Theopold J, Henkelmann R, Zhang C, Schöbel T, Osterhoff G, Hepp P. Clinical outcomes of arthroscopic and navigation-assisted two tunnel technique for coracoclavicular ligament augmentation of acute acromioclavicular joint dislocations.
BMC Musculoskelet Disord 2021;
22:528. [PMID:
34107940 PMCID:
PMC8191052 DOI:
10.1186/s12891-021-04406-2]
[Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/25/2021] [Accepted: 04/26/2021] [Indexed: 11/12/2022] Open
Abstract
Background
The purpose of this study was to present a navigated image-free augmentation technique for the acromioclavicular joint (ACJ) and coracoclavicular (CC) ligaments and to report the clinical and radiological outcomes.
Methods
From 2013 to 2018, 35 eligible patients were treated with our navigated image-free ACJ- and CC-augmentation technique. The average follow-up was 3 years. Follow-up evaluations included the Constant-Murley Score, subjective shoulder value, Taft score, and the acromioclavicular joint instability (ACJI) score. The patients’ quality of life was assessed using the EuroQol-5D (EQ-5D) questionnaire. In addition, in accordance with the instability criteria, radiographs were evaluated before surgery, after surgery, and during follow-up.
Results
Overall, 25 patients (71%) suffered an acute type V disruption, 5 (14%) had a type IV disruption, and 5 (14%) had an acute Rockwood type IIIb injury. The mean Constant-Murley Score was 90 (range: 56–100; p = 0.53) on the injured side, and the mean subjective shoulder value was 92% (range: 80–100%). The mean Taft and ACJI scores were 10 (range: 4–12) and 86 (range: 34–100), respectively and the mean EQ-5D was 86 (range: 2–100). The mean CC difference of the injured side was 4 mm (range: 1.9–9.1 mm) at follow-up, which was not significantly different than that of the healthy side (p = 0.06). No fractures in the area of the clavicle or the coracoid were reported.
Conclusions
The arthroscopic- and navigation-assisted treatment of high-grade ACJ injuries in an anatomical double-tunnel configuration yields similar clinical and radiological outcomes as the conventional technique using an aiming device. Precise positioning of the navigation system prevents multiple drillings, which avoids fractures.
Supplementary Information
The online version contains supplementary material available at 10.1186/s12891-021-04406-2.
Collapse