1
|
Knoop RF, Amanzada A, Petzold G, Ellenrieder V, Engelhardt M, Neesse A, Bremer SCB, Kunsch S. Endoscopic mucosal resection and endoscopic submucosal dissection with an external additional working channel (EMR+ and ESD+) are equivalent to using a double-channel endoscope: a systematic evaluation in a porcine ex vivo model. Surg Endosc 2023; 37:7749-7758. [PMID: 37567979 PMCID: PMC10520185 DOI: 10.1007/s00464-023-10295-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2023] [Accepted: 07/02/2023] [Indexed: 08/13/2023]
Abstract
BACKGROUND AND AIMS With an external additional working channel (AWC) endoscopic mucosal resection (EMR) as well as endoscopic submucosal dissection (ESD) can be extended to techniques termed "EMR+" and "ESD+." These novel techniques are systematically compared to EMR and ESD under the use of a double-channel endoscope (DC). METHODS Our trial was conducted prospectively in a pre-clinical porcine animal model (EASIE-R simulator) with standardized gastric lesions measuring 3 or 4 cm. RESULTS EMR+ and EMR DC showed both good results for 3 cm lesions with no adverse events and an en bloc resection rate of 73.33% (EMR+) and 60.00% (EMR DC, p = 0.70). They came to their limits in 4 cm lesions with muscularis damages of 20.00% (EMR+), 13.33% (EMR DC, p ≥ 0.99) and decreasing en bloc resection rates of 60.00% (EMR+) and 46.67% (EMR DC, p = 0.72). ESD+ and ESD DC were both reliable concerning en bloc resection rates (100% in all groups) and adverse events (0.00% in 3 cm lesions, 12.50% muscularis damages in both ESD+ and ESD DC in 4 cm lesions). Resection time was slightly shorter in all groups with the AWC compared to DC although only reaching significance in 3 cm ESD lesions (p < 0.05*). CONCLUSIONS With the AWC, a standard endoscope can easily be transformed to double-channel functionality. We could show that EMR+ and ESD+ are non-inferior to EMR and ESD under the use of a double-channel endoscope. Consequently, the AWC presents an affordable alternative to a double-channel endoscope for both EMR and ESD.
Collapse
Affiliation(s)
- Richard F Knoop
- Department of Gastroenterology, Gastrointestinal Oncology and Endocrinology, University Medical Center Göttingen, Georg-August-University, Göttingen, Germany.
| | - Ahmad Amanzada
- Department of Gastroenterology, Gastrointestinal Oncology and Endocrinology, University Medical Center Göttingen, Georg-August-University, Göttingen, Germany
| | - Golo Petzold
- Department of Gastroenterology, Gastrointestinal Oncology and Endocrinology, University Medical Center Göttingen, Georg-August-University, Göttingen, Germany
| | - Volker Ellenrieder
- Department of Gastroenterology, Gastrointestinal Oncology and Endocrinology, University Medical Center Göttingen, Georg-August-University, Göttingen, Germany
| | - Michael Engelhardt
- Department of Gastroenterology, Internal Medicine and Geriatrics, Rems-Murr-Hospital, Winnenden, Germany
| | - Albrecht Neesse
- Department of Gastroenterology, Gastrointestinal Oncology and Endocrinology, University Medical Center Göttingen, Georg-August-University, Göttingen, Germany
| | - Sebastian C B Bremer
- Department of Gastroenterology, Gastrointestinal Oncology and Endocrinology, University Medical Center Göttingen, Georg-August-University, Göttingen, Germany
| | - Steffen Kunsch
- Department of Gastroenterology, Gastrointestinal Oncology and Endocrinology, University Medical Center Göttingen, Georg-August-University, Göttingen, Germany
- Department of Gastroenterology, Internal Medicine and Geriatrics, Rems-Murr-Hospital, Winnenden, Germany
| |
Collapse
|
2
|
Knoop RF, Wedi E, Petzold G, Bremer SCB, Amanzada A, Ellenrieder V, Neesse A, Kunsch S. Endoscopic submucosal dissection with an additional working channel (ESD+): a novel technique to improve procedure time and safety of ESD. Surg Endosc 2020; 35:3506-3512. [PMID: 32676726 PMCID: PMC8195965 DOI: 10.1007/s00464-020-07808-w] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2020] [Accepted: 07/10/2020] [Indexed: 02/07/2023]
Abstract
Background and aims A new external additional working channel (AWC) was recently introduced by which endoscopic submucosal dissection (ESD) can be converted to a technique termed “ESD+ ”. We aim to systematically evaluate this novel technique in flat gastric lesions and compare it to classical ESD. Methods The study was prospectively conducted in a pre-clinical ex vivo animal model (EASIE-R simulator) with porcine stomachs. Prior to intervention, we set standardized lesions measuring 3 cm or 4 cm in antegrade as well as in retrograde positions. Results Overall, 64 procedures were performed by an experienced endoscopist. Both techniques were reliable and showed en bloc resection rates of 100%. Overall, ESD+ reduced time of procedure compared to ESD (24.5 vs. 32.5 min, p = 0.025*). Particularly, ESD+ was significantly faster in retrograde lesions with a median of 22.5 vs. 34.0 min in 3 cm retrograde lesions (p = 0.002*) and 34.5 vs. 41.0 min (p = 0.011*) in 4 cm retrograde lesions. There were 0 perforations with both techniques. In ESD+ , 1 muscularis damage occurred (3.13%) compared to 6 muscularis damages with ESD (18.75%, p = 0.045*). Conclusions By its grasp-and-mobilize technique, ESD+ allows potentially faster and safer resections of flat gastric lesions compared to conventional ESD in an ex vivo porcine model. The potential advantages of ESD+ in terms of procedure time may be particularly relevant for difficult lesions in retrograde positions. Electronic supplementary material The online version of this article (10.1007/s00464-020-07808-w) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Richard F Knoop
- Department of Gastroenterology and Gastrointestinal Oncology, University Medical Center Goettingen, Georg-August-University, 37075, Göttingen, Germany
| | - Edris Wedi
- Department of Gastroenterology and Gastrointestinal Oncology, University Medical Center Goettingen, Georg-August-University, 37075, Göttingen, Germany
| | - Golo Petzold
- Department of Gastroenterology and Gastrointestinal Oncology, University Medical Center Goettingen, Georg-August-University, 37075, Göttingen, Germany
| | - Sebastian C B Bremer
- Department of Gastroenterology and Gastrointestinal Oncology, University Medical Center Goettingen, Georg-August-University, 37075, Göttingen, Germany
| | - Ahmad Amanzada
- Department of Gastroenterology and Gastrointestinal Oncology, University Medical Center Goettingen, Georg-August-University, 37075, Göttingen, Germany
| | - Volker Ellenrieder
- Department of Gastroenterology and Gastrointestinal Oncology, University Medical Center Goettingen, Georg-August-University, 37075, Göttingen, Germany
| | - Albrecht Neesse
- Department of Gastroenterology and Gastrointestinal Oncology, University Medical Center Goettingen, Georg-August-University, 37075, Göttingen, Germany
| | - Steffen Kunsch
- Department of Gastroenterology and Gastrointestinal Oncology, University Medical Center Goettingen, Georg-August-University, 37075, Göttingen, Germany.
| |
Collapse
|
3
|
Sportes A, Cfm J, Gromski MA, Koehler P, Seif Amir Hosseini A, Kauffmann P, Ellenrieder V, Wedi E. Novel modified endoscopic mucosal resection of large GI lesions (> 20 mm) using an external additional working channel (AWC) may improve R0 resection rate: initial clinical experience. BMC Gastroenterol 2020; 20:195. [PMID: 32560696 PMCID: PMC7304141 DOI: 10.1186/s12876-020-01344-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/22/2019] [Accepted: 06/11/2020] [Indexed: 02/07/2023] Open
Abstract
Background En-bloc resection of large, flat dysplastic mucosal lesions of the luminal GI tract can be challenging. In order to improve the efficacy of resection for lesions ≥2 cm and to optimize R0 resection rates of lesions suspected of harboring high-grade dysplasia or early adenocarcinoma, a novel grasp and snare EMR technique utilizing a novel over the scope additional accessory channel, termed EMR Plus (EMR+), was developed. The aim of this pilot study is to describe the early safety and efficacy data from the first in human clinical cases. Methods A novel external over-the-scope additional working channel (AWC) (Ovesco, Tuebingen, Germany) was utilized for the EMR+ procedure, allowing a second endoscopic device to be used through the AWC while using otherwise standard endoscopic equipment. The EMR+ technique allows tissue retraction and a degree of triangulation during endoscopic resection. We performed EMR+ procedure in 6 patients between 02/2018–12/2018 for lesions in the upper and lower GI tract. Results The EMR+ technique utilizing the AWC was performed successfully in 6 resection procedures of the upper and/or lower GI tract in 6 patients in 2 endoscopy centers. All resections were performed successfully with the EMR+ technique, all achieving an R0 resection. No severe adverse events occurred in any of the procedures. Conclusions The EMR+ technique, utilizing an additional working channel, had an acceptable safety and efficacy profile in this preliminary study demonstrating it’s first use in humans. This technique may allow an additional option to providers to remove complex, large mucosal-based lesions in the GI tract using standard endoscopic equipment and a novel AWC device.
Collapse
Affiliation(s)
- A Sportes
- Department of Gastroenterology, Institut Arnault Tzanck, Saint Laurent du Var, France
| | - Jung Cfm
- Department of Gastroenterology and Gastrointestinal Oncology, Interdisciplinary Endoscopy, University Medical Center, Georg-August-University, 37075, Goettingen, Germany
| | - M A Gromski
- Division of Gastroenterology and Hepatology, Indiana University School of Medicine, Indianapolis, IN, USA
| | - P Koehler
- Institute of Farm Animal Genetics, Friedrich-Loeffler-Institut (FLI), Federal Research Institute for Animal Health, Mariensee, Germany
| | - A Seif Amir Hosseini
- Department of Diagnostic and Interventional Radiology, University Medical Center, Göttingen, Germany
| | - P Kauffmann
- Department of Oral and Maxillofacial Surgery, University Medical Center Goettingen, Göttingen, Germany
| | - V Ellenrieder
- Department of Gastroenterology and Gastrointestinal Oncology, Interdisciplinary Endoscopy, University Medical Center, Georg-August-University, 37075, Goettingen, Germany
| | - E Wedi
- Department of Gastroenterology and Gastrointestinal Oncology, Interdisciplinary Endoscopy, University Medical Center, Georg-August-University, 37075, Goettingen, Germany.
| |
Collapse
|
4
|
Wedi E, Knoop R, Jung C, Gromski M, Ho CN, Conrad G, Maiss J, Milenovic S, Klemme D, Baulain U, Seif Amir Hosseini A, Ellenrieder V, Koehler P. EMR + with the AWC improves endoscopic resection speed compared to ESD: a porcine ex-vivo pilot study. MINIM INVASIV THER 2019; 30:47-54. [PMID: 31597491 DOI: 10.1080/13645706.2019.1673778] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
INTRODUCTION To improve resection speed and to reach higher en bloc resection rates in lesions ≥ 2 cm, a novel grasp and snare EMR technique termed "EMR+", accomplished by an additional working channel (AWC), was developed. Its use compared to endoscopic submucosal dissection (ESD) is evaluated for the first time. MATERIAL AND METHODS We prospectively conducted a randomized pre-clinical ex-vivo pilot study in explanted porcine stomachs for the comparison of EMR + with classical ESD of mucosal-based lesions. Prior to intervention, we set flat lesions with a standardized size of 3 × 3 cm. RESULTS The median time of procedure was significantly shorter in the EMR + group (median 10.5 min, range 4.4-24 min) than in the ESD group (median 32 min, range 14-61.6 min, p < .0001). The rate of en bloc resection was significantly lower in the EMR + group (38 % vs. 95 %) (p < .0001). Nevertheless, an improvement in the learning curve for EMR + was achieved after the first 12 procedures, with a subsequent en bloc resection rate of 100 %. CONCLUSIONS EMR + could improve the efficiency of mucosal resection procedures. Initial experience demonstrates a higher and satisfactory en bloc resection rate after going through the learning curve of EMR+.
Collapse
Affiliation(s)
- Edris Wedi
- Department of Gastroenterology and Gastrointestinal Oncology, Interdisciplinary Endoscopy, University Medical Center, Goettingen, Germany
| | - Richard Knoop
- Department of Gastroenterology and Gastrointestinal Oncology, Interdisciplinary Endoscopy, University Medical Center, Goettingen, Germany
| | - Carlo Jung
- Department of Gastroenterology and Gastrointestinal Oncology, Interdisciplinary Endoscopy, University Medical Center, Goettingen, Germany
| | - Mark Gromski
- Division of Gastroenterology and Hepatology, Indiana University School of Medicine, Indianapolis, USA
| | | | | | - Juergen Maiss
- Department of Gastroenterology, Associate Prof. Maiss, Forchheim, Germany
| | - Sinisa Milenovic
- Department of Gastroenterology and Gastrointestinal Oncology, Interdisciplinary Endoscopy, University Medical Center, Goettingen, Germany
| | - David Klemme
- Department of Gastroenterology and Gastrointestinal Oncology, Interdisciplinary Endoscopy, University Medical Center, Goettingen, Germany
| | - Ulrich Baulain
- Institute of Farm Animal Genetics, Friedrich-Loeffler-Institut (FLI), Federal Research Institute for Animal Health, Mariensee, Germany
| | - Ali Seif Amir Hosseini
- Department of Diagnostic and Interventional Radiology, University Medical Center, Goettingen, Germany
| | - Volker Ellenrieder
- Department of Gastroenterology and Gastrointestinal Oncology, Interdisciplinary Endoscopy, University Medical Center, Goettingen, Germany
| | - Peter Koehler
- Institute of Farm Animal Genetics, Friedrich-Loeffler-Institut (FLI), Federal Research Institute for Animal Health, Mariensee, Germany
| |
Collapse
|
5
|
Wedi E, Koehler P, Hochberger J, Maiss J, Milenovic S, Gromski M, Ho N, Gabor C, Baulain U, Ellenrieder V, Jung C. Endoscopic submucosal dissection with a novel high viscosity injection solution (LiftUp) in an ex vivo model: a prospective randomized study. Endosc Int Open 2019; 7:E641-E646. [PMID: 31058206 PMCID: PMC6497499 DOI: 10.1055/a-0874-1844] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/05/2018] [Accepted: 11/02/2018] [Indexed: 02/08/2023] Open
Abstract
Introduction Endoscopic submucosal dissection (ESD) is increasingly being used in the western world. Submucosal injectates are an essential tool for the ESD procedure. In this study, we evaluated a novel copolymer injectate (LiftUp, Ovesco, Tübingen Germany) in an established ESD model (EASIE-R) in comparison to existing submucosal injectables. Materials and methods We conducted a prospective, randomized ex vivo study performing ESD with three injectates: LiftUp, hydroxyethyl starch (HAES 6 %) and normal saline solution (NaCl 0.9 %). A total of 60 artificial lesions, each 3 × 3 cm in size, were resected in an ex vivo porcine model, utilizing one of the three studied injectates (n = 20 ESDs per injectate). Study parameters were: en bloc resection rate, perforation rate, lifting property, time of injection, injectate volume, general ESD procedure time, and overall procedure time. Results All 60 lesions were successfully resected using the standard ESD technique. LiftUp had no procedure related perforations, one perforation occurred in the HAES group, and two perforations in the NaCl group ( P > 0.05). Furthermore, adequate lifting was achieved in 16/20 (80 %) using LiftUp, 6/20 (30 %) in the HAES group and 6/20 (30 %) in the NaCl group ( P < 0.0002). En bloc resection was achieved in 19 (95 %) with LiftUp, in 20 (100 %) with HAES, and in 16 (80 %) with NaCl. General ESD procedure time and overall procedure time were not different among the three groups. Conclusion LiftUp appears to be a safe alternative to established fluids for ESD. It had a significantly improved lifting effect and required significantly less injected volume compared to well-established lifting solutions.
Collapse
Affiliation(s)
- E. Wedi
- Department of Gastroenterology and Gastrointestinal Oncology, Center of Interdisciplinary Endoscopy, University Medical Centre Göttingen, Göttingen, Germany
| | - P. Koehler
- Institute of Farm Animal Genetics, Friedrich-Loeffler-Institut (FLI), Federal Research Institute for Animal Health, Mariensee, Germany
| | - J. Hochberger
- Department of Gastroenterology, Vivantes Klinikum in Friedrichshain, Teaching Hospital of Charité Humboldt University, Berlin, Germany
| | - J. Maiss
- Department of Gastroenterology, Associates Dr. Kerzel and Prof. Maiss, Forchheim, Germany
| | - S. Milenovic
- Department of Gastroenterology and Gastrointestinal Oncology, Center of Interdisciplinary Endoscopy, University Medical Centre Göttingen, Göttingen, Germany
| | - M. Gromski
- Division of Gastroenterology and Hepatology, Indiana University School of Medicine, Indianapolis, IN, USA
| | - N. Ho
- Ovesco Endoscopy AG, Tübingen, Germany
| | - C. Gabor
- Ovesco Endoscopy AG, Tübingen, Germany
| | - U. Baulain
- Institute of Farm Animal Genetics, Friedrich-Loeffler-Institut (FLI), Federal Research Institute for Animal Health, Mariensee, Germany
| | - V. Ellenrieder
- Department of Gastroenterology and Gastrointestinal Oncology, Center of Interdisciplinary Endoscopy, University Medical Centre Göttingen, Göttingen, Germany
| | - C. Jung
- Department of Gastroenterology and Gastrointestinal Oncology, Center of Interdisciplinary Endoscopy, University Medical Centre Göttingen, Göttingen, Germany
| |
Collapse
|
6
|
Knoop RF, Schmidt A, Kayser G, Thimme R, Fischer A. Endoscopic submucosal dissection of an esophageal granular cell tumor. VideoGIE 2019; 4:58-61. [PMID: 30766943 PMCID: PMC6363592 DOI: 10.1016/j.vgie.2018.10.015] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/28/2022] Open
Affiliation(s)
- Richard F Knoop
- Department of Gastroenterology and Gastrointestinal Oncology, University Medical Center Goettingen, University of Goettingen, Goettingen, Germany
| | - Arthur Schmidt
- Faculty of Medicine, Department of Medicine II, University Hospital Freiburg, University of Freiburg, Freiburg, Germany
| | - Gian Kayser
- Faculty of Medicine, Institute for Surgical Pathology, University Hospital Freiburg, University of Freiburg, Freiburg, Germany
| | - Robert Thimme
- Faculty of Medicine, Department of Medicine II, University Hospital Freiburg, University of Freiburg, Freiburg, Germany
| | - Andreas Fischer
- Faculty of Medicine, Department of Medicine II, University Hospital Freiburg, University of Freiburg, Freiburg, Germany
| |
Collapse
|
7
|
Sullivan JF, Dumot JA. Maximizing the Effectiveness of Colonoscopy in the Prevention of Colorectal Cancer. Surg Oncol Clin N Am 2018; 27:367-376. [PMID: 29496095 DOI: 10.1016/j.soc.2017.11.009] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Affiliation(s)
- John F Sullivan
- Department of Gastroenterology and Liver Disease, University Hospitals Cleveland Medical Center, 11100 Euclid Avenue, Cleveland, OH 44106, USA
| | - John A Dumot
- Digestive Health Institute, University Hospitals Cleveland Medical Center, 11100 Euclid Avenue, Cleveland, OH 44106, USA.
| |
Collapse
|
8
|
Wedi E, Orlandini B, Gromski M, Jung CFM, Tchoumak I, Boucher S, Ellenrieder V, Hochberger J. Full-Thickness Resection Device for Complex Colorectal Lesions in High-Risk Patients as a Last-Resort Endoscopic Treatment: Initial Clinical Experience and Review of the Current Literature. Clin Endosc 2018; 51:103-108. [PMID: 29397654 PMCID: PMC5806922 DOI: 10.5946/ce.2017.093] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/07/2017] [Revised: 09/27/2017] [Accepted: 10/20/2017] [Indexed: 12/19/2022] Open
Abstract
The full-thickness resection device (FTRD) is a novel endoscopic device approved for the resection of colorectal lesions. This case-series describes the device and its use in high-risk patients with colorectal lesions and provides an overview of the potential indications in recently published data.
Between December 2014 and September 2015, 3 patients underwent endoscopic full thickness resection using the FTRD for colorectal lesions: 1 case for a T1 adenocarcinoma in the region of a surgical anastomosis after recto-sigmoidectomy, 1 case for a non-lifting colonic adenoma with low-grade dysplasia in an 89-year old patient and 1 for a recurrent adenoma with high-grade dysplasia in a young patient with ulcerative rectocolitis who was under immunosuppression after renal transplantation. Both technical and clinical success rates were achieved in all cases. The size of removed lesions ranged from 9 to 30 mm. Overall, the most frequent indication in the literature has been for lifting or non-lifting adenoma, submucosal tumors, neuroendocrin tumors, incomplete endoscopic resection (R1) or T1 carcinoma. Colorectal FTRD is a feasible technique for the treatment of colorectal lesions and represents a minimally invasive alternative for either surgical or conventional endoscopic resection strategies.
Collapse
Affiliation(s)
- Edris Wedi
- Department of Gastroenterology and Gastrointestinal Oncology, University Medical Center Göttingen, Göttingen, Germany
| | - Beatrice Orlandini
- Department of Gastroenterology, Careggi University Hospital, Florence, Italy
| | - Mark Gromski
- Division of Gastroenterology, Indiana University School of Medicine, Indianapolis, IN, USA
| | - Carlo Felix Maria Jung
- Department of Gastroenterology and Gastrointestinal Oncology, University Medical Center Göttingen, Göttingen, Germany
| | - Irina Tchoumak
- Department of Gastroenterology and Gastrointestinal Oncology, University Medical Center Göttingen, Göttingen, Germany
| | - Stephanie Boucher
- Department of Pathology, Nouvel Hôpital Civil, Strasbourg University Hospitals, Strasbourg, France
| | - Volker Ellenrieder
- Department of Gastroenterology and Gastrointestinal Oncology, University Medical Center Göttingen, Göttingen, Germany
| | - Jürgen Hochberger
- 5Department of Internal Medicine, Vivantes Klinikum im Friedrichshain, University Teaching Hospital of Humboldt University Berlin (Charité), Berlin, Germany
| |
Collapse
|
9
|
Magnifying endoscopy with narrow band imaging to determine the extent of resection in transoral robotic surgery of oropharyngeal cancer. Case Rep Otolaryngol 2014; 2014:604737. [PMID: 25574412 PMCID: PMC4276113 DOI: 10.1155/2014/604737] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2014] [Accepted: 11/26/2014] [Indexed: 01/13/2023] Open
Abstract
Transoral robotic surgery (TORS) is a less invasive treatment that is becoming popular all over the world. One of the most important factors for achieving success in TORS is the ability to determine the extent of resection during the procedure as the extent of resection in the laryngopharynx not only affects oncological outcomes but also directly affects swallowing and voice functions. Magnifying endoscopy with narrow band imaging (ME-NBI) is an innovative optical technology that provides high-resolution images and is useful in detecting early superficial pharyngeal cancers, which are difficult to detect by standard endoscopy. A 55-year-old male with superficial oropharyngeal cancer has been successfully treated by combining MB-NBI with TORS and MB-NBI was useful in determining the extent of resection. ME-NBI with TORS will make it possible to achieve a higher ratio of minimally invasive treatment in pharyngeal cancer.
Collapse
|