1
|
Yu W, Zou D, Tan J, Zheng N, Ma X, Cheng R, Chen Y, Tsai TY. Medial-pivot total knee arthroplasty enhances tibiofemoral axial rotation stability in weight-bearing mid-range flexion compared to posterior-stabilised system. Knee Surg Sports Traumatol Arthrosc 2024. [PMID: 38713882 DOI: 10.1002/ksa.12200] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/12/2024] [Revised: 04/03/2024] [Accepted: 04/07/2024] [Indexed: 05/09/2024]
Abstract
PURPOSE Total knee arthroplasty (TKA) stands as a primary intervention for severe knee ailments, yet concerns remain regarding postoperative patient satisfaction and flexion instability. This study aims to evaluate the in-vivo kinematics of medial-pivot (MP) and posterior-stabilised (PS) designs during step-up activity, in comparison to the kinematics of the nonoperated contralateral knee. METHODS Sixteen patients with PS-TKA and 14 with MP-TKA were retrospectively examined. Clinical outcomes were assessed using patient-completed questionnaires. Motion during step-up was captured using a dual fluoroscopic system. Statistical analysis was applied to evaluate the in-vivo tibiofemoral six-degree-of-freedom kinematics and articular contact positions between the two groups. RESULTS Despite being older, patients in the MP group reported higher postoperative subjective scores for weight-bearing functional activities. The axial rotation centres of MP-TKA located on the medial tibial plateau exhibited less variance compared to PS-TKA and contralateral knees. Compared to the contralateral knee (contralateral to medial-pivot [C-MP] or contralateral to posterior-stabilised [C-PS]), the MP group exhibited limited range of motion in terms of anteroposterior translation (MP: 3.6 ± 1.3 mm vs. C-MP: 7.4 ± 2.5 mm, p < 0.01) and axial rotation (MP: 6.6 ± 1.9° vs. C-MP: 10.3 ± 4.9°, p = 0.02), as well as in the PS group for anteroposterior translation (PS: 3.9 ± 1.7 mm vs. C-PS: 7.2 ± 3.7 mm, p < 0.01). CONCLUSION The MP group with better postoperative ratings demonstrated a more stable MP axial rotation pattern during step-up activity compared to the PS group, underscoring the pivotal role of prosthetic design in optimising postoperative rehabilitation and functional recovery. LEVEL OF EVIDENCE Level III.
Collapse
Affiliation(s)
- Wanxin Yu
- School of Biomedical Engineering & Med-X Research Institute, Shanghai Jiao Tong University, Shanghai, China
- Engineering Research Center of Digital Medicine and Clinical Translation, Ministry of Education, Shanghai, China
- Shanghai Key Laboratory of Orthopedic Implants & Clinical Translation R&D Center of 3D Printing Technology, Department of Orthopedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Diyang Zou
- School of Biomedical Engineering & Med-X Research Institute, Shanghai Jiao Tong University, Shanghai, China
- Engineering Research Center of Digital Medicine and Clinical Translation, Ministry of Education, Shanghai, China
- Shanghai Key Laboratory of Orthopedic Implants & Clinical Translation R&D Center of 3D Printing Technology, Department of Orthopedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Jiaqi Tan
- Department of Orthopedic Surgery, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Nan Zheng
- School of Biomedical Engineering & Med-X Research Institute, Shanghai Jiao Tong University, Shanghai, China
- Engineering Research Center of Digital Medicine and Clinical Translation, Ministry of Education, Shanghai, China
- Shanghai Key Laboratory of Orthopedic Implants & Clinical Translation R&D Center of 3D Printing Technology, Department of Orthopedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Xin Ma
- Department of Orthopedic Surgery, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Rongshan Cheng
- School of Biomedical Engineering & Med-X Research Institute, Shanghai Jiao Tong University, Shanghai, China
- Engineering Research Center of Digital Medicine and Clinical Translation, Ministry of Education, Shanghai, China
- Shanghai Key Laboratory of Orthopedic Implants & Clinical Translation R&D Center of 3D Printing Technology, Department of Orthopedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Yunsu Chen
- Department of Orthopedic Surgery, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Tsung-Yuan Tsai
- School of Biomedical Engineering & Med-X Research Institute, Shanghai Jiao Tong University, Shanghai, China
- Engineering Research Center of Digital Medicine and Clinical Translation, Ministry of Education, Shanghai, China
- Shanghai Key Laboratory of Orthopedic Implants & Clinical Translation R&D Center of 3D Printing Technology, Department of Orthopedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- Research and Development Division, TAOiMAGE Medical Technologies Corporation, Shanghai, China
| |
Collapse
|
2
|
Kawaguchi K, Yamagami R, Kenichi K, Kage T, Murakami R, Arakawa T, Inui H, Taketomi S, Tanaka S. Intraoperative reliability of the tibial anteroposterior axis "Akagi's Line" in total knee arthroplasty. J Exp Orthop 2024; 11:e12020. [PMID: 38617135 PMCID: PMC11009861 DOI: 10.1002/jeo2.12020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/28/2023] [Revised: 02/10/2024] [Accepted: 03/16/2024] [Indexed: 04/16/2024] Open
Abstract
Purpose The tibial anatomical anteroposterior (AP) axis "Akagi's line" was originally defined on computed tomography (CT) in total knee arthroplasty (TKA); however, its intraoperative reproducibility remains unknown. This study aimed to evaluate the intraoperative reproducibility of the Akagi's line and its effect on postoperative clinical outcomes. Methods This prospective study included 171 TKAs. The rotational angle of the intraoperative Akagi's line relative to the original Akagi's line (RAA) defined on CT was measured. The RAA was calculated based on the tibial component rotational angles relative to the intraoperative Akagi's line measured using the navigation system and CT. The effects of RAA on postoperative clinical outcomes and rotational alignments of components were also evaluated. Results The mean absolute RAA (standard deviation) value was 5.5° (3.9°). The range of RAA was 22° internal rotation to 16° external rotation. Intraoperative Akagi's line outliers (RAA > 10°) were observed in 14% of the knees (24 knees). In outlier analysis, the tibial component rotation angle was externally rotated 6.5° (5.6°) in the outlier group and externally rotated 3.7° (4.2°) in the nonoutlier group (≤10°), with a significant difference between the two groups. Additionally, the outlier group (RAA > 10°) showed lower postoperative clinical outcomes. Conclusion The original Akagi's line defined on CT showed insufficient reproducibility intraoperatively. The poor intraoperative detection of Akagi's line could be the reason for the tibial component rotational error and worse postoperative clinical outcomes. Level of Evidence Level IV, case series.
Collapse
Affiliation(s)
- Kohei Kawaguchi
- Department of OrthopaedicsTokyo University HospitalBunkyoTokyoJapan
- Present address:
Department of OrthopaedicsTokyo University Hospital7‐3‐1 HongoBunkyo111‐0033TokyoJapan
| | - Ryota Yamagami
- Department of OrthopaedicsTokyo University HospitalBunkyoTokyoJapan
| | - Kono Kenichi
- Department of OrthopaedicsTokyo University HospitalBunkyoTokyoJapan
| | - Tomofumi Kage
- Department of OrthopaedicsTokyo University HospitalBunkyoTokyoJapan
| | - Ryo Murakami
- Department of OrthopaedicsTokyo University HospitalBunkyoTokyoJapan
| | - Takahiro Arakawa
- Department of OrthopaedicsTokyo University HospitalBunkyoTokyoJapan
| | - Hiroshi Inui
- Department of OrthopaedicsTokyo University HospitalBunkyoTokyoJapan
| | - Shuji Taketomi
- Department of OrthopaedicsTokyo University HospitalBunkyoTokyoJapan
| | - Sakae Tanaka
- Department of OrthopaedicsTokyo University HospitalBunkyoTokyoJapan
| |
Collapse
|
3
|
Strahovnik A, Strahovnik I, Fokter SK. Coronal Knee Alignment and Tibial Rotation in Total Knee Arthroplasty: A Prospective Cohort Study of Patients with End-Stage Osteoarthritis. Bioengineering (Basel) 2024; 11:296. [PMID: 38534570 DOI: 10.3390/bioengineering11030296] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2024] [Revised: 03/17/2024] [Accepted: 03/18/2024] [Indexed: 03/28/2024] Open
Abstract
Several studies have found a relationship between the rotational anatomy of the distal femur and the overall coronal lower limb alignment in knees with osteoarthritis (OA). Less is known about the rotation of the proximal tibia, especially in the context of total knee arthroplasty (TKA), where one of the goals of the surgery is to achieve the appropriate component-to-component rotation. The aim of this study was to investigate the relationship between the coronal alignment of the lower extremity and the relative proximal tibial rotation. A prospective cohort study of patients with an end-stage OA scheduled for TKA was conducted. All patients underwent a computed tomography (CT) scan and a standing X-ray of both lower limbs. A relative femorotibial rotation was measured separately for mechanical and kinematic alignment. A statistically significant correlation was found between the tibial varus and the external tibial rotation (p < 0.001). Out of 14 knees with high tibial varus (>5°), 13 (93%) and 7 (50%) knees had >10° of femorotibial rotation for the mechanical and kinematic alignment landmarks, respectively. In order to keep the component-to-component rotation within the 10° margin, more internal rotation of the tibial component is required in knees with higher tibial varus.
Collapse
Affiliation(s)
- Andrej Strahovnik
- Valdoltra Orthopeadic Hospital, Jadranska Cesta 31, 6280 Ankaran, Slovenia
- Faculty of Medicine, University of Ljubljana, Kongresni trg 12, 1000 Ljubljana, Slovenia
| | - Igor Strahovnik
- Faculty of Medicine, University of Ljubljana, Kongresni trg 12, 1000 Ljubljana, Slovenia
| | - Samo Karel Fokter
- Faculty of Medicine, University of Ljubljana, Kongresni trg 12, 1000 Ljubljana, Slovenia
- Clinical Department of Orthopedic Surgery, University Medical Centre Maribor, Ljubljanska 5, 2000 Maribor, Slovenia
- Faculty of Medicine, University of Maribor, Slomškov trg 15, 2000 Maribor, Slovenia
| |
Collapse
|
4
|
Zhang Q, Li Z, Chen Z, Peng Y, Jin Z, Qin L. Prediction of knee biomechanics with different tibial component malrotations after total knee arthroplasty: conventional machine learning vs. deep learning. Front Bioeng Biotechnol 2024; 11:1255625. [PMID: 38260731 PMCID: PMC10800660 DOI: 10.3389/fbioe.2023.1255625] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2023] [Accepted: 12/21/2023] [Indexed: 01/24/2024] Open
Abstract
The precise alignment of tibiofemoral components in total knee arthroplasty is a crucial factor in enhancing the longevity and functionality of the knee. However, it is a substantial challenge to quickly predict the biomechanical response to malrotation of tibiofemoral components after total knee arthroplasty using musculoskeletal multibody dynamics models. The objective of the present study was to conduct a comparative analysis between a deep learning method and four conventional machine learning methods for predicting knee biomechanics with different tibial component malrotation during a walking gait after total knee arthroplasty. First, the knee contact forces and kinematics with different tibial component malrotation in the range of ±5° in the three directions of anterior/posterior slope, internal/external rotation, and varus/valgus rotation during a walking gait after total knee arthroplasty were calculated based on the developed musculoskeletal multibody dynamics model. Subsequently, deep learning and four conventional machine learning methods were developed using the above 343 sets of biomechanical data as the dataset. Finally, the results predicted by the deep learning method were compared to the results predicted by four conventional machine learning methods. The findings indicated that the deep learning method was more accurate than four conventional machine learning methods in predicting knee contact forces and kinematics with different tibial component malrotation during a walking gait after total knee arthroplasty. The deep learning method developed in this study enabled quickly determine the biomechanical response with different tibial component malrotation during a walking gait after total knee arthroplasty. The proposed method offered surgeons and surgical robots the ability to establish a calibration safety zone, which was essential for achieving precise alignment in both preoperative surgical planning and intraoperative robotic-assisted surgical navigation.
Collapse
Affiliation(s)
- Qida Zhang
- Musculoskeletal Research Laboratory, Department of Orthopaedics and Traumatology, The Chinese University of Hong Kong, Hong Kong, Hong Kong SAR, China
| | - Zhuhuan Li
- State Key Laboratory for Manufacturing System Engineering, School of Mechanical Engineering, Xi’an Jiaotong University, Xi’an, China
| | - Zhenxian Chen
- Key Laboratory of Road Construction Technology and Equipment (Ministry of Education), School of Mechanical Engineering, Chang’an University, Xi’an, China
| | - Yinghu Peng
- CAS Key Laboratory of Human-Machine Intelligence-Synergy Systems, Shenzhen Institutes of Advanced Technology Chinese Academy of Sciences, Shenzhen, China
| | - Zhongmin Jin
- Tribology Research Institute, School of Mechanical Engineering, Southwest Jiaotong University, Chengdu, China
- Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds, United Kingdom
| | - Ling Qin
- Musculoskeletal Research Laboratory, Department of Orthopaedics and Traumatology, The Chinese University of Hong Kong, Hong Kong, Hong Kong SAR, China
| |
Collapse
|
5
|
Toro G, Braile A, Conza G, De Cicco A, Abu Mukh A, Placella G, Salini V. Unicompartimental knee arthroplasty metallosis treated with uni-on-uni revision: A case report. World J Orthop 2023; 14:889-896. [PMID: 38173807 PMCID: PMC10758592 DOI: 10.5312/wjo.v14.i12.889] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/29/2023] [Revised: 10/15/2023] [Accepted: 11/09/2023] [Indexed: 12/15/2023] Open
Abstract
BACKGROUND Metallosis is the result of metallic wear debris in the soft tissues and is associated to both local and systemic inflammatory response. Metallosis has been reported after total hip and total knee arthroplasty (TKA), but rarely after a unicompartimental knee arthroplasty (UKA). In the context of UKA metallosis, surgeons often opt for revision using a TKA. However, in this paper, the authors successfully treated UKA revising the metal back only. CASE SUMMARY Prior to treat our patient we conducted a literature research through which we identified eleven cases of metallosis after UKA, ten (90.9%) were treated revising using though a TKA. Only one case was managed through a uni-on-uni revision, reporting high knee function. Our patient complained worsening pain and function after a snap occurred at 16 mo after UKA implantation. At 18 mo following surgical debridment and uni-on-uni revision surgery, our patient exhibited a relevant improvement in Oxford Knee Score and a reduction of metal ion levels in the blood. CONCLUSION Our study highlights that in case of metallosis after UKA, the treatment may be based on surgical debridement and just revising the mobilized components.
Collapse
Affiliation(s)
- Giuseppe Toro
- Department of Medical and Surgical Specialties and Dentistry, University of Campania “Luigi Vanvitelli”, Naples 80138, Italy
| | - Adriano Braile
- Department of Medical and Surgical Specialties and Dentistry, University of Campania “Luigi Vanvitelli”, Naples 80138, Italy
| | - Gianluca Conza
- Department of Medical and Surgical Specialties and Dentistry, University of Campania “Luigi Vanvitelli”, Naples 80138, Italy
| | - Annalisa De Cicco
- Department of Medical and Surgical Specialties and Dentistry, University of Campania “Luigi Vanvitelli”, Naples 80138, Italy
| | - Assala Abu Mukh
- Department of Orthopaedics and Traumatology, San Raffaele Hospital, Milan 20132, Italy
| | - Giacomo Placella
- Department of Orthopaedics and Traumatology, San Raffaele Hospital, Milan 20132, Italy
| | - Vincenzo Salini
- Department of Orthopaedics and Traumatology, San Raffaele Hospital, Milan 20132, Italy
| |
Collapse
|
6
|
Lee H, Yanagisawa M, Sumino T, Sano Y, Chang Y, Kan J, Fujimaki H, Ryu K, Nakanishi K. The anteroposterior distance between the posterior edge of the medial tibial condyle and the posterior edge of the fibular head in the lateral view can be a reference in determining the axis perpendicular to the tibial anteroposterior axis. Knee 2023; 45:18-26. [PMID: 37734169 DOI: 10.1016/j.knee.2023.08.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/02/2023] [Revised: 06/06/2023] [Accepted: 08/15/2023] [Indexed: 09/23/2023]
Abstract
BACKGROUND Obtaining an accurate tibial lateral view is important during high tibial osteotomy. This study investigated whether the posterior edge of the medial/lateral tibial condyle (PEMTC/PELTC) and the posterior edge of the fibular head (PEFH) in a lateral view could be a reference for determining the accurate tibial lateral view. METHODS A total of 75 lower limbs in 38 subjects were evaluated in this study. In order to target healthy knees, subjects undergoing primary total hip arthroplasty were selected. The MF/LF, comprising the anteroposterior distance between PEMTC/PELTC and PEFH, was measured on the lateral view of the tibial bone model based on the tibial anteroposterior (AP) axis (true lateral view: TLV). In addition, measurements were calculated in the model with a 10° external/internal rotation. Using these measurements, linear regression analysis was performed to predict the tibial rotation with MF/LF. RESULTS The mean MF/LF was 0.9/4.6 mm (P < 0.001). MF and LF increased with incremental tibial rotation. Regression formulas were derived from these results as follows: Tibial rotation = (1) -1.01 + 1.06 × MF (R2 = 0.87, P < 0.001), (2) -8.70 + 1.86 × LF (R2 = 0.51, P < 0.001). The mean tibial rotation angle when MF was 0 mm was -0.9°. CONCLUSIONS Based on formula (1) and actual measurements, the mean tibial rotation angle when MF is 0 mm is an internal rotation of about 1°. Therefore, a lateral view, in which PEMTC and PEFH are seen colinearly, can be the approximate TLV. The MF can be a suitable intraoperative reference in determining TLV.
Collapse
Affiliation(s)
- Hyunho Lee
- Department of Orthopaedic Surgery, Nihon University School of Medicine, Tokyo, Japan.
| | - Masahiko Yanagisawa
- Department of Orthopaedic Surgery, Nihon University School of Medicine, Tokyo, Japan
| | - Takanobu Sumino
- Department of Orthopaedic Surgery, Nihon University School of Medicine, Tokyo, Japan
| | - Yutaka Sano
- Department of Orthopaedic Surgery, Nihon University School of Medicine, Tokyo, Japan
| | - Yingshih Chang
- Department of Orthopaedic Surgery, Nihon University School of Medicine, Tokyo, Japan
| | - Junichiro Kan
- Department of Orthopaedic Surgery, Nihon University School of Medicine, Tokyo, Japan
| | - Hirohisa Fujimaki
- Department of Orthopaedic Surgery, Nihon University School of Medicine, Tokyo, Japan
| | - Keinosuke Ryu
- Department of Orthopaedic Surgery, Nihon University School of Medicine, Tokyo, Japan
| | - Kazuyoshi Nakanishi
- Department of Orthopaedic Surgery, Nihon University School of Medicine, Tokyo, Japan
| |
Collapse
|
7
|
Ueyama H, Minoda Y, Sugama R, Ohta Y, Takemura S, Nakamura H. Mobile-bearing prosthesis suppresses the postoperative rotational mismatch and improves patient-reported outcome measurements better than fixed-bearing prosthesis: rotational analysis by 3D measurement in total knee arthroplasty. Arch Orthop Trauma Surg 2023; 143:6781-6790. [PMID: 37418005 DOI: 10.1007/s00402-023-04971-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/22/2022] [Accepted: 06/26/2023] [Indexed: 07/08/2023]
Abstract
INTRODUCTION It is preferable to reduce postoperative excessive rotational mismatch between the femur and tibia that causes poor clinical results following total knee arthroplasty (TKA). The aim of this study is to compare postoperative rotational mismatches and clinical outcomes with mobile- and fixed-bearing prostheses. MATERIALS AND METHODS This study classified 190 TKAs into two groups equally by propensity score matching: mobile-bearing group (n = 95) and fixed-bearing group (n = 95). Computed tomography images of the whole leg were taken at 2 weeks postoperatively. The component alignments, rotational mismatches between the femur and tibia, and rotations among components were measured three-dimensionally. The knee range of motion, New Knee Society Score (KSS) subjective sores, and Forgotten Joint Score (FJS-12) were assessed at the final follow-up. RESULTS Rotational mismatch between the femur and tibia was significantly less in the mobile- (- 0.8° ± 7.3°) than in the fixed-bearing (3.3° ± 8.5°, p < 0.001) group. New KSS functional activity score was significantly poorer in patients with excessive rotational mismatch (61.3 ± 21.4) than in those without it (49.5 ± 20.6, p = 0.02). Comparing mobile-bearing prosthesis, the use of fixed-bearing prosthesis was a risk factor for postoperative excessive rotational mismatch (odds ratio: 2.32, p = 0.03). CONCLUSION When compared to a fixed-bearing prosthesis, TKA using a mobile-bearing prosthesis could suppress the postoperative rotational mismatch between the femur and tibia that causes poor subjective functional activity score. However, since this study was conducted for PS-TKA, the results might not be applicable to other models.
Collapse
Affiliation(s)
- Hideki Ueyama
- Orthopedic Surgery, Osaka Rosai Hospital, 1179-3 Nagasonecho, Kitaku, Sakai, Osaka, 591-8025, Japan.
- Department of Orthopedic Surgery, Osaka Metropolitan University Graduate School of Medicine, 1-4-3 Asahimachi, Abenoku, Osaka, 545-8585, Japan.
| | - Yukihide Minoda
- Department of Orthopedic Surgery, Osaka Metropolitan University Graduate School of Medicine, 1-4-3 Asahimachi, Abenoku, Osaka, 545-8585, Japan
| | - Ryo Sugama
- Department of Orthopedic Surgery, Osaka Metropolitan University Graduate School of Medicine, 1-4-3 Asahimachi, Abenoku, Osaka, 545-8585, Japan
| | - Yoichi Ohta
- Department of Orthopedic Surgery, Osaka Metropolitan University Graduate School of Medicine, 1-4-3 Asahimachi, Abenoku, Osaka, 545-8585, Japan
| | - Susumu Takemura
- Orthopedic Surgery, Osaka Rosai Hospital, 1179-3 Nagasonecho, Kitaku, Sakai, Osaka, 591-8025, Japan
| | - Hiroaki Nakamura
- Department of Orthopedic Surgery, Osaka Metropolitan University Graduate School of Medicine, 1-4-3 Asahimachi, Abenoku, Osaka, 545-8585, Japan
| |
Collapse
|
8
|
Tone S, Hasegawa M, Naito Y, Wakabayashi H, Sudo A. Association between pre- and postoperative rotational mismatches of the femorotibial components and bones in bi-cruciate retaining and posterior stabilized total knee arthroplasty. Sci Rep 2023; 13:14902. [PMID: 37689778 PMCID: PMC10492851 DOI: 10.1038/s41598-023-42243-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2023] [Accepted: 09/07/2023] [Indexed: 09/11/2023] Open
Abstract
To clarify the association between pre- and postoperative rotational mismatches of the femorotibial components and bones for total knee arthroplasty (TKA) with bi-cruciate retaining (BCR) design and with fixed bearing posterior stabilized (PS) design. This retrospective cohort study included 40 BCR TKAs and 50 PS TKAs. Pre- and postoperative rotational mismatches of the femorotibial components and bones were measured by three-dimensional assessment based on computed tomography imaging. The mean value and percentage within ± 5° of pre- and postoperative rotational mismatches were compared between BCR TKA and PS TKA. Correlations between pre- and postoperative rotational mismatches of the femorotibial components and bones were investigated in BCR TKA and PS TKA. There was no significant difference in mean preoperative rotational mismatch of femorotibial components and bones between BCR TKA and PS TKA. Mean postoperative rotational mismatch of femorotibial components and bones was significantly greater in BCR TKA than in PS TKA. Postoperative rotational mismatch of the femorotibial components was within ± 5° in 21 knees (52.5%) for BCR TKA and in 43 knees (86.0%) for PS TKA. The rate of postoperative rotational mismatch of the femorotibial components and bones within ± 5° was significantly lower for BCR TKA than for PS TKA. In BCR TKA, there was a positive correlation between pre- and postoperative rotational mismatches of the femorotibial components and of bones. We consider these results can be attributed to the retention of both cruciate ligaments, which may affect the reduction of rotational permittance of the components and bones.
Collapse
Affiliation(s)
- Shine Tone
- Department of Orthopaedic Surgery, Mie University, Graduate School of Medicine, 2-174 Edobashi, Tsu, Mie, 514-8507, Japan
| | - Masahiro Hasegawa
- Department of Orthopaedic Surgery, Mie University, Graduate School of Medicine, 2-174 Edobashi, Tsu, Mie, 514-8507, Japan.
| | - Yohei Naito
- Department of Orthopaedic Surgery, Mie University, Graduate School of Medicine, 2-174 Edobashi, Tsu, Mie, 514-8507, Japan
| | - Hiroki Wakabayashi
- Department of Orthopaedic Surgery, Mie University, Graduate School of Medicine, 2-174 Edobashi, Tsu, Mie, 514-8507, Japan
| | - Akihiro Sudo
- Department of Orthopaedic Surgery, Mie University, Graduate School of Medicine, 2-174 Edobashi, Tsu, Mie, 514-8507, Japan
| |
Collapse
|
9
|
Connolly P, Coombs S, Schwarzkopf R. Mechanical complications after total knee arthroplasty. Expert Rev Med Devices 2023; 20:1105-1117. [PMID: 37950354 DOI: 10.1080/17434440.2023.2282744] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2023] [Accepted: 11/08/2023] [Indexed: 11/12/2023]
Abstract
INTRODUCTION With the increasing demand for total knee arthroplasty (TKA) and the burden of revision TKA on the healthcare system, as well as the quality of life implications for patients, it is extremely important for surgeons to be able to anticipate and prevent TKA mechanical complications. Surgeons must be familiar with the different causes and mechanisms of TKA complications so that they can properly treat patients with failed TKAs and better avoid these complications. AREAS COVERED This review addresses TKA mechanical complications and provides context for the topic. A detailed review of surgical factors, implant factors, and patient factors that contribute to mechanical complications after TKA is provided. All of the literature cited in this review was gathered from the PubMed online database using different keywords based on the section of the manuscript. EXPERT OPINION As surgeons and engineers solve certain issues in TKA, new challenges will inevitably arise. We must continue to push forward and innovate from both a surgical technique and implant design perspective.
Collapse
Affiliation(s)
- Patrick Connolly
- Department of Orthopedic Surgery, NYU Langone Health, New York, NY, USA
| | - Stefan Coombs
- Department of Orthopedic Surgery, NYU Langone Health, New York, NY, USA
| | - Ran Schwarzkopf
- Department of Orthopedic Surgery, NYU Langone Health, New York, NY, USA
| |
Collapse
|
10
|
Griffin J, Davis ET, Parsons H, Gemperle Mannion E, Khatri C, Ellard DR, Blyth MJ, Clement ND, Deehan D, Flynn N, Fox J, Grant NJ, Haddad FS, Hutchinson CE, Mason J, Mohindru B, Scott CEH, Smith TO, Skinner JA, Toms AD, Rees S, Underwood M, Metcalfe A. Robotic Arthroplasty Clinical and cost Effectiveness Randomised controlled trial (RACER-knee): a study protocol. BMJ Open 2023; 13:e068255. [PMID: 37295832 PMCID: PMC10277111 DOI: 10.1136/bmjopen-2022-068255] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/12/2022] [Accepted: 05/24/2023] [Indexed: 06/12/2023] Open
Abstract
INTRODUCTION Robotic-assisted knee replacement systems have been introduced to healthcare services worldwide in an effort to improve clinical outcomes for people, although high-quality evidence that they are clinically, or cost-effective remains sparse. Robotic-arm systems may improve surgical accuracy and could contribute to reduced pain, improved function and lower overall cost of total knee replacement (TKR) surgery. However, TKR with conventional instruments may be just as effective and may be quicker and cheaper. There is a need for a robust evaluation of this technology, including cost-effectiveness analyses using both within-trial and modelling approaches. This trial will compare robotic-assisted against conventional TKR to provide high-quality evidence on whether robotic-assisted knee replacement is beneficial to patients and cost-effective for healthcare systems. METHODS AND ANALYSIS The Robotic Arthroplasty Clinical and cost Effectiveness Randomised controlled trial-Knee is a multicentre, participant-assessor blinded, randomised controlled trial to evaluate the clinical and cost-effectiveness of robotic-assisted TKR compared with TKR using conventional instruments. A total of 332 participants will be randomised (1:1) to provide 90% power for a 12-point difference in the primary outcome measure; the Forgotten Joint Score at 12 months postrandomisation. Allocation concealment will be achieved using computer-based randomisation performed on the day of surgery and methods for blinding will include sham incisions for marker clusters and blinded operation notes. The primary analysis will adhere to the intention-to-treat principle. Results will be reported in line with the Consolidated Standards of Reporting Trials statement. A parallel study will collect data on the learning effects associated with robotic-arm systems. ETHICS AND DISSEMINATION The trial has been approved by an ethics committee for patient participation (East Midlands-Nottingham 2 Research Ethics Committee, 29 July 2020. NRES number: 20/EM/0159). All results from the study will be disseminated using peer-reviewed publications, presentations at international conferences, lay summaries and social media as appropriate. TRIAL REGISTRATION NUMBER ISRCTN27624068.
Collapse
Affiliation(s)
- James Griffin
- Warwick Clinical Trials Unit, Warwick Medical School, University of Warwick, Coventry, UK
- University Hospitals Coventry and Warwickshire NHS Trust, Coventry, UK
| | - Edward T Davis
- Royal Orthopaedic Hospital NHS Foundation Trust, Birmingham, UK
| | - Helen Parsons
- Warwick Clinical Trials Unit, Warwick Medical School, University of Warwick, Coventry, UK
- University Hospitals Coventry and Warwickshire NHS Trust, Coventry, UK
| | - Elke Gemperle Mannion
- Warwick Clinical Trials Unit, Warwick Medical School, University of Warwick, Coventry, UK
| | - Chetan Khatri
- Warwick Clinical Trials Unit, Warwick Medical School, University of Warwick, Coventry, UK
- University Hospitals Coventry and Warwickshire NHS Trust, Coventry, UK
| | - David R Ellard
- Warwick Clinical Trials Unit, Warwick Medical School, University of Warwick, Coventry, UK
- University Hospitals Coventry and Warwickshire NHS Trust, Coventry, UK
| | - Mark J Blyth
- Orthopaedic Research Unit, Department of Trauma and Orthopaedics, Glasgow Royal Infirmary, Glasgow, UK
| | - Nicholas David Clement
- Orthopaedics and Trauma, Royal Infirmary of Edinburgh, Edinburgh, UK
- Department of Orthopaedics, University of Edinburgh Division of Clinical and Surgical Sciences, Edinburgh, UK
| | - David Deehan
- Newcastle Upon Tyne Hospitals NHS Trust, Newcastle Upon Tyne, UK
| | | | | | | | - Fares S Haddad
- University College London Hospitals NHS Foundation Trust, London, UK
| | - Charles E Hutchinson
- University Hospitals Coventry and Warwickshire NHS Trust, Coventry, UK
- Warwick Medical School, University of Warwick, Coventry, UK
| | - James Mason
- Warwick Clinical Trials Unit, Warwick Medical School, University of Warwick, Coventry, UK
| | - Bishal Mohindru
- Warwick Clinical Trials Unit, Warwick Medical School, University of Warwick, Coventry, UK
| | - Chloe E H Scott
- Department of Orthopaedics, Royal Infirmary of Edinburgh, Edinburgh, UK
- University of Edinburgh Division of Clinical and Surgical Sciences, Edinburgh, UK
| | - Toby O Smith
- Warwick Clinical Trials Unit, Warwick Medical School, University of Warwick, Coventry, UK
| | - John A Skinner
- Royal National Orthopaedic Hospital NHS Trust, Stanmore, UK
| | - Andrew D Toms
- Royal Devon and Exeter NHS Foundation Trust, Exeter, UK
| | - Sophie Rees
- Bristol Trials Centre, University of Bristol, Bristol, UK
| | - Martin Underwood
- Warwick Clinical Trials Unit, Warwick Medical School, University of Warwick, Coventry, UK
- University Hospitals Coventry and Warwickshire NHS Trust, Coventry, UK
| | - Andrew Metcalfe
- Warwick Clinical Trials Unit, Warwick Medical School, University of Warwick, Coventry, UK
- University Hospitals Coventry and Warwickshire NHS Trust, Coventry, UK
| |
Collapse
|
11
|
Zhang ZH, Qi YS, Wei BG, Bao HRC, Xu YS. Application strategy of finite element analysis in artificial knee arthroplasty. Front Bioeng Biotechnol 2023; 11:1127289. [PMID: 37265991 PMCID: PMC10230366 DOI: 10.3389/fbioe.2023.1127289] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Accepted: 03/27/2023] [Indexed: 06/03/2023] Open
Abstract
Artificial knee arthroplasty, as the most effective method for the treatment of end-stage joint diseases such as knee osteoarthritis and rheumatoid arthritis, is widely used in the field of joint surgery. At present, Finite element analysis (FEA) has been widely used in artificial knee replacement biomechanical research. This review presents the current hotspots for the application of FEA in the field of artificial knee replacement by reviewing the existing research literature and, by comparison, summarizes guidance and recommendations for artificial knee replacement surgery. We believe that lower contact stress can produce less wear and complications when components move against each other, in the process of total knee arthroplasty (TKA), mobile-bearing prostheses reduce the contact surface stress of the tibial-femoral joint compared with fixed-bearing prostheses, thus reducing the wear of the polyethylene insert. Compared with mechanical alignment, kinematic alignment reduces the maximum stress and maximum strain of the femoral component and polyethylene insert in TKA, and the lower stress reduces the wear of the joint contact surface and prolongs the life of the prosthesis. In the unicompartmental knee arthroplasty (UKA), the femoral and tibial components of mobile-bearing prostheses have better conformity, which can reduce the wear of the components, while local stress concentration caused by excessive overconformity of fixed-bearing prostheses should be avoided in UKA to prevent accelerated wear of the components, the mobile-bearing prosthesis maintained in the coronal position from 4° varus to 4° valgus and the fixed-bearing prosthesis implanted in the neutral position (0°) are recommended. In revision total knee arthroplasty (RTKA), the stem implant design should maintain the best balance between preserving bone and reducing stress around the prosthesis after implantation. Compared with cemented stems, cementless press-fit femoral stems show higher fretting, for tibial plateau bone defects, porous metal blocks are more effective in stress dispersion. Finally, compared with traditional mechanical research methods, FEA methods can yield relatively accurate simulations, which could compensate for the deficiencies of traditional mechanics in knee joint research. Thus, FEA has great potential for applications in the field of medicine.
Collapse
Affiliation(s)
- Zi-Heng Zhang
- Orthopedics Center, Inner Mongolia People’s Hospital, Hohhot, China
- Graduate School, Inner Mongolia Medical University, Hohhot, China
| | - Yan-Song Qi
- Orthopedics Center, Inner Mongolia People’s Hospital, Hohhot, China
| | - Bao-Gang Wei
- Orthopedics Center, Inner Mongolia People’s Hospital, Hohhot, China
| | - Hu-Ri-Cha Bao
- Orthopedics Center, Inner Mongolia People’s Hospital, Hohhot, China
| | - Yong-Sheng Xu
- Orthopedics Center, Inner Mongolia People’s Hospital, Hohhot, China
| |
Collapse
|
12
|
Zhang Q, Peng Y, Chen Z, Jin Z, Qin L. Conformity design can change the effect of tibial component malrotation on knee biomechanics after total knee arthroplasty. Clin Biomech (Bristol, Avon) 2023; 105:105985. [PMID: 37182435 DOI: 10.1016/j.clinbiomech.2023.105985] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/23/2023] [Revised: 05/01/2023] [Accepted: 05/08/2023] [Indexed: 05/16/2023]
Abstract
BACKGROUND Component alignment is essential to improve knee function and survival in total knee arthroplasty. However, it is still unclear whether the conformity design of tibiofemoral component can mitigate abnormal knee biomechanics caused by component malrotation. The purpose of this study was to investigate whether the sagittal/coronal conformity design of the tibial component could change the effect of the tibial component malrotation on knee biomechanics in total knee arthroplasty. METHODS A developed patient-specific musculoskeletal multi-body dynamics model of total knee arthroplasty was used to investigate the effects of the sagittal/coronal conformity of the tibial component on knee contact forces and kinematics caused by tibial component malrotation during the walking gait. FINDINGS Medial and lateral contact forces, internal-external rotation, and anterior-posterior translation were significantly affected by tibial component malrotation after total knee arthroplasty during the walking gait. The lower sagittal conformity of the tibial component can mitigate the abnormal internal-external rotation caused by tibial component malrotation in total knee arthroplasty, the higher coronal conformity of the tibial component can mitigate the abnormal medial-lateral translation caused by tibial component malrotation in total knee arthroplasty. INTERPRETATION This study highlights the importance of the tibiofemoral conformity designs on knee biomechanics caused by component malrotation in total knee arthroplasty. The optimization of the tibiofemoral conformity designs should be thoroughly considered in the design of new implants and in the planning of surgical procedures.
Collapse
Affiliation(s)
- Qida Zhang
- Musculoskeletal Research Laboratory, Department of Orthopaedics & Traumatology, The Chinese University of Hong Kong, Hong Kong SAR, China.
| | - Yinghu Peng
- CAS Key Laboratory of Human-Machine Intelligence-Synergy Systems, Shenzhen Institutes of Advanced Technology Chinese Academy of Sciences, Shenzhen, China
| | - Zhenxian Chen
- Key Laboratory of Road Construction Technology and Equipment (Ministry of Education), School of Mechanical Engineering, Chang'an University, Xi'an, China
| | - Zhongmin Jin
- Tribology Research Institute, School of Mechanical Engineering, Southwest Jiaotong University, Chengdu, China; Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds, UK
| | - Ling Qin
- Musculoskeletal Research Laboratory, Department of Orthopaedics & Traumatology, The Chinese University of Hong Kong, Hong Kong SAR, China
| |
Collapse
|
13
|
Elkins J, Jennings JM, Johnson RM, Brady AC, Parisi TJ, Dennis DA. Component Rotation in Well-Functioning, Gap-Balanced Total Knee Arthroplasty without Navigation. J Arthroplasty 2023; 38:S204-S208. [PMID: 36963529 DOI: 10.1016/j.arth.2023.03.033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Revised: 03/09/2023] [Accepted: 03/13/2023] [Indexed: 03/26/2023] Open
Abstract
INTRODUCTION Malalignment of total knee arthroplasty (TKA) components is a potential cause of clinical failure following TKA. Since the goal of a gap-balancing (GB) technique is equal flexion and extension gaps secondary to soft-tissue balancing, and not necessarily component alignment, variation in component placement may exist. Our purpose was (1) to evaluate precision of component alignment in well-functioning GB TKAs performed without the aid of navigation using computed tomographic (CT) evaluation and (2) to determine any relationship between femoral version and/or tibial torsion and TKA component positioning. METHODS There were 93 well-functioning TKAs performed with an extension gap first GB technique with a minimum 2-year follow-up evaluated using CT to assess component rotational alignment, as well as osseous femoral version and tibial torsion. Femoral and tibial rotational alignment was assessed by previously described methods. RESULTS The mean Knee Society Score was 185.7 ± 21.7. Mean range of motion was 128.5 ± 7.8°. Femoral postero-condylar axis (relative to the transepicondylar axis) values ranged from -8.3 to 4.1° with a mean of -0.78 ± 2.7° (internal rotation). Mean tibial rotation was 17.2 ± 7.9° internal rotation relative to the tibial tubercle. No correlation was found between native femoral version and femoral component rotational alignment (Pearson's correlation coefficient, r, 0.007). Weak correlation was found between native tibial torsion and tibial component alignment (r = 0.24). CONCLUSIONS Despite being only a secondary objective with the GB technique, most components evaluated were within the desired range of rotation. Alignment was not influenced by native osseous rotational geometry.
Collapse
Affiliation(s)
| | - Jason Michael Jennings
- Colorado Joint Replacement, Denver, CO, USA; Department of Mechanical and Materials Engineering, University of Denver, Denver, CO, USA
| | | | | | | | - Douglas A Dennis
- Colorado Joint Replacement, Denver, CO, USA; Department of Mechanical and Materials Engineering, University of Denver, Denver, CO, USA; Department of Orthopaedics, University of Colorado School of Medicine, Denver, CO, USA; Department of Biomedical Engineering, University of Tennessee, Knoxville, TN, USA.
| |
Collapse
|
14
|
Luan Y, Wang H, Zhang M, Li J, Zhang N, Liu B, Su J, Fang C, Cheng CK. Comparison of navigation systems for total knee arthroplasty: A systematic review and meta-analysis. Front Surg 2023; 10:1112147. [PMID: 36733891 PMCID: PMC9888247 DOI: 10.3389/fsurg.2023.1112147] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2022] [Accepted: 01/03/2023] [Indexed: 01/19/2023] Open
Abstract
Background Component alignment is a crucial factor affecting the clinical outcome of total knee arthroplasty (TKA). Accelerometer-based navigation (ABN) systems were developed to improve the accuracy of alignment during surgery. This study aimed to compare differences in component alignment, clinical outcomes, and surgical duration when using conventional instrumentation (CONI), ABN, and computer navigation (CN) systems. Methods A comprehensive literature search was carried out using the Web of Science, Embase, PubMed, and Cochrane databases. Articles that met the eligibility criteria were included in the study. Meta-analyses were performed using the Cochrane Collaboration Review Manager based on Cochrane Review Method. The variables used for the analyses were postoperative clinical outcome (PCO), surgical duration, and component alignment, including the hip-knee-ankle (HKA) angle, coronal femoral angle (CFA), coronal tibial angle (CTA), sagittal femoral angle (SFA), sagittal tibial angle (STA), and the outliers for the mentioned angles. The mean difference (MD) was calculated to determine the difference between the surgical techniques for continuous variables and the odds ratio (OR) was used for the dichotomous outcomes. Results The meta-analysis of the CONI and ABN system included 18 studies involving 2,070 TKA procedures, while the comparison of the ABN and CN systems included 5 studies involving 478 TKA procedures. The results showed that the ABN system provided more accurate component alignment for HKA, CFA, CTA, and SFA and produced fewer outliers for HKA, CFA, CTA, and STA. However, while the ABN system also required a significantly longer surgical time than the CONI approach, there was no statistical difference in PCO for the two systems. For the ABN and CN systems, there was no statistical difference in all variables except for the ABN system having a significantly shorter surgical duration. Conclusion There was no significant difference in the accuracy of component alignment between the ABN and CN systems, but the ABN approach had a shorter surgical duration and at lower cost. The ABN system also significantly improved the accuracy of component alignment when compared to the CONI approach, although the surgery was longer. However, there was no significant difference in PCO between the CONI, ABN, and CN systems.
Collapse
Affiliation(s)
- Yichao Luan
- Key Laboratory of Biomechanics and Mechanobiology, Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Huizhi Wang
- Engineering Research Center of Digital Medicine, Ministry of Education; School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Min Zhang
- Key Laboratory of Biomechanics and Mechanobiology, Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Junwei Li
- Key Laboratory of Biomechanics and Mechanobiology, Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Ningze Zhang
- Key Laboratory of Biomechanics and Mechanobiology, Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Bolun Liu
- Key Laboratory of Biomechanics and Mechanobiology, Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Jian Su
- Key Laboratory of Biomechanics and Mechanobiology, Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Chaohua Fang
- Engineering Research Center of Digital Medicine, Ministry of Education; School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China,Department of Joint Surgery, Ningbo No.6 Hospital, Ningbo, China,Correspondence: Chaohua Fang Cheng-Kung Cheng
| | - Cheng-Kung Cheng
- Key Laboratory of Biomechanics and Mechanobiology, Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China,Engineering Research Center of Digital Medicine, Ministry of Education; School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China,Correspondence: Chaohua Fang Cheng-Kung Cheng
| |
Collapse
|
15
|
Nedopil AJ, Zamora T, Delman C, Howell SM, Hull ML. Which Asymmetric Tibial Component Is Optimally Designed for Calipered Kinematically Aligned Total Knee Arthroplasty? J Knee Surg 2022; 35:1610-1618. [PMID: 33932950 DOI: 10.1055/s-0041-1728815] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Calipered kinematically aligned (KA) total knee arthroplasty (TKA) restores the patient's prearthritic joint lines and sets internal-external rotation of the tibial component parallel to the flexion-extension (FE) plane, which is not a mechanical alignment (MA) target. Two asymmetric tibial components designed for MA set the tibial component to either a femoral component (FC) target or a tibial tubercle (TT) target. The study determined the optimal asymmetric tibial component to use with KA as the one with smaller IE deviation from the MA target, greater coverage of tibial resection, and lower incidence of cortical overhang. The study included 40 patients treated with bilateral calipered KA TKA with different asymmetric tibial components in opposite knees. A best-fit of a kinematic tibial template to the tibial resection set the template's slot parallel to the knee's FE plane. Each asymmetric tibial component's anterior-posterior (AP) axis was set parallel to the slot. Computer tomography analysis determined the IE deviation (-internal/+ external) of each tibial component from its MA target, tibial resection coverage by the baseplate and insert, and incidence of cortical overhang. The patient-reported Forgotten Joint Score (FJS) and Oxford Knee Score (OKS) determined outcomes. The mean IE deviation from the MA target was 2 degrees external for the FC-target asymmetric tibial component and -8 degrees internal for the TT-target asymmetric tibial component (p < 0.001). Tibial resection coverage by the baseplate (insert) was 88% (84%) for the FC target and 84% (79%) for the TT target (p < 0.001 for baseplate and insert). The FC target insert covered 3 mm more of the posterolateral resection (p < 0.001). Posteromedial coverage was comparable. The incidence of cortical overhang was 2.5% for each baseplate. There was no difference in FJS and OKS. When performing calipered KA, the more optimal design was the asymmetric tibial component with the FC target because of the smaller deviation from its MA target and the greater coverage of the tibial resection by the baseplate and insert.
Collapse
Affiliation(s)
- Alexander J Nedopil
- Department of Orthopaedic Surgery, König-Ludwig-Haus, University of Würzburg, Würzburg, Germany
| | - Tomas Zamora
- Department of Orthopaedic Surgery, Pontificia Universidad Catolica de Chile, Santiago, Chile
| | - Connor Delman
- Department of Orthopaedics, University of California, Davis, Davis, California
| | - Stephen M Howell
- Biomedical Engineering Graduate Group, University of California, Davis, Davis, California
| | - Maury L Hull
- Department of Mechanical Engineering, University of California, Davis, Davis, California
| |
Collapse
|
16
|
Luan Y, Zhang M, Ran T, Wang H, Fang C, Nie M, Wang M, Cheng CK. Correlation between component alignment and short-term clinical outcomes after total knee arthroplasty. Front Surg 2022; 9:991476. [PMID: 36311927 PMCID: PMC9606652 DOI: 10.3389/fsurg.2022.991476] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2022] [Accepted: 09/26/2022] [Indexed: 12/05/2022] Open
Abstract
OBJECTIVE This study aimed to investigate the correlation between component alignment and short-term clinical outcomes after total knee arthroplasty (TKA). METHODS 50 TKA patients from a regional hospital were enrolled in the study. The following component alignments were measured from radiological data acquired within 1 week after surgery: hip-knee-ankle angle (HKA), medial distal femoral angle (MDFA), medial proximal tibial angle (MPTA), femoral flexion-extension angle (FEA), tibial slope angle (TSA), femoral rotational angle (FRA) and tibial rotational angle (TRA). The Hospital for Special Surgery (HSS) knee scoring system was used to assess clinical outcomes after 1 year, with patients being divided into three groups (excellent, good and not good) according to the HSS scores. Difference analysis and linear correlation analysis were used for the statistical analysis. RESULTS The results showed significant differences in MDFA (p = 0.050) and FEA (p = 0.001) among the three patient groups. It was also found that the total HSS had only a moderate correlation with FEA (r = 0.572, p < 0.001), but FEA had a positive linear correlation with pain scores (r = 0.347, p = 0.013), function scores (r = 0.535, p = 0.000), ROM scores (r = 0.368, p = 0.009), muscle scores (r = 0.354, p = 0.012) and stability scores (r = 0.312, p = 0.028). A larger MDFA was associated with lower FE deformity scores (r = -0.289, p = 0.042) and the TSA had a positive influence on the ROM (r = 0.436, p = 0.002). Also, changes in FRA produced a consequent change in the FE deformity score (r = 0.312, p = 0.027), and the muscle strength scores increased as TRA increased (r = 0.402, p = 0.004). CONCLUSION The results show that the FEA plays a significant role in clinical outcomes after TKA. Surgical techniques and tools may need to be improved to accurately adjust the FEA to improve joint functionality and patient satisfaction.
Collapse
Affiliation(s)
- Yichao Luan
- School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Min Zhang
- School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Tianfei Ran
- Department of Orthopaedics, Xinqiao Hospital, Army Military Medical University, Chongqing, China
| | - Huizhi Wang
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Chaohua Fang
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China,Department of Joint Surgery, Ningbo No.6 Hospital, Ningbo, China
| | - Maodan Nie
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Min Wang
- Department of Orthopaedics, Xinqiao Hospital, Army Military Medical University, Chongqing, China,Correspondence: Min Wang Cheng-Kung Cheng
| | - Cheng-Kung Cheng
- School of Biological Science and Medical Engineering, Beihang University, Beijing, China,School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China,Correspondence: Min Wang Cheng-Kung Cheng
| |
Collapse
|
17
|
Xin L, Xingjia M, Shengjie G, Yanwei C, Shuaijie L, Chuan X. Comparison of Tibial Tubercle Landmark Technique and Range of Motion Technique in Primary Total Knee Arthroplasty: A Retrospective Cohort Study. Orthop Surg 2022; 14:3159-3170. [PMID: 36238972 PMCID: PMC9732623 DOI: 10.1111/os.13486] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/10/2021] [Revised: 08/02/2022] [Accepted: 08/09/2022] [Indexed: 12/14/2022] Open
Abstract
OBJECTIVE There is not a standard for rotational alignment of the tibial component in total knee arthroplasty (TKA). For now, the most commonly methods are tibial-tubercle -landmark technique (TTL) and range-of-motion technique (ROM). The study is aimed to compare clinical outcomes and radiographic data of patients who undergone primary TKA with TTL or ROM technique. METHODS This single-surgeon retrospective cohort study includes 60 patients with TTL technique and 60 with ROM technique from December 2017 to January 2019. All patients were evaluated clinically using Hospital for Special Surgery Knee Score (HSS), Feller patellar score, visual analogue scale (VAS) and maximum knee flexion and extension angle before and after surgery at both 6 months and 12 months postoperatively. Radiographic data contain hip-knee-ankle angle (HKA), mechanical lateral distal femoral angle (mLDFA), mechanical medial proximal tibial angle (mMPTA), posterior slope angle (PSA) on pre and postoperative X-ray and rotation angle of femoral component (relative to surgical trans-epicondylar axis) and tibial component (relative to surgical trans-epicondylar axis, tibial posterior condylar line and Akagi') on postoperative computed tomography (CT) scan. Clinical outcomes and radiological data were compared between the two groups. RESULTS One hundred twenty patients (120 knees) were enrolled in this study, including 38 males and 82 females, aged from 58 to 78, with an average of 65.7 years. There was no significant difference in demographics and preoperative X-ray data between the two groups (P > 0. 05). Clinical scores of the TTL group were better than those in the ROM group at 6 and 12 months after surgery, when comparing HSS (83.57 ± 5.00 vs 75.90 ± 4.89, F = 59.004, P < 0.001; 90.53 ± 4.31 vs 82.83 ± 4.98, F = 54.509, P < 0.001), Feller patellar score (21.43 ± 2.54 vs 19.10 ± 2.52, F = 14.864, P = 0.001; 26.27 ± 1.98 vs 23.20 ± 2.31, F = 42.204, P < 0.001) and VAS (3.70 ± 0.62 vs 4.38 ± 0.92, F = 14.508, P = 0.001; 2.10 ± 0.90 vs 2.79 ± 0.80, F = 11.554, P = 0.002). But there was no significant difference in the flexion and extension angle between the two groups. In imaging evaluation, no statistical difference was found in pre- and postoperative HKA, mLDFA, mMPTA and PSA. Rotational angles of tibial component only did relative to Akagi' have statistical difference in two groups (2.33 ± 4.3 vs 4.41 ± 3.2, t = 2.143, P < 0.05) (Positive value represented external rotation). CONCLUSION The results of our study showed that both methods were reliable, and TTL technique provided better clinical scores and larger external angle of tibial component, compared to ROM technique.
Collapse
Affiliation(s)
- Liu Xin
- Department of Orthopaedic SurgeryThe Second Hospital of Shanxi Medical UniversityTaiyuanChina
| | - Mao Xingjia
- Department of Orthopaedic SurgeryThe Second Hospital of Shanxi Medical UniversityTaiyuanChina
| | - Guo Shengjie
- Department of Orthopaedic SurgeryThe Second Hospital of Shanxi Medical UniversityTaiyuanChina
| | - Cao Yanwei
- Department of Orthopaedic SurgeryThe Second Hospital of Shanxi Medical UniversityTaiyuanChina
| | - Li Shuaijie
- Department of Orthopaedic SurgeryThe Second Hospital of Shanxi Medical UniversityTaiyuanChina
| | - Xiang Chuan
- Department of Orthopaedic SurgeryThe Second Hospital of Shanxi Medical UniversityTaiyuanChina
| |
Collapse
|
18
|
Zhang LS, Zhou H, Zhang JC, Zhang Q, Chen XY, Feng S. Different tibial rotational axes can be applied in combination according to the tibial tuberosity-posterior cruciate ligament distance in total knee arthroplasty. BMC Musculoskelet Disord 2022; 23:906. [PMID: 36217137 PMCID: PMC9549616 DOI: 10.1186/s12891-022-05859-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/16/2022] [Accepted: 09/29/2022] [Indexed: 11/10/2022] Open
Abstract
Purpose The purpose of this study was to investigate whether tibial tuberosity–posterior cruciate ligament (TT-PCL) distance is representative of the true lateralization of tibial tuberosity in isolation and its influence on the accuracy of the Akagi line and medial third of the tibial tuberosity (MTTT). Methods A total of 135 osteoarthritis patients with varus knees who undergoing computed tomography scans were enrolled to establish three-dimension models of the knees. Tibial width (TW), tibial tuberosity lateralization (TTL), posterior cruciate ligament lateralization (PCLL), knee rotation angle (KRA) and tibial rotational axes were measured and investigated their correlations with TT-PCL distance. Based on the analysis of receiver operating characteristic (ROC) curve, the influence of TT-PCL distance on the distributions of mismatch angles of tibial rotational axes was investigated with a safe zone (-5° to 10°). Results TT-PCL distance was in significantly positive correlation with TW (r = 0.493; P < 0.001) and TTL (r = 0.378; P < 0.001) which was different with PCLL (r = 0.147; P = 0.009) and KRA (r = -0.166; P = 0.054). All tibial rotational axes were significantly positively correlated with TT-PCL distance (P < 0.001). The mismatch angles between the vertical line of the surgical epicondylar axis (SEA) and the Akagi line and MTTT were -1.7° ± 5.3° and 7.6° ± 5.6° respectively. In terms of the optimal cut-off value of 19 mm for TT-PCL distance, the Akagi line applied as tibial rotational axis ensures 87.3% of the positions of tibial components within the safe zone when TT-PCL distance > 19 mm, and MTTT ensures 83.3% when TT-PCL distance ≤ 19 mm. Conclusion TT-PCL distances cannot reflect the true lateralization of tibial tuberosity in isolation but can aid in the combination of the Akagi line and MTTT in varus knees. The patients with TT-PCL distance > 19 mm are recommended to reference the Akagi line for tibial rotational alignment. MTTT is recommended to the patients with TT-PCL distance ≤ 19 mm. The study will aid surgeons in deciding which reference may be used by measuring TT-PCL distance using a preoperative CT.
Collapse
Affiliation(s)
- Le-Shu Zhang
- Department of Orthopedic Surgery, Affiliated Hospital of Xuzhou Medical University, 99 Huaihai Road, Xuzhou, 221002, Jiangsu, China
| | - Hang Zhou
- Department of Orthopedic Surgery, Affiliated Hospital of Xuzhou Medical University, 99 Huaihai Road, Xuzhou, 221002, Jiangsu, China
| | - Jin-Cheng Zhang
- Department of Orthopedic Surgery, Affiliated Hospital of Xuzhou Medical University, 99 Huaihai Road, Xuzhou, 221002, Jiangsu, China
| | - Qiang Zhang
- Department of Orthopedic Surgery, Affiliated Hospital of Xuzhou Medical University, 99 Huaihai Road, Xuzhou, 221002, Jiangsu, China
| | - Xiang-Yang Chen
- Department of Orthopedic Surgery, Affiliated Hospital of Xuzhou Medical University, 99 Huaihai Road, Xuzhou, 221002, Jiangsu, China.
| | - Shuo Feng
- Department of Orthopedic Surgery, Affiliated Hospital of Xuzhou Medical University, 99 Huaihai Road, Xuzhou, 221002, Jiangsu, China.
| |
Collapse
|
19
|
Sotozawa M, Kumagai K, Yamada S, Nejima S, Inaba Y. Patient-specific instrumentation for total knee arthroplasty improves reproducibility in the planned rotational positioning of the tibial component. J Orthop Surg Res 2022; 17:403. [PMID: 36064582 PMCID: PMC9446751 DOI: 10.1186/s13018-022-03298-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Accepted: 08/22/2022] [Indexed: 11/17/2022] Open
Abstract
Background The purpose of this study was to evaluate the reproducibility of planned component positioning including tibial rotational alignment in patient-specific instrumentation (PSI) for total knee arthroplasty (TKA).
Methods A total of 100 knees of 100 patients underwent TKA using PSI (n = 50) or the conventional method (n = 50). Full-length anteroposterior radiographs of the lower limb were taken in the standing position, and the coronal alignments of the femoral and tibial components were measured. Computed tomography (CT) images of the lower limb were obtained preoperatively and postoperatively, and the rotational alignments of the femoral and tibial components were measured. The difference from the preoperative planning in tibial rotational alignment was measured using three-dimensionally merged pre- and postoperative images. The mean values and rates of outliers in each measurement were compared between the PSI group and the conventional group. Results There were no significant differences in coronal alignment of the femoral and tibial components and rotational alignment of the femoral component between the two groups. With respect to rotational alignment of the tibial component from the preoperatively planned reference axis, the PSI group showed a lower rate of outliers (internal rotation > 10°) than the conventional group (p < 0.05). Conclusions This study demonstrated that the difference from the preoperative planning in tibial rotational positioning was accurately evaluated using novel three-dimensional measurement method, and PSI could reduce outliers in rotational alignment of the tibial component (internal rotation > 10°). PSI is a useful technique for improving the reproducibility of the planned tibial rotational positioning in TKA.
Collapse
Affiliation(s)
- Masaichi Sotozawa
- Department of Orthopaedic Surgery, Graduate School of Medicine, Yokohama City University Hospital, Yokohama City University, 3-9 Fukuura, Kanazawa-ku, Yokohama, 236-0004, Japan
| | - Ken Kumagai
- Department of Orthopaedic Surgery, Graduate School of Medicine, Yokohama City University Hospital, Yokohama City University, 3-9 Fukuura, Kanazawa-ku, Yokohama, 236-0004, Japan.
| | - Shunsuke Yamada
- Department of Orthopaedic Surgery, Graduate School of Medicine, Yokohama City University Hospital, Yokohama City University, 3-9 Fukuura, Kanazawa-ku, Yokohama, 236-0004, Japan
| | - Shuntaro Nejima
- Department of Orthopaedic Surgery, Graduate School of Medicine, Yokohama City University Hospital, Yokohama City University, 3-9 Fukuura, Kanazawa-ku, Yokohama, 236-0004, Japan
| | - Yutaka Inaba
- Department of Orthopaedic Surgery, Graduate School of Medicine, Yokohama City University Hospital, Yokohama City University, 3-9 Fukuura, Kanazawa-ku, Yokohama, 236-0004, Japan
| |
Collapse
|
20
|
Different rotational alignment of tibial component should be selected for varied tibial tubercle locations in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 2022; 30:3061-3067. [PMID: 34669007 DOI: 10.1007/s00167-021-06774-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/11/2021] [Accepted: 10/08/2021] [Indexed: 10/20/2022]
Abstract
PURPOSE The main purpose of this study was to identify how the accuracy of the tibial rotation reference axes varied in populations with different tibial tubercle locations. We hypothesized that the accuracy of the axes of tibial rotation would be affected by the changes of tibial tubercle locations. METHODS Surgical epicondylar axis (SEA), medial third of the patellar tendon (1/3MPT), medial third of the tibial tuberosity (1/3MTT), medial border of the tibial tuberosity (MTT) and Akagi line were drawn. The angle between SEA and horizontal line with the angle between the four tibial rotation axes and the horizontal line was compared by T test. Then, the correlation between TTTG with the angles between the four axes and SEA vertical lines was analyzed. The TTTG was divided into three subgroups (TTTG < 10 mm, 10 mm ≤ TTTG < 15 mm, TTTG ≥ 15 mm), then t test was performed for the angles between the vertical lines of the SEA and the four rotation axes of the tibia in each group. RESULTS Among the four tibial rotation axes, only the difference between MTT and the line perpendicular to SEA had no statistical significance (NS.). The four tibial rotational axes were all positively correlated with TTTG (p < 0.001). When TTTG ≥ 15 mm, Akagi line was 2.5° ± 6.9°internally rotated to the line perpendicular to SEA, while the 1/3MPT and MTT was 0.9° ± 5.3°and 1.3° ± 5.9°externally rotated to the line perpendicular to the SEA when TTTG < 10 mm and 10 mm ≤ TTTG < 15 mm, respectively. CONCLUSIONS MTT showed the best consistency with SEA. TT-TG had a significant positive correlation with all four tibial rotational axes. In patients with TTTG < 10 mm, 10 mm ≤ TTTG < 15 mm and TTTG ≥ 15 mm, the 1/3MPT, MTT and Akagi line demonstrated good alignment consistency with SEA, respectively.
Collapse
|
21
|
Computer-assisted surgery and patient-specific instrumentation improve the accuracy of tibial baseplate rotation in total knee arthroplasty compared to conventional instrumentation: a systematic review and meta-analysis. Knee Surg Sports Traumatol Arthrosc 2022; 30:2654-2665. [PMID: 33646370 DOI: 10.1007/s00167-021-06495-x] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/26/2020] [Accepted: 02/05/2021] [Indexed: 02/08/2023]
Abstract
PURPOSE To determine whether patient-specific instrumentation (PSI), computer-assisted surgery (CAS) or robot-assisted surgery (RAS) enable more accurate rotational alignment of the tibial baseplate in primary total knee arthroplasty (TKA) compared to conventional instrumentation, in terms of deviation from the planned target and the proportion of outliers from the target zone. METHODS The authors independently conducted three structured electronic literature searches using the PubMed, Embase®, and Cochrane Central Register of Controlled Trials databases from 2007 to 2020. Studies were included if they compared rotational alignment of the tibial baseplate during TKA using conventional instrumentation versus PSI, CAS, and/or RAS, and reported deviation from preoperatively planned rotational alignment of the tibial baseplate in terms of absolute angles and/or number of outliers. Methodological quality of eligible studies was assessed by two researchers according to the Downs and Black Quality Checklist for Health Care Intervention Studies. RESULTS Fifteen studies, that reported on 2925 knees, were eligible for this systematic review, of which 6 studies used PSI, and 9 used CAS. No studies were found for RAS. Of the studies that reported on angular deviation from preoperatively planned rotational alignment, most found smaller deviations using PSI (0.5° to 1.4°) compared to conventional instrumentation (1.0° to 1.6°). All studies that reported on proportions of outliers from a target zone (± 3°), found lower rates of outliers using PSI (0 to 22%) compared to conventional instrumentation (5 to 96%). Most studies reported smaller angular deviation from preoperatively planned rotational alignment using CAS (0.1° to 6.9°) compared to conventional instrumentation (1.1° to 7.8°). Of the studies that reported on proportions of outliers from a target zone (± 3°), most found fewer outliers using CAS (10 to 61%) compared to conventional instrumentation (17 to 78%). CONCLUSION This systematic review and meta-analysis revealed that both CAS and PSI can improve the accuracy of rotational alignment of the tibial baseplate by decreasing angular deviation from the preoperatively planned target and reducing the proportion of outliers from the target zone. The clinical relevance is that PSI and CAS can improve alignment, though the thresholds necessary to grant better outcomes and survival remain unclear. LEVEL OF EVIDENCE IV.
Collapse
|
22
|
Mizu-Uchi H, Ma Y, Ishibashi S, Colwell CW, Nakashima Y, D'Lima DD. Tibial sagittal and rotational alignment reduce patellofemoral stresses in posterior stabilized total knee arthroplasty. Sci Rep 2022; 12:12319. [PMID: 35854017 PMCID: PMC9296446 DOI: 10.1038/s41598-022-15759-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2021] [Accepted: 06/29/2022] [Indexed: 11/09/2022] Open
Abstract
Patellofemoral joint complications remain an important issue in total knee arthroplasty. We compared the patellofemoral contact status between cruciate-retaining and posterior-stabilized designs with varying degrees of tibial sagittal and rotational alignment using a computer simulation to ensure proper alignments in total knee arthroplasty. Knee kinematics, patellofemoral contact force and quadriceps force were computed using a musculoskeletal modeling program (LifeMOD/KneeSIM 2010; LifeModeler, Inc., San Clemente, California) during a weight-bearing deep knee bend. Two different posterior tibial slope (PTS)s (3° and 7°) and five different tibial tray rotational alignments (neutral, internal 5° and 10°, and external 5° and 10°) were simulated. Patellofemoral contact area and stresses were next computed using finite element analysis. The patellofemoral contact force for the posterior-stabilized design was substantially lower than the cruciate-retaining design after post-cam contact because of increasing femoral roll-back. Neutral rotational alignment of the tibial component resulted in smaller differences in patellofemoral contact stresses between cruciate-retaining and posterior-stabilized designs for PTSs of 3° or 7°. However, the patellar contact stresses in the cruciate-retaining design were greater than those in posterior-stabilized design at 120° of knee flexion with PTS of 3° combined with internal rotation of the tibial component. Our study provides biomechanical evidence implicating lower PTSs combined with internal malrotation of the tibial component and the resultant increase in patellofemoral stresses as a potential source of anterior knee pain in cruciate-retaining design.
Collapse
Affiliation(s)
- Hideki Mizu-Uchi
- Department of Orthopaedic Surgery, Saiseikai Fukuoka General Hospital, 1-3-46, Tenjin, Chuo-ku, Fukuoka, 810-0001, Japan.,Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan
| | - Yuan Ma
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan
| | - Shojiro Ishibashi
- Department of Orthopaedic Surgery, Saiseikai Fukuoka General Hospital, 1-3-46, Tenjin, Chuo-ku, Fukuoka, 810-0001, Japan.,Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan
| | - Clifford W Colwell
- Shiley Center for Orthopaedic Research and Education at Scripps Clinic, 10666 North Torrey Pines Road, MS126, La Jolla, CA, 92037, USA
| | - Yasuharu Nakashima
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan
| | - Darryl D D'Lima
- Shiley Center for Orthopaedic Research and Education at Scripps Clinic, 10666 North Torrey Pines Road, MS126, La Jolla, CA, 92037, USA.
| |
Collapse
|
23
|
Fang C, Luan Y, Wang Z, Shao L, Qu T, Cheng CK. Moderate External Rotation of Tibial Component Generates More Natural Kinematics Than Internal Rotation After Total Knee Arthroplasty. Front Bioeng Biotechnol 2022; 10:910311. [PMID: 35910010 PMCID: PMC9327137 DOI: 10.3389/fbioe.2022.910311] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2022] [Accepted: 06/13/2022] [Indexed: 12/02/2022] Open
Abstract
This study aimed to investigate the influence of tibial malrotation on knee kinematics after total knee arthroplasty (TKA). A symmetric fixed-bearing posterior-stabilized prosthesis was implanted in the validated knee model with different rotational alignments of the tibial component (neutral, 3° external rotation, 5° external rotation, 3° internal rotation, and 5° internal rotation). Computational kinematic simulations were used to evaluate the postoperative kinematics of the knee joint including anteroposterior translation femoral condyles and axial rotation of tibial component during 0°–135° knee flexion. The results revealed that the neutral position of the tibial component was not the closest kinematics to the intact knee, the model with 5° external rotation of the tibial component showed the closest lateral condyle translation and tibial axial rotation, and moderate external rotation could improve the kinematics after TKA.
Collapse
Affiliation(s)
- Chaohua Fang
- Department of Joint Surgery, Ningbo No. 6 Hospital, Ningbo, China
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
- Engineering Research Center of Digital Medicine, Ministry of Education, Shanghai, China
| | - Yichao Luan
- School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Zhiwei Wang
- Department of Orthopaedics, Beijing Chaoyang Hospital, Beijing, China
| | - Long Shao
- Department of Joint Surgery, Ningbo No. 6 Hospital, Ningbo, China
| | - Tiebing Qu
- Department of Orthopaedics, Beijing Boai Hospital, Beijing, China
- The Center of Diagnosis and Treatment for Joint Disease, China Rehabilitation Research Center, Beijing, China
| | - Cheng-Kung Cheng
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
- Engineering Research Center of Digital Medicine, Ministry of Education, Shanghai, China
- *Correspondence: Cheng-Kung Cheng,
| |
Collapse
|
24
|
Eseonu O, Mactier M, Ferguson E, Quondamatteo F, Blyth M, Jones B. Soft-tissue landmarks for tibial baseplate rotational alignment in total knee arthroplasty: A cadaveric study. Clin Anat 2022; 35:1107-1113. [PMID: 35668648 DOI: 10.1002/ca.23921] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2021] [Revised: 05/31/2022] [Accepted: 06/04/2022] [Indexed: 11/11/2022]
Abstract
The tip of the tibial tubercle (TTT) is used to assess tibial baseplate rotation in total knee arthroplasty (TKA); however, it can be difficult to palpate and visualize intraoperatively. Several more easily accessible soft-tissue structures have been proposed as intraoperative assessments, including the patellar tendon's medial border (MBPT) and the junction of the medial third of the patellar tendon (mt-PT). No studies have described the relationship between the TTT and these proposed landmarks. The aims of the study were to (1) determine the relationship of the soft-tissue landmarks to the TTT and (2) identify any sex differences in these measures. Measurements of the position of these soft-tissue landmarks relative to the TTT were made on 56 cadaveric knees (28 female) by two observers at the level of the standard tibial cut (10 mm distal to the lateral tibial plateau). The results obtained were compared by sex and side. On average, 50.7% (SD 6.79, range 33.1%-63.1%) of the patellar tendon footprint was medial to the TTT. There were no significant differences between the sexes or left and right lower limbs. However, there was large variability in the position of all the soft-tissue landmarks relative to the TTT. The results indicate that, on average, the patellar tendon footprint is evenly spread around the TTT. However, there is a large variability in the anatomical relationship between the soft-tissue landmarks and the TTT. Caution is advised if relying on these structures intraoperatively.
Collapse
Affiliation(s)
- Onyedikachi Eseonu
- Department of Trauma and Orthopaedics, Glasgow Royal Infirmary, Glasgow, Scotland
| | - Mhairi Mactier
- Department of Trauma and Orthopaedics, Glasgow Royal Infirmary, Glasgow, Scotland
| | | | - Fabio Quondamatteo
- Department of Anatomy and Regenerative Medicine, RCSI, Dublin 2, Ireland
| | - Mark Blyth
- Department of Trauma and Orthopaedics, Glasgow Royal Infirmary, Glasgow, Scotland
| | - Bryn Jones
- Department of Trauma and Orthopaedics, Glasgow Royal Infirmary, Glasgow, Scotland
| |
Collapse
|
25
|
Zhang H, Cao C, Zhang H, Han S. Determining the rotational alignment of the tibial component referring to the tibial tubercle during total knee arthroplasty: the tibial tubercle-trochlear groove can be an aid. J Orthop Surg Res 2022; 17:253. [PMID: 35509006 PMCID: PMC9069815 DOI: 10.1186/s13018-022-03139-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/15/2021] [Accepted: 04/19/2022] [Indexed: 12/04/2022] Open
Abstract
Background There is no consensus on anatomic landmarks or reference axes with which to accurately align rotational position of tibial component. Using the tibial tubercle, commonly referring to the Akagi line and the Insall line, for anatomic reference was widely accepted. However, it is unknown about the predictors that may affect the reliability of using the tibial tubercle for aligning tibial component rotation. The aims of our study were (1) to investigate the reproducibility and accuracy of using the tibial tubercle for aligning tibial component rotation and (2) to determine predictors resulting in discrepancies of the tibial component rotation when referring to the tibial tubercle. Method A total of 160 patients with osteoarthritis were recruited before total knee arthroplasty. The angle α formed by the tibial anteroposterior (AP) axis and the Akagi line and the angle β formed by the tibial AP axis and the Insall line were measured to quantify the discrepancies of the Akagi line and the Insall line. Independent variables, including the tibial tubercle-to-trochlear groove distance (TT-TG), tibial tubercle to posterior cruciate ligament (TT-PCL), and knee rotation angle (KRA), hip–knee–ankle angle (HKA), medial proximal tibial angle (MPTA), and tibial bowing (TB), were measured. Pearson’s product moment correlation coefficients and multivariable linear regression analysis were calculated to assess relationships between independent variables and the two defined angles. Results All defined measurement were available for 140 patients. The Akagi line rotated internally with 1.03° ± 4.25° in regard to the tibial AP axis. The Insall line rotated externally in regard to the tibial AP axis with 7.93° ± 5.36°. Three variables, including TT-TG, TT-PCL, and KRA, tended to be positively correlated with the angle α and the angle β. In terms of a cutoff of TT-TG = 9 mm, 100% cases and 97% cases for using the Akagi line and Insall line, respectively, were located in the defined safe zone (− 5° to 10°). Conclusion The tibial tubercle (the Akagi line and Insall line) is found to be a useful and promising anatomic landmark for aligning the tibial component rotation. The TT-TG, with a cutoff value of 9 mm, is helpful to choose the Akagi line or Insall line, alternatively.
Collapse
Affiliation(s)
- He Zhang
- Handan Branch, Huabeiyiliao Jiankangjituan Fengfeng Zongyiyuan, Handan, 056000, Hebei, China
| | - Chengming Cao
- Handan Branch, Huabeiyiliao Jiankangjituan Fengfeng Zongyiyuan, Handan, 056000, Hebei, China
| | - Han Zhang
- Handan Branch, Huabeiyiliao Jiankangjituan Fengfeng Zongyiyuan, Handan, 056000, Hebei, China
| | - Shoujiang Han
- Department of Orthopaedic Surgery, Huabeiyiliao Jiankangjituan Fengfeng Zongyiyuan, Handan, 056000, Hebei, China.
| |
Collapse
|
26
|
Navigation and robotics improved alignment compared with PSI and conventional instrument, while clinical outcomes were similar in TKA: a network meta-analysis. Knee Surg Sports Traumatol Arthrosc 2022; 30:721-733. [PMID: 33492410 DOI: 10.1007/s00167-021-06436-8] [Citation(s) in RCA: 29] [Impact Index Per Article: 14.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/25/2020] [Accepted: 01/05/2021] [Indexed: 01/25/2023]
Abstract
PURPOSE To achieve the desired alignment more accurately and improve postoperative outcomes, new techniques such as computer navigation (Navigation), patient-specific instruments (PSI) and surgical robots (Robot) are applied in Total Knee Arthroplasty (TKA). This network meta-analysis aims to compare the radiological and clinical outcomes among the above-mentioned techniques and conventional instruments (CON). METHODS A PRISMA network meta-analysis was conducted and study protocol was published online at INPLASY (INPLASY202060018). Three databases (PubMed, EMBASE and Cochrane) were searched up to June 1, 2020. Randomised controlled trials (RCTs) comparing any two of the four techniques were included. A Bayesian network meta-analysis was performed focusing on radiological and clinical outcomes. The odds ratio (OR) or mean difference (MD) in various outcomes were calculated, and the interventions were ranked by the surface under the cumulative ranking area (SUCRA) value. RESULTS Seventy-three RCTs were included, with a total of 4209 TKAs. Navigation and Robot could significantly reduce the occurrence of malalignment and malposition compared with PSI and CON, and Navigation could obtain higher medium-and-long-term KSS knee scores than CON. Robot had the greatest advantage in achieving the desired alignment accurately, followed by Navigation; Navigation had the greatest advantage in the KSS score. CONCLUSION Navigation and Robot did improve the accuracy of alignment compared with PSI and conventional instrument in TKA, but the above four techniques showed no clinical significance in postoperative outcomes. LEVEL OF EVIDENCE I.
Collapse
|
27
|
Mell SP, Wimmer MA, Jacobs JJ, Lundberg HJ. Optimal surgical component alignment minimizes TKR wear - An in silico study with nine alignment parameters. J Mech Behav Biomed Mater 2022; 125:104939. [PMID: 34740015 PMCID: PMC8710043 DOI: 10.1016/j.jmbbm.2021.104939] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2021] [Revised: 10/18/2021] [Accepted: 10/25/2021] [Indexed: 01/03/2023]
Abstract
Currently, preclinical mechanical wear testing of total knee replacements (TKRs) is done using ideally aligned components using standardized TKR level walking under either force or displacement-control regimes. To understand the influence of implant alignment and testing control regime, we studied the effect of nine component alignment parameters on TKR volumetric wear in silico. We used a computational framework combining Latin Hypercube sampling design of experiments, finite element analysis, and a numerical model of polyethylene wear, to create a predictive model of how component alignment affects wear rate for each control regime. Nine component alignment parameters were investigated, five femoral variables and four tibial variables. To investigate perturbations of the nine implant alignment variables, two separate 300-point designs were executed, one for each control regime. The results were then used to generate surrogate statistical models using stepwise multiple linear regression. Wear at the neutral position was 4.5mm3/million cycle and 8.6mm3/million cycle for displacement and force-control, respectively. Stepwise multiple linear regression surrogate models were highly significant for each control regime, but force-control generated a stronger predictive model, with a higher R2, more included terms, and a lower RMSE. Both models predicted transverse plane rotational mismatch can lead to large changes in predicted wear; a transverse plane alignment mismatch of 15° can elicit a change in wear of up to 5mm3/million cycle, almost double that of neutral alignment. Therefore, transverse plane alignment is particularly important when considering failure of the implant due to wear.
Collapse
|
28
|
CT measures of femoral and tibial version and rotational position of femoral and tibial components of knee replacements: limitations in reliability and suitability for routine clinical practice. Eur Radiol 2022; 32:3790-3798. [PMID: 35142899 PMCID: PMC9122870 DOI: 10.1007/s00330-021-08483-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2021] [Revised: 10/31/2021] [Accepted: 11/25/2021] [Indexed: 11/26/2022]
Abstract
OBJECTIVES Rotational malalignment of knee replacements as measured on CT is understood to be associated with poor outcomes. The aim of this study is to measure the inter-rater and intra-rater reliability of measures of femoral and tibial version in the native arthritic knee and postoperative TKR component position using CT. METHODS Eighty patients underwent CT of the knee before and after total knee replacement. Preoperative femoral and tibial version and component rotation were independently measured by two musculoskeletal radiologists. RESULTS Mean differences between and within raters were small (< 1.6°). Maximum 95% limits of agreement for inter-rater and intra-rater comparisons were 8.1° and 7.6° for preoperative femoral version, 9.0° and 7.9° for postoperative femoral rotation, 26.0° and 20.5° for preoperative tibial version, and 24.9° and 23.6° for postoperative tibial rotation respectively. Postoperative ICCs varied from 0.68 to 0.81 (lower 95% CI:0.55-0.72) for both intra- and inter-rater comparisons. Preoperative ICCs were lower: 0.55-0.75 (lower 95% CI:0.40-0.65). CONCLUSION The lower 95% confidence level for ICC of version and rotational measurements using the Berger protocol of TKRs on CT are all less than 0.73 and that the normal range of differences between observers is up to 9° for the femoral component and 26° for the tibial component. This suggests that CT measurements derived from the Berger protocol may not be consistent enough for clinical practice. KEY POINTS • CT is commonly used to measure the rotational profile of knee replacements in symptomatic patients using the Berger protocol. • The limits of agreement for both femoral and tibial component rotation are wide even for experienced observers. • CT measurements of the rotation of knee arthroplasty are not reliable enough for routine clinical use.
Collapse
|
29
|
CT-based patient-specific instrumentation for total knee arthroplasty in over 700 cases: single-use instruments are as accurate as standard instruments. Knee Surg Sports Traumatol Arthrosc 2022; 30:447-455. [PMID: 32676744 PMCID: PMC8866287 DOI: 10.1007/s00167-020-06150-x] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/05/2020] [Accepted: 07/10/2020] [Indexed: 11/25/2022]
Abstract
PURPOSE Efforts in total knee arthroplasty are made to improve accuracy for a correct leg axis and reduce component malpositioning using patient-specific instruments. It was hypothesized that use of patient-specific instruments (vs. computer-navigated and conventional techniques) will reduce the number of outliers. Our second hypothesis was that single-use instrumentation will lead to the same accuracy compared to patient-specific instruments made of metal. METHODS 708 primary total knee arthroplasties between 2014 and 2018 using computer tomography (CT)-based patient-specific cutting block technique and a preoperative planning protocol were retrospectively reviewed. Preoperative data [hip-knee-angle (HKA), lateral distal femoral angle (LDFA), medial proximal tibial angle (MPTA), tibial slope, femoral component flexion] was compared to postoperative performed standard radiological follow-up X-rays. Differences of > 3° between measurements were defined as outliers. RESULTS Overall 500 prostheses using standard instrumentation and 208 prostheses using single-use instruments were implanted. Preoperative HKA axes (- 1.2°; p < 0.001), femoral component flexion (Δ 0.8°, p < 0.001), LDFA (Δ - 1.5°, p < 0.001), MPTA (Δ - 0.5°, p < 0.001) and tibial posterior slopes (Δ 0.5°, p < 0.001), respectively, were different from postoperative axes. More outliers occurred using standard (vs. single-use) instruments (p < 0.001) regarding postoperative HKA (ranges of standard- vs. single-use: instruments: HKA 178.0°-180.5° vs. 178.0°-180.5°, femoral component flexion 0.0°-6.0° vs. 0.0°-4.5°, LDFA 90.0°-91.0° vs. 90.0°-90.0°, MPTA 90.0°-90.0° vs. 90.0°-90.0°, tibial posterior slope - 10° to 10° vs. - 1° to 10°). No differences were seen for other angles measured. Comparing both systems, total number of outliers was higher using standard (8%) vs. single-use instruments (4.3%). CONCLUSION This study shows a high accuracy of CT-based patient-specific instrumentation concerning postoperative achieved knee angles and mechanical leg axes. Single-use instruments showed a similar accuracy. LEVEL OF EVIDENCE III.
Collapse
|
30
|
Accuracy of different navigation systems for femoral and tibial implantation in total knee arthroplasty: a randomised comparative study. Arch Orthop Trauma Surg 2021; 141:2267-2276. [PMID: 34652514 DOI: 10.1007/s00402-021-04205-3] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/03/2021] [Accepted: 09/29/2021] [Indexed: 10/20/2022]
Abstract
PURPOSE It remains to be established whether optical computed tomography (CT)-free and acceleration-based navigation systems differ in terms of implantation accuracy and clinical outcomes for total knee arthroplasty. This randomised prospective study compared the implantation accuracy of these two navigation systems in total knee arthroplasty. METHODS Optical CT-free navigation (ExactechGPS) or acceleration-based navigation (KneeAlign2) was randomly assigned to the left or right knee of 45 patients who underwent a single-stage bilateral total knee arthroplasty: the ExactechGPS (n = 45) and KneeAlign2 groups (n = 45) were compared. Component alignments were evaluated using three-dimensional computed tomography and radiography at pre- and post-surgery. Implantation accuracy of the component alignment, proportion of outliers, postoperative range of motion, and Japanese Orthopaedic Association (JOA) score were compared between the systems. RESULTS The implantation accuracies of the lower-extremity mechanical alignment, coronal femoral component angle, coronal tibial component angle, sagittal femoral component, axial femoral angle, and axial tibial angle had no significant difference between the groups. The implantation accuracy of the sagittal tibial component angle was superior in the ExactechGPS than the KneeAlign2 group (1.3° vs. 1.8°, P = 0.034). The proportions of outliers, range of motion, and JOA score had no significant difference between the groups. CONCLUSION In the tibial sagittal plane, there was a significant difference in the implantation accuracy, but its difference did not affect the clinical outcomes. Both navigation systems have clinically acceptable implantation accuracy.
Collapse
|
31
|
Maciąg BM, Stolarczyk A, Maciąg GJ, Dorocińska M, Stępiński P, Szymczak J, Świercz M, Żarnovsky K, Łapiński M, Stolarczyk M. Does the anatomic design of total knee prosthesis allow for a better component fit than its nonanatomic predecessor? A matched cohort Study. Arthroplast Today 2021; 12:62-67. [PMID: 34765714 PMCID: PMC8571411 DOI: 10.1016/j.artd.2021.09.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/12/2021] [Revised: 08/29/2021] [Accepted: 09/07/2021] [Indexed: 11/16/2022] Open
Abstract
Background Total knee arthroplasty (TKA) is considered the most efficient treatment of end-stage osteoarthritis. There is an ongoing debate about proper implant designs and articulation types. One of the considered causes of unsatisfactory outcome and patients’ dissatisfaction is femoral or tibial component overhanging, which can lead to chronic knee pain and restricted motion. The aim of this study is to compare radiological outcomes of TKA using an anatomic PERSONA Posterior-Stabilized (PS) knee design with its nonanatomic predecessor, the NexGen LPS. Methods A group of 39 patients who received the PERSONA PS system and 33 patients who received the NexGen LPS was included. PERSONA patients were matched to NexGen patients using a 0.1 propensity score threshold with priority given to exact matches. Anteroposterior, lateral, and long-leg radiographs were taken preoperatively and at 6 weeks postoperatively to perform radiological and statistical analysis. Results The PERSONA subgroup had statistically higher posterior condylar offset. There is no statistically significant difference in posterior condylar offset ratio. There were less cases of femoral notching, femoral overhang, and placing tibial baseplate in the medial overhang in the PERSONA PS subgroup than in the NexGen subgroup (each statistically significant). Occurrence of tibial underhang was not statistically significant. Conclusion Radiological assessment in short-term follow-up showed excellent results for PERSONA knee design with better fit to native femur and tibia. In comparison to its predecessor, it also spares more bone tissue. As the aforementioned parameters are risk factors of lesser clinical outcomes, the PERSONA design gives high hopes for improvement of TKA satisfaction rate.
Collapse
Affiliation(s)
- Bartosz M Maciąg
- Department of Orthopedics and Rehabilitation, Medical University of Warsaw, Warsaw, Poland
| | - Artur Stolarczyk
- Department of Orthopedics and Rehabilitation, Medical University of Warsaw, Warsaw, Poland
| | - Grzegorz J Maciąg
- Department of Orthopedics and Rehabilitation, Medical University of Warsaw, Warsaw, Poland
| | - Monika Dorocińska
- Department of Orthopedics and Rehabilitation, Medical University of Warsaw, Warsaw, Poland
| | - Piotr Stępiński
- Department of Orthopedics and Rehabilitation, Medical University of Warsaw, Warsaw, Poland
| | - Jakub Szymczak
- Department of Orthopedics and Rehabilitation, Medical University of Warsaw, Warsaw, Poland
| | - Maciej Świercz
- Department of Orthopedics and Rehabilitation, Medical University of Warsaw, Warsaw, Poland
| | - Krystian Żarnovsky
- Department of Orthopedics and Rehabilitation, Medical University of Warsaw, Warsaw, Poland
| | - Marcin Łapiński
- Department of Orthopedics and Rehabilitation, Medical University of Warsaw, Warsaw, Poland
| | - Magda Stolarczyk
- 3rd Clinic of Internal Medicine and Cardiology, Medical University of Warsaw, Warsaw, Poland
| |
Collapse
|
32
|
Nedopil AJ, Zamora T, Shelton T, Howell SM, Hull M. A Best-Fit of an Anatomic Tibial Baseplate Closely Parallels the Flexion-Extension Plane and Covers a High Percentage of the Proximal Tibia. J Knee Surg 2021; 34:1486-1494. [PMID: 32403149 DOI: 10.1055/s-0040-1710367] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
There are no reports of in vivo internal-external (I-E) rotational alignment and coverage of the proximal tibia after performing a best-fit method of an anatomically designed and asymmetrically shaped tibial baseplate during calipered kinematically aligned (KA) total knee arthroplasty (TKA). We hypothesized that a best-fit plane sets the anterior-posterior (A-P) axis of the anatomic baseplate closely parallel to the flexion-extension (F-E) plane of the knee and covers a high percentage of the proximal tibia. A total of 145 consecutive primary TKAs were prospectively collected. The calipered KA method and verification checks set the positions and orientations of the components without ligament release in all knees without restrictions on the preoperative deformities. A best-fit method selected one of six trials of anatomic baseplates that maximized coverage and set I-E rotation parallel to and within the cortical edge of the proximal tibia. The angle between the transverse axes of the components (i.e., the deviation of the A-P axis of the anatomic baseplate from the F-E plane of the native knee) and the cross-sectional area (CSA) of the proximal tibia were measured on postoperative computerized tomographic scans. The mean deviation of the anatomic baseplate from the F-E plane was 2-degree external ± 5 degrees. The mean coverage of the proximal tibia was 87 ± 6% (CSA of baseplate from the manufacturer/CSA of proximal tibia × 100). The anatomic baseplate and best-fit method adequately set I-E rotation of the baseplate closely parallel to the F-E plane of the knee and cover a high percentage of the proximal tibia.
Collapse
Affiliation(s)
- Alexander J Nedopil
- Department of Orthopaedic Surgery, University of Wuerzburg, Wuerzburg, Germany
| | - Tomas Zamora
- Department of Orthopaedic Surgery, Pontificia Universidad Catolica de Chile Facultad de Medicina, Santiago, Chile
| | - Trevor Shelton
- Department of Orthopedic Surgery, University of California, Davis, Sacramento, California
| | - Stephen M Howell
- Department of Biomedical Engineering, University of California, Davis, Sacramento, California
| | - Maury Hull
- Department of Orthopedic Surgery, University of California, Davis, Sacramento, California.,Department of Mechanical Engineering, University of California, Davis, California.,Department of Biomedical Engineering, University of California, Davis, California
| |
Collapse
|
33
|
Kazarian GS, Lieberman EG, Hansen EJ, Nunley RM, Barrack RL. Clinical impact of component placement in manually instrumented total knee arthroplasty : a systematic review. Bone Joint J 2021; 103-B:1449-1456. [PMID: 34465158 DOI: 10.1302/0301-620x.103b9.bjj-2020-1639.r2] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AIMS The goal of the current systematic review was to assess the impact of implant placement accuracy on outcomes following total knee arthroplasty (TKA). METHODS A systematic review was performed in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines using the Ovid Medline, Embase, Cochrane Central, and Web of Science databases in order to assess the impact of the patient-reported outcomes measures (PROMs) and implant placement accuracy on outcomes following TKA. Studies assessing the impact of implant alignment, rotation, size, overhang, or condylar offset were included. Study quality was assessed, evidence was graded (one-star: no evidence, two-star: limited evidence, three-star: moderate evidence, four-star: strong evidence), and recommendations were made based on the available evidence. RESULTS A total of 49 studies were identified for inclusion. With respect to PROMs, there was two-star evidence in support of mechanical axis alignment (MAA), femorotibial angle (FTA), femoral coronal angle (FCA), tibial coronal angle (TCA), femoral sagittal angle (FSA), femoral rotation, tibial and combined rotation/mismatch, and implant size/overhang or offset on PROMs, and one-star evidence in support of tibial sagittal angle (TSA), impacting PROMs. With respect to survival, there was three- to four-star evidence in support FTA, FCA, TCA, and TSA, moderate evidence in support of femoral rotation, tibial and combined rotation/mismatch, and limited evidence in support of MAA, FSA, and implant size/overhang or offset impacting survival. CONCLUSION Overall, there is limited evidence to suggest that PROMs are impacted by the accuracy of implant placement, and malalignment does not appear to be a significant driver of the observed high rates of patient dissatisfaction following TKA. However, FTA, FCA, TCA, TSA, and implant rotation demonstrate a moderate-strong relationship with implant survival. Efforts should be made to improve the accuracy of these parameters in order to improve TKA survival. Cite this article: Bone Joint J 2021;103-B(9):1449-1456.
Collapse
Affiliation(s)
- Gregory S Kazarian
- Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, New York, USA
| | - Elizabeth G Lieberman
- Department of Orthopaedic Surgery, Washington University School of Medicine, Barnes-Jewish Hospital, St Louis, Missouri, USA
| | - Erik J Hansen
- Department of Orthopaedic Surgery, Washington University School of Medicine, Barnes-Jewish Hospital, St Louis, Missouri, USA
| | - Ryan M Nunley
- Department of Orthopaedic Surgery, Washington University School of Medicine, Barnes-Jewish Hospital, St Louis, Missouri, USA
| | - Robert L Barrack
- Department of Orthopaedic Surgery, Washington University School of Medicine, Barnes-Jewish Hospital, St Louis, Missouri, USA
| |
Collapse
|
34
|
Toyoda S, Kaneko T, Igarashi T, Takada K, Yoshizawa S. Higher patellofemoral compressive force does not affect anterior knee pain in anatomical bi-cruciate retaining total knee arthroplasty: In vivo prospective analysis of guided motion prosthesis. Clin Biomech (Bristol, Avon) 2021; 88:105444. [PMID: 34364101 DOI: 10.1016/j.clinbiomech.2021.105444] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/16/2021] [Revised: 07/27/2021] [Accepted: 07/27/2021] [Indexed: 02/07/2023]
Abstract
BACKGROUND The purposes of the present study are 1) to measure intraoperative patellofemoral compressive force in patients undergoing anatomical bi-cruciate retaining total knee arthroplasty and to assess the relationship between intraoperative patellofemoral compressive force and patient reported outcome measurements and 2) to compare patellofemoral compressive force and patient reported outcome measurements among patients who underwent anatomical bi-cruciate retaining, cruciate retaining, and bi-cruciate stabilized total knee arthroplasty. METHODS Twenty-two patients with varus osteoarthritis of the knee who underwent anatomical bi-cruciate retaining total knee arthroplasty, 20 patients who underwent cruciate retaining total knee arthroplasty, and 24 patients who underwent bi-cruciate stabilized total knee arthroplasty were assessed. Patient reported outcome measurements were evaluated at 1.5 years after surgery. FINDINGS Intraoperative patellofemoral compressive force was significantly lower with anatomical bi-cruciate retaining total knee arthroplasty than with cruciate retaining total knee arthroplasty at 60° to 140° of flexion and nearly equivalent to intraoperative patellofemoral compressive force with bi-cruciate stabilized total knee arthroplasty at all knee flexion angles examined. With anatomical bi-cruciate retaining total knee arthroplasty, there were no significant correlations between intraoperative patellofemoral compressive force and almost all patient reported outcome measurements except for 2011 Knee Society Score expectations, which was positively correlated with patellofemoral compressive force at 10° of flexion, and Patella score quadriceps strength, which was negatively correlated with patellofemoral compressive force at 60° of flexion. INTERPRETATION There were no significant correlations between intraoperative patellofemoral compressive force and anterior knee pain after anatomical bi-cruciate retaining total knee arthroplasty. Evidence level: 3.
Collapse
Affiliation(s)
- Shinya Toyoda
- Ichinomiya Onsen Hospital, Adult Reconstruction Center, Japan
| | - Takao Kaneko
- Ichinomiya Onsen Hospital, Adult Reconstruction Center, Japan.
| | | | - Kazutaka Takada
- Ichinomiya Onsen Hospital, Adult Reconstruction Center, Japan
| | - Shu Yoshizawa
- Ichinomiya Onsen Hospital, Adult Reconstruction Center, Japan
| |
Collapse
|
35
|
Clinical and Radiological Outcomes after Knee Arthroplasty with Patient-Specific versus Off-the-Shelf Knee Implants: A Systematic Review. J Pers Med 2021; 11:jpm11070590. [PMID: 34206259 PMCID: PMC8304027 DOI: 10.3390/jpm11070590] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2021] [Revised: 06/15/2021] [Accepted: 06/18/2021] [Indexed: 12/27/2022] Open
Abstract
Customised, patient-specific implants (PSI) manufactured based on computed tomography data are intended to improve the clinical outcome by restoring more natural knee kinematics as well as providing a better fit and a more precise positioning. The aim of this systematic review is to investigate the effect of these PSI on the clinical and radiological outcome compared to standard, off-the-shelf (OTS) implants. Thirteen comparative studies including a total of 2127 knee implants were identified. No significant differences in clinical outcome assessed with the range of motion, the Knee Society Score (KSS), and the Forgotten Joint Score (FJS-12) were found between PSI and OTS implants. PSI showed fewer outliers from the neutral limb axis and a better implant fit and positioning. Whether these radiological differences lead to long-term advantages in terms of implant survival cannot be answered based on the current data. Patients receiving PSI could be discharged home earlier at the same or at an even lower total cost. The effective overall superiority of PSI has yet to be proven in long-term studies.
Collapse
|
36
|
Lee H, Sumino T, Suzuki T, Sano Y, Endo N, Chang Y, Fujimaki H, Ryu K, Nakanishi K. The medial tangent of the proximal tibia is a suitable extra-articular landmark in determining the tibial anteroposterior axis. BMC Musculoskelet Disord 2021; 22:346. [PMID: 33845795 PMCID: PMC8042940 DOI: 10.1186/s12891-021-04206-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/01/2021] [Accepted: 03/22/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Tibial rotational alignment in total knee arthroplasty (TKA) is generally determined based on intra-articular structure, and can be difficult to ascertain in some cases. The aim of this study was to investigate whether the medial tangent angle of the tibia (MTAT) could be useful in determining the anteroposterior axis of the tibia. METHODS This study was performed on 103 lower limbs in 53 patients who underwent primary total hip arthroplasty. The selection criteria for our study were based on the assumption that knees in patients undergoing THA exhibit fewer degenerative changes than knees in patients undergoing TKA. Using computed tomography images, the MTAT, comprising the medial tangent of the proximal tibia and the anteroposterior (AP) axis of the tibia, was measured on three horizontal planes: at the distal edge of the tibial tubercle (A), at 5 cm distally (B), and at 10 cm further distally (C). The tibial medial surface was grouped into three classes according to shape: valley type, flat type, and hill type. The percentage at which these shapes were observed in each group was also calculated. Measurement reliability was calculated using the intraclass correlation coefficient. RESULTS The angles were 45.2° (interquartile range: IR 43.0-47.7) at A, 42.7° (IR 38.7-45.9) at B, and 42.4° (IR 38.2-45.9) at C. Intra-rater reliability and inter-rater reliability was 0.982 and 0.974 at A, 0.810 and 0.411 at B, and 0.940 and 0.811 at C, respectively. Regarding the tibial medial surface, the valley type was observed in all cases at A, and the hill type was observed in the highest percentage of cases at B and C. CONCLUSIONS The MTAT was approximately 45° at level A, and reproducibility was the highest among the three groups. The two points forming the valley on the tibial medial surface were bony ridges. Therefore, the medial tangent of the tibia at level A could be easily determined. Because the distal edge of the tibial tubercle exists at the surgical area and the extra-articular area, it can be a suitable intraoperative, extra-articular landmark in determining the tibial AP axis, even for revision TKA.
Collapse
Affiliation(s)
- Hyunho Lee
- Department of Orthopaedic Surgery, Nihon University School of Medicine, 30-1 Oyaguchi Kami-cho, Itabashi-ku, Tokyo, 173-8610, Japan.
| | - Takanobu Sumino
- Department of Orthopaedic Surgery, Nihon University School of Medicine, 30-1 Oyaguchi Kami-cho, Itabashi-ku, Tokyo, 173-8610, Japan
| | - Takashi Suzuki
- Department of Orthopaedic Surgery, Eisei Hospital, 583-15 Kunugida, Hachioji-shi, Tokyo, 193-0942, Japan
| | - Yutaka Sano
- Department of Orthopaedic Surgery, Nihon University School of Medicine, 30-1 Oyaguchi Kami-cho, Itabashi-ku, Tokyo, 173-8610, Japan
| | - Noriyuki Endo
- Department of Orthopaedic Surgery, Nihon University School of Medicine, 30-1 Oyaguchi Kami-cho, Itabashi-ku, Tokyo, 173-8610, Japan
| | - Yingshih Chang
- Department of Orthopaedic Surgery, Nihon University School of Medicine, 30-1 Oyaguchi Kami-cho, Itabashi-ku, Tokyo, 173-8610, Japan
| | - Hirohisa Fujimaki
- Department of Orthopaedic Surgery, Nihon University School of Medicine, 30-1 Oyaguchi Kami-cho, Itabashi-ku, Tokyo, 173-8610, Japan
| | - Keinosuke Ryu
- Department of Orthopaedic Surgery, Nihon University School of Medicine, 30-1 Oyaguchi Kami-cho, Itabashi-ku, Tokyo, 173-8610, Japan
| | - Kazuyoshi Nakanishi
- Department of Orthopaedic Surgery, Nihon University School of Medicine, 30-1 Oyaguchi Kami-cho, Itabashi-ku, Tokyo, 173-8610, Japan
| |
Collapse
|
37
|
Increased external rotation of the osteoarthritic knee joint according to the genu varum deformity. Knee Surg Sports Traumatol Arthrosc 2021; 29:1098-1105. [PMID: 32556436 DOI: 10.1007/s00167-020-06100-7] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/04/2020] [Accepted: 06/11/2020] [Indexed: 10/24/2022]
Abstract
PURPOSE To evaluate the rotational profile of the lower extremity using computed tomography (CT) in accordance with the degree of varus deformity in medial condyle-affected knee joint osteoarthritis (OA). METHODS This retrospective study included 1036 patients (872 lower extremities) with end-stage knee OA. The coronal alignment of the lower extremity was measured using standing anteroposterior radiography. The CT parameters of femoral anteversion and tibial torsion were assessed in relation to the knee joint. The axes were the femoral neck axis; the distal femoral axis, which was composed of the anterior trochlear axis, the clinical transepicondylar axis, and the posterior condylar axis; the axis of the proximal tibial condyles; and the bimalleolar axis. RESULTS There was a tendency for increased external rotation of the knee joint parameters in relation to the hip and ankle joints as varus deformity of the lower extremity increased. The relative external rotational deformity of the knee joint in relation to the hip joint had a positive value with a good correlation. The relative external rotational deformity of the knee joint in relation to the ankle joint also demonstrated a positive value with a good correlation. CONCLUSION The distal femur and proximal tibia (knee joint) tended to rotate externally in relation to the hip and ankle joint, respectively, as the degree of varus deformity increased. This study identified the relationship between lower extremity varus deformity and rotational deformity of knee joints with OA. LEVEL OF EVIDENCE III.
Collapse
|
38
|
Kawaguchi K, Inui H, Yamagami R, Kenichi K, Sameshima S, Kage T, Taketomi S, Tanaka S. A new technique for determining the rotational alignment of the tibial component during total knee arthroplasty. Knee 2021; 29:323-331. [PMID: 33684863 DOI: 10.1016/j.knee.2021.02.006] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/18/2020] [Revised: 01/31/2021] [Accepted: 02/08/2021] [Indexed: 02/02/2023]
Abstract
BACKGROUND We evaluated the effectiveness of our new technique "Range of motion-anatomical (ROM-A) technique" which is the combination of the self-positioning technique "Range of motion (ROM) technique" and the anatomical landmarks technique in determining the tibial component (TC) rotation alignment in total knee arthroplasty (TKA) using a navigation system. METHODS This retrospective study included 103 knees who underwent TKA. The ROM-A technique was consisted of two steps. First, the TC was set and marked by the ROM technique in knee extension. Second, the TC was set according to the marking in the knee flexion and the component rotational angle relative to the anatomical tibial anteroposterior (AP) axis was adjusted between 0° and 10° external rotation using the navigation system. The rotational angle of TC relative to the anatomical AP axis was measured using postoperative computed tomography. Moreover, the hypothetical rotational angle of the TC in the ROM technique was calculated only from the intraoperative difference between the two techniques. RESULTS The actual rotational angle by the ROM-A technique was externally rotated 3.0°, and the rotational outlier occurred in 3.0%. A significant difference in outlier rate was observed between the two techniques (p = 0.03). The hypothetical rotational angle of TC determined by the ROM technique (the first step only in the ROM-A technique) was externally rotated 4.6° and the TC rotational outlier (difference to AP axis: >10°) occurred in 11.7%. CONCLUSION Using the ROM-A technique, the TC was finally fixed in almost all targeted rotational positions, and this technique could reduce the anatomical rotational outlier compared with the ROM technique.
Collapse
Affiliation(s)
- Kohei Kawaguchi
- Department of Orthopaedics, Tokyo University Hospital, Japan
| | - Hiroshi Inui
- Department of Orthopaedics, Tokyo University Hospital, Japan.
| | - Ryota Yamagami
- Department of Orthopaedics, Tokyo University Hospital, Japan
| | - Kono Kenichi
- Department of Orthopaedics, Tokyo University Hospital, Japan
| | - Shin Sameshima
- Department of Orthopaedics, Tokyo University Hospital, Japan
| | - Tomofumi Kage
- Department of Orthopaedics, Tokyo University Hospital, Japan
| | - Shuji Taketomi
- Department of Orthopaedics, Tokyo University Hospital, Japan
| | - Sakae Tanaka
- Department of Orthopaedics, Tokyo University Hospital, Japan
| |
Collapse
|
39
|
Kawaguchi K, Inui H, Taketomi S, Yamagami R, Kono K, Sameshima S, Kage T, Tanaka S. Preoperative tibiofemoral rotational alignment is a risk factor for component rotational mismatch in total knee arthroplasty. Knee 2021; 29:448-456. [PMID: 33743260 DOI: 10.1016/j.knee.2021.02.028] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/28/2020] [Revised: 01/13/2021] [Accepted: 02/22/2021] [Indexed: 02/02/2023]
Abstract
BACKGROUND Rotational mismatch between the femoral and tibial components is reported to be a risk factor for unsuccessful total knee arthroplasty (TKA). However, the rotational mismatch can still occur even when each component is aligned within the desired angle. Therefore, there may be other unknown factors. This study aims to investigate a risk factor for component rotational mismatch in TKA. The authors hypothesized a significant correlation between the rotational mismatch angle and not only the rotational alignments of components, but also the preoperative tibiofemoral rotation angle. METHOD This retrospective cohort study included 79 knees who underwent TKA. Computed tomography images were obtained preoperatively and 2 weeks after surgery for the component positional measurement. The postoperative component rotational mismatch angle between the tibial and femoral components and the rotational alignment of each tibial and femoral component to anatomical axes was evaluated. In addition, the preoperative rotational angle between the tibia and femur bones and patients' demographics were also investigated. The correlation between the postoperative component rotational mismatch angle and perioperative variables was analyzed to identify risk factors for component rotational mismatch. RESULTS The mean component rotational mismatch angle was 1.8° of internal rotation of the tibial component relative to the femoral component, and the angle ranged from 11.3° of internal rotation to 7.3° of external rotation of the tibial component. Multivariate regression analysis showed that the preoperative rotational alignment between the tibia and femur and the rotational alignment of each component were influential factors in the postoperative component rotational mismatch angle. CONCLUSION The preoperative tibiofemoral rotational alignment and the rotational alignment of each tibial and femoral component and are risk factors for the postoperative component rotational mismatch in TKA.
Collapse
Affiliation(s)
- Kohei Kawaguchi
- Department of Orthopaedics, Tokyo University Hospital, Japan
| | - Hiroshi Inui
- Department of Orthopaedics, Tokyo University Hospital, Japan.
| | - Shuji Taketomi
- Department of Orthopaedics, Tokyo University Hospital, Japan
| | - Ryota Yamagami
- Department of Orthopaedics, Tokyo University Hospital, Japan
| | - Kenichi Kono
- Department of Orthopaedics, Tokyo University Hospital, Japan
| | - Shin Sameshima
- Department of Orthopaedics, Tokyo University Hospital, Japan
| | - Tomofumi Kage
- Department of Orthopaedics, Tokyo University Hospital, Japan
| | - Sakae Tanaka
- Department of Orthopaedics, Tokyo University Hospital, Japan
| |
Collapse
|
40
|
Inui H, Taketomi S, Yamagami R, Kono K, Kawaguchi K, Uehara K, Tanaka S. Influence of surgical factors on patient satisfaction after bi-cruciate stabilized total knee arthroplasty: retrospective examination using multiple regression analysis. BMC Musculoskelet Disord 2021; 22:215. [PMID: 33622292 PMCID: PMC7903778 DOI: 10.1186/s12891-021-04098-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/26/2020] [Accepted: 02/17/2021] [Indexed: 12/28/2022] Open
Abstract
Background One of the causes of dissatisfaction following total knee arthroplasty (TKA) is abnormal knee kinematics. A newly designed bi-cruciate stabilized (BCS) TKA system has been developed to produce close-to-normal kinematics because of its anatomic tibiofemoral articular geometry and cam-post mechanism. Although BCS TKA is expected to improve patient satisfaction, no reports have described the appropriate technique or soft tissue handling required to achieve excellent satisfaction with BCS TKA. This study is to identify intraoperative surgical predictors of patient satisfaction after BCS TKA. Methods We studied 104 knees with primary varus knee osteoarthritis that underwent BCS TKA with a navigation system retrospectively. Surgical parameters including coronal, sagittal and axial alignment and joint laxity in each compartment that affected patient satisfaction was evaluated. Satisfaction score was evaluated with use of the 2011 Knee Society Scoring system. The multivariate regression analysis included age, gender, body mass index and intraoperative parameters that correlated with satisfaction scores in the univariate analysis (P < 0.05). The current study focused on the patient satisfaction score at 1 year postoperatively and didn’t evaluate the long term clinical results nor survivorship. Results The postoperative satisfaction score was 28.6 ± 8.1. Multivariate analysis showed that medial joint laxity at 30° flexion (P = 0.003), tibial excessive external rotation alignment (P = 0,009) and tibial varus alignment (P = 0.029) were predictors of poor satisfaction score. Conclusions When performing BCS TKA, surgeons should pay attention to maintaining proper stability of the medial compartment at mid flexion range and should avoid tibial varus and excessive external rotational alignment.
Collapse
Affiliation(s)
- Hiroshi Inui
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, 113-0033, Tokyo, Japan.
| | - Shuji Taketomi
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, 113-0033, Tokyo, Japan
| | - Ryota Yamagami
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, 113-0033, Tokyo, Japan
| | - Kenichi Kono
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, 113-0033, Tokyo, Japan
| | - Kohei Kawaguchi
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, 113-0033, Tokyo, Japan
| | - Kosuke Uehara
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, 113-0033, Tokyo, Japan
| | - Sakae Tanaka
- Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, 113-0033, Tokyo, Japan
| |
Collapse
|
41
|
Midflexion instability in total knee arthroplasty: a systematic review. Knee Surg Sports Traumatol Arthrosc 2021; 29:370-380. [PMID: 32133537 DOI: 10.1007/s00167-020-05909-6] [Citation(s) in RCA: 27] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/17/2019] [Accepted: 02/13/2020] [Indexed: 12/20/2022]
Abstract
PURPOSE The aim of this systematic review was to evaluate the evidence on the existence of midflexion instability in primary total knee arthroplasty and which factors might contribute to this condition. METHODS A comprehensive search of PubMed, Medline, Cochrane, CINAHL, and Embase databases was conducted since the inception of the database to July 2019. All relevant articles were retrieved, and their bibliographies were hand searched for further references on midflexion instability in primary total knee arthroplasty. The search strategy yielded 28 articles. After duplicate removal titles, abstracts and full text were reviewed. Fifteen studies were assessed for eligibility, 8 studies were excluded because they did not fully comply with the inclusion criteria. Seven articles were finally included in this systematic review. Anteroposterior translation, total knee arthroplasty design such as posterior-stabilized or posterior-cruciate-retaining total knee arthroplasty, joint line position with posterior condylar offset and joint gaps were considered to significantly influence midflexion stability. RESULTS Based on this systematic review anteroposterior translation of ≥ 7 mm was an independent risk factor for midflexion instability at 30° knee flexion. Joint line position can be altered by up to 5 mm without measurable changes in joint stability and both an increase and a decrease in posterior condylar offset led to 30° midflexion instability. CONCLUSION Midflexion instability in primary total knee arthroplasty remains to be not entirely understood. Due to the low quality of available evidence, it is difficult to make any definitive conclusions. The factors which can lead to this condition were analyzed in this review, furthermore, we did not find exhaustive evidence on midflexion instability existence as an isolated entity. Nonetheless, this review will form a baseline for future research and creates awareness for the routine assessment of midflexion instability in primary total knee arthroplasty. LEVEL OF EVIDENCE IV.
Collapse
|
42
|
Eseonu O, Cree C, Sambrook M, Blyth M, Jones B. The accuracy of femoral component rotational measurements using computed tomography—a cadaveric study. ARTHROPLASTY 2020; 2:36. [PMID: 35236456 PMCID: PMC8796577 DOI: 10.1186/s42836-020-00052-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2020] [Accepted: 10/12/2020] [Indexed: 11/30/2022] Open
Abstract
Background CT scans can be used to assess the rotational alignment of the femoral component following total knee arthroplasty (TKA). This is done by calculating the posterior condylar angle (PCA). However, the methods used may not account for the biomechanical functionality of the TKA components. This cadaveric study aimed to determine whether the axis of scanning (mechanical or anatomical) alters the results of PCA calculations. Methods CT scans of 12 cadaveric adult femora were performed along the anatomical axis and the mechanical axis. The PCA was determined on each CT scan by measuring the relationship of the prosthetic posterior condyles to the surgical epicondylar axis of the femur. The mechanical and anatomical axis groups were further subdivided into best-fit and multi-slice subgroups. As a control, the posterior condylar angle was also calculated on photographic images of each femur. Bland-Altman plots were used to determine the correlation between the PCA values obtained from the different scanning axes and measurement techniques. Results There was no significant difference between the PCA measurements derived from anatomical and mechanical axis CT scans. The Pearson correlation co-efficient also indicated good correlation between the two scanning axes. Conclusion The axis of scanning does not significantly affect the PCA measurements. Therefore, the measurements may be reliably used for clinical decision-making, regardless of the axis of CT scanning.
Collapse
|
43
|
Malrotation of the fixed-bearing posterior stabilized total knee prosthesis causes a postoperative rotational mismatch between the femur and tibia. Knee Surg Sports Traumatol Arthrosc 2020; 28:3810-3820. [PMID: 31996931 DOI: 10.1007/s00167-020-05864-2] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/15/2019] [Accepted: 01/17/2020] [Indexed: 02/06/2023]
Abstract
PURPOSE This study aimed to identify factors associated with rotational mismatch after total knee arthroplasty (TKA) using fixed-bearing posterior stabilized prosthesis and to evaluate the impact of the rotational mismatch on clinical outcomes. METHODS This retrospective cohort study included 159 cases that underwent TKA. Whole-leg computed tomography images were obtained 2 weeks after TKA, with three-dimensional measures of alignment. Rotational alignment of the femoral and tibial components and rotational mismatch between components and between the femur and tibia bones were evaluated. The new Knee Society Score (KSS) was obtained at the final outpatient visit, which was defined as the final follow-up timepoint. Predictive factors were identified for rotational mismatch of the lower extremity and poor new KSS. RESULTS The mean follow-up period was 42 ± 16 months. Rotational mismatch ≥ 10° between bones was identified in 56 cases (35%), with a mean mismatch angle of 5.0° ± 9.1° of external rotation of the tibia relative to the femur. Rotational mismatch ≥ 10° between components was identified in three cases (2%; mean 0.3° ± 3.6° of internal tibial rotation). A multivariate regression analysis showed that component malrotation was predictive of post-operative rotational mismatch between bones (p < 0.01) and rotational mismatch ≥ 10° associated with poor new KSS (odds ratio 4.22; p < 0.01). CONCLUSION Malrotation of the fixed-bearing posterior stabilized TKA causes a rotational mismatch between the femur and tibia bones. Excessive rotational mismatch between bones greater than 10° is a risk factor for poor postoperative functional outcome. Precise component positioning is essential for improving TKA outcomes. LEVEL OF EVIDENCE III.
Collapse
|
44
|
Ismailidis P, Kremo V, Mündermann A, Müller-Gerbl M, Nowakowski AM. Total knee arthroplasty: posterior tibial slope influences the size but not the rotational alignment of the tibial component. Knee Surg Sports Traumatol Arthrosc 2020; 28:3899-3905. [PMID: 32030500 DOI: 10.1007/s00167-020-05875-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/22/2019] [Accepted: 01/21/2020] [Indexed: 11/28/2022]
Abstract
PURPOSE The reasons leading to rotational tibial malalignment in total knee arthroplasties (TKAs) remain unclear. A previous cadaver study has shown an increase in internal rotation of the anatomical tibial axis (ATA) after the tibial cut. This study investigates the influence of tibial slope on the ATA and the size of the resected tibial surface. METHODS CT scans of 20 cadaver knees were orientated in a standardized coordinate system and used to determine the position of the centres of rotation of the medial and lateral tibial articular surfaces and, hence, of the ATA, after a virtual resection of 6 mm with 0°, 3.5°, 7° and 10° slope, respectively. Furthermore, at each slope, the radii of the medial and lateral tibial articular surfaces after resection were calculated. RESULTS Compared to resection of 6 mm with 0° slope, a slope of 3.5° resulted in a mean external rotation of the ATA of 0.9° (SD, 1.5°; P = 0.025). A slope of 7° resulted in a mean external rotation of the ATA of 1.0° (SD 2.0°; P = 0.030) and a slope of 10° had no influence on the rotation of the ATA. The radii of the medial and lateral articular surfaces of the cut tibiae were larger than those of the uncut tibia (P < 0.001). CONCLUSION Differences in the posterior tibial slope should not contribute to a rotational malalignment when using the ATA to align the prosthetic tibial plateau. Although statistically significant, the change in ATA with increasing slope was negligible.
Collapse
Affiliation(s)
- Petros Ismailidis
- Department of Orthopaedics and Traumatology, University Hospital of Basel, Spitalstrasse 21, 4031, Basel, Switzerland. .,Department of Clinical Research, University of Basel, Schanzenstrasse 55, 4056, Basel, Switzerland. .,Department of Biomedical Engineering, University of Basel, Gewerbestrasse 14, 4123, Allschwil, Switzerland.
| | - Valerie Kremo
- Department of Biomedicine, University of Basel, Pestalozzistrasse 20, 4056, Basel, Switzerland
| | - Annegret Mündermann
- Department of Orthopaedics and Traumatology, University Hospital of Basel, Spitalstrasse 21, 4031, Basel, Switzerland.,Department of Clinical Research, University of Basel, Schanzenstrasse 55, 4056, Basel, Switzerland.,Department of Biomedical Engineering, University of Basel, Gewerbestrasse 14, 4123, Allschwil, Switzerland
| | - Magdalena Müller-Gerbl
- Department of Biomedicine, University of Basel, Pestalozzistrasse 20, 4056, Basel, Switzerland
| | - Andrej Maria Nowakowski
- Department of Biomedicine, University of Basel, Pestalozzistrasse 20, 4056, Basel, Switzerland.,Department of Orthopaedics and Traumatology, Hospital of Uster, Brunnenstrasse 42, Postfach, 8610, Uster, Switzerland
| |
Collapse
|
45
|
Femoral component malrotation is not correlated with poor clinical outcomes after total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 2020; 28:3879-3887. [PMID: 32020253 DOI: 10.1007/s00167-020-05880-2] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/03/2019] [Accepted: 01/22/2020] [Indexed: 10/25/2022]
Abstract
PURPOSE Proper rotational alignment of the femoral component is critical for a successful total knee arthroplasty (TKA). The aim of this systematic review was to analyse the available literature to examine the effect of the TKA femoral component malrotation on clinical outcomes and assess a cut-off value for femoral rotation leading to revision surgery. METHODS A detailed and systematic search from 1996 to 2019 of the PUBMED, Medline, Cochrane Reviews and Google Scholar databases had been performed using the keyword terms "total knee arthroplasty OR replacement" AND "femoral alignment OR malalignment OR femoral rotation OR malrotation" AND "clinical outcome". We used the methodological index for non-randomized studies (MINORS) to identify scientifically sound articles in a reproducible format. RESULTS Eleven articles met inclusion criteria. A total of 896 arthroplasties were included in this review; 409 were unexplained painful TKA patients, while 487 were painless TKA patients. The mean age of patients was 67.5 (± 2.1) years. The mean post-operative follow-up delay was 46.8 (± 32.2) months. The mean of MINORS score was 21 points indicating good methodological quality in the included studies. CONCLUSIONS The present review confirms that the malrotation of the femoral component in TKA does not correlate automatically to poor clinical and functional outcome. The clinical relevance of this study was that, to improve accuracy in femoral component rotation, surgeons should consider the anatomical variability of femur in each knee and perform additional measurements pre- and intra-operatively. Taking a more accurate approach will shed light on unanswered questions in unhappy TKA. LEVEL OF EVIDENCE III.
Collapse
|
46
|
Klasan A, Twiggs JG, Fritsch BA, Miles BP, Heyse TJ, Solomon M, Parker DA. Correlation of tibial component size and rotation with outcomes after total knee arthroplasty. Arch Orthop Trauma Surg 2020; 140:1819-1824. [PMID: 32748043 DOI: 10.1007/s00402-020-03550-z] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/10/2020] [Accepted: 07/15/2020] [Indexed: 11/27/2022]
Abstract
INTRODUCTION Tibial component design and positioning contribute more to patient satisfaction than previously realized. A surgeon needs to decide on the size and rotation, bearing in mind that coverage should be as high as possible, whilst malrotation and overhang should be avoided. No study investigates the impact of each of these components on clinical outcomes in a single cohort. MATERIALS AND METHODS This is a retrospective analysis of 1-year postoperative outcomes measured with the Knee Injury and Osteoarthritis Outcome (KOOS) Score, as well as a previously validated rotational CT protocol. Coverage, rotation from Insall's axis, and overhang of an asymmetric tibial baseplate were measured, and positive and negative correlations to clinical outcomes were calculated. RESULTS A total of 499 knees were analyzed. Patient average age was 68.4 years. Rotation within 7° internal and 5° external from Insall's axis was a "safe zone". Mean coverage was 76%. A total of 429 knees (94%) had a coverage of at least 70% and 102 knees (22%) greater than 80%. Overhang was detected in 23% of the cohort. Increased coverage was correlated to increased KOOS score and overhang correlated with a decreased KOOS score (p = 0.008). CONCLUSIONS This study demonstrates the individual role of three aspects of tibial component implantation properties in postoperative pain and short-term functional outcomes. Upsizing to the point of overhang with rotational tolerance of 7° internal and 3° external to Insall's axis demonstrates best patient reported outcomes. Overhang decreases the clinical outcome by the same margin as loss of 16% of coverage.
Collapse
Affiliation(s)
- Antonio Klasan
- Sydney Orthopaedic Research Institute, Level 1, The Gallery, 445 Victoria Ave, Chatswood, NSW, 2067, Australia.
| | | | - Brett A Fritsch
- Sydney Orthopaedic Research Institute, Level 1, The Gallery, 445 Victoria Ave, Chatswood, NSW, 2067, Australia
| | | | | | | | - David A Parker
- Sydney Orthopaedic Research Institute, Level 1, The Gallery, 445 Victoria Ave, Chatswood, NSW, 2067, Australia
| |
Collapse
|
47
|
Internal rotation of the tibial component in total knee arthroplasty can lead to extension deficit. Knee Surg Sports Traumatol Arthrosc 2020; 28:2948-2952. [PMID: 31482183 DOI: 10.1007/s00167-019-05695-w] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/28/2018] [Accepted: 08/26/2019] [Indexed: 10/26/2022]
Abstract
PURPOSE Stiffness is a common problem following total knee arthroplasty (TKA). Mal-rotated components have been claimed to be the major cause of pain and limited motion after TKA. The present study investigates whether intra-operative intentional malrotation of the tibial component would change in vivo kinematics. The hypothesis is excessive internal rotation of the tibial component would result in postoperative extension deficit. METHODS Thirty-one patients were enrolled in this study. After completing bony cuts and proper soft tissue balancing, the femoral and tibial trials were impacted and fixed using small pins. Lateral radiographs were used to measure and compare intraoperative full knee extension during normal and after intentional internal rotation of the tibial component. The extension deficit angles were also compared between the posterior stabilised (PS) and cruciate retaining (CR) implants. RESULTS For normal tibial component rotation, the median (interquartile range) extension deficit was 0° (4). The mean tibial trial intentional internal rotation was 21.2° (± 4.5). The median (interquartile range) extension deficit significantly increased to 6° (4) after tibial component internal rotation (p = 0.001). The use of PS spacers resulted in a significantly greater extension deficit after intentional internal rotation 9° (5) compared to that of the CR implant 1° (4) (p = 0.001). CONCLUSION Internal rotation of the tibial component in total knee arthroplasty can lead to postoperative extension deficit. This could be attributed to interference with "screw home" mechanism that requires full external rotation of the tibia on the femur. Consequently, this deficit may cause pain and knee stiffness following TKA. LEVEL OF EVIDENCE III.
Collapse
|
48
|
Lu Y, Ren X, Liu B, Xu P, Hao Y. Tibiofemoral rotation alignment in the normal knee joints among Chinese adults: a CT analysis. BMC Musculoskelet Disord 2020; 21:323. [PMID: 32446307 PMCID: PMC7245925 DOI: 10.1186/s12891-020-03300-7] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/02/2020] [Accepted: 04/17/2020] [Indexed: 11/24/2022] Open
Abstract
Background Consensus on tibial rotation in total knee arthroplasty (TKA) remains controversial. The present study aimed to investigate the closest anatomical reference to surgical epicondylar axis (SEA) among 10 tibial markers in Chinese adults. Methods This study included examination of 122 normal lower extremities. Briefly, 10 axes were drawn on the axial sections: transverse axis of tibia (TAT), axis of medial edge of patellar tendon (MEPT), axis of medial 1/3 of patellar tendon attachment (M1/3), Akagi line, Insall line, axis of medial border of tibial tubercle (MBTT), and axis of anterior border of the tibia 1–4 (ATC1–4). The mean angles between TAT and SEA and that between other axes and the line perpendicular to SEA were measured. Pairwise differences among the 10 tibial axes were examined by applying one-way analysis of variance (ANOVA) and paired t-test. Results In all the knees, the mean angles of M1/3, Akagi line, Insall line, MBTT, ATC1, ATC2, ATC3, and ATC4 axes were compared to the line perpendicular to the projected SEA and found to be 10.2 ± 5.1°, 1.4 ± 5.0°, 11.9 ± 5.4°, 3.6 ± 4.8°, 12.0 ± 6.9°, 7.2 ± 8.6°, 7.1 ± 10.4°, and 6.6 ± 13.5° external rotation, respectively, and the MEPT axis was 1.6 ± 4.5° internal rotation. The mean angle for TAT was 4.1 ± 5.3° external rotation. The M1/3 and Insall line were significantly more externally rotated than Akagi line, MEPT, MBTT, TAT, ATC2, ATC3, and ATC4 axes. No significant differences were noted between the TAT axis and the MBTT axis and among the ATC2, ATC3, and ATC4 axes. Conclusion The Akagi line, MBTT, and TAT showed good consistency with SEA in the axial femorotibial alignment with knee in extension. The middle segment of the anterior tibial crest also demonstrated good alignment consistency with SEA for the axial femorotibial alignment. Hence, these markers can be used as reliable references for rotational alignment of the tibial component in TKA.
Collapse
Affiliation(s)
- Yufeng Lu
- Osteonecrosis and Joint Reconstruction Ward, Department of Joint Surgery, Honghui Hospital, Xi'an Jiaotong University, Xi'an, Shaanxi, 710054, P.R. China
| | - Xiaoyu Ren
- Osteonecrosis and Joint Reconstruction Ward, Department of Joint Surgery, Honghui Hospital, Xi'an Jiaotong University, Xi'an, Shaanxi, 710054, P.R. China
| | - Benyin Liu
- Department of Radiology and Imaging Sciences, Honghui Hospital, Xi'an Jiaotong University, Xi'an, Shaanxi, 710054, P.R. China
| | - Peng Xu
- Osteonecrosis and Joint Reconstruction Ward, Department of Joint Surgery, Honghui Hospital, Xi'an Jiaotong University, Xi'an, Shaanxi, 710054, P.R. China
| | - Yangquan Hao
- Osteonecrosis and Joint Reconstruction Ward, Department of Joint Surgery, Honghui Hospital, Xi'an Jiaotong University, Xi'an, Shaanxi, 710054, P.R. China.
| |
Collapse
|
49
|
Murer AM, Hirschmann MT, Amsler F, Rasch H, Huegli RW. Bone SPECT/CT has excellent sensitivity and specificity for diagnosis of loosening and patellofemoral problems after total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 2020; 28:1029-1035. [PMID: 31263926 DOI: 10.1007/s00167-019-05609-w] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/29/2019] [Accepted: 06/26/2019] [Indexed: 12/31/2022]
Abstract
PURPOSE The primary purpose of this retrospective study with prospectively collected data was to evaluate the clinical value of SPECT/CT, in particular its impact on clinical diagnosis and patient management, in patients with pain, stiffness, or swelling after primary total knee arthroplasty (TKA). The secondary purpose was to determine the sensitivity and the specificity of SPECT/CT for different pathologies such as loosening and patellofemoral overloading. METHODS A retrospective analysis was carried out on 214 knees in 202 consecutive patients (mean age 69 ± 11 years) with persistent or recurrent knee pain after TKA. All patients underwent clinical examination, standardised radiographs, and 99mTc-hydroxymethane diphosphonate (HDP) SPECT/CT as part of a routine diagnostic algorithm. The diagnoses before and after SPECT/CT and final treatment were recorded. TKA component position was routinely measured on 3D-reconstructed images. Intensity and anatomical distribution of bone tracer uptake were determined. RESULTS SPECT/CT changed the clinical diagnosis and final treatment in 139/214 (65%) knees. In 117 (54.7%) out of 214 patients, revision surgery was proposed following SPECT/CT. Early onset of pain was significantly (p = 0.011) correlated with tibiofemoral stress pattern in SPECT/CT. A total of 86 knees (40.2%) were surgically revised using semi-constrained or fully constrained TKA. In 35 patients, a secondary patellar resurfacing was performed. SPECT/CT showed the clinical diagnosis to be incorrect for suspicion of tibial component loosening in 56 patients (26.2%), femoral component loosening in 53 patients (24.8%), and patellofemoral overloading/progressive patellofemoral osteoarthritis in 26 patients (12.1%) and provided different underlying causes of persistent knee pain after TKA. Likewise, SPECT/CT identified tibial component loosening in 8 patients (3.7%), femoral component loosening in 4 patients (1.9%), and patellofemoral OA in 71 patients (33.2%) without prior clinical suspected diagnosis. The sensitivity and specificity of SPECT/CT for detection of patellofemoral OA was 96.5% and 96.2%, respectively. The sensitivity and specificity for detection of tibial component loosening was 96.0% and 100%, respectively. The sensitivity and specificity for detection of femoral component loosening was 95.0% and 100%, respectively. CONCLUSION The diagnostic benefits of SPECT/CT in the challenging and complex cohort of patients with pain after primary TKA have been proven. The excellent sensitivity and specificity for detection of tibial or femoral component loosening and diagnosis of patellofemoral OA have been surgically confirmed. Due to the benefits in establishing the correct diagnosis, SPECT/CT should be implemented as part of the routine diagnostic algorithm for patients with pain after primary TKA. LEVEL OF EVIDENCE II.
Collapse
Affiliation(s)
- Andreas M Murer
- Department of Orthopaedic Surgery and Traumatology, Kantonsspital Baselland (Bruderholz, Liestal, Laufen), 4101, Bruderholz, Switzerland
- University of Basel, Basel, Switzerland
| | - Michael T Hirschmann
- Department of Orthopaedic Surgery and Traumatology, Kantonsspital Baselland (Bruderholz, Liestal, Laufen), 4101, Bruderholz, Switzerland.
- University of Basel, Basel, Switzerland.
| | | | - Helmut Rasch
- Institute of Radiology and Nuclear Medicine, Kantonsspital Baselland, 4101, Bruderholz, Switzerland
| | - Rolf W Huegli
- Institute of Radiology and Nuclear Medicine, Kantonsspital Baselland, 4101, Bruderholz, Switzerland
- University of Basel, Basel, Switzerland
| |
Collapse
|
50
|
Ascione F, Braile A, Romano AM, di Giunta A, Masciangelo M, Senorsky EH, Samuelsson K, Marzano N. Experience-optimised fast track improves outcomes and decreases complications in total knee arthroplasty. Knee 2020; 27:500-508. [PMID: 31883758 DOI: 10.1016/j.knee.2019.11.002] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/12/2019] [Revised: 08/07/2019] [Accepted: 11/04/2019] [Indexed: 02/02/2023]
Abstract
PURPOSE The aim of this study was to describe an advanced total knee arthroplasty (TKA) fast-track programme and determine discharge parameters during hospitalisation, as well as patient satisfaction, outcomes and complications within the first 12 months after surgery. METHODS This prospective study was based on patients selected consecutively for primary elective TKA, undergoing surgery between 2014 and 2017 in an established fast-track setting. Hospitalisation-related parameters were collected: demographics, body mass index (BMI), surgical time, ischaemia time, haemoglobin values, blood transfusions, length of stay, weight-bearing and stair-climbing time, opioid administration, preoperative and discharge loss of extension and maximum active flexion of the knee, visual analogue scale (VAS), 12-month follow-up satisfaction rate and range of motion, any complications, hospital re-admission and re-operation within the first 12 months. Differences were determined using t-tests. RESULTS A total of 704 total knee replacements implanted in 481 patients were included in the study and 223 patients had a bilateral TKA. Their mean age was 69.8 years (range 57-88 years). At the 12-month follow-up, 623 patients (88.5%) reported being satisfied or very satisfied and 15 (2.1%) were dissatisfied with their TKA, mean active flexion and loss of extension were 104.4° and 2.3°, respectively. A total of 15 complications occurred (two percent): five painful knees, three knee stiffness, three haematomas, two infections, one hospital re-admission and one deep venous thrombosis. No cases of pulmonary embolism and death related to surgery were reported. CONCLUSION The study reports on an advanced fast-track programme for TKA with a low incidence of surgery- and hospitalisation-related issues and complications and without any severe adverse events during the first year. On average, the fast-track programme had a short length of stay, an early recovery of weight-bearing, knee mobility, pain control and a high satisfaction rate, accompanied with an acceptable 12 month range of motion.
Collapse
Affiliation(s)
- Francesco Ascione
- Department of Shoulder Surgery, Campolongo Hospital, Salerno, Italy; Department of Orthopaedic and Traumatology Surgery, Ospedale Buon Consiglio Fatebenefratelli, Napoli, Italy
| | - Adriano Braile
- Multidisciplinary Department of Orthopedic and Dentistry Specialties, Università della Campania "Luigi Vanvitelli", Napoli, Italy.
| | - Alfonso Maria Romano
- Department of Shoulder Surgery, Campolongo Hospital, Salerno, Italy; Department of Orthopaedic and Traumatology Surgery, Ospedale Buon Consiglio Fatebenefratelli, Napoli, Italy
| | - Angelo di Giunta
- Orthopaedic Division of Policlinico 'G.B. Morgagni', Catania, Italy
| | - Marco Masciangelo
- Orthopedics and Sport Medicine Unit, Casa di Cura 'Sileno e Anna Rizzola', San Donà di Piave, Venezia, Italy
| | - Eric Hamrin Senorsky
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden; Department of Orthopaedics, Sahlgrenska University Hospital, Mölndal, Sweden
| | - Kristian Samuelsson
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden; Department of Orthopaedics, Sahlgrenska University Hospital, Mölndal, Sweden
| | - Nicola Marzano
- Orthopedics and Sport Medicine Unit, Casa di Cura 'Sileno e Anna Rizzola', San Donà di Piave, Venezia, Italy
| |
Collapse
|