1
|
Dutta S, Ambade R, Wankhade D, Agrawal P. Rehabilitation Techniques Before and After Total Knee Arthroplasty for a Better Quality of Life. Cureus 2024; 16:e54877. [PMID: 38533163 PMCID: PMC10965116 DOI: 10.7759/cureus.54877] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2023] [Accepted: 02/25/2024] [Indexed: 03/28/2024] Open
Abstract
The most important gold standard treatment following advanced knee osteoarthritis is total knee arthroplasty. Following surgery of total knee replacement, the majority of patients report decreased pain and successful long-term results, but recovery is unpredictable, and most patients continue to exhibit muscle weakness in their lower limbs and functional limitations in comparison to similarly aged control individuals. The goal of this review article was to systematically review different articles containing controlled and randomized studies to find out the effectiveness of outpatient care postoperatively on short- and long-term functional recovery. The purpose of this review article is to investigate the possible advantages of pre- and postoperative rehabilitation as well as the value of exercise regimen recommendations following total knee replacement. The following interventions after total knee arthroplasty are discussed in this review article: preoperative education and exercises, continuous passive movement, strengthening interventions, aquatic therapy, balanced training, tourniquet exposure, use of alignment and implants, role of apps in phones and different wearable devices, influence of postoperative protocols, knee bracing, neuromuscular electrical stimulation, and clinical environment. Strengthening and intense functional exercises for patients above 45 years of age, in land or water programs like aquatic activities, with the increasing intensity of the exercises in accordance with the patient's progress, should be included in the best outpatient physical therapy protocols. Because these exercises are so precisely personalized, the best long-term effects after surgery may come from outpatient physiotherapy performed in a clinical setting under the supervision of a registered physiotherapist or medical professional. This review article also includes the change in the quality and well-being of a patient's life who has undergone total knee arthroplasty and practiced the rehabilitation techniques.
Collapse
Affiliation(s)
- Sushmita Dutta
- Orthopaedics, Jawaharlal Nehru Medical College, Datta Meghe Institute of Higher Education & Research, Wardha, IND
| | - Ratnakar Ambade
- Orthopaedics, Jawaharlal Nehru Medical College, Datta Meghe Institute of Higher Education & Research, Wardha, IND
| | - Dhanashree Wankhade
- Orthopaedics, Jawaharlal Nehru Medical College, Datta Meghe Institute of Higher Education & Research, Wardha, IND
| | - Palak Agrawal
- Orthopaedics, Jawaharlal Nehru Medical College, Datta Meghe Institute of Higher Education & Research, Wardha, IND
| |
Collapse
|
2
|
Srivastava AK. American Academy of Orthopaedic Surgeons Clinical Practice Guideline Summary of Surgical Management of Osteoarthritis of the Knee. J Am Acad Orthop Surg 2023; 31:1211-1220. [PMID: 37883429 DOI: 10.5435/jaaos-d-23-00338] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/24/2023] [Accepted: 08/29/2023] [Indexed: 10/28/2023] Open
Abstract
The Surgical Management of Osteoarthritis of the Knee Evidence-Based Clinical Practice Guideline is based on a systematic review of published studies for surgical management of osteoarthritis of the knee in skeletally mature patients. This guideline contains 16 recommendations and seven options to assist orthopaedic surgeons and all qualified physicians with the surgical management of patients with osteoarthritis of the knee based on the best current available evidence. It is also intended to serve as an information resource for professional healthcare practitioners and developers of practice guidelines and recommendations. In addition to providing pragmatic practice recommendations, this guideline also highlights gaps in the literature and informs areas for future research and quality measure development.
Collapse
|
3
|
Hinloopen JH, Puijk R, Nolte PA, Schoones JW, de Ridder R, Pijls BG. The efficacy and safety of patient-specific instrumentation in primary total knee replacement: a systematic review and meta-analysis. Expert Rev Med Devices 2023; 20:245-252. [PMID: 36736371 DOI: 10.1080/17434440.2023.2177152] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
INTRODUCTION Patient-specific instrumentation (PSI) for primary total knee arthroplasty (TKA) surgery has been shown to increase accuracy of component positioning. However, it is unclear whether this also translates to actual benefits for patients in terms of better outcomes (efficacy) or less complications such as revisions (safety). We therefore systematically reviewed the literature to determine the efficacy and safety of PSI in primary TKA. METHODS Randomized controlled trials comparing PSI to non-PSI in primary TKA were included. A random effects model was used with meta-regression in case of heterogeneity. RESULTS Forty-three studies were included with a total of 1816 TKA in the PSI group and 1887 TKA in the control group. There were no clinically relevant differences between the PSI-group and non-PSI group regarding all outcomes. There was considerable heterogeneity: meta-regression analyses showed that the year the study was published was an important effect modifier. Early publications tended to show a positive effect for PSI compared to non-PSI TKA, whereas later studies found the opposite. CONCLUSION Based on evidence of moderate certainty, our study suggested that there were no clinically relevant differences in efficacy and safety between patients treated with PSI TKA and patients treated with non-PSI TKA.
Collapse
Affiliation(s)
- J H Hinloopen
- Department of Orthopaedics, Leiden University Medical Center, Leiden, The Netherlands
| | - R Puijk
- Department of Orthopedic Surgery, Spaarne Gasthuis, Hoofddorp, the Netherlands
| | - P A Nolte
- Department of Orthopedic Surgery, Spaarne Gasthuis, Hoofddorp, the Netherlands.,Department Oral Cell Biology, Academic Centre for Dentistry (ACTA), University of Amsterdam and Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
| | - J W Schoones
- Directorate of Research Policy (Formerly: Walaeus Library), Leiden University Medical Centre, Leiden, The Netherlands
| | - R de Ridder
- Department of Orthopaedics, Leiden University Medical Center, Leiden, The Netherlands.,Department of Orthopaedics, Reinier Haga Orthopaedic Centre, Zoetermeer, Netherlands
| | - B G Pijls
- Department of Orthopaedics, Leiden University Medical Center, Leiden, The Netherlands
| |
Collapse
|
4
|
Correction of ankle varus deformity using patient-specific dome-shaped osteotomy guides designed on weight-bearing CT: a pilot study. Arch Orthop Trauma Surg 2023; 143:791-799. [PMID: 34562121 DOI: 10.1007/s00402-021-04164-9] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/13/2021] [Accepted: 09/01/2021] [Indexed: 12/24/2022]
Abstract
BACKGROUND Dome-shaped supramalleolar osteotomies are a well-established treatment option for correcting ankle deformity. However, the procedure remains technically demanding and is limited by a two-dimensional (2D) radiographic planning of a three-dimensional (3D) deformity. Therefore, we implemented a weight-bearing CT (WBCT) to plan a 3D deformity correction using patient-specific guides. METHODS A 3D-guided dome-shaped supramalleolar osteotomy was performed to correct ankle varus deformity in a case series of five patients with a mean age of 53.8 years (range 47-58). WBCT images were obtained to generate 3D models, which enabled a deformity correction using patient-specific guides. These technical steps are outlined and associated with a retrospective analysis of the clinical outcome using the EFAS score, Foot and Ankle Outcome Score (FAOS) and visual analog pain scale (VAS). Radiographic assessment was performed using the tibial anterior surface angle (TAS), tibiotalar angle (TTS), talar tilt angle (TTA), hindfoot angle (HA), tibial lateral surface angle (TLS) and tibial rotation angle (TRA). RESULTS The mean follow-up was 40.8 months (range 8-65) and all patients showed improvements in the EFAS score, FAOS and VAS (p < 0.05). A 3-month postoperative WBCT confirmed healing of the osteotomy site and radiographic improvement of the TAS, TTS and HA (p < 0.05), but the TTA and TRA did not change significantly (p > 0.05). CONCLUSION Dome-shaped supramalleolar osteotomies using 3D-printed guides designed on WBCT are a valuable option in correcting ankle varus deformity and have the potential to mitigate the technical drawbacks of free-hand osteotomies. LEVEL OF EVIDENCE Level 5 case series.
Collapse
|
5
|
Rudran B, Magill H, Ponugoti N, Williams A, Ball S. Functional outcomes in patient specific instrumentation vs. conventional instrumentation for total knee arthroplasty; a systematic review and meta-analysis of prospective studies. BMC Musculoskelet Disord 2022; 23:702. [PMID: 35870913 PMCID: PMC9308296 DOI: 10.1186/s12891-022-05620-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/01/2021] [Accepted: 07/05/2022] [Indexed: 11/18/2022] Open
Abstract
Background Total Knee Arthroplasty (TKA) is an established surgical option for knee osteoarthritis (OA). There are varying perceptions of the most suitable surgical technique for making bone cuts in TKA. Conventional Instrumentation (CI) uses generic cutting guides (extra- and intra-medullary) for TKA; however, patient specific instrumentation (PSI) has become a popular alternative amongst surgeons. Methods A literature search of electronic databases Embase, Medline and registry platform portals was conducted on the 16th May 2021. The search was performed using a predesigned search strategy. Eligible studies were critically appraised for methodological quality. The primary outcome measure was Knee Society Function Score. Functional scores were also collected for the secondary outcome measures: Oxford Knee Score (OKS), Western Ontario and McMaster Universities Arthritis Index (WOMAC), Knee Injury and Osteoarthritis Outcome Score (KOOS) and Visual Analog Scale (VAS) for pain. Review Manager 5.3 was used for all data synthesis and analysis. Results There is no conclusive evidence in the literature to suggest that PSI or CI instrumentation is better for functional outcomes. 23 studies were identified for inclusion in this study. Twenty-two studies (18 randomised controlled trials and 4 prospective studies) were included in the meta analysis, with a total of 2277 total knee arthroplasties. There were 1154 PSI TKA and 1123 CI TKA. The majority of outcomes at 3-months, 6-months and 12 show no statistical difference. There was statistical significance at 24 months in favour of PSI group for KSS function (mean difference 4.36, 95% confidence interval 1.83–6.89). The mean difference did not exceed the MCID of 6.4. KSS knee scores demonstrated statistical significance at 24 months (mean difference 2.37, 95% confidence interval (CI) 0.42—4.31), with a MCID of 5.9. WOMAC scores were found to be statistically significant favouring PSI group at 12 months (mean difference -3.47, 95% confidence interval (CI) -6.57- -0.36) and 24 months (mean difference -0.65, 95% confidence interval (CI) -1.28—-0.03), with high level of bias noted in the studies and a MCID of 10. Conclusions This meta-analysis of level 1 and level 2 evidence shows there is no clinical difference when comparing PSI and CI KSS function scores for TKA at definitive post operative time points (3 months, 6 months, 12 months and 24 months). Within the secondary outcomes for this study, there was no clinical difference between PSI and CI for TKA. Although there was no clinical difference between PSI and CI for TKA, there was statistical significance noted at 24 months in favour of PSI compared to CI for TKA when considering KSS function, KSS knee scores and WOMAC scores. Studies included in this meta-analysis were of limited cohort size and prospective studies were prone to methodological bias. The current literature is limited and insufficiently robust to make explicit conclusions and therefore further high-powered robust RCTs are required at specific time points.
Collapse
|
6
|
Via GG, Brueggeman DA, Lyons JG, Ely IC, Froehle AW, Krishnamurthy AB. Funding has no effect on clinical outcomes of total joint arthroplasty emerging technologies: a systematic review of bibliometrics and conflicts of interest. ARTHROPLASTY (LONDON, ENGLAND) 2022; 4:45. [PMID: 36316729 PMCID: PMC9623935 DOI: 10.1186/s42836-022-00146-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/27/2022] [Accepted: 08/14/2022] [Indexed: 11/06/2022]
Abstract
Background The use of new total joint arthroplasty technologies, including patient-specific implants/instrumentation (PSI), computer-assisted (CA), and robotic-assisted (RA) techniques, is increasing. There is an ongoing debate regarding the value provided and potential concerns about conflicts of interest (COI). Methods PRISMA guidelines were followed. PubMed, MEDLINE, and Web of Science databases were searched for total hip and knee arthroplasties, unicompartmental knee arthroplasties (UKA), PSI, CA, and RA. Bibliometric data, financial COI, clinical/functional scores, and patient-reported outcomes were assessed. Results Eighty-seven studies were evaluated, with 35 (40.2%) including at least one author reporting COI, and 13 (14.9%) disclosing industry funding. COI and industry funding had no significant effects on outcomes (P = 0.682, P = 0.447), and there were no significant effects of conflicts or funding on level of evidence (P = 0.508, P = 0.826). Studies in which author(s) disclosed COI had significantly higher relative citation ratio (RCR) and impact factor (IF) than those without (P < 0.001, P = 0.032). Subanalysis demonstrated RA and PSI studies were more likely to report COI or industry funding (P = 0.045). RA (OR = 6.31, 95% CI: 1.61–24.68) and UKA (OR = 9.14, 95% CI: 1.43–58.53) had higher odds of reporting favorable outcomes than PSI. Conclusions Author COIs (about 40%) may be lower than previously reported in orthopedic technologies/techniques reviews. Studies utilizing RA and PSI were more likely to report COI, while RA and UKA studies were more likely to report favorable outcomes than PSI. No statistically significant association between the presence of COIs and/or industry funding and the frequency of favorable outcomes or study level of evidence was found. Level of evidence Level V Systematic Review Supplementary Information The online version contains supplementary material available at 10.1186/s42836-022-00146-3.
Collapse
Affiliation(s)
- Garrhett G. Via
- grid.268333.f0000 0004 1936 7937Department of Orthopedic Surgery, Wright State University, 30 E. Apple St., Ste 2200, Dayton, OH 45409 USA
| | - David A. Brueggeman
- grid.268333.f0000 0004 1936 7937Department of Orthopedic Surgery, Wright State University, 30 E. Apple St., Ste 2200, Dayton, OH 45409 USA
| | - Joseph G. Lyons
- grid.268333.f0000 0004 1936 7937Department of Orthopedic Surgery, Wright State University, 30 E. Apple St., Ste 2200, Dayton, OH 45409 USA
| | - Isabelle C. Ely
- grid.268333.f0000 0004 1936 7937Department of Orthopedic Surgery, Wright State University, 30 E. Apple St., Ste 2200, Dayton, OH 45409 USA
| | - Andrew W. Froehle
- grid.268333.f0000 0004 1936 7937Department of Orthopedic Surgery, Wright State University, 30 E. Apple St., Ste 2200, Dayton, OH 45409 USA
| | - Anil B. Krishnamurthy
- grid.268333.f0000 0004 1936 7937Department of Orthopedic Surgery, Wright State University, 30 E. Apple St., Ste 2200, Dayton, OH 45409 USA
| |
Collapse
|
7
|
Luan Y, Zhang M, Ran T, Wang H, Fang C, Nie M, Wang M, Cheng CK. Correlation between component alignment and short-term clinical outcomes after total knee arthroplasty. Front Surg 2022; 9:991476. [PMID: 36311927 PMCID: PMC9606652 DOI: 10.3389/fsurg.2022.991476] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2022] [Accepted: 09/26/2022] [Indexed: 12/05/2022] Open
Abstract
OBJECTIVE This study aimed to investigate the correlation between component alignment and short-term clinical outcomes after total knee arthroplasty (TKA). METHODS 50 TKA patients from a regional hospital were enrolled in the study. The following component alignments were measured from radiological data acquired within 1 week after surgery: hip-knee-ankle angle (HKA), medial distal femoral angle (MDFA), medial proximal tibial angle (MPTA), femoral flexion-extension angle (FEA), tibial slope angle (TSA), femoral rotational angle (FRA) and tibial rotational angle (TRA). The Hospital for Special Surgery (HSS) knee scoring system was used to assess clinical outcomes after 1 year, with patients being divided into three groups (excellent, good and not good) according to the HSS scores. Difference analysis and linear correlation analysis were used for the statistical analysis. RESULTS The results showed significant differences in MDFA (p = 0.050) and FEA (p = 0.001) among the three patient groups. It was also found that the total HSS had only a moderate correlation with FEA (r = 0.572, p < 0.001), but FEA had a positive linear correlation with pain scores (r = 0.347, p = 0.013), function scores (r = 0.535, p = 0.000), ROM scores (r = 0.368, p = 0.009), muscle scores (r = 0.354, p = 0.012) and stability scores (r = 0.312, p = 0.028). A larger MDFA was associated with lower FE deformity scores (r = -0.289, p = 0.042) and the TSA had a positive influence on the ROM (r = 0.436, p = 0.002). Also, changes in FRA produced a consequent change in the FE deformity score (r = 0.312, p = 0.027), and the muscle strength scores increased as TRA increased (r = 0.402, p = 0.004). CONCLUSION The results show that the FEA plays a significant role in clinical outcomes after TKA. Surgical techniques and tools may need to be improved to accurately adjust the FEA to improve joint functionality and patient satisfaction.
Collapse
Affiliation(s)
- Yichao Luan
- School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Min Zhang
- School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Tianfei Ran
- Department of Orthopaedics, Xinqiao Hospital, Army Military Medical University, Chongqing, China
| | - Huizhi Wang
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Chaohua Fang
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China,Department of Joint Surgery, Ningbo No.6 Hospital, Ningbo, China
| | - Maodan Nie
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Min Wang
- Department of Orthopaedics, Xinqiao Hospital, Army Military Medical University, Chongqing, China,Correspondence: Min Wang Cheng-Kung Cheng
| | - Cheng-Kung Cheng
- School of Biological Science and Medical Engineering, Beihang University, Beijing, China,School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China,Correspondence: Min Wang Cheng-Kung Cheng
| |
Collapse
|
8
|
Clinical outcomes after using patient specific instrumentation: is it worth the effort? A minimum 5-year retrospective review of 298 PSI knees. Arch Orthop Trauma Surg 2022; 143:3409-3422. [PMID: 36214876 PMCID: PMC9549813 DOI: 10.1007/s00402-022-04593-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/15/2021] [Accepted: 08/10/2022] [Indexed: 11/02/2022]
Abstract
INTRODUCTION Use of patient specific instrumentation (PSI) for performing total knee arthroplasty (TKA) has been shown to improve component positioning but there is dearth of evidence regarding clinical outcomes. The aim of our study was to report patient satisfaction and functional outcome scores of patients who underwent PSI TKAs at minimum 5 year follow up. METHODS This is a retrospective study of a prospectively collected data of patients who underwent PSI TKAs between January 2012 and October 2015 under a single surgeon. Patient Reported Outcome Measures (PROMs), patient satisfaction questionnaires, surgeon directed 3D planning changes and intra-operative changes were collected and analysed. RESULTS The cohort included 298 consecutive PSI TKAs performed on 249 patients at a mean age of 71 years (range: 49-93 years). On an average 4 changes were made for each knee during 3D planning compared to preliminary plan. Intra-operative implant size change was required only in 3% (10 knees). The PROM scores were collected at a mean follow-up period of 6.8 years (range: 5.0-8.6 years) for 224 knees. Oxford Knee Score improved from median pre-operative score of 18 (IQR: 13-24) to median post-operative score of 44 (IQR: 40-47) with a median gain of 23 (IQR: 16-30). The median modified Forgotten Joint Score was 87.5 (IQR: 54.4-98.1). For the Beverland questionnaire, 75% (n = 166) reported being "Very Happy" and only 4% (n = 9/222) were 'Never Happy'. CONCLUSION Excellent patient satisfaction and functional scores at mid-term can be achieve d using PSI technique to perform TKA with careful surgeon directed pre-operative planning.
Collapse
|
9
|
Dong Z, Li Y, Tian H. [Research progress on comparison of the application effects between personal specific instrumentation and computer-assisted navigation surgery in total knee arthroplasty]. ZHONGGUO XIU FU CHONG JIAN WAI KE ZA ZHI = ZHONGGUO XIUFU CHONGJIAN WAIKE ZAZHI = CHINESE JOURNAL OF REPARATIVE AND RECONSTRUCTIVE SURGERY 2021; 35:1492-1498. [PMID: 34779179 DOI: 10.7507/1002-1892.202104048] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
Objective To compare the application effects between personal specific instrumentation (PSI) and computer-assisted navigation surgery (CAS) in total knee arthroplasty (TKA). Methods The literature comparing the application effects of PSI and CAS in TKA in recent years was widely consulted, and the difference between PSI-TKA and CAS-TKA in operation time, lower limb alignment, blood loss, and knee function were compared. Results Compared to CAS-TKA, PSI-TKA simplifies operation procedures and shortens operation time but probably has worse lower limb alignment. It is still controversial in comparison of perioperative blood loss and knee function between two techniques. Conclusion PSI-TKA and CAS-TKA both have advantages and disadvantages, and their differences need to be confirmed by further high-quality clinical trial.
Collapse
Affiliation(s)
- Ziyang Dong
- Department of Orthopedics, Peking University Third Hospital, Beijing, 100191, P.R.China.,Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing, 100191, P.R.China
| | - Yang Li
- Department of Orthopedics, Peking University Third Hospital, Beijing, 100191, P.R.China.,Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing, 100191, P.R.China
| | - Hua Tian
- Department of Orthopedics, Peking University Third Hospital, Beijing, 100191, P.R.China.,Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing, 100191, P.R.China
| |
Collapse
|
10
|
Time-Driven Activity-Based Costing Provides a Lower and More Accurate Assessment of Costs in the Field of Orthopaedic Surgery Compared With Traditional Accounting Methods. Arthroscopy 2021; 37:1620-1627. [PMID: 33232748 DOI: 10.1016/j.arthro.2020.11.028] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/23/2020] [Revised: 11/01/2020] [Accepted: 11/02/2020] [Indexed: 02/02/2023]
Abstract
PURPOSE To analyze the implementation and benefits of time-driven activity-based costing (TDABC) in the field of orthopaedic surgery. METHODS We performed a search of PubMed, Google Scholar, and Embase in March 2020, using the following terms: "Time-Driven Activity-Based Costing," "TDABC," "Orthopaedic Surgery," and "Cost." Then we selected the studies that used the TDABC methodology to generate costs for a particular aspect of orthopaedic surgery. The included studies were divided into the following 5 main categories for ease of analysis: joint arthroplasty, trauma, hand, electronic medical record (EMR) implementation, and pediatric. We analyzed the overall ability of TDABC in the field of orthopaedic surgery, compared to the standard costing methods. RESULTS We included a total of 19 studies that implemented the TDABC methodology to generate a cost, which was compared to traditional accounting methods. The orthopaedic subspecialty with the most amount of TDABC implementation has been the field of joint arthroplasty. In these studies, the authors have noted that TDABC has provided a more granular breakdown of costs and has calculated a lower cost compared with traditional accounting methods. CONCLUSION TDABC is a powerful cost analysis method that has demonstrated benefit over the activity-based costing (ABC) approach in determining a lower and more accurate cost of orthopaedic procedures. Furthermore, the TDABC method generates an average cost reduction of $10,000 and $12,000 for total hip arthroplasty and total knee arthroplasty, respectively. CLINICAL RELEVANCE TDABC can allow health care administration to better determine and understand the cost drivers of particular orthopaedic procedures at their institutions. With improved estimates on the true cost of an activity, hospital administrators and department chairs can adjust to ensure cost-effective, patient-centered health care.
Collapse
|
11
|
Patientenspezifische Instrumentierung und Totalendoprothesen am Knie. ARTHROSKOPIE 2021. [DOI: 10.1007/s00142-021-00460-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
Zusammenfassung
Hintergrund
Die patientenspezifische Instrumentierung (PSI) ist eine vielversprechende neue Technologie in der orthopädischen Chirurgie, die das Ziel verfolgt, die Implantationstechnik der Knietotalendoprothese (Knie-TEP) im Vergleich zur konventionellen Instrumentierung zu vereinfachen und präziser zu machen. Ziel dieses Artikels ist es, Vorteile und Grenzen der PSI für die primäre Knie-TEP zu beschreiben.
Material und Methoden
Es erfolgte eine umfassende Literaturrecherche zum Thema PSI in der Knieprothetik hinsichtlich Evidenz für Planung, Präzision, klinische Ergebnisse, intraoperative Parameter sowie Kosten und Effizienz.
Ergebnisse
Die dreidimensionale Computertomographie (CT) weist in der präoperativen Planung der Knie-TEP eine höhere Genauigkeit auf als 2‑D-Röntgenaufnahmen. Die meisten Arbeiten postulierten keine signifikanten Effekte zugunsten der Genauigkeit der PSI gegenüber der Standard-Knie-TEP. Aber sie berichteten auch nicht, dass die Genauigkeit mit PSI schlechter sei. Hinsichtlich des klinischen Outcomes gibt es genügend Konsens unter den veröffentlichten Studien, um festzuhalten, dass es kurz- und mittelfristig keinen Unterschied zwischen Patienten gibt, die mit PSI oder konventioneller Technik operiert wurden. Eine große Metaanalyse konnte weder eine kürzere Operationszeit noch eine geringere Komplikationsrate für die PSI-Knie-TEP feststellen. Lediglich der intraoperative Blutverlust erwies sich als niedriger im Vergleich zur Standardtechnik, jedoch mit unveränderter Transfusionsrate. Kosteneffektivitätsanalysen lassen schlussfolgern, dass die PSI aktuell (noch) nicht kosteneffektiv ist.
Diskussion
Obwohl die aktuell vorliegenden Studienergebnisse die PSI-Technologie hinsichtlich vieler messbaren Kriterien nicht eindeutig von der Standardtechnik abheben, zeigt die PSI viele theoretische und praktische Vorteile.
Collapse
|
12
|
León-Muñoz VJ, Parrinello A, Manca S, Galloni G, López-López M, Martínez-Martínez F, Santonja-Medina F. Patient-Specific Instrumentation Accuracy Evaluated with 3D Virtual Models. J Clin Med 2021; 10:jcm10071439. [PMID: 33916110 PMCID: PMC8036812 DOI: 10.3390/jcm10071439] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2021] [Revised: 03/20/2021] [Accepted: 03/24/2021] [Indexed: 12/25/2022] Open
Abstract
There have been remarkable advances in knee replacement surgery over the last few decades. One of the concerns continues to be the accuracy in achieving the desired alignment. Patient-specific instrumentation (PSI) was developed to increase component placement accuracy, but the available evidence is not conclusive. Our study aimed to determine a PSI system’s three-dimensional accuracy on 3D virtual models obtained by post-operative computed tomography. We compared the angular placement values of 35 total knee arthroplasties (TKAs) operated within a year obtained with the planned ones, and we analyzed the possible relationships between alignment and patient-reported outcomes. The mean (SD) discrepancies measured by two experienced engineers to the planned values observed were 1.64° (1.3°) for the hip–knee–ankle angle, 1.45° (1.06°) for the supplementary angle of the femoral lateral distal angle, 1.44° (0.97°) for the proximal medial tibial angle, 2.28° (1.78°) for tibial slope, 0.64° (1.09°) for femoral sagittal flexion, and 1.42° (1.06°) for femoral rotation. Neither variables related to post-operative alignment nor the proportion of change between pre-and post-operative alignment influenced the patient-reported outcomes. The evaluated PSI system’s three-dimensional alignment analysis showed a statistically significant difference between the angular values planned and those obtained. However, we did not find a relevant effect size, and this slight discrepancy did not impact the clinical outcome.
Collapse
Affiliation(s)
- Vicente J. León-Muñoz
- Department of Orthopaedic Surgery and Traumatology, Hospital Clínico Universitario Virgen de la Arrixaca, Ctra. Madrid-Cartagena, s/n, 30120 Murcia, Spain; (F.M.-M.); (F.S.-M.)
- Correspondence:
| | - Andrea Parrinello
- Product Management Department, Medacta International SA, Strada Regina, 6874 Castel San Pietro, Switzerland;
| | - Silvio Manca
- Patient Matched Technology Department, Medacta International SA, Strada Regina, 6874 Castel San Pietro, Switzerland; (S.M.); (G.G.)
| | - Gianluca Galloni
- Patient Matched Technology Department, Medacta International SA, Strada Regina, 6874 Castel San Pietro, Switzerland; (S.M.); (G.G.)
| | - Mirian López-López
- Subdirección General de Tecnologías de la Información, Servicio Murciano de Salud, Avenida Central, 7, Edificio Habitamia, Espinardo, 30100 Murcia, Spain;
| | - Francisco Martínez-Martínez
- Department of Orthopaedic Surgery and Traumatology, Hospital Clínico Universitario Virgen de la Arrixaca, Ctra. Madrid-Cartagena, s/n, 30120 Murcia, Spain; (F.M.-M.); (F.S.-M.)
- Department of Surgery, Pediatrics and Obstetrics & Gynecology, Faculty of Medicine, University of Murcia, 30100 Murcia, Spain
| | - Fernando Santonja-Medina
- Department of Orthopaedic Surgery and Traumatology, Hospital Clínico Universitario Virgen de la Arrixaca, Ctra. Madrid-Cartagena, s/n, 30120 Murcia, Spain; (F.M.-M.); (F.S.-M.)
- Department of Surgery, Pediatrics and Obstetrics & Gynecology, Faculty of Medicine, University of Murcia, 30100 Murcia, Spain
| |
Collapse
|
13
|
Pailhé R. Total knee arthroplasty: Latest robotics implantation techniques. Orthop Traumatol Surg Res 2021; 107:102780. [PMID: 33333275 DOI: 10.1016/j.otsr.2020.102780] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/04/2019] [Accepted: 04/24/2020] [Indexed: 02/03/2023]
Abstract
The recent introduction of new robotic systems for total knee arthroplasty (TKA) has created somewhat of a craze. Nevertheless, we can ask ourselves whether it is justified to use these new but very costly technologies. The results and limitations of these robotic tools must be analyzed systematically before confirming their benefits. Most of the newest robotic systems are interactive ones. These systems can accurately restore the mechanical axis and can improve the ligament balance and implant positioning. Theoretically, this can lead to better survival, function and outcomes. Recent studies have shown that use of robotics for TKA implantation does not increase the surgery time and does not cause more complications. Nevertheless, the long-term advantages of robotics use in this context remains to be proven. This task will be more difficult since there is currently no consensus as to the ideal positioning of TKA implants for a given patient. The aim of this study is to summarize this topic by answering the following questions: What are the different types of robots that can be used for TKA implantation? Which steps of the TKA surgical procedure are done with robotic arm assistance? What are the outcomes of these new implantation techniques? What are the limitations of these new implantation techniques? LEVEL OF EVIDENCE: V; expert opinion.
Collapse
Affiliation(s)
- Régis Pailhé
- Service de chirurgie de l'arthrose et du sport, urgences traumatiques des membres, hôpital Sud, CHU de Grenoble-Alpes, avenue de Kimberley, BP 338, 38434 Échirolles, France.
| |
Collapse
|
14
|
Lei K, Liu LM, Xiang Y, Chen X, Fan HQ, Peng Y, Luo JM, Guo L. Clinical value of CT-based patient-specific 3D preoperative design combined with conventional instruments in primary total knee arthroplasty: a propensity score-matched analysis. J Orthop Surg Res 2020; 15:591. [PMID: 33298106 PMCID: PMC7724895 DOI: 10.1186/s13018-020-02123-5] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/01/2020] [Accepted: 11/25/2020] [Indexed: 12/02/2022] Open
Abstract
Purpose To evaluate the operation and early clinical effect in primary total knee arthroplasty (TKA) about the novel combination of CT-based patient-specific three-dimensional (3D) preoperative design and conventional osteotomy instruments, compared with the conventional method. Methods After a 1:1 propensity score-matching (PSM), patients were matched to the novel technique group and the conventional group, 109 cases in each group. The conventional group adopted a preoperative design based on a full-length radiograph (FLX) and received TKA with conventional osteotomy instruments. The novel technique group used a CT-based patient-specific 3D preoperative design combined with conventional osteotomy instruments; during the surgery, the femoral entry point, femoral valgus osteotomy angle, the fix point of tibial plateau extramedullary guide pin, and the position of tibial extramedullary positioning rod were accurately selected according to the preoperative 3D design to ensure accurate intraoperative implementation. The lower limb alignment, component position, operation time, tourniquet time, hospital stay, blood loss volume, incidence of postoperative complications, visual analog scale (Vas) score, and New Knee Society Score System (NEW-KSS) at 1 day before operation and 1, 6, and 12 months after operation were recorded and compared. Results The novel technique group was significantly better than the conventional group in controlling lateral tibial component angle (LTC) (P < 0.001), and the novel technique group had lower percentages of hip-knee-ankle angle (HKA) outliers (P < 0.001) and overcorrection (P = 0.003). The operation time, tourniquet time, and hospital stay of the novel technique group was shorter (P < 0.05). In 1 month after the operation, the novel technique group achieved a significantly better VAS score (P < 0.05), but a similar NEW-KSS score (P > 0.05) when compared with the conventional group. But in 6 and 12 months after surgery, no statistical differences were seen in the above two scores (P > 0.05). Conclusion The novel technique of CT-based patient-specific 3D preoperative design combined with conventional instruments can improve the accuracy of osteotomy in primary total knee arthroplasty, with benefits of significantly reducing pain and rapid recovery during the early postoperative period, but having no obvious effect on outcome after a 1-year follow-up.
Collapse
Affiliation(s)
- Kai Lei
- Center for Joint Surgery, Southwest Hospital, Third Military Medical University, No. 30 Gaotanyan Street, Shapingba District, Chongqing, 400036, China
| | - Li Ming Liu
- Center for Joint Surgery, Southwest Hospital, Third Military Medical University, No. 30 Gaotanyan Street, Shapingba District, Chongqing, 400036, China
| | - Yi Xiang
- Department of Orthopaedics, Logistic Support Forces of the Chinese PLA 985 Hospital, No. 30 Qiaodong Street, Taiyuan, 030001, Shanxi, China
| | - Xin Chen
- Center for Joint Surgery, Southwest Hospital, Third Military Medical University, No. 30 Gaotanyan Street, Shapingba District, Chongqing, 400036, China
| | - Hua Quan Fan
- Center for Joint Surgery, Southwest Hospital, Third Military Medical University, No. 30 Gaotanyan Street, Shapingba District, Chongqing, 400036, China
| | - Yang Peng
- Center for Joint Surgery, Southwest Hospital, Third Military Medical University, No. 30 Gaotanyan Street, Shapingba District, Chongqing, 400036, China
| | - Jiang Ming Luo
- Center for Joint Surgery, Southwest Hospital, Third Military Medical University, No. 30 Gaotanyan Street, Shapingba District, Chongqing, 400036, China
| | - Lin Guo
- Center for Joint Surgery, Southwest Hospital, Third Military Medical University, No. 30 Gaotanyan Street, Shapingba District, Chongqing, 400036, China.
| |
Collapse
|
15
|
Li Z, Yang Z, Liao W, Wang W, Zou Y, Pan Y, Feng Z. Fewer femoral rotational outliers produced with CT- than with MRI-based patient-specific instrumentation in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 2020; 28:2930-2941. [PMID: 31435705 DOI: 10.1007/s00167-019-05678-x] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/08/2019] [Accepted: 08/02/2019] [Indexed: 01/27/2023]
Abstract
PURPOSE Previous studies comparing the surgical accuracy between computed tomography (CT)- and magnetic resonance imaging (MRI)-based patient-specific instrumentation (PSI) methods have produced contradictory results. The aim of this study was to determine which is the more reliable imaging method (CT versus MRI) for patient-specific total knee arthroplasty (TKA). CT-based PSI is hypothesised to have an advantage regarding the number of outliers. METHODS A total of 22 randomised controlled trials (RCTs), including 1749 TKA cases, were eligible for the meta-analysis. RCTs, systematic reviews and meta-analyses on this topic published in databases before September 2018 were identified by a literature search. The primary outcome was the number of lower extremities with greater than 3° of difference in alignment angles between the postoperative outcomes and target outcomes. The parameters calculated from the meta-analysis included risk ratios (RRs) and 95% confidence intervals (CIs). Additionally, the publication bias and heterogeneity of the studies were assessed. RESULTS The risk of femoral rotational outliers in the PSI group (RR = 0.48; 95% CI 0.24-0.98) was significantly reduced. Furthermore, subgroup analysis showed that the accuracy in the CT-based PSI group was significantly higher than that in the MRI-based CSI group (RR = 0.31; 95% CI 0.10-0.92). CONCLUSION This meta-analysis shows that when performing TKA with PSI, preoperative CT is beneficial for the production of the PSI, resulting in a significantly lower proportion of outliers in femoral rotational alignment. CT should be the preferred choice for imaging when performing TKA surgery with PSI to obtain better femoral rotational alignment. LEVEL OF EVIDENCE Therapeutic study (systematic review and meta-analysis), Level I.
Collapse
Affiliation(s)
- Zhihao Li
- Guangzhou University of Traditional Chinese Medicine, No. 12, Jichang Road, Baiyun District, Guangzhou, 510403, Guangdong, People's Republic of China
- The Foshan Hospital of Traditional Chinese Medicine, No. 6, Qinren Road, Chancheng District, Foshan, 528000, Guangdong, People's Republic of China
| | - Zhidong Yang
- The Foshan Hospital of Traditional Chinese Medicine, No. 6, Qinren Road, Chancheng District, Foshan, 528000, Guangdong, People's Republic of China
| | - Wencui Liao
- The Liuzhou Hospital of Traditional Chinese Medicine, No. 32, Jiefang North Road, Chengzhong District, Liuzhou, 545000, Guangxi, People's Republic of China
| | - Weigang Wang
- The Foshan Hospital of Traditional Chinese Medicine, No. 6, Qinren Road, Chancheng District, Foshan, 528000, Guangdong, People's Republic of China
| | - Yonggen Zou
- The Foshan Hospital of Traditional Chinese Medicine, No. 6, Qinren Road, Chancheng District, Foshan, 528000, Guangdong, People's Republic of China
| | - Yaocheng Pan
- The Foshan Hospital of Traditional Chinese Medicine, No. 6, Qinren Road, Chancheng District, Foshan, 528000, Guangdong, People's Republic of China
| | - Zongquan Feng
- Guangzhou University of Traditional Chinese Medicine, No. 12, Jichang Road, Baiyun District, Guangzhou, 510403, Guangdong, People's Republic of China.
- The Foshan Hospital of Traditional Chinese Medicine, No. 6, Qinren Road, Chancheng District, Foshan, 528000, Guangdong, People's Republic of China.
| |
Collapse
|
16
|
Siegel MA, Balach T, Sweeney KR, Nystrom LM, Colman MW. Sacroiliac joint cut accuracy: Comparing new technologies in an idealized sawbones model. J Surg Oncol 2020; 122:1218-1225. [PMID: 32761627 DOI: 10.1002/jso.26124] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2020] [Revised: 06/25/2020] [Accepted: 07/07/2020] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND OBJECTIVES The anatomical complexity of the pelvis creates challenges for orthopaedic oncologists to accurately and safely resect tumors involving the sacroiliac joint. Current technology may help overcome these obstacles. METHODS Four fellowship-trained orthopaedic oncologists performed 22 all-posterior sacroiliac cuts using freehand, computerized navigation, and patient-specific cutting guides on a Sawbones male pelvis model. Cut accuracies to preoperative planned margins were analyzed via a high-resolution optical scanner. Soft tissue damage was determined by visually inspecting the Sawbones foam placed on the far side of the cut. RESULTS Within 5 mm of the margins, the freehand technique resulted in 67.0% cut accuracy, the navigation technique had 71.1%, and the patient-specific cutting guide technique had 85.6% (P = .093). Within 2 mm, the techniques showed an accuracy of 25.8%, 32.5%, and 47.5%, respectively (P = .022). Regarding soft tissue damage, the freehand technique exhibited minimal penetration damage for 16.7% of the cuts, while navigation and patient-specific guide techniques exhibited 25.0% and 75.0%, respectively (P = .046). Years of surgical experience of the operator (1-7) did not influence the cut accuracy for any method. CONCLUSIONS Under ideal conditions, patient-specific guide technology possesses the same or better accuracy as other cutting techniques as well as the circumvention of soft tissue damage.
Collapse
Affiliation(s)
- Matthew A Siegel
- Department of Orthopaedic Surgery, College of Medicine, University of Illinois at Chicago, Chicago, Illinois
| | - Tessa Balach
- Department of Orthopaedic Surgery and Rehabilitation Medicine, University of Chicago, Chicago, Illinois
| | - Kyle R Sweeney
- Department of Orthopedic Surgery, University of Kansas Medical Center, Kansas, Kansas
| | | | - Matthew W Colman
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois
| |
Collapse
|
17
|
Patient-Specific or Conventional Instrumentations: A Meta-analysis of Randomized Controlled Trials. BIOMED RESEARCH INTERNATIONAL 2020; 2020:2164371. [PMID: 32258107 PMCID: PMC7085852 DOI: 10.1155/2020/2164371] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/11/2019] [Accepted: 02/13/2020] [Indexed: 02/05/2023]
Abstract
Objective To conduct a meta-analysis of randomized controlled trials (RCTs) to compare knee arthroplasty with patient-specific instrumentation (PSI) with the conventional instrumentation (CI). Methods RCTs were selected in PubMed and Embase from 2012 to 2018. Key data extracted included malalignment of mechanical axis, blood loss, surgical time, Oxford Knee Score (OKS), Knee Society Score (KSS), length of stay, and complications. Subgroup analysis was also performed regarding different PSI systems and different image processing methods. Results 29 RCTs with 2487 knees were eligible for the meta-analysis. Results showed that PSI did not improve the alignment of the mechanical axis compared with CI, but MRI-based PSI and Visionaire-specific PSI decrease the risk of malalignment significantly (P = 0.04 and P = 0.04 and P = 0.04 and P = 0.04 and P = 0.04 and Conclusion PSI reduced the blood loss and improved KSS. MRI-based PSI reduced operative time and risk of malalignment of mechanical axis compared with CT-based PSI. Moreover, Visionaire-specific PSI achieves better alignment result of the mechanical axis than other systems.
Collapse
|
18
|
Kizaki K, Shanmugaraj A, Yamashita F, Simunovic N, Duong A, Khanna V, Ayeni OR. Total knee arthroplasty using patient-specific instrumentation for osteoarthritis of the knee: a meta-analysis. BMC Musculoskelet Disord 2019; 20:561. [PMID: 31759392 PMCID: PMC6875166 DOI: 10.1186/s12891-019-2940-2] [Citation(s) in RCA: 42] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/11/2019] [Accepted: 11/11/2019] [Indexed: 12/20/2022] Open
Abstract
BACKGROUND Total knee arthroplasty using patient-specific instrumentation (TKA-PSI), which are disposable cutting block guides generated to fit each patient's 3-dimensional knee anatomy, has been developed to treat patients with end-stage osteoarthritis of the knee. Surrogate markers such as radiographic malalignment have been well investigated, however, patient-important outcomes are not well examined to elucidate the efficacy of TKA-PSI. The aim of this review is to determine if TKA-PSI improves patient-reported outcome measures (PROM), surgery time, blood loss, transfusion and complications (e.g. surgical site infection, deep venous thrombosis, and revision TKA). METHODS We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, EMBASE, and ongoing clinical trials. For PROMs, surgery time, blood loss, and transfusion rate, we included randomized controlled trials (RCT) comparing TKA-PSI and standard TKA to treat osteoarthritis of the knee. For complications, we also included non-randomized comparative studies (non-RCT). RESULTS This review includes 38 studies, 24 of which were RCT and 14 of which were non-RCT. These included a total of 3487 patients. The predominant population in the included studies highly reflected the general population, with 62% being female, aged over 60 and having end-stage osteoarthritis of the knee. TKA-PSI did not improve PROMs as compared to standard TKA for less than 1-year (mean difference 0.48, 95% confidence interval (CI) -1.92-0.97 in the Oxford knee score, mean 3-month follow-up) and for 1-year or more (mean difference 0.25, 95%CI - 4.39-4.89 in the WOMAC score, mean 29-month follow-up). TKA-PSI did not reduce surgery time (mean difference - 3.09 min, 95%CI -6.73-0.55). TKA-PSI decreased blood loss with a small effect size corresponding to a 0.4 g/dl hemoglobin decrease (95%CI 0.18-0.88), but did not decrease transfusion rate (risk difference - 0.04, 95%CI -0.09-0.01). TKA-PSI did not reduce complication rates (risk difference 0.00, 95%CI - 0.01-0.01 in the composite outcome). CONCLUSIONS TKA-PSI does not improve patient-reported outcome measures, surgery time, and complication rates as compared to standard TKA. TKA-PSI decreases blood loss with a small effect, which is not enough to reduce transfusion rate.
Collapse
Affiliation(s)
- Kazuha Kizaki
- Department of Health Research Methods, Evidence, and Impact, McMaster University Medical Centre, McMaster University, 1200 Main St W, Hamilton, Ontario, L8N 3Z5, Canada.,Division of Orthopaedic Surgery, McMaster University, 1200 Main St W, Hamilton, Ontario, L8N 3Z5, Canada
| | - Ajaykumar Shanmugaraj
- Division of Orthopaedic Surgery, McMaster University, 1200 Main St W, Hamilton, Ontario, L8N 3Z5, Canada
| | - Fumiharu Yamashita
- Department of Orthopaedic surgery and rheumatology, Kyoto Shimogamo Hospital, 17 Shimogamo, Kyoto, 606-0866, Japan
| | - Nicole Simunovic
- Department of Health Research Methods, Evidence, and Impact, McMaster University Medical Centre, McMaster University, 1200 Main St W, Hamilton, Ontario, L8N 3Z5, Canada.,Division of Orthopaedic Surgery, McMaster University, 1200 Main St W, Hamilton, Ontario, L8N 3Z5, Canada
| | - Andrew Duong
- Division of Orthopaedic Surgery, McMaster University, 1200 Main St W, Hamilton, Ontario, L8N 3Z5, Canada
| | - Vickas Khanna
- Division of Orthopaedic Surgery, McMaster University, 1200 Main St W, Hamilton, Ontario, L8N 3Z5, Canada
| | - Olufemi R Ayeni
- Department of Health Research Methods, Evidence, and Impact, McMaster University Medical Centre, McMaster University, 1200 Main St W, Hamilton, Ontario, L8N 3Z5, Canada. .,Division of Orthopaedic Surgery, McMaster University, 1200 Main St W, Hamilton, Ontario, L8N 3Z5, Canada.
| |
Collapse
|
19
|
León-Muñoz V, Lisón-Almagro A, López-López M. Influence of instrumentation on the surgical time to implant a total knee prosthesis. Rev Esp Cir Ortop Traumatol (Engl Ed) 2019. [DOI: 10.1016/j.recote.2019.04.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022] Open
|
20
|
Laende EK, Richardson CG, Dunbar MJ. A randomized controlled trial of tibial component migration with kinematic alignment using patient-specific instrumentation versus mechanical alignment using computer-assisted surgery in total knee arthroplasty. Bone Joint J 2019; 101-B:929-940. [PMID: 31362561 DOI: 10.1302/0301-620x.101b8.bjj-2018-0755.r3] [Citation(s) in RCA: 62] [Impact Index Per Article: 12.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
AIMS Patient-specific instrumentation of total knee arthroplasty (TKA) is a technique permitting the targeting of individual kinematic alignment, but deviation from a neutral mechanical axis may have implications on implant fixation and therefore survivorship. The primary objective of this randomized controlled study was to compare the fixation of tibial components implanted with patient-specific instrumentation targeting kinematic alignment (KA+PSI) versus components placed using computer-assisted surgery targeting neutral mechanical alignment (MA+CAS). Tibial component migration measured by radiostereometric analysis was the primary outcome measure (compared longitudinally between groups and to published acceptable thresholds). Secondary outcome measures were inducible displacement after one year and patient-reported outcome measures (PROMS) over two years. The secondary objective was to assess the relationship between alignment and both tibial component migration and inducible displacement. PATIENTS AND METHODS A total of 47 patients due to undergo TKA were randomized to KA+PSI (n = 24) or MA+CAS (n = 23). In the KA+PSI group, there were 16 female and eight male patients with a mean age of 64 years (sd 8). In the MA+CAS group, there were 17 female and six male patients with a mean age of 63 years (sd 7). Surgery was performed using cemented, cruciate-retaining Triathlon total knees with patellar resurfacing, and patients were followed up for two years. The effect of alignment on tibial component migration and inducible displacement was analyzed irrespective of study group. RESULTS There was no difference over two years in longitudinal migration of the tibial component between the KA+PSI and MA+CAS groups (reaching median maximum total point motion migration at two years of 0.40 mm for the KA+PSI group and 0.37 mm for the MA+CAS group, p = 0.82; p = 0.68 adjusted for age, sex, and body mass index (BMI) for all follow-ups). Both groups had mean migrations below acceptable thresholds. There was no difference in inducible displacement (p = 0.34) or PROMS (p = 0.61 for the Oxford Knee Score) between groups. There was no correlation between alignment and tibial component migration or alignment and inducible displacement. These findings support non-neutral alignment as a viable option with this component, with no evidence that it compromises fixation. CONCLUSION Kinematic alignment using patient-specific instrumentation in TKA was associated with acceptable tibial component migration, indicating stable fixation. These results are supportive of future investigations of kinematic alignment. Cite this article: Bone Joint J 2019;101-B:929-940.
Collapse
Affiliation(s)
- E K Laende
- Department of Surgery, Dalhousie University, Halifax, Canada.,QEII Health Sciences Centre, Nova Scotia Health Authority, Halifax, Canada
| | - C G Richardson
- Department of Surgery, Dalhousie University, Halifax, Canada.,QEII Health Sciences Centre, Nova Scotia Health Authority, Halifax, Canada
| | - M J Dunbar
- Department of Surgery, Dalhousie University, Halifax, Canada.,QEII Health Sciences Centre, Nova Scotia Health Authority, Halifax, Canada
| |
Collapse
|
21
|
Abstract
Hip arthrodesis is a treatment option for painful chronic hip conditions. Hip fractures through a previously arthrodesed hip are relatively uncommon as indications for hip arthrodesis are rare. The following case reports on the use of a sliding hip screw and a pelvic reconstruction plate to address arthrodesed hip fracture in an 81-year-old man. The use of a dynamic hip screw in this setting gave us a stable fixed-angle construct with compression across the fracture site, and the addition of a trochanteric side plate added to the stability. The dynamic compression plate with limited bone contact was used to neutralize the construct. This case describes the successful treatment of such an injury in a way not previously described in the literature with the intent of giving the orthopaedic traumatologist another method to approach this rare injury.
Collapse
|
22
|
Randelli PS, Menon A, Pasqualotto S, Zanini B, Compagnoni R, Cucchi D. Patient-Specific Instrumentation Does Not Affect Rotational Alignment of the Femoral Component and Perioperative Blood Loss in Total Knee Arthroplasty: A Prospective, Randomized, Controlled Trial. J Arthroplasty 2019; 34:1374-1381.e1. [PMID: 30979672 DOI: 10.1016/j.arth.2019.03.018] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/20/2018] [Revised: 02/17/2019] [Accepted: 03/06/2019] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Proposed aims of patient-specific instrumentation (PSI) for total knee arthroplasty (TKA) are to improve accuracy of component alignment, while reducing blood loss and surgical time. The primary goal of this prospective, randomized, controlled, clinical trial is to verify whether PSI improves the rotational alignment of the femoral component in comparison to conventionally implanted TKA. METHODS One-hundred thirty-three consecutive patients were assessed for eligibility. Block randomization was performed to allocated patients in the treatment (PSI) or control group. During hospital stay, surgical times were recorded, and total blood volume loss and estimated red blood cell were calculated. Two months after surgery, a computed tomography of the knee was obtained to measure femoral component rotation to the transepicondylar axis and tibial component slope. RESULTS Sixty-nine patients were enrolled. PSI did neither result in a significant improvement in femoral component rotation nor result in a reduction of outliers, as compared with conventional instrumentation. No significant improvement in terms of tibial slope, blood loss, total surgical time, and ischemia time could be identified. The number of tibial recuts required in the PSI group was significantly higher than in the control group (P = .0003). CONCLUSION PSI does not improve the accuracy of femoral component rotation in TKA in comparison to conventional instrumentation. Moreover, PSI did not appear to influence any of the other variables investigated as secondary goals by this study. The results of this study do not support its routine use during standard TKA. LEVEL OF EVIDENCE Level I, randomized, controlled trial.
Collapse
Affiliation(s)
- Pietro S Randelli
- Department of Biomedical Sciences for Health, Laboratory of Applied Biomechanics, Università degli Studi di Milano, Milan, Italy; 1° Clinica Ortopedica, ASST Centro Specialistico Ortopedico Traumatologico Gaetano Pini-CTO, Milan, Italy
| | - Alessandra Menon
- Department of Biomedical Sciences for Health, Laboratory of Applied Biomechanics, Università degli Studi di Milano, Milan, Italy; 1° Clinica Ortopedica, ASST Centro Specialistico Ortopedico Traumatologico Gaetano Pini-CTO, Milan, Italy
| | - Stefano Pasqualotto
- Divisione di Ortopedia e Traumatologia, IRCCS Ospedale Classificato Equiparato Sacro Cuore - Don Calabria, Negrar, Italy
| | - Beatrice Zanini
- Dipartimento di Scienze della Salute, Università del Piemonte Orientale A. Avogadro, Novara, Italy
| | - Riccardo Compagnoni
- 1° Clinica Ortopedica, ASST Centro Specialistico Ortopedico Traumatologico Gaetano Pini-CTO, Milan, Italy
| | - Davide Cucchi
- Department of Biomedical Sciences for Health, Laboratory of Applied Biomechanics, Università degli Studi di Milano, Milan, Italy; Department of Orthopaedics and Trauma Surgery, Universitätsklinikum Bonn, Bonn, Germany
| |
Collapse
|
23
|
León-Muñoz VJ, Lisón-Almagro AJ, López-López M. Influence of instrumentation on the surgical time to implant a total knee prosthesis. Rev Esp Cir Ortop Traumatol (Engl Ed) 2019; 63:321-326. [PMID: 31182387 DOI: 10.1016/j.recot.2019.04.006] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2019] [Revised: 03/26/2019] [Accepted: 04/07/2019] [Indexed: 11/19/2022] Open
Abstract
OBJECTIVE To demonstrate if there is a difference in the time that the surgery is prolonged to implant a knee prosthesis according to the instrumentation system used. MATERIAL AND METHODS Retrospective analysis of the duration of 243 interventions (skin-to-skin time and ischemia time) performed by the same surgeon. Seventy-two cases operated with conventional instruments (IC), 68 by means of computer assisted surgery (CAS) and 103 with personalized instrumentation system (PSI). RESULTS IC skin-to-skin time 87,85 min (SD 11,86). IC ischemia time 94,44 min (SD 11,49). Computer assisted surgery skin-to-skin time 123,46 min (SD 11,27). Computer assisted surgery ischemia time 129,63 min (SD 11,37). PSI skin-to-skin time 78,69 min (SD 13,06). PSI ischemia time 84,63 min (SD 12,06). There is a significant difference between PSI and the other instrumentation systems (p 0,000). CONCLUSIONS In our study, the time consumption for the implantation of a knee prosthesis has been significantly lower when cutting blocks have been used, than when we have used other systems.
Collapse
Affiliation(s)
- V J León-Muñoz
- Servicio de Cirugía Ortopédica y Traumatología, Hospital Clínico Universitario Virgen de la Arrixaca, Murcia, España.
| | - A J Lisón-Almagro
- Servicio de Cirugía Ortopédica y Traumatología, Hospital de la Vega Lorenzo Guirao, Cieza, Murcia, España
| | - M López-López
- Subdirección General de Tecnologías de la Información, Servicio Murciano de Salud, Murcia, España
| |
Collapse
|
24
|
León-Muñoz VJ, Martínez-Martínez F, López-López M, Santonja-Medina F. Patient-specific instrumentation in total knee arthroplasty. Expert Rev Med Devices 2019; 16:555-567. [PMID: 31154870 DOI: 10.1080/17434440.2019.1627197] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
INTRODUCTION Total knee arthroplasty (TKA) is one of the most commonly performed orthopedic procedures. During the past decade, patient-specific instrumentation (PSI) has been commercially introduced in order to simplify and make TKA surgery more effective, precise and efficient than conventional mechanical instrumentation (CI) and computer-assisted surgery (CAS). Nevertheless, there are critical arguments against PSI for routine use. The aim of the current manuscript is to describe advantages and limitations of PSI for primary TKA. AREAS COVERED By means of a description of the available literature different aspects are discussed (accuracy, clinical and functional outcomes, operative time, blood loss, efficiency and costs). EXPERT OPINION Most publications do not claim a significant increase in PSI accuracy over CI, but they also do not postulate PSIs accuracy is worse either. Regarding clinical aspects, PSI did not appear to give any advantage over standard techniques although, equally, it did not appear to show any disadvantages. PSI seems to reduce operative time, could reduce perioperative blood loss and provides logistical benefits in the operation room. Further studies will be required to more thoroughly assess all the advantages and disadvantages of this promising technology as an alternative to CI and CAS.
Collapse
Affiliation(s)
- Vicente J León-Muñoz
- a Orthopaedic Surgery and Traumatology Department , Hospital Clínico Universitario Virgen de la Arrixaca , Murcia , Spain
| | - Francisco Martínez-Martínez
- a Orthopaedic Surgery and Traumatology Department , Hospital Clínico Universitario Virgen de la Arrixaca , Murcia , Spain.,b Faculty of Medicine , University of Murcia , Murcia , Spain
| | - Mirian López-López
- c Subdirección General de Tecnologías de la Información. Servicio Murciano de Salud , Murcia , Spain
| | - Fernando Santonja-Medina
- a Orthopaedic Surgery and Traumatology Department , Hospital Clínico Universitario Virgen de la Arrixaca , Murcia , Spain.,b Faculty of Medicine , University of Murcia , Murcia , Spain
| |
Collapse
|
25
|
Teeter MG, Marsh JD, Howard JL, Yuan X, Vasarhelyi EM, McCalden RW, Naudie DDR. A randomized controlled trial investigating the value of patient-specific instrumentation for total knee arthroplasty in the Canadian healthcare system. Bone Joint J 2019; 101-B:565-572. [DOI: 10.1302/0301-620x.101b5.bjj-2018-1323.r1] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Aims The purpose of the present study was to compare patient-specific instrumentation (PSI) and conventional surgical instrumentation (CSI) for total knee arthroplasty (TKA) in terms of early implant migration, alignment, surgical resources, patient outcomes, and costs. Patients and Methods The study was a prospective, randomized controlled trial of 50 patients undergoing TKA. There were 25 patients in each of the PSI and CSI groups. There were 12 male patients in the PSI group and seven male patients in the CSI group. The patients had a mean age of 69.0 years (sd 8.4) in the PSI group and 69.4 years (sd 8.4) in the CSI group. All patients received the same TKA implant. Intraoperative surgical resources and any surgical waste generated were recorded. Patients underwent radiostereometric analysis (RSA) studies to measure femoral and tibial component migration over two years. Outcome measures were recorded pre- and postoperatively. Overall costs were calculated for each group. Results There were no differences (p > 0.05) in any measurement of migration at two years for either the tibial or femoral components. Movement between one and two years was < 0.2 mm, indicating stable fixation. There were no differences in coronal or sagittal alignment between the two groups. The PSI group took a mean 6.1 minutes longer (p = 0.04) and used a mean 3.4 less trays (p < 0.0001). Total waste generated was similar (10 kg) between the two groups. The PSI group cost a mean CAD$1787 more per case (p < 0.01). Conclusion RSA criteria suggest that both groups will have revision rates of approximately 3% at five years. The advantages of PSI were minimal or absent for surgical resources used and waste eliminated, and for meeting target alignment, yet had significantly greater costs. Therefore, we conclude that PSI may not offer any advantage over CSI for routine primary TKA cases. Cite this article: Bone Joint J 2019;101-B:565–572.
Collapse
Affiliation(s)
- M. G. Teeter
- Department of Surgery, Schulich School of Medicine & Dentistry, Western University and London Health Science Centre, London, Canada
- Department of Medical Biophysics, Schulich School of Medicine &Dentistry, Western University, London, Canada
- Surgical Innovation Program, Lawson Health Research Institute, London, Canada
- Imaging Research Laboratories, Robarts Research Institute, London, Canada
- Bone and Joint Institute, Western University, London, Canada
| | - J. D. Marsh
- Bone and Joint Institute, Western University, London, Canada
- School of Physical Therapy, Faculty of Health Sciences, Western University, London, Canada
| | - J. L. Howard
- Department of Surgery, Schulich School of Medicine & Dentistry, Western University and London Health Science Centre, London, Canada
| | - X. Yuan
- Imaging Research Laboratories, Robarts Research Institute, London, Canada
| | - E. M. Vasarhelyi
- Department of Surgery, Schulich School of Medicine & Dentistry, Western University and London Health Science Centre, London, Canada
| | - R. W. McCalden
- Department of Surgery, Schulich School of Medicine & Dentistry, Western University and London Health Science Centre, London, Canada
| | - D. D. R. Naudie
- Department of Surgery, Schulich School of Medicine & Dentistry, Western University and London Health Science Centre, London, Canada
| |
Collapse
|
26
|
McAuliffe MJ, Beer BR, Hatch JJ, Crawford RW, Cuthbert AR, Donnelly WJ. Impact of Image-Derived Instrumentation on Total Knee Arthroplasty Revision Rates: An Analysis of 83,823 Procedures from the Australian Orthopaedic Association National Joint Replacement Registry. J Bone Joint Surg Am 2019; 101:580-588. [PMID: 30946191 DOI: 10.2106/jbjs.18.00326] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Computer navigation and image-derived instrumentation (IDI) are technology-based methods developed to improve outcomes and potentially reduce revision total knee arthroplasty (TKA). IDI refers to the use of manufactured, patient-specific surgical jigs. Conflicting reports exist on IDI-associated improvements in outcomes. The primary aim of the current study was to compare the rates of revision among TKA cases in which components were initially implanted with use of IDI, computer navigation, or neither of these methods ("other" TKA). The secondary aim was to determine whether the outcomes of IDI differed for specific subgroups. METHODS Data were obtained from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) for the 3 TKA groups: IDI, computer-navigated, and other TKA. The study period was from the first IDI procedure recorded by the AOANJRR (April 2010) to December 31, 2016. The analysis was restricted to primary TKA cases undertaken for osteoarthritis and involving patellar resurfacing and the use of a cross-linked polyethylene insert. Subanalyses were performed to evaluate the effects of age, sex, implantation method, IDI manufacturer, prosthetic design, and prosthesis type on the rates of revision. Kaplan-Meier estimates of survivorship described the time to first revision. Hazard ratios (HRs, Cox proportional hazards models) with adjustment for age and sex were used to compare revision rates. RESULTS IDI was used in 5,486 primary TKA procedures. There was no significant difference among the groups in the cumulative percent revision (CPR) at 5 years: 3.3% (95% confidence interval [CI], 2.4% to 4.6%) for IDI, 2.4% (95% CI, 2.2% to 2.7%) for the computer-navigated group, and 2.5% (95% CI, 2.3% to 2.7%) for other TKA. Posterior-stabilized TKA with use of the IDI method had a significantly higher rate of revision at >3 months (HR, 1.45 [95% CI, 1.02 to 2.04]; p = 0.036), as did IDI TKA in the ≤65-year-old patient cohort (HR, 1.52 [95% CI, 1.10 to 2.09]; p = 0.010), compared with computer-navigated TKA. Patellar revision was significantly more likely in the IDI group. CONCLUSIONS IDI TKA demonstrated no overall difference in early to mid-term revision rates compared with standard implantation methods. However, elevated rates of revision were seen with posterior-stabilized TKA, in patients ≤65 years of age, and for patellar revision, meaning that this method should be used with some caution and requires further study. LEVEL OF EVIDENCE Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Michael J McAuliffe
- Department of Orthopaedics, Ipswich Hospital, Ipswich, Queensland, Australia
| | - Benjamin R Beer
- Department of Orthopaedics, Ipswich Hospital, Ipswich, Queensland, Australia
| | - Joshua J Hatch
- Department of Orthopaedics, Ipswich Hospital, Ipswich, Queensland, Australia
| | - Ross W Crawford
- Queensland University of Technology, Brisbane City, Queensland, Australia
| | - Alana R Cuthbert
- South Australian Health and Medical Research Institute (SAHMRI), Adelaide, South Australia, Australia
| | - William J Donnelly
- Department of Orthopaedics, Prince Charles Hospital, Chermside, Queensland, Australia
| |
Collapse
|
27
|
Gong S, Xu W, Wang R, Wang Z, Wang B, Han L, Chen G. Patient-specific instrumentation improved axial alignment of the femoral component, operative time and perioperative blood loss after total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 2019; 27:1083-1095. [PMID: 30377714 PMCID: PMC6435625 DOI: 10.1007/s00167-018-5256-0] [Citation(s) in RCA: 39] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/04/2018] [Accepted: 10/19/2018] [Indexed: 12/29/2022]
Abstract
PURPOSE The purpose of the present study was to compare patient-specific instrumentation (PSI) with standard instrumentation (SI) in patients undergoing total knee arthroplasty (TKA). PSI is hypothesized to have advantages with respect to component alignment; number of outliers (defined as alignment > 3° from the target alignment); operative time; perioperative blood loss; and length of hospital stay. This new surgical technique is expected to exhibit superior performance. METHODS A total of 23 randomized controlled trials (RCTs) involving 2058 knees that compared the clinical outcomes of TKA between PSI and SI were included in the present analysis; these RCTs were identified via a literature search of the PubMed, Embase, and Cochrane Library databases through March 1, 2018. The outcomes of interest included coronal, sagittal and axial component alignment (presented as the angle of deviation from the transcondylar line); number of outliers; operative time; perioperative blood loss; and length of hospital stay. RESULTS There was a significant difference in postoperative femoral axial alignment between PSI and SI patients (95% CI - 0.71 to - 0.21, p = 0.0004, I2 = 48%). PSI resulted in approximately 0.4° less deviation from the transcondylar line than SI. Based on our results, PSI reduced operative time by a mean of 7 min compared with SI (95% CI - 10.95 to - 3.75, p < 0.0001, I2 = 78%). According to the included literature, PSI reduced perioperative blood loss by approximately 90 ml compared with SI (95% CI - 146.65 to - 20.18, p = 0.01, I2 = 74%). We did not find any differences between PSI and SI with respect to any other parameters. CONCLUSIONS PSI has advantages in axial alignment of the femoral component, operative time, and perioperative blood loss relative to SI. No significant differences were found between PSI and SI with respect to alignment of the remaining components, number of outliers, or length of hospital stay. LEVEL OF EVIDENCE Therapeutic study (systematic review and meta-analysis), Level I.
Collapse
Affiliation(s)
- Song Gong
- 0000 0004 0368 7223grid.33199.31Department of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022 China
| | - Weihua Xu
- Department of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, China.
| | - Ruoyu Wang
- 0000 0004 0368 7223grid.33199.31Department of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022 China
| | - Zijian Wang
- 0000 0004 0368 7223grid.33199.31Department of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022 China
| | - Bo Wang
- 0000 0004 0368 7223grid.33199.31Department of Rehabilitation, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022 China
| | - Lizhi Han
- 0000 0004 0368 7223grid.33199.31Department of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022 China
| | - Guo Chen
- 0000 0004 0368 7223grid.33199.31Department of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022 China
| |
Collapse
|
28
|
No improvement in reducing outliers in coronal axis alignment with patient-specific instrumentation. Knee Surg Sports Traumatol Arthrosc 2018; 26:2788-2796. [PMID: 29071356 DOI: 10.1007/s00167-017-4741-1] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/02/2017] [Accepted: 10/02/2017] [Indexed: 01/28/2023]
Abstract
PURPOSE AND HYPOTHESIS Patient-specific instrumentation (PSI) uses 3D preoperative imaging to produce individualized cutting blocks specific to patients' anatomy and according to the preoperative plan with the aim to reduce the number of mechanical leg alignment (MLA) outliers, to improve implant positioning and to decrease surgery time. The primary purpose of this study was to investigate the efficacy of a specific PSI in comparison with standard instrumentation (SI) in reducing the number of MLA outliers. It was hypothesized that the number of MLA outliers would be significantly lower in the PSI group. METHODS A multicenter randomized controlled trial was implemented. There were 59 patients in the PSI group and 66 in the SI group. The absolute number of outliers outside the ± 3° target neutral MLA was compared between the groups with a Chi-square test. As secondary outcomes, the Knee Society Score (KSS) and the Knee Injury and Osteoarthritis Outcome Score (KOOS) were compared between the groups preoperatively and at 90-day follow-up. RESULTS There were 15 (26.3%) MLA outliers in the PSI group and 8 (12.3%) in the SI group. The number of outliers was not independent from the group ( X2 (1) = 3.8, p = 0.04; Relative risk = 1.5). Preoperatively, there were no significant differences between the groups when comparing their KSS and KOOS sub-scores. At 90 days postoperatively, the patients in the SI group showed better KOOS-Quality of Life (KOSS-QOL) in comparison with the PSI group (p < 0.0001). CONCLUSION The use of PSI did not significantly reduce the number of MLA outliers in comparison with SI. There were no differences when comparing the achieved mean MLA of both groups. LEVEL OF EVIDENCE Level I, prospective randomized controlled trial.
Collapse
|
29
|
Schotanus MGM, Thijs E, Heijmans M, Vos R, Kort NP. Favourable alignment outcomes with MRI-based patient-specific instruments in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 2018; 26:2659-2668. [PMID: 28698929 DOI: 10.1007/s00167-017-4637-0] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/13/2017] [Accepted: 07/06/2017] [Indexed: 01/25/2023]
Abstract
PURPOSE Patient-specific instruments (PSIs) are already in relatively common use, and their post-operative radiographic results are equal to those for total knee arthroplasty (TKA) with conventional instrumentation. PSI use requires a preoperative MRI scan, CT scan, or a combination of MRI and a long-leg standing radiograph. However, there is no consensus as to which of these modalities, MRI or CT, is the preferred imaging modality when performing TKA with PSIs. METHODS This systematic literature review and meta-analysis studied the differences in alignment outliers between CT- and MRI-based PSI for TKA. A search of the Cochrane Database of Systematic Reviews, MEDLINE/PubMed and Embase was conducted, without restriction on date of publication. Only level I evidence studies written in English that included TKA with the use of MRI- and CT-based PSI were selected. A meta-analysis was then performed of the rate of outliers in the biomechanical axis and individual femoral and tibial component alignment. Where considerable heterogeneity among studies was present or the data did not provide sufficient information for performing the meta-analysis, a qualitative synthesis was undertaken. RESULTS Twelve randomized controlled trials, studying 841 knees, were eligible for data extraction and meta-analysis. MRI-based PSI resulted in a significantly lower proportion of coronal plane outliers with regard to the lateral femoral component (OR 0.52, 95% CI 0.30-0.89, P = 0.02), without significant heterogeneity (n.s.). There were no significant differences regarding the biomechanical axis or frontal femoral and individual tibial component alignment. CONCLUSION This systematic review and meta-analysis demonstrate that alignment with MRI-based PSI is at least as good as, if not better than, that with CT-based PSI. To prevent for malalignment, MRI should be the imaging modality of choice when performing TKA surgery with PSI. LEVEL OF EVIDENCE I.
Collapse
Affiliation(s)
- Martijn G M Schotanus
- Zuyderland Medical Centre, Dr H vd Hoffplein 1, 6162 AG, Sittard-Geleen, The Netherlands.
| | - Elke Thijs
- Zuyderland Medical Centre, Dr H vd Hoffplein 1, 6162 AG, Sittard-Geleen, The Netherlands
| | - Marion Heijmans
- Zuyderland Academy, Zuyderland Medical Centre, Sittard-Geleen, The Netherlands
| | - Rein Vos
- Department of Methodology and Statistics, Maastricht University Medical Center, Maastricht, The Netherlands
| | - Nanne P Kort
- Zuyderland Medical Centre, Dr H vd Hoffplein 1, 6162 AG, Sittard-Geleen, The Netherlands
| |
Collapse
|
30
|
Functional Outcomes and Accuracy of Patient-Specific Instruments for Total Knee Arthroplasty. Surg Innov 2018; 25:470-475. [DOI: 10.1177/1553350618787074] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Background. Patient-specific instruments (PSIs) were developed to improve mechanical axis alignment for patients undergoing total knee arthroplasty (TKA) as neutral alignment (180°) is a predictor of long-term success. This study examines alignment accuracy and functional outcomes of PSI as compared with standard instruments (SIs). Methods. We retrospectively reviewed a consecutive series of TKA procedures using PSI. A total of 85 PSI procedures were identified, and these were compared with a matched cohort of 85 TKAs using SI. Intraoperative decision-making, estimated blood loss, efficiency, Knee Society Scores, and postoperative radiographs were evaluated. Results. One hundred and seventy patients with comparable patient demographics were reviewed. Eighty-one percent of the PSI procedures were within target (180 ± 3°) mechanical alignment, while the SI group had 70% of cases within the target plane ( P = .132). Mean target alignment (2.0° PSI vs 2.2° SI, P = .477) was similar between groups. Twenty-seven percent of patients in the PSI group had surgeon-directed intraoperative recuts to improve the perceived coronal alignment. The change in hematocrit was reduced in the PSI group (8.89 vs 7.21, P = .000). Procedure time and total operating room time were equivalent. Knee Society Scores did not differ between groups at 6 months or at 1 year. Conclusion. Patient-specific instrumentation decreased change in hematocrit, though coronal alignment and efficiency were equivalent between groups. Surgeons must evaluate cuts intraoperatively to confirm alignment. Functional outcomes are equivalent for PSI and SI groups.
Collapse
|
31
|
Abane L, Zaoui A, Anract P, Lefevre N, Herman S, Hamadouche M. Can a Single-Use and Patient-Specific Instrumentation Be Reliably Used in Primary Total Knee Arthroplasty? A Multicenter Controlled Study. J Arthroplasty 2018; 33:2111-2118. [PMID: 29576488 DOI: 10.1016/j.arth.2018.02.038] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/28/2017] [Revised: 01/25/2018] [Accepted: 02/07/2018] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The aim of this controlled multicenter study is to evaluate the clinical and radiologic outcomes of primary total knee arthroplasty (TKA) using single-use fully disposable and patient-specific cutting guides (SU) and compare the results to those obtained with traditional patient-specific cutting guides (PSI) vs conventional instrumentation (CI). METHODS Seventy consecutive patients had their TKA performed using SU. They were compared to 140 historical patients requiring TKA that were randomized to have the procedure performed using PSI vs CI. The primary measure outcome was mechanical axis as measured on a standing long-leg radiograph using the hip-knee-ankle angle. Secondary outcome measures were Knee Society and Oxford knee scores, operative time, need for postoperative transfusion, and length of hospital stay. RESULTS The mean hip-knee-ankle value was 179.8° (standard deviation [SD] 3.1°), 179.2° (SD 2.9°), and 178.3° (SD 2.5°) in the CI, PSI and SU groups, respectively (P = .0082). Outliers were identified in 16 of 65 (24.6%), 15 of 67 (22.4%), and 14 of 70 (20.0%) knees in the CI, PSI, and SU group, respectively (P = .81). There was no significant difference in the clinical results (P = .29 and .19, respectively). Operative time, number of unit transfusion, and length of hospital stay were not significantly different between the 3 groups (P = .45, .31, and 0.98, respectively). CONCLUSION The use of an SU in TKA provided similar clinical and radiologic results to those obtained with traditional PSI and CI. The potential economic advantages of single-use instrumentation in primary TKA require further investigation.
Collapse
Affiliation(s)
- Laurent Abane
- Department of Orthopaedic and Reconstructive Surgery, Clinical Orthopaedics Research Center, Centre Hospitalo-Universitaire Cochin-Port Royal, Paris, France
| | - Amine Zaoui
- Department of Orthopaedic and Reconstructive Surgery, Clinical Orthopaedics Research Center, Centre Hospitalo-Universitaire Cochin-Port Royal, Paris, France
| | - Philippe Anract
- Department of Orthopaedic and Reconstructive Surgery, Clinical Orthopaedics Research Center, Centre Hospitalo-Universitaire Cochin-Port Royal, Paris, France
| | | | | | - Moussa Hamadouche
- Department of Orthopaedic and Reconstructive Surgery, Clinical Orthopaedics Research Center, Centre Hospitalo-Universitaire Cochin-Port Royal, Paris, France
| |
Collapse
|
32
|
Vaishya R, Vijay V, Vaish A, Agarwal AK. Computed tomography based 3D printed patient specific blocks for total knee replacement. J Clin Orthop Trauma 2018; 9:254-259. [PMID: 30202158 PMCID: PMC6128807 DOI: 10.1016/j.jcot.2018.07.013] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/17/2018] [Accepted: 07/17/2018] [Indexed: 12/11/2022] Open
Abstract
OBJECTIVES 3D printing is an emerging technology and its use in orthopaedics is being explored. We discuss the role of computed tomography based 3D printed patient specific jigs in total knee replacement. We also discuss the various advantages of 3D printed patient specific jigs and the future scope of their use in total knee replacement. METHODS A search of English literature was done and articles discussing the role of CT scan based 3D printed patient specific jigs in total knee replacement were included in the study. RESULTS The role of 3D printed jigs in total knee replacement have been found in the prediction of femoral valgus angle, component sizing and in retained hardware. They have shown promise with studies suggesting they might improve the overall mechanical alignment of the knee. There are studies which have also studied the combined role of patient specific instruments with navigation. CONCLUSION 3D printed jigs hold promise in total knee replacement. Their use in total knee replacement in the presence of retained hardware is useful for the surgeon. They have also showed promise in improving prediction of component sizing and improving mechanical alignment of the knee. Further studies with longer follow up and larger sample size will help in establishing their role in total knee replacement.
Collapse
Affiliation(s)
| | - Vipul Vijay
- Indraprastha Apollo Hospital, New Delhi, India
| | - Abhishek Vaish
- Central Institute of Orthopaedics, Safdarjung Hospital, New Delhi, India
| | | |
Collapse
|
33
|
Stetzelberger V, Obertacke U, Jawhar A. Tourniquet application during TKA did not affect the accuracy of implant positioning: a randomized clinical trial. Knee Surg Sports Traumatol Arthrosc 2018; 26:1728-1736. [PMID: 29058023 DOI: 10.1007/s00167-017-4760-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/08/2017] [Accepted: 10/12/2017] [Indexed: 11/24/2022]
Abstract
PURPOSE The accuracy of the identification of anatomical landmarks with versus without tourniquet application and its effect on implant positioning remained unknown. Therefore, the hypothesis of the present study was that tourniquet application did not affect the accuracy of the reconstruction of the mechanical leg alignment, the joint line level, and the patellar height. METHODS The prospective randomized monocentric trial (Clinical-Trials.gov NCT02475603) included a total of 86 patients scheduled to undergo primary TKA. The patients were allocated to receive TKA with (Group A, n = 43) or without tourniquet (Group B, n = 43). The mechanical leg alignment, the joint line level (modified Kawamura), and the patellar height (Plateau-patella angle, Insall Salvati index, and modified Insall Salvati index) were measured pre- and postoperatively on standardized calibrated digital radiographs. Mean, SEM, median, range, and p value were calculated for each parameter. RESULTS There was no statistical difference between the groups with regard to demographics, preoperative deformity, implant design, and surgical technique (n.s.). The mechanical leg alignment, the joint line level, and the patellar height revealed, in both groups, similar results pre- and postoperatively (n.s.). CONCLUSION The mechanical leg alignment, the joint line level, and the patellar height could be accurately reconstructed with and without tourniquet use. With respect to clinically relevant surrogate parameters of implant positioning, TKA can safely be performed without a tourniquet. Available data do not support a routine use of tourniquet during TKA and might justify a change of the clinical pathway. LEVEL OF EVIDENCE Level I.
Collapse
Affiliation(s)
- Vera Stetzelberger
- Department of Orthopaedics and Trauma Surgery, University Medical Center Mannheim of University Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany
| | - Udo Obertacke
- Department of Orthopaedics and Trauma Surgery, University Medical Center Mannheim of University Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany
| | - Ahmed Jawhar
- Department of Orthopaedics and Trauma Surgery, University Medical Center Mannheim of University Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany.
| |
Collapse
|
34
|
Luo X, Mori K, Peters TM. Advanced Endoscopic Navigation: Surgical Big Data, Methodology, and Applications. Annu Rev Biomed Eng 2018; 20:221-251. [PMID: 29505729 DOI: 10.1146/annurev-bioeng-062117-120917] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Interventional endoscopy (e.g., bronchoscopy, colonoscopy, laparoscopy, cystoscopy) is a widely performed procedure that involves either diagnosis of suspicious lesions or guidance for minimally invasive surgery in a variety of organs within the body cavity. Endoscopy may also be used to guide the introduction of certain items (e.g., stents) into the body. Endoscopic navigation systems seek to integrate big data with multimodal information (e.g., computed tomography, magnetic resonance images, endoscopic video sequences, ultrasound images, external trackers) relative to the patient's anatomy, control the movement of medical endoscopes and surgical tools, and guide the surgeon's actions during endoscopic interventions. Nevertheless, it remains challenging to realize the next generation of context-aware navigated endoscopy. This review presents a broad survey of various aspects of endoscopic navigation, particularly with respect to the development of endoscopic navigation techniques. First, we investigate big data with multimodal information involved in endoscopic navigation. Next, we focus on numerous methodologies used for endoscopic navigation. We then review different endoscopic procedures in clinical applications. Finally, we discuss novel techniques and promising directions for the development of endoscopic navigation.
Collapse
Affiliation(s)
- Xiongbiao Luo
- Department of Computer Science, Fujian Key Laboratory of Computing and Sensing for Smart City, Xiamen University, Xiamen 361005, China;
| | - Kensaku Mori
- Department of Intelligent Systems, Graduate School of Informatics, Nagoya University, Nagoya 464-8601, Japan;
| | - Terry M Peters
- Robarts Research Institute, Western University, London, Ontario N6A 3K7, Canada;
| |
Collapse
|
35
|
[Review of patient-specific instrumentation for total knee prosthesis]. ANNALES PHARMACEUTIQUES FRANÇAISES 2018; 76:228-234. [PMID: 29397920 DOI: 10.1016/j.pharma.2017.12.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2017] [Revised: 12/01/2017] [Accepted: 12/01/2017] [Indexed: 11/23/2022]
Abstract
OBJECTIVES Single use patient-specific instruments (PSI) for total knee prosthesis are introduced as a new alternative to conventional ancillaries and computer assisted surgery by improving implants positioning. An exhaustive review was carried out to identify their specific characteristics, with their advantages and disadvantages. METHODS Medical devices suppliers were consulted in 2015 for reviewing their PSI. Their technical, clinical and economic data were compared. The results had been submitted to an orthopaedics expert commission of our university hospital for clinical and financial opinion. RESULTS Ten companies have provided the documentation for the analysis. PSI are manufactured by suppliers using a three dimensional printing method based on CT scans or MRI images. PSI are produced according to the surgeon's preferences after a preliminary data check, which can be performed by the suppliers' engineers, the surgeon and automatic calculation. Five suppliers can produce sterile PSI with optional delivery of 3D bone models. According to the experts, the studies failed to demonstrate the superiority of a PSI or hospital economic gain. The prices listed remain high and operating room time is not always significantly reduced. CONCLUSIONS With the development of personalized medicine, the role of PSI grows in importance. They facilitate the surgeon's work by fully respecting the anatomy. These systems offer an interesting perspective in their technical and pedagogical aspects. But it seems premature to take them into routine use given the low number of high-level studies that were currently done.
Collapse
|
36
|
Canovas F, Dagneaux L. Quality of life after total knee arthroplasty. Orthop Traumatol Surg Res 2018; 104:S41-S46. [PMID: 29183821 DOI: 10.1016/j.otsr.2017.04.017] [Citation(s) in RCA: 179] [Impact Index Per Article: 29.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/06/2017] [Accepted: 04/14/2017] [Indexed: 02/02/2023]
Abstract
Total knee arthroplasty (TKA) results in a high degree of patient satisfaction, as it provides patients with considerable medium- and long-term benefits in terms of quality of life, pain relief and function. Nevertheless, the literature reports that up to 30% of patients are dissatisfied. This dissatisfaction is directly related to the patients' quality of life, which they deem insufficient. Their quality of life depends on many physical, behavioural, social and psychological factors that are not taken into account by functional outcome scores. After describing the principles of quality of life evaluation after TKA, we will assess the effects of patient-related factors, the surgical technique and postoperative program through an exhaustive review of the literature. Patient expectations after TKA will then be outlined, particularly return to work and return to sports.
Collapse
Affiliation(s)
- F Canovas
- Department of Orthopedic and Trauma Surgery, Upper limb and Spine Surgery Unit, Hôpital Lapeyronie, CHRU de Montpellier, 351, avenue du Doyen-Gaston-Giraud, 34295 Montpellier, France.
| | - L Dagneaux
- Department of Orthopedic and Trauma Surgery, Upper limb and Spine Surgery Unit, Hôpital Lapeyronie, CHRU de Montpellier, 351, avenue du Doyen-Gaston-Giraud, 34295 Montpellier, France
| |
Collapse
|
37
|
Alvand A, Khan T, Jenkins C, Rees JL, Jackson WF, Dodd CAF, Murray DW, Price AJ. The impact of patient-specific instrumentation on unicompartmental knee arthroplasty: a prospective randomised controlled study. Knee Surg Sports Traumatol Arthrosc 2018; 26:1662-1670. [PMID: 28831554 PMCID: PMC5966491 DOI: 10.1007/s00167-017-4677-5] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/16/2017] [Accepted: 08/14/2017] [Indexed: 11/29/2022]
Abstract
PURPOSE Patient-specific instrumentation (PSI) has been proposed as a means of improving surgical accuracy and ease of implantation during technically challenging procedures such as unicompartmental knee arthroplasty (UKA). The purpose of this prospective randomised controlled trial was to compare the accuracy of implantation and functional outcome of mobile-bearing medial UKAs implanted with and without PSI by experienced UKA surgeons. METHODS Mobile-bearing medial UKAs were implanted in 43 patients using either PSI guides or conventional instrumentation. Intra-operative measurements, meniscal bearing size implanted, and post-operative radiographic analyses were performed to assess component positioning. Functional outcome was determined using the Oxford Knee Score (OKS). RESULTS PSI guides could not be used in three cases due to concerns regarding accuracy and registration onto native anatomy, particularly on the tibial side. In general, similar component alignment and positioning was achieved using the two systems (n.s. for coronal/sagittal alignment and tibial coverage). The PSI group had greater tibial slope (p = 0.029). The control group had a higher number of optimum size meniscal bearing inserted (95 vs 52%; p = 0.001). There were no differences in OKS improvements (n.s). CONCLUSION Component positioning for the two groups was similar for the femur but less accurate on the tibial side using PSI, often with some unnecessarily deep resections of the tibial plateau. Although PSI was comparable to conventional instrumentation based on OKS improvements at 12 months, we continue to use conventional instrumentation for UKA at our institution until further improvements to the PSI guides can be demonstrated. LEVEL OF EVIDENCE Therapeutic, Level I.
Collapse
Affiliation(s)
- Abtin Alvand
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Botnar Research Centre, University of Oxford, Old Road, Oxford, OX3 7LD, UK.
| | - Tanvir Khan
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Botnar Research Centre, University of Oxford, Old Road, Oxford, OX3 7LD UK
| | - Cathy Jenkins
- Nuffield Orthopaedic Centre, Windmill Road, Headington, Oxford, OX3 7LD UK
| | - Jonathan L. Rees
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Botnar Research Centre, University of Oxford, Old Road, Oxford, OX3 7LD UK
| | - William F. Jackson
- Nuffield Orthopaedic Centre, Windmill Road, Headington, Oxford, OX3 7LD UK
| | | | - David W. Murray
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Botnar Research Centre, University of Oxford, Old Road, Oxford, OX3 7LD UK
| | - Andrew J. Price
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Botnar Research Centre, University of Oxford, Old Road, Oxford, OX3 7LD UK
| |
Collapse
|
38
|
Kawaguchi K, Michishita K, Manabe T, Akasaka Y, Higuchi J. Comparison of an Accelerometer-Based Portable Navigation System, Patient-Specific Instrumentation, and Conventional Instrumentation for Femoral Alignment in Total Knee Arthroplasty. Knee Surg Relat Res 2017; 29:269-275. [PMID: 29172387 PMCID: PMC5718798 DOI: 10.5792/ksrr.17.032] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/08/2017] [Revised: 07/18/2017] [Accepted: 07/24/2017] [Indexed: 10/26/2022] Open
Abstract
Purpose The KneeAlign2 (KA2, OrthoAlign Inc.) accelerometer-based portable navigation system and patient-specific instrumentation (PSI; Signature, ZimmerBiomet) are widely used for ideal femoral component alignment in total knee arthroplasty (TKA). However, there has been no comparative study of the KA2 system, PSI, and conventional intramedullary instrumentation (CON). The purpose of this study was to compare the accuracy in achieving proper femoral component alignment and clinical features by using the KA2 navigation system, PSI, and CON. Materials and Methods We retrospectively compared the accuracy of femoral component alignment of 34 TKAs performed with the KA2 system for implantation of the femoral component, 32 TKAs with PSI, and 33 TKAs with CON. Results In the coronal plane, use of the KA2 system was more likely to result in optimal femoral component alignment than the CON and PSI (p<0.01). In the sagittal plane, use of the KA2 system was more likely to result in optimal component alignment than PSI, but the difference between the KA2 and CON was insignificant. Conclusions The portable accelerometer-based KA2 navigation system enabled ideal femoral implantation in the coronal and sagittal planes, as compared to the PSI or CON.
Collapse
Affiliation(s)
- Kohei Kawaguchi
- Department of Orthopaedic, Japan Community Healthcare Organization, Yugawara Hospital, Kanagawa, Japan
| | - Kazuhiko Michishita
- Department of Orthopaedic, Japan Community Healthcare Organization, Yugawara Hospital, Kanagawa, Japan
| | - Takeshi Manabe
- Department of Orthopaedic, Japan Community Healthcare Organization, Yugawara Hospital, Kanagawa, Japan
| | - Yoshiyuki Akasaka
- Department of Orthopaedic, Japan Community Healthcare Organization, Yugawara Hospital, Kanagawa, Japan
| | - Junya Higuchi
- Department of Orthopaedic, Japan Community Healthcare Organization, Yugawara Hospital, Kanagawa, Japan
| |
Collapse
|
39
|
Biau DJ, Boulezaz S, Casabianca L, Hamadouche M, Anract P, Chevret S. Using Bayesian statistics to estimate the likelihood a new trial will demonstrate the efficacy of a new treatment. BMC Med Res Methodol 2017; 17:128. [PMID: 28830464 PMCID: PMC5568256 DOI: 10.1186/s12874-017-0401-x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2017] [Accepted: 08/02/2017] [Indexed: 12/29/2022] Open
Abstract
Background The common frequentist approach is limited in providing investigators with appropriate measures for conducting a new trial. To answer such important questions and one has to look at Bayesian statistics. Methods As a worked example, we conducted a Bayesian cumulative meta-analysis to summarize the benefit of patient-specific instrumentation on the alignment of total knee replacement from previously published evidence. Data were sourced from Medline, Embase, and Cochrane databases. All randomised controlled comparisons of the effect of patient-specific instrumentation on the coronal alignment of total knee replacement were included. The main outcome was the risk difference measured by the proportion of failures in the control group minus the proportion of failures in the experimental group. Through Bayesian statistics, we estimated cumulatively over publication time of the trial results: the posterior probabilities that the risk difference was more than 5 and 10%; the posterior probabilities that given the results of all previous published trials an additional fictive trial would achieve a risk difference of at least 5%; and the predictive probabilities that observed failure rate differ from 5% across arms. Results Thirteen trials were identified including 1092 patients, 554 in the experimental group and 538 in the control group. The cumulative mean risk difference was 0.5% (95% CrI: −5.7%; +4.5%). The posterior probabilities that the risk difference be superior to 5 and 10% was less than 5% after trial #4 and trial #2 respectively. The predictive probability that the difference in failure rates was at least 5% dropped from 45% after the first trial down to 11% after the 13th. Last, only unrealistic trial design parameters could change the overall evidence accumulated to date. Conclusions Bayesian probabilities are readily understandable when discussing the relevance of performing a new trial. It provides investigators the current probability that an experimental treatment be superior to a reference treatment. In case a trial is designed, it also provides the predictive probability that this new trial will reach the targeted risk difference in failure rates. Trial registration CRD42015024176. Electronic supplementary material The online version of this article (doi:10.1186/s12874-017-0401-x) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- David J Biau
- INSERM U1153, Paris, France. .,Service de chirurgie orthopédique,Hôpital Cochin, 27 rue du faubourg Saint-Jacques, 75014, Paris, France. .,Université Paris-Descartes, Paris 5, Paris, France.
| | - Samuel Boulezaz
- Service de chirurgie orthopédique,Hôpital Cochin, 27 rue du faubourg Saint-Jacques, 75014, Paris, France
| | - Laurent Casabianca
- Service de chirurgie orthopédique,Hôpital Cochin, 27 rue du faubourg Saint-Jacques, 75014, Paris, France
| | - Moussa Hamadouche
- Service de chirurgie orthopédique,Hôpital Cochin, 27 rue du faubourg Saint-Jacques, 75014, Paris, France
| | - Philippe Anract
- INSERM U1153, Paris, France.,Service de chirurgie orthopédique,Hôpital Cochin, 27 rue du faubourg Saint-Jacques, 75014, Paris, France
| | - Sylvie Chevret
- INSERM U1153, Paris, France.,Université Paris-Diderot, Paris 7, Paris, France
| |
Collapse
|
40
|
Zhu M, Chen JY, Chong HC, Yew AKS, Foo LSS, Chia SL, Lo NN, Yeo SJ. Outcomes following total knee arthroplasty with CT-based patient-specific instrumentation. Knee Surg Sports Traumatol Arthrosc 2017; 25:2567-2572. [PMID: 26410097 DOI: 10.1007/s00167-015-3803-5] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/24/2015] [Accepted: 09/16/2015] [Indexed: 12/17/2022]
Abstract
PURPOSE A 24-month prospective follow-up study was carried out to compare perioperative clinical outcomes, radiographic limb alignment, component positioning, as well as functional outcomes following total knee arthroplasty (TKA) between patient-specific instrumentation (PSI) and conventional instrumentation (CI). METHODS Ninety consecutive patients, satisfying the inclusion and exclusion criteria, were scheduled to undergo TKA with either PSI or CI. A CT-based PSI was used in this study, and a senior surgeon performed all surgeries. Patients were clinically and functionally assessed preoperatively, 6 and 24 months post-operatively. Perioperative outcomes were also analysed, including operating time, haemoglobin loss, the need for blood transfusion, length of hospitalisation, and radiographic features. RESULTS At 24-month follow-up, clinical and functional outcomes were comparable between the two groups. PSI performed no better than CI in restoring lower limb mechanical alignment or improving component positioning. There were no differences in operating time, haemoglobin loss, transfusion rate, or length of hospitalisation between PSI and CI. CONCLUSION No significant clinical benefit could be demonstrated in using PSI over CI after 24 months, and routine use of PSI is not recommended in non-complicated TKA. LEVEL OF EVIDENCE II.
Collapse
Affiliation(s)
- Meng Zhu
- Duke-NUS Graduate Medical School, 8 College Road, Singapore, 169857, Singapore.
| | - Jerry Yongqiang Chen
- Department of Orthopaedic Surgery, Singapore General Hospital, 20 College Road, Singapore, 169865, Singapore
| | - Hwei Chi Chong
- Department of Orthopaedic Surgery, Singapore General Hospital, 20 College Road, Singapore, 169865, Singapore
| | - Andy Khye Soon Yew
- Department of Orthopaedic Surgery, Singapore General Hospital, 20 College Road, Singapore, 169865, Singapore
| | - Leon Siang Shen Foo
- Island Orthopaedic Consultants, Mount Elizabeth Medical Centre, 3 Mount Elizabeth, Singapore, 228510, Singapore
| | - Shi-Lu Chia
- Department of Orthopaedic Surgery, Singapore General Hospital, 20 College Road, Singapore, 169865, Singapore
| | - Ngai Nung Lo
- Department of Orthopaedic Surgery, Singapore General Hospital, 20 College Road, Singapore, 169865, Singapore
| | - Seng Jin Yeo
- Department of Orthopaedic Surgery, Singapore General Hospital, 20 College Road, Singapore, 169865, Singapore
| |
Collapse
|
41
|
Wu XD, Xiang BY, Schotanus MGM, Liu ZH, Chen Y, Huang W. CT- versus MRI-based patient-specific instrumentation for total knee arthroplasty: A systematic review and meta-analysis. Surgeon 2017; 15:336-348. [PMID: 28756064 DOI: 10.1016/j.surge.2017.06.002] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2017] [Revised: 06/06/2017] [Accepted: 06/12/2017] [Indexed: 01/23/2023]
Abstract
BACKGROUND To determine whether computed tomography (CT) or magnetic resonance imaging (MRI) is more suitable for the patient-specific instrumentation (PSI) systems for total knee arthroplasty (TKA). METHODS PubMed, Embase, and the Cochrane Library were searched from inception to June 2016 for prospective comparative trials that compared CT- versus MRI-based PSI systems for TKA. Our predefined primary outcome was the outliers incidence of coronal overall limb alignment. RESULTS Six studies with a total of 336 knees meeting the eligibility criteria, and four trials were included in the meta-analysis. Compared with MRI-based PSI systems, CT-based PSI systems were associated with a higher outliers incidence of coronal overall limb alignment (risk ratio: 1.67; 95% confidence interval (CI): 1.03-2.72; P = 0.04), more angular errors of coronal overall limb alignment (mean difference (MD): 1.01°; 95% CI: 0.47-1.56; P = 0.0003), and longer operation time (MD: 5.02 min; 95% CI: 1.26-8.79; P = 0.009). While no significant differences in the coronal/sagittal alignment of the femoral/tibial component outliers, the angular errors of coronal overall limb alignment, the angular errors of the femoral/tibial component in coronal plane, or incidence of change of implant size of the femoral/tibial component were observed. CONCLUSIONS The current limited evidence suggests that MRI-based PSI systems exhibit higher accuracy for TKA regarding the coronal limb axis than CT-based PSI systems. However, well-designed studies comparing CT-versus MRI-based PSI systems for TKA are warrant to confirm these results before widespread use of this technique can be recommended.
Collapse
Affiliation(s)
- Xiang-Dong Wu
- Department of Orthopaedic Surgery, The First Affiliated Hospital of Chongqing Medical University, Chongqing, 400016, China; Evidence-Based Perioperative Medicine 07 Collaboration Group, China
| | - Bing-Yan Xiang
- Department of Orthopaedic Surgery, The First Affiliated Hospital of Chongqing Medical University, Chongqing, 400016, China; Department of Orthopaedic Surgery, The First People's Hospital of Zunyi City, Zunyi, 563000, Guizhou Province, China
| | - Martijn G M Schotanus
- Department of Orthopedics, Zuyderland Medical Center, Sittard-Geleen, 6162 BG, The Netherlands
| | - Zun-Han Liu
- Department of Orthopaedic Surgery, The First Affiliated Hospital of Chongqing Medical University, Chongqing, 400016, China
| | - Yu Chen
- Department of Orthopaedic Surgery, The First Affiliated Hospital of Chongqing Medical University, Chongqing, 400016, China
| | - Wei Huang
- Department of Orthopaedic Surgery, The First Affiliated Hospital of Chongqing Medical University, Chongqing, 400016, China.
| |
Collapse
|
42
|
Sciberras NC, Almustafa M, Smith BRK, Allen DJ, Picard F, Deakin AH. A randomized controlled trial to compare component placement in navigated total knee arthroplasty using original and streamlined registration processes. Arthroplast Today 2017; 3:111-117. [PMID: 28695183 PMCID: PMC5484974 DOI: 10.1016/j.artd.2016.07.002] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/15/2016] [Revised: 07/14/2016] [Accepted: 07/20/2016] [Indexed: 01/26/2023] Open
Abstract
Background This randomized controlled trial validated a redesigned version of navigated total knee arthroplasty software with a streamlined registration (Smart) against the previous version (Classic). The objectives were to determine if Smart software had the same accuracy of component positioning and whether registration and operative time were reduced. Methods A total of 220 patients were recruited and had a navigated total knee arthroplasty performed. With the exception of the software, all patients had the same perioperative care. At 6-week follow-up with an independent arthroplasty service, all patients had a computerized tomography scan. This was assessed by an independent radiologist to measure the mechanical alignment of the components. Results The mean postoperative mechanical femorotibial angles were equivalent between groups (mean difference −0.2°, 95% confidence interval −0.7° to 0.3°, P = .407). Component positions were similar in both groups. Mean registration time was significantly shorter for the Smart group (2 minutes 30 seconds ± 54 seconds) than the Classic group (3 minutes 23 seconds ± 39 seconds), P < .001. The mean operative time was 72 ± 12 minutes in both groups (P = .855). At 6-week follow-up, both groups had similar clinical outcomes with 96.5% of patients being satisfied or very satisfied. Conclusions The study verified that a reduced registration time did not alter the accuracy of component placement. However, despite a shorter registration time, the overall surgical time was not reduced.
Collapse
Affiliation(s)
- Nadia C Sciberras
- Department of Orthopaedics, Golden Jubilee National Hospital, Clydebank, Scotland, UK
| | - Mohammed Almustafa
- Department of Orthopaedics, Golden Jubilee National Hospital, Clydebank, Scotland, UK
| | - Benjamin R K Smith
- Department of Radiology, Gartnavel General Hospital, Glasgow, Scotland, UK
| | - David J Allen
- Department of Orthopaedics, Golden Jubilee National Hospital, Clydebank, Scotland, UK
| | - Frederic Picard
- Department of Orthopaedics, Golden Jubilee National Hospital, Clydebank, Scotland, UK
| | - Angela H Deakin
- Department of Orthopaedics, Golden Jubilee National Hospital, Clydebank, Scotland, UK
| |
Collapse
|
43
|
Postoperative alignment of TKA in patients with severe preoperative varus or valgus deformity: is there a difference between surgical techniques? BMC Musculoskelet Disord 2017. [PMID: 28637433 PMCID: PMC5480120 DOI: 10.1186/s12891-017-1628-8] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/28/2022] Open
Abstract
BACKGROUND There have been conflicting studies published regarding the ability of various total knee arthroplasty (TKA) techniques to correct preoperative deformity. The purpose of this study was to compare the postoperative radiographic alignment in patients with severe preoperative coronal deformity (≥10° varus/valgus) who underwent three different TKA techniques; manual instrumentation (MAN), computer navigated instrumentation (NAV) and patient specific instrumentation (PSI). METHODS Patients, who received a TKA with a preoperative coronal deformity of ≥10° with available radiographs were included in this retrospective study. The groups were: MAN; n = 54, NAV; n = 52 and PSI; n = 53. The mechanical axis (varus / valgus) and the posterior tibial slope were measured and analysed using standing long leg- and lateral radiographs. RESULTS The overall mean postoperative varus / valgus deformity was 2.8° (range, 0 to 9.9; SD 2.3) and 2.5° (range, 0 to 14.7; SD 2.3), respectively. The overall outliers (>3°) represented 30.2% (48 /159) of cases and were distributed as followed: MAN group: 31.5%, NAV group: 34.6%, PSI group: 24.4%. No significant statistical differences were found between these groups. The distribution of the severe outliers (>5°) was 14.8% in the MAN group, 23% in the NAV group and 5.6% in the PSI group. The PSI group had significantly (p = 0.0108) fewer severe outliers compared to the NAV group while all other pairs were not statistically significant. CONCLUSIONS In severe varus / valgus deformity the three surgical techniques demonstrated similar postoperative radiographic alignment. However, in reducing severe outliers (> 5°) and in achieving the planned posterior tibial slope the PSI technique for TKA may be superior to computer navigation and the conventional technique. Further prospective studies are needed to determine which technique is the best regarding reducing outliers in patients with severe preoperative coronal deformity.
Collapse
|
44
|
Dall'Oca C, Ricci M, Vecchini E, Giannini N, Lamberti D, Tromponi C, Magnan B. Evolution of TKA design. ACTA BIO-MEDICA : ATENEI PARMENSIS 2017; 88:17-31. [PMID: 28657559 PMCID: PMC6178992 DOI: 10.23750/abm.v88i2 -s.6508] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 06/01/2017] [Accepted: 06/01/2017] [Indexed: 11/23/2022]
Abstract
The use of Total Knee Arthroplasty (TKA) in treatment of chronic degenerative pathologies of the knee boasts of an experience of 50 years. During this period the collaboration between surgeons and engineers produced many developments in the design of the prosthesis. Today this procedure is safe and established even if in continuous development. The progress in technologies and the use of new materials let researches try again old-fashioned techniques from the past in order to be improved. This enthusiasm for those discovers is not always going hand to hand with scientific validation: many open questions remains Every different concept of the design tries to answer to special needs as the reach of the highest ROM, the reduction of pain and debris, articular geometry, the type of fixation, the modularity of augments and stems, the types of constraints, knee kinematic and of course costs.
Collapse
|
45
|
Tang Q, Shang P, Zheng G, Xu HZ, Liu HX. Extramedullary versus intramedullary femoral alignment technique in total knee arthroplasty: a meta-analysis of randomized controlled trials. J Orthop Surg Res 2017; 12:82. [PMID: 28583144 PMCID: PMC5460512 DOI: 10.1186/s13018-017-0582-3] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/18/2017] [Accepted: 05/21/2017] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND There is no consensus whether the use of the extramedullary femoral cutting guide takes advantage over the intramedullary one in total knee arthroplasty. The aim of this study was to compare the extramedullary femoral alignment guide system with the conventional intramedullary alignment guide system for lower limb alignment, blood loss, and operative time during total knee arthroplasty. METHODS The Medline, Embase, Cochrane Library, China National Knowledge Infrastructure (CNKI), Wan Fang Chinese Periodical, Google, and reference lists of all the included studies were searched for randomized controlled trials. The following parameters were compared between the extramedullary technique and the intramedullary technique: (1) lower limb coronal alignment, (2) coronal alignment of femoral component, (3) sagittal alignment of femoral component, (4) blood loss, (5) and operation time. RESULTS Four randomized controlled trials consisting of 358 knees were included in our study. There was no significant difference between the extramedullary and intramedullary groups for the lower limb coronal alignment (RR = 1.20, 95%CI 0.28~5.21, n.s.), coronal alignment of femoral component (RR = 0.65, 95%CI 0.19~2.22, n.s.), and sagittal alignment of femoral component (RR = 0.73, 95%CI 0.38~1.41, n.s.). A reduced blood loss was associated with the use of the extramedullary guide (MD = -120.34, 95%CI -210.08~-30.59, P = 0.009). No significant difference in operation time was noted between the two groups (MD = 1.41, 95%CI -1.82~4.64, n.s.). CONCLUSIONS Neither extramedullary nor intramedullary femoral alignment is more accurate than the other in facilitating the femoral cut in total knee arthroplasty. Use of the extramedullary guide results in less blood loss and exhibits a similar operation time as compared with the intramedullary guide.
Collapse
Affiliation(s)
- Qian Tang
- Department of Orthopaedic Surgery, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, 109, Xueyuanxi road, 325027, Wenzhou, China
| | - Ping Shang
- Department of Rehabilitation, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, 109 Xueyuanxi road, Wenzhou, 325027, China
| | - Gang Zheng
- Department of Orthopaedic Surgery, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, 109, Xueyuanxi road, 325027, Wenzhou, China
| | - Hua-Zi Xu
- Department of Orthopaedic Surgery, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, 109, Xueyuanxi road, 325027, Wenzhou, China
| | - Hai-Xiao Liu
- Department of Orthopaedic Surgery, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, 109, Xueyuanxi road, 325027, Wenzhou, China.
| |
Collapse
|
46
|
Calliess T, Bauer K, Stukenborg-Colsman C, Windhagen H, Budde S, Ettinger M. PSI kinematic versus non-PSI mechanical alignment in total knee arthroplasty: a prospective, randomized study. Knee Surg Sports Traumatol Arthrosc 2017; 25:1743-1748. [PMID: 27120192 DOI: 10.1007/s00167-016-4136-8] [Citation(s) in RCA: 139] [Impact Index Per Article: 19.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/10/2015] [Accepted: 04/14/2016] [Indexed: 10/21/2022]
Abstract
PURPOSE Kinematic alignment in TKA is supposed to restore function by aligning the components to the premorbid flexion-extension axis instead of altering the joint line and natural kinematic axes of the knee. The purpose of this study was to compare mechanically aligned TKA to kinematic alignment. METHODS In this study, 200 patients underwent TKA and were randomly assigned to 2 groups: 100 TKAs were performed using kinematic alignment with custom-made cutting guides in order to complete cruciate-retaining TKA; the other 100 patients underwent TKA that was manually performed using mechanical alignment. The WOMAC and combined Knee Society Score (KSS), as well as radiological alignment, were determined as outcome parameters at the 12-month endpoint. RESULTS WOMAC and KSS significantly improved in both groups. There was a significant difference in both scores between groups in favour of kinematic alignment. Although the kinematic alignment group demonstrated significantly better overall results, more outliers with poor outcomes were also seen in this group. A correlation between post-operative alignment deviation from the initial plan and poor outcomes was also noted. The most important finding of this study is that applying kinematic alignment in TKA achieves comparable results to mechanical alignment in TKA. This study also shows that restoring the premorbid flexion-extension axis of the knee joint leads to better overall functional results. CONCLUSION Kinematic alignment is a favourable technique for TKA. CLINICAL RELEVANCE The kinematic alignment idea might be a considerable alternative to mechanical alignment in the future. LEVEL OF EVIDENCE II.
Collapse
Affiliation(s)
- Tilman Calliess
- Department of Orthopedic Surgery, Hannover Medical School, Anna-v.Borries-Str.1-7, 30625, Hannover, Germany
| | - Kamil Bauer
- Department of Orthopedic Surgery, Hannover Medical School, Anna-v.Borries-Str.1-7, 30625, Hannover, Germany
| | | | - Henning Windhagen
- Department of Orthopedic Surgery, Hannover Medical School, Anna-v.Borries-Str.1-7, 30625, Hannover, Germany
| | - Stefan Budde
- Department of Orthopedic Surgery, Hannover Medical School, Anna-v.Borries-Str.1-7, 30625, Hannover, Germany
| | - Max Ettinger
- Department of Orthopedic Surgery, Hannover Medical School, Anna-v.Borries-Str.1-7, 30625, Hannover, Germany.
| |
Collapse
|
47
|
Thienpont E, Schwab PE, Fennema P. Efficacy of Patient-Specific Instruments in Total Knee Arthroplasty: A Systematic Review and Meta-Analysis. J Bone Joint Surg Am 2017; 99:521-530. [PMID: 28291186 DOI: 10.2106/jbjs.16.00496] [Citation(s) in RCA: 80] [Impact Index Per Article: 11.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Patient-specific instrumentation (PSI) was introduced with the aim of making the procedure of total knee arthroplasty more accurate and efficient. The purpose of this study was to compare PSI and standard instrumentation in total knee arthroplasty with regard to radiographic and clinical outcomes as well as operative time and blood loss. METHODS A meta-analysis was conducted in accordance with the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) statement. PubMed and Embase were searched from 2011 through 2015. We included randomized controlled trials and cohort studies that reported the effect of PSI on the aforementioned outcomes. The primary end point was deviation from the mechanical axis by >3°. Random and fixed-effect models were used for analysis. RESULTS A total of 44 studies, which included 2,866 knees that underwent surgery with PSI and 2,956 knees that underwent surgery with standard instrumentation, were evaluated. The risk of mechanical axis malalignment was significantly lower for PSI, with a pooled relative risk of 0.79 (p = 0.013). The risk of tibial sagittal-plane malalignment was higher for PSI than for standard instrumentation (relative risk = 1.32, p = 0.001), whereas the risk of femoral coronal-plane malalignment was significantly lower (relative risk = 0.74, p = 0.043). The risk of tibial coronal-plane malalignment was significantly higher for PSI only when employing fixed-effect meta-analysis (relative risk = 1.33, p = 0.042). Minor reductions in total operative time (-4.4 minutes, p = 0.002) and blood loss (-37.9 mL, p = 0.015) were noted for PSI. CONCLUSIONS PSI improves the accuracy of femoral component alignment and global mechanical alignment, but at the cost of an increased risk of outliers for the tibial component alignment. The impact of the increased probability of tibial component malalignment on implant longevity remains to be determined. Meta-analyses indicated significant differences with regard to operative time and blood loss in favor of PSI. However, these differences were minimal and, by themselves, not a substantial justification for routine use of the technology. LEVEL OF EVIDENCE Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Emmanuel Thienpont
- 1University Hospital Saint Luc, Brussels, Belgium 2AMR Advanced Medical Research, Männedorf, Switzerland
| | | | | |
Collapse
|
48
|
Yamamura K, Minoda Y, Mizokawa S, Ohta Y, Sugama R, Nakamura S, Ueyama H, Nakamura H. Novel alignment measurement technique for total knee arthroplasty using patient specific instrumentation. Arch Orthop Trauma Surg 2017; 137:401-407. [PMID: 28097422 DOI: 10.1007/s00402-017-2628-8] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/15/2016] [Indexed: 11/28/2022]
Abstract
INTRODUCTION This study was designed to evaluate the true accuracy of patient specific instrumentation (PSI) for total knee arthroplasty (TKA) using a new 3D measurement method. MATERIALS AND METHODS Consecutive 21 patients (30 knees) who underwent TKA using computed tomography (CT)-based PSI were retrospectively evaluated. Mean patient age was 69.2 years (62 to 77). The postoperative three-dimensional (3D) CT image were superimposed onto the preoperative 3D CT plan and measured the absolute difference in the prosthetic alignment using six parameters: coronal, sagittal, and axial alignment of the femoral and tibial prostheses. Cases in which the difference in the prosthetic alignment was greater than 3° were considered outliers. RESULTS For the femoral prosthesis, mean absolute differences between the preoperative 3D CT plan and postoperative 3D CT image were not significantly different and the rates of outliers were 10.0, 33.3, 23.3% in the coronal, sagittal, and axial planes. For the tibial prosthesis, mean absolute differences were significantly larger in the axial plane than in the coronal and sagittal planes (p < 0.001) and the rates of outliers were 23.3, 36.7, 63.3% in the coronal, sagittal, and axial planes. The rates of outliers for the axial alignment of tibial prosthesis were significantly higher than for the other five planes (p = 0.006). CONCLUSIONS The rotation of the tibial prosthesis with CT-based PSI was less accurate in the axial plane than in the other five planes.
Collapse
Affiliation(s)
- Kazumasa Yamamura
- Department of Orthopaedic Surgery, Osaka City University Graduate School of Medicine, 1-4-3 Asahi-machi Abeno-ku, Osaka, 545-8585, Japan
| | - Yukihide Minoda
- Department of Orthopaedic Surgery, Osaka City University Graduate School of Medicine, 1-4-3 Asahi-machi Abeno-ku, Osaka, 545-8585, Japan.
| | - Shigekazu Mizokawa
- Department of Orthopaedic Surgery, Osaka City University Graduate School of Medicine, 1-4-3 Asahi-machi Abeno-ku, Osaka, 545-8585, Japan
| | - Yoichi Ohta
- Department of Orthopaedic Surgery, Osaka City University Graduate School of Medicine, 1-4-3 Asahi-machi Abeno-ku, Osaka, 545-8585, Japan
| | - Ryo Sugama
- Department of Orthopaedic Surgery, Osaka City University Graduate School of Medicine, 1-4-3 Asahi-machi Abeno-ku, Osaka, 545-8585, Japan
| | - Suguru Nakamura
- Department of Orthopaedic Surgery, Osaka City University Graduate School of Medicine, 1-4-3 Asahi-machi Abeno-ku, Osaka, 545-8585, Japan
| | - Hideki Ueyama
- Department of Orthopaedic Surgery, Osaka City University Graduate School of Medicine, 1-4-3 Asahi-machi Abeno-ku, Osaka, 545-8585, Japan
| | - Hiroaki Nakamura
- Department of Orthopaedic Surgery, Osaka City University Graduate School of Medicine, 1-4-3 Asahi-machi Abeno-ku, Osaka, 545-8585, Japan
| |
Collapse
|
49
|
Huijbregts HJTAM, Khan RJK, Fick DP, Hall MJ, Punwar SA, Sorensen E, Reid MJ, Vedove SD, Haebich S. Component alignment and clinical outcome following total knee arthroplasty: a randomised controlled trial comparing an intramedullary alignment system with patient-specific instrumentation. Bone Joint J 2017; 98-B:1043-9. [PMID: 27482015 DOI: 10.1302/0301-620x.98b8.37240] [Citation(s) in RCA: 44] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/11/2015] [Accepted: 04/04/2016] [Indexed: 11/05/2022]
Abstract
AIMS We conducted a randomised controlled trial to assess the accuracy of positioning and alignment of the components in total knee arthroplasty (TKA), comparing those undertaken using standard intramedullary cutting jigs and those with patient-specific instruments (PSI). PATIENTS AND METHODS There were 64 TKAs in the standard group and 69 in the PSI group. The post-operative hip-knee-ankle (HKA) angle and positioning was investigated using CT scans. Deviation of > 3° from the planned position was regarded as an outlier. The operating time, Oxford Knee Scores (OKS) and Short Form-12 (SF-12) scores were recorded. RESULTS There were 14 HKA-angle outliers (22%) in the standard group and nine (13%) in the PSI group (p = 0.251). The mean HKA-angle was 0.5° varus in the standard group and 0.2° varus in the PSI group (p = 0.492). The accuracy of alignment in the coronal and axial planes and the proportion of outliers was not different in the two groups. The femoral component was more flexed (p = 0.035) and there were significantly more tibial slope outliers (29% versus 13%) in the PSI group (p = 0.032). Operating time and the median three-month OKS were similar (p = 0.218 and p = 0.472, respectively). Physical and mental SF-12 scores were not significantly different at three months (p = 0.418 and p = 0.267, respectively) or at one year post-operatively (p = 0.114 and p = 0.569). The median one-year Oxford knee score was two points higher in the PSI group (p = 0.049). CONCLUSION Compared with standard intramedullary jigs, the use of PSI did not significantly reduce the number of outliers or the mean operating time, nor did it clinically improve the accuracy of alignment or the median Oxford Knee Scores. Our data do not support the routine use of PSI when undertaking TKA. Cite this article: Bone Joint J 2016;98-B:1043-9.
Collapse
Affiliation(s)
- H J T A M Huijbregts
- The Joint Studio, Hollywood Medical Centre, 1/85 Monash Ave, Nedlands, WA, Australia
| | - R J K Khan
- The Joint Studio, Hollywood Medical Centre, 85 Monash Avenue, Nedlands, WA 6009, Australia
| | - D P Fick
- The Joint Studio, Hollywood Medical Centre, 85 Monash Avenue, Nedlands, WA 6009, Australia
| | - M J Hall
- The Joint Studio, Hollywood Medical Centre, 85 Monash Avenue, Nedlands, WA 6009, Australia
| | - S A Punwar
- The Joint Studio, Hollywood Medical Centre, 85 Monash Avenue, Nedlands, WA 6009, Australia
| | - E Sorensen
- Geraldton Regional Hospital, 51-85 Shenton Street, Geraldton WA 6530, Australia
| | - M J Reid
- The Joint Studio, Hollywood Medical Centre, 85 Monash Avenue, Nedlands, WA 6009, Australia
| | - S Dalle Vedove
- Geraldton Radiology, Hermitage Street, Geraldton, WA 6530, Australia
| | - S Haebich
- The Joint Studio, Hollywood Medical Centre, 85 Monash Avenue, Nedlands, WA 6009, Australia
| |
Collapse
|
50
|
Hamid KS, Matson AP, Nwachukwu BU, Scott DJ, Mather RC, DeOrio JK. Determining the Cost-Savings Threshold and Alignment Accuracy of Patient-Specific Instrumentation in Total Ankle Replacements. Foot Ankle Int 2017; 38:49-57. [PMID: 27649973 DOI: 10.1177/1071100716667505] [Citation(s) in RCA: 31] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Traditional intraoperative referencing for total ankle replacements (TARs) involves multiple steps and fluoroscopic guidance to determine mechanical alignment. Recent adoption of patient-specific instrumentation (PSI) allows for referencing to be determined preoperatively, resulting in less steps and potentially decreased operative time. We hypothesized that usage of PSI would result in decreased operating room time that would offset the additional cost of PSI compared with standard referencing (SR). In addition, we aimed to compare postoperative radiographic alignment between PSI and SR. METHODS Between August 2014 and September 2015, 87 patients undergoing TAR were enrolled in a prospectively collected TAR database. Patients were divided into cohorts based on PSI vs SR, and operative times were reviewed. Radiographic alignment parameters were retrospectively measured at 6 weeks postoperatively. Time-driven activity-based costing (TDABC) was used to derive direct costs. Cost vs operative time-savings were examined via 2-way sensitivity analysis to determine cost-saving thresholds for PSI applicable to a range of institution types. Cost-saving thresholds defined the price of PSI below which PSI would be cost-saving. A total of 35 PSI and 52 SR cases were evaluated with no significant differences identified in patient characteristics. RESULTS Operative time from incision to completion of casting in cases without adjunct procedures was 127 minutes with PSI and 161 minutes with SR ( P < .05). PSI demonstrated similar postoperative accuracy to SR in coronal tibial-plafond alignment (1.1 vs 0.3 degrees varus, P = .06), tibial-plafond alignment (0.3 ± 2.1 vs 1.1 ± 2.1 degrees varus, P = .06), and tibial component sagittal alignment (0.7 vs 0.9 degrees plantarflexion, P = .14). The TDABC method estimated a PSI cost-savings threshold range at our institution of $863 below which PSI pricing would provide net cost-savings. Two-way sensitivity analysis generated a globally applicable cost-savings threshold model based on institution-specific costs and surgeon-specific time-savings. CONCLUSIONS This study demonstrated equivalent postoperative TAR alignment with PSI and SR referencing systems but with a significant decrease in operative time with PSI. Based on TDABC and associated sensitivity analysis, a cost-savings threshold of $863 was identified for PSI pricing at our institution below which PSI was less costly than SR. Similar internal cost accounting may benefit health care systems for identifying cost drivers and obtaining leverage during price negotiations. LEVEL OF EVIDENCE Level III, therapeutic study.
Collapse
|