1
|
Lai J, Luo Z, Jiang L, Hu H, Gao C, Zhang C, Chen L, Wu J, Wu Z. Skin marker combined with surface-guided auto-positioning for breast DIBH radiotherapy daily initial patient setup: An optimal schedule for both accuracy and efficiency. J Appl Clin Med Phys 2024; 25:e14319. [PMID: 38522035 PMCID: PMC11244673 DOI: 10.1002/acm2.14319] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2023] [Revised: 01/31/2024] [Accepted: 02/12/2024] [Indexed: 03/25/2024] Open
Abstract
BACKGROUND AND PURPOSE By employing three surface-guided radiotherapy (SGRT)-assisted positioning methods, we conducted a prospective study of patients undergoing SGRT-based deep inspiration breath-hold (DIBH) radiotherapy using a Sentine/Catalys system. The aim of this study was to optimize the initial positioning workflow of SGRT-DIBH radiotherapy for breast cancer. MATERIALS AND METHODS A total of 124 patients were divided into three groups to conduct a prospective comparative study of the setup accuracy and efficiency for the daily initial setup of SGRT-DIBH breast radiotherapy. Group A was subjected to skin marker plus SGRT verification, Group B underwent SGRT optical feedback plus auto-positioning, and Group C was subjected to skin marker plus SGRT auto-positioning. We evaluated setup accuracy and efficiency using cone-beam computed tomography (CBCT) verification data and the total setup time. RESULTS In groups A, B, and C, the mean and standard deviation of the translational setup-error vectors were small, with the highest values of the three directions observed in group A (2.4 ± 1.6, 2.9 ± 1.8, and 2.8 ± 2.1 mm). The rotational vectors in group B (1.8 ± 0.7°, 2.1 ± 0.8°, and 1.8 ± 0.7°) were significantly larger than those in groups A and C, and the Group C setup required the shortest amount of time, at 1.5 ± 0.3 min, while that of Group B took the longest time, at 2.6 ± 0.9 min. CONCLUSION SGRT one-key calibration was found to be more suitable when followed by skin marker/tattoo and in-room laser positioning, establishing it as an optimal daily initial set-up protocol for breast DIBH radiotherapy. This modality also proved to be suitable for free-breathing breast cancer radiotherapy, and its widespread clinical use is recommended.
Collapse
Affiliation(s)
- Jianjun Lai
- Instiute of Intelligent Control and RoboticsHangzhou Dianzi UniversityHangzhouChina
- Department of Radiation OncologyZhejiang HospitalHangzhouChina
| | - Zhizeng Luo
- Instiute of Intelligent Control and RoboticsHangzhou Dianzi UniversityHangzhouChina
| | - Lu Jiang
- Department of Radiation OncologyZhejiang HospitalHangzhouChina
| | - Haili Hu
- Department of Radiation OncologyZhejiang HospitalHangzhouChina
| | - Chang Gao
- Department of Radiation OncologyZhejiang HospitalHangzhouChina
| | - Chuanfeng Zhang
- Department of Radiation OncologyZhejiang HospitalHangzhouChina
| | - Liting Chen
- Department of Radiation OncologyZhejiang HospitalHangzhouChina
| | - Jing Wu
- Department of Radiation OncologyZhejiang HospitalHangzhouChina
| | - Zhibing Wu
- Department of Radiation OncologyZhejiang HospitalHangzhouChina
| |
Collapse
|
2
|
Buschmann M, Kauer-Dorner D, Konrad S, Georg D, Widder J, Knäusl B. Stereoscopic X-ray image and thermo-optical surface guidance for breast cancer radiotherapy in deep inspiration breath-hold. Strahlenther Onkol 2024; 200:306-313. [PMID: 37796341 DOI: 10.1007/s00066-023-02153-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2023] [Accepted: 08/30/2023] [Indexed: 10/06/2023]
Abstract
PURPOSE To investigate the feasibility of a thermo-optical surface imaging (SGRT) system combined with room-based stereoscopic X‑ray image guidance (IGRT) in a dedicated breast deep inspiration breath-hold (DIBH) irradiation workflow. In this context, benchmarking of portal imaging (EPID) and cone-beam CT (CBCT) against stereoscopic X‑rays was performed. METHODS SGRT + IGRT data of 30 left-sided DIBH breast patients (1 patient with bilateral cancer) treated in 351 fractions using thermo-optical surface imaging and X-ray IGRT were retrospectively analysed. Patients were prepositioned based on a free-breathing surface reference derived from a CT scan. Once the DIBH was reached using visual feedback, two stereoscopic X‑ray images were acquired and registered to the digitally reconstructed radiographs derived from the DIBH CT. Based on this registration, a couch correction was performed. Positioning and monitoring by surface and X-ray imaging were verified by protocol-based EPID or CBCT imaging at selected fractions and the calculation of residual geometric deviations. RESULTS The median X‑ray-derived couch correction vector was 4.9 (interquartile range [IQR] 3.3-7.1) mm long. Verification imaging was performed for 134 fractions (216 RT field verifications) with EPID and for 37 fractions with CBCT, respectively. The median 2D/3D deviation vector length over all verification images was 2.5 (IQR 1.6-3.9) mm/3.4 (IQR 2.2-4.8) mm for EPID/CBCT, both being well within the planning target volume (PTV) margins (7 mm). A moderate correlation (0.49-0.65) was observed between the surface signal and X-ray position in DIBH. CONCLUSION DIBH treatments using thermo-optical SGRT and X-ray IGRT were feasible for breast cancer patients. Stereoscopic X‑ray positioning was successfully verified by standard IGRT techniques.
Collapse
Affiliation(s)
- Martin Buschmann
- Department of Radiation Oncology, Comprehensive Cancer Center, Medical University of Vienna/AKH Wien, Währinger Gürtel 18-20, Vienna, 1090, Austria
| | - Daniela Kauer-Dorner
- Department of Radiation Oncology, Comprehensive Cancer Center, Medical University of Vienna/AKH Wien, Währinger Gürtel 18-20, Vienna, 1090, Austria
| | - Stefan Konrad
- Department of Radiation Oncology, Comprehensive Cancer Center, Medical University of Vienna/AKH Wien, Währinger Gürtel 18-20, Vienna, 1090, Austria
| | - Dietmar Georg
- Department of Radiation Oncology, Comprehensive Cancer Center, Medical University of Vienna/AKH Wien, Währinger Gürtel 18-20, Vienna, 1090, Austria
| | - Joachim Widder
- Department of Radiation Oncology, Comprehensive Cancer Center, Medical University of Vienna/AKH Wien, Währinger Gürtel 18-20, Vienna, 1090, Austria
| | - Barbara Knäusl
- Department of Radiation Oncology, Comprehensive Cancer Center, Medical University of Vienna/AKH Wien, Währinger Gürtel 18-20, Vienna, 1090, Austria.
| |
Collapse
|
3
|
Schöpe M, Sahlmann J, Jaschik S, Findeisen A, Klautke G. Comparison of patient setup accuracy for optical surface-guided and X-ray-guided imaging with respect to the impact on intracranial stereotactic radiotherapy. Strahlenther Onkol 2024; 200:60-70. [PMID: 37971534 DOI: 10.1007/s00066-023-02170-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2022] [Accepted: 10/11/2023] [Indexed: 11/19/2023]
Abstract
PURPOSE The objective of this work is to estimate the patient positioning accuracy of a surface-guided radiation therapy (SGRT) system using an optical surface scanner compared to an X‑ray-based imaging system (IGRT) with respect to their impact on intracranial stereotactic radiotherapy (SRT) and intracranial stereotactic radiosurgery (SRS). METHODS Patient positioning data, both acquired with SGRT and IGRT systems at the same linacs, serve as a basis for determination of positioning accuracy. A total of 35 patients with two different open face masks (578 datasets) were positioned using X‑ray stereoscopic imaging and the patient position inside the open face mask was recorded using SGRT. The measurement accuracy of the SGRT system (in a "standard" and an SRS mode with higher resolution) was evaluated using both IGRT and SGRT patient positioning datasets taking into account the measurement errors of the X‑ray system. Based on these clinically measured datasets, the positioning accuracy was estimated using Monte Carlo (MC) simulations. The relevant evaluation criterion, as standard of practice in cranial SRT, was the 95th percentile. RESULTS The interfractional measurement displacement vector of the SGRT system, σSGRT, in high resolution mode was estimated at 2.5 mm (68th percentile) and 5 mm (95th percentile). If the standard resolution was used, σSGRT increased by about 20%. The standard deviation of the axis-related σSGRT of the SGRT system ranged between 1.5 and 1.8 mm interfractionally and 0.5 and 1.0 mm intrafractionally. The magnitude of σSGRT is mainly due to the principle of patient surface scanning and not due to technical limitations or vendor-specific issues in software or hardware. Based on the resulting σSGRT, MC simulations served as a measure for the positioning accuracy for non-coplanar couch rotations. If an SGRT system is used as the only patient positioning device in non-coplanar fields, interfractional positioning errors of up to 6 mm and intrafractional errors of up to 5 mm cannot be ruled out. In contrast, MC simulations resulted in a positioning error of 1.6 mm (95th percentile) using the IGRT system. The cause of positioning errors in the SGRT system is mainly a change in the facial surface relative to a defined point in the brain. CONCLUSION In order to achieve the necessary geometric accuracy in cranial stereotactic radiotherapy, use of an X‑ray-based IGRT system, especially when treating with non-coplanar couch angles, is highly recommended.
Collapse
Affiliation(s)
- Michael Schöpe
- Department of Radiation Oncology, Klinikum Chemnitz gGmbH, Bürgerstraße 2, 09113, Chemnitz, Germany
| | - Jacob Sahlmann
- Department of Radiation Oncology, Klinikum Chemnitz gGmbH, Bürgerstraße 2, 09113, Chemnitz, Germany
| | - Stefan Jaschik
- Department of Radiation Oncology, Klinikum Chemnitz gGmbH, Bürgerstraße 2, 09113, Chemnitz, Germany.
| | - Anne Findeisen
- Department of Radiation Oncology, Klinikum Chemnitz gGmbH, Bürgerstraße 2, 09113, Chemnitz, Germany
| | - Gunther Klautke
- Department of Radiation Oncology, Klinikum Chemnitz gGmbH, Bürgerstraße 2, 09113, Chemnitz, Germany
| |
Collapse
|
4
|
Giantsoudi D, Lalonde A, Barra C, Vanbenthuysen L, Taghian AG, Gierga DP, Jimenez RB. Tattoo-Free Setup for Patients With Breast Cancer Receiving Regional Nodal Irradiation. Pract Radiat Oncol 2023; 13:e20-e27. [PMID: 35948179 DOI: 10.1016/j.prro.2022.08.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2022] [Revised: 08/01/2022] [Accepted: 08/01/2022] [Indexed: 01/10/2023]
Abstract
PURPOSE Patients undergoing regional nodal irradiation (RNI) with either 3-dimensional conformal radiation therapy (3DCRT) planning or volumetric modulated arc therapy (VMAT) receive permanent tattoos to assist with daily setup alignment and verification. With the advent of surface imaging, tattoos may not be necessary to ensure setup accuracy. We compared the accuracy of conventional tattoo-based setups to those without reference to tattoos. METHODS AND MATERIALS Forty-eight patients receiving RNI at our institution from July 2019 to December 2020 were identified. All patients received tattoos per standard of care. Twenty-four patients underwent setup using tattoos for initial positioning followed by surface and x-ray imaging. A subsequent 24 patients underwent positioning using surface imaging followed by x-ray imaging without reference to tattoos. Patient cohorts were balanced by treatment technique and use of deep inspiration breath hold. Treatment (including setup and delivery) time and x-ray-based shifts after surface imaging were recorded. RESULTS Among patients in the tattoo group receiving 3DCRT RNI, the average treatment time per fraction was 21.35 versus 19.75 minutes in the 3DCRT RNI no-tattoo cohort (P = .03). Mean 3D vector shifts for patients in the tattoo cohort were 5.6 versus 4.4 mm in the no-tattoo cohort. The average treatment time per fraction for the tattoo VMAT RNI cohort was 23.16 versus 20.82 minutes in the no-tattoo VMAT RNI cohort (P = .08). Mean 3D vector shifts for the patients in the tattoo VMAT cohort were 5.5 versus 7.1 mm in the no-tattoo VMAT cohort. Breath hold technique and body mass index did not affect accuracy in a consistent or clinically relevant way. CONCLUSIONS Using a combination of surface and x-ray imaging, without reference to tattoos, provides excellent accuracy in alignment and setup verification among patients receiving RNI for breast cancer, regardless of treatment technique and with reduced treatment time. Skin-based tattoos are no longer warranted for patients receiving supine RNI.
Collapse
Affiliation(s)
- Drosoula Giantsoudi
- Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts
| | - Arthur Lalonde
- Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts
| | - Colleen Barra
- Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts
| | - Liam Vanbenthuysen
- Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts
| | - Alphonse G Taghian
- Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts
| | - David P Gierga
- Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts
| | - Rachel B Jimenez
- Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts.
| |
Collapse
|
5
|
Sauer TO, Ott OJ, Lahmer G, Fietkau R, Bert C. Prerequisites for the clinical implementation of a markerless SGRT-only workflow for the treatment of breast cancer patients. Strahlenther Onkol 2023; 199:22-29. [PMID: 35788694 PMCID: PMC9839804 DOI: 10.1007/s00066-022-01966-7] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2022] [Accepted: 05/23/2022] [Indexed: 01/18/2023]
Abstract
PURPOSE A markerless workflow for the treatment of breast cancer patients has been introduced and evaluated retrospectively. It includes surface-guided radiation therapy (SGRT)-only positioning for patients with small cone beam CT (CBCT) position corrections during the first five fractions. Prerequisites and the frequency of its clinical application were evaluated, as well as potential benefits in terms of treatment time and dose savings, the frequency of CBCT scans, and the accuracy of the positioning. METHODS A group of 100 patients treated with the new workflow on two Versa HD linacs has been compared to a matched control group of patients treated with the former workflow, which included prepositioning with skin markings and lasers, SGRT and daily CBCT. The comparison was based on the evaluation of logfiles. RESULTS Of the patients treated with the new workflow, 40% did not receive daily CBCT scans. This resulted in mean time savings of 97 s, 166 s and 239 s per fraction for the new workflow, for patients treated without daily CBCT and for SGRT-only fractions, respectively, when compared to the old workflow. Dose savings amounted to a weighted computed tomography dose index reduction of CTDIW = 2.56 cGy on average for normofractionated treatment and weekly CBCTs, while for patients not treated with daily CBCT, SGRT-based positioning accuracy was 5.2 mm for the mean translational magnitude, as evaluated by CBCT. CONCLUSION For 40% of the patients, after five fractions with small CBCT corrections, the workflow could be changed to SGRT-only positioning with weekly CBCT. This leads to imaging dose and time savings and thus also reduced intrafraction motion, potentially increased patient throughput and patient comfort, while assuring appropriate positioning accuracy.
Collapse
Affiliation(s)
- Tim-Oliver Sauer
- Department of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Universitätsstr. 27, 91054 Erlangen, Germany ,Comprehensive Cancer Center Erlangen-EMN, Erlangen, Germany
| | - Oliver J. Ott
- Department of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Universitätsstr. 27, 91054 Erlangen, Germany ,Comprehensive Cancer Center Erlangen-EMN, Erlangen, Germany
| | - Godehard Lahmer
- Department of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Universitätsstr. 27, 91054 Erlangen, Germany ,Comprehensive Cancer Center Erlangen-EMN, Erlangen, Germany
| | - Rainer Fietkau
- Department of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Universitätsstr. 27, 91054 Erlangen, Germany ,Comprehensive Cancer Center Erlangen-EMN, Erlangen, Germany
| | - Christoph Bert
- Department of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Universitätsstr. 27, 91054 Erlangen, Germany ,Comprehensive Cancer Center Erlangen-EMN, Erlangen, Germany
| |
Collapse
|
6
|
Svestad JG, Heydari M, Mikalsen SG, Flote VG, Nordby F, Hellebust TP. Surface-guided positioning eliminates the need for skin markers in radiotherapy of right sided breast cancer: A single center randomized crossover trial. Radiother Oncol 2022; 177:46-52. [PMID: 36309152 DOI: 10.1016/j.radonc.2022.10.017] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2022] [Revised: 09/20/2022] [Accepted: 10/17/2022] [Indexed: 11/06/2022]
Abstract
BACKGROUND AND PURPOSE To prospectively investigate whether surface guided setup of right sided breast cancer patients can increase efficiency and accuracy compared to traditional skin marker/tattoo based setup. MATERIAL AND METHODS Twenty-five patients were included in this study. Each patient was positioned using skin marks and tattoos (procedure A) for half of the fractions and surface guidance using AlignRT (procedure B) for the other half of the fractions. The order of the two procedures was randomized. Pretreatment CBCT was acquired at every fraction for both setup procedures. A total of ten time points were recorded during every treatment session. Applied couch shifts after CBCT match were recorded and used for potential error calculations if no CBCT had been used. RESULTS In the vertical direction procedure B showed significant smaller population based systematic (Ʃ) and random (σ) errors. However, a significant larger systematic error on the individual patient level (M) was also shown. This was found to be due to patient relaxation between setup and CBCT matching. Procedure B also showed a significant smaller random error in the lateral direction, while no significant differences were seen in the longitudinal direction. No significant difference in setup time was found between the two procedures. CONCLUSION Setup of right sided breast cancer patients using surface guidance yields higher accuracy than setup using skin marks/tattoos and lasers with the same setup time. Patient alignment for this patient group can safely be done without the use of permanent tattoos and skin marks when utilizing surface-guided patient positioning. However, CBCT should still be used as final setup verification.
Collapse
Affiliation(s)
| | - Mojgan Heydari
- Department of Medical Physics, Oslo University Hospital, Oslo, Norway
| | | | | | - Fredrik Nordby
- Department of Oncology, Oslo University Hospital, Oslo, Norway
| | - Taran Paulsen Hellebust
- Department of Medical Physics, Oslo University Hospital, Oslo, Norway; Department of Physics, University of Oslo, Norway.
| |
Collapse
|
7
|
Da Silva Mendes V, Reiner M, Huang L, Reitz D, Straub K, Corradini S, Niyazi M, Belka C, Kurz C, Landry G, Freislederer P. ExacTrac Dynamic workflow evaluation: Combined surface optical/thermal imaging and X-ray positioning. J Appl Clin Med Phys 2022; 23:e13754. [PMID: 36001389 DOI: 10.1002/acm2.13754] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2021] [Revised: 07/07/2022] [Accepted: 07/19/2022] [Indexed: 11/09/2022] Open
Abstract
In modern radiotherapy (RT), especially for stereotactic radiotherapy or stereotactic radiosurgery treatments, image guidance is essential. Recently, the ExacTrac Dynamic (EXTD) system, a new combined surface-guided RT and image-guided RT (IGRT) system for patient positioning, monitoring, and tumor targeting, was introduced in clinical practice. The purpose of this study was to provide more information about the geometric accuracy of EXTD and its workflow in a clinical environment. The surface optical/thermal- and the stereoscopic X-ray imaging positioning systems of EXTD was evaluated and compared to cone-beam computed tomography (CBCT). Additionally, the congruence with the radiation isocenter was tested. A Winston Lutz test was executed several times over 1 year, and repeated end-to-end positioning tests were performed. The magnitude of the displacements between all systems, CBCT, stereoscopic X-ray, optical-surface imaging, and MV portal imaging was within the submillimeter range, suggesting that the image guidance provided by EXTD is accurate at any couch angle. Additionally, results from the evaluation of 14 patients with intracranial tumors treated with open-face masks are reported, and limited differences with a maximum of 0.02 mm between optical/thermal- and stereoscopic X-ray imaging were found. As the optical/thermal positioning system showed a comparable accuracy to other IGRT systems, and due to its constant monitoring capability, it can be an efficient tool for detecting intra-fractional motion and for real-time tracking of the surface position during RT.
Collapse
Affiliation(s)
| | - Michael Reiner
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany
| | - Lili Huang
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany
| | - Daniel Reitz
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany
| | - Katrin Straub
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany
| | - Stefanie Corradini
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany
| | - Maximilian Niyazi
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany
| | - Claus Belka
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany.,German Cancer Consortium (DKTK), Partner Site Munich, Munich, Germany
| | - Christopher Kurz
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany
| | - Guillaume Landry
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany
| | - Philipp Freislederer
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany
| |
Collapse
|
8
|
Sauer T, Ott OJ, Lahmer G, Fietkau R, Bert C. Region of interest optimization for radiation therapy of breast cancer. J Appl Clin Med Phys 2021; 22:152-160. [PMID: 34543500 PMCID: PMC8504613 DOI: 10.1002/acm2.13410] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2020] [Revised: 05/11/2021] [Accepted: 08/06/2021] [Indexed: 11/17/2022] Open
Abstract
PURPOSE The goal of this study was to investigate how the choice of the region of interest (ROI) affects the registration results of surface imaging for daily positioning of breast cancer patients. METHODS The AlignRT system (VisionRT, London) and the XVI Cone beam CT (CBCT; Elekta, Stockholm) installed on two Versa HD linacs (Elekta) were used in this study, which included 28 patients (160 fractions). In the clinical workflow, patients were prepositioned with AlignRT and then shifted in 6 degrees of freedom (DOF) according to the CBCT. A new reference capture was taken immediately afterward. Retrospectively, the surface capture resulting from prepositioning was registered to the latest reference capture. By varying the ROI used for registration, the surface-based results were optimized in terms of minimizing the deviation to the clinically applied CBCT shifts. Two sets of ROIs were used: one obtained by applying a variable margin to the breast surface, another by combining ROIs of anatomical structures, including the sternum and contralateral breast. RESULTS Registration results showed significant differences from one ROI to another. Generally, the results improved with increasing ROI size, especially for rotational DOFs. ROIs, including the axilla or supraclavicular lymph drainage region, did not yield an improved registration result. On the other hand, an ROI comprising the breast surface, sternum, and a belt caudal to the breasts decreased the average magnitude of the translational and rotational deviations by 6.6% and 30.8% (p < 0.01), respectively, compared to the breast surface only results. CONCLUSION The influence of the ROI choice on surface imaging registration results was analyzed and the surface-based shifts were compared to clinically applied CBCT shifts. An optimal ROI for the treatment of breast cancer patients, consisting of the breast surface, sternum, and a belt, was identified.
Collapse
Affiliation(s)
- Tim‐Oliver Sauer
- Department of Radiation OncologyUniversitätsklinikum ErlangenFriedrich‐Alexander‐Universität Erlangen‐NürnbergErlangenGermany
| | - Oliver J. Ott
- Department of Radiation OncologyUniversitätsklinikum ErlangenFriedrich‐Alexander‐Universität Erlangen‐NürnbergErlangenGermany
| | - Godehard Lahmer
- Department of Radiation OncologyUniversitätsklinikum ErlangenFriedrich‐Alexander‐Universität Erlangen‐NürnbergErlangenGermany
| | - Rainer Fietkau
- Department of Radiation OncologyUniversitätsklinikum ErlangenFriedrich‐Alexander‐Universität Erlangen‐NürnbergErlangenGermany
| | - Christoph Bert
- Department of Radiation OncologyUniversitätsklinikum ErlangenFriedrich‐Alexander‐Universität Erlangen‐NürnbergErlangenGermany
| |
Collapse
|
9
|
Performance assessment of surface-guided radiation therapy and patient setup in head-and-neck and breast cancer patients based on statistical process control. Phys Med 2021; 89:243-249. [PMID: 34428608 DOI: 10.1016/j.ejmp.2021.08.007] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/05/2021] [Revised: 07/17/2021] [Accepted: 08/10/2021] [Indexed: 02/05/2023] Open
Abstract
PURPOSE To assess the effectiveness of SGRT in clinical applications through statistical process control (SPC). METHODS Taking the patients' positioning through optical surface imaging (OSI) as a process, the average level of process execution was defined as the process mean. Setup errors detected by cone-beam computed tomography (CBCT) and OSI were extracted for head-and-neck cancer (HNC) and breast cancer patients. These data were used to construct individual and exponentially weighted moving average (EWMA) control charts to analyze outlier fractions and small process shifts from the process mean. Using the control charts and process capability indices derived from this process, the patient positioning-related OSI performance and setup error were analyzed for each patient. RESULTS Outlier fractions and small shifts from the process mean that are indicative of setup errors were found to be widely prevalent, with the outliers randomly distributed between fractions. A systematic error of up to 1.6 mm between the OSI and CBCT results was observed in all directions, indicating a significantly degraded OSI performance. Adjusting this systematic error for each patient using setup errors of the first five fractions could effectively mitigate these effects. Process capability analysis following adjustment for systematic error indicated that OSI performance was acceptable (process capability index Cpk = 1.0) for HNC patients but unacceptable (Cpk < 0.75) for breast cancer patients. CONCLUSION SPC is a powerful tool for detecting the outlier fractions and process changes. Our application of SPC to patient-specific evaluations validated the suitability of OSI in clinical applications involving patient positioning.
Collapse
|
10
|
Corradini S, Niyazi M, Verellen D, Valentini V, Walsh S, Grosu AL, Lauber K, Giaccia A, Unger K, Debus J, Pieters BR, Guckenberger M, Senan S, Budach W, Rad R, Mayerle J, Belka C. X-change symposium: status and future of modern radiation oncology-from technology to biology. Radiat Oncol 2021; 16:27. [PMID: 33541387 PMCID: PMC7863262 DOI: 10.1186/s13014-021-01758-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2020] [Accepted: 01/28/2021] [Indexed: 02/06/2023] Open
Abstract
Future radiation oncology encompasses a broad spectrum of topics ranging from modern clinical trial design to treatment and imaging technology and biology. In more detail, the application of hybrid MRI devices in modern image-guided radiotherapy; the emerging field of radiomics; the role of molecular imaging using positron emission tomography and its integration into clinical routine; radiation biology with its future perspectives, the role of molecular signatures in prognostic modelling; as well as special treatment modalities such as brachytherapy or proton beam therapy are areas of rapid development. More clinically, radiation oncology will certainly find an important role in the management of oligometastasis. The treatment spectrum will also be widened by the rational integration of modern systemic targeted or immune therapies into multimodal treatment strategies. All these developments will require a concise rethinking of clinical trial design. This article reviews the current status and the potential developments in the field of radiation oncology as discussed by a panel of European and international experts sharing their vision during the "X-Change" symposium, held in July 2019 in Munich (Germany).
Collapse
Affiliation(s)
- Stefanie Corradini
- Department of Radiation Oncology, University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany.
| | - Maximilian Niyazi
- Department of Radiation Oncology, University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - Dirk Verellen
- Department of Radiotherapy, Iridium Network, Faculty of Medicine and Health Sciences, University of Antwerp, Antwerp, Belgium
| | - Vincenzo Valentini
- Department of Radiation Oncology and Hematology, Fondazione Policlinico Universitario A.Gemelli IRCCS, Università Cattolica S. Cuore, Rome, Italy
| | | | - Anca-L Grosu
- Department of Radiation Oncology, Medical Center, Medical Faculty, University of Freiburg, Freiburg, Germany
- German Cancer Consortium (DKTK), Partner Site Freiburg, Freiburg, Germany
| | - Kirsten Lauber
- Department of Radiation Oncology, University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - Amato Giaccia
- Division of Radiation and Cancer Biology, Department of Radiation Oncology, Stanford University, Stanford, USA
| | - Kristian Unger
- Integrative Biology Group, Helmholtz Zentrum Munich, Munich, Germany
| | - Jürgen Debus
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany
| | - Bradley R Pieters
- Department of Radiation Oncology, Amsterdam University Medical Centers, Location Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - Matthias Guckenberger
- Department of Radiation Oncology, University Hospital of Zurich, University of Zurich, Zurich, Switzerland
| | - Suresh Senan
- Department of Radiation Oncology, Amsterdam University Medical Centers, Location VUmc, Amsterdam, The Netherlands
| | - Wilfried Budach
- Department of Radiation Oncology, Medical Faculty, Heinrich Heine University, Düsseldorf, Germany
| | - Roland Rad
- Center for Translational Cancer Research (TranslaTUM), TU Munich, Munich, Germany
| | - Julia Mayerle
- Department of Internal Medicine II, University Hospital, LMU, Munich, Germany
| | - Claus Belka
- Department of Radiation Oncology, University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| |
Collapse
|
11
|
Nierer L, Walter F, Niyazi M, Shpani R, Landry G, Marschner S, von Bestenbostel R, Dinkel D, Essenbach G, Reiner M, Belka C, Corradini S. Radiotherapy in oncological emergencies: fast-track treatment planning. Radiat Oncol 2020; 15:215. [PMID: 32912293 PMCID: PMC7488151 DOI: 10.1186/s13014-020-01657-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2020] [Accepted: 08/31/2020] [Indexed: 12/12/2022] Open
Abstract
BACKGROUND AND PURPOSE To report on our clinical experience with a newly implemented workflow for radiotherapy (RT) emergency treatments, which allows for a fast treatment application outside the regular working-hours, and its clinical applicability. METHODS Treatment planning of 18 emergency RT patients was carried out using diagnostic computed tomography (CT) without a dedicated RT simulation CT. The cone-beam CT (CBCT) deviations of the first RT treatment were analyzed regarding setup accuracy. Furthermore, feasibility of the "fast-track" workflow was evaluated with respect to dose deviations caused by different Hounsfield unit (HU) to relative electron density (rED) calibrations and RT treatment couch surface shapes via 3D gamma index analysis of exemplary treatment plans. The dosimetric uncertainty introduced by different CT calibrations was quantified. RESULTS Mean patient setup vs. CBCT isocenter deviations were (0.49 ± 0.44) cm (x), (2.68 ± 1.63) cm (y) and (1.80 ± 1.06) cm (z) for lateral, longitudinal and vertical directions, respectively. Three out of four dose comparisons between the emergency RT plan calculated on the diagnostic CT and the same plan calculated on the treatment planning CT showed clinically acceptable gamma passing rates, when correcting for surface artifacts. The maximum difference of rED was 0.054, while most parts of the CT calibration curves coincided well. CONCLUSION In an emergency RT setting, the use of diagnostic CT data for treatment planning might be time-saving and was shown to be suitable for many cases, considering reproducibility of patient setup, accuracy of initial patient setup and accuracy of dose-calculation.
Collapse
Affiliation(s)
- Lukas Nierer
- Department of Radiation Oncology, University Hospital, LMU Munich, Marchioninistr. 15, 81377 Munich, Germany
| | - Franziska Walter
- Department of Radiation Oncology, University Hospital, LMU Munich, Marchioninistr. 15, 81377 Munich, Germany
| | - Maximilian Niyazi
- Department of Radiation Oncology, University Hospital, LMU Munich, Marchioninistr. 15, 81377 Munich, Germany
| | - Roel Shpani
- Department of Radiation Oncology, University Hospital, LMU Munich, Marchioninistr. 15, 81377 Munich, Germany
| | - Guillaume Landry
- Department of Radiation Oncology, University Hospital, LMU Munich, Marchioninistr. 15, 81377 Munich, Germany
| | - Sebastian Marschner
- Department of Radiation Oncology, University Hospital, LMU Munich, Marchioninistr. 15, 81377 Munich, Germany
| | - Rieke von Bestenbostel
- Department of Radiation Oncology, University Hospital, LMU Munich, Marchioninistr. 15, 81377 Munich, Germany
| | - Dominika Dinkel
- Department of Radiation Oncology, University Hospital, LMU Munich, Marchioninistr. 15, 81377 Munich, Germany
| | - Gabriela Essenbach
- Department of Radiation Oncology, University Hospital, LMU Munich, Marchioninistr. 15, 81377 Munich, Germany
| | - Michael Reiner
- Department of Radiation Oncology, University Hospital, LMU Munich, Marchioninistr. 15, 81377 Munich, Germany
| | - Claus Belka
- Department of Radiation Oncology, University Hospital, LMU Munich, Marchioninistr. 15, 81377 Munich, Germany
| | - Stefanie Corradini
- Department of Radiation Oncology, University Hospital, LMU Munich, Marchioninistr. 15, 81377 Munich, Germany
| |
Collapse
|
12
|
Freislederer P, Kügele M, Öllers M, Swinnen A, Sauer TO, Bert C, Giantsoudi D, Corradini S, Batista V. Recent advanced in Surface Guided Radiation Therapy. Radiat Oncol 2020; 15:187. [PMID: 32736570 PMCID: PMC7393906 DOI: 10.1186/s13014-020-01629-w] [Citation(s) in RCA: 66] [Impact Index Per Article: 16.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2020] [Accepted: 07/21/2020] [Indexed: 01/27/2023] Open
Abstract
The growing acceptance and recognition of Surface Guided Radiation Therapy (SGRT) as a promising imaging technique has supported its recent spread in a large number of radiation oncology facilities. Although this technology is not new, many aspects of it have only recently been exploited. This review focuses on the latest SGRT developments, both in the field of general clinical applications and special techniques.SGRT has a wide range of applications, including patient positioning with real-time feedback, patient monitoring throughout the treatment fraction, and motion management (as beam-gating in free-breathing or deep-inspiration breath-hold). Special radiotherapy modalities such as accelerated partial breast irradiation, particle radiotherapy, and pediatrics are the most recent SGRT developments.The fact that SGRT is nowadays used at various body sites has resulted in the need to adapt SGRT workflows to each body site. Current SGRT applications range from traditional breast irradiation, to thoracic, abdominal, or pelvic tumor sites, and include intracranial localizations.Following the latest SGRT applications and their specifications/requirements, a stricter quality assurance program needs to be ensured. Recent publications highlight the need to adapt quality assurance to the radiotherapy equipment type, SGRT technology, anatomic treatment sites, and clinical workflows, which results in a complex and extensive set of tests.Moreover, this review gives an outlook on the leading research trends. In particular, the potential to use deformable surfaces as motion surrogates, to use SGRT to detect anatomical variations along the treatment course, and to help in the establishment of personalized patient treatment (optimized margins and motion management strategies) are increasingly important research topics. SGRT is also emerging in the field of patient safety and integrates measures to reduce common radiotherapeutic risk events (e.g. facial and treatment accessories recognition).This review covers the latest clinical practices of SGRT and provides an outlook on potential applications of this imaging technique. It is intended to provide guidance for new users during the implementation, while triggering experienced users to further explore SGRT applications.
Collapse
Affiliation(s)
- P. Freislederer
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany
| | - M. Kügele
- Department of Hematology, Oncology and Radiation Physics, Skåne University Hospital, Lund, Sweden
- Medical Radiation Physics, Department of Clinical Sciences, Lund University, Lund, Sweden
| | - M. Öllers
- Maastricht Radiation Oncology (MAASTRO), Maastricht, the Netherlands
| | - A. Swinnen
- Maastricht Radiation Oncology (MAASTRO), Maastricht, the Netherlands
| | - T.-O. Sauer
- Department of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - C. Bert
- Department of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - D. Giantsoudi
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, USA
| | - S. Corradini
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany
| | - V. Batista
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, Germany
- National Center for Tumor diseases (NCT), Heidelberg, Germany
| |
Collapse
|
13
|
Reitz D, Walter F, Schönecker S, Freislederer P, Pazos M, Niyazi M, Landry G, Alongi F, Bölke E, Matuschek C, Reiner M, Belka C, Corradini S. Stability and reproducibility of 6013 deep inspiration breath-holds in left-sided breast cancer. Radiat Oncol 2020; 15:121. [PMID: 32448224 PMCID: PMC7247126 DOI: 10.1186/s13014-020-01572-w] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2019] [Accepted: 05/17/2020] [Indexed: 12/25/2022] Open
Abstract
Purpose Patients with left-sided breast cancer frequently receive deep inspiration breath-hold (DIBH) radiotherapy to reduce the risk of cardiac side effects. The aim of the present study was to analyze intra-breath-hold stability and inter-fraction breath-hold reproducibility in clinical practice. Material and methods Overall, we analyzed 103 patients receiving left-sided breast cancer radiotherapy using a surface-guided DIBH technique. During each treatment session the vertical motion of the patient was continuously measured by a surface guided radiation therapy (SGRT) system and automated gating control (beam on/off) was performed using an audio-visual patient feedback system. Dose delivery was automatically triggered when the tracking point was within a predefined gating window. Intra-breath-hold stability and inter-fraction reproducibility across all fractions of the entire treatment course were analyzed per patient. Results In the present series, 6013 breath-holds during beam-on time were analyzed. The mean amplitude of the gating window from the baseline breathing curve (maximum expiration during free breathing) was 15.8 mm (95%-confidence interval: [8.5–30.6] mm) and had a width of 3.5 mm (95%-CI: [2–4.3] mm). As a measure of intra-breath-hold stability, the median standard deviation of the breath-hold level during DIBH was 0.3 mm (95%-CI: [0.1–0.9] mm). Similarly, the median absolute intra-breath-hold linear amplitude deviation was 0.4 mm (95%-CI: [0.01–2.1] mm). Reproducibility testing showed good inter-fractional reliability, as the maximum difference in the breathing amplitudes in all patients and all fractions were 1.3 mm on average (95%-CI: [0.5–2.6] mm). Conclusion The clinical integration of an optical surface scanner enables a stable and reliable DIBH treatment delivery during SGRT for left-sided breast cancer in clinical routine.
Collapse
Affiliation(s)
- D Reitz
- Department of Radiation Oncology, University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - F Walter
- Department of Radiation Oncology, University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - S Schönecker
- Department of Radiation Oncology, University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - P Freislederer
- Department of Radiation Oncology, University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - M Pazos
- Department of Radiation Oncology, University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - M Niyazi
- Department of Radiation Oncology, University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - G Landry
- Department of Radiation Oncology, University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - F Alongi
- Advanced Radiation Oncology Department, IRCCS Sacro Cuore Don Calabria Hospital, Negrar-Verona, Italy.,University of Brescia, Brescia, Italy
| | - E Bölke
- Department of Radiation Oncology, University Hospital Düsseldorf, Düsseldorf, Germany
| | - C Matuschek
- Department of Radiation Oncology, University Hospital Düsseldorf, Düsseldorf, Germany
| | - M Reiner
- Department of Radiation Oncology, University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - C Belka
- Department of Radiation Oncology, University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - S Corradini
- Department of Radiation Oncology, University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany.
| |
Collapse
|