1
|
Cavalcanti Kußmaul A, Baur N, Wulf J, Greiner A, Neudeck R, Kistler M, Neuerburg C, Böcker W, Becker CA. Motion preservation for open book injuries of the pubic symphysis -a biomechanical cadaver study. Arch Orthop Trauma Surg 2024; 144:2665-2671. [PMID: 38801533 PMCID: PMC11211126 DOI: 10.1007/s00402-024-05390-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/23/2024] [Accepted: 05/17/2024] [Indexed: 05/29/2024]
Abstract
INTRODUCTION Open book injuries are challenging injuries that oftentimes require surgical treatment. Currently, treatment is performed with symphyseal plating requiring extensive surgery and entirely limiting physiological movement of the symphyseal joint, frequently resulting in implant failure. Therefore, we investigated the biomechanical properties of a minimally invasive tape suture construct (modified SpeedBridge™) as an alternative stabilization technique for the treatment of open book injuries in human cadaver pelvic rings. MATERIALS AND METHODS The symphysis of 9 human cadaver pelvises was dissected and dilated to 3 cm creating an open book injury. Next, the two osteosynthesis methods (plating, modified SpeedBridge™) were applied. All specimens then underwent cyclic horizontal and vertical loading, simulating biomechanical forces while sitting, standing and walking. For statistical analysis, 3D dislocation (mm) was calculated. RESULTS Total displacement (mm) of the pubic symphysis displayed the following means and standard deviations: native group 1.34 ± 0.62 mm, open book group 3.01 ± 1.26 mm, tape group 1.94 ± 0.59 mm and plate group 1.37 ± 0.41 mm. Comparison between native and open book (p = 0.029), open book and plate (p = 0.004), open book and tape (p = 0.031), as well as tape and plate group (p = 0.002) showed significant differences. No significant differences were found when comparing the native and tape (p = 0.059), as well as the native and plate (p = 0.999) group. CONCLUSION While both osteosynthesis techniques sufficiently stabilized the injury, symphyseal plating displayed the highest rigidity. The modified SpeedBridge™ as a tape suture construct provided statistically sufficient biomechanical stability while maintaining symphyseal micro mobility, consequently allowing ligamental healing of the injured joint without iatrogenic arthrodesis.
Collapse
Affiliation(s)
- Adrian Cavalcanti Kußmaul
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), LMU University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany.
| | - Nele Baur
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), LMU University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - Jan Wulf
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), LMU University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - Axel Greiner
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), LMU University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - Rouven Neudeck
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), LMU University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - Manuel Kistler
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), LMU University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - Carl Neuerburg
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), LMU University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - Wolfgang Böcker
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), LMU University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - Christopher A Becker
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), LMU University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| |
Collapse
|
2
|
Cavalcanti Kußmaul A, Schwaabe F, Becker CA, Kleber C, Linhart C, Thorwächter C, Rubenbauer B, Böcker W, Greiner A. Does augmentation increase the pull-out force of symphyseal screws? A biomechanical cadaver study. Eur J Trauma Emerg Surg 2022; 48:4215-4221. [PMID: 35364692 PMCID: PMC9532288 DOI: 10.1007/s00068-022-01963-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2022] [Accepted: 03/17/2022] [Indexed: 11/28/2022]
Abstract
Purpose Open reduction and internal fixation using anterior plate osteosynthesis currently represents the gold standard for the treatment of symphyseal disruptions. Since postoperative screw loosening with consequent implant failure is frequently observed, this study aims to evaluate if and to what extent augmentation can increase the pull-out force of symphyseal screws to improve the constructs stability. Methods Twelve human cadaveric anterior pelvic rings were separated at the symphyseal joint for bilateral testing, consequently achieving comparable sites. First, one non-augmented screw was drilled into the superior pubic ramus, whereas the contralateral side was primarily augmented. The screws were then withdrawn with a constant speed of 10 mm/min and the fixation strengths determined by the force (N) displacement (mm) curve. Finally, the primary non-augmented site was secondary augmented, representing revision surgery after initial implant failure, and the corresponding fixation strength was measured again. Results Augmentation compared to non-augmented screws displayed significantly higher pull-out forces with an increase in pull-out force by 377% for primary and 353% for secondary augmentation (p < 0.01). There was no significant difference in the pull-out force comparing primary and secondary augmentation (p = 0.74). Conclusions Primary and secondary augmentation significantly increases the stability of symphyseal screws and, therefore, potentially decreases rates of implant failure. Supplementary Information The online version contains supplementary material available at 10.1007/s00068-022-01963-6.
Collapse
Affiliation(s)
- Adrian Cavalcanti Kußmaul
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany.
| | - Fanny Schwaabe
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - Christopher Alexander Becker
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - Christian Kleber
- Department of Orthopaedics, Trauma and Plastic Surgery, University Hospital Leipzig, Liebigstraße 20, 04103, Leipzig, Germany
| | - Christoph Linhart
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - Christoph Thorwächter
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - Bianka Rubenbauer
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - Wolfgang Böcker
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - Axel Greiner
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| |
Collapse
|