1
|
Ciric D, Mischler D, Qawasmi F, Wenzel L, Richards RG, Gueorguiev B, Windolf M, Varga P. Secondary Perforation Risk in Plate Osteosynthesis of Unstable Proximal Humerus Fractures: A Biomechanical Investigation of the Effect of Screw Length. J Orthop Res 2019; 37:2625-2633. [PMID: 31350928 DOI: 10.1002/jor.24429] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/10/2019] [Accepted: 07/24/2019] [Indexed: 02/04/2023]
Abstract
Secondary perforation of screws into the joint surface is a commonly reported mechanical fixation failure mode in locked plating of proximal humerus fractures (PHF). This study investigated the influence that screws tip to joint distance (TJD) has on the biomechanical risk of secondary screw perforation and the stability of PHF. Ten pairs of cadaveric proximal humeri with a wide range of bone mineral density were used. Each specimen was osteotomized and instrumented with the PHILOS plate, simulating a highly unstable 3-part fracture. Bones were randomized into a long screw group (LSG) with 4 mm TJD, or a short screw group (SSG) with 8 mm TJD. A custom biomechanical setup was used to test the samples to failure cyclically with a constant valley load and an increasing ramp. The number of cycles to the initial screw loosening event was significantly higher for the LSG (mean ± standard deviation: 17,532 ± 6,458) compared with the SSG (11,102 ± 5,440) (p < 0.01). The mode of failure during testing was lateral-inferior displacement combined with varus collapse, with calcar screws perforating first. The number of cycles to failure event for LSG (27,849 ± 5,648) was not significantly different compared with SSG (28,782 ± 7,307) (p = 0.50). Screws that purchase closer to the joint had better initial stability and resistance against loosening. Placing longer screws, within limits dictated by the surgical guide, is expected to decrease the risk of secondary perforation failures in unstable PHF. These findings require clinical corroboration. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 37:2625-2633, 2019.
Collapse
Affiliation(s)
- Daniel Ciric
- AO Research Institute Davos, Davos, Switzerland.,College of Science and Engineering, Flinders University, Tonesly, South Australia
| | | | - Feras Qawasmi
- AO Research Institute Davos, Davos, Switzerland.,Hadassah Medical Centre, Jerusalem, Israel
| | - Lisa Wenzel
- AO Research Institute Davos, Davos, Switzerland.,Department of Trauma Surgery, Trauma Center Murnau, Murnau, Germany
| | | | | | | | - Peter Varga
- AO Research Institute Davos, Davos, Switzerland
| |
Collapse
|
2
|
Bockmann B, Buecking B, Franz D, Zettl R, Ruchholtz S, Mohr J. Mid-term results of a less-invasive locking plate fixation method for proximal humeral fractures: a prospective observational study. BMC Musculoskelet Disord 2015; 16:160. [PMID: 26141352 PMCID: PMC4491200 DOI: 10.1186/s12891-015-0618-y] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/16/2015] [Accepted: 06/24/2015] [Indexed: 12/02/2022] Open
Abstract
Background The optimal treatment for proximal humeral fractures remains under debate. In this article, we report the mid-term results of patients who underwent the less-invasive implantation of a polyaxial locking plate for displaced proximal humeral fractures. Methods This study included patients who were treated with a polyaxial locking plate via an anterolateral deltoid split approach from May 2008 to December 2011. We evaluated outcome parameters after a minimum follow-up period of 2.5 years (median 4.5 years, follow-up rate 62 %) including the age- and gender-dependent Constant score, the activities of daily living score, and the visual analog scale for both pain and subjective shoulder function. Results Of the 140 patients who underwent surgery, 114 were included in the follow-up and 71 completed the questionnaire. Fifteen patients (21 %) exhibited 2-fragment fractures, and 56 patients (79 %) exhibited 3- and 4-part fractures. The Constant score improved significantly (4.5 years: 70 ± 21, p < 0.001) between the first two follow-ups (6 weeks: 35 ± 14, 6 months: 56 ± 18, p < 0.001), and also between 6 months and 4.5 years post-surgery. At the final follow-up, the activities of daily living score had not reached pre-fracture levels (before trauma: 27 ± 5, 4.5 years: 20 ± 8, p < 0.001). A multivariate analysis showed that age has a more significant influence on the final outcome than fracture morphology or gender. Conclusion Although the less-invasive surgical procedure is a feasible treatment option in proximal humeral fractures with acceptable complications and considerable improvement during the first six months, a lengthy recovery time is required. The majority of our patients did not become pain-free or reach pre-fracture activity levels.
Collapse
Affiliation(s)
- Benjamin Bockmann
- Center for Orthopedics and Trauma Surgery, University Hospital Giessen and Marburg, Location Marburg, Baldingerstrasse, 35043, Marburg, Germany.
| | - Benjamin Buecking
- Center for Orthopedics and Trauma Surgery, University Hospital Giessen and Marburg, Location Marburg, Baldingerstrasse, 35043, Marburg, Germany.
| | - Daniel Franz
- Center for Orthopedics and Trauma Surgery, University Hospital Giessen and Marburg, Location Marburg, Baldingerstrasse, 35043, Marburg, Germany.
| | - Ralph Zettl
- Center for Orthopedics and Trauma Surgery, University Hospital Giessen and Marburg, Location Marburg, Baldingerstrasse, 35043, Marburg, Germany.
| | - Steffen Ruchholtz
- Center for Orthopedics and Trauma Surgery, University Hospital Giessen and Marburg, Location Marburg, Baldingerstrasse, 35043, Marburg, Germany.
| | - Juliane Mohr
- Department of Trauma Surgery, Otto-von-Guericke University, Leipziger Strasse 44, 39120, Magdeburg, Germany.
| |
Collapse
|
3
|
El-Zayat BF, Efe T, Ruchholtz S, Khatib S, Timmesfeld N, Krüger A, Zettl R. Mono- versus polyaxial locking plates in distal femur fractures - a biomechanical comparison of the Non-Contact-Bridging- (NCB) and the PERILOC-plate. BMC Musculoskelet Disord 2014; 15:369. [PMID: 25373872 PMCID: PMC4232626 DOI: 10.1186/1471-2474-15-369] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/07/2014] [Accepted: 10/27/2014] [Indexed: 12/01/2022] Open
Abstract
Background The aim of this cadaveric study was to compare a polyaxial (NCB®, Zimmer) to a fixed-angle monoaxial locking plate (PERILOC®, Smith & Nephew) in comminuted fractures of the distal femur regarding stability of the construct. Up to date there is no published biomechanical data concerning polyaxial plating in cadaveric distal femurs. Methods Fourteen formalin fixed femora were scanned by dual-energy x-ray absorptiometry. As fracture model an unstable supracondylar comminuted fracture was simulated. Fractures were pairwise randomly fixed either with a mono- (group A) or a polyaxial (group B) distal femur plate. The samples were tested in a servohydraulic mechanical testing system starting with an axial loading of 200 N following an increase of 200 N in every step with 500 cycles in every sequence up to a maximum of 2 000 N. The end points were implant failure or relevant loss of reduction. Data records included for each specimen time, number of cycles, axial load and axial displacement. Statistical analysis was performed using the exact Wilcoxon signed rank test. Results The mean donor age at the time of death was 75 years. The bone mass density (BMD) of the femurs in both groups was comparable and showed no statistically significant differences. Five bones failed before reaching the maximum applied force of 2000 N. Distribution curves of all samples in both groups, showing the plastic deformation in relation to the axial force, showed no statistically significant differences. Conclusions Operative stabilization of distal femur fractures can be successfully and equally well achieved using either a monoaxial or a polyaxial locking plate. Polyaxial screw fixation may have advantages if intramedullary implants are present. Electronic supplementary material The online version of this article (doi:10.1186/1471-2474-15-369) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Bilal Farouk El-Zayat
- Department of Orthopaedics and Rheumatology, University Hospital Marburg, Baldingerstrasse, 35043 Marburg, Germany.
| | | | | | | | | | | | | |
Collapse
|
4
|
Minimally invasive polyaxial locking plate fixation of proximal humeral fractures: a prospective study. ACTA ACUST UNITED AC 2012; 71:1737-44. [PMID: 22182882 DOI: 10.1097/ta.0b013e31823f62e4] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
BACKGROUND The surgical treatment for displaced humeral head fractures overlooks a broad variety of surgical techniques and implant systems. A standard operative procedure has not yet been established. In this article, we report our experience with a second-generation locking plate for the humeral head fracture that is applied in a standardized nine-step minimally invasive surgical technique (MIS). METHODS In a prospective study from May 2008 until November 2009, a cohort of 79 patients with 80 proximal humerus fractures were operated in a MIS procedure using a polyaxial locking plate. Follow-up examination at 6 weeks and 6 months postoperative included radiologic examinations and a clinical outcome analysis by the Constant Score, the Visual Analog Scale for pain, and the Daily Activity Score. RESULTS The mean patient age was 65.5 years ± 19 years. According to the Neer classification, there were 18 (22.5%) two-part (Neer III), 48 (60%) three-part (Neer IV), and 14 (17.5%) four-part fractures (Neer IV/V). The operation time averaged 65.6 minutes ± 27 minutes. In 13 patients (16.3%), revision was necessary because of procedure-related complications. After 6 months, the Visual Analog Scale for pain was 2.7 ± 1.6 and the Daily Activity Score showed 19.6 ± 6 points. The average age-related Constant Score after 6 months was 67.5 ± 24 points. CONCLUSIONS MIS surgery of displaced humeral head fractures can be performed in all types of humeral head fractures leading to low complication rates and good clinical outcome. A standardized stepwise procedure in fracture reduction and fixation is recommended to achieve reliable good results.
Collapse
|
5
|
Brorson S, Frich LH, Winther A, Hróbjartsson A. Locking plate osteosynthesis in displaced 4-part fractures of the proximal humerus. Acta Orthop 2011; 82:475-81. [PMID: 21657970 PMCID: PMC3237040 DOI: 10.3109/17453674.2011.588856] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/13/2010] [Accepted: 03/08/2011] [Indexed: 01/31/2023] Open
Abstract
BACKGROUND AND PURPOSE There is considerable uncertainty about the optimal treatment of displaced 4-part fractures of the proximal humerus. Within the last decade, locking plate technology has been considered a breakthrough in the treatment of these complex injuries. METHODS We systematically identified and reviewed clinical studies on the benefits and harms after osteosynthesis with locking plates in displaced 4-part fractures. RESULTS We included 14 studies with 374 four-part fractures. There were 10 case series, 3 retrospective observational comparative studies, 1 prospective observational comparative study, and no randomized trials. Small studies with a high risk of bias precluded reliable estimates of functional outcome. High rates of complications (16-64%) and reoperations (11-27%) were reported. INTERPRETATION The empirical foundation for the value of locking plates in displaced 4-part fractures of the proximal humerus is weak. We emphasize the need for well-conducted randomized trials and observational studies.
Collapse
Affiliation(s)
- Stig Brorson
- Department of Orthopaedic Surgery, Herlev University Hospital, Herlev, Denmark.
| | | | | | | |
Collapse
|
6
|
Röderer G, Sperfeld AD, Hansen P, Krischak G, Gebhard F, Kassubek J. Electrophysiological assessment of the deltoid muscle after minimally invasive treatment of proximal humerus fractures - a clinical observation. Open Orthop J 2011; 5:223-8. [PMID: 21760869 PMCID: PMC3134951 DOI: 10.2174/1874325001105010223] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/28/2011] [Revised: 05/02/2011] [Accepted: 05/11/2011] [Indexed: 11/22/2022] Open
Abstract
The minimal anterolateral acromial approach offers a less invasive access to the proximal humerus. Functional impairment following this procedure may be caused by paresis of the deltoid muscle as a result of iatrogenic injury to the axillary nerve. It was addressed whether electromyography (EMG) of the deltoid muscle gives evidence for an axillary nerve lesion in association with the minimal anterolateral acromial approach. Twenty-three patients (14 men, 9 women; average age 58 years) with proximal humerus fractures were included in this clinical observation. Follow-up was performed 6 weeks (6w), 6 months (6m) and 12 months (12m) postoperatively. EMG changes indicating either lesion of the axillary nerve or direct muscle trauma were distinguished in “acute”, “chronic” and “combined” and semi quantified in “slight”, “moderate” and “severe”. Patients were examined clinically (standard neurological examination and Constant Score). Three cases of incomplete axillary nerve lesion with limited functional impairment were detected. Subclinical EMG signs of neural impairment of the deltoid muscle were observed frequently (6w, N = 8; 6m, N = 8; 12m, N = 7). Functional outcome did not show an association with EMG. Most patients presented with subclinical and most likely trauma- related neurogenic lesions of the deltoid muscle following the anterolateral acromial approach. Despite the fact that the axillary nerve does not function normally following this less-invasive approach for fixation of proximal humerus fractures, this does not appear to affect the clinical outcome. Prospective studies with larger sample sizes are required to determine the effect of axillary nerve retraction in the more commonly used deltopectoral approach.
Collapse
Affiliation(s)
- Götz Röderer
- University of Ulm, Department of Orthopaedic Trauma, Steinhövelstraße 9, D-89075 Ulm, Germany
| | | | | | | | | | | |
Collapse
|
7
|
Zettl R, Müller T, Topp T, Lewan U, Krüger A, Kühne C, Ruchholtz S. Monoaxial versus polyaxial locking systems: a biomechanical analysis of different locking systems for the fixation of proximal humeral fractures. INTERNATIONAL ORTHOPAEDICS 2011; 35:1245-50. [PMID: 21301828 DOI: 10.1007/s00264-011-1220-z] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/20/2010] [Accepted: 01/18/2011] [Indexed: 11/25/2022]
Abstract
OBJECTIVE The development of locking plate systems has led to polyaxial screws and new plate designs. This study compares monoaxial head locking screws (PHILOS© by Synthes) and a new generation of polyaxial locking screws (NCB-LE© by Zimmer) with respect to biomechanical stability. METHODS On nine pairs of randomised formalin fixed humerus specimens, standardised osteotomies and osteosyntheses with nine monoaxial (group A) und nine polyaxial (group B) plate/screw systems were performed. A material testing machine by Instron (M-10 14961-DE) was used for cyclic stress tests and crash tests until defined breakup criteria as endpoints were reached. RESULTS After axial cyclic stress 200 times at 90 N, plastic deformation was 1.02 mm in group A and 1.25 mm in group B. After the next cycle using 180 N the additional deformation averaged 0.23 mm in group A and 0.39 mm in group B. The deformation using 450 N was 0.72 mm in group A compared to 0.92 mm in group B. The final full power test resulted in a deformation average of 0.49 mm in group A and 0.63 mm in group B after 2,000 cycles using 450 N. When reaching the breakup criteria the plastic deformation of the NCB plate was 9.04 mm on average. The PHILOS plate was similarly deformed by 9.00 mm. As a result of the crash test, in group A the screws pulled out of the humeral head four times whereas the shaft broke one time and another time the implant was ripped out. The gap was closed four times. In group B, there were three cases of screw cut-through, four shaft fractures/screw avulsions from the shaft and two cases of gap closure. CONCLUSION The two systems resist the cyclic duration tests and the increasing force tests in a similar manner. The considerable clinical benefits of the polyaxial system are enhanced by equal biomechanical performance.
Collapse
Affiliation(s)
- Ralph Zettl
- Department of Trauma-, Hand- and Reconstructive Surgery, University Hospital Giessen and Marburg GmbH, Baldingerstraße, 35041 Marburg, Germany.
| | | | | | | | | | | | | |
Collapse
|
8
|
[Biomechanical investigation of fixed-angle plate osteosynthesis of the proximal humerus]. Unfallchirurg 2010; 113:133-8. [PMID: 20024525 DOI: 10.1007/s00113-009-1672-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
INTRODUCTION Proximal humeral fractures are common in the elderly population and are often associated with osteoporosis. Fixation of unstable proximal humeral fractures is problematic due to loss of fixation in osteoporotic bone. Fixed-angle devices are intended to provide superior mechanical stability due to the principle of an internal fixator. The NCB(R)-PH (non-contact-bridging proximal humerus) plate is a new fixed-angle device that locks the screws to the plate by secondary insertion of a locking cap. The aim of this study was to investigate if and to what extent NCB-PH plates applied in the locked mode provide higher mechanical stability in a proximal humerus fracture model. METHODS For this investigation 16 (8 pairs) fresh frozen cadaveric humeri were used. An AO/ASIF 11-B 1 fracture of the proximal humerus was created in each bone and fixed with the NCB-PH plate. In a paired setting one bone was fixed with the plate in the locked mode and the other with the plate in the non-locked mode. The bones were then subjected to 100 cycles of axial loading and interfragmentary motion was measured. Bones surviving this test were subjected to load-to-failure testing and the force at which failure occurred was recorded. RESULTS Bones fixed with the plate in the locked mode showed a statistically significant lower (51%) interfragmentary rotation compared to bones fixed with the plate in the non-locked mode. There was also a tendency for the bones fixed with the plate in the locked mode to fail first under higher forces (16%) during load-to-failure testing. CONCLUSION The NCB-PH plate provides superior interfragmentary stability when used in the locked mode in a human cadaveric proximal humerus fracture model. Therefore, we recommend that all screws should be inserted in the locked mode. The results suggest that the NCB-PH plate in the locked mode provides higher primary postoperative stability thus permitting early functional treatment of the patient.
Collapse
|
9
|
Biomechanical in vitro assessment of fixed angle plating using a new concept of locking for the treatment of osteoporotic proximal humerus fractures. INTERNATIONAL ORTHOPAEDICS 2010; 35:535-41. [PMID: 20419451 DOI: 10.1007/s00264-010-1021-9] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/17/2010] [Revised: 04/01/2010] [Accepted: 04/02/2010] [Indexed: 10/19/2022]
Abstract
Locked plating attempts to improve mechanical stability via better anchorage of the screws in the bone. In 22 paired osteoporotic humeri an AO/ASIF 11-B 1 fracture was created. Locked and conventional plating using the same device of the latest generation was performed. Torsional loading around three axes (x = varus/valgus, y = flexion/extension, z = axial rotation) with an increasing moment (2, 3.5, 5 and 7.5 N·m) was applied. Interfragmentary motion within the locked group was lower for all three axes with higher cumulative survival rates (p < 0.05). The typical mode of failure was loss of fixation in the humeral head occurring earlier in the conventional group. The locking mechanism investigated provides more ultimate strength in an osteoporotic proximal humerus fracture model. Correlation with BMD suggests that this device may especially be suitable for use in osteoporotic bone.
Collapse
|
10
|
Second generation locked plating of proximal humerus fractures--a prospective multicentre observational study. INTERNATIONAL ORTHOPAEDICS 2010; 35:425-32. [PMID: 20419453 DOI: 10.1007/s00264-010-1015-7] [Citation(s) in RCA: 53] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/04/2010] [Revised: 03/24/2010] [Accepted: 03/28/2010] [Indexed: 10/19/2022]
Abstract
Surgical treatment of most displaced proximal humerus fractures is challenging due to osteoporosis. Locking plates are intended to provide superior mechanical stability. In a prospective multicentre study 131 patients were treated with second generation locked plating (NCB-PH, Zimmer, Inc.). The open procedure (n = 78) was performed using a deltopectoral approach; the minimally invasive technique (n = 53) involved percutaneous reduction and an anterolateral deltoid split approach. Clinical and radiological follow-up was obtained. Improvement in function (ROM) was statistically significant. Fracture type (AO) had the most significant impact on the incidence of complications. The most frequent complications detected were intra-articular screw perforation (15%) and secondary displacement (8%). Complication rate and functional outcome of the NCB-PH are comparable to reports in the literature. Not all problems are likely to be solved by this new generation of implants, i.e. secondary dislocation still occurred in 8% of our patients.
Collapse
|
11
|
Erhardt JB, Roderer G, Grob K, Forster TN, Stoffel K, Kuster MS. Early results in the treatment of proximal humeral fractures with a polyaxial locking plate. Arch Orthop Trauma Surg 2009; 129:1367-74. [PMID: 19562356 DOI: 10.1007/s00402-009-0924-7] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/14/2008] [Indexed: 02/09/2023]
Abstract
OBJECTIVES We report early results using a second generation locking plate, non-contact bridging plate (NCB PH((R)), Zimmer Inc. Warsaw, IN, USA), for the treatment of proximal humeral fractures. The NCB PH combines conventional plating technique with polyaxial screw placement and angular stability. DESIGN Prospective case series. SETTING A single level-1 trauma center. PATIENTS A total of 50 patients with proximal humeral fractures were treated from May 2004 to December 2005. INTERVENTION Surgery was performed in open technique in all cases. MAIN OUTCOME MEASURES Implant-related complications, clinical parameters (duration of surgery, range of motion, Constant-Murley Score, subjective patient satisfaction, complications) and radiographic evaluation [union, implant loosening, implant-related complications and avascular necrosis (AVN) of the humeral head] at 6, 12 and 24 weeks. RESULTS All fractures available to follow-up (48 of 50) went to union within the follow-up period of 6 months. One patient was lost to follow-up, one patient died of a cause unrelated to the trauma, four patients developed AVN with cutout, one patient had implant loosening, three patients experienced cutout and one patient had an axillary nerve lesion (onset unknown). The average age- and gender-related Constant Score (n = 35) was 76. CONCLUSIONS The NCB PH combines conventional plating technique with polyaxial screw placement and angular stability. Although the complication rate was 19%, with a reoperation rate of 12%, the early results show that the NCB PH is a safe implant for the treatment of proximal humeral fractures.
Collapse
|
12
|
Gille J, Schulz AP, Queitsch C, Paech A, Jürgens C. Initial results of the s3-humerus plate. Open Orthop J 2008; 2:133-6. [PMID: 19478892 PMCID: PMC2687125 DOI: 10.2174/1874325000802010133] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/02/2008] [Revised: 07/29/2008] [Accepted: 08/12/2008] [Indexed: 11/22/2022] Open
Abstract
Fractures of the humeral head account for 5% of all fractures and incidence increases with age. Depending on fracture form and patients age a wide variety of therapeutical options exist. Stable fractures can be treated conservatively, while the majority of unstable and displaced fractures require surgical treatment. Many different surgical options are available; open reduction and internal fixation are widely preferred. The S3 Proximal Humerus Plate is a contoured plate to match the complex shape of the proximal humerus. It is designed to be positioned distal to the greater tuberosity preventing subacromial impingement. Between august 1 and 30, 2007, 5 patients meeting the inclusion criteria (that is primary operative stabilization within 7 days after trauma in a standardized way and minimal follow up period of 3 month) with acute fractures of the proximal humerus were treated with S3 Proximal Humerus Plate. Follow up was performed using the Constant Score. The mean age was 59.0 years. According to the Neer classification fractures were rated as Neer 2,3 and 4. A mean Constant score of 72.3 (57-86) points was obtained. We did not observe any complications like humeral head necroses, loss of reduction, deep infection or breakage of the plate.
Collapse
Affiliation(s)
- J Gille
- BG-Trauma Hospital Hamburg, Bergedorfer Str., 10, D-21033 Hamburg, Germany
| | | | | | | | | |
Collapse
|
13
|
Voigt C, Hurschler C, Althainz J, Vosshenrich R, Lill H. Die additive Zuggurtung der Rotatorenmanschette bei der winkelstabilen Plattenosteosynthese am proximalen Humerus. Unfallchirurg 2008; 111:514-22. [DOI: 10.1007/s00113-008-1439-3] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
14
|
Schoepp C, Oswald D, Schofer M, Kortmann HR. Standardverfahren zur Behandlung proximaler Humerusfrakturen. ACTA ACUST UNITED AC 2008. [DOI: 10.1007/s10039-008-1369-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
15
|
|