1
|
Andrianova MS, Kuznetsov EV, Grudtsov VP, Kuznetsov AE. CMOS-compatible biosensor for L-carnitine detection. Biosens Bioelectron 2018; 119:48-54. [PMID: 30098466 DOI: 10.1016/j.bios.2018.07.044] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2018] [Revised: 07/11/2018] [Accepted: 07/22/2018] [Indexed: 02/07/2023]
Abstract
A CMOS-compatible ISFET with a Ta2O5 sensitive surface was developed. The structure was optimized for achieving high sensitivity using a subthreshold operation mode and by reducing the influence of the capacitances on the value of subthreshold swing. The developed ISFET was used as a basis for a biosensor for L-carnitine detection. To this end, carnitine acetyltransferase was immobilized on the ISFET sensitive surface. The immobilized enzyme was active (0.082 U/g model plate). The complete microsystem, consisting of a packaged chip, an immobilized enzyme and a microfluidic channel, detected L-carnitine at a range of 0.2-100 μM with a LOD of 0.2 μM. The biosensor response was linear in the range of 0.2-50 μM of L-carnitine with sensitivity 18.0 ± 1.7 mV/μM. An experiment with artificial urine containing 1.3 μM L-carnitine showed that the proposed biosensor could be used on a real sample. Therefore, a new sensor specially optimized for biosensing CMOS-compatible ISFET structures and direct determination of L-carnitine with immobilized carnitine acetyltransferase was developed.
Collapse
Affiliation(s)
- M S Andrianova
- Scientific-Manufacturing Complex Technological Centre, 124498, Shokina square, h. 1, bld. 7, Zelenograd, Moscow, Russia.
| | - E V Kuznetsov
- Scientific-Manufacturing Complex Technological Centre, 124498, Shokina square, h. 1, bld. 7, Zelenograd, Moscow, Russia
| | - V P Grudtsov
- Scientific-Manufacturing Complex Technological Centre, 124498, Shokina square, h. 1, bld. 7, Zelenograd, Moscow, Russia
| | - A E Kuznetsov
- Scientific-Manufacturing Complex Technological Centre, 124498, Shokina square, h. 1, bld. 7, Zelenograd, Moscow, Russia
| |
Collapse
|
2
|
Rodrigues KT, Cieslarová Z, Tavares MFM, Simionato AVC. Strategies Involving Mass Spectrometry Combined with Capillary Electrophoresis in Metabolomics. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2017; 965:99-141. [DOI: 10.1007/978-3-319-47656-8_5] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
|
3
|
Development of solid phase extraction strategies to minimize the effect of human urine matrix effect on the response of carnitine by UPLC–MS/MS. Microchem J 2016. [DOI: 10.1016/j.microc.2016.07.018] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
|
4
|
Abstract
In clinical metabolomics, capillary electrophoresis-mass spectrometry (CE-MS) has become a very useful technique for the analysis of highly polar and charged metabolites in complex biologic samples. A comprehensive overview of recent developments in CE-MS for metabolic profiling studies is presented. This review covers theory, CE separation modes, capillary coatings, and practical aspects of CE-MS coupling. Attention is also given to sample pretreatment and data analysis strategies used for metabolomics. The applicability of CE-MS for clinical metabolomics is illustrated using samples ranging from plasma and urine to cells and tissues. CE-MS application to large-scale and quantitative clinical metabolomics is addressed. Conclusions and perspectives on this unique analytic strategy are presented.
Collapse
|
5
|
Analytical approaches to determination of carnitine in biological materials, foods and dietary supplements. Food Chem 2014; 142:220-32. [DOI: 10.1016/j.foodchem.2013.06.137] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2012] [Revised: 05/24/2013] [Accepted: 06/26/2013] [Indexed: 12/30/2022]
|
6
|
Isaguirre AC, Olsina RA, Martinez LD, Lapierre AV, Cerutti S. Rapid and sensitive HILIC–MS/MS analysis of carnitine and acetylcarnitine in biological fluids. Anal Bioanal Chem 2013; 405:7397-404. [DOI: 10.1007/s00216-013-7193-6] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2013] [Revised: 05/23/2013] [Accepted: 06/28/2013] [Indexed: 12/27/2022]
|
7
|
Magiera S, Baranowska I, Kusa J, Baranowski J. A liquid chromatography and tandem mass spectrometry method for the determination of potential biomarkers of cardiovascular disease. J Chromatogr B Analyt Technol Biomed Life Sci 2013; 919-920:20-9. [PMID: 23411015 DOI: 10.1016/j.jchromb.2012.12.015] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2012] [Revised: 12/10/2012] [Accepted: 12/14/2012] [Indexed: 12/30/2022]
Abstract
A simple, accurate and sensitive liquid chromatography tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantitation of α-ketoglutaric acid (α-KG), L-carnitine (L-CAR) and acetyl-L-carnitine (acetyl-L-CAR) in human urine as potential biomarkers of cardiovascular disease. The separation was performed using an isocratic elution of 0.1% formic acid in water and acetonitrile (97:3, v/v) on an Acclaim 120 C8 column (150 mm × 4.6 mm, 3.0 μm). The flow rate of the mobile phase was 1.2 mL/min and the total assay run time was 3 min. Detection was performed on a triple-quadrupole mass spectrometer in selected reaction monitoring (SRM) mode via an electrospray ionization (ESI) source in positive and negative ion modes. This method covered a linearity range of 0.1-500 ng/mL for L-CAR and acetyl-L-CAR and 1-1000 ng/mL for α-KG with lower limits of quantification (LLOQ) of 0.08 ng/mL for L-CAR, 0.04 ng/mL for acetyl-L-CAR and 0.8 ng/mL for α-KG. The intra-day and inter-day precision and accuracy of the quality control samples exhibited relative standard deviations of less than 5.54% and relative error values from -5.95% to 3.11%. Analyte stability was evaluated under various sample preparation, analysis and storage conditions and varied from -9.89% to -0.47%. A two-step solid-phase extraction (SPE) procedure using silica gel and quaternary amine cartridges was used for urine sample cleanup. The average recoveries for all analyzed compounds were better than 86.64% at three concentrations. The method was successfully applied for the quantitation of α-KG, L-CAR and acetyl-L-CAR in human urine samples.
Collapse
Affiliation(s)
- Sylwia Magiera
- Department of Analytical Chemistry, Silesian University of Technology, 7 M. Strzody Str., 44-100 Gliwice, Poland.
| | | | | | | |
Collapse
|
8
|
Britz-McKibbin P. Expanded newborn screening of inborn errors of metabolism by capillary electrophoresis-electrospray ionization-mass spectrometry (CE-ESI-MS). Methods Mol Biol 2013; 919:43-56. [PMID: 22976089 DOI: 10.1007/978-1-62703-029-8_5] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Expanded newborn screening of inborn errors of metabolism (IEM) based on tandem mass spectrometry technology has emerged as one of the most successful preventative healthcare initiatives for presymptomatic diagnosis and treatment of rare yet treatable genetic diseases. However, confirmatory testing using methods with improved specificity is required in clinical laboratories to improve the positive predictive value for certain classes of IEMs due to their high rates of false positives. Here, we describe recent advances for comprehensive profiling of amino acids and acylcarnitines derived from dried blood spot extracts or plasma using capillary electrophoresis-electrospray ionization-mass spectrometry (CE-ESI-MS) that allows for resolution of major isobaric/isomeric interferences without complicated sample handling. The integration of online sample preconcentration together with desalting in CE-ESI-MS enables the direct analysis of hydrophilic amino acids, surface-active acylcarnitines, as well as labile thiols under a single format when using a simple aqueous buffer electrolyte system.
Collapse
Affiliation(s)
- Philip Britz-McKibbin
- Department of Chemistry and Chemical Biology, McMaster University, Hamilton, ON, Canada.
| |
Collapse
|
9
|
|
10
|
Zhao SS, Zhong X, Tie C, Chen DD. Capillary electrophoresis-mass spectrometry for analysis of complex samples. Proteomics 2012; 12:2991-3012. [DOI: 10.1002/pmic.201200221] [Citation(s) in RCA: 54] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2012] [Revised: 07/10/2012] [Accepted: 07/18/2012] [Indexed: 12/20/2022]
Affiliation(s)
- Shuai Sherry Zhao
- Department of Chemistry; University of British Columbia; Vancouver BC Canada
| | - Xuefei Zhong
- Department of Chemistry; University of British Columbia; Vancouver BC Canada
| | - Cai Tie
- Department of Chemistry; University of British Columbia; Vancouver BC Canada
| | - David D.Y. Chen
- Department of Chemistry; University of British Columbia; Vancouver BC Canada
| |
Collapse
|
11
|
Pormsila W, Morand R, Krähenbühl S, Hauser PC. Capillary electrophoresis with contactless conductivity detection for the determination of carnitine and acylcarnitines in clinical samples. J Chromatogr B Analyt Technol Biomed Life Sci 2011; 879:921-6. [DOI: 10.1016/j.jchromb.2011.02.046] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2010] [Revised: 12/21/2010] [Accepted: 02/25/2011] [Indexed: 02/07/2023]
|
12
|
Tsiafoulis CG, Exarchou V, Tziova PP, Bairaktari E, Gerothanassis IP, Troganis AN. A new method for the determination of free l-carnitine in serum samples based on high field single quantum coherence filtering 1H-NMR spectroscopy. Anal Bioanal Chem 2011; 399:2285-94. [DOI: 10.1007/s00216-010-4600-0] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2010] [Revised: 12/08/2010] [Accepted: 12/12/2010] [Indexed: 11/28/2022]
|
13
|
Ramautar R, Mayboroda OA, Somsen GW, de Jong GJ. CE-MS for metabolomics: Developments and applications in the period 2008-2010. Electrophoresis 2010; 32:52-65. [DOI: 10.1002/elps.201000378] [Citation(s) in RCA: 103] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2010] [Revised: 09/28/2010] [Accepted: 09/28/2010] [Indexed: 12/20/2022]
|
14
|
Desiderio C, Iavarone F, Rossetti DV, Messana I, Castagnola M. Capillary electrophoresis-mass spectrometry for the analysis of amino acids. J Sep Sci 2010; 33:2385-93. [PMID: 20535752 DOI: 10.1002/jssc.201000171] [Citation(s) in RCA: 59] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
In this review, the recent contribution of CE-MS technology to the analysis of amino acids, as well as the advantages of the hyphenation and the technologies involved in the instrumental coupling are reported. Different sections are dedicated to the recent contributions of CE-MS to the analysis of protein amino acids and their post-translational modifications, such as phosphorylation and sulfation. CE-MS analysis of some amino acid derivatives, such as the free methylated-derivatives of arginine is also discussed. A section is specifically devoted to the CE-MS applications in the field of chiral separation of D- and L-amino acid enantiomers.
Collapse
Affiliation(s)
- Claudia Desiderio
- Istituto di Chimica del Riconoscimento Molecolare, Consiglio Nazionale delle Ricerche, c/o Istituto di Biochimica e Biochimica Clinica, Facoltà di Medicina, Università Cattolica, Roma, Italy
| | | | | | | | | |
Collapse
|
15
|
Ramautar R, Toraño JS, Somsen GW, de Jong GJ. Evaluation of CE methods for global metabolic profiling of urine. Electrophoresis 2010; 31:2319-27. [DOI: 10.1002/elps.200900750] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
16
|
Recent advances of capillary electrophoresis in pharmaceutical analysis. Anal Bioanal Chem 2010; 398:29-52. [DOI: 10.1007/s00216-010-3741-5] [Citation(s) in RCA: 105] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2010] [Revised: 04/08/2010] [Accepted: 04/09/2010] [Indexed: 01/16/2023]
|
17
|
|