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, Vic., Australia.,Sir Peter MacCallum Department of Oncology, The University of Melbourne, Melbourne, Vic., Australia.,Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW, Australia
| |
Collapse
|
9
|
Stera S, Miebach G, Buergy D, Dreher C, Lohr F, Wurster S, Rödel C, Marcella S, Krug D, Frank A G, Ehmann M, Fleckenstein J, Blanck O, Boda-Heggemann J. Liver SBRT with active motion-compensation results in excellent local control for liver oligometastases: An outcome analysis of a pooled multi-platform patient cohort. Radiother Oncol 2021; 158:230-236. [PMID: 33667585 DOI: 10.1016/j.radonc.2021.02.036] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2020] [Revised: 02/10/2021] [Accepted: 02/24/2021] [Indexed: 10/22/2022]
Abstract
BACKGROUND Local treatment of metastases in combination with systemic therapy can prolong survival of oligo-metastasized patients. To fully exploit this potential, safe and effective treatments are needed to ensure long-term metastases control. Stereotactic body radiotherapy (SBRT) is one means, however, for moving liver tumors correct delivery of high doses is challenging. After validating equal in-vivo treatment accuracy, we analyzed a pooled multi-platform liver-SBRT-database for clinical outcome. METHODS Local control (LC), progression-free interval (PFI), overall survival (OS), predictive factors and toxicity was evaluated in 135 patients with 227 metastases treated by gantry-based SBRT (deep-inspiratory breath-hold-gating; n = 71) and robotic-based SBRT (fiducial-tracking, n = 156) with mean gross tumor volume biological effective dose (GTV-BEDα/β=10Gy) of 146.6 Gy10. RESULTS One-, and five-year LC was 90% and 68.7%, respectively. On multivariate analysis, LC was significantly predicted by colorectal histology (p = 0.006). Median OS was 20 months with one- and two-year OS of 67% and 37%. On multivariate analysis, ECOG-status (p = 0.003), simultaneous chemotherapy (p = 0.003), time from metastasis detection to SBRT-treatment (≥2months; p = 0.021) and LC of the treated metastases (≥12 months, p < 0.009) were significant predictors for OS. One- and two-year PFI were 30.5% and 14%. Acute toxicity was mild and rare (14.4% grade I, 2.3% grade II, 0.6% grade III). Chronic °III/IV toxicities occurred in 1.1%. CONCLUSIONS Patient selection, time to treatment and sufficient doses are essential to achieve optimal outcome for SBRT with active motion compensation. Local control appears favorable compared to historical control. Long-term LC of the treated lesions was associated with longer overall survival.
Collapse
Affiliation(s)
- Susanne Stera
- University Hospital Frankfurt, Department of Radiation Oncology, Frankfurt am Main, Germany.
| | - Georgia Miebach
- University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Department of Radiation Oncology, Germany
| | - Daniel Buergy
- University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Department of Radiation Oncology, Germany
| | - Constantin Dreher
- University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Department of Radiation Oncology, Germany
| | - Frank Lohr
- UO di Radioterapia, Dipartimento di Oncologia, Azienda Ospedaliero-Universitaria di Modena, Italy
| | - Stefan Wurster
- Saphir Radiosurgery Center, Güstrow, Germany; University Medicine Greifswald, Department of Radiation Oncology, Germany
| | - Claus Rödel
- University Hospital Frankfurt, Department of Radiation Oncology, Frankfurt am Main, Germany
| | - Szücs Marcella
- University Medicine Rostock, Department of Radiation Oncology, Germany
| | - David Krug
- Saphir Radiosurgery Center, Güstrow, Germany; University Medical Center Schleswig-Holstein, Department of Radiation Oncology, Kiel, Germany
| | - Giordano Frank A
- Department of Radiation Oncology, University Hospital Bonn, University of Bonn, Germany
| | - Michael Ehmann
- University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Department of Radiation Oncology, Germany
| | - Jens Fleckenstein
- University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Department of Radiation Oncology, Germany
| | - Oliver Blanck
- Saphir Radiosurgery Center, Güstrow, Germany; University Medical Center Schleswig-Holstein, Department of Radiation Oncology, Kiel, Germany
| | - Judit Boda-Heggemann
- University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Department of Radiation Oncology, Germany
| |
Collapse
|
10
|
4D CT image artifacts affect local control in SBRT of lung and liver metastases. Radiother Oncol 2020; 148:229-234. [DOI: 10.1016/j.radonc.2020.04.006] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2019] [Revised: 04/03/2020] [Accepted: 04/05/2020] [Indexed: 12/25/2022]
|
11
|
Adamczyk M, Kruszyna-Mochalska M, Rucińska A, Piotrowski T. Software simulation of tumour motion dose effects during flattened and unflattened ITV-based VMAT lung SBRT. Rep Pract Oncol Radiother 2020; 25:684-691. [PMID: 32581656 DOI: 10.1016/j.rpor.2020.06.003] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2020] [Revised: 05/04/2020] [Accepted: 06/02/2020] [Indexed: 12/21/2022] Open
Abstract
Purpose Restricted studies comparing different dose rate parameters are available while ITV-based VMAT lung SBRT planning leads to perform the analysis of the most suitable parameters of the external beams used. The special emphasis was placed on the impact of dose rate on dose distribution variations in target volumes due to interplay effects. Methods Four VMAT plans were calculated for 15 lung tumours using 6 MV photon beam quality (flattening filter FF vs. flattening filter free FFF beams) and maximum dose rate of 600 MU/min, 1000 MU/min and 1400 MU/min. Three kinds of motion simulations were performed finally giving 180 plans with perturbed dose distributions. Results 6FFF-1400 MUs/min plans were characterized by the shortest beam on time (1.8 ± 0.2 min). Analysing the performed motion simulation results, the mean dose (Dmean) is not a sensitive parameter to related interplay effects. Looking for local maximum and local minimum doses, some discrepancies were found, but their significance was presented for individual patients, not for the whole cohort. The same was observed for other verified dose metrics. Conclusions Generally, the evaluation of VMAT robustness between FF and FFF concepts against interplay effect showed a negligible effect of simulated motion influence on tumour coverage among different photon beam quality parameters. Due to the lack of FFF beams, smaller radiotherapy centres are able to perform ITV-based VMAT lung SBRT treatment in a safe way. Radiotherapy department having FFF beams could perform safe, fast and efficient ITV-based VMAT lung SBRT without a concern about significance of interplay effects.
Collapse
Affiliation(s)
- Marta Adamczyk
- Department of Medical Physics, Greater Poland Cancer Centre, Poznań, Poland
| | - Marta Kruszyna-Mochalska
- Department of Medical Physics, Greater Poland Cancer Centre, Poznań, Poland
- Department of Electroradiology, Poznań University of Medical Sciences, Poznań, Poland
| | - Anna Rucińska
- 1st Radiotherapy Ward, Greater Poland Cancer Centre, Poznań, Poland
| | - Tomasz Piotrowski
- Department of Medical Physics, Greater Poland Cancer Centre, Poznań, Poland
- Department of Electroradiology, Poznań University of Medical Sciences, Poznań, Poland
| |
Collapse
|
12
|
Burton A, Offer K, Hardcastle N. A robust VMAT delivery solution for single-fraction lung SABR utilizing FFF beams minimizing dosimetric compromise. J Appl Clin Med Phys 2020; 21:299-304. [PMID: 32469150 PMCID: PMC7484828 DOI: 10.1002/acm2.12919] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2020] [Revised: 04/29/2020] [Accepted: 04/30/2020] [Indexed: 12/25/2022] Open
Abstract
Peripheral lung lesions treated with a single fraction of stereotactic ablative body radiotherapy (SABR) utilizing volumetric modulated arc therapy (VMAT) delivery and flattening filter‐free (FFF) beams represent a potentially high‐risk scenario for clinically significant dose blurring effects due to interplay between the respiratory motion of the lesion and dynamic multi‐leaf collimators (MLCs). The aim of this study was to determine an efficient means of developing low‐modulation VMAT plans in the Eclipse treatment planning system (v15.5, Varian Medical Systems, Palo Alto, USA) in order to minimize this risk, while maintaining dosimetric quality. The study involved 19 patients where an internal target volume (ITV) was contoured to encompass the entire range of tumor motion, and a planning target volume (PTV) created using a 5‐mm isotropic expansion of this contour. Each patient had seven plan variations created, with each rescaled to achieve the clinical planning goal for PTV coverage. All plan variations used the same field arrangement, and consisted of one dynamic conformal arc therapy (DCAT) plan, and six VMAT plans with varying degrees of modulation restriction, achieved through utilizing different combinations of the aperture shape controller (ASC) in the calculation parameters, and monitor unit (MU) objective during optimization. The dosimetric quality was assessed based on RTOG conformity indices (CI100/CI50), as well as adherence to dose–volume metrics used clinically at our institution. Plan complexity was assessed based on the modulation factor (MU/cGy) and the field edge metric. While VMAT plans with the least modulation restriction achieved the best dosimetry, it was found that there was no clinically significant trade‐off in terms of dose to organs at risk and conformity by reducing complexity. Furthermore, it was found that utilizing the ASC and MU objective could reduce plan complexity to near‐DCAT levels with improved dosimetry, which may be sufficiently robust to overcome the interplay effect.
Collapse
Affiliation(s)
- Alex Burton
- Peter MacCallum Cancer Centre, Melbourne, VIC, Australia
| | - Keith Offer
- Peter MacCallum Cancer Centre, Melbourne, VIC, Australia
| | - Nicholas Hardcastle
- Peter MacCallum Cancer Centre, Melbourne, VIC, Australia.,Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW, Australia
| |
Collapse
|
13
|
Schmitt D, Blanck O, Gauer T, Fix MK, Brunner TB, Fleckenstein J, Loutfi-Krauss B, Manser P, Werner R, Wilhelm ML, Baus WW, Moustakis C. Technological quality requirements for stereotactic radiotherapy : Expert review group consensus from the DGMP Working Group for Physics and Technology in Stereotactic Radiotherapy. Strahlenther Onkol 2020; 196:421-443. [PMID: 32211939 PMCID: PMC7182540 DOI: 10.1007/s00066-020-01583-2] [Citation(s) in RCA: 66] [Impact Index Per Article: 16.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2020] [Accepted: 01/13/2020] [Indexed: 12/25/2022]
Abstract
This review details and discusses the technological quality requirements to ensure the desired quality for stereotactic radiotherapy using photon external beam radiotherapy as defined by the DEGRO Working Group Radiosurgery and Stereotactic Radiotherapy and the DGMP Working Group for Physics and Technology in Stereotactic Radiotherapy. The covered aspects of this review are 1) imaging for target volume definition, 2) patient positioning and target volume localization, 3) motion management, 4) collimation of the irradiation and beam directions, 5) dose calculation, 6) treatment unit accuracy, and 7) dedicated quality assurance measures. For each part, an expert review for current state-of-the-art techniques and their particular technological quality requirement to reach the necessary accuracy for stereotactic radiotherapy divided into intracranial stereotactic radiosurgery in one single fraction (SRS), intracranial fractionated stereotactic radiotherapy (FSRT), and extracranial stereotactic body radiotherapy (SBRT) is presented. All recommendations and suggestions for all mentioned aspects of stereotactic radiotherapy are formulated and related uncertainties and potential sources of error discussed. Additionally, further research and development needs in terms of insufficient data and unsolved problems for stereotactic radiotherapy are identified, which will serve as a basis for the future assignments of the DGMP Working Group for Physics and Technology in Stereotactic Radiotherapy. The review was group peer-reviewed, and consensus was obtained through multiple working group meetings.
Collapse
Affiliation(s)
- Daniela Schmitt
- Klinik für Radioonkologie und Strahlentherapie, National Center for Radiation Research in Oncology (NCRO), Heidelberger Institut für Radioonkologie (HIRO), Universitätsklinikum Heidelberg, Heidelberg, Germany.
| | - Oliver Blanck
- Klinik für Strahlentherapie, Universitätsklinikum Schleswig-Holstein, Kiel, Germany
| | - Tobias Gauer
- Klinik für Strahlentherapie und Radioonkologie, Universitätsklinikum Hamburg-Eppendorf, Hamburg, Germany
| | - Michael K Fix
- Abteilung für Medizinische Strahlenphysik und Universitätsklinik für Radio-Onkologie, Inselspital-Universitätsspital Bern, Universität Bern, Bern, Switzerland
| | - Thomas B Brunner
- Universitätsklinik für Strahlentherapie, Universitätsklinikum Magdeburg, Magdeburg, Germany
| | - Jens Fleckenstein
- Klinik für Strahlentherapie und Radioonkologie, Universitätsmedizin Mannheim, Universität Heidelberg, Mannheim, Germany
| | - Britta Loutfi-Krauss
- Klinik für Strahlentherapie und Onkologie, Universitätsklinikum Frankfurt, Frankfurt am Main, Germany
| | - Peter Manser
- Abteilung für Medizinische Strahlenphysik und Universitätsklinik für Radio-Onkologie, Inselspital-Universitätsspital Bern, Universität Bern, Bern, Switzerland
| | - Rene Werner
- Institut für Computational Neuroscience, Universitätsklinikum Hamburg-Eppendorf, Hamburg, Germany
| | - Maria-Lisa Wilhelm
- Klinik für Strahlentherapie, Universitätsmedizin Rostock, Rostock, Germany
| | - Wolfgang W Baus
- Klinik für Radioonkologie, CyberKnife- und Strahlentherapie, Universitätsklinikum Köln, Cologne, Germany
| | - Christos Moustakis
- Klinik für Strahlentherapie-Radioonkologie, Universitätsklinikum Münster, Münster, Germany
| |
Collapse
|
14
|
A novel approach to SBRT patient quality assurance using EPID-based real-time transit dosimetry. Strahlenther Onkol 2020; 196:182-192. [DOI: 10.1007/s00066-019-01549-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2019] [Accepted: 10/26/2019] [Indexed: 12/25/2022]
|
15
|
Freislederer P, von Münchow A, Kamp F, Heinz C, Gerum S, Corradini S, Söhn M, Reiner M, Roeder F, Floca R, Alber M, Belka C, Parodi K. Comparison of planned dose on different CT image sets to four-dimensional Monte Carlo dose recalculation using the patient's actual breathing trace for lung stereotactic body radiation therapy. Med Phys 2019; 46:3268-3277. [PMID: 31074510 DOI: 10.1002/mp.13579] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2018] [Revised: 04/17/2019] [Accepted: 04/18/2019] [Indexed: 12/25/2022] Open
Abstract
PURPOSE The need for four-dimensional (4D) treatment planning becomes indispensable when it comes to radiation therapy for moving tumors in the thoracic and abdominal regions. The primary purpose of this study is to combine the actual breathing trace during each individual treatment fraction with the Linac's log file information and Monte Carlo 4D dose calculations. We investigated this workflow on multiple computed tomography (CT) datasets in a clinical environment for stereotactic body radiation therapy (SBRT) treatment planning. METHODS We have developed a workflow, which allows us to recalculate absorbed dose to a 4DCT dataset using Monte Carlo calculation methods and accumulate all 4D doses in order to compare them to the planned dose using the Linac's log file, a 4DCT dataset, and the patient's actual breathing curve for each individual fraction. For five lung patients, three-dimensional-conformal radiation therapy (3D-CRT) and volumetric modulated arc treatment (VMAT) treatment plans were generated on four different CT image datasets: a native free-breathing 3DCT, an average intensity projection (AIP) and a maximum intensity projection (MIP) CT both obtained from a 4DCT, and a 3DCT with density overrides based on the 3DCT (DO). The Monte Carlo 4D dose has been calculated on each 4DCT phase using the Linac's log file and the patient's breathing trace as a surrogate for tumor motion and dose was accumulated to the gross tumor volume (GTV) at the 50% breathing phase (end of exhale) using deformable image registration. RESULTS Δ D 98 % and Δ D 2 % between 4D dose and planned dose differed largely for 3DCT-based planning and also for DO in three patients. Least dose differences between planned and recalculated dose have been found for AIP and MIP treatment planning which both tend to be superior to DO, but the results indicate a dependency on the breathing variability, tumor motion, and size. An interplay effect has not been observed in the small patient cohort. CONCLUSIONS We have developed a workflow which, to our best knowledge, is the first incorporation of the patient breathing trace over the course of all individual treatment fractions with the Linac's log file information and 4D Monte Carlo recalculations of the actual treated dose. Due to the small patient cohort, no clear recommendation on which CT can be used for SBRT treatment planning can be given, but the developed workflow, after adaption for clinical use, could be used to enhance a priori 4D Monte Carlo treatment planning in the future and help with the decision on which CT dataset treatment planning should be carried out.
Collapse
Affiliation(s)
- Philipp Freislederer
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany
| | - Asmus von Münchow
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany
| | - Florian Kamp
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany
| | - Christian Heinz
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany
| | - Sabine Gerum
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany
| | - Stefanie Corradini
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany
| | - Matthias Söhn
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany
| | - Michael Reiner
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany
| | - Falk Roeder
- Department of Radiotherapy and Radiation Oncology, Paracelsus Medical University, Landeskrankenhaus, Salzburg, Austria.,CCU Molecular Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Ralf Floca
- Heidelberg Institute of Radiation Oncology (HIRO), National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany.,Division of Medical Image Computing, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Markus Alber
- Heidelberg Institute of Radiation Oncology (HIRO), National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany.,Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany
| | - Claus Belka
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany.,German Cancer Consortium (DKTK), Munich, Germany.,Member of the German Center for Lung Research (DZL), Comprehensive Pneumology Center Munich (CPC-M), Munich, Germany
| | - Katia Parodi
- Department of Experimental Physics - Medical Physics, LMU Munich, Munich, Germany
| |
Collapse
|