1
|
Farsang R, Kovács N, Szigeti M, Jankovics H, Vonderviszt F, Guttman A. Immobilized exoglycosidase matrix mediated solid phase glycan sequencing. Anal Chim Acta 2022; 1215:339906. [DOI: 10.1016/j.aca.2022.339906] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2022] [Revised: 04/27/2022] [Accepted: 05/01/2022] [Indexed: 11/29/2022]
|
2
|
Currivan SA, Chen WQ, Wilson R, Sanz Rodriguez E, Upadhyay N, Connolly D, Nesterenko PN, Paull B. Multi-lumen capillary based trypsin micro-reactor for the rapid digestion of proteins. Analyst 2018; 143:4944-4953. [PMID: 30221288 DOI: 10.1039/c8an01330f] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
In this work we evaluated a novel microreactor prepared using a surface modified, high surface-to-volume ratio multi-lumen fused silica capillary (MLC). The MLC investigated contained 126 parallel channels, each of 4 μm internal diameter. The MLC, along with conventional fused silica capillaries of 25 μm and 50 μm internal diameter, were treated by (3-aminopropyl)triethoxysilane (APTES) and then modified with gold nanoparticles, of ∼20 nm in diameter, to ultimately provide immobilisation sites for the proteolytic enzyme, trypsin. The modified capillaries and MLCs were characterised and profiled using non-invasive scanning capacitively coupled contactless conductivity detection (sC4D). The sC4D profiles confirmed a significantly higher amount of enzyme was immobilised to the MLC when compared to the fused silica capillaries, attributable to the increased surface to volume ratio. The MLC was used for dynamic protein digestion, where peptide fragments were collected and subjected to off-line chromatographic evaluation. The digestion was achieved with the MLC reactor, using a residence time of just 1.26 min, following which the HPLC peak associated with the intact protein decreased by >70%. The MLC reactors behaved similarly to the classical in vitro or in-solution approach, but provided a reduction in digestion time, and fewer peaks associated with trypsin auto-digestion, which is common using in-solution digestion. The digestion of cytochrome C using both the MLC-IMER and the in-solution approach, resulted in a sequence coverage of ∼80%. The preparation of the MLC microreactor was reproducible with <2.5% RSD between reactors (n = 3) as determined by sC4D.
Collapse
Affiliation(s)
- S A Currivan
- Australian Centre for Research on Separation Science, School of Natural Sciences, University of Tasmania, Tasmania, Australia.
| | | | | | | | | | | | | | | |
Collapse
|
3
|
Alharthi S, El Rassi Z. CE with multi-walled carbon nanotubes (MWCNTs). Part II. SDS coated functionalized MWCNTs as pseudo-stationary phases in nanoparticle EKC - Retention behaviors of small and large solutes. Talanta 2018; 192:545-552. [PMID: 30348428 DOI: 10.1016/j.talanta.2018.09.081] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2018] [Revised: 09/20/2018] [Accepted: 09/21/2018] [Indexed: 12/25/2022]
Abstract
In this study, functionalized multi-walled carbon nanotubes (MWCNTs), namely hydroxylated MWCNTs (MWCNT-OH), carboxylated MWCNTs (MWCNT-COOH) and sulfonated MWCNTs (MWCNT-SO3H) coated with sodium dodecyl sulfate (SDS) were demonstrated as effective pseudo-stationary phases (PSPs) in the separation of various species by the nanoparticle capillary electrokinetic chromatography (NPEKC) mode of capillary electrophoresis (CE). Due to the significant increase in their surface charge density in the presence of SDS, the three SDS coated MWCNTs yielded high performance separation for herbicides, barbiturates, dansyl-DL-amino acids (Dns-AAs), dipeptides and proteins by NPEKC. In addition, high resolution tryptic peptide maps of three standard proteins including myoglobin, cytochrome C and lysozyme were readily obtained. The three PSPs systems yielded high plate numbers that spanned a wide range of values depending on the type of species. The values of the observed selectivity factors (i.e., α values) were significantly different among the three PSPs for solutes that underwent strong interactions with the SDS coated functionalized MWCNTs while for negatively charged solutes (e.g., Dns-AAs) of the same charge sign as the PSPs the α values were about the same on the three different PSPs indicating weak association with the PSPs and signaling separation based chiefly on the differences in electro-migration arising from differences in charge-to-mass ratios.
Collapse
Affiliation(s)
- Sarah Alharthi
- Department of Chemistry, Oklahoma State University, Stillwater, OK 74078-3071, USA
| | - Ziad El Rassi
- Department of Chemistry, Oklahoma State University, Stillwater, OK 74078-3071, USA.
| |
Collapse
|
4
|
Measurement of impurities to support process development and manufacture of biopharmaceuticals. Trends Analyt Chem 2018. [DOI: 10.1016/j.trac.2017.10.026] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
5
|
Yang JS, Qiao J, Kim JY, Zhao L, Qi L, Moon MH. Online Proteolysis and Glycopeptide Enrichment with Thermoresponsive Porous Polymer Membrane Reactors for Nanoflow Liquid Chromatography-Tandem Mass Spectrometry. Anal Chem 2018; 90:3124-3131. [DOI: 10.1021/acs.analchem.7b04273] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Affiliation(s)
- Joon Seon Yang
- Department of Chemistry, Yonsei University, 50 Yonsei-Ro, Seoul 03722, South Korea
| | - Juan Qiao
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, No. 2 Zhongguancun Beiyijie, Beijing 100190, P. R. China
- University of Chinese Academy of Sciences, No. 19A Yuquan Road, Beijing 100049, P. R. China
| | - Jin Yong Kim
- Department of Chemistry, Yonsei University, 50 Yonsei-Ro, Seoul 03722, South Korea
| | - Liping Zhao
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, No. 2 Zhongguancun Beiyijie, Beijing 100190, P. R. China
- College of Chemistry & Environmental Science, Hebei University, No. 180 Wusidong Road, Baoding 071002, P. R. China
| | - Li Qi
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, No. 2 Zhongguancun Beiyijie, Beijing 100190, P. R. China
- University of Chinese Academy of Sciences, No. 19A Yuquan Road, Beijing 100049, P. R. China
| | - Myeong Hee Moon
- Department of Chemistry, Yonsei University, 50 Yonsei-Ro, Seoul 03722, South Korea
| |
Collapse
|
6
|
Skjærvø Ø, Halvorsen TG, Reubsaet L. Smart blood spots for whole blood protein analysis. Analyst 2018; 143:3184-3190. [DOI: 10.1039/c8an00317c] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
A reactor for whole blood sampling integrated with instant protein digestion in a “lab-on-paper” format is introduced here.
Collapse
Affiliation(s)
- Øystein Skjærvø
- Department of Pharmaceutical Chemistry
- School of Pharmacy
- University of Oslo
- NO-0316 Oslo
- Norway
| | | | - Léon Reubsaet
- Department of Pharmaceutical Chemistry
- School of Pharmacy
- University of Oslo
- NO-0316 Oslo
- Norway
| |
Collapse
|
7
|
Brandtzaeg OK, Røen BT, Enger S, Lundanes E, Wilson SR. Multichannel Open Tubular Enzyme Reactor Online Coupled with Mass Spectrometry for Detecting Ricin. Anal Chem 2017; 89:8667-8673. [PMID: 28783436 DOI: 10.1021/acs.analchem.7b02590] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
For counterterrorism purposes, a selective nano liquid chromatography-mass spectrometry (nanoLC-MS) platform was developed for detecting the highly lethal protein ricin from castor bean extract. Manual sample preparation steps were omitted by implementing a trypsin/Lys-C enzyme-immobilized multichannel reactor (MCR) consisting of 126 channels (8 μm inner diameter in all channels) that performed online digestion of proteins (5 min reaction time, instead of 4-16 h in previous in-solution methods). Reduction and alkylation steps were not required. The MCR allowed identification of ricin by signature peptides in all targeted mode injections performed, with a complete absence of carry-over in blank injections. The MCRs (interior volume ≈ 1 μL) have very low backpressure, allowing for trivial online coupling with commercial nanoLC-MS systems. The open tubular nature of the MCRs allowed for repeatable within/between-reactor preparation and performance.
Collapse
Affiliation(s)
| | - Bent-Tore Røen
- Norwegian Defence Research Establishment (FFI) , P.O. Box 25, N-2027 Kjeller, Norway
| | - Siri Enger
- Norwegian Defence Research Establishment (FFI) , P.O. Box 25, N-2027 Kjeller, Norway
| | - Elsa Lundanes
- Department of Chemistry, University of Oslo , P.O. Box 1033, Blindern, NO-0315 Oslo, Norway
| | - Steven Ray Wilson
- Department of Chemistry, University of Oslo , P.O. Box 1033, Blindern, NO-0315 Oslo, Norway
| |
Collapse
|
8
|
Foo HC, Smith NW, Stanley SM. Fabrication of an on-line enzyme micro-reactor coupled to liquid chromatography–tandem mass spectrometry for the digestion of recombinant human erythropoietin. Talanta 2015; 135:18-22. [DOI: 10.1016/j.talanta.2014.12.033] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2014] [Revised: 12/19/2014] [Accepted: 12/20/2014] [Indexed: 11/30/2022]
|
9
|
Hustoft HK, Vehus T, Brandtzaeg OK, Krauss S, Greibrokk T, Wilson SR, Lundanes E. Open tubular lab-on-column/mass spectrometry for targeted proteomics of nanogram sample amounts. PLoS One 2014; 9:e106881. [PMID: 25222838 PMCID: PMC4164520 DOI: 10.1371/journal.pone.0106881] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2014] [Accepted: 08/09/2014] [Indexed: 12/28/2022] Open
Abstract
A novel open tubular nanoproteomic platform featuring accelerated on-line protein digestion and high-resolution nano liquid chromatography mass spectrometry (LC-MS) has been developed. The platform features very narrow open tubular columns, and is hence particularly suited for limited sample amounts. For enzymatic digestion of proteins, samples are passed through a 20 µm inner diameter (ID) trypsin + endoproteinase Lys-C immobilized open tubular enzyme reactor (OTER). Resulting peptides are subsequently trapped on a monolithic pre-column and transferred on-line to a 10 µm ID porous layer open tubular (PLOT) liquid chromatography LC separation column. Wnt/ß-catenein signaling pathway (Wnt-pathway) proteins of potentially diagnostic value were digested+detected in targeted-MS/MS mode in small cell samples and tumor tissues within 120 minutes. For example, a potential biomarker Axin1 was identifiable in just 10 ng of sample (protein extract of ∼1,000 HCT15 colon cancer cells). In comprehensive mode, the current OTER-PLOT set-up could be used to identify approximately 1500 proteins in HCT15 cells using a relatively short digestion+detection cycle (240 minutes), outperforming previously reported on-line digestion/separation systems. The platform is fully automated utilizing common commercial instrumentation and parts, while the reactor and columns are simple to produce and have low carry-over. These initial results point to automated solutions for fast and very sensitive MS based proteomics, especially for samples of limited size.
Collapse
Affiliation(s)
| | - Tore Vehus
- Department of Chemistry, University of Oslo, Oslo, Norway
| | | | - Stefan Krauss
- Unit for Cell Signaling, Cancer Stem Cell Innovation Center, Oslo University Hospital, Oslo, Norway
| | - Tyge Greibrokk
- Department of Chemistry, University of Oslo, Oslo, Norway
| | | | - Elsa Lundanes
- Department of Chemistry, University of Oslo, Oslo, Norway
| |
Collapse
|
10
|
Safdar M, Sproß J, Jänis J. Microscale immobilized enzyme reactors in proteomics: Latest developments. J Chromatogr A 2014; 1324:1-10. [DOI: 10.1016/j.chroma.2013.11.045] [Citation(s) in RCA: 60] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2013] [Revised: 11/18/2013] [Accepted: 11/24/2013] [Indexed: 01/10/2023]
|
11
|
Nunes-Miranda JD, Núñez C, Santos HM, Vale G, Reboiro-Jato M, Fdez-Riverola F, Lodeiro C, Miró M, Capelo JL. A mesofluidic platform integrating on-chip probe ultrasonication for multiple sample pretreatment involving denaturation, reduction, and digestion in protein identification assays by mass spectrometry. Analyst 2014; 139:992-5. [DOI: 10.1039/c3an02178e] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
A novel mesofluidic platform integrating on-chip probe ultrasonication for automated high-throughput shotgun proteomic assays.
Collapse
Affiliation(s)
- J. D. Nunes-Miranda
- Department of Genetics and Biotechnology
- University of Trás-os-Montes and Alto Douro
- Vila Real, Portugal
- Institute for Biotechnology and Bioengineering
- Centre of Genomics and Biotechnology
| | - Cristina Núñez
- REQUIMTE
- Departamento de Química
- Faculdade de Ciencias e Tecnologia
- FCT
- Universidade Nova de Lisboa
| | - Hugo M. Santos
- Institute for Biotechnology and Bioengineering
- Centre of Genomics and Biotechnology
- University of Trás-os-Montes and Alto Douro
- Vila Real, Portugal
- REQUIMTE
| | - G. Vale
- REQUIMTE
- Departamento de Química
- Faculdade de Ciencias e Tecnologia
- FCT
- Universidade Nova de Lisboa
| | - Miguel Reboiro-Jato
- SING Group
- Informatics Department
- Higher Technical School of Computer Engineering
- University of Vigo
- Ourense, Spain
| | - Florentino Fdez-Riverola
- SING Group
- Informatics Department
- Higher Technical School of Computer Engineering
- University of Vigo
- Ourense, Spain
| | - Carlos Lodeiro
- REQUIMTE
- Departamento de Química
- Faculdade de Ciencias e Tecnologia
- FCT
- Universidade Nova de Lisboa
| | - Manuel Miró
- FI-TRACE Group
- Department of Chemistry
- University of the Balearic Islands
- Palma de Mallorca, Spain
| | - J. L. Capelo
- REQUIMTE
- Departamento de Química
- Faculdade de Ciencias e Tecnologia
- FCT
- Universidade Nova de Lisboa
| |
Collapse
|
12
|
Hustoft HK, Brandtzaeg OK, Rogeberg M, Misaghian D, Torsetnes SB, Greibrokk T, Reubsaet L, Wilson SR, Lundanes E. Integrated enzyme reactor and high resolving chromatography in "sub-chip" dimensions for sensitive protein mass spectrometry. Sci Rep 2013; 3:3511. [PMID: 24336509 PMCID: PMC3863811 DOI: 10.1038/srep03511] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2013] [Accepted: 11/28/2013] [Indexed: 12/29/2022] Open
Abstract
Reliable, sensitive and automatable analytical methodology is of great value in e.g. cancer diagnostics. In this context, an on-line system for enzymatic cleavage of proteins, subsequent peptide separation by liquid chromatography (LC) with mass spectrometric detection has been developed using "sub-chip" columns (10-20 μm inner diameter, ID). The system could detect attomole amounts of isolated cancer biomarker progastrin-releasing peptide (ProGRP), in a more automatable fashion compared to previous methods. The workflow combines protein digestion using an 20 μm ID immobilized trypsin reactor with a polymeric layer of 2-hydroxyethyl methacrylate-vinyl azlactone (HEMA-VDM), desalting on a polystyrene-divinylbenzene (PS-DVB) monolithic trap column, and subsequent separation of resulting peptides on a 10 μm ID (PS-DVB) porous layer open tubular (PLOT) column. The high resolution of the PLOT columns was maintained in the on-line system, resulting in narrow chromatographic peaks of 3-5 seconds. The trypsin reactors provided repeatable performance and were compatible with long-term storage.
Collapse
Affiliation(s)
- Hanne Kolsrud Hustoft
- Department of Chemistry, University of Oslo, Post Box 1033 Blindern, NO-0315 Oslo, Norway
| | | | - Magnus Rogeberg
- Department of Chemistry, University of Oslo, Post Box 1033 Blindern, NO-0315 Oslo, Norway
- Department of Neurology, Akershus University Hospital, 1478 Lørenskog, Norway
| | - Dorna Misaghian
- Department of Chemistry, University of Oslo, Post Box 1033 Blindern, NO-0315 Oslo, Norway
| | - Silje Bøen Torsetnes
- School of Pharmacy, University of Oslo, Post Box 1068 Blindern, NO-0316 Oslo, Norway
| | - Tyge Greibrokk
- Department of Chemistry, University of Oslo, Post Box 1033 Blindern, NO-0315 Oslo, Norway
| | - Léon Reubsaet
- School of Pharmacy, University of Oslo, Post Box 1068 Blindern, NO-0316 Oslo, Norway
| | - Steven Ray Wilson
- Department of Chemistry, University of Oslo, Post Box 1033 Blindern, NO-0315 Oslo, Norway
| | - Elsa Lundanes
- Department of Chemistry, University of Oslo, Post Box 1033 Blindern, NO-0315 Oslo, Norway
| |
Collapse
|
13
|
Safdar M, Spross J, Jänis J. Microscale enzyme reactors comprising gold nanoparticles with immobilized trypsin for efficient protein digestion. JOURNAL OF MASS SPECTROMETRY : JMS 2013; 48:1281-1284. [PMID: 24338882 DOI: 10.1002/jms.3297] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/12/2013] [Revised: 10/11/2013] [Accepted: 10/15/2013] [Indexed: 06/03/2023]
Affiliation(s)
- Muhammad Safdar
- Department of Chemistry, University of Eastern Finland, Yliopistokatu 7, FI-80101, Joensuu, Finland
| | | | | |
Collapse
|
14
|
Cheong WJ, Ali F, Kim YS, Lee JW. Comprehensive overview of recent preparation and application trends of various open tubular capillary columns in separation science. J Chromatogr A 2013; 1308:1-24. [DOI: 10.1016/j.chroma.2013.07.107] [Citation(s) in RCA: 68] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2013] [Revised: 07/26/2013] [Accepted: 07/31/2013] [Indexed: 12/15/2022]
|
15
|
Homaei AA, Sariri R, Vianello F, Stevanato R. Enzyme immobilization: an update. J Chem Biol 2013; 6:185-205. [PMID: 24432134 DOI: 10.1007/s12154-013-0102-9] [Citation(s) in RCA: 495] [Impact Index Per Article: 45.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2013] [Accepted: 07/31/2013] [Indexed: 11/25/2022] Open
Abstract
Compared to free enzymes in solution, immobilized enzymes are more robust and more resistant to environmental changes. More importantly, the heterogeneity of the immo-bilized enzyme systems allows an easy recovery of both enzymes and products, multiple re-use of enzymes, continuous operation of enzymatic processes, rapid termination of reactions, and greater variety of bioreactor designs. This paper is a review of the recent literatures on enzyme immobilization by various techniques, the need for immobilization and different applications in industry, covering the last two decades. The most recent papers, patents, and reviews on immobilization strategies and application are reviewed.
Collapse
Affiliation(s)
- Ahmad Abolpour Homaei
- Department of Biology, Faculty of Science, University of Hormozgan, Bandarabbas, Iran
| | - Reyhaneh Sariri
- Reyhaneh Sariri, Department of Microbiology, Lahijan Branch, Islamic Azad University, Lahijan, Iran
| | - Fabio Vianello
- Department of Comparative Biomedicine and Food Science, University of Padua, Padua, Italy
| | - Roberto Stevanato
- Department of Molecular Sciences and Nanosystems, University of Venice, Venice, Italy
| |
Collapse
|
16
|
Capillary electrophoresis applied to screening of trypsin inhibitors using microreactor with trypsin immobilized by glutaraldehyde. Anal Biochem 2013; 438:32-8. [DOI: 10.1016/j.ab.2013.03.010] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2012] [Revised: 03/09/2013] [Accepted: 03/11/2013] [Indexed: 11/19/2022]
|
17
|
Kim JY, Lee SY, Kim SK, Park SR, Kang D, Moon MH. Development of an Online Microbore Hollow Fiber Enzyme Reactor Coupled with Nanoflow Liquid Chromatography-Tandem Mass Spectrometry for Global Proteomics. Anal Chem 2013; 85:5506-13. [DOI: 10.1021/ac400625k] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Affiliation(s)
- Jin Yong Kim
- Department of Chemistry, Yonsei University, Seoul, 120-749, Korea
| | - Sun Young Lee
- Center for Bioanalysis, Division
of Metrology for Quality of Life, Korea Research Institute of Standards and Science, Daejeon, 305-340, Korea
| | - Sook-Kyung Kim
- Center for Bioanalysis, Division
of Metrology for Quality of Life, Korea Research Institute of Standards and Science, Daejeon, 305-340, Korea
| | - Sang Ryoul Park
- Center for Bioanalysis, Division
of Metrology for Quality of Life, Korea Research Institute of Standards and Science, Daejeon, 305-340, Korea
| | - Dukjin Kang
- Center for Bioanalysis, Division
of Metrology for Quality of Life, Korea Research Institute of Standards and Science, Daejeon, 305-340, Korea
| | - Myeong Hee Moon
- Department of Chemistry, Yonsei University, Seoul, 120-749, Korea
| |
Collapse
|
18
|
Luk VN, Fiddes LK, Luk VM, Kumacheva E, Wheeler AR. Digital microfluidic hydrogel microreactors for proteomics. Proteomics 2012; 12:1310-8. [PMID: 22589180 DOI: 10.1002/pmic.201100608] [Citation(s) in RCA: 52] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Proteolytic digestion is an essential step in proteomic sample processing. While this step has traditionally been implemented in homogeneous (solution) format, there is a growing trend to use heterogeneous systems in which the enzyme is immobilized on hydrogels or other solid supports. Here, we introduce the use of immobilized enzymes in hydrogels for proteomic sample processing in digital microfluidic (DMF) systems. In this technique, preformed cylindrical agarose discs bearing immobilized trypsin or pepsin were integrated into DMF devices. A fluorogenic assay was used to optimize the covalent modification procedure for enzymatic digestion efficiency, with maximum efficiency observed at 31 μg trypsin in 2-mm diameter agarose gel discs. Gel discs prepared in this manner were used in an integrated method in which proteomic samples were sequentially reduced, alkylated, and digested, with all sample and reagent handling controlled by DMF droplet operation. Mass spectrometry analysis of the products revealed that digestion using the trypsin gel discs resulted in higher sequence coverage in model analytes relative to conventional homogenous processing. Proof-of-principle was demonstrated for a parallel digestion system in which a single sample was simultaneously digested on multiple gel discs bearing different enzymes. We propose that these methods represent a useful new tool for the growing trend toward miniaturization and automation in proteomic sample processing.
Collapse
Affiliation(s)
- Vivienne N Luk
- Department of Chemistry, University of Toronto, Toronto, ON, Canada
| | | | | | | | | |
Collapse
|
19
|
Çelebi B, Bayraktar A, Tuncel A. Synthesis of a monolithic, micro-immobilised enzyme reactor via click-chemistry. Anal Bioanal Chem 2012; 403:2655-63. [DOI: 10.1007/s00216-012-6075-7] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2011] [Revised: 04/19/2012] [Accepted: 04/21/2012] [Indexed: 10/28/2022]
|
20
|
Yu Z, Chen LC, Mandal MK, Nonami H, Erra-Balsells R, Hiraoka K. Online electrospray ionization mass spectrometric monitoring of protease-catalyzed reactions in real time. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2012; 23:728-735. [PMID: 22314937 DOI: 10.1007/s13361-011-0323-5] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/12/2011] [Revised: 12/10/2011] [Accepted: 12/18/2011] [Indexed: 05/31/2023]
Abstract
Although there are a lot of well established methods for monitoring enzyme-catalyzed reactions, most of them are based on changes in spectroscopic properties during the conversion of substrates to products. However, reactions without optical changes are common, which are inapplicable to these spectroscopic methods. As an alternative technique for enzymologic research, mass spectrometry (MS) is favored due to its specificity, sensitivity, and the ability to obtain stoichiometric information. In this work, probe electrospray ionization (PESI) source coupled with a time of flight mass spectrometer was employed to monitor some typical protease-catalyzed reactions, including pepsinolysis and trypsinolysis of cytochrome c in real time. Due to the high electrical conductivity of each reaction system, corona discharges are likely to occur, which would decrease intensities of mass spectrometric signals. An ultra-fine sampling probe and an auxiliary vapor spray were adopted to prevent corona discharges. Experimental results from peptic and tryptic digestions of cytochrome c showed different and characteristic catalytic pathways. With the data presented in this study, PESI-MS can be considered as a potential tool for real-time monitoring of enzymatic reactions because of its simplicity in instrumental configuration, wide applicability under harsh conditions, and flexibility in combination with other techniques.
Collapse
Affiliation(s)
- Zhan Yu
- Clean Energy Research Center, University of Yamanashi, 4-3-11 Takeda, Kofu Yamanashi, 400-8511, Japan
| | | | | | | | | | | |
Collapse
|
21
|
Immobilized trypsin on epoxy organic monoliths with modulated hydrophilicity: Novel bioreactors useful for protein analysis by liquid chromatography coupled to tandem mass spectrometry. J Chromatogr A 2011; 1218:8937-45. [DOI: 10.1016/j.chroma.2011.05.059] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2011] [Revised: 05/16/2011] [Accepted: 05/17/2011] [Indexed: 10/18/2022]
|
22
|
Ghasemi M, Minier MJG, Tatoulian M, Chehimi MM, Arefi-Khonsari F. Ammonia Plasma Treated Polyethylene Films for Adsorption or Covalent Immobilization of Trypsin: Quantitative Correlation between X-ray Photoelectron Spectroscopy Data and Enzyme Activity. J Phys Chem B 2011; 115:10228-38. [DOI: 10.1021/jp204097a] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Affiliation(s)
- Mahsa Ghasemi
- Chimie ParisTech, Laboratoire de Génie des Procédés Plasma et Traitements de Surface (LGPPTS), EA 3492, 75005 Paris, France
- UPMC Univ Paris 06, 75005 Paris, France
- Chimie ParisTech, Laboratoire Charles Friedel (LCF), 75005 Paris, France
- CNRS, UMR 7223, 75005 Paris, France
| | - Michel J. G. Minier
- Chimie ParisTech, Laboratoire Charles Friedel (LCF), 75005 Paris, France
- CNRS, UMR 7223, 75005 Paris, France
| | - Michaël Tatoulian
- Chimie ParisTech, Laboratoire de Génie des Procédés Plasma et Traitements de Surface (LGPPTS), EA 3492, 75005 Paris, France
- UPMC Univ Paris 06, 75005 Paris, France
| | - Mohamed M. Chehimi
- Interfaces, Traitements, Organisation & Dynamique des Systèmes (ITODYS Lab), University Paris Diderot & CNRS, 15 rue Jean-Antoine de Baïf, 75013 Paris, France
| | - Farzaneh Arefi-Khonsari
- Chimie ParisTech, Laboratoire de Génie des Procédés Plasma et Traitements de Surface (LGPPTS), EA 3492, 75005 Paris, France
- UPMC Univ Paris 06, 75005 Paris, France
| |
Collapse
|
23
|
Kataoka H, Saito K. Recent advances in SPME techniques in biomedical analysis. J Pharm Biomed Anal 2011; 54:926-50. [DOI: 10.1016/j.jpba.2010.12.010] [Citation(s) in RCA: 143] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2010] [Revised: 12/06/2010] [Accepted: 12/09/2010] [Indexed: 10/18/2022]
|
24
|
Jun SH, Chang MS, Kim BC, An HJ, Lopez-Ferrer D, Zhao R, Smith RD, Lee SW, Kim J. Trypsin coatings on electrospun and alcohol-dispersed polymer nanofibers for a trypsin digestion column. Anal Chem 2011; 82:7828-34. [PMID: 20718428 DOI: 10.1021/ac101633e] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
The construction of a trypsin column for rapid and efficient protein digestion in proteomics is described. Electrospun and alcohol-dispersed polymer nanofibers were used for the fabrication of highly stable trypsin coatings, which were prepared by a two-step process of covalent attachment and enzyme cross-linking. In a comparative study with the trypsin coatings on as-spun and nondispersed nanofibers, it has been observed that a simple step of alcohol dispersion improved not only the enzyme loading but also the performance of protein digestion. In-column digestion of enolase was successfully performed in less than 20 min. By applying the alcohol dispersion of polymer nanofibers, the bypass of samples was reduced by filling up the column with well-dispersed nanofibers, and subsequently, interactions between the protein and the trypsin coatings were improved, yielding more complete and reproducible digestions. Regardless of alcohol dispersion or not, trypsin coatings showed better digestion performance and improved performance stability under recycled uses than covalently attached trypsin, in-solution digestion, and commercial trypsin beads. The combination of highly stable trypsin coatings and alcohol dispersion of polymer nanofibers has opened up a new potential to develop a trypsin column for online and automated protein digestion.
Collapse
Affiliation(s)
- Seung-Hyun Jun
- Department of Chemical and Biological Engineering, Korea University, 1, 5-ka, Anam-dong, Seongbuk-gu, Seoul 136-701, Republic of Korea
| | | | | | | | | | | | | | | | | |
Collapse
|
25
|
Reid CQ, Tait A, Baldascini H, Mohindra A, Racher A, Bilsborough S, Smales CM, Hoare M. Rapid whole monoclonal antibody analysis by mass spectrometry: An ultra scale-down study of the effect of harvesting by centrifugation on the post-translational modification profile. Biotechnol Bioeng 2010; 107:85-95. [PMID: 20506289 DOI: 10.1002/bit.22790] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
Abstract
With the trend towards the generation and production of increasing numbers of complex biopharmaceutical (protein based) products, there is an increased need and requirement to characterize both the product and production process in terms of robustness and reproducibility. This is of particular importance for products from mammalian cell culture which have large molecular structures and more often than not complex post-translational modifications (PTMs) that can impact the efficacy, stability and ultimately the safety of the final product. It is therefore vital to understand how the operating conditions of a bioprocess affect the distribution and make up of these PTMs to ensure a consistent quality and activity in the final product. Here we have characterized a typical bioprocess and determined (a) how the time of harvest from a mammalian cell culture and, (b) through the use of an ultra scale-down mimic how the nature of the primary recovery stages, affect the distribution and make up of the PTMs observed on a recombinant IgG(4) monoclonal antibody. In particular we describe the use of rapid whole antibody analysis by mass spectrometry to analyze simultaneously the changes that occur to the cleavage of heavy chain C-terminal lysine residues and the glycosylation pattern, as well as the presence of HL dimers. The time of harvest was found to have a large impact upon the range of glycosylation patterns observed, but not upon C-terminal lysine cleavage. The culture age had a profound impact on the ratio of different glycan moieties found on antibody molecules. The proportion of short glycans increased (e.g., (G0F)(2) 20-35%), with an associated decrease in the proportion of long glycans with culture age (e.g., (G2F)(2) 7-4%, and G1F/G2F from 15.2% to 7.8%). Ultra scale-down mimics showed that subsequent processing of these cultures did not change the post-translational modifications investigated, but did increase the proportion of half antibodies present in the process stream. The combination of ultra scale-down methodology and whole antibody analysis by mass spectrometry has demonstrated that the effects of processing on the detailed molecular structure of a monoclonal antibody can be rapidly determined early in the development process. In this study we have demonstrated this analysis to be applicable to critical process design decisions (e.g., time of harvest) in terms of achieving a desired molecular structure, but this approach could also be applied as a selection criterion as to the suitability of a platform process for the preparation of a new drug candidate. Also the methodology provides means for bioprocess engineers to predict at the discovery phase how a bioprocess will impact upon the quality of the final product.
Collapse
Affiliation(s)
- C Q Reid
- Department of Biochemical Engineering, University College London, UK
| | | | | | | | | | | | | | | |
Collapse
|
26
|
Zhou J. Fast trypsin digestion of proteins on a cross-linked [Os(dmebpy)(2)Cl](+/2+)-derivatized copolymer of acrylamide and vinylimidazole column. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2010; 24:2236-2244. [PMID: 20607841 DOI: 10.1002/rcm.4635] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
Fast digestion of proteins was observed when they were loaded together with trypsin onto the cross-linked [Os(dmebpy)(2)Cl](+/2+)-derivatized copolymer of acrylamide and vinylimidazole column. The insoluble Os-complexed polymer particles were packed into an electrospray tip to monitor peptides eluted during loading, washing and elution periods with a mass spectrometer. The proteolytic cleavage of proteins was observed immediately when the mixture of trypsin and substrates in 0.2 mM ammonium bicarbonate 50:50 H(2)O/acetonitrile reached the column tip, and continued through the loading period. Some tryptic peptides were released from the column during the loading and following washing periods. The others still stayed on the column until the low pH elution buffer reached the column. If a protein was first loaded onto the column, no tryptic peptides of the protein were observed when trypsin was loaded later for the on-column digestion. Only the autolysis peptides of trypsin were observed. On-column digestion of 100 fmol myoglobin was successfully detected with a low sensitivity quadrupole mass spectrometer. A hybrid Os-polymer/C(18) column tip was constructed for the online trypsin digestion of proteins in the aqueous buffers and the following trapping and elution of peptides from the C(18) column. The digestion of reduced and alkylated bovine serum albumin and human transferrin in 2.5 mM ammonium bicarbonate and 0.2 M urea buffer was observed on the column, with more peptide coverage than conventional 4 h in-solution digestion at 37 degrees C. Control experiments without the Os-polymer in the column tip excluded the spontaneous in-solution digestion of proteins in the short time window of buffer delivery onto the column, indirectly confirming the contribution of Os-polymer on the fast trypsin digestion.
Collapse
Affiliation(s)
- Jie Zhou
- The Beckman Institute, California Institute of Technology, Pasadena, CA 91125, USA.
| |
Collapse
|
27
|
Kataoka H, Ishizaki A, Nonaka Y, Saito K. Developments and applications of capillary microextraction techniques: A review. Anal Chim Acta 2009; 655:8-29. [DOI: 10.1016/j.aca.2009.09.032] [Citation(s) in RCA: 147] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2009] [Revised: 09/19/2009] [Accepted: 09/22/2009] [Indexed: 11/30/2022]
|
28
|
|
29
|
Stigter E, de Jong G, van Bennekom W. Development of an on-line SPR-digestion-nanoLC-MS/MS system for the quantification and identification of interferon-γ in plasma. Biosens Bioelectron 2009; 24:2184-90. [DOI: 10.1016/j.bios.2008.11.020] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2008] [Revised: 10/29/2008] [Accepted: 11/20/2008] [Indexed: 01/01/2023]
|
30
|
|
31
|
Rich RL, Myszka DG. Survey of the year 2007 commercial optical biosensor literature. J Mol Recognit 2008; 21:355-400. [DOI: 10.1002/jmr.928] [Citation(s) in RCA: 144] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
32
|
A set of serine proteinase paralogs are required for blood-digestion in the ixodid tick Haemaphysalis longicornis. Parasitol Int 2008; 57:499-505. [PMID: 18775510 DOI: 10.1016/j.parint.2008.08.003] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2008] [Revised: 07/10/2008] [Accepted: 08/06/2008] [Indexed: 11/23/2022]
Abstract
We present evidence demonstrating that genes encoding enzymes essential for successful blood-feeding are differentially induced in the midgut of the hard tick Haemaphysalis longicornis. Three serine proteinase genes (HlSP, HlSP2 and HlSP3) isolated from H. longicornis midgut exhibit protein sequence similarity with other trypsin-like serine proteinases reported from arthropods and vertebrate animal species. The endogenous enzymes were mainly detected in the midgut epithelial cells and in the lumen of an adult tick. The recombinant enzymes expressed in Escherichia coli efficiently hydrolyzed synthetic substrates specific for serine proteinases over a broad range of pH and temperature values. Notably, the transcript levels of HlSP2 and HlSP3 were detected to significantly increase at 96 h post infestation, while the transcript of HlSP was induced in the earlier stage of blood-feeding. Further, silencing of HlSP, HlSP2 and HlSP3 genes by RNA interference led to a significant reductions in the engorged tick body weight, suggesting synergetic roles of these serine proteinases in blood-feeding and digestion.
Collapse
|
33
|
Pepsin immobilized in dextran-modified fused-silica capillaries for on-line protein digestion and peptide mapping. Anal Chim Acta 2008; 619:231-8. [DOI: 10.1016/j.aca.2008.04.060] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/29/2008] [Revised: 04/27/2008] [Accepted: 04/28/2008] [Indexed: 11/21/2022]
|
34
|
Vukovic J, Loftheim H, Winther B, Reubsaet JLE. Improving off-line accelerated tryptic digestion. J Chromatogr A 2008; 1195:34-43. [DOI: 10.1016/j.chroma.2008.05.010] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2008] [Revised: 03/28/2008] [Accepted: 05/08/2008] [Indexed: 11/16/2022]
|