1
|
Dong M, Fan H, Yang D, Sun X, Yan C, Feng Y. Comparison of spatiotemporal, kinematic, and kinetic gait characteristics in total and unicompartmental knee arthroplasty during level walking: A systematic review and meta-analysis. Gait Posture 2023; 104:58-69. [PMID: 37321113 DOI: 10.1016/j.gaitpost.2023.06.005] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/29/2022] [Revised: 03/26/2023] [Accepted: 06/05/2023] [Indexed: 06/17/2023]
Abstract
PURPOSE This meta-analysis was performed to compare the spatiotemporal, kinematic, and kinetic gait characteristics during level walking between total knee arthroplasty (TKA) and unicompartmental knee arthroplasty (UKA). METHODS An electronic database literature search was performed to screen clinical trials which were included the studies evaluating not only spatiotemporal, kinematic, and kinetic gait parameters, but also knee range of motion and knee score (Knee Society Score and Oxford Knee Score, i.e., KSS and OKS). The data analysis was performed using statistical software Stata 14.0 and Review Manager 5.4. RESULTS Thirteen studies (369 knees) that met the criteria were eventually included in this meta-analysis. The results revealed significant differences between UKA and TKA with regard to walking speed (P = 0.04), stride length (P = 0.02), maximum knee flexion at loading (P = 0.001), the 1st peak of vert-GRF (P = 0.006), the 1st valley of vert-GRF (P = 0.007), knee internal rotational moment (P = 0.04), knee extension (P < 0.00001), and KSS Function score (P = 0.05). In contrast, there were no statistical differences in the remaining spatiotemporal, kinematic, and kinetic gait parameters. CONCLUSION Medial UKA design is superior to TKA design with regard to walking speed, stride length, maximum knee flexion at loading, the 1st peak and the 1st valley of vert-GRF, knee internal rotational moment, knee extension, and KSS Function score. And it could provide a stronger basis for physicians to make clinical decisions.
Collapse
Affiliation(s)
- Mingjie Dong
- Department of Orthopaedics, the Second Clinical Medical College of Shanxi Medical University, 030000 Taiyuan, China
| | - Hao Fan
- Department of Orthopaedics, the Second Clinical Medical College of Shanxi Medical University, 030000 Taiyuan, China
| | - Dinglong Yang
- Department of Orthopaedics, the Second Clinical Medical College of Shanxi Medical University, 030000 Taiyuan, China
| | - Xiaoyu Sun
- Department of Orthopaedics, the Second Clinical Medical College of Shanxi Medical University, 030000 Taiyuan, China
| | - Chaochao Yan
- Department of Orthopaedics, the Second Clinical Medical College of Shanxi Medical University, 030000 Taiyuan, China
| | - Yi Feng
- Department of Orthopaedics, the Second Hospital of Shanxi Medical University, 030000 Taiyuan, China.
| |
Collapse
|
2
|
Güngör HR, Bayrak G, Zora H, Şavkın R, Büker N. Foot and/or ankle problems following limb alignment changes in uni-compartmental knee arthroplasty. JOURNAL OF ORTHOPAEDICS, TRAUMA AND REHABILITATION 2023. [DOI: 10.1177/22104917221101410] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
Objective Foot and/or ankle (F/A) problems may be encountered in medial uni-compartmental knee (UKA) patients postoperatively due to the limb alignment changes and alterations in weight bearing of F/A. This study aimed to evaluate the risk factors and the incidence of foot and ankle (F/A) problems in (UKA) arthroplasty patients. Methods Patients who underwent UKA between 2016 and 2019 in our clinic were evaluated and the presence of F/A problems was recorded. Radiologic evaluations included hip knee ankle angle (HKA), medial proximal tibial angle, posterior tibial slope angle, talar tilt angle, talar inclination, talar dome to mechanical axis (TDMA), and talocrural angle (TCA) measured on preoperative and follow-up long-leg standing radiographs. The range of motion, Q angles, and muscle strengths were measured. Visual analog scale, physical performance limitations, and patient-reported activity limitations were evaluated for all patients. Patients with reported F/A problems were additionally evaluated with Foot Functional Index. Results Forty-four patients (38 female, 6 male; mean age 58.66 ± 8.6 years; mean BMI 31.30 ± 3.81, mean follow-up period 34.22 ± 18.95 months) were included in the study. There were 13 patients (29.5%) with reported F/A problems. Postoperative comparison of patients with and without F/A problems showed statistically significant differences in only WOMAC and SF12 physical health sub-scores ( p = 0.002, p = 0.003, respectively). There was no significant postoperative change in TDMA in patients with F/A problems ( p > 0.05) in contrast to patients without F/A problems ( p = 0.006). There was no statistically significant difference in preoperative TCA measurements between groups ( p = 0.79). Comparison of knee and ankle radiologic measurements between groups demonstrated significant difference only in postoperative HKA measurements (−2.82 ± 2.53 vs. −0.80 ± 3.12, p = 0.033). Conclusion F/A problems adversely affecting the functional status were frequent in our cohort of UKA patients. Postoperative residual varus deformity may be a risk factor for this. Therefore, if slight varus alignment is aimed at UKA patients, preoperative F/A status should be evaluated.
Collapse
Affiliation(s)
- Harun Reşit Güngör
- Orthopedics and Traumatology Department, Pamukkale University Medical Faculty, Denizli, Turkey
| | - Gökhan Bayrak
- Physiotherapy and Rehabilitation Department of Faculty of Health Sciences, Muş Alparslan University, Muş, Turkey
| | - Hakan Zora
- Department of Orthopedics and Traumatology, Artvin State Hospital, Artvin, Turkey
| | - Raziye Şavkın
- Faculty of Physiotherapy and Rehabilitation, Pamukkale University, Denizli, Turkey
| | - Nihal Büker
- Faculty of Physiotherapy and Rehabilitation, Pamukkale University, Denizli, Turkey
| |
Collapse
|
3
|
Psaltos DJ, Mamashli F, Adamusiak T, Demanuele C, Santamaria M, Czech MD. Wearable-Based Stair Climb Power Estimation and Activity Classification. SENSORS (BASEL, SWITZERLAND) 2022; 22:6600. [PMID: 36081058 PMCID: PMC9459813 DOI: 10.3390/s22176600] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/14/2022] [Revised: 08/25/2022] [Accepted: 08/26/2022] [Indexed: 06/15/2023]
Abstract
Stair climb power (SCP) is a clinical measure of leg muscular function assessed in-clinic via the Stair Climb Power Test (SCPT). This method is subject to human error and cannot provide continuous remote monitoring. Continuous monitoring using wearable sensors may provide a more comprehensive assessment of lower-limb muscular function. In this work, we propose an algorithm to classify stair climbing periods and estimate SCP from a lower-back worn accelerometer, which strongly agrees with the clinical standard (r = 0.92, p < 0.001; ICC = 0.90, [0.82, 0.94]). Data were collected in-lab from healthy adults (n = 65) performing the four-step SCPT and a walking assessment while instrumented (accelerometer + gyroscope), which allowed us to investigate tradeoffs between sensor modalities. Using two classifiers, we were able to identify periods of stair ascent with >89% accuracy [sensitivity = >0.89, specificity = >0.90] using two ensemble machine learning algorithms, trained on accelerometer signal features. Minimal changes in model performances were observed using the gyroscope alone (±0−6% accuracy) versus the accelerometer model. While we observed a slight increase in accuracy when combining gyroscope and accelerometer (about +3−6% accuracy), this is tolerable to preserve battery life in the at-home environment. This work is impactful as it shows potential for an accelerometer-based at-home assessment of SCP.
Collapse
|
4
|
Haffar A, Krueger CA, Marullo M, Banerjee S, Dobelle E, Argenson JN, Sprenzel JF, Berger RA, Romagnoli S, Lonner JH. Staged BiCompartmental Knee Arthroplasty has Greater Functional Improvement, but Equivalent Midterm Survivorship, as Revision TKA for Progressive Osteoarthritis After Partial Knee Arthroplasty. J Arthroplasty 2022; 37:1260-1265. [PMID: 35227809 DOI: 10.1016/j.arth.2022.02.084] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/10/2021] [Revised: 02/11/2022] [Accepted: 02/19/2022] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Progressive arthritis in the unresurfaced compartments of the knee is one failure mode after partial knee arthroplasty (PKA). While progressive arthritis after PKA is typically treated with revision to TKA (rTKA), staged bicompartmental knee arthroplasty (sBiKA) -the addition of another PKA - is an alternative. This study compared outcomes of sBiKA and rTKA for progressive arthritis after PKA. METHODS A retrospective comparative study of non-consecutive cases at four institutions were performed in patients with an intact PKA, without loosening or wear, who underwent sBiKA (n = 27) or rTKA (n = 30), for progressive osteoarthritis. Outcomes studied were new Knee Society Function and Objective Scores (KSSF, KSSO), KOOS, Jr., ROM, operative times, length of stay, complication rates and the need for reoperations. RESULTS Mean time to conversion was 7.4 ± 6 years for sBiKA and 9.7 ± 8 for rTKA, P = .178. Patient demographics and pre-operative outcomes were similar among cohorts. At an average of 5.7 ± 3 (sBiKA) and 3.2 ± 2 years (rTKA), KOOS, Jr. significantly improved, P < .001, by an equivalent amount. Post-operative KSSO and KSSF were significantly higher in the sBiKA cohort, respectively, (90.4 ± 10 vs 72.1 ± 20, P < .001) and (80.3 ± 18 vs 67.1 ± 19, P = .011). sBiKA patients had significantly greater improvement in KSSO (30.7 ± 33 vs 5.2 ± 18, P = .003). One sBiKA patient underwent reoperation for continued pain. CONCLUSION SBiKA has equivalent survivorship, but greater improvement in functional outcomes as rTKA at short to midterm follow-up. Given the shorter operative times and length of stay, sBiKA is a safe and cost-effective alternative to rTKA for progressive osteoarthritis following PKA. Nevertheless, further follow-up is necessary to determine whether sBiKA is a durable option.
Collapse
Affiliation(s)
- Amer Haffar
- Rothman Orthopaedic Institute at Thomas Jefferson University, Philadelphia, PA
| | - Chad A Krueger
- Rothman Orthopaedic Institute at Thomas Jefferson University, Philadelphia, PA
| | - Matteo Marullo
- Joint Replacement Department, IRCCS Istituto Ortopedico Galeazzi, Milan, Italy
| | - Samik Banerjee
- Rothman Orthopaedic Institute at Thomas Jefferson University, Philadelphia, PA
| | - Emile Dobelle
- Department of Orthopedics and Traumatology, Institute for Locomotion, St. Marguerite Hospital, Marseille, France
| | - Jean N Argenson
- Department of Orthopedics and Traumatology, Institute for Locomotion, St. Marguerite Hospital, Marseille, France
| | - Jenny F Sprenzel
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL
| | - Richard A Berger
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL
| | - Sergio Romagnoli
- Joint Replacement Department, IRCCS Istituto Ortopedico Galeazzi, Milan, Italy
| | - Jess H Lonner
- Rothman Orthopaedic Institute at Thomas Jefferson University, Philadelphia, PA
| |
Collapse
|
5
|
Derreveaux V, Schmidt A, Shatrov J, Sappey-Marinier E, Batailler C, Servien E, Lustig S. Combined procedures with unicompartmental knee arthroplasty: High risk of stiffness but promising concept in selected indications. SICOT J 2022; 8:4. [PMID: 35191830 PMCID: PMC8862640 DOI: 10.1051/sicotj/2022002] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/28/2021] [Accepted: 01/07/2022] [Indexed: 11/18/2022] Open
Abstract
Introduction: Unicompartmental knee arthroplasty (UKA) has traditionally been contraindicated in the presence of an ACL deficient knee, bi-compartmental disease, or significant coronal deformity due to concerns regarding increased risk of persisted pain, knee instability, tibial loosening, or progression of osteoarthritis. The aim of this study was to evaluate the outcomes of patients undergoing UKA with an associated surgical procedure in these specific indications. Method: This was a retrospective cohort study of patients undergoing UKA between December 2015 and October 2020. Patients were categorized into groups based on associated procedures: UKA + ACL, UKA + HTO, and bicompartmental arthroplasty. Outcomes were assessed using the Knee Society Score (KSS) knee and function scores and the Forgotten Joint Score. Radiological and complication analysis was performed at the last clinical follow-up. Results: Thirty-two patients (13 men and 19 women) were included. The mean age was 56.2 years ± 11.1 (range, 33–84) with a mean follow-up of 26.3 months ± 15 (7.3–61.1). There was a significant improvement between the pre-and postoperative KSS Knee (+34.3 ± 16.5 [12–69]), Function (+34.3 ± 18.6 [0–75]), and Total scores (+68.5 ± 29.4 [24–129]) (p = 0.001). Seven patients (21.8%) required an arthroscopic arthrolysis for persistent stiffness. Two patients (UKA + PFA and UKA + ACL) underwent revision to TKA. Patient satisfaction was 90%, and mean flexion at last follow-up was 122° ± 6 (120–140). The implant survival rate was 94%. Discussion: This study found performing UKA with an additional procedure to address relative contraindications to the arthroplasty in physically active patients with monocompartmental knee arthritis is an efficient strategy with good results at short-term follow-up. It should be reserved for patients where TKA is likely to have unsatisfactory results, and the patient has been fully counseled regarding the management options. Even if there is a high rate of complications with stiffness requiring a re-intervention, the final results are very satisfying with no impact of the reintervention on the clinical result in the short term.
Collapse
Affiliation(s)
- Vianney Derreveaux
- FIFA Medical Center of Excellence, Orthopaedics Surgery and Sports Medicine Department, Croix-Rousse Hospital, Hospices Civils de Lyon 103 Grande rue de la Croix Rousse 69004 Lyon France
| | - Axel Schmidt
- FIFA Medical Center of Excellence, Orthopaedics Surgery and Sports Medicine Department, Croix-Rousse Hospital, Hospices Civils de Lyon 103 Grande rue de la Croix Rousse 69004 Lyon France
- Corresponding author:
| | - Jobe Shatrov
- Sydney Orthopaedic Research Institute Chatswood Sydney 2067 Australia
- University of Notre Dame Australia Orthopaedic Research Institute Sydney 2007 Australia
- Hornsby and Ku-Ring Hospital Sydney 2077 Australia
| | - Elliot Sappey-Marinier
- FIFA Medical Center of Excellence, Orthopaedics Surgery and Sports Medicine Department, Croix-Rousse Hospital, Hospices Civils de Lyon 103 Grande rue de la Croix Rousse 69004 Lyon France
- Univ Lyon, Claude Bernard Lyon 1 University, IFSTTAR, LBMC UMR_T9406 25 Avenue François Mitterand 69500 Lyon France
| | - Cécile Batailler
- FIFA Medical Center of Excellence, Orthopaedics Surgery and Sports Medicine Department, Croix-Rousse Hospital, Hospices Civils de Lyon 103 Grande rue de la Croix Rousse 69004 Lyon France
- Univ Lyon, Claude Bernard Lyon 1 University, IFSTTAR, LBMC UMR_T9406 25 Avenue François Mitterand 69500 Lyon France
| | - Elvire Servien
- FIFA Medical Center of Excellence, Orthopaedics Surgery and Sports Medicine Department, Croix-Rousse Hospital, Hospices Civils de Lyon 103 Grande rue de la Croix Rousse 69004 Lyon France
- LIBM – EA 7424, Interuniversity Laboratory of Biology of Mobility, Claude Bernard Lyon 1 University 43 boulevard du 11 Novembre 69622 Villeurbanne France
| | - Sébastien Lustig
- FIFA Medical Center of Excellence, Orthopaedics Surgery and Sports Medicine Department, Croix-Rousse Hospital, Hospices Civils de Lyon 103 Grande rue de la Croix Rousse 69004 Lyon France
- Univ Lyon, Claude Bernard Lyon 1 University, IFSTTAR, LBMC UMR_T9406 25 Avenue François Mitterand 69500 Lyon France
| |
Collapse
|
6
|
Eckert JA, Bitsch RG, Sonntag R, Reiner T, Schwarze M, Jaeger S. The primary stability of the femoral component in cemented single and twin peg Oxford unicompartmental knee arthroplasty under adverse conditions. Bone Joint Res 2022; 11:82-90. [PMID: 35124977 PMCID: PMC8882328 DOI: 10.1302/2046-3758.112.bjr-2020-0507.r2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
Aims The cemented Oxford unicompartmental knee arthroplasty (OUKA) features two variants: single and twin peg OUKA. The purpose of this study was to assess the stability of both variants in a worst-case scenario of bone defects and suboptimal cementation. Methods Single and twin pegs were implanted randomly allocated in 12 pairs of human fresh-frozen femora. We generated 5° bone defects at the posterior condyle. Relative movement was simulated using a servohydraulic pulser, and analyzed at 70°/115° knee flexion. Relative movement was surveyed at seven points of measurement on implant and bone, using an optic system. Results At the main fixation zone, the twin peg shows less relative movement at 70°/115°. At the transition zone, relative movements are smaller for the single peg for both angles. The single peg shows higher compression at 70° flexion, whereas the twin peg design shows higher compression at 115°. X-displacement is significantly higher for the single peg at 115°. Conclusion Bony defects should be avoided in OUKA. The twin peg shows high resilience against push-out force and should be preferred over the single peg. Cite this article: Bone Joint Res 2022;11(2):82–90.
Collapse
Affiliation(s)
- Johannes Adrian Eckert
- Laboratory of Biomechanics and Implant Research, Centre for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Heidelberg, Germany.,Orthopaedic University Hospital, Heidelberg University Hospital, Heidelberg, Germany
| | | | - Robert Sonntag
- Laboratory of Biomechanics and Implant Research, Centre for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Heidelberg, Germany
| | - Tobias Reiner
- Laboratory of Biomechanics and Implant Research, Centre for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Heidelberg, Germany.,Orthopaedic University Hospital, Heidelberg University Hospital, Heidelberg, Germany
| | - Martin Schwarze
- Laboratory of Biomechanics and Implant Research, Centre for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Heidelberg, Germany.,Orthopaedic University Hospital, Heidelberg University Hospital, Heidelberg, Germany
| | - Sebastian Jaeger
- Laboratory of Biomechanics and Implant Research, Centre for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Heidelberg, Germany
| |
Collapse
|
7
|
Nishizawa K, Harato K, Morishige Y, Kobayashi S, Niki Y, Nagura T. A comparison of gait characteristics between posterior stabilized total knee and fixed bearing unicompartmental knee arthroplasties. ASIA-PACIFIC JOURNAL OF SPORT MEDICINE ARTHROSCOPY REHABILITATION AND TECHNOLOGY 2020; 22:62-66. [PMID: 32983900 PMCID: PMC7479273 DOI: 10.1016/j.asmart.2020.07.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/30/2020] [Revised: 07/04/2020] [Accepted: 07/27/2020] [Indexed: 11/02/2022]
Abstract
Background/Objective According to previous studies, physiological gait pattern was found in unicompartmental knee arthroplasty (UKA) as compared to total knee arthroplasty (TKA) concerning the gait parameters including gait speed, cadence, and step length. However, little attention had been paid to the detailed kinematic and kinetic differences during gait between TKAs and UKAs. The aim of the present study was to investigate and to clarify the biomechanical differences between posterior stabilized TKAs and fixed bearing UKAs during walking. Methods A total of 28 patients participated in the present study. Fifteen patients who underwent TKA and thirteen patients who underwent UKA were enrolled. Gait analysis was done at an average of 12.9 months after surgery. The subjects performed level walking at a preferred speed. For each subject, three-dimensional kinematic, kinetic and ground reaction force data were recorded as well as clinical data including range of motion at the knee joint and plain radiographs. Differences of knee kinematics or kinetics were compared between TKAs and UKAs using two-tailed Mann Whitney U-test. Results On physical examination, passive range motion was significantly smaller in TKAs than in UKAs, while femorotibial angle on plain radiographs was not significantly different on plain radiographs. In terms of kinematics, TKAs were more flexed at heel contact and less extended in mid-stance phase compared to UKAs in the sagittal plane, and total excursion of TKAs were also smaller than UKAs. Regarding knee kinetics, TKA patients had significantly less peak tibial internal rotation moment in terminal stance phase. In addition, peak knee adduction moment was significantly larger in UKAs than in TKAs, while peak knee flexion moment was not significantly different. Conclusion Posterior stabilized TKAs exhibited less peak tibial internal rotation moment, which is known as pivot shift avoidance gait, in the present study, compared to fixed bearing UKAs. TKAs had similar gait pattern to anterior cruciate ligament deficient knees, compared to UKAs even if patients with TKAs had no subjective pain during walking.
Collapse
Affiliation(s)
- Kohei Nishizawa
- Department of Orthopedic Surgery, Keio University School of Medicine, Tokyo, Japan
| | - Kengo Harato
- Department of Orthopedic Surgery, Keio University School of Medicine, Tokyo, Japan.,Institute for Integrated Sports Medicine, Keio University School of Medicine, Tokyo, Japan
| | - Yutaro Morishige
- Department of Orthopedic Surgery, Keio University School of Medicine, Tokyo, Japan
| | - Shu Kobayashi
- Department of Orthopedic Surgery, Keio University School of Medicine, Tokyo, Japan
| | - Yasuo Niki
- Department of Orthopedic Surgery, Keio University School of Medicine, Tokyo, Japan
| | - Takeo Nagura
- Department of Orthopedic Surgery, Keio University School of Medicine, Tokyo, Japan
| |
Collapse
|
8
|
Kakar RS, Fu YC, Kinsey TL, Brown CN, Mahoney OM, Simpson KJ. Lower limb kinematics of unicompartmental knee arthroplasty individuals during stair ascent. J Orthop 2020; 22:173-178. [PMID: 32419760 DOI: 10.1016/j.jor.2020.04.009] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/02/2020] [Revised: 04/24/2020] [Accepted: 04/25/2020] [Indexed: 10/24/2022] Open
Abstract
Objective Purpose of the study was to compare lower-limb kinematics and interlimb asymmetry during stair ascent in individuals post-medial or lateral unicompartmental knee arthroplasty (UKA). Methods 60 patients (20 medial; 10 lateral) post-UKA and 30 matched healthy controls performed stair ascent. Spatio-temporal, lower-limb kinematics and interlimb asymmetries during stair ascent were compared. Results Medial-UKA group displayed 5° less knee extension of the UKA limb than controls (p = 0.005) and 2° less than the contralateral limb during stance phase. No interlimb asymmetries were found for lateral-UKA. Conclusion Patients post-UKA demonstrate satisfactory lower-limb kinematics and minimal interlimb asymmetry during stair ascent compared to healthy individuals.
Collapse
Affiliation(s)
- Rumit Singh Kakar
- School of Rehabilitation Sciences, Old Dominion University, Norfolk, VA, USA
| | | | | | - Cathleen N Brown
- Department of Kinesiology, Oregon State University, Corvallis, OR, USA
| | - Ormonde M Mahoney
- Athens Orthopedic Clinic, PA, Athens, GA, USA.,Department of Kinesiology, University of Georgia, Athens, GA, USA
| | - Kathy J Simpson
- Department of Kinesiology, University of Georgia, Athens, GA, USA
| |
Collapse
|
9
|
Abstract
SummaryNonlinear articular geometries of biological joints have contributed to highly agile and adaptable human-body motions. However, human–machine interaction could potentially distort natural human motions if the artificial mechanisms overload the articular surfaces and constrain biological joint kinematics. It is desired to better understand the deformable articular geometries of biological joints in vivo during movements for design and control of wearable robotics. An articular geometry reconstruction method is proposed to measure the effective articular profile with a wearable compliant device and illustrated with its application to knee-joint kinematic analysis. Regarding the joint articulation as boundary constraints for the compliant mechanism, the equivalent articular geometry is constructed from the beam deformations driven by knee motions, where the continuous deformations are estimated with strain data from the embedded sensors. Both simulated analysis and experimental validation are presented to justify the proposed method.
Collapse
|
10
|
Komnik I, David S, Funken J, Haberer C, Potthast W, Weiss S. Compromised knee internal rotation in total knee arthroplasty patients during stair climbing. PLoS One 2018; 13:e0205492. [PMID: 30304032 PMCID: PMC6179266 DOI: 10.1371/journal.pone.0205492] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2018] [Accepted: 09/26/2018] [Indexed: 11/19/2022] Open
Abstract
Due to the significant role of rotational properties for normal knee function, this study aimed to investigate transverse plane kinematics and kinetics in total knee arthroplasty and unicondylar knee arthroplasty patients during activities of daily living compared to a healthy control group, including stair ascent and descent. The study participants consisted of a total knee arthroplasty group including posterior cruciate retaining and posterior stabilized designs as well as a unicondylar knee arthroplasty group and a healthy control group. Three-dimensional kinematics and kinetics were captured using a Vicon system and two Kistler force plates embedded in the floor and another two in a staircase. Inverse dynamics of the lower limbs was computed in Anybody™ Modeling System. Transverse plane joint angles and joint moments were analyzed utilizing the statistical non-parametric mapping approach, considering the entire curve shape for statistical analysis. The patients with total knee arthroplasty exhibited significantly reduced knee internal rotation of the operated knee compared to the control group and the patients’ unimpaired limb, especially during the stair climbing tasks. Both unicondylar and total knee arthroplasty patients were found to have similar reduced internal rotation motion time series in stair descent. In conclusion, potential kinematic and kinetic benefits of unicondylar knee arthroplasty over total knee arthroplasty could not be proven in the current study. Aside from the usually mentioned reasons inducing constrained knee internal rotation in total knee arthroplasty patients, future studies should investigate to what extent co-contraction may contribute to this functional impairment in patients after knee arthroplasty surgery.
Collapse
Affiliation(s)
- Igor Komnik
- Institute of Biomechanics and Orthopaedics, German Sport University Cologne, Cologne, Nordrhein-Westfalen, Germany
- * E-mail:
| | - Sina David
- Institute of Biomechanics and Orthopaedics, German Sport University Cologne, Cologne, Nordrhein-Westfalen, Germany
| | - Johannes Funken
- Institute of Biomechanics and Orthopaedics, German Sport University Cologne, Cologne, Nordrhein-Westfalen, Germany
| | | | - Wolfgang Potthast
- Institute of Biomechanics and Orthopaedics, German Sport University Cologne, Cologne, Nordrhein-Westfalen, Germany
| | - Stefan Weiss
- ARCUS Clinics Pforzheim, Pforzheim, Baden-Württemberg, Germany
| |
Collapse
|
11
|
Gait comparison of unicompartmental knee arthroplasty and total knee arthroplasty during level walking. PLoS One 2018; 13:e0203310. [PMID: 30161216 PMCID: PMC6117028 DOI: 10.1371/journal.pone.0203310] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2018] [Accepted: 08/18/2018] [Indexed: 11/19/2022] Open
Abstract
This meta-analysis compared the gait patterns of unicompartmental knee arthroplasty (UKA) patients and total knee arthroplasty (TKA) patients during level walking by evaluating the kinetics, kinematics, and spatiotemporal parameters. Studies were included in the meta-analysis if they assessed the vertical ground reaction force (GRF), joint moment at stance, flexion at initial contact, flexion at swing, overall range of motion (ROM), coronal knee angle at stance, walking speed, cadence, and stride length in UKA patients or TKA patients. Seven non-randomized studies met the criteria for inclusion in this meta-analysis. UKA patients and TKA patients were similar in terms of vertical GRF (95% CI: -0.36 to 0.20; P = 0.60), joint moment (95% CI: -0.55 to 0.63; P = 0.90), kinematic outcomes (95% CI: -0.72 to 1.02; P = 0.74), walking speed (95% CI: -0.27 to 0.81; P = 0.32), and cadence (95% CI: -0.14 to 0.68; P = 0.20). In contrast, the stride length (95% CI: 0.01 to 0.80; P = 0.04) differed significantly between groups. Subgroup analyses revealed that the pooled data were similar between the groups: 1st maximum (heel strike), -0.18 BW (P = 0.53); 1st minimum (mid-stance), -0.43 BW (P = 0.08); and 2nd maximum (toe off), -0.03 BW (P = 0.87). On gait analysis, there were no significant differences in vertical GRF, joint moment at stance, overall kinematics, walking speed, or cadence between UKA patients and TKA patients during level walking. However, the TKA group had significantly shorter stride length than UKA patients. Although the comparison was inconclusive in determining which types of knee arthroplasty offered the closest approximation to normal gait, we consider it important to provide better rehabilitation programs to reduce the abnormal stride length in TKA patients compared to UKA patients.
Collapse
|
12
|
Redish MH, Fennema P. Good results with minimally invasive unicompartmental knee resurfacing after 10-year follow-up. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY 2017; 28:959-965. [PMID: 29167979 PMCID: PMC6003968 DOI: 10.1007/s00590-017-2079-5] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/09/2017] [Accepted: 11/12/2017] [Indexed: 10/25/2022]
Abstract
The current study was designed to determine (1) 10-year implant survival and (2) patient's self-reported functional outcome in a single surgeon's consecutive cohort of patients who had undergone minimally invasive unicondylar resurfacing with a modified cementation technique utilizing a cobalt-chromium femur/inlaid all-PE tibia, fixed-bearing unicompartmental prosthesis. We included 344 consecutive patients (361 knees) who had received the study device between January 2002 and December 2005 in this retrospective study. After 10 years, 78 patients (78 knees) had died, 59 (59 knees) were lost to follow-up and four (four knees) did not participate. Thirteen knees (11 patients) were revised after a mean of 5.8 ± 1.9 years. Hence, the study population at follow-up comprised 192 patients (207 knees). Ten-year implant survival was 94.6% (95% confidence interval, 90.9-96.8%). The Forgotten Joint Score and Oxford Knee Score were 68.9 ± 28.9 and 39 ± 9.1, respectively. Excellent survivorship and clinical outcomes were obtained with UKA with an inlaid all-PE tibia with a modified cementation technique.
Collapse
Affiliation(s)
- Martin H Redish
- Parkridge Bone and Joint, 2205 McCallie Ave. Suite 102, Chattanooga, TN, 37404, USA.
| | - Peter Fennema
- AMR Advanced Medical Research GmbH, Hofenstrasse 89b, 8708, Männedorf, Switzerland
| |
Collapse
|
13
|
Komnik I, Peters M, Funken J, David S, Weiss S, Potthast W. Non-Sagittal Knee Joint Kinematics and Kinetics during Gait on Level and Sloped Grounds with Unicompartmental and Total Knee Arthroplasty Patients. PLoS One 2016; 11:e0168566. [PMID: 28002437 PMCID: PMC5176302 DOI: 10.1371/journal.pone.0168566] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2016] [Accepted: 12/04/2016] [Indexed: 11/19/2022] Open
Abstract
After knee arthroplasty (KA) surgery, patients experience abnormal kinematics and kinetics during numerous activities of daily living. Biomechanical investigations have focused primarily on level walking, whereas walking on sloped surfaces, which is stated to affect knee kinematics and kinetics considerably, has been neglected to this day. This study aimed to analyze over-ground walking on level and sloped surfaces with a special focus on transverse and frontal plane knee kinematics and kinetics in patients with KA. A three-dimensional (3D) motion analysis was performed by means of optoelectronic stereophogrammetry 1.8 ± 0.4 years following total knee arthroplasty (TKA) and unicompartmental arthroplasty surgery (UKA). AnyBody™ Modeling System was used to conduct inverse dynamics. The TKA group negotiated the decline walking task with reduced peak knee internal rotation angles compared with a healthy control group (CG). First-peak knee adduction moments were diminished by 27% (TKA group) and 22% (UKA group) compared with the CG during decline walking. No significant differences were detected between the TKA and UKA groups, regardless of the locomotion task. Decline walking exposed apparently more abnormal knee frontal and transverse plane adjustments in KA patients than level walking compared with the CG. Hence, walking on sloped surfaces should be included in further motion analysis studies investigating KA patients in order to detect potential deficits that might be not obvious during level walking.
Collapse
Affiliation(s)
- Igor Komnik
- Institute for Biomechanics and Orthopaedics, German Sport University Cologne, Cologne, Nordrhein-Westfalen, Germany
| | - Markus Peters
- Institute for Biomechanics and Orthopaedics, German Sport University Cologne, Cologne, Nordrhein-Westfalen, Germany
| | - Johannes Funken
- Institute for Biomechanics and Orthopaedics, German Sport University Cologne, Cologne, Nordrhein-Westfalen, Germany
| | - Sina David
- Institute for Biomechanics and Orthopaedics, German Sport University Cologne, Cologne, Nordrhein-Westfalen, Germany
| | - Stefan Weiss
- ARCUS Clinics Pforzheim, Pforzheim, Baden-Württemberg, Germany
| | - Wolfgang Potthast
- Institute for Biomechanics and Orthopaedics, German Sport University Cologne, Cologne, Nordrhein-Westfalen, Germany
| |
Collapse
|
14
|
Measurement of rotational and coronal alignment in total knee arthroplasty using a navigation system is reproducible. Arch Orthop Trauma Surg 2016; 136:271-6. [PMID: 26739138 DOI: 10.1007/s00402-015-2402-8] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/17/2015] [Indexed: 02/09/2023]
Abstract
INTRODUCTION Intraoperative kinematic analysis using a navigation system in total knee arthroplasty (TKA) has been increasing. The purpose of the present study was to assess the reproducibility of the intraoperative kinematics analysis in TKA using the image-free knee navigation system. MATERIALS AND METHODS Fifty-one knees in 45 patients who received TKA, performed by a single surgeon (the senior consultant) with the resident, were included in this retrospective study. There were 7 men and 38 women and the mean age was 74.3 years. Cruciate retaining (CR) type and posterior stabilized (PS) type implants were inserted into 38 and 13 knees. The senior consultant and the resident analyzed initial kinematics, the axial rotation of the tibia and the coronal alignment of the lower limb, three times in each knee on manual passive knee flexion intraoperatively using the navigation system. Intra-class correlation coefficients (ICC) with 95 % confidence intervals were calculated to determine the reproducibility of this analysis. RESULTS In regard to intra-rater reproducibility with axial rotation of the tibia, the ICC of the senior consultant was 0.965 for CR knees and 0.972 for PS knees while the ICC of the resident were 0.966 and 0.956. Inter-rater reproducibility was excellent for both knee types (ICC, 0.885 for CR knees and 0.864 for PS knees). In regard to intra-rater reproducibility with coronal alignment of the lower limb, ICC of the senior consultant was 0.990 for CR knees and 0.996 for PS knees while those of the resident were 0.990 and 0.995. Inter-rater reproducibility was also excellent for both knee types (ICC, 0.978 for CR knees and 0.994 for PS knees). CONCLUSIONS Manual intraoperative kinematic analysis using a navigation system in TKA showed excellent reproducibility. This result may encourage further studies about intraoperative kinematic analysis using a navigation system in TKA.
Collapse
|