1
|
Bliemel C, Cornelius J, Lehmann V, Oberkircher L, Visser D, Pass B, Ruchholtz S, Bäumlein M. Titanium Cable Cerclage Increases the Load to Failure in Plate Osteosynthesis for Distal Femoral Fractures. MEDICINA (KAUNAS, LITHUANIA) 2024; 60:1524. [PMID: 39336565 PMCID: PMC11434472 DOI: 10.3390/medicina60091524] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/15/2024] [Revised: 08/21/2024] [Accepted: 09/03/2024] [Indexed: 09/30/2024]
Abstract
Background and Objectives: The reduction of two-part oblique or spiral fractures of the distal femur using steel wire cerclage prior to plate osteosynthesis is a proven procedure. In addition to being useful in fracture reduction, wire cerclage was also shown to increase the stability of osteosynthesis. Nevertheless, metal corrosion and the allergenic potency of steel remain problematic disadvantages of this method. A biomechanical study was carried out to evaluate titanium cable cerclage as an alternative supplement for plate osteosynthesis of a distal femoral two-part fracture. Materials and Methods: An unstable AO/OTA 32-A2.3 fracture was created in eleven pairs of nonosteoporotic human cadaver femora. All the samples were treated with polyaxial angular stable plate osteosynthesis. One femur from each pair was randomly selected for an additional fracture fixation with multifilament titanium cable cerclage. Stepwise cyclic axial loading was applied in a load-to-failure mode using a servohydraulic testing machine. Results: All specimens (mean age: 80 years; range: 57-91 years) withstood a cycling force of at least 1800 N. With a mean load of 2982 N (95% CI: 2629-3335 N), the pressure forces resulting in osteosynthesis failure were significantly higher in specimens with an additional titanium cerclage (Group 1) than in samples that were solely treated with plate osteosynthesis (Group 2) at 2545 N (95% CI: 2257-2834 N) (p = 0.024). In both groups, cutting out the distal screws at the condyle region, resulting in shearing of the distal fragment proximal to the fracture line, was the most frequent cause of construct failure. Among the specimens assigned to Group 1, 36% exhibited a specific fracture pattern, namely, a fracture of the dorsal buttress above the cerclage. Analysis of axial stiffness (p = 0.286) and irreversible deformity of the specimens revealed no differences between the groups (p = 0.374). Conclusion: Titanium cable cerclage application, as a supplement to an angular stable plate, resulted in an increased load to failure. In terms of stability, the use of this adjunct for fracture fixation of supracondylar two-part oblique femoral fractures might, therefore, be an option, especially in patients who are sensitive to nickel.
Collapse
Affiliation(s)
- Christopher Bliemel
- Center for Orthopaedics and Trauma Surgery, University Hospital Giessen and Marburg, Baldingerstrasse, 35043 Marburg, Germany
- Philipps-University Marburg, 35037 Marburg, Germany
| | - Jakob Cornelius
- Center for Orthopaedics and Trauma Surgery, University Hospital Giessen and Marburg, Baldingerstrasse, 35043 Marburg, Germany
- Philipps-University Marburg, 35037 Marburg, Germany
| | - Valerie Lehmann
- Center for Orthopaedics and Trauma Surgery, University Hospital Giessen and Marburg, Baldingerstrasse, 35043 Marburg, Germany
- Philipps-University Marburg, 35037 Marburg, Germany
| | - Ludwig Oberkircher
- Philipps-University Marburg, 35037 Marburg, Germany
- Clinic for Trauma and Orthopaedic Surgery and Joint Replacement, Medical Campus Bodensee, 88048 Friedrichshafen, Germany
| | - Denis Visser
- Center for Orthopaedics and Trauma Surgery, University Hospital Giessen and Marburg, Baldingerstrasse, 35043 Marburg, Germany
- Philipps-University Marburg, 35037 Marburg, Germany
| | - Bastian Pass
- Department of Orthopedic and Emergency Surgery, Alfried Krupp Hospital Essen, 45131 Essen, Germany
| | - Steffen Ruchholtz
- Center for Orthopaedics and Trauma Surgery, University Hospital Giessen and Marburg, Baldingerstrasse, 35043 Marburg, Germany
- Philipps-University Marburg, 35037 Marburg, Germany
| | - Martin Bäumlein
- Center for Orthopaedics and Trauma Surgery, University Hospital Giessen and Marburg, Baldingerstrasse, 35043 Marburg, Germany
- Philipps-University Marburg, 35037 Marburg, Germany
| |
Collapse
|
2
|
Fleischhacker E, Sprecher CM, Milz S, Saller MM, Wirz R, Zboray R, Parrilli A, Gleich J, Siebenbürger G, Böcker W, Ockert B, Helfen T. Inflammatory tissue response in human soft tissue is caused by a higher particle load near carbon fiber-reinforced PEEK compared to titanium plates. Acta Biomater 2024; 180:128-139. [PMID: 38636789 DOI: 10.1016/j.actbio.2024.04.023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2023] [Revised: 03/19/2024] [Accepted: 04/11/2024] [Indexed: 04/20/2024]
Abstract
Titanium as the leading implant material in locked plating is challenged by polymers such as carbon fiber-reinforced polyetheretherketone (CFR-PEEK), which became the focus of interest of researchers and manufacturers in recent years. However, data on human tissue response to these new implant materials are rare. Osteosynthesis plates and peri‑implant soft tissue samples of 16 healed proximal humerus fractures were examined (n = 8 CFR-PEEK, n = 8 titanium). Soft tissue was analyzed by immunohistochemistry and µCT. The entrapped foreign bodies were further examined for their material composition by FTIR. To gain insight into their origin and formation mechanism, explanted and new plates were evaluated by SEM, EDX, profilometry and HR-CT. In the peri‑implant soft tissue of the CFR-PEEK plates, an inflammatory tissue reaction was detected. Tissues contained foreign bodies, which could be identified as tantalum wires, carbon fiber fragments and PEEK particles. Titanium particles were also found in the peri‑implant soft tissue of the titanium plates but showed a less intense surrounding tissue inflammation in immunohistochemistry. The surface of explanted CFR-PEEK plates was rougher and showed exposed and broken carbon fibers as well as protruding and deformed tantalum wires, especially in used screw holes, whereas scratches were identified on the titanium plate surfaces. Particles were present in the peri‑implant soft tissue neighboring both implant materials and could be clearly assigned to the plate material. Particles from both plate materials caused detectable tissue inflammation, with more inflammatory cells found in soft tissue over CFR-PEEK plates than over titanium plates. STATEMENT OF SIGNIFICANCE: Osteosynthesis plates are ubiquitously used in various medical specialties for the reconstruction of bone fractures and defects and are therefore indispensable for trauma surgeons, ENT specialists and many others. The leading implant material are metals such as titanium, but recently implants made of polymers such as carbon fiber-reinforced polyetheretherketone (CFR-PEEK) have become increasingly popular. However, little is known about human tissue reaction and particle generation related to these new implant types. To clarify this question, 16 osteosynthesis plates (n = 8 titanium and n = 8 CFR-PEEK) and the overlying soft tissue were analyzed regarding particle occurrence and tissue inflammation. Tissue inflammation is clinically relevant for the development of scar tissue, which is discussed to cause movement restrictions and thus contributes significantly to patient outcome.
Collapse
Affiliation(s)
- E Fleischhacker
- Department of Orthopedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), LMU University Hospital, LMU Munich, Germany.
| | - C M Sprecher
- AO Research Institute Davos, Clavadelerstrasse 8, 7270 Davos, Switzerland
| | - S Milz
- Anatomische Anstalt der Ludwig-Maximilians-Universität, Pettenkoferstrasse 11, 80336 München, Germany
| | - M M Saller
- Department of Orthopedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), LMU University Hospital, LMU Munich, Germany
| | - R Wirz
- RMS Foundation, Bischmattstrasse 12, 2544, Bettlach, Switzerland
| | - R Zboray
- EMPA, Überlandstrasse 129, Dübendorf, Switzerland
| | - A Parrilli
- EMPA, Überlandstrasse 129, Dübendorf, Switzerland
| | - J Gleich
- Department of Orthopedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), LMU University Hospital, LMU Munich, Germany
| | - G Siebenbürger
- Department of Orthopedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), LMU University Hospital, LMU Munich, Germany
| | - W Böcker
- Department of Orthopedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), LMU University Hospital, LMU Munich, Germany
| | - B Ockert
- Department of Orthopedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), LMU University Hospital, LMU Munich, Germany
| | - T Helfen
- Department of Orthopedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), LMU University Hospital, LMU Munich, Germany
| |
Collapse
|
3
|
Fleischhacker E, Sprecher CM, Milz S, Saller MM, Gleich J, Siebenbürger G, Helfen T, Böcker W, Ockert B. Functional outcomes before and after implant removal in patients with posttraumatic shoulder stiffness and healed proximal humerus fractures: does implant material (PEEK vs. titanium) have an impact? - a pilot study. BMC Musculoskelet Disord 2022; 23:95. [PMID: 35086539 PMCID: PMC8796509 DOI: 10.1186/s12891-022-05061-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/22/2021] [Accepted: 01/24/2022] [Indexed: 11/25/2022] Open
Abstract
Background Posttraumatic shoulder stiffness remains a problem after proximal humerus fracture (PHF) despite good healing rates. The aim of this pilot study was to determine whether the implant material and overlying soft tissue have an effect on shoulder range of motion (ROM) before and after implant removal (IR). Methods 16 patients (mean age 55.2 ± 15.3 (SD) years; 62.5% female) were included who underwent operative treatment with locking plates of either carbon fiber reinforced Polyetheretherketone (PEEK) (PEEKPower® humeral fracture plate, Arthrex, Naples, Florida, USA, n = 8) or titanium alloy (Ti) (Philos®, DePuy Synthes, Johnson & Johnson Medical, Raynham, Massachusetts, USA, n = 8) for PHF. All patients presented with a limited ROM and persistent pain in everyday life after the fracture had healed, whereupon IR was indicated. ROM before and after IR were compared as well as the Constant Score (CS) and the CS compared to the contralateral shoulder (%CS) 1 year after IR. Results In group PEEK, elevation was 116.3° ± 19.2° pre- and 129.4° ± 23.7° post-IR (p = 0.027). External rotation was 35.0° ± 7.6° pre- and 50.6° ± 21.8° post-IR (p = 0.041). External rotation with the humerus abducted 90° was 38.8° ± 18.1° pre- and 52.5° ± 25.5° post-IR (p = 0.024). In group Ti, elevation was 110.0° ± 34.6° pre- and 133.8° ± 31.1° post-IR (p = 0.011). External rotation with the humerus at rest was 33.8° ± 23.1° pre- and 48.8° ± 18.7° post-IR (p = 0.048). External rotation with the humerus abducted 90° was 40.0° ± 31.6° pre- and 52.5° ± 22.5° post-IR (p = 0.011). Comparison of the two implant materials showed no significant difference. The overall CS was 90.3 ± 8.8, the %CS was 91.8% ± 14.7%. Conclusion There was no significant difference in ROM, CS and %CS with respect to plate materials, although lower cell adhesion is reported for the hydrophobic PEEK. However, all patients showed improved functional outcomes after IR in this pilot study. In patients with shoulder stiffness following locked plating for PHF, implants should be removed and open arthrolysis should be performed, independently from the hardware material. Level of evidence II Supplementary Information The online version contains supplementary material available at 10.1186/s12891-022-05061-x.
Collapse
Affiliation(s)
- E Fleischhacker
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany.
| | | | - S Milz
- Anatomische Anstalt der Ludwig-Maximilians-Universität, Munich, Germany
| | - M M Saller
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - J Gleich
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - G Siebenbürger
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - T Helfen
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - W Böcker
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - B Ockert
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| |
Collapse
|
4
|
Thomas P, Summer B, Thyssen JP. Hypersensitivity Reactions to Orthopedic Implants. Contact Dermatitis 2021. [DOI: 10.1007/978-3-030-36335-2_80] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
5
|
Thomas P, Summer B, Thyssen JP. Orthopedic Implants. Contact Dermatitis 2020. [DOI: 10.1007/978-3-319-72451-5_80-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
6
|
Thomas P, Summer B, Thyssen JP. Hypersensitivity Reactions to Orthopedic Implants. Contact Dermatitis 2020. [DOI: 10.1007/978-3-319-72451-5_80-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
7
|
Furrer S, Scherer Hofmeier K, Grize L, Bircher AJ. Metal hypersensitivity in patients with orthopaedic implant complications-A retrospective clinical study. Contact Dermatitis 2018; 79:91-98. [PMID: 29888396 DOI: 10.1111/cod.13032] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2018] [Revised: 04/15/2018] [Accepted: 04/19/2018] [Indexed: 12/29/2022]
Abstract
BACKGROUND Hypersensitivity to metals as a cause of implant-related complications has been a subject of controversy. Projections indicate an increase in the frequency of joint replacements of between 300% and 600% by the year 2030; therefore, this issue is of considerable interest. OBJECTIVE To evaluate sensitization to implant materials in patients with implant-related complications, to identify allergens, and to clarify whether hypersensitivity is a relevant cause. METHODS Patients with implant-related complications or a positive history of contact allergy and planned total joint replacements referred for allergological investigation between 2004 and 2017 were retrospectively analysed. RESULTS In total, 311 patients were included. A positive patch test reaction to a metal was seen in 64.4% of preoperative patients and in 54.6% of patients with implant-related complications. Common alloy metals such as cobalt, chromium and titanium gave positive reactions in up to 2.9% of patients with implant-related complications. None of the patients with skin changes had a positive patch test reaction to an implant metal. CONCLUSION Other factors, such as the type of replaced joint and mechanical stress, seem to be more relevant for implant-related complications. Sensitization to metals or other materials seems to rarely play a role, and is overestimated.
Collapse
Affiliation(s)
- Stefan Furrer
- Department of Dermatology, Allergy Unit, University Hospital, Basel, Switzerland
| | | | - Leticia Grize
- Swiss Tropical and Public Health Institute, Basel, Switzerland.,University of Basel, Basel, Switzerland
| | - Andreas J Bircher
- Department of Dermatology, Allergy Unit, University Hospital, Basel, Switzerland.,University of Basel, Basel, Switzerland
| |
Collapse
|
8
|
Abstract
Routine implant removal is frequently performed although evidence-based guidelines are lacking. But routinely planned implant removal has significant economic implications and shows considerable complication rates. In general, clinical outcome seems to improve but pain relief after operation is often unpredictable. Even in patients reporting implant-related pain, implant removal does not guarantee relief and may be associated with further complications. The intra- and postoperative complication rate remains very high. Implant removal demonstrates a significant learning curve and unsupervised junior surgeons tend to cause more complications. The need for implant removal may be questioned. Even with the implant in place, contact activities can be resumed. However, a new adequate trauma can create a new fracture independently if there is an implant in-situ or not. It is important to understand the complications and outcomes to be expected with hardware removal to carefully evaluate its indication.
Collapse
Affiliation(s)
- Yves P Acklin
- Universitätsspital Basel, Department of Orthopaedics and Traumatology, Basel, Switzerland.
| | - Andreas Bircher
- University Hospital Basel, Department of Infectiology and Allergology, Basel, Switzerland
| | - Mario Morgenstern
- Universitätsspital Basel, Department of Orthopaedics and Traumatology, Basel, Switzerland
| | | | - Christoph Sommer
- Kantonsspital Graubünden, Department of Traumatology, Chur, Switzerland
| |
Collapse
|