1
|
Wu Y, He J, Han X, Xu Q, Dai H, Wu J. Application of an autotransfusion pressure control system in blood salvage. J Int Med Res 2023; 51:3000605231206963. [PMID: 38017365 PMCID: PMC10686018 DOI: 10.1177/03000605231206963] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2022] [Accepted: 09/25/2023] [Indexed: 11/30/2023] Open
Abstract
OBJECTIVE This study was performed to evaluate the effect of a homemade autotransfusion pressure-control system on the regulation of negative pressure and to clarify the influence of different negative pressures on the recovered erythrocytes. METHODS Fifty patients were randomly divided into five groups, and five different suction-generated negative pressures were applied. Before suction, 6 mL of blood was collected from the surgical field; after suction, 6 mL of blood was collected from the blood storage tank. The hemoglobin, hematocrit, mean corpuscular volume, newly generated standardized plasma free hemoglobin, and change in the hemolysis rate of erythrocytes before and after suction were compared. Additionally, the erythrocyte morphology was observed. RESULTS The hemoglobin and hematocrit were significantly different before and after suction in all five groups. As the suction pressure increased, gradual increases were noted in the number of abnormal erythrocytes in the field of view, the newly generated standardized plasma free hemoglobin, and the change in the hemolysis rate. CONCLUSIONS The destruction rate of erythrocytes increased as the suction-generated negative pressure increased. When using a pressure-control system, a negative pressure of <200 mmHg should be applied to reduce the damage to the autotransfused blood.
Collapse
Affiliation(s)
- Yini Wu
- Department of Anesthesiology, People’s Hospital of Lishui, Lishui, Zhejiang, China
| | - Jiaqun He
- Department of Anesthesiology, People’s Hospital of Haiyan, Haiyan, Zhejiang, China
| | - Xin Han
- Department of Anesthesiology, People’s Hospital of Lishui, Lishui, Zhejiang, China
| | - Qiaomin Xu
- Department of Anesthesiology, People’s Hospital of Lishui, Lishui, Zhejiang, China
| | - Hong Dai
- Department of Anesthesiology, People’s Hospital of Lishui, Lishui, Zhejiang, China
| | - Jimin Wu
- Department of Anesthesiology, People’s Hospital of Lishui, Lishui, Zhejiang, China
| |
Collapse
|
2
|
Hanekop G, Kollmeier JM, Frahm J, Iwanowski I, Khabbazzadeh S, Kutschka I, Tirilomis T, Ulrich C, Friedrich MG. Turbulence in surgical suction heads as detected by MRI. THE JOURNAL OF EXTRA-CORPOREAL TECHNOLOGY 2023; 55:70-81. [PMID: 37378439 DOI: 10.1051/ject/2023015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/22/2022] [Accepted: 04/06/2023] [Indexed: 06/29/2023]
Abstract
BACKGROUND Blood loss is common during surgical procedures, especially in open cardiac surgery. Allogenic blood transfusion is associated with increased morbidity and mortality. Blood conservation programs in cardiac surgery recommend re-transfusion of shed blood directly or after processing, as this decreases transfusion rates of allogenic blood. But aspiration of blood from the wound area is often associated with increased hemolysis, due to flow induced forces, mainly through development of turbulence. METHODS We evaluated magnetic resonance imaging (MRI) as a qualitative tool for detection of turbulence. MRI is sensitive to flow; this study uses velocity-compensated T1-weighted 3D MRI for turbulence detection in four geometrically different cardiotomy suction heads under comparable flow conditions (0-1250 mL/min). RESULTS Our standard control suction head Model A showed pronounced signs of turbulence at all flow rates measured, while turbulence was only detectable in our modified Models 1-3 at higher flow rates (Models 1 and 3) or not at all (Model 2). CONCLUSIONS The comparison of flow performance of surgical suction heads with different geometries via acceleration-sensitized 3D MRI revealed significant differences in turbulence development between our standard control Model A and the modified alternatives (Models 1-3). As flow conditions during measurement have been comparable, the specific geometry of the respective suction heads must have been the main factor responsible. The underlying mechanisms and causative factors can only be speculated about, but as other investigations have shown, hemolytic activity is positively associated with degree of turbulence. The turbulence data measured in this study correlate with data from other investigations about hemolysis induced by surgical suction heads. The experimental MRI technique used showed added value for further elucidating the underlying physical phenomena causing blood damage due to non-physiological flow.
Collapse
Affiliation(s)
- Gunnar Hanekop
- Department of Anesthesiology, Intensive Care, Emergency Medicine, Pain Therapy, University Medicine, Georg-August-University, Robert-Koch-Strasse 40, 37075 Goettingen, Germany
| | - Jost M Kollmeier
- Max-Planck-Institute for Multidisciplinary Sciences, Am Faßberg 11, 37077 Goettingen, Germany
| | - Jens Frahm
- Max-Planck-Institute for Multidisciplinary Sciences, Am Faßberg 11, 37077 Goettingen, Germany
| | - Ireneusz Iwanowski
- Department of Heart-Thoracic- and Vascular-Surgery, University Medicine, Georg-August-University, Robert-Koch-Strasse 40, 37075 Goettingen, Germany
| | - Sepideh Khabbazzadeh
- Department of Anesthesiology, Intensive Care, Emergency Medicine, Pain Therapy, University Medicine, Georg-August-University, Robert-Koch-Strasse 40, 37075 Goettingen, Germany
| | - Ingo Kutschka
- Department of Heart-Thoracic- and Vascular-Surgery, University Medicine, Georg-August-University, Robert-Koch-Strasse 40, 37075 Goettingen, Germany
| | - Theodor Tirilomis
- Department of Heart-Thoracic- and Vascular-Surgery, University Medicine, Georg-August-University, Robert-Koch-Strasse 40, 37075 Goettingen, Germany
| | - Christian Ulrich
- Department of Heart-Thoracic- and Vascular-Surgery, University Medicine, Georg-August-University, Robert-Koch-Strasse 40, 37075 Goettingen, Germany
| | - Martin G Friedrich
- Department of Heart-Thoracic- and Vascular-Surgery, University Medicine, Georg-August-University, Robert-Koch-Strasse 40, 37075 Goettingen, Germany
| |
Collapse
|
3
|
Erdoes G, von Stegmann Und Stein C, Eberle B, Gerber D. Acid citrate dextrose formula A versus unfractionated heparin for anticoagulation of salvaged red blood cells in cardiac surgery. J Card Surg 2022; 37:5608-5612. [PMID: 36378941 DOI: 10.1111/jocs.17173] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Accepted: 10/29/2022] [Indexed: 11/16/2022]
Abstract
Red blood cell salvage plays an important role in reducing the use of allogeneic blood transfusion during cardiac surgery. While there is consensus as to the benefit of employing cell salvage systems, there are no clear recommendations on the anticoagulant used for salvaged blood. In eight patients undergoing elective cardiac surgery at our university hospital's cardiovascular center, the authors describe hemodynamic effects of salvaged autologous blood transfusion when either unfractionated heparin or acid citrate dextrose formula A was used as the anticoagulant. Mean arterial pressure, heart rate, central venous pressure and acid-base status of the autologous red blood cell concentrate were compared between patients receiving autologous blood anticoagulated with acid citrate dextrose formula A versus unfractionated heparin. A clinically relevant decrease in mean arterial pressure (median change, - 19 mmHg [min -29; max -1] and marked acidosis [group median <6.30 [<6.30; 6.49] was observed in group acid citrate dextrose formula A. Acid citrate dextrose formula A anticoagulant for autologous red blood cell salvage has the potential to cause major adverse hemodynamic events during free-flowing re-transfusion of autologous red blood cell concentrate. Acute ionized hypocalcemia and acidemia may ensue from residual citrate in the supernatant of red blood cell concentrate reconstituted in unbuffered saline.
Collapse
Affiliation(s)
- Gabor Erdoes
- Department of Anesthesiology and Pain Medicine, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse, Bern, Switzerland
| | - Christiane von Stegmann Und Stein
- Department of Anesthesiology and Pain Medicine, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse, Bern, Switzerland
| | - Balthasar Eberle
- Department of Anesthesiology and Pain Medicine, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse, Bern, Switzerland
| | - Daniel Gerber
- Department of Anesthesiology and Pain Medicine, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse, Bern, Switzerland
| |
Collapse
|
4
|
Münch F, Purbojo A, Wenzel F, Kohl M, Dittrich S, Rauh M, Zimmermann R, Kwapil N. [Improved quality of stored packed red blood cells by mechanical rinsing]. DIE ANAESTHESIOLOGIE 2022; 71:882-892. [PMID: 35969253 PMCID: PMC9636120 DOI: 10.1007/s00101-022-01189-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/26/2021] [Revised: 07/03/2022] [Accepted: 07/12/2022] [Indexed: 06/15/2023]
Abstract
BACKGROUND The transfusion of packed red blood cells (PRBC) is associated with various side effects, including storage damage to PRBCs. The cells change their structure, releasing potassium as well as lactate. Mechanical rinsing, available in many hospitals, is able to remove toxic substances and possibly minimizes the negative side effects of transfusion. OBJECTIVE The primary aim of our study was to improve the quality of PRBCs before transfusion. The effects of different washing solutions on PRBC quality were analyzed. MATERIAL AND METHODS This in vitro study compares 30 mechanically washed PRBCs. They were either processed with standard normal saline 0.9% (n = 15, N group) or a hemofiltration solution containing 4 mmol/l potassium (n = 15, HF group) by a mechanical rinsing device (Xtra, LivaNova, Munich, Germany). A subgroup analysis was performed based on the storage duration of the processed PRBCs (7, 14, 37 days). Samples were taken before washing (EKprä), immediately after washing (EKpost) and 10 h later (EKpost10h), after storage in the "wash medium" at room temperature. Concentrations of ATP (probability of survival in transfused erythrocytes), lactate, citrate and electrolytes (potassium, sodium, chloride, calcium) were tested. RESULTS AND CONCLUSION Mechanical rinsing improves pretransfusion quality of PRBC. Washing with a hemofiltration solution results in a more physiological electrolyte composition. Even 10 h after mechanical rinsing with a hemofiltration solution, the quality of 37-day-old PRBC is comparable to young PRBC that have been stored for 7 days and have not been washed. Washing stored PRBC increases the ATP content, which subsequently leads to an increased probability of survival of red cells after transfusion.
Collapse
Affiliation(s)
- F Münch
- Kinderherzchirurgische Abteilung, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Loschgestraße 15, 91054, Erlangen, Deutschland.
| | - A Purbojo
- Kinderherzchirurgische Abteilung, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Loschgestraße 15, 91054, Erlangen, Deutschland
| | - F Wenzel
- Fakultät Medical and Life Science, Hochschule Furtwangen University Campus Villingen-Schwenningen, Jakob-Kienzle-Str. 17, 78054, Villingen-Schwenningen, Deutschland
| | - M Kohl
- Fakultät Medical and Life Science, Hochschule Furtwangen University Campus Villingen-Schwenningen, Jakob-Kienzle-Str. 17, 78054, Villingen-Schwenningen, Deutschland
| | - S Dittrich
- Kinderkardiologische Abteilung, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Loschgestraße 15, 91054, Erlangen, Deutschland
| | - M Rauh
- Klinisches Labor der Kinder- und Jugendklinik, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Loschgestraße 15, 91054, Erlangen, Deutschland
| | - R Zimmermann
- Transfusionsmedizinische und Hämostaseologische Abteilung, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Krankenhausstraße 12, 91054, Erlangen, Deutschland
| | - N Kwapil
- Kinderherzchirurgische Abteilung, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Loschgestraße 15, 91054, Erlangen, Deutschland
| |
Collapse
|
5
|
Cell Salvage in Oncological Surgery, Peripartum Haemorrhage and Trauma. SURGERIES 2022. [DOI: 10.3390/surgeries3010007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Oncological surgery, obstetric haemorrhage and severe trauma are the most challenging conditions for establishing clinical recommendations for the use of cell salvage. When the likelihood of allogeneic transfusion is high, the intraoperative use of this blood-saving technique would be justified, but specific patient selection criteria are needed. The main concerns in the case of oncological surgery are the reinfusion of tumour cells, thereby increasing the risk of metastasis. This threat could be minimized, which may help to rationalize its indication. In severe peripartum haemorrhage, cell salvage has not proven cost-effective, damage control techniques have been developed, and, given the risk of fetomaternal alloimmunization and amniotic fluid embolism, it is increasingly out of use. In trauma, bleeding may originate from multiple sites, coagulopathy may develop, and it should be evaluated whether re-transfusion of autologous blood collected from uncontaminated organ cavities would be feasible. General safety measures include washing recovered blood and its passage through leukocyte depletion filters. To date, no well-defined indications for cell salvage have been established for these pathologies, but with accurate case selection and selective implementation, it could become safe and effective. Randomized clinical trials are urgently needed.
Collapse
|
6
|
[Perioperative patient blood management in the aged-more than only transfusion? : Review of the 4th symposium of the working group on anemia on the occasion of the annual meeting of the German Geriatric Society in Frankfurt 2019]. Z Gerontol Geriatr 2020; 53:233-238. [PMID: 32065249 DOI: 10.1007/s00391-020-01708-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2019] [Accepted: 02/03/2020] [Indexed: 10/25/2022]
Abstract
Anemia is frequent in older people with one in two geriatric inpatients being affected. Therefore, in elective surgery, such as endoprosthetic treatment it is very likely that anemia is already present in a preoperative setting. So far there are no particular guidelines about perioperative management of anemia in geriatric patients. The existing recommendations of the Patient Blood Management (PBM) network cooperation and the current Association of the Scientific Medical Societies in Germany (AWMF) S3 guidelines on preoperative anemia refer to all patients aged >18 years but without particular consideration of the growing number of oldest old orthogeriatric patients. This is more problematic as anemia in the aged has been shown to be different from anemia in younger patients in terms of diagnostics and treatment. Based on several interdisciplinary lectures, this year the symposium of the working group on anemia of the German Geriatric Society (DGG) focused on the problems of perioperative PBM in orthogeriatric patients and encouraged the discussion about developing PBM treatment recommendations for this patient group.
Collapse
|
7
|
[Mortality after high-risk surgery in Jehovah's Witness patients]. Anaesthesist 2019; 68:444-455. [PMID: 31236704 DOI: 10.1007/s00101-019-0617-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2019] [Revised: 05/21/2019] [Accepted: 05/28/2019] [Indexed: 10/26/2022]
Abstract
BACKGROUND Jehovah's Witness (JW) patients strictly refuse allogeneic blood transfusion for religious reasons. Nevertheless, JW also wish to benefit from modern therapeutic concepts including major surgical procedures without facing an excessive risk of death. The Northwest Hospital in Frankfurt am Main Germany is a confidential clinic of JW and performs approximately 100 surgical interventions per year on this patient group. MATERIAL AND METHODS A retrospective analysis of closed medical cases performed in the years 2008-2018 at the Northwest Hospital aimed to clarify (1) the frequency of surgical procedures in JW patients associated with a statistical allogeneic transfusion risk (presence of preoperative anemia and/or in-house transfusion probability >10%) during this time period, (2) the degree of acceptance of strategies avoiding blood transfusion by JW and (3) the anemia-related postoperative mortality rate in JW patients. RESULTS In the 11- year observation period 123 surgical procedures with a relevant allogeneic transfusion risk were performed in 105 JW patients. Anemia according to World Health Organization (WHO) criteria was present in 44% of cases on the day of surgery. Synthetic and recombinant drugs (tranexamic acid, desmopressin, erythropoetin, rFVIIa) were generally accepted, acute normovolemic hemodilution (ANH) in 92% and cell salvage in 96%. Coagulation factor concentrates extracted from human plasma and therefore generally refused by JW so far, were accepted by 83% of patients following detailed elucidation. Out of 105 JW patients 7 (6.6%) died during the postoperative hospital stay. In 4 of the 7 fatal cases the cause of death could be traced back to severe postoperative anemia. CONCLUSION Given optimal management JW patients can undergo major surgery without an excessive risk of death. The 6.6% in-hospital mortality observed in this institution was in the range of the 4% generally observed after surgery in Europe. The majority of JW patients accepted a variety of blood conservation strategies following appropriate elucidation. This also included coagulation factor concentrates extracted from human plasma enabling an effective treatment of even severe bleeding complications. In this analysis postoperative hemoglobin concentrations below 6 g/dl in older JW patients were associated with a high mortality risk due to anemia.
Collapse
|