1
|
Thomas P, Arenberger P, Bader R, Bircher AJ, Bruze M, de Graaf N, Hartmann D, Johansen JD, Jowitz-Heinke A, Krenn V, Kurek M, Odgaard A, Rustemeyer T, Summer B, Thyssen JP. A literature review and expert consensus statement on diagnostics in suspected metal implant allergy. J Eur Acad Dermatol Venereol 2024; 38:1471-1477. [PMID: 38606660 DOI: 10.1111/jdv.20026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2023] [Accepted: 03/11/2024] [Indexed: 04/13/2024]
Abstract
BACKGROUND Although rare, allergic reactions to metal implants represent a diagnostic challenge in view of missing guidelines. OBJECTIVES To develop an European expert consensus on characteristics of metal allergy reactions and the utility of various diagnostic tools in suspected metal implant allergy. METHODS A nominal group technique (NGT) was applied to develop consensus statements. Initially an online literature database was created on a secure server to enable a comprehensive information. Twenty-three statements were formulated on potential aspects of metal implant allergy with a focus on diagnostics and grouped into five domains. For the consensus development, the panel of 12 experts initially did refine and reformulate those statements that were ambiguous or had unclear wording. By face-to-face (9/12) or virtual participation (3/12), an anonymous online voting was performed. RESULTS Consensus (≥80% of agreement) was reached in 20/23 statements. The panel agreed that implant allergy despite being rare should be considered in case of persistent unexplained symptoms. It was, however, recommended to allow adequate time for resolution of symptoms associated with healing and integration of an implant. Obtaining questionnaire-aided standardized medical history and standardized scoring of patient outcomes was also considered an important step by all experts There was broad consensus regarding the utility/performance of patch testing with additional late reading. It was recognized that the lymphocyte transformation test (LTT) has to many limitations to be generally recommended. Prior to orthopaedic implant, allergy screening of patients without a history of potential allergy to implant components was not recommended. CONCLUSIONS Using an expert consensus process, statements concerning allergy diagnostics in suspected metal implant allergy were created. Areas of nonconsensus were identified, stressing uncertainty among the experts around topics such as preoperative testing in assumed allergy, histological correlate of periimplant allergy and in vitro testing, which underscores the need for further research.
Collapse
Affiliation(s)
- P Thomas
- Department of Dermatology and Allergology, University Hospital, Munich, Germany
| | - P Arenberger
- Department of Dermatovenereology, Third Faculty of Medicine, Charles University and University Hospital of Kralovske Vinohrady, Prague, Czech Republic
| | - R Bader
- Department of Orthopaedics, Rostock University Medical Center, Rostock, Germany
| | - A J Bircher
- Department of Dermatology and Allergology, University Hospital and University of Basel, Basel, Switzerland
| | - M Bruze
- Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden
| | - N de Graaf
- Department of Dermatology, VU University Medical Center, Amsterdam, The Netherlands
| | - D Hartmann
- Department of Dermatology and Allergology, University Hospital, Munich, Germany
- München Klinik gGmbH, Munich, Germany
| | - J D Johansen
- Department of Dermatology and Allergy, National Allergy Research Centre, University of Copenhagen, Herlev and Gentofte Hospital, Hellerup, Denmark
| | - A Jowitz-Heinke
- Department of Orthopaedics, Rostock University Medical Center, Rostock, Germany
| | - V Krenn
- MVZHZMD Trier GmbH, Trier, Germany
| | - M Kurek
- Hospital MEDICAM, Gryfice, Poland
| | - A Odgaard
- Department of Orthopaedic Surgery, Rigshospitalet - Copenhagen University Hospital, Copenhagen, Denmark
- Institute of Clinical Medicine, Copenhagen University, Copenhagen, Denmark
| | - T Rustemeyer
- Department of Dermatology, VU University Medical Center, Amsterdam, The Netherlands
| | - B Summer
- Department of Dermatology and Allergology, University Hospital, Munich, Germany
| | - J P Thyssen
- Department of Dermatology and Allergy, University of Copenhagen, Herlev and Gentofte Hospital, Hellerup, Denmark
| |
Collapse
|
2
|
Postler A, Beyer F, Lützner C, Tille E, Lützner J. [The use of knee prostheses with a hypoallergenic coating is safe in the medium term : A randomized controlled study]. DER ORTHOPADE 2021; 51:660-668. [PMID: 34734297 PMCID: PMC9352637 DOI: 10.1007/s00132-021-04186-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Accepted: 10/11/2021] [Indexed: 10/25/2022]
Abstract
BACKGROUND In Germany, patients with contact allergy to implant components usually receive coated joint arthroplasties. Whether the treatment using these hypoallergenic implants achieves comparable results to standard treatment with implants consisting of cobalt-chromium alloy (CoCr) implants is controversially discussed internationally and has rarely been investigated in the mid-term. OBJECTIVES Are there differences in blood metal ion concentrations, knee function, and patient-reported outcomes (PROM) between coated and standard implants? MATERIAL AND METHODS 118 patients were randomized to receive either a coated or a standard implant. Knee function as well as patient-reported outcome measures were assessed. Metal ion concentrations in blood samples were additionally determined for chromium, cobalt, molybdenum, and nickel, preoperatively, one and five years after surgery. RESULTS After five years, it was possible to analyse the results of 97 patients. In metal ion concentrations, as well as PRO, consistently good results were seen, without any difference between the groups. While in 13 patients there was an increase in chromium concentration above 2 µg/l one year after surgery, there was no measured value above 1 µg/l after five years. CONCLUSION In our study, similar mid-term results were detected for coated (TiNiN) and standard (CoCr)TKA. With respect to metal ion concentrations and PRO there are no disadvantages in using coated TKA.
Collapse
Affiliation(s)
- Anne Postler
- UniversitätsCentrum für Orthopädie, Unfall- und Plastische Chirurgie, Universitätsklinikum Carl Gustav Carus Dresden, TU Dresden, Fetscherstraße 74, 01307, Dresden, Deutschland.
| | - Franziska Beyer
- UniversitätsCentrum für Orthopädie, Unfall- und Plastische Chirurgie, Universitätsklinikum Carl Gustav Carus Dresden, TU Dresden, Fetscherstraße 74, 01307, Dresden, Deutschland
| | - Cornelia Lützner
- UniversitätsCentrum für Orthopädie, Unfall- und Plastische Chirurgie, Universitätsklinikum Carl Gustav Carus Dresden, TU Dresden, Fetscherstraße 74, 01307, Dresden, Deutschland
| | - Eric Tille
- UniversitätsCentrum für Orthopädie, Unfall- und Plastische Chirurgie, Universitätsklinikum Carl Gustav Carus Dresden, TU Dresden, Fetscherstraße 74, 01307, Dresden, Deutschland
| | - Jörg Lützner
- UniversitätsCentrum für Orthopädie, Unfall- und Plastische Chirurgie, Universitätsklinikum Carl Gustav Carus Dresden, TU Dresden, Fetscherstraße 74, 01307, Dresden, Deutschland
| |
Collapse
|
3
|
Brown A, Mandelberg NJ, Munoz-Mendoza D, Palys V, Schalock PC, Mogilner A, North R, A Petersen E. Allergy Considerations in Implanted Neuromodulation Devices. Neuromodulation 2021; 24:1307-1316. [PMID: 33428821 DOI: 10.1111/ner.13332] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2020] [Accepted: 11/24/2020] [Indexed: 12/14/2022]
Abstract
OBJECTIVES Allergic reactions are rare and poorly understood complications of neuromodulation device implantation. There are currently no guidelines for management of allergic reactions to these devices and their components. Here we review the published cases of allergic reactions to implanted neuromodulatory devices and leverage the experiences of other specialties that deal with similar complications to formulate recommendations for prevention and management. MATERIALS AND METHODS A review and assessment of the literature. RESULTS Allergic reactions to a number of implantable devices have been observed and published. In dentistry and orthopedics, metals such as nickel are the most frequent cause of allergic reactions. In interventional cardiology, where devices closely resemble neuromodulatory devices, titanium, silicone, and polyurethanes are the most common causes of allergic reactions. In neurosurgery, allergic reactions to implantable neuromodulatory devices are rare, and we summarize 13 cases published to date. Such allergic reactions generally present as local dermatitis, erythema, and pruritus, which can be difficult to distinguish from surgical site infection. In one published case, symptoms resolved with corticosteroid treatment, but all other cases required explantation. The successful reimplantation with a modified device was reported in some cases. CONCLUSIONS Patients should be screened for a personal history of contact allergy before implantation procedures. A multidisciplinary approach to suspected cases of postoperative allergic reactions involving collaboration between neurosurgeons and other implanting physicians, dermatologists or allergists, and device manufacturers is recommended. In cases where an allergic reaction is suspected, an infectious etiology should be ruled out first. Clinical suspicion can then be supported with the use of patch testing, interpreted by an experienced dermatologist or allergist. If patch testing supports an allergic etiology, the implanting physician and the device manufacturer can work together to modify the device for safe reimplantation.
Collapse
Affiliation(s)
- Austin Brown
- College of Medicine, University of Arkansas for Medical Sciences, Little Rock, AR, USA
| | | | - Diana Munoz-Mendoza
- Division of Pediatric Allergy, Department of Pediatrics, University of Arkansas for Medical Sciences, Arkansas Children's Hospital, Little Rock, AR, USA
| | - Viktoras Palys
- Department of Neurosurgery, University of Arkansas for Medical Sciences, Little Rock, AR, USA
| | - Peter C Schalock
- Department of Dermatology, Geisel School of Medicine at Dartmouth, Hanover, NH, USA
| | - Alon Mogilner
- Department of Neurosurgery, New York University Grossman School of Medicine, New York, NY, USA
| | - Richard North
- The Institute of Neuromodulation, Chicago, IL, USA.,The Neuromodulation Foundation, Baltimore, MD, USA.,The Johns Hopkins University School of Medicine (ret.), Baltimore, MD, USA
| | - Erika A Petersen
- Department of Neurosurgery, University of Arkansas for Medical Sciences, Little Rock, AR, USA
| |
Collapse
|
4
|
Tam I, Yu J, Ko LN, Schalock PC. Clinical factors before or after device implantation in predicting metal hypersensitivity reactions: A retrospective study. Contact Dermatitis 2020; 83:398-407. [DOI: 10.1111/cod.13637] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2020] [Revised: 05/28/2020] [Accepted: 06/09/2020] [Indexed: 12/14/2022]
Affiliation(s)
- Idy Tam
- Tufts University School of Medicine Boston Massachusetts
- Department of Dermatology Massachusetts General Hospital Boston Massachusetts
| | - JiaDe Yu
- Department of Dermatology Massachusetts General Hospital Boston Massachusetts
- Harvard School of Medicine Boston Massachusetts
| | - Lauren N. Ko
- Harvard Combined Dermatology Residency Harvard Medical School Boston Massachusetts
| | - Peter C. Schalock
- Department of Dermatology Geisel School of Medicine at Dartmouth Hanover New Hampshire
| |
Collapse
|
5
|
|
6
|
Schultzel M, Klein CM, Demirjian M, Blout C, Itamura JM. Incidence of Metal Hypersensitivity in Orthopedic Surgical Patients Who Self-Report Hypersensitivity History. Perm J 2019; 24:19.091. [PMID: 31852052 DOI: 10.7812/tpp/19.091] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
INTRODUCTION Metallic implants are integral to the practice of orthopedic surgery. Delayed-onset T-cell-mediated metal hypersensitivity (diagnosed by patch testing) is reported in 10% to 17% of the general population. Inconclusive evidence exists about the role of metal hypersensitivity in persistently painful or aseptic loosening of arthroplasties. Literature suggests that preoperative patch testing may influence surgical practice. OBJECTIVE To determine the incidence of metal hypersensitivity in orthopedic surgical patients who self-report hypersensitivity and to characterize which metals are most commonly implicated. METHODS A retrospective chart review of patients from a single surgeon's practice was conducted during a 1-year period. All patients were questioned about metal hypersensitivity history; all patients who responded affirmatively were sent for patch testing for specific metals. RESULTS Only 41 (4.9%) of 840 patients self-reported any metal hypersensitivity. Of these, 34 (83%) were patch-test positive to 1 or more metals. There were 27 whose test results were positive for nickel, 4 each to cobalt or gold thiosulfate, and 1 each to tin or titanium. Seven patients had positive results to multiple metals, all of whom were also nickel hypersensitive. Six patients had metal orthopedic implants before patch testing, and 4 (67%) tested positively to a metal in their implant. CONCLUSION Metal hypersensitivity can be concerning for treating surgeons and patients. Greater awareness of a history to hypersensitivity may prevent patient exposure to implants containing metals that may cause hypersensitivity. Non-metal-containing or nonreactive metal implants are an option for patients in whom metal hypersensitivity is suspected or confirmed.
Collapse
Affiliation(s)
- Mark Schultzel
- Southern California Permanente Medical Group, Orthopedic Medical Group of San Diego, Synergy Orthopedic Specialists Medical Group, San Diego
| | - Christopher M Klein
- Kerlan-Jobe Orthopaedic Clinic, White Memorial Medical Center, Cedars-Sinai Medical Center, Keck School of Medicine, Los Angeles, CA
| | - Marine Demirjian
- Department of Allergy and Immunology, University of California, Los Angeles
| | - Colin Blout
- Kerlan-Jobe Orthopaedic Clinic, White Memorial Medical Center, Cedars-Sinai Medical Center, Keck School of Medicine, Los Angeles, CA
| | - John M Itamura
- Kerlan-Jobe Orthopaedic Clinic, White Memorial Medical Center, Cedars-Sinai Medical Center, Keck School of Medicine, Los Angeles, CA
| |
Collapse
|
7
|
Abstract
There are very few reports of eczema and other prosthetic-related allergic skin complications following arthroplasty. We aimed to assess the risk of eczema after joint replacement.We performed a retrospective population-based cohort study in 2024 joint replacement patients using the Longitudinal Health Insurance Database. For comparison, 8096 controls were selected, with 4 control subjects for each joint replacement patient matched for age, sex, and index year, to assess eczema risk. We examined 14-year cumulative eczema incidence associated with age, sex, immunity, disease history, and joint replacement location.Eczema rates in the joint replacement patients were 38% higher than in the control group (57.90 vs 41.84 per 1000 person-years, respectively). Compared with the control group, joint replacement patients showed a 1.35-fold increased risk of eczema according to the multivariable Cox model (95% Confidence interval [CI] = 1.23-1.49). Knee replacement patients had higher eczema risk compared with the control group (Hazard ratio [HR] = 1.45, 95% CI = 1.33-1.70). Stratified by study period, the joint replacement cohort had a higher eczema risk after the 3-month follow-up.Our study revealed that joint arthroplasty increased risk of eczema in this 14-year follow-up study, and this was not related to personal atopic history or gender.
Collapse
Affiliation(s)
- Po-Yuan Wu
- Department of Dermatology, China Medical University Hospital
- School of Medicine, China Medical University
| | | | - Chun-Hao Tsai
- School of Medicine, China Medical University
- Department of Orthopedics, China Medical University Hospital
- Department of Sports Medicine/School of Medicine, China Medical University, Taichung, Taiwan
| |
Collapse
|
8
|
Henry A, Inverso G, Granquist EJ. Revision temporomandibular joint arthroplasty for the treatment of acquired metal allergy and review of the literature. Int J Oral Maxillofac Surg 2019; 49:356-360. [PMID: 31447220 DOI: 10.1016/j.ijom.2019.08.002] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2018] [Revised: 08/04/2019] [Accepted: 08/06/2019] [Indexed: 11/24/2022]
Abstract
The purpose of this study was to examine the outcomes of patients who received revision temporomandibular joint (TMJ) arthroplasty for the treatment of acquired metal allergy. It was hypothesized that subjects would have significant improvements in pain, swelling, and function. Patients who underwent TMJ revision due to nickel allergy were identified retrospectively. Outcomes documented included the presence or absence of facial erythema and facial swelling. Maximum incisal opening was also measured. Additional outcomes collected included age at initial surgery, initial TMJ device type, presenting symptoms, and TMJ device used for surgical revision. Four patients were identified with a nickel allergy to their TMJ prosthesis (containing nickel). All subjects experienced pain and swelling as their primary symptoms prior to the revision, with two subjects showing dermatological symptoms of overlying erythema. The four female subjects underwent exchange of their previously implanted prosthesis with a titanium alloy prosthesis. Postoperatively, all subjects showed improvements in pain score, resolution of swelling and erythema, and improvements in maximum incisal opening. This small case series suggests that revision TMJ arthroplasty with a titanium alloy prosthesis is a potential treatment for acquired metal allergy from traditional TMJ prosthesis implantation.
Collapse
Affiliation(s)
- A Henry
- Carolinas Center for Oral and Maxillofacial Surgery, Charlotte, NC, USA
| | - G Inverso
- Department of Oral and Maxillofacial Surgery, Hospital of the University of Pennsylvania, Philadelphia, PA, USA.
| | - E J Granquist
- Department of Oral and Maxillofacial Surgery, Hospital of the University of Pennsylvania, Philadelphia, PA, USA
| |
Collapse
|
9
|
Hönle W, Ndubuisi O, Scheller A, Jezussek D, Schuh A. [Painful total knee arthroplasty - operative and conservative therapy]. MMW Fortschr Med 2019; 161:56-64. [PMID: 31414471 DOI: 10.1007/s15006-019-0023-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Affiliation(s)
- Wolfgang Hönle
- Muskuloskelettales Zentrum Klinikum Neumarkt, Akademisches Lehrkrankenhaus der Friedrich-Alexander-Universität Erlangen-Nürnberg, Nürnberger Str. 12, D-92318, Neumarkt i. d. OPf., Deutschland.
| | - Onyemaechi Ndubuisi
- Department of Surgery, University of Nigeria Teaching Hospital Ituku-Ozalla Enugu, Enugu, Nigeria
| | - Alexander Scheller
- Muskuloskelettales Zentrum Klinikum Neumarkt, Akademisches Lehrkrankenhaus der Friedrich-Alexander-Universität Erlangen-Nürnberg, Nürnberger Str. 12, D-92318, Neumarkt i. d. OPf., Deutschland
| | - Damian Jezussek
- Muskuloskelettales Zentrum Klinikum Neumarkt, Akademisches Lehrkrankenhaus der Friedrich-Alexander-Universität Erlangen-Nürnberg, Nürnberger Str. 12, D-92318, Neumarkt i. d. OPf., Deutschland
| | - Alexander Schuh
- Muskuloskelettales Zentrum Klinikum Neumarkt, Akademisches Lehrkrankenhaus der Friedrich-Alexander-Universität Erlangen-Nürnberg, Nürnberger Str. 12, D-92318, Neumarkt i. d. OPf., Deutschland
| |
Collapse
|
10
|
Postler A, Beyer F, Lützner C, Tille E, Lützner J. Similar outcome during short-term follow-up after coated and uncoated total knee arthroplasty: a randomized controlled study. Knee Surg Sports Traumatol Arthrosc 2018; 26:3459-3467. [PMID: 29616285 DOI: 10.1007/s00167-018-4928-0] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/01/2017] [Accepted: 03/28/2018] [Indexed: 12/27/2022]
Abstract
PURPOSE Patients with known hypersensitivity to metals often require hypoallergenic TKA implants. Coating of a standard implant is a common solution, and although in vitro tests have demonstrated reduction of polyethylene wear for these coatings, it is still unknown whether these implants have any clinical benefit. This study was initiated to investigate metal ion concentrations, knee function and patient-reported outcome (PRO) after coated and uncoated TKA. METHODS One hundred and twenty-two (122) patients were randomized to receive a coated or a standard TKA and, after exclusions, 59 patients were included in each group. Knee function and PRO were assessed with validated scores up to 3 years after surgery. Metal ion concentrations in blood samples were determined for chromium, cobalt, molybdenum and nickel, preoperatively and 1 year after surgery. RESULTS Chromium concentrations in patient plasma increased from a median of 0.25 to 1.30 µg/l in the standard TKA group, and from 0.25 to 0.75 µg/l in the coated TKA group (p = 0.012). Thirteen patients (3 coated, 10 standard TKA) had chromium concentrations above 2 µg/l. The concentrations of cobalt, molybdenum and nickel did not change. Patient-reported outcome measures (PROM) demonstrated a substantial improvement after TKA, without any differences between the groups. CONCLUSION The increase in chromium concentration in the standard group needs further investigation. If surgeons use coated implants, they can be confident that these implants perform as well as standard implants. LEVEL OF EVIDENCE I.
Collapse
Affiliation(s)
- Anne Postler
- University Center of Orthopaedics and Traumatology, University Medicine Carl Gustav Carus Dresden, Fetscherstr. 74, 01307, Dresden, Germany
| | - Franziska Beyer
- University Center of Orthopaedics and Traumatology, University Medicine Carl Gustav Carus Dresden, Fetscherstr. 74, 01307, Dresden, Germany
| | - Cornelia Lützner
- University Center of Orthopaedics and Traumatology, University Medicine Carl Gustav Carus Dresden, Fetscherstr. 74, 01307, Dresden, Germany
| | - Eric Tille
- University Center of Orthopaedics and Traumatology, University Medicine Carl Gustav Carus Dresden, Fetscherstr. 74, 01307, Dresden, Germany
| | - Jörg Lützner
- University Center of Orthopaedics and Traumatology, University Medicine Carl Gustav Carus Dresden, Fetscherstr. 74, 01307, Dresden, Germany.
| |
Collapse
|
11
|
Hofmann SC, Plett M, Jansen S, Thomas P, Thölken KFM. Titanium hypersensitivity causing painful intra-abdominal oedema after staple-fixed inguinal hernia repair. Contact Dermatitis 2018. [PMID: 29521457 DOI: 10.1111/cod.12985] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Silke C Hofmann
- Centre for Dermatology, Allergy and Dermatosurgery, Helios University Hospital Wuppertal, University Witten/Herdecke, Wuppertal, Germany
| | - Maria Plett
- Centre for Dermatology, Allergy and Dermatosurgery, Helios University Hospital Wuppertal, University Witten/Herdecke, Wuppertal, Germany
| | - Stefan Jansen
- Centre for Visceral Surgery, Helios University Hospital Wuppertal, University Witten/Herdecke, Wuppertal, Germany
| | - Peter Thomas
- Department of Dermatology and Allergy, Ludwig-Maximilians-University, Munich, Germany
| | - Karisa F M Thölken
- Centre for Dermatology, Allergy and Dermatosurgery, Helios University Hospital Wuppertal, University Witten/Herdecke, Wuppertal, Germany
| |
Collapse
|
12
|
Hopf F, Thomas P, Sesselmann S, Thomsen MN, Hopf M, Hopf J, Krukemeyer MG, Resch H, Krenn V. CD3+ lymphocytosis in the peri-implant membrane of 222 loosened joint endoprostheses depends on the tribological pairing. Acta Orthop 2017; 88:642-648. [PMID: 28787254 PMCID: PMC5694809 DOI: 10.1080/17453674.2017.1362774] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - The most frequent cause of arthroplasty failure is aseptic loosening-often induced by particles. Abrasion material triggers inflammatory reactions with lymphocytic infiltration and the formation of synovial-like interface membranes (SLIM) in the bone-implant interface. We analyzed CD3 quantities in SLIM depending on articulating materials and possible influences of proven material allergies on CD3 quantities. Patients and methods - 222 SLIM probes were obtained from revision surgeries of loosened hip and knee arthroplasties. SLIM cases were categorized according to the SLIM-consensus classification and to the particle algorithm. The CD3 quantities were analyzed immunohistochemically, quantified, and correlated to the particle types. Results - Metal-metal pairings showed the highest CD3 quantities (mean 1,367 counted cells). CD3 quantities of metal-polyethylene (mean 243), ceramic-polyethylene (mean 182), and ceramic-ceramic pairings (mean 124) were significantly smaller. Patients with contact allergy to implant materials had high but not statistically significantly higher CD3 quantities than patients without allergies. For objective assessment of the CD3 response as result of a pronounced inflammatory reaction with high lymphocytosis (adverse reaction), a defined CD3 quantity per high power field was established, the "CD3 focus score" (447 cells/0.3 mm2, sensitivity 0.92; specificity 0.90; positive predictive value 0.71; negative predictive value 0.98). Interpretation - The high CD3 quantities for metal-metal pairings may be interpreted as substrate for previously described adverse reactions that cause severe peri-implant tissue destruction and SLIM formation. It remains unclear whether the low CD3 quantities with only slight differences in the various non-metal-metal pairings and documented contact allergies to implant materials have a direct pathogenetic relevance.
Collapse
Affiliation(s)
- Felix Hopf
- Center for Histopathology and Molecular Pathology, Trier, Germany
| | - Peter Thomas
- Department of Dermatology and Allergologie, Ludwig-Maximilians-University (LMU), Munich, Germany
| | - Stefan Sesselmann
- Department of Orthopaedic Surgery, Friedrich-Alexander-University of Erlangen-Nuremberg, Germany,Correspondence:
| | - Marc N Thomsen
- Clinic of Orthopaedic Medicine and Emergency Surgery, Klinikum Mittelbaden Baden-Baden Balg, Baden-Baden, Germany
| | - Maximilian Hopf
- Center for Histopathology and Molecular Pathology, Trier, Germany
| | - Johannes Hopf
- Department of Orthopaedics and Traumatology, Johannes Gutenberg University, Mainz, Germany
| | | | - Herbert Resch
- University Hospital for Trauma Surgery and Sports Traumatology, Salzburg, Austria
| | - Veit Krenn
- Center for Histopathology and Molecular Pathology, Trier, Germany
| |
Collapse
|
13
|
[Titanium or steel as osteosynthesis material : Systematic literature search for clinical evidence]. Unfallchirurg 2017; 120:96-102. [PMID: 28108750 DOI: 10.1007/s00113-016-0299-5] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
BACKGROUND The selection of the appropriate implant material, stainless steel or titanium, is still the decision of the surgeon and/or the affiliated institution. Additionally, remarkable international differences can be found between the different markets, which cannot really be explained. OBJECTIVE A systematic literature search was performed to verify whether there is clinical evidence for the preference of one material over the other. MATERIAL AND METHODS The systematic literature search was performed utilizing the internet databases PubMed, Cochrane and Web of Science. Comparative studies were included that reported on adult patients with osteosynthesis of extremities after trauma using either stainless steel or titanium implants. Information was extracted about infection rates, incidence of clinically relevant allergies, problems with implant removal and other complications. RESULTS A total of 18 publications were identified to be eligible and 2 referenced articles were added. In summary, there is insufficient clinical evidence that the use of titanium or steel implants has a positive or negative effect on fracture healing, shows different rates of allergies, different rates of infections or mechanical failure. No supporting evidence could be identified for the difficulties with removal of titanium implants reported by surgeons. CONCLUSION This systematic literature search did not provide any clinical evidence for material-related differences between titanium or stainless steel implants for fracture fixation. Based on the current clinical evidence both titanium and steel implants can be considered to be of equal value. The reported difficulties with implant removal are not reflected in the published literature.
Collapse
|
14
|
Abstract
Osteosynthesis materials or artificial joint replacement make part of clinical routine. In case of complaints mostly mechanical causes or infections are found. Metals like nickel, chromium and cobalt or bone cement components like acrylates and gentamicine may however potentially cause intolerance reactions to implants. Correspondingly, eczema, delayed wound/bone healing, recurrent effusion, pain or implant loosening have been described as manifestation of implant allergy. In contrast to the high incidence of cutaneous metal allergy, allergies associated with implants are rare. Diagnosis of metal implant allergy is based on excluding differential diagnoses – in particular infection – and on a combined approach of allergological diagnostics by patch test and histopathology of periimplant tissue. Risk factors for allergic sensitization to implants or triggering periimplant allergic reactions in the case of preexisting cutaneous metal allergy are unknown. Despite the risk of developing complications being unclear, titanium-based osteosynthesis materials are recommended for metal-allergic patients and the use of metal-metal couplings in arthroplasty is rather not recommended for such patients. If a regular, potentially applicable CoCr-polyethylene articulation is preferred, the patient has to be well informed and has to give his written consent.
Collapse
|
15
|
Abstract
Cranioplasty remains a difficult procedure for all craniofacial surgeons, particularly when concerning the reconstruction of large lacunae in the skull. Considering the significant clinical and economic impact of the procedure, the search for materials and strategies to provide more comfortable and reliable surgical procedures is one of the most important challenges faced by modern craniofacial medicine.The purpose of this study was to compare the available data regarding the safety and clinical efficacy of materials and techniques currently used for the reconstruction of the skull. Accordingly, the scientific databases were searched for the following keywords autologous bone, biomaterials, cranial reconstruction, cranioplasty, hydroxyapatite, polyetheretherketone, polymethylmethacrylate, and titanium. This literature review emphasizes the benefits and weaknesses of each considered material commonly used for cranioplasty, especially in terms of infectious complications, fractures, and morphological outcomes.As regards the latter, this appears to be very similar among the different materials when custom three-dimensional modeling is used for implant development, suggesting that this criterion is strongly influenced by implant design. However, the overall infection rate can vary from 0% to 30%, apparently dependent on the type of material used, likely in virtue of the wide variation in their chemico-physical composition. Among the different materials used for cranioplasty implants, synthetics such as polyetheretherketone, polymethylmethacrylate, and titanium show a higher primary tear resistance, whereas hydroxyapatite and autologous bone display good biomimetic properties, although the latter has been ascribed a variable reabsorption rate of between 3% and 50%.In short, all cranioplasty procedures and materials have their advantages and disadvantages, and none of the currently available materials meet the criteria required for an ideal implant. Hence, the choice of cranioplasty materials is still essentially reliant on the surgeon's preference.
Collapse
|
16
|
Hartmann D, Letulé V, Schneider JJ, Flaig MJ. [Metal implant sensitivity: clinical and histological presentation]. Hautarzt 2017; 67:373-9. [PMID: 27090521 DOI: 10.1007/s00105-016-3790-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Metal implant sensitivity (intolerance) can cause pain, reduced mobility, loosening of the implant and skin rashes. Knowledge of differential diagnoses, histology and appropriate diagnostics are essential for proper diagnosis. To outline typical clinical signs and histology in metal-implant-associated skin lesions we present three exemplary patients from our implant allergy outpatient department and give an overview of the current literature regarding metal implant sensitivity. In patients with a negative patch test the lymphocyte transformation test may reveal metal sensitization. Even "pure" titanium alloys may contain traces of nickel. The histology of implant-associated skin reactions goes from teleangiectatic postimplantation erythema to eczema and vasculitis. Based on the synopsis of history, clinical picture, allergological testing and histology, metal implant sensitivity can be diagnosed more precisely.
Collapse
Affiliation(s)
- D Hartmann
- Klinik und Poliklinik für Dermatologie und Allergologie, Ludwig-Maximilians-Universität München, Frauenlobstr. 9-11, München, Deutschland.
| | - V Letulé
- Klinik und Poliklinik für Dermatologie und Allergologie, Ludwig-Maximilians-Universität München, Frauenlobstr. 9-11, München, Deutschland
| | - J J Schneider
- Klinik und Poliklinik für Dermatologie und Allergologie, Ludwig-Maximilians-Universität München, Frauenlobstr. 9-11, München, Deutschland
| | - M J Flaig
- Klinik und Poliklinik für Dermatologie und Allergologie, Ludwig-Maximilians-Universität München, Frauenlobstr. 9-11, München, Deutschland
| |
Collapse
|
17
|
Thomsen M, Krenn V, Thomas P. [Adverse reactions to metal orthopedic implants after knee arthroplasty]. Hautarzt 2017; 67:347-51. [PMID: 27116434 DOI: 10.1007/s00105-016-3793-3] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
Based on several clinical examples, the range of adverse or hypersensitive reactions to metal implants especially after total knee replacement are presented. In general, we found the patients to generally be women who present with pain, swelling, and local or generalized eczema. Some also present with early aseptic loosening mainly in the first 4 years after implantation. For these patients, a detailed allergy-specific history should be taken and a patch test should be performed; if necessary, blood ion levels should be evaluated to exclude cobaltism. Before revision surgery and exchange of the implant we always perform arthroscopic inspection to obtain biopsies for microbiology and histopathology. Using the Consensus Classification a good evaluation for planning revision with the different implant options is possible.
Collapse
Affiliation(s)
- M Thomsen
- Klinik für Orthopädie und Unfallchirurgie, Klinikum Mittelbaden Baden-Baden, Balger Str. 50, 76532, Baden-Baden, Deutschland.
| | - V Krenn
- Zentrum für Histologie, Zytologie und Molekulare Diagnostik, Max-Planck-Str. 5, 54296, Trier, Deutschland
| | - P Thomas
- Klinik und Poliklinik für Dermatologie und Allergologie, Ludwig-Maximilians-Universität München, Frauenlobstr. 9-11, 80337, München, Deutschland
| |
Collapse
|
18
|
Teo WZW, Schalock PC. Metal Hypersensitivity Reactions to Orthopedic Implants. Dermatol Ther (Heidelb) 2017; 7:53-64. [PMID: 27995484 PMCID: PMC5336431 DOI: 10.1007/s13555-016-0162-1] [Citation(s) in RCA: 48] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2016] [Indexed: 01/08/2023] Open
Abstract
Total hip and knee replacement surgery using metal alloy devices is common. Type IV allergic reactions to these implants occur, though infrequently. While uncommon, peri-implant metal allergic reactions may cause significant morbidity for the affected individual-including aseptic loosening, pseudotumor formation and frank device failure. It is challenging to predict who will have these reactions, even in those with established pre-implant metal allergy. At this time, the scientific literature clearly supports few conclusions. Despite this, we believe several conclusions can be made: routine pre-implant testing in asymptomatic individuals is not indicated; listen to patient's concerns about metal allergy if the concern arises; patch testing is probably the best pre- and post-implant screening test; post-implantation testing is controversial and even positive LTT or patch test does not definitively diagnose morbidity from a metal allergy; and complete recovery following revision placement of an immunologically inert device is diagnostic. More research is needed to scientifically approach this issue.
Collapse
Affiliation(s)
- Wendy Z W Teo
- Department of Surgery (Dermatology), Geisel School of Medicine at Dartmouth, Hanover, NH, USA
| | - Peter C Schalock
- Department of Surgery (Dermatology), Geisel School of Medicine at Dartmouth, Hanover, NH, USA.
| |
Collapse
|
19
|
|
20
|
Ajwani SH, Charalambous CP. Availability of Total Knee Arthroplasty Implants for Metal Hypersensitivity Patients. Knee Surg Relat Res 2016; 28:312-318. [PMID: 27894179 PMCID: PMC5134788 DOI: 10.5792/ksrr.16.018] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/07/2016] [Revised: 04/19/2016] [Accepted: 05/19/2016] [Indexed: 12/18/2022] Open
Abstract
Purpose To provide information on the type of "hypersensitivity-friendly" components available for primary total knee arthroplasty (TKA) in the current market. Materials and Methods Implant manufactures were identified using the 2013 National Joint Registries of the United Kingdom and Sweden and contacted to obtain information about the products they offer for patients with metal hypersensitivity. Results Information on 23 TKA systems was provided by 13 implant manufacturers. Of these, 15 systems had options suitable for metal hypersensitivity patients. Two types of "hypersensitivity-friendly" components were identified: 10 implants were cobalt chrome prostheses with a "hypersensitivity-friendly" outer coating and 5 implants were made entirely from non-cobalt chrome alloys. Conclusions The results of this study suggest that several hypersensitivity TKA options exist, some of which provide the same designs and surgical techniques as the conventional implants. The information in this study can guide TKA surgeons in making informed choices about implants and identifying implants that could be examined in future controlled studies comparing outcomes between "hypersensitivity-friendly" and conventional implants.
Collapse
Affiliation(s)
- Sanil Harji Ajwani
- Department of Orthopaedics, Blackpool Teaching Hospitals NHS Foundation Trust, Blackpool, UK
| | - Charalambos P Charalambous
- Department of Orthopaedics, Blackpool Teaching Hospitals NHS Foundation Trust, Blackpool, UK.,School of Medicine and Dentistry, University of Central Lancashire, Preston, UK.,Institute of Inflammation and Repair, School of Medical and Human Sciences, University of Manchester, Manchester, UK
| |
Collapse
|
21
|
Beyer F, Lützner C, Kirschner S, Lützner J. Midterm Results After Coated and Uncoated TKA: A Randomized Controlled Study. Orthopedics 2016; 39:S13-7. [PMID: 27219721 DOI: 10.3928/01477447-20160509-10] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/21/2016] [Accepted: 02/03/2016] [Indexed: 02/03/2023]
Abstract
Patients undergoing total knee arthroplasty (TKA) who have hypersensitivity to metals usually receive hypoallergenic TKA implants. Coating of a standard implant is a common solution. Although in vitro tests have demonstrated reduction in polyethylene wear for these coatings, it is unknown whether these costly implants have a clinical benefit for patients. One hundred twenty patients undergoing TKA were randomly assigned to receive a novel 7-layer-coating implant or a standard TKA implant. One revision occurred in the standard group, resulting in a calculated 5-year survival of 100% in the coated group and 98.1% in the standard group. The Oxford Knee Score improved substantially in both groups from a mean of 21.6 points preoperatively in the coated group and 21.9 points in the standard group to 39.2 points and 39.2 points, respectively. The current authors observed no adverse effects with the new coating during midterm follow-up. However, longer follow-up time is needed to evaluate possible advantages of this coating. [Orthopedics. 2016; 39(3):S13-S17.].
Collapse
|
22
|
Thomas P, Weik T, Roider G, Summer B, Thomsen M. Influence of Surface Coating on Metal Ion Release: Evaluation in Patients With Metal Allergy. Orthopedics 2016; 39:S24-30. [PMID: 27219723 DOI: 10.3928/01477447-20160509-08] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/07/2016] [Accepted: 02/03/2016] [Indexed: 02/03/2023]
Abstract
Nickel, chromium, and cobalt in stainless steel and Cobalt-chrome-molybdenum (CoCrMo) alloys may induce allergy. The objectives of this study were to evaluate surface coating regarding ion release, patch test reactivity, and arthroplasty performance. Materials and methods included patch test in 31 patients with metal allergy and 30 patients with no allergy to stainless steel and CoCrMo disks that are uncoated or coated by titanium nitride/zirconium nitride (TiN/ZrN). Assessment include atomic absorption spectrometry of released nickel, cobalt, and chromium from the disks after exposure to distilled water, artificial sweat and culture medium. Results showed that both coatings reduced the nickel and chromium release from stainless steel and CoCrMo disks and mostly the cobalt release from the disks (maximally 11.755 µg/cm(2)/5 d to 1.624 by Ti-N and to 0.442 by ZrN). Six of the 31 patients with metal allergy reacted to uncoated disks, but none reacted to the coated disks. The current authors report on exemplary patients with metal allergy who had symptom relief by revision with surface-coated arthroplasty. The authors concluded that the surface coating may prevent cutaneous and peri-implant allergic reactions. [Orthopedics. 2016; 39(3):S24-S30.].
Collapse
|
23
|
|
24
|
Banke IJ, Stade N, Prodinger PM, Mühlhofer HM, Thomas P, Thomas B, Summer B, van Griensven M, von Eisenhart-Rothe R, Gollwitzer H. [Synovial biomarkers for differential diagnosis of painful arthroplasty]. DER ORTHOPADE 2015; 44:93, 936-8, 940-1. [PMID: 26542406 DOI: 10.1007/s00132-015-3188-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
BACKGROUND The diagnosis and treatment of periprosthetic joint infection (PJI) remain true clinical challenges. PJI diminishes therapeutic success, causes dissatisfaction for the patient and medical staff, and often requires extensive surgical revision(s). At the present time, an extensive multimodal algorithmic approach is used to avoid time- and cost-consuming diagnostic aberrations. However, especially in the case of the frequent and clinically most relevant "low-grade" PJI, the current diagnostic "gold standard" has reached its limits. EVALUATION Synovial biomarkers are thought to close this diagnostic gap, hopefully enabling the safe differentiation among aseptic, (chronic) septic, implant allergy-related and the arthrofibrotic genesis of symptomatic arthroplasty. Therefore, joint aspiration for obtaining synovial fluid is preferred over surgical synovial tissue biopsy because of the faster results, greater practicability, greater patient safety, and lower costs. In addition to the parameters synovial IL-6, CRP, and leukocyte esterase, novel biomarkers such as antimicrobial peptides and other proinflammatory cytokines are currently highlighted because of their very high to excellent diagnostic accuracy. CONCLUSION Independent multicenter validation studies are required to show whether a set of different innovative synovial fluid biomarkers rather than a few single parameters is favorable for a safe "one-stop shop" differential diagnosis of PJI.
Collapse
Affiliation(s)
- I J Banke
- Klinik und Poliklinik für Orthopädie und Sportorthopädie, Klinikum rechts der Isar der TU München, Ismaninger Str. 22, 81675, München, Deutschland.
| | - N Stade
- Klinik und Poliklinik für Orthopädie und Sportorthopädie, Klinikum rechts der Isar der TU München, Ismaninger Str. 22, 81675, München, Deutschland
| | - P M Prodinger
- Klinik und Poliklinik für Orthopädie und Sportorthopädie, Klinikum rechts der Isar der TU München, Ismaninger Str. 22, 81675, München, Deutschland
| | - H M Mühlhofer
- Klinik und Poliklinik für Orthopädie und Sportorthopädie, Klinikum rechts der Isar der TU München, Ismaninger Str. 22, 81675, München, Deutschland
| | - P Thomas
- Klinik und Poliklinik für Dermatologie und Allergologie der LMU München, Frauenlobstraße 9-11, 80337, München, Deutschland
| | - B Thomas
- Klinik und Poliklinik für Dermatologie und Allergologie der LMU München, Frauenlobstraße 9-11, 80337, München, Deutschland
| | - B Summer
- Klinik und Poliklinik für Dermatologie und Allergologie der LMU München, Frauenlobstraße 9-11, 80337, München, Deutschland
| | - M van Griensven
- Experimentelle Unfallchirurgie, Klinik und Poliklinik für Unfallchirurgie, Klinikum rechts der Isar der TU München, Ismaninger Str. 22, 81675, München, Deutschland
| | - R von Eisenhart-Rothe
- Klinik und Poliklinik für Orthopädie und Sportorthopädie, Klinikum rechts der Isar der TU München, Ismaninger Str. 22, 81675, München, Deutschland
| | - H Gollwitzer
- Klinik und Poliklinik für Orthopädie und Sportorthopädie, Klinikum rechts der Isar der TU München, Ismaninger Str. 22, 81675, München, Deutschland.,ATOS Klinik München, Effnerstr. 38, 81925, München, Deutschland
| |
Collapse
|
25
|
Allergic reactions in arthroplasty: myth or serious problem? INTERNATIONAL ORTHOPAEDICS 2015; 40:239-44. [PMID: 26526701 DOI: 10.1007/s00264-015-3001-6] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/10/2015] [Accepted: 09/14/2015] [Indexed: 12/20/2022]
Abstract
PURPOSE The purpose of this study was to determine the prevalence of sensitisation to chromium, cobalt, nickel, or a cement component in patients who received endoprosthetic surgery at our institution. Also, we aimed to assess the portion related to allergic reactions in endoprosthetic revisions and to follow-up those patients after allergic reaction related revisions. METHODS We selected patients with a pre-operative known sensitisation to chromium, cobalt, nickel, or a cement component for a post-operative allergic reaction. All patients who received revision surgery because of a potential allergic reaction were followed up post revision surgery. RESULTS Eight hundred fifty-five patients were pre-operative known to have a sensitisation to chromium, cobalt, nickel, or a cement component. Six hundred eighty-two patients (79.8 %) received a primary arthroplasty, and 173 patients (20.2 %) received a revision surgery. Seventeen patients (2.0 %) were revised because of allergic reactions. Allergic reactions were the cause for approximately 0.2 % of all endoprosthetic revisions and for 9.8 % of revisions in patients with sensitisation to one of the reviewed components. Potential allergens were strictly avoided in the replaced prosthesis. Outcome scores improved post-operatively. CONCLUSIONS The allergic patient should be thoroughly informed about potential reactions resulting from implant choice. Our study can serve as risk assessments by quantifying the incidence of allergic reactions due to endoprosthetic treatment.
Collapse
|
26
|
DKG-Stellungnahme zur Epikutantestung von Metalllegierungsplättchen bei Verdacht auf Metallimplantat-Unverträglichkeit. DER ORTHOPADE 2015; 44:905-8. [DOI: 10.1007/s00132-015-3150-8] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
|
27
|
Thomas P, Geier J, Dickel H, Diepgen T, Hillen U, Kreft B, Schnuch A, Szliska C, Mahler V. DKG-Stellungnahme zur Epikutantestung von Metalllegierungsplättchen bei Verdacht auf Metallimplantat-Unverträglichkeit. J Dtsch Dermatol Ges 2015; 13:1001-5. [DOI: 10.1111/ddg.30_12773] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Peter Thomas
- Klinik und Poliklinik für Dermatologie und Allergologie der Ludwig- Maximilians-Universität München
| | - Johannes Geier
- Informationsverbund Dermatologischer Kliniken (IVDK); Institut an der Universität Göttingen
| | - Heinrich Dickel
- Klinik für Dermatologie, Venerologie und Allergologie; St. Josef-Hospital, Ruhr-Universität Bochum
| | - Thomas Diepgen
- Klinische Sozialmedizin; Universitätsklinikum Heidelberg
| | - Uwe Hillen
- Klinik für Dermatologie; Universitätsklinikum Essen
| | - Burkhard Kreft
- Universitätsklinik und Poliklinik für Dermatologie und Venerologie; Universitätsklinikum Halle (Saale) der Martin-Luther-Universität Halle-Wittenberg; Halle Saale
| | - Axel Schnuch
- Informationsverbund Dermatologischer Kliniken (IVDK); Institut an der Universität Göttingen
| | | | - Vera Mahler
- Hautklinik, Universitätsklinikum Erlangen; Friedrich-Alexander-wUniversität Erlangen
| |
Collapse
|
28
|
Thomas P, Geier J, Dickel H, Diepgen T, Hillen U, Kreft B, Schnuch A, Szliska C, Mahler V. DKG statement on the use of metal alloy discs for patch testing in suspected intolerance to metal implants. J Dtsch Dermatol Ges 2015; 13:1001-4. [DOI: 10.1111/ddg.12773] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Peter Thomas
- Department of Dermatology and Allergology of the Ludwig-Maximilians; University Munich; Germany
| | - Johannes Geier
- Information Network of Departments of Dermatology (IVDK); Institute at the University of Göttingen; Germany
| | - Heinrich Dickel
- Department of Dermatology, Venereology, and Allergology; St.-Josef-Hospital, Ruhr-University Bochum; Germany
| | - Thomas Diepgen
- Clinical Social Medicine; University Hospital Heidelberg; Germany
| | - Uwe Hillen
- Department of Dermatology; University Hospital Essen; Germany
| | - Burkhard Kreft
- Department of Dermatology and Venereology; University Hospital Halle (Saale) of the Martin-Luther University Halle-Wittenberg, Halle (Saale); Germany
| | - Axel Schnuch
- Information Network of Departments of Dermatology (IVDK); Institute at the University of Göttingen; Germany
| | | | - Vera Mahler
- Department of Dermatology; University Hospital Erlangen, Friedrich- Alexander University Erlangen; Germany
| |
Collapse
|
29
|
Morwood MP, Garrigues GE. Shoulder arthroplasty in the patient with metal hypersensitivity. J Shoulder Elbow Surg 2015; 24:1156-64. [PMID: 25799922 DOI: 10.1016/j.jse.2015.01.015] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/04/2014] [Revised: 01/19/2015] [Accepted: 01/21/2015] [Indexed: 02/07/2023]
Abstract
The in vivo effects of metal hypersensitivity remain a topic of much debate. At the core of this debate is the possible, although still hotly contested, link between metal hypersensitivity and poorly functioning or failing implants. There are multiple studies on this topic in the hip and knee arthroplasty literature, but the applicability of this experience to shoulder arthroplasty remains unclear. Although how often metal hypersensitivity affects shoulder arthroplasty patients remains uncertain, a multitude of case reports have implicated metallic implants as a source of local and systemic allergic reactions. We recommend a cautious approach to patients with a history of metal hypersensitivity, including a careful evaluation of suspected metal hypersensitivities in all patients undergoing shoulder arthroplasty. If available, we recommend a metallic implant with low to no nickel content in patients with metal hypersensitivity. Given the large and increasing, number of total shoulder arthroplasty procedures and the high percentage of the population having a known or suspected metal hypersensitivity, this review is intended to guide and educate the shoulder surgeon in the evaluation and treatment of this patient population and to point out the areas where evidence-based recommendations are lacking.
Collapse
Affiliation(s)
- Michael P Morwood
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, NC, USA.
| | - Grant E Garrigues
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, NC, USA
| |
Collapse
|
30
|
[Histopathological particle algorithm. Particle identification in the synovia and the SLIM]. Z Rheumatol 2015; 73:639-49. [PMID: 24821089 DOI: 10.1007/s00393-013-1315-6] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
BACKGROUND In the histopathological diagnostics of synovitis and the synovium-like interface membrane (SLIM) the identification of crystals and crystal-like deposits and the associated inflammatory reactions play an important role. The multitude of endogenous crystals, the range of implant materials and material combinations, and the variability in the formation process of different particles explain the high morphological particle heterogeneity which complicates the diagnostic identification of diagnostic particles. STUDY DESIGN AND METHODS A simple histopathological particle algorithm has been designed which allows methodological particle identification based on (1) conventional transmitted light microscopy with a guide to particle size, shape and color, (2) optical polarization criteria and (3) enzyme histochemical properties (oil red staining and Prussian blue reaction). These methods, the importance for particle identification and the differential diagnostics from non-prosthetic materials are summarized in the so-called histopathological particle algorithm. RESULTS A total of 35 cases of synovitis and SLIM were analyzed and validated according to these criteria. Based on these criteria and a dichotomous differentiation the complete spectrum of particles in the SLIM and synovia can be defined histopathologically. CONCLUSION For histopathological diagnosis a particle score for synovitis and SLIM is recommended to evaluate (1) the predominant type of prothetic wear debris with differentiation between microparticles, and macroparticles, (2) the presence of non-prosthesis material particles and (3) the quantification of particle-association necrosis and lymphocytosis. An open, continuously updated web-based particle algorithm would be helpful to address the issue of particle heterogeneity and include all new particle materials generated in a rapidly changing field.
Collapse
|
31
|
Patients with intolerance reactions to total knee replacement: combined assessment of allergy diagnostics, periprosthetic histology, and peri-implant cytokine expression pattern. BIOMED RESEARCH INTERNATIONAL 2015; 2015:910156. [PMID: 25866822 PMCID: PMC4383474 DOI: 10.1155/2015/910156] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/04/2014] [Accepted: 09/08/2014] [Indexed: 12/21/2022]
Abstract
We performed a combined approach to identify suspected allergy to knee arthroplasty (TKR): patch test (PT), lymphocyte transformation test (LTT), histopathology (overall grading; T- and B-lymphocytes, macrophages, and neutrophils), and semiquantitative Real-time-PCR-based periprosthetic inflammatory mediator analysis (IFNγ, TNFα, IL1-β, IL-2, IL-6, IL-8, IL-10, IL17, and TGFβ). We analyzed 25 TKR patients with yet unexplained complications like pain, effusion, and reduced range of motion. They consisted of 20 patients with proven metal sensitization (11 with PT reactions; 9 with only LTT reactivity). Control specimens were from 5 complicated TKR patients without metal sensitization, 12 OA patients before arthroplasty, and 8 PT patients without arthroplasty. Lymphocytic infiltrates were seen and fibrotic (Type IV membrane) tissue response was most frequent in the metal sensitive patients, for example, in 81% of the PT positive patients. The latter also had marked periprosthetic IFNγ expression. 8/9 patients with revision surgery using Ti-coated/oxinium based implants reported symptom relief. Our findings demonstrate that combining allergy diagnostics with histopathology and periprosthetic cytokine assessment could allow us to design better diagnostic strategies.
Collapse
|
32
|
[Revision arthroplasty : Histopathological diagnostics in periprosthetic joint infections]. DER ORTHOPADE 2015; 44:349-56. [PMID: 25731144 DOI: 10.1007/s00132-015-3083-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
BACKGROUND Histopathological differences in synovia and synovial-like interface membrane (SLIM) patterns can be used to differentiate periprosthetic particle-induced reactions, bacterial infections (bacterial synovitis and osteomyelitis), mechanical-induced tissue alterations, adverse reactions to implant material, and arthrofibrosis (SLIM consensus classification). AIM Because of differences in treatment the diagnosis of a bacterial implant infection is very important. Histopathological tests and scoring systems are important diagnostic tools in identifying deep implant infections in patients with unclear clinical history as well as radiographic and laboratory studies. RESULTS Modern enzyme PCR-based methods, histochemical- and immune-histopathological techniques (CD3,CD15, CD68) are useful in identifying specific and nonspecific infections, as well as differentiating postsurgical changes from recurrent infections in patients with a spacer. In all histopathological scoring systems for bacterial infection, quantifying the number of neutrophil granulocytes in a defined number of high power fields is crucial. DISCUSSION Neutrophil granulocytes can be detected through histochemical methods and more specifically by immune-histopathological techniques and by various quantification systems (histopathological scores) leading to the diagnosis of bacterial peri-implant infection. One important function of histopathology, apart from diagnosing infection, is to rule out other mechanisms of implant failure, such as tumor infiltrations, particle-induced reactions, and adverse reactions to implant materials.
Collapse
|
33
|
Thomas P, Summer B. Diagnosis and management of patients with allergy to metal implants. Expert Rev Clin Immunol 2015; 11:501-9. [DOI: 10.1586/1744666x.2015.1016501] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
34
|
|
35
|
Stiehler M, Zobel F, Hannemann F, Schmitt J, Lützner J, Kirschner S, Günther KP, Hartmann A. [Complications of metal-on-metal tribological pairing]. DER ORTHOPADE 2014; 43:79-91. [PMID: 24356820 DOI: 10.1007/s00132-013-2131-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
BACKGROUND Metal-on-metal (MoM) tribological pairing results in less volumetric abrasion than pairing with the conventionally used polyethylene and is associated with a lower risk of material failure compared to other hard-hard pairings. An increased frequency of problem cases in recent years has led to a great increase in uncertainty. Against this background in this article the current aspects of epidemiology, etiology, diagnostics and treatment of complications in MoM hip joint endoprostheses will be discussed. EPIDEMIOLOGY AND ETIOLOGY Based on the results from national endoprosthesis registers and selected clinical studies an evaluation of the rate of local complications from MoM tribological pairings was undertaken. A differentiation was made between MoM pairings in pedicled small head prostheses (≤ 32 mm), large head (> 32 mm) and surface replacement (OFE) endoprostheses. Each year MoM endoprostheses release on average 10(12)-10(14) cobalt (Co) and chromium (Cr) nanoparticles per patient. This release of metal ions and particles can lead to a variety of tissue reactions. DIAGNOSTICS A differentiation must be made between regular routine diagnostics within the framework of implant follow-up screening and specific investigations due to the occurrence of complaints. The diagnostics for patients treated with MoM hip endoprostheses consists of a standardized step-wise approach considering possible differential diagnoses and the utilization of modern laboratory chemical and radiological methods. When problems occur, a differentiation should preferentially be made between complaints not caused by metal and mechanical problems (e.g. prosthesis loosening and impingement) and symptoms due to periprosthetic infections. THERAPY OF COMPLICATIONS The normal standards for hip endoprosthetics are also valid for periprosthetic infections, fractures and other general complications. Specific measures are, however, necessary for complications due to metal-specific risks.
Collapse
Affiliation(s)
- M Stiehler
- UniversitätsCentrum für Orthopädie und Unfallchirurgie, Klinik für Orthopädie, Universitätsklinikum Carl Gustav Carus, TU Dresden, Fetscherstr. 74, 01307, Dresden, Deutschland
| | | | | | | | | | | | | | | |
Collapse
|
36
|
Thomas P. Clinical and diagnostic challenges of metal implant allergy using the example of orthopaedic surgical implants: Part 15 of the Series Molecular Allergology. ACTA ACUST UNITED AC 2014; 23:179-185. [PMID: 26120529 PMCID: PMC4479460 DOI: 10.1007/s40629-014-0023-3] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2014] [Accepted: 05/29/2014] [Indexed: 11/25/2022]
Abstract
The focus of this review are allergic reactions to orthopaedic-surgical metal implants. The spectrum of metal implant associated potential allergic reactions encompasses eczema, impaired wound and fracture healing, infection-mimicking reactions, effusions, pain and loosening. Nickel, cobalt and chromium seem to be the predominant eliciting allergens. Despite the growing number of respective publications the topic „metal implant allergy“ remains a diagnostic challenge. Initially, differential diagnoses should always be excluded in cooperation with surgery collegues. It is recommended to perform a combined evaluation of medical history, clinical findings, patch testing and histology. The lymphocyte transformation test (LTT) can indicate metal sensitization, but it needs careful interpretation. Allergists can provide a substantial contribution to this interdisciplinary topic.
Collapse
Affiliation(s)
- Peter Thomas
- Department of Dermatology and Allergology, Ludwig-Maximilians-University Munich, Frauenlobstraße 9-11, 80337 Munich, Germany
| |
Collapse
|
37
|
Thomas P. Klinische und diagnostische Herausforderungen der Metallimplantatallergie am Beispiel orthopädisch-chirurgischer Implantate. ALLERGO JOURNAL 2014. [DOI: 10.1007/s15007-014-0650-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
38
|
Kulichová D, Gehrke T, Kendoff D, Summer B, Parvizi J, Thomas P. Metal Hypersensitivity Mimicking Periprosthetic Erysipelas-Like Infection: A Case Report. JBJS Case Connect 2014; 4:e65. [PMID: 29252586 DOI: 10.2106/jbjs.cc.m.00154] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Affiliation(s)
- Daniela Kulichová
- Department of Dermatology and Allergology, Ludwig-Maximilian University, Frauenlobstrasse 9-11, Munich, 80337, Germany.
| | - Thorsten Gehrke
- Department of Orthopaedic Surgery, ENDO-Klinik, Holstenstraße 2, Hamburg, 22767, Germany
| | - Daniel Kendoff
- Department of Orthopaedic Surgery, ENDO-Klinik, Holstenstraße 2, Hamburg, 22767, Germany
| | - Burkhard Summer
- Department of Dermatology and Allergology, Ludwig-Maximilian University, Frauenlobstrasse 9-11, Munich, 80337, Germany.
| | - Javad Parvizi
- Rothman Institute of Orthopaedics, Thomas Jefferson University Hospitals, 925 Chestnut Street, Philadelphia, PA 19107
| | - Peter Thomas
- Department of Dermatology and Allergology, Ludwig-Maximilian University, Frauenlobstrasse 9-11, Munich, 80337, Germany.
| |
Collapse
|
39
|
Metal hypersensitivity reactions to implants: opinions and practices of patch testing dermatologists. Dermatitis 2014; 24:313-20. [PMID: 24201465 DOI: 10.1097/der.0b013e3182a67d90] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
BACKGROUND Cutaneous metal hypersensitivity reactions (MHR) are common but rare with implanted devices. OBJECTIVES This study aimed to characterize the opinions of dermatologists who are actively evaluating/advising patients with MHR. METHODS A questionnaire was distributed to all individuals who attended the European Society of Contact Dermatitis (ESCD) 2012 and the American Contact Dermatitis Society 2013 meetings. RESULTS A total of 119 individuals responded with a participation rates of 10% (ESCD) and 32% (American Contact Dermatitis Society). Ninety-six percent of the respondents evaluate MHR and 91% were attending physicians. Orthopedic and dental devices were common problems compared with cardiovascular devices. Patch testing is the top choice for evaluating MHR. Lymphocyte transformation and intradermal tests are rarely used. Eighty-two percent of the respondents evaluate plastic/glue components in symptomatic patients postimplant. Most dermatologists use a tray specifically for joint allergy or a history-based custom array of allergens. Those patients with a strong clinical history of metal allergy should be evaluated before metal implantation (54%), whereas others forgo evaluation and recommend a titanium implant based on history alone (38%). Diagnostic criteria for postimplant reactions were evaluated. Eight percent of the respondents felt that no evaluation was necessary, with ESCD respondents being significantly more likely to not recommend evaluation (P = 0.001). CONCLUSIONS Metal hypersensitivity reactions consultation requests are common for preimplant and postimplant issues. Patch testing is currently the best test for MHR.
Collapse
|
40
|
|
41
|
Abstract
In a representative survey among members of the working group for joint replacement (AE) in Germany (86.7% response) it was found that 0.6% of patients with total knee arthroplasty (TKA) and 1.2% of patients with total hip arthroplasty (THA) may have a problem due to hypersensitivity to nickel or cobalt after implantation. Only one third of them may need revision surgery. Although patients with hypersensitivity are rare 84% of surgeons would prefer to use a specially coated allergy implant for knee arthroplasty patients. However, no long term results and few data on the topic of allergies and joint arthroplasty are available for these implants so that this has to be critically discussed with patients. Before a revision is performed it is recommended to perform knee arthroscopy to obtain tissue for microbiological and histopathological investigations. The second part of this questionnaire will look at the special question of how to deal with allergy patients based on constructed case examples.
Collapse
|
42
|
Thomas P, Stauner K, Schraml A, Mahler V, Banke IJ, Gollwitzer H, Burgkart R, Prodinger PM, Schneider S, Pritschet M, Mazoochian F, Schopf C, Steinmann A, Summer B. [Characteristics of 200 patients with suspected implant allergy compared to 100 symptom-free arthroplasty patients]. DER ORTHOPADE 2014; 42:607-13. [PMID: 23907451 DOI: 10.1007/s00132-012-2038-0] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
BACKGROUND Data on implant allergies are incomplete; therefore, we compared the data on allergy history, patch test (PT) and lymphocyte transformation test (LTT) results in a patient series from the Munich implant allergy outpatient department with symptom-free arthroplasty patients. PATIENTS AND METHODS In this study 200 arthroplasty patients with complaints involving the prosthesis (130 female, 187 knee and 13 hip prostheses) and in parallel 100 symptom-free patients (75 female, 47 knee and 53 hip prostheses) were investigated. A questionnaire-aided history including implant type, cementing, intolerance of dental materials, atopy, cutaneous metal intolerance (CMI) and PT, including a standard series with Ni, Co, Cr, seven bone cement components, including gentamicin and benzoyl peroxide and LTT for Ni, Co and Cr. RESULTS In the knee arthroplasty patients with complaints 9.1% showed dental material intolerance, 23.5% atopy, 25.7% CMI, 18.2% metal allergies, 7.4% gentamicin allergy and 27.8% positive metal LTT (mostly to Ni). In symptom-free patients 0% showed dental material intolerance, 19.1% atopy, 12.8% CMI, 12.8% metal allergy, 0% gentamicin allergy and 17% positive metal LTT. CONCLUSIONS Characteristics of the patients with complaints were increased intolerance of dental materials, higher rates of atopy, CMI, metal and gentamicin allergy and LTT reactivity.
Collapse
Affiliation(s)
- P Thomas
- Klinik und Poliklinik für Dermatologie und Allergologie, Klinikum der Ludwig-Maximilians-Universität München, Frauenlobstr. 9-11, 80337, München, Deutschland.
| | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
43
|
Lützner J, Hartmann A, Dinnebier G, Spornraft-Ragaller P, Hamann C, Kirschner S. Metal hypersensitivity and metal ion levels in patients with coated or uncoated total knee arthroplasty: a randomised controlled study. INTERNATIONAL ORTHOPAEDICS 2013; 37:1925-31. [PMID: 23860793 PMCID: PMC3779567 DOI: 10.1007/s00264-013-2010-6] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/24/2013] [Accepted: 06/24/2013] [Indexed: 12/23/2022]
Abstract
PURPOSE Metal ion release by orthopaedic implants may cause local and systemic effects and induce hypersensitivity reactions. Coated implants have been developed to prevent or reduce these effects. This study was initiated to investigate the safety of a novel coating for total knee arthroplasty (TKA) implants. METHODS A total of 120 patients undergoing primary TKA with no history of hypersensitivity and no other metal implant were randomised to receive either a coated or uncoated implant. Chromium (Cr), cobalt (Co), molybdenum (Mb) and nickel (Ni) hypersensitivity patch testing and plasma ion concentrations were evaluated pre-operatively and one year post-operatively. RESULTS At the one year follow-up both groups demonstrated significant improvement in knee function and quality of life. One new weakly positive reaction to Co in the TKA group with coated implant and two doubtful skin reactions to Ni (one in each group) were noted. Even with sensitisation to implant materials no skin reactions were observed. Plasma metal ion concentrations did not increase and were not elevated at the one year follow-up in either group. CONCLUSIONS Sensitisation after TKA was rare and had no influence on clinical results. TKA with coated implant and standard TKA demonstrated no plasma metal ion elevation.
Collapse
Affiliation(s)
- Jörg Lützner
- Department of Orthopaedic Surgery, University Hospital Carl Gustav Carus, Medical Faculty of the Technical University of Dresden, Fetscherstr. 74, 01307, Dresden, Germany,
| | | | | | | | | | | |
Collapse
|
44
|
Third-body abrasive wear of tibial polyethylene inserts combined with metallic and ceramic femoral components in a knee simulator study. Int J Artif Organs 2013; 36:47-55. [PMID: 23335379 DOI: 10.5301/ijao.5000189] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/25/2012] [Indexed: 11/20/2022]
Abstract
AIM Total knee arthroplasties have reached a high grade of quality and safety, but most often fail because of aseptic implant loosening caused by polyethylene wear debris. Wear is generated at the articulating surfaces, e.g. caused by third-body particles. The objective of this experimental study was to determine the wear of tibial polyethylene inserts combined with metallic and ceramic femoral components under third-body wear conditions initiated by bone cement particles.
METHODS AND MATERIALS Wear testing using a cemented unconstrained bicondylar knee endoprosthesis (Multigen Plus CR knee system) was performed in a knee wear simulator. Tibial polyethylene inserts were combined with the identical femoral component design, but made of two different materials (cobalt-chromium and ceramic). Bone cement debris including zirconium oxide particles was added every 500,000 cycles between the articulating surfaces. After 5 million load cycles, the amount of wear was determined gravimetrically and compared with results from standard wear test conditions. The surfaces of tibial inserts were also analyzed.
RESULTS The average gravimetrical wear of the tibial polyethylene inserts in combination with
cobalt-chromium and ceramic femoral components under third-body wear conditions amounted to 31.88 ± 4.53 mg and 13.06 ± 1.88 mg after 5 million cycles, respectively, and was higher than under standard wear test conditions in both cases.
CONCLUSIONS The wear simulator test demonstrates that wear of polyethylene inserts under third-body wear conditions, in combination with ceramic femoral components, was significantly lower than with metallic femoral components.
Collapse
|
45
|
Histopathologische Differenzialdiagnostik bei gelenkimplantatallergischen Fragestellungen. DER ORTHOPADE 2013; 42:614-21. [DOI: 10.1007/s00132-012-2034-4] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|
46
|
Allergiediagnostik bei Verdacht auf Metallimplantatunverträglichkeit. DER ORTHOPADE 2013; 42:602-6. [DOI: 10.1007/s00132-012-2033-5] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
47
|
Biotribology of a new bearing material combination in a rotating hinge knee articulation. Acta Biomater 2013; 9:7054-63. [PMID: 23485855 DOI: 10.1016/j.actbio.2013.02.030] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2012] [Revised: 01/25/2013] [Accepted: 02/16/2013] [Indexed: 12/13/2022]
Abstract
The objective of the present study was to evaluate the biotribological behaviour, in terms of wear and particle release, of bushings and flanges made of carbon fibre reinforced poly-ether-ether-ketone (CFR-PEEK) in articulation with a zirconium nitride (ZrN) multilayer surface coating in a rotating hinge knee system. For the bushings of the rotational and flexion axles and the medial and lateral flanges, a CFR-PEEK with 30% polyacrylonitrile fibre content was used in a new bearing combination with ZrN. In vitro wear simulation was performed for patients with metal ion hypersensitivity, using a new rotating hinge knee design with a ZrN surface articulation in comparison with the clinically established cobalt-chromium version. For the bushings and flanges made of CFR-PEEK subjected to wear simulation, the volumetric wear rates were 2.3±0.48mm(3)million(-1) cycles in articulation to cobalt-chromium as reference and 0.21±0.02mm(3)million(-1) cycles in the coupling with ZrN, a 10.9-fold decrease. The released CFR-PEEK particles were comparable in size and shape for the coupling to cobalt-chromium and ZrN with most of the particles in a size range between 0.1 and 2μm. The study reveals comparable low wear and no macroscopic surface fatigue in a new rotating hinge knee design with highly congruent flanges and axles bushings made of CFR-PEEK articulating to a ZrN multilayer surface coating. Favourable wear behaviour of the newly introduced CFR-PEEK/ZrN coupling in comparison with the clinically established CFR-PEEK/cobalt-chromium articulation was found.
Collapse
|
48
|
Commentary on Crawford, et al, The Role of Patch Testing in the Evaluation of Orthopedic Implant-Related Adverse Effects. Dermatitis 2013; 24:108-11. [DOI: 10.1097/der.0b013e3182979722] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
49
|
|
50
|
Krenn V, Ruppert M, Knöß P, Kendoff D, Poremba C, Thomsen M, Skutek M, Hassenpflug J, Ascherl R, Krukemeyer M, Matziolis G, Thomas P, Gehrke T. Synovialitis vom arthrofibrotischen Typ. Z Rheumatol 2012; 72:270-8. [DOI: 10.1007/s00393-012-1076-7] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|