1
|
Hönle W, Scheller A, Goyal T, Schuh A. [Painful total hip arthroplasty - operative and conservative therapy]. MMW Fortschr Med 2019; 161:66-70. [PMID: 31691217 DOI: 10.1007/s15006-019-1064-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Affiliation(s)
- Wolfgang Hönle
- Muskuloskelettales Zentrum Klinikum Neumarkt, Akademisches Lehrkrankenhaus der Friedrich-Alexander-Universität Erlangen-Nürnberg, Nürnberger Str. 12, D-92318, Neumarkt i. d. OPf., Deutschland.
| | - Alexander Scheller
- Muskuloskelettales Zentrum Klinikum Neumarkt, Akademisches Lehrkrankenhaus der Friedrich-Alexander-Universität Erlangen-Nürnberg, Nürnberger Str. 12, D-92318, Neumarkt i. d. OPf., Deutschland
| | - Tarun Goyal
- Muskuloskelettales Zentrum Klinikum Neumarkt, Akademisches Lehrkrankenhaus der Friedrich-Alexander-Universität Erlangen-Nürnberg, Nürnberger Str. 12, D-92318, Neumarkt i. d. OPf., Deutschland
| | - Alexander Schuh
- Muskuloskelettales Zentrum Klinikum Neumarkt, Akademisches Lehrkrankenhaus der Friedrich-Alexander-Universität Erlangen-Nürnberg, Nürnberger Str. 12, D-92318, Neumarkt i. d. OPf., Deutschland
| |
Collapse
|
2
|
D'Angelo F, Tanas D, Gallazzi E, Zagra L. Adverse reaction to metal debris after small-head diameter metal-on-metal total hip arthroplasty: an increasing concern. Hip Int 2018; 28:35-42. [PMID: 30755124 DOI: 10.1177/1120700018812993] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
INTRODUCTION: Failures due to adverse reaction to metal debris (ARMD) have become an area of common focus among surgeons performing hip replacements. Several authors have reported data on the prevalence of these masses, in both symptomatic and asymptomatic patients after either large-diameter head metal-on-metal (MoM) total hip arthroplasty (THA) or hip resurfacing arthroplasty, with a large variability of rate. To our knowledge, few data are reported on the association of this lesion with the use of small-head diameter MoM. METHODS: 15 hips that were revised for ARMD in small-head MoM THA were included in this study. We focused our attention on the difficulties of diagnosis and treatment and also on the histologic aspects of the harvested pathologic tissue. RESULTS: The histological examination of our cases showed a presence of lymphocytic infiltrate suggesting a delayed hypersensitivity reaction to the metal of type IV (ALVAL), but different from each other in term of the prevalence of the cellular component. Osteolysis and severe soft tissue damage were also observed. Revision resulted in remission of the lesion and successful implant. CONCLUSIONS: Our observation suggests that the evidence of ARMD should be considered even in case of small-head MoM arthroplasty and therefore these patients should be followed scrupulously with 2nd level diagnostic tools such as magnetic resonance imaging with metal artifact reduction sequence (MARS-MRI) and metal ion levels at least once. Further investigations are necessary to establish the real prevalence of this phenomenon in the whole population of small-head MoM THAs.
Collapse
Affiliation(s)
- Fabio D'Angelo
- 1 Department of Biotechnologies and Life Sciences, Division of Orthopaedics and Traumatology, University of Insubria, Italy
| | - Davide Tanas
- 1 Department of Biotechnologies and Life Sciences, Division of Orthopaedics and Traumatology, University of Insubria, Italy
| | - Enrico Gallazzi
- 2 Hip Department, I.R.C.C.S. Galeazzi Orthopaedic Institute, Milan, Italy
| | - Luigi Zagra
- 3 IRCCS Istituto Ortopedico Galeazzi, Hip Department, Milan, Italy
| |
Collapse
|
3
|
Abstract
Osteosynthesis materials or artificial joint replacement make part of clinical routine. In case of complaints mostly mechanical causes or infections are found. Metals like nickel, chromium and cobalt or bone cement components like acrylates and gentamicine may however potentially cause intolerance reactions to implants. Correspondingly, eczema, delayed wound/bone healing, recurrent effusion, pain or implant loosening have been described as manifestation of implant allergy. In contrast to the high incidence of cutaneous metal allergy, allergies associated with implants are rare. Diagnosis of metal implant allergy is based on excluding differential diagnoses – in particular infection – and on a combined approach of allergological diagnostics by patch test and histopathology of periimplant tissue. Risk factors for allergic sensitization to implants or triggering periimplant allergic reactions in the case of preexisting cutaneous metal allergy are unknown. Despite the risk of developing complications being unclear, titanium-based osteosynthesis materials are recommended for metal-allergic patients and the use of metal-metal couplings in arthroplasty is rather not recommended for such patients. If a regular, potentially applicable CoCr-polyethylene articulation is preferred, the patient has to be well informed and has to give his written consent.
Collapse
|
4
|
Thomas P, Weik T, Roider G, Summer B, Thomsen M. Influence of Surface Coating on Metal Ion Release: Evaluation in Patients With Metal Allergy. Orthopedics 2016; 39:S24-30. [PMID: 27219723 DOI: 10.3928/01477447-20160509-08] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/07/2016] [Accepted: 02/03/2016] [Indexed: 02/03/2023]
Abstract
Nickel, chromium, and cobalt in stainless steel and Cobalt-chrome-molybdenum (CoCrMo) alloys may induce allergy. The objectives of this study were to evaluate surface coating regarding ion release, patch test reactivity, and arthroplasty performance. Materials and methods included patch test in 31 patients with metal allergy and 30 patients with no allergy to stainless steel and CoCrMo disks that are uncoated or coated by titanium nitride/zirconium nitride (TiN/ZrN). Assessment include atomic absorption spectrometry of released nickel, cobalt, and chromium from the disks after exposure to distilled water, artificial sweat and culture medium. Results showed that both coatings reduced the nickel and chromium release from stainless steel and CoCrMo disks and mostly the cobalt release from the disks (maximally 11.755 µg/cm(2)/5 d to 1.624 by Ti-N and to 0.442 by ZrN). Six of the 31 patients with metal allergy reacted to uncoated disks, but none reacted to the coated disks. The current authors report on exemplary patients with metal allergy who had symptom relief by revision with surface-coated arthroplasty. The authors concluded that the surface coating may prevent cutaneous and peri-implant allergic reactions. [Orthopedics. 2016; 39(3):S24-S30.].
Collapse
|
5
|
Stiehler M, Zobel F, Hannemann F, Schmitt J, Lützner J, Kirschner S, Günther KP, Hartmann A. [Complications of metal-on-metal tribological pairing]. DER ORTHOPADE 2014; 43:79-91. [PMID: 24356820 DOI: 10.1007/s00132-013-2131-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
BACKGROUND Metal-on-metal (MoM) tribological pairing results in less volumetric abrasion than pairing with the conventionally used polyethylene and is associated with a lower risk of material failure compared to other hard-hard pairings. An increased frequency of problem cases in recent years has led to a great increase in uncertainty. Against this background in this article the current aspects of epidemiology, etiology, diagnostics and treatment of complications in MoM hip joint endoprostheses will be discussed. EPIDEMIOLOGY AND ETIOLOGY Based on the results from national endoprosthesis registers and selected clinical studies an evaluation of the rate of local complications from MoM tribological pairings was undertaken. A differentiation was made between MoM pairings in pedicled small head prostheses (≤ 32 mm), large head (> 32 mm) and surface replacement (OFE) endoprostheses. Each year MoM endoprostheses release on average 10(12)-10(14) cobalt (Co) and chromium (Cr) nanoparticles per patient. This release of metal ions and particles can lead to a variety of tissue reactions. DIAGNOSTICS A differentiation must be made between regular routine diagnostics within the framework of implant follow-up screening and specific investigations due to the occurrence of complaints. The diagnostics for patients treated with MoM hip endoprostheses consists of a standardized step-wise approach considering possible differential diagnoses and the utilization of modern laboratory chemical and radiological methods. When problems occur, a differentiation should preferentially be made between complaints not caused by metal and mechanical problems (e.g. prosthesis loosening and impingement) and symptoms due to periprosthetic infections. THERAPY OF COMPLICATIONS The normal standards for hip endoprosthetics are also valid for periprosthetic infections, fractures and other general complications. Specific measures are, however, necessary for complications due to metal-specific risks.
Collapse
Affiliation(s)
- M Stiehler
- UniversitätsCentrum für Orthopädie und Unfallchirurgie, Klinik für Orthopädie, Universitätsklinikum Carl Gustav Carus, TU Dresden, Fetscherstr. 74, 01307, Dresden, Deutschland
| | | | | | | | | | | | | | | |
Collapse
|
6
|
Thomsen M, Kretzer JP, Krenn V, Thomas P. [Different symptoms in patients with prostheses with metal-metal bearings]. DER ORTHOPADE 2014; 42:637-42. [PMID: 23907450 DOI: 10.1007/s00132-012-2037-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Based on several clinical case examples, this article demonstrates the different symptoms and complications in patients fitted with prostheses with metal-on-metal (MoM) bearings. We recommend an annual clinical control for patients with MoM prostheses with a prosthesis head size of 36 mm or larger. In patients who have problems tests should be carried out to measure the metal ion levels of cobalt and chromium and the metal artifact-reduced sequence by magnetic resonance imaging (MRI) or if this is not possible an ultrasound investigation. The clinical investigations should specifically target asymptomatic local swellings or hardened sites and patients should be questioned on problems with general hypersensitivity reactions (skin rash), cardiomyopathy, neurological changes including sensory changes, renal function impairment and thyroid dysfunction.
Collapse
Affiliation(s)
- M Thomsen
- Klinik für Orthopädie und Unfallchirurgie, DRK-Klinik Baden-Baden, Lilienmattstraße 5, 76530, Baden-Baden, Deutschland.
| | | | | | | |
Collapse
|
7
|
Abstract
Increasing data are available describing risk factors for the development of local and systemic adverse events following operations using metal-on-metal (MoM) hip implants. The prevalence and clinical relevance of metal-associated problems are, however, still under debate. They can be influenced by type and position of implant as well as patient-specific factors. Patients with small MoM heads (maximum diameter 32 mm) and subgroups of resurfacing arthroplasty can achieve good long-term survival. The use of large head MoM implants (diameters greater than 36 mm), however, is currently not advised due to the unsatisfactory results.
Collapse
|
8
|
Allergiediagnostik bei Verdacht auf Metallimplantatunverträglichkeit. DER ORTHOPADE 2013; 42:602-6. [DOI: 10.1007/s00132-012-2033-5] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
9
|
Pospischill M, Knahr K. Strategies for head and inlay exchange in revision hip arthroplasty. INTERNATIONAL ORTHOPAEDICS 2010; 35:261-5. [PMID: 21088833 DOI: 10.1007/s00264-010-1164-8] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/10/2010] [Revised: 11/02/2010] [Accepted: 11/02/2010] [Indexed: 10/18/2022]
Abstract
Due to the increasing number of total hip arthroplasties performed during the last three decades and the limited long-term survival, mainly because of wear, the number of revisions has increased during the last two years. If the implant itself is still considered to be stable, only head and inlay exchange is necessary. This requires comprehensive knowledge of the characteristics of the articulating materials by the surgeon as the wrong choice of wear couple can lead to early failure for a second time. The aim of this paper is to present considerations and strategies for head and inlay exchange in case of failure, either due to wear of the articulation material or of other indications for revision hip arthroplasty.
Collapse
Affiliation(s)
- Martin Pospischill
- Orthopedic Hospital Vienna-Speising, Speisingerstr. 109, 1130, Vienna, Austria.
| | | |
Collapse
|
10
|
Saito S, Ishii T, Mori S, Hosaka K, Ootaki M, Tokuhashi Y. Long-term results of metasul metal-on-metal total hip arthroplasty. Orthopedics 2010; 33. [PMID: 20704108 DOI: 10.3928/01477447-20100625-11] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
We assessed 90 total hip arthroplasties (THAs) performed with the Metasul metal-on-metal hip system (Zimmer, Warsaw, Indiana); the patients were monitored for >10 years. The average Harris Hip Score of the patients was 40.5 points preoperatively and 85.8 points at final follow-up. No adverse reactions to the metal debris were observed in patients presenting with symptoms or phenomena such as unexplained pain, joint effusion, bursitis, or pseudotumor. Radiographically, the acetabular component fixation was stable in 86 hips, possibly unstable in 3 hips, and unstable in 1 hip. The unstable hip required revision of the acetabular component. The femoral component was bone-ingrown in 81 hips and stable-fibrous in 9 hips. Distal femoral cortical hypertrophy was seen in 34.4% of hips.Postoperatively, 6 hips dislocated, of which 2 developed recurrent dislocation and required revision of the acetabular component. Dissociation of the polyethylene liner occurred in 2 hips 6 and 12 years postoperatively, respectively, and required revision of the polyethylene liner and the articular head. The survival rate with the endpoint defined as revision surgery and radiologic loosening was 94.4% at mean follow-up (12.3 years). This study found that the Metasul metal-on-metal THA produces excellent long-term results.
Collapse
Affiliation(s)
- Shu Saito
- Department of Orthopedic Surgery, Nihon University School of Medicine, Tokyo, Japan.
| | | | | | | | | | | |
Collapse
|
11
|
|
12
|
Thomas P, Braathen LR, Dörig M, Auböck J, Nestle F, Werfel T, Willert HG. Increased metal allergy in patients with failed metal-on-metal hip arthroplasty and peri-implant T-lymphocytic inflammation. Allergy 2009; 64:1157-65. [PMID: 19220218 DOI: 10.1111/j.1398-9995.2009.01966.x] [Citation(s) in RCA: 128] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
BACKGROUND In 16 patients with revised metal-on-metal arthroplasty and peri-implant lymphocytic inflammation, we verified the role of metal hypersensitivity by patch testing (PT) and lymphocyte transformation test (LTT). METHODS In the 16 patients with lymphocyte dominated periprosthetic inflammation, allergy history was obtained by a questionnaire, specific serum IgE to aeroallergens was measured to assess atopy, PT to standard and metal series was performed and metal sensitivity was further assessed by LTT using blood mononuclear cells. RESULTS Revision surgery was performed because of pain (8/16), osteolysis (4/16), dislocation (3/16) and loosening of the stem (1/16). Histological examination showed perivascular infiltrates of T lymphocytes, high endothelial venules, fibrin exudation and accumulation of macrophages with drop-like inclusions. Five patients had a history of cutaneous metal allergy and atopy was found in 25% of the patients. In 13/16 patients (81%), systemic metal sensitivity was found based on PT and/or LTT. Patch test reactions were seen in 11/16 patients (69%; partly multiple reactions/patient): 7/16 to Cobalt (Co), 7/16 to Chromium (Cr), 4/16 to Nickel (Ni), and one each to Molybdenum (Mo) and Manganese (Mn). Ten of 16 patients (62%) showed enhanced LTT reactivity to metals: 7/16 to Ni, 7/16 to Co, 5/16 to Cr, 5/16 to Mo and 4/16 to Mn. CONCLUSIONS The lymphocyte dominated peri-implant inflammation may well reflect an allergic hyper-reactivity in these patients, given the high rate of concomitantly found metal allergy. Despite the overall incidence of metal implant allergy being low, allergic reactions should be included as differential diagnosis in failed metal-on-metal arthroplasty.
Collapse
Affiliation(s)
- P Thomas
- Department of Dermatology and Allergology, Ludwig-Maximilians-University Munich, Frauenlobstr. 9-11, Munich 80337, Germany
| | | | | | | | | | | | | |
Collapse
|
13
|
Witte F, Calliess T, Windhagen H. [Biodegradable synthetic implant materials : clinical applications and immunological aspects]. DER ORTHOPADE 2009; 37:125-30. [PMID: 18214423 DOI: 10.1007/s00132-008-1193-9] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
In the last decade biodegradable synthetic implant materials have been established for various clinical applications. Ceramic materials such as calcium phosphate, bioglass and polymers are now routinely used as degradable implants in the clinical practice. Additionally these materials are now also used as coating materials or as microspheres for controlled drug release and belong to a series of examples for applications as scaffolds for tissue engineering. Because immense local concentrations of degradation products are produced during biodegradation, this review deals with the question whether allergic immune reactions, which have been reported for classical metallic and organic implant materials, also play a role in the clinical routine for synthetic biodegradable materials. Furthermore, possible explanatory theories will be developed to clarify the lack of clinical reports on allergy or sensitization to biodegradable synthetic materials.
Collapse
Affiliation(s)
- F Witte
- Labor für Biomechanik und Biomaterialien, Orthopädische Klinik der Medizinischen Hochschule Hannover, Anna-von-Borries-Str. 1-7, 30625, Hannover, Deutschland.
| | | | | |
Collapse
|
14
|
Rau C, Thomas P, Thomsen M. [Metal sensitivity in patients with joint replacement arthroplasties before and after surgery]. DER ORTHOPADE 2009; 37:102-10. [PMID: 18210091 DOI: 10.1007/s00132-007-1186-0] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
The object of the present study was to determine the incidence of metal sensitivity in patients with joint replacement arthroplasties before and after surgery and whether this is of significance as regards the final outcome of the operative procedure. A questionnaire-based survey involved 1,335 patients with an average age of 61 years and joint replacement arthroplasties before and after surgery. A history of dermal sensitivity to metal was given in 99 (7%) patients with almost equal frequency in the pre- and postoperative groups (7.6 vs 7.2%). In only 27 of 99 cases was the metal sensitivity recorded in the patient chart. In 46 cases investigation was done after knee or hip replacement arthroplasty with an average implant time in situ of 68 months. In 32 of 46 patients a sensitivity to the implanted material was known and they did not show any complications related to the metal sensitivity.It is currently unclear whether metal sensitivity could be induced by joint replacement arthroplasties and it remains uncertain whether loosening or infection causes the sensitization as a consequence of increased release of metal ions or vice versa. To draw further conclusions considerably more detailed studies involving more patients are clearly indicated.
Collapse
Affiliation(s)
- C Rau
- Abteilung Orthopädie I, Orthopädische Universitätsklinik, Heidelberg, Deutschland
| | | | | |
Collapse
|
15
|
Traina F, De Fine M, Biondi F, Tassinari E, Galvani A, Toni A. The influence of the centre of rotation on implant survival using a modular stem hip prosthesis. INTERNATIONAL ORTHOPAEDICS 2008; 33:1513-8. [PMID: 19099304 DOI: 10.1007/s00264-008-0710-0] [Citation(s) in RCA: 57] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/22/2008] [Revised: 11/21/2008] [Accepted: 11/21/2008] [Indexed: 11/25/2022]
Abstract
The restoration of the hip centre of rotation in an anatomical position is considered to be relevant for total hip prosthesis survival. When the cup is implanted with a high centre of rotation, the lever arm of the abductor muscles is decreased, causing higher joint-reaction forces. Modular stems with varying lengths and geometries can be used to balance soft tissues, and ceramic bearing surfaces can be used to reduce the wear rate. Forty-four hip replacements performed with a high hip centre of rotation were matched with 44 performed with an anatomical centre of rotation. In all cases the preoperative diagnosis was dysplasia of the hip (DDH) and cementless modular neck prostheses with ceramic bearing surfaces were used. At nine years follow-up the mean Harris hip and WOMAC scores were not statistically different. All stems and cups were stable; the femoral offset was no different between the two groups (p = 0.4) as leg-length discrepancy (p = 0.25).
Collapse
Affiliation(s)
- Francesco Traina
- 1st Department of Orthopaedic Surgery and Laboratory of Medical Technology (LTM), Istituti Ortopedici Rizzoli, Via Pupilli 1, Bologna, Italy, 40136.
| | | | | | | | | | | |
Collapse
|
16
|
Abstract
Modern metal-on-metal bearings show very low wear rates but release particles and ions from the articulating surfaces into the joint and the whole organism. Especially during the run-in period an increased number of particles is produced. The released metal ions potentially trigger cytotoxic, cancerogenic and allergic reactions, which can impair the patient's health locally or systemically. Many surgeons fear a hypersensitivity reaction to the metal ions of the CoCr alloy in their patients. Today it is assumed that the incidence of these implant-related complications is very low but in some cases it will lead to early failure of the implant. Because the available alternative bearing combinations (ceramic-on-polyethylene and ceramic-on-ceramic) also bear the risk of severe complications, a final statement on the best and safest bearing choice for the patient cannot be made based on the currently existing data.
Collapse
|
17
|
[Orthopedic surgical implants and allergies. Joint statement by the Implant Allergy Working Group (AK 20) of the DGOOC (German Association of Orthopedics and Orthopedic Surgery), DKG (German Contact Dermatitis Research Group) and DGAKI (German Society for Allergology and Clinical Immunology)]. Hautarzt 2008; 59:220-9. [PMID: 18210000 DOI: 10.1007/s00105-007-1453-3] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
Materials used in osteosynthesis or artificial joint replacement are usually well tolerated. Complaints after such operations are mostly related to infection or mechanical problems but may also be caused by allergic reactions. The latter encompass skin changes, e.g., eczema, delayed wound/bone healing, recurrent effusion, pain, or implant loosening. In contrast to the high incidence of cutaneous metal contact allergy, allergies associated with implants are a rare condition. However, epidemiological data on the incidence of implant-related allergic reactions are still missing. Typical elicitors are nickel, chromium, cobalt, and constituents of bone cement (acrylates und additives such as gentamicin or benzoyl peroxide). After exclusion of the most common differential diagnoses, allergy diagnostic procedures are primarily based on patch tests including a metal and bone cement component series. Additional analysis of periimplant tissue is recommended. However, further studies are necessary to show the significance of the histologic findings and the role of the lymphocyte transformation test (LTT). Which combinations of factors will induce allergic sensitization to implants or trigger periimplant allergic reactions in the case of preexisting cutaneous metal allergy is still unknown. Titanium-based osteosynthesis materials are recommended for metal allergic patients. In elective hip replacements, a ceramic/polyethylene (PE) articulation should be used, and in knee replacements "alternative materials". If a regular, potentially applicable CoCr/PE articulation is preferred, the patient must be well informed and must give his/her written consent.
Collapse
|
18
|
Thomas P, Thomsen M. Allergiediagnostik bei Metallimplantatunverträglichkeit. DER ORTHOPADE 2008; 37:131-5. [DOI: 10.1007/s00132-008-1194-8] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
19
|
|
20
|
Treudler R, Simon JC. Benzoyl peroxide: is it a relevant bone cement allergen in patients with orthopaedic implants? Contact Dermatitis 2007; 57:177-80. [PMID: 17680868 DOI: 10.1111/j.1600-0536.2007.01195.x] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Contact allergies to orthopaedic implant material are discussed to be relevant for postoperative complaints. We aimed at determining the prevalence of sensitizations to implant metals and to bone cements in patients with implants. We investigated 13 consecutive patients with suspicion of contact allergy to implant material. Epicutaneous patch testing was performed with metals and bone cement components including benzoyl peroxide (BPO). The chief complaints were skin disorders (n = 3), loosening of implant (n = 2), swelling (n = 6), and pain (n = 2). 6 patients had a sensitization to at least 1 allergen. 3 patients reacted to BPO, being of possible relevance in 1 of these patients suffering from dermatitis. Other sensitizations, such as those to nickel, fragrance, and balsam of Peru, were observed, with no clinical relevance (n = 1, respectively). BPO in bone cements may lead to type 4 sensitizations of which the relevance, however, remains questionable. Nevertheless we recommend this allergen to be tested in patients with complicated cemented orthopaedic implants.
Collapse
Affiliation(s)
- Regina Treudler
- Department of Dermatology, niversitätsklinikum Leipzig A.ö.R, Leipzig 04103, Germany.
| | | |
Collapse
|
21
|
Summer B, Fink U, Zeller R, Rueff F, Maier S, Roider G, Thomas P. Patch test reactivity to a cobalt?chromium?molybdenum alloy and stainless steel in metal-allergic patients in correlation to the metal ion release. Contact Dermatitis 2007; 57:35-9. [PMID: 17577355 DOI: 10.1111/j.1600-0536.2007.01139.x] [Citation(s) in RCA: 49] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Nickel, chromium, and cobalt released from stainless steel and CoCrMo alloys have been postulated to trigger hypersensitivity reactions. The objective of this study was to assess the ion release from a CoCrMo alloy and stainless steel in vitro and the cutaneous reactivity to it by patch test. 52 metal-allergic patients and 48 non-allergic controls were patch tested to stainless steel and CoCrMo discs. In addition, using atomic absorption spectrometry, the release of nickel, cobalt, and chromium from both materials was assessed upon 2-day exposure to distilled water, artificial sweat (AS), and cell culture medium. There was low nickel ion release from stainless steel (0.3-0.46 microg/cm(2)/2 days) and CoCrMo discs (up to 0.33 microg/cm(2)/2 days) into the different elution media. Chromium release from the 2 materials was also very low (0.06-0.38 microg/cm(2)/2 days from stainless steel and 0.52-1.36 microg/cm(2)/2 days from CoCrMo alloy). In contrast, AS led to abundant cobalt release (maximally 18.94 microg/cm(2)/2 days) from the CoCrMo discs, with concomitant eczematous reaction upon patch testing: 0 of the 52 metal-allergic patients reacted to stainless steel discs and 5 of the 52 patients to CoCrMo discs (all 5 patients were cobalt allergic and 3 also nickel and chromium allergic). None of the controls reacted to the discs. Apart from nickel being a focus of allergological research, our results point to the possibly underestimated association of cobalt release and potential hyperreactivity to CoCrMo alloy.
Collapse
Affiliation(s)
- Burkhard Summer
- Klinik und Poliklinik für Dermatologie und Allergologie der, Ludwig-Maximilians-Universität München, Frauenlobstr. 9-11, D-80337 München, Germany.
| | | | | | | | | | | | | |
Collapse
|
22
|
Riedel F, Hönle W, Göske J, Kachler W, Holzwarth U, Schuh A. [Examination of granuloma of revised cemented or cementless total hip arthroplasties using inductively coupled plasma atomic emission spectrometry (ICP-OES)]. BIOMED ENG-BIOMED TE 2006; 51:15-20. [PMID: 16771125 DOI: 10.1515/bmt.2006.004] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
INTRODUCTION Aseptic loosening is the most common problem in total hip arthroplasty (THA). One main aspect is inflammatory reaction against wear particles of the prosthesis materials. Analysing failure mechanisms in THA analysis of the particles and their element distribution of revised granulomatous tissue is essential to improve materials used in THA. MATERIALS AND METHODS 23 granulomas of revised THA due to aseptic loosening, 13 of which with metal on metal bearing (M/M), were analysed using inductively coupled plasma atomic emission spectrometry (ICP-OES). RESULTS Elements Cr, Mn, Ni, Al, Cu, Zn, Cd, Ti, V, Zr, Nb and Fe could be detected. The maximum value of Cr was 23.88 ppb (parts per billion), Al 191.02 ppb, Ni 64.95 ppb and Zr 9.96 ppb. The highest value of Al could be found in cementless implants. The maximum value of the elements Cr and Ni could be detected in M/M. In cemented implants the highest value of Zr was found. DISCUSSION The origin of Zr was the used bone cement in cemented THA. The elements Cr and Ni were significantly higher in M/M bearings. The highest value of Al was detected in granulomas of revised corund rough blasted cementless implants. The histopathologic findings of the revised M/M bearings have been published recently. Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-OES) could not show any differences of the alloying constituents in cases with or without allergic reactions. ICP-OES analysis seems to be not useful examination of histologic sections using SEM with cryotransfer unit.
Collapse
Affiliation(s)
- Frank Riedel
- Orthopädische Klinik Rummelsberg, Schwarzenbruck, Deutschland.
| | | | | | | | | | | |
Collapse
|