Torres-Claramunt R, Alós-Mairal J, Ibáñez M, Perelli S, Gelber P, Monllau JC. Clinical Outcomes After Polyurethane Meniscal Scaffolds Implantation Remain Stable Despite a Joint Space Narrowing at 10-Year Follow-Up.
Arthroscopy 2024;
40:1256-1261. [PMID:
37716635 DOI:
10.1016/j.arthro.2023.08.081]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/09/2022] [Revised: 08/23/2023] [Accepted: 08/28/2023] [Indexed: 09/18/2023]
Abstract
PURPOSE
To report the clinical outcomes, radiologic evolution, and survivorship of a series of patients affected by the postmeniscectomy syndrome and treated with a polyurethane scaffold at a minimum 10-year follow-up. In addition, the radiologic evolution of these patients was also assessed.
METHODS
All the patients operated on with a polyurethane meniscal scaffold implantation to treat postmeniscectomy syndrome from 2008 to 2011 were prospectively followed. Clinical evaluations and radiologic studies were assessed at the preoperative period, at 5-year follow-up, and at minimum 10-year follow-up. Clinical outcomes were based on patient-reported outcomes (e.g., the Knee injury and Osteoarthritis Outcome Score, International Knee Documentation Committee, Lysholm, and Tegner). Radiographical evaluation of the joint-space narrowing was done in the Rosenberg view. Failure was defined as patients who required surgery to remove the scaffold or those patients who needed surgery for a total or partial knee replacement.
RESULTS
Twenty-one of 27 patients, with a mean age of 56 ± 9.8 years, were available for the final follow-up. The mean follow-up was 11.8 (range, 10-12.7) years. Six patients were lost to follow-up. All functional scores showed a significant improvement (P < .001) at the 5- and 10-year follow-up. The exception was the Tegner score, which remained stable. The joint-space width was maintained from the preoperative period (1.9 ± 1.2 mm) up to the 5-year follow-up (1.3 ± 1.5 mm, P = .3) and decreased by the last evaluation (0.6 ± 1.2 mm, P = .001) at the last follow-up. Two (9.5%) of 21 patients were converted to a total knee replacement during the study period. None of the other patients needed revision surgery during the study period.
CONCLUSIONS
The polyurethane meniscal scaffold provides significant and stable pain relief over time and improved functional outcomes at a minimum of 10 years after surgery. However, degenerative changes progressed in the treated compartment, with a joint-space narrowing over the 10-year period.
LEVEL OF EVIDENCE
Level IV, retrospective case series.
Collapse