1
|
Hosseini Nasab SH, Smith CR, Postolka B, Schütz P, List R, Taylor WR. In Vivo Elongation Patterns of the Collateral Ligaments in Healthy Knees During Functional Activities. J Bone Joint Surg Am 2021; 103:1620-1627. [PMID: 33848100 DOI: 10.2106/jbjs.20.01311] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Improved knowledge of in vivo function of the collateral ligaments is essential for enhancing rehabilitation and guiding surgical reconstruction as well as soft-tissue balancing in total knee arthroplasty. The aim of this study was to quantify in vivo elongation patterns of the collateral ligaments throughout complete cycles of functional activities. METHODS Knee kinematics were measured using radiographic images captured with a mobile fluoroscope while healthy subjects performed level walking, downhill walking, and stair descent. The registered in vivo tibiofemoral kinematics were then used to drive subject-specific multibody knee models to track collateral ligament elongation. RESULTS The elongation patterns of the medial collateral ligament varied distinctly among its bundles, ranging from lengthening of the anterior fibers to shortening of the posterior bundle with increases in the knee flexion angle. The elongation patterns of the lateral collateral ligament varied considerably among subjects. It showed an average 4% shortening with increasing flexion until 60% to 70% of the gait cycle, and then recovered during the terminal-swing phase until reaching its reference length (defined at heel strike). CONCLUSIONS The observed nonuniform elongation of the medial collateral ligament bundles suggests that single-bundle reconstruction techniques may not fully restore healthy ligament function. Moreover, the observed ligament elongation patterns indicate greater varus than valgus laxity in the loaded knee. CLINICAL RELEVANCE Through providing key knowledge about the in vivo elongation patterns of the collateral ligaments throughout complete cycles of functional activities, this study offers in vivo evidence for benchmarking ligament reconstruction and soft-tissue balancing in total knee arthroplasty.
Collapse
Affiliation(s)
- S H Hosseini Nasab
- Laboratory for Movement Biomechanics, Institute for Biomechanics, ETH Zürich, Zürich, Switzerland
| | - C R Smith
- Laboratory for Movement Biomechanics, Institute for Biomechanics, ETH Zürich, Zürich, Switzerland
| | - B Postolka
- Laboratory for Movement Biomechanics, Institute for Biomechanics, ETH Zürich, Zürich, Switzerland
| | - P Schütz
- Laboratory for Movement Biomechanics, Institute for Biomechanics, ETH Zürich, Zürich, Switzerland
| | - R List
- Laboratory for Movement Biomechanics, Institute for Biomechanics, ETH Zürich, Zürich, Switzerland.,Human Performance Lab, Schulthess Clinic, Zürich, Switzerland
| | - W R Taylor
- Laboratory for Movement Biomechanics, Institute for Biomechanics, ETH Zürich, Zürich, Switzerland
| |
Collapse
|
2
|
Wang W, Tsai T, Tian F, Li J, Zhao Y, Zhu R, Li J, Liu Y, Wang S. High-speed fluoroscopic imaging for investigation of three-dimensional knee kinematics before and after marathon running. Gait Posture 2021; 88:231-237. [PMID: 34119778 DOI: 10.1016/j.gaitpost.2021.06.006] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/05/2021] [Revised: 05/11/2021] [Accepted: 06/06/2021] [Indexed: 02/02/2023]
Abstract
BACKGROUND Knee injuries often occur during or shortly after marathon running, and are linked to altered knee kinematics. RESEARCH QUESTION The kinematics of healthy knees during pre- and post-marathon running have not been examined with high-speed fluoroscopy. This study aimed to evaluate the effects of marathon running on knee kinematics during walking and running by using a combined high-speed fluoroscopy and MRI technique. METHODS Ten healthy runners underwent knee MRI within 24 h before marathon running to construct three-dimensional (3D) knee models. Knee kinematics during treadmill walking and running were evaluated using high-speed fluoroscopy (200hz) within 24 h before and as soon as possible (within 5 h) after marathon running. All pre- and post-marathon measurements were compared. RESULTS (1) For post-marathon walking, posterior femoral translation increased 1.4 mm at initial contact (p = 0.015); proximal-distal distance of tibia and femur decreased 0.7 mm and 0.8 mm at initial contact and after contact, respectively (p = 0.039, p = 0.046); and valgus femur rotation increased 1.2° after contact (p = 0.027). (2) For post-marathon running, proximal-distal distance decreased 0.7 mm and 1.0 mm at initial contact and after contact (p = 0.011, p = 0.003) respectively; knee flexion decreased 4.3° before contact (p = 0.007); knee flexion increased 1.8° and 2.6° at initial contact and after contact, respectively (p = 0.038, p = 0.011); external femoral rotation increased 1.2° and 1.8° at initial contact and after contact, respectively (p = 0.012, p = 0.037). Valgus femoral rotation after contact increased 2.3° (p = 0.001). SIGNIFICANCE Post-marathon changes in valgus and external femoral rotation, knee flexion, posterior femoral translation, and proximal-distal distance may increase the risk of knee injury. This study provides information to better understand the response of the knee to marathon running.
Collapse
Affiliation(s)
- Wenjin Wang
- Key Laboratory of Exercise and Health Sciences of Ministry of Education, School of Kinesiology, Shanghai University of Sport, Shanghai, China
| | - TsungYuan Tsai
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, 200240, China
| | - Fei Tian
- Key Laboratory of Exercise and Health Sciences of Ministry of Education, School of Kinesiology, Shanghai University of Sport, Shanghai, China; Department of Rehabilitation Medicine, Heping Hospital Affiliated to Changzhi Medical College, Shanxi, 046000, China
| | - Jixin Li
- Key Laboratory of Exercise and Health Sciences of Ministry of Education, School of Kinesiology, Shanghai University of Sport, Shanghai, China
| | - Yaqi Zhao
- Key Laboratory of Exercise and Health Sciences of Ministry of Education, School of Kinesiology, Shanghai University of Sport, Shanghai, China
| | - Renkun Zhu
- China Basketball College, Beijing Sport University, Beijing, 100048, China
| | - Junjie Li
- Key Laboratory of Exercise and Health Sciences of Ministry of Education, School of Kinesiology, Shanghai University of Sport, Shanghai, China
| | - Yu Liu
- Key Laboratory of Exercise and Health Sciences of Ministry of Education, School of Kinesiology, Shanghai University of Sport, Shanghai, China
| | - Shaobai Wang
- Key Laboratory of Exercise and Health Sciences of Ministry of Education, School of Kinesiology, Shanghai University of Sport, Shanghai, China.
| |
Collapse
|
3
|
Techniques for In Vivo Measurement of Ligament and Tendon Strain: A Review. Ann Biomed Eng 2020; 49:7-28. [PMID: 33025317 PMCID: PMC7773624 DOI: 10.1007/s10439-020-02635-5] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2020] [Accepted: 09/22/2020] [Indexed: 12/13/2022]
Abstract
The critical clinical and scientific insights achieved through knowledge of in vivo musculoskeletal soft tissue strains has motivated the development of relevant measurement techniques. This review provides a comprehensive summary of the key findings, limitations, and clinical impacts of these techniques to quantify musculoskeletal soft tissue strains during dynamic movements. Current technologies generally leverage three techniques to quantify in vivo strain patterns, including implantable strain sensors, virtual fibre elongation, and ultrasound. (1) Implantable strain sensors enable direct measurements of tissue strains with high accuracy and minimal artefact, but are highly invasive and current designs are not clinically viable. (2) The virtual fibre elongation method tracks the relative displacement of tissue attachments to measure strains in both deep and superficial tissues. However, the associated imaging techniques often require exposure to radiation, limit the activities that can be performed, and only quantify bone-to-bone tissue strains. (3) Ultrasound methods enable safe and non-invasive imaging of soft tissue deformation. However, ultrasound can only image superficial tissues, and measurements are confounded by out-of-plane tissue motion. Finally, all in vivo strain measurement methods are limited in their ability to establish the slack length of musculoskeletal soft tissue structures. Despite the many challenges and limitations of these measurement techniques, knowledge of in vivo soft tissue strain has led to improved clinical treatments for many musculoskeletal pathologies including anterior cruciate ligament reconstruction, Achilles tendon repair, and total knee replacement. This review provides a comprehensive understanding of these measurement techniques and identifies the key features of in vivo strain measurement that can facilitate innovative personalized sports medicine treatment.
Collapse
|
4
|
Englander ZA, Martin JT, Ganapathy PK, Garrett WE, DeFrate LE. Automatic registration of MRI-based joint models to high-speed biplanar radiographs for precise quantification of in vivo anterior cruciate ligament deformation during gait. J Biomech 2018; 81:36-44. [PMID: 30249338 PMCID: PMC6434938 DOI: 10.1016/j.jbiomech.2018.09.010] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2018] [Revised: 09/04/2018] [Accepted: 09/08/2018] [Indexed: 11/25/2022]
Abstract
Understanding in vivo joint mechanics during dynamic activity is crucial for revealing mechanisms of injury and disease development. To this end, laboratories have utilized computed tomography (CT) to create 3-dimensional (3D) models of bone, which are then registered to high-speed biplanar radiographic data captured during movement in order to measure in vivo joint kinematics. In the present study, we describe a system for measuring dynamic joint mechanics using 3D surface models of the joint created from magnetic resonance imaging (MRI) registered to high-speed biplanar radiographs using a novel automatic registration algorithm. The use of MRI allows for modeling of both bony and soft tissue structures. Specifically, the attachment site footprints of the anterior cruciate ligament (ACL) on the femur and tibia can be modeled, allowing for measurement of dynamic ACL deformation. In the present study, we demonstrate the precision of this system by tracking the motion of a cadaveric porcine knee joint. We then utilize this system to quantify in vivo ACL deformation during gait in four healthy volunteers.
Collapse
Affiliation(s)
- Zoë A Englander
- Department of Orthopaedic Surgery, Duke University, Durham, NC, USA; Department of Biomedical Engineering, Duke University, Durham, NC, USA
| | - John T Martin
- Department of Orthopaedic Surgery, Duke University, Durham, NC, USA
| | | | | | - Louis E DeFrate
- Department of Orthopaedic Surgery, Duke University, Durham, NC, USA; Department of Biomedical Engineering, Duke University, Durham, NC, USA; Department of Mechanical Engineering and Materials Science, Duke University, Durham, NC, USA.
| |
Collapse
|
5
|
Hart A, Sivakumaran T, Burman M, Powell T, Martineau PA. A Prospective Evaluation of Femoral Tunnel Placement for Anatomic Anterior Cruciate Ligament Reconstruction Using 3-Dimensional Magnetic Resonance Imaging. Am J Sports Med 2018; 46:192-199. [PMID: 28972789 DOI: 10.1177/0363546517730577] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND The recent emphasis on anatomic reconstruction of the anterior cruciate ligament (ACL) is well supported by clinical and biomechanical research. Unfortunately, the location of the native femoral footprint can be difficult to see at the time of surgery, and the accuracy of current techniques to perform anatomic reconstruction is unclear. PURPOSE To use 3-dimensional magnetic resonance imaging (3D MRI) to prospectively evaluate patients with torn ACLs before and after reconstruction and thereby assess the accuracy of graft position on the femoral condyle. STUDY DESIGN Cohort study; Level of evidence, 3. METHODS Forty-one patients with unilateral ACL tears were recruited into the study. Each patient underwent 3D MRI of both the injured and uninjured knees before surgery. The contralateral (uninjured) knee was used to define the patient's native footprint. Patients then underwent ACL reconstruction, and the injured knee underwent reimaging after surgery. The location and percentage overlap of the reconstructed femoral footprint were compared with the patient's native footprint. RESULTS The center of the native ACL femoral footprint was a mean 12.0 ± 2.6 mm distal and 9.3 ± 2.2 mm anterior to the apex of the deep cartilage. The position of the reconstructed graft was significantly different, with a mean distance of 10.8 ± 2.2 mm distal ( P = .02) and 8.0 ± 2.3 mm anterior ( P = .01). The mean distance between the center of the graft and the center of the native ACL femoral footprint (error distance) was 3.6 ± 2.6 mm. Comparing error distances among the 4 surgeons demonstrated no significant difference ( P = .10). On average, 67% of the graft overlapped within the native ACL femoral footprint. CONCLUSION Despite contemporary techniques and a concerted effort to perform anatomic ACL reconstruction by 4 experienced sports orthopaedic surgeons, the position of the femoral footprint was significantly different between the native and reconstructed ACLs. Furthermore, each surgeon used a different technique, but all had comparable errors in their tunnel placements.
Collapse
Affiliation(s)
- Adam Hart
- Department of Orthopedic Surgery, McGill University Health Centre, Montreal, Canada
| | - Thiru Sivakumaran
- Department of Diagnostic Radiology, McGill University Health Centre, Montreal, Canada
| | - Mark Burman
- Department of Orthopedic Surgery, McGill University Health Centre, Montreal, Canada
| | - Tom Powell
- Department of Diagnostic Radiology, McGill University Health Centre, Montreal, Canada
| | - Paul A Martineau
- Department of Orthopedic Surgery, McGill University Health Centre, Montreal, Canada
| |
Collapse
|