1
|
Reappraisal of the proximal tibia anatomy in Turkish population. Surg Radiol Anat 2023; 45:263-270. [PMID: 36719430 DOI: 10.1007/s00276-023-03094-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2022] [Accepted: 01/23/2023] [Indexed: 02/01/2023]
Abstract
OBJECTIVE Total knee arthroplasty has been popular in recent years. Morphometry of proximal tibia is important for surgeons to perform successful total knee arthroplasty. Aim of this study was to reappraise the proximal tibia morphometry. METHODS In this study, 57 human dry tibia were evaluated. Anteroposterior and mediolateral dimensions of tibial condyles, maximum width of superior articular surface and length of tibia were measured. Furthermore, morphometric measurements of the intercondylar area and Gerdy's tubercle (infracondylar tibial tubercle) were done. All measurements were performed by two observers using a digital caliper. RESULTS Mean anteroposterior and mediolateral dimensions of medial tibial condyle were found 39.76 and 23.27 mm, respectively. Mean anteroposterior and mediolateral dimensions of lateral tibial condyle were measured 34.72 and 21.83 mm, respectively. Mean anteroposterior dimension of intercondylar area was 41.62 mm. Shape of the Gerdy's tubercle was oval in 76.8%, irregular in 12.5%, and triangular in 10.7%. Texture of the tubercle was smooth in 85.7% and rough in 14.3%. Mean superoinferior and mediolateral dimensions of Gerdy's tubercle were 12.28 and 10.27 mm, respectively. Anteroposterior and mediolateral dimensions of tibial condyles were significantly higher (p < 0.05) for the medial condyle. Positive and statistically significant correlations were found between the tibial length and the other parameters (p < 0.05, r > 0.40). CONCLUSION The morphometric data of tibial plateau are important for surgeons during total knee arthroplasty. The superoinferior and mediolateral dimensions of the Gerdy's tubercle, the distance between Gerdy's tubercle and tibial tuberosity, the distance between Gerdy's tubercle and lateral tibial plateau were measured for the first time in our study. The data obtained from this study can be used as a guideline in designing tibial component of the total knee prosthesis in Turkish population. In arthroplasty, patient-specific prosthetic implants may eradicate implant mismatch in the near future.
Collapse
|
2
|
Lack of small tibial component size availability for females in a highly utilized total knee arthroplasty system. Knee Surg Sports Traumatol Arthrosc 2021; 29:3164-3169. [PMID: 32533222 DOI: 10.1007/s00167-020-06082-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/21/2020] [Accepted: 05/22/2020] [Indexed: 11/27/2022]
Abstract
PURPOSE Surgeons must rely on manufacturers to provide an appropriate distribution of total knee arthroplasty (TKA) sizes. There is a lack of literature regarding current appropriateness of tibial sizing schemes according to sex. As such, a study was devised assessing the adequacy of off-the-shelf tibial component size availability according to sex. METHODS A search was conducted to identify all primary TKAs between July 2012 and June 2019 performed using a single implant. Baseline patient characteristics were collected (age, weight, height, BMI, and race). Two cohorts were created according to patient sex. Tibial sizes for each cohort were collected. Tibial component bar graph and histogram were created according to component sizes. Skewness and kurtosis were calculated for each distribution. Overhang was noted and measured radiographically. RESULTS A total of 864 patients were identified, 38.7% males and 61.3% females. Most patients were Caucasian, and BMI was similar between cohorts. Tibial size distribution for males was as follows: 0.3% C, 4.8% D, 16.5% E, 40.1% F, 31.4% G, 6.9% H. Tibial size distribution for females was as follows: 30.8% C, 42.8% D, 23.0% E, 2.6% F, 0.8% G, 0.0% H. Histograms and normal curves demonstrated a fairly symmetric distribution of sizes for males (skewness = - 0.31, kurtosis = - 0.03). The distribution for females was positively skewed (skewness = 0.57, kurtosis = 0.12). Overall, overhang was noted in 16.6% of all size C tibias. CONCLUSIONS The results of this study highlight an implant-specific discrepancy in size availability affecting female patients which could result in inferior outcomes. The authors urge manufacturers to critically assess current implant size distribution availability to ensure both genders are adequately, and equally represented. LEVEL OF EVIDENCE IV.
Collapse
|
3
|
Budhiparama NC, Lumban-Gaol I, Ifran NN, de Groot PCJ, Utomo DN, Nelissen RGHH. Mismatched knee implants in Indonesian and Dutch patients: a need for increasing the size. Knee Surg Sports Traumatol Arthrosc 2021; 29:358-369. [PMID: 32162046 DOI: 10.1007/s00167-020-05914-9] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/21/2019] [Accepted: 02/21/2020] [Indexed: 10/24/2022]
Abstract
PURPOSE The aim of this study was to evaluate the anthropometric differences between knees of Indonesian Asians and Dutch Caucasians and the fit of nine different knee implant systems. METHODS A total of 268 anteroposterior (AP) and lateral knee preoperative radiographs from 134 consecutive patients scheduled for total knee arthroplasty at two different centres in Jakarta and Leiden were included. Both patient groups were matched according to age and sex and included 67 Asians and 67 Caucasians. We assessed the radiographic differences between the Asian and Caucasian anthropometric data. The dimensions of the nine knee implant designs (Vanguard, Genesis II, Persona Standard, Persona Narrow, GK Sphere, Gemini, Attune Standard, Attune Narrow, and Sigma PFC) were compared with the patients' anthropometric (distal femur and proximal tibia) measurements. RESULTS The Dutch Caucasian patients had larger mediolateral (ML) and AP femoral and tibial dimensions than the Indonesian Asians. The aspect ratios of the distal femur and tibia were larger in Asians than in Caucasians. The AP and ML dimensions were mismatched between the tibial components of the nine knee systems and the Asian anthropometric data. Both groups had larger ML distal femoral dimensions than the knee systems. CONCLUSION Absolute and relative differences in knee dimensions exist not only between Asian and Caucasian knees but also within both groups. Not all TKA systems had a good fit with the Asian and Caucasian knee phenotypes. An increase in the range of available knee component sizes would be beneficial, although TKA remains an adequate compromise. LEVEL OF EVIDENCE III.
Collapse
Affiliation(s)
- Nicolaas C Budhiparama
- Nicolaas Institute of Constructive Orthopaedic Research and Education Foundation for Arthroplasty and Sports Medicine, Medistra Hospital, Jl. Jend. Gatot Subroto Kav. 59, Jakarta, 12950, Indonesia. .,Department of Orthopaedics and Traumatology, School of Medicine, University of Airlangga, Jl. Mayjend. Prof. Dr. Moestopo 6-8, Surabaya, 60286, Indonesia. .,Department of Orthopaedics, Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, The Netherlands.
| | - Imelda Lumban-Gaol
- Nicolaas Institute of Constructive Orthopaedic Research and Education Foundation for Arthroplasty and Sports Medicine, Medistra Hospital, Jl. Jend. Gatot Subroto Kav. 59, Jakarta, 12950, Indonesia
| | - Nadia Nastassia Ifran
- Nicolaas Institute of Constructive Orthopaedic Research and Education Foundation for Arthroplasty and Sports Medicine, Medistra Hospital, Jl. Jend. Gatot Subroto Kav. 59, Jakarta, 12950, Indonesia
| | - Pieter C J de Groot
- Department of Orthopaedics, Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, The Netherlands
| | - Dwikora Novembri Utomo
- Department of Orthopaedics and Traumatology, School of Medicine, University of Airlangga, Jl. Mayjend. Prof. Dr. Moestopo 6-8, Surabaya, 60286, Indonesia
| | - Rob G H H Nelissen
- Department of Orthopaedics, Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, The Netherlands
| |
Collapse
|
4
|
Beckmann J, Meier MK, Benignus C, Hecker A, Thienpont E. Contemporary knee arthroplasty: one fits all or time for diversity? Arch Orthop Trauma Surg 2021; 141:2185-2194. [PMID: 34269891 PMCID: PMC8595166 DOI: 10.1007/s00402-021-04042-4] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/12/2021] [Accepted: 07/01/2021] [Indexed: 11/24/2022]
Abstract
INTRODUCTION Total knee arthroplasty (TKA) has historically been the preferred solution for any type of knee osteoarthritis, independently of the number of compartments involved. In these days of patient-specific medicine, mono-compartmental disease could also be approached with a more individualized treatment, such as partial knee arthroplasty (PKA). Off-the-shelf (OTS) implants are often the compromise of averages and means of a limited series of anatomical parameters retrieved from patients and the pressure of cost control by limited inventory. Personalized medicine requires respect and interest for the individual shape and alignment of each patient. MATERIALS AND METHODS A Pubmed and Google Scholar search were performed with the following terms: "patient-specific knee" and "arthroplasty" and "custom implant" and "total knee replacement" and "partial knee replacement" and "patellofemoral knee replacement" and "bicompartmental knee replacement". The full text of 90 articles was used to write this narrative review. RESULTS Unicondylar, patellofemoral and bicompartmental knee arthroplasty are successful treatment options, which can be considered over TKA for their bone and ligament sparing character and the superior functional outcome that can be obtained with resurfacing procedures. For TKA, where compromises dominate our choices, especially in patients with individual variations of their personal anatomy outside of the standard, a customized implant could be a preferable solution. CONCLUSION TKA might not be the only solution for every patient with knee osteoarthritis, if personalized medicine wants to be offered. Patient-specific mono-compartmental resurfacing solutions, such as partial knee arthroplasty, can be part of the treatment options proposed by the expert surgeon. Customized implants and personalized alignment options have the potential to further improve clinical outcome by identifying the individual morphotype and respecting the diversity of the surgical population.
Collapse
Affiliation(s)
- Johannes Beckmann
- Department of Endoprosthetics, Sportklinik Stuttgart, Stuttgart, Germany
| | - Malin Kristin Meier
- Department of Orthopedic Surgery and Traumatology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
| | - Christian Benignus
- Department of Endoprosthetics, Sportklinik Stuttgart, Stuttgart, Germany
| | - Andreas Hecker
- Department of Orthopedic Surgery and Traumatology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | | |
Collapse
|
5
|
Marino D, Patel J, Popovich JM, Cochran J. Patient Demographics and Anthropometric Measurements Predict Tibial and Femoral Component Sizing in Total Knee Arthroplasty. Arthroplast Today 2020; 6:860-865. [PMID: 33163600 PMCID: PMC7606840 DOI: 10.1016/j.artd.2020.09.013] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/12/2020] [Revised: 09/09/2020] [Accepted: 09/29/2020] [Indexed: 01/28/2023] Open
Abstract
Background Accurate sizing is critical for the overall success of a total knee arthroplasty (TKA). This study's primary purpose was to investigate the ability to predict the tibial and femoral component size in a single implant system from patient demographics and anthropometric data. A secondary goal was to compare the predicted tibial and femoral component sizes from our statistical model with a previously validated electronic application used to predict the implant size. Methods A consecutive series of 484 patients undergoing a primary TKA at a single institution was reviewed. Data on height, weight, body mass index, sex, age, and component size were collected. A proportional odds model was developed to predict tibial and femoral component sizes. The relationship between the proportional odds model predictions was also compared with the component sizes determined by the Arthroplasty Size Predictor electronic application. Results Weight, height, and sex predicted the implanted component size with an accuracy of 54.0% (n = 247/484) for the tibia and 51.1% (n = 231/484) for the femur. The accuracy improved to 94.4% (n = 457/484) for the tibia and 93.4% (n = 452/484) for the femur within ±1 component size. Our data are highly correlated to the Arthroplasty Size Predictor for the predicted tibial component size (ρ = 0.91, P < .001) and femoral component size (ρ = 0.89, P < .001). Conclusions Our novel templating model may improve operative efficiency for a single TKA system. Our findings have a high concordance with a widely available electronic application used to predict implant sizes for a variety of TKA systems.
Collapse
Affiliation(s)
- Dominic Marino
- Department of Orthopedic Surgery, McLaren-Greater Lansing Hospital, Lansing, MI, USA.,Department of Osteopathic Surgical Specialties, Michigan State University, East Lansing, MI, USA.,Department of Orthopedic Surgery, Sparrow Hospital, Lansing, MI, USA
| | - Jay Patel
- Department of Orthopedic Surgery, McLaren-Greater Lansing Hospital, Lansing, MI, USA.,Department of Osteopathic Surgical Specialties, Michigan State University, East Lansing, MI, USA.,Department of Orthopedic Surgery, Sparrow Hospital, Lansing, MI, USA
| | - John M Popovich
- Department of Orthopedic Surgery, Sparrow Hospital, Lansing, MI, USA.,Michigan State University Center for Orthopedic Research, East Lansing, MI, USA
| | - Jason Cochran
- Department of Orthopedic Surgery, McLaren-Greater Lansing Hospital, Lansing, MI, USA.,Department of Osteopathic Surgical Specialties, Michigan State University, East Lansing, MI, USA.,Department of Orthopedic Surgery, Sparrow Hospital, Lansing, MI, USA
| |
Collapse
|
6
|
Irzhanski AA, Kulyaba TA, Kornilov NN. VALIDATION AND CROSS-CULTURAL ADAPTATION OF RATING SYSTEMS WOMAC, KSS AND FJS-12 IN PATIENTS WITH KNEE DISORDERS AND INJURIES. TRAUMATOLOGY AND ORTHOPEDICS OF RUSSIA 2018. [DOI: 10.21823/2311-2905-2018-24-2-70-79] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
The purposeof the work — is validation and cultural adaptation of the english-language rating systems for knee function assessment for use in scientific, medical and educational institutions of the Russian Federation.Materials and Methods.The english versions of rating systems WOMac® 3.1 Index, The knee Society clinical Rating System©, FjS-12® were translated to Russian language by orthopedic surgeon with advanced level of english and the professional translator specializing in the translation of medical texts. Reverse translation was provided by third independent translator born in the english-speaking country (native speaker). a printed version of the various translations of the questionnaires was filled by patients with an interval of two days. The study group included 150 patients with Stage III knee osteoarthritis (90 women and 60 men aged 48 to 75 years, an average of 62.5 years) hospitalized in Vreden Research Institute of Traumatology and Orthopedics from February to april 2017 for total knee arthroplasty.Results.good and very good retest reliability of WOMac (α = 0.87 and α = 0.9), kSS (α = 0.89 and α = 0.86) and FjS-12 (α = 0.94 and α = 0.96) was revealed. The study revealed a strong correlation between the results of the questionnaires performed by different translators: WOMac (Icc = 0.89), kSS (Icc = 0.86), FjS-12 (Icc = 0.92). The correlation dependence between subsections of WOMac (stiffness – Icc = 0.98, pain – Icc = 0.87, daily functions – Icc = 0.89) and kSS (knee score – Icc = 0.94, function score – Icc = 0.88), which indicates a good constructive validity.Conclusion. The results of the study of criterial and constructive validity, as well as the retest reliability of the Russian versions of the WOMac, kSS and FjS-12 scales, indicate that they are a reliable and sensitive tool for assessing the function of knee joint, which can be widely used by Russian researchers in practical and scientific activities.
Collapse
|
7
|
Erkocak OF, Kucukdurmaz F, Sayar S, Erdil ME, Ceylan HH, Tuncay I. Anthropometric measurements of tibial plateau and correlation with the current tibial implants. Knee Surg Sports Traumatol Arthrosc 2016; 24:2990-2997. [PMID: 25906912 DOI: 10.1007/s00167-015-3609-5] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/28/2014] [Accepted: 04/16/2015] [Indexed: 10/23/2022]
Abstract
PURPOSE The aim of the study was to make an anthropometric analysis at the resected surfaces of the proximal tibia in the Turkish population and to compare the data with the dimensions of tibial components in current use. We hypothesized that tibial components currently available on the market do not fulfil the requirements of this population and a new tibial component design may be required, especially for female patients with small stature. METHODS Anthropometric data from the proximal tibia of 226 knees in 226 Turkish subjects were measured using magnetic resonance imaging. We measured the mediolateral, middle anteroposterior, medial and lateral anteroposterior dimensions and the aspect ratio of the resected proximal tibial surface. All morphological data were compared with the dimensions of five contemporary tibial implants, including asymmetric and symmetric design types. RESULTS The dimensions of the tibial plateau of Turkish knees demonstrated significant differences according to gender (P < 0.05). Among the different tibial implants reviewed, neither asymmetric nor symmetric designs exhibited a perfect conformity to proximal tibial morphology in size and shape. The vast majority of tibial implants involved in this study tend to overhang anteroposteriorly, and a statistically significant number of women (21 %, P < 0.05) had tibial anteroposterior diameters smaller than the smallest available tibial component. CONCLUSION Tibial components designed according to anthropometric measurements of Western populations do not perfectly meet the requirements of Turkish population. These data could provide the basis for designing the optimal and smaller tibial component for this population, especially for women, is required for best fit. LEVEL OF EVIDENCE II.
Collapse
Affiliation(s)
- Omer Faruk Erkocak
- Department of Orthopaedic Surgery and Traumatology, Faculty of Medicine, Selcuk University, Konya, 42075, Turkey.
| | - Fatih Kucukdurmaz
- Department of Orthopedic Surgery and Traumatology, Faculty of Medicine, BezmialemVakif University, Istanbul, Turkey
| | - Safak Sayar
- Department of Orthopedic Surgery and Traumatology, Faculty of Medicine, BezmialemVakif University, Istanbul, Turkey
| | - Mehmet Emin Erdil
- Department of Orthopedic Surgery and Traumatology, Faculty of Medicine, BezmialemVakif University, Istanbul, Turkey
| | - Hasan Huseyin Ceylan
- Department of Orthopedic Surgery and Traumatology, Faculty of Medicine, BezmialemVakif University, Istanbul, Turkey
| | - Ibrahim Tuncay
- Department of Orthopedic Surgery and Traumatology, Faculty of Medicine, BezmialemVakif University, Istanbul, Turkey
| |
Collapse
|
8
|
Beal MD, Delagramaticas D, Fitz D. Improving outcomes in total knee arthroplasty-do navigation or customized implants have a role? J Orthop Surg Res 2016; 11:60. [PMID: 27216272 PMCID: PMC4877731 DOI: 10.1186/s13018-016-0396-8] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/23/2016] [Accepted: 05/07/2016] [Indexed: 01/15/2023] Open
Abstract
Modern total knee arthroplasty is effective at treating the pain and disability associated with osteoarthritis. The number of total knee replacements done in the USA continues to increase. Despite the great care taken during all of these procedures, some patients remain dissatisfied with their outcome. While this dissatisfaction is likely multifactorial, malalignment of the prosthetic components is a major cause of postoperative complications. A neutral mechanical axis plus or minus 3° is felt to have a positive impact on the survivorship of the prosthesis. Conventional instrumentation has been shown to have a significant number of total knee replacements that lie well outside a neutral coronal alignment. With that in mind, significant effort has been placed into the development of technology to improve the overall alignment of the prosthesis. In order to reduce the number of outliers, several companies have developed cost-effective systems to aid the surgeon in achieving a more predictably aligned prosthesis in all three planes. We will review the literature that is available regarding several of these tools to examine if navigation or custom guides improve outcomes in total knee arthroplasty. Our review supports that while both navigation and custom implants guides seem to be a cost effective way to achieve a predictable mechanical alignment of a total knee prosthesis therefore reducing the number of outliers, the cost may be increased operative times with no perceived difference in patient satisfaction with navigation custom guides.
Collapse
Affiliation(s)
- Matthew D Beal
- Northwestern University Feinberg School of Medicine, Chicago, USA.
| | | | - David Fitz
- Northwestern University Feinberg School of Medicine, Chicago, USA
| |
Collapse
|