1
|
Awadhare P, Patel R, McCallin T, Mainali K, Jackson K, Starke H, Bhalala U. Non-invasive Cardiac Output Monitoring and Assessment of Fluid Responsiveness in Children With Shock in the Emergency Department. Front Pediatr 2022; 10:857106. [PMID: 35463892 PMCID: PMC9021702 DOI: 10.3389/fped.2022.857106] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/18/2022] [Accepted: 03/04/2022] [Indexed: 11/20/2022] Open
Abstract
INTRODUCTION The assessment of fluid responsiveness is important in the management of shock but conventional methods of assessing fluid responsiveness are often inaccurate. Our study aims to evaluate changes in objective hemodynamic parameters as measured using electrical cardiometry (ICON® monitor) following the fluid bolus in children presenting with shock and to evaluate whether any specific hemodynamic parameter can best predict fluid responsiveness among children with shock. MATERIALS AND METHODS We conducted a prospective observational study in children presenting with shock to our emergency department between June 2020 and March 2021. We collected the parameters such as heart rate (HR), respiratory rate (RR), systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial pressure (MAP), and hemodynamic data such as cardiac output CO), cardiac index (CI), index of contractility (ICON), stroke volume (SV), stroke index (SI), corrected flow time (FTC), systolic time ratio (STR), variation of index of contractility (VIC), stroke volume variation (SVV), systemic vascular resistance (SVR), and thoracic fluid content (TFC) using the ICON monitor before and after fluid bolus (FB). We assessed percent change (Δ) and used paired-sample Student's t-test to compare pre- and post-hemodynamic data and Mann-Whitney U-test to compare fluid responders and non-responders. P-Values < 0.05 were considered statistically significant. RESULTS We recorded 42 fluid interventions in 40 patients during our study period. The median IQR age was 10.56 (4.8, 14.8) years with male/female ratio (1.2:1). There was a significant decrease in ΔRR [-1.61 (-14.8, 0); p = 0.012], ΔDBP [-5.5 (-14.4, 8); p = 0.027], ΔMAP [-2.2 (-11, 2); p = 0.018], ΔSVR [-5.8 (-20, 5.2); p = 0.025], and ΔSTR [-8.39 (-21, 3); p = 0.001] and significant increase in ΔTFC [6.2 (3.5, 11.4); p = 0.01] following FB. We defined fluid responders by an increase in SV by ≥10% after a single FB of 20 ml/kg crystalloid. Receiver operating curve analysis revealed that among all the parameters, 15% change in ICON had an excellent AUC (0.85) for the fluid responsiveness. CONCLUSION Our study showed significant changes in objective hemodynamic parameters, such as SVR, STR, and TFC following FB in children presenting with shock. A 15% change in ICON had an excellent predictive performance for the fluid responsiveness among our cohort of pediatric shock.
Collapse
Affiliation(s)
- Pranali Awadhare
- The Children's Hospital of San Antonio, San Antonio, TX, United States
| | - Radha Patel
- University of the Incarnate Word School of Osteopathic Medicine, San Antonio, TX, United States
| | - Tracy McCallin
- Department of Pediatrics, University Hospitals Rainbow Babies and Children's Hospital, Cleveland, OH, United States
| | - Kiran Mainali
- University of the Incarnate Word School of Osteopathic Medicine, San Antonio, TX, United States
| | - Kelly Jackson
- The Children's Hospital of San Antonio, San Antonio, TX, United States
| | - Hannah Starke
- The Children's Hospital of San Antonio, San Antonio, TX, United States
| | - Utpal Bhalala
- Driscoll Children's Hospital, Corpus Christi, TX, United States.,Department of Pediatrics, Texas A&M University, College Station, TX, United States.,Department of Anesthesiology and Critical Care Medicine, University of Texas Medical Branch, Galveston, TX, United States
| |
Collapse
|
2
|
Slagt C, Servaas S, Ketelaars R, van Geffen GJ, Tacken MCT, Verrips CA, Baggen LAM, Scheffer GJ, van Eijk LT. Non-invasive electrical cardiometry cardiac output monitoring during prehospital helicopter emergency medical care: a feasibility study. J Clin Monit Comput 2021; 36:363-370. [PMID: 33486570 PMCID: PMC9122859 DOI: 10.1007/s10877-021-00657-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2020] [Accepted: 01/08/2021] [Indexed: 11/24/2022]
Abstract
Purpose Introducing advanced hemodynamic monitoring might be beneficial during Helicopter Emergency Medical Service (HEMS) care. However, it should not increase the on-scene-time, it should be easy to use and should be non-invasive. The goal of this study was to investigate the feasibility of non-invasive cardiac output measurements by electrical cardiometry (EC) and the quality of the EC signal during pre-hospital care provided by our HEMS. Methods A convenience sample of fifty patients who required HEMS assistance were included in this study. Problems with respect to connecting the patient, entering patient characteristics and measuring were inventoried. Quality of EC signal of the measurements was assessed during prehospital helicopter care. We recorded the number of measurements with a signal quality indicator (SQI) ≥ 80 and the number of patients having at least 1 measurement with a SQI ≥ 80. Furthermore, the SQI value distribution of the measurements within each patient was analysed. Results In the experience of the attending HEMS caregivers application of the device was easy and did not result in increased duration of on-scene time. Patch adhesion was reported as a concern due to clammy skin in 22% of all cases. 684 measurements were recorded during HEMS care. In 47 (94%) patients at least 1 measurement with an SQI ≥ 80 was registered. Of all recorded measurements 5.8% had an SQI < 40, 11.4% had an SQI 40–59, 14.9% had a SQI between 60 and 79 and 67.8% had SQI ≥ 80. Conclusion Cardiac output measurements are feasible during prehospital HEMS care with good quality of the EC signal. Monitoring was easy to use and quick to install. In our view it is an promising candidate for the prehospital setting. Further research is needed to determine its clinical value during clinical decision making.
Collapse
Affiliation(s)
- Cornelis Slagt
- Department of Anesthesiology, Pain and Palliative Medicine, Radboud University Nijmegen Medical Centre, Geert Grooteplein Zuid 10, Huispost 717, route 714, Postbus 9101, 6500 HB, Nijmegen, The Netherlands. .,Helicopter Emergency Medical Service Lifeliner 3, Geert Grooteplein Zuid 10, 6500 HB, Nijmegen, The Netherlands.
| | - Sjoerd Servaas
- Department of Anesthesiology, Pain and Palliative Medicine, Radboud University Nijmegen Medical Centre, Geert Grooteplein Zuid 10, Huispost 717, route 714, Postbus 9101, 6500 HB, Nijmegen, The Netherlands
| | - Rein Ketelaars
- Department of Anesthesiology, Pain and Palliative Medicine, Radboud University Nijmegen Medical Centre, Geert Grooteplein Zuid 10, Huispost 717, route 714, Postbus 9101, 6500 HB, Nijmegen, The Netherlands.,Helicopter Emergency Medical Service Lifeliner 3, Geert Grooteplein Zuid 10, 6500 HB, Nijmegen, The Netherlands
| | - Geert-Jan van Geffen
- Department of Anesthesiology, Pain and Palliative Medicine, Radboud University Nijmegen Medical Centre, Geert Grooteplein Zuid 10, Huispost 717, route 714, Postbus 9101, 6500 HB, Nijmegen, The Netherlands.,Helicopter Emergency Medical Service Lifeliner 3, Geert Grooteplein Zuid 10, 6500 HB, Nijmegen, The Netherlands
| | - Marijn Cornelia Theresia Tacken
- Department of Anesthesiology, Pain and Palliative Medicine, Radboud University Nijmegen Medical Centre, Geert Grooteplein Zuid 10, Huispost 717, route 714, Postbus 9101, 6500 HB, Nijmegen, The Netherlands.,Helicopter Emergency Medical Service Lifeliner 3, Geert Grooteplein Zuid 10, 6500 HB, Nijmegen, The Netherlands
| | - Corien Alexandra Verrips
- Helicopter Emergency Medical Service Lifeliner 3, Geert Grooteplein Zuid 10, 6500 HB, Nijmegen, The Netherlands
| | - Lonneke Ankie Marcel Baggen
- Department of Anesthesiology, Pain and Palliative Medicine, Radboud University Nijmegen Medical Centre, Geert Grooteplein Zuid 10, Huispost 717, route 714, Postbus 9101, 6500 HB, Nijmegen, The Netherlands
| | - Gert Jan Scheffer
- Department of Anesthesiology, Pain and Palliative Medicine, Radboud University Nijmegen Medical Centre, Geert Grooteplein Zuid 10, Huispost 717, route 714, Postbus 9101, 6500 HB, Nijmegen, The Netherlands.,Helicopter Emergency Medical Service Lifeliner 3, Geert Grooteplein Zuid 10, 6500 HB, Nijmegen, The Netherlands
| | - Lucas Theodorus van Eijk
- Department of Anesthesiology, Pain and Palliative Medicine, Radboud University Nijmegen Medical Centre, Geert Grooteplein Zuid 10, Huispost 717, route 714, Postbus 9101, 6500 HB, Nijmegen, The Netherlands
| |
Collapse
|