1
|
Coverdale JPC, Harrington CF, Solovyev N. Review: Advances in the Accuracy and Traceability of Metalloprotein Measurements Using Isotope Dilution Inductively Coupled Plasma Mass Spectrometry. Crit Rev Anal Chem 2023; 54:2259-2276. [PMID: 36637361 DOI: 10.1080/10408347.2022.2162811] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Abstract
Advances in inductively coupled plasma mass spectrometry and the methods used to prepare isotopically enriched standards, allow for the high accuracy measurement of metalloproteins by isotope dilution mass spectrometry. This technique has now reached a level of maturity whereby a step change in the accuracy, precision, and traceability of, in particular, clinical, and biomedical measurements is achievable. Current clinical measurements, which require low limits of detection in the presence of complex sample matrices, use indirect methods based on immunochemistry for the study of human disease. However, this approach suffers from poor traceability, requiring comparisons based on provision of matrix-based reference materials, used as analytical standards. This leads to difficulty when changes in the reference material are required, often resulting in a lack of interlaboratory and temporal comparability in clinical results and reference ranges. In this review, we focus on the most important metalloproteins for clinical studies, to illustrate how the attributes of chromatography coupled to inorganic mass spectrometry can be used for the direct measurement of metalloproteins such as hemoglobin, transferrin, and ceruloplasmin. By using this approach, we hope to demonstrate how isotope dilution analysis can be used as a reference method to improve traceability and underpin clinical, biomedical, and other biological measurements.
Collapse
Affiliation(s)
- James P C Coverdale
- Supra-Regional Assay Service, Trace Element Laboratory, Surrey Research Park, Guildford, United Kingdom
- School of Pharmacy, Institute of Clinical Sciences, College of Medical and Dental Sciences, University of Birmingham, Edgbaston, United Kingdom
| | - Chris F Harrington
- Supra-Regional Assay Service, Trace Element Laboratory, Surrey Research Park, Guildford, United Kingdom
- Royal Surrey NHS Foundation Trust, Guildford, United Kingdom
| | | |
Collapse
|
2
|
Chen J, Wang R, Ma M, Gao L, Zhao B, Xu M. Laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS)-based strategies applied for the analysis of metal-binding protein in biological samples: an update on recent advances. Anal Bioanal Chem 2022; 414:7023-7033. [PMID: 35790569 DOI: 10.1007/s00216-022-04185-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2022] [Revised: 05/21/2022] [Accepted: 06/17/2022] [Indexed: 11/01/2022]
Abstract
New analytical strategies for metal-binding protein facilitate researchers learning about how metals play a significant role in life. Laser ablation-inductively coupled plasma mass spectrometry (LA-ICP-MS) offers many advantages for the metal analysis of biological samples and shows a promising future in protein analysis, but recent advances in LA-ICP-MS-based strategies for identifying metal-binding proteins via endogenous metals remain less updated yet. To present the current status in this field, the main analytical strategies for metal-binding proteins with LA-ICP-MS are reviewed here, including in situ analysis of biospecimens and ex situ analysis with gel electrophoresis. A critical discussion of challenges and future perspectives is also given. Multifarious laser ablation-inductively coupled plasma mass spectrometry (LA-ICP-MS)-based strategies have been developed and applied to investigate the metal-binding proteins in biospecimens in situ or through gel electrophoresis ex situ over the past decades, facilitating researchers disclosing how essential metals are implicated in life or what proteins toxic metals will target.
Collapse
Affiliation(s)
- Jiahao Chen
- School of Environment, Hangzhou Institute for Advanced Study, University of Chinese Academy of Sciences, Hangzhou, 310024, China.,University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Ruixia Wang
- State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China.,University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Minghao Ma
- State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China.,University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Lirong Gao
- School of Environment, Hangzhou Institute for Advanced Study, University of Chinese Academy of Sciences, Hangzhou, 310024, China.,State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China.,University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Bin Zhao
- School of Environment, Hangzhou Institute for Advanced Study, University of Chinese Academy of Sciences, Hangzhou, 310024, China.,State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China.,University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Ming Xu
- School of Environment, Hangzhou Institute for Advanced Study, University of Chinese Academy of Sciences, Hangzhou, 310024, China. .,State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China. .,University of Chinese Academy of Sciences, Beijing, 100049, China.
| |
Collapse
|
3
|
Schaier M, Hermann G, Koellensperger G, Theiner S. Accurate characterization of β-amyloid (Aβ40, Aβ42) standards using species-specific isotope dilution by means of HPLC-ICP-MS/MS. Anal Bioanal Chem 2022; 414:639-648. [PMID: 34355254 PMCID: PMC8748378 DOI: 10.1007/s00216-021-03571-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2021] [Revised: 07/09/2021] [Accepted: 07/20/2021] [Indexed: 11/10/2022]
Abstract
The amyloid β peptide, as one of the main components in senile plaque, represents a defining pathological feature for Alzheimer's disease, and is therefore commonly used as a biomarker for this disease in clinical analysis. However, the selection of suitable standards is limited here, since only a few are commercially available, and these suffer from varying purity. Hence, the accurate characterization of these standards is of great importance. In this study, we developed a method for the traceable quantification of the peptide content using species-specific isotope dilution and ICP-MS/MS detection. It is based on the separation of the sulfur-containing amino acids methionine and cysteine after oxidation and hydrolysis of the peptide. Using a strong anion exchange column, both amino acids could be separated from each other, as well as from their oxidized forms and sulfate. The sulfur content was determined via ICP-MS/MS using oxygen as reaction gas. Species-specific isotope dilution was enabled by using a 34S-labeled yeast hydrolysate, containing methionine sulfone and cysteic acid with different isotopic composition. The peptide contents of Aβ standards (Aβ40,42), as well as myoglobin and lysozyme with different degrees of purity, were determined. For validation purposes, the standard reference material NIST 2389a, which contains the amino acids in a similar concentration, was subjected to the developed sample preparation and analysis method. In addition to accounting for errors during sample preparation, high levels of accuracy and precision could be obtained using this method, making it fit-for-purpose for the characterization of peptide standards.
Collapse
Affiliation(s)
- Martin Schaier
- Institute of Analytical Chemistry, Faculty of Chemistry, University of Vienna, Waehringer Strasse 38, 1090, Vienna, Austria
| | - Gerrit Hermann
- Institute of Analytical Chemistry, Department of Chemistry, University of Natural Resources and Life Sciences, Muthgasse 18, 1190, Vienna, Austria
- ISOtopic solutions e.U., Waehringer Strasse 38, 1090, Vienna, Austria
| | - Gunda Koellensperger
- Institute of Analytical Chemistry, Faculty of Chemistry, University of Vienna, Waehringer Strasse 38, 1090, Vienna, Austria
| | - Sarah Theiner
- Institute of Analytical Chemistry, Faculty of Chemistry, University of Vienna, Waehringer Strasse 38, 1090, Vienna, Austria.
| |
Collapse
|
4
|
Solovyev N, Ala A, Schilsky M, Mills C, Willis K, Harrington CF. Biomedical copper speciation in relation to Wilson’s disease using strong anion exchange chromatography coupled to triple quadrupole inductively coupled plasma mass spectrometry. Anal Chim Acta 2020; 1098:27-36. [DOI: 10.1016/j.aca.2019.11.033] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2019] [Revised: 11/08/2019] [Accepted: 11/13/2019] [Indexed: 12/16/2022]
|
5
|
Lobo L, Pereiro R, Fernández B. Opportunities and challenges of isotopic analysis by laser ablation ICP-MS in biological studies. Trends Analyt Chem 2018. [DOI: 10.1016/j.trac.2018.05.020] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
|
6
|
Bauer OB, Köppen C, Sperling M, Schurek HJ, Ciarimboli G, Karst U. Quantitative Bioimaging of Platinum via Online Isotope Dilution-Laser Ablation-Inductively Coupled Plasma Mass Spectrometry. Anal Chem 2018; 90:7033-7039. [PMID: 29741357 DOI: 10.1021/acs.analchem.8b01429] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Abstract
A new calibration strategy for elemental bioimaging based on online isotope dilution analysis (IDA) and laser ablation-inductively coupled plasma mass spectrometry (LA-ICPMS) was developed and applied for the quantification of platinum in rat kidney tissues. A dry 194Pt spike aerosol was added in a post-cell setup, and the natural 194Pt/195Pt isotope ratio of the sample aerosol from laser ablation was changed accordingly. Spike mass flow determination was carried out based on reversed IDA using a reference standard. Quantitative data obtained by the new approach correlated well with those obtained by external calibration when analyzing parallel tissue slices of rat kidney from cisplatin perfusion studies. The novel quantification approach is traceable to SI units, as IDA is an definitive method. Signal drifts are compensated as the second isotope acts as an internal standard.
Collapse
Affiliation(s)
- Oliver Bolle Bauer
- Westfälische Wilhelms-Universität Münster , Institute of Inorganic and Analytical Chemistry , Corrensstraße 30 , 48149 Münster , Germany
| | - Christina Köppen
- Westfälische Wilhelms-Universität Münster , Institute of Inorganic and Analytical Chemistry , Corrensstraße 30 , 48149 Münster , Germany
| | - Michael Sperling
- Westfälische Wilhelms-Universität Münster , Institute of Inorganic and Analytical Chemistry , Corrensstraße 30 , 48149 Münster , Germany.,European Virtual Institute for Speciation Analysis (EVISA) , Mendelstraße 11 , 48149 Münster , Germany
| | - Hans-Joachim Schurek
- Department of Experimental Nephrology , University Hospital of Münster , Albert-Schweitzer-Campus 1 , 48149 Münster , Germany
| | - Giuliano Ciarimboli
- Department of Experimental Nephrology , University Hospital of Münster , Albert-Schweitzer-Campus 1 , 48149 Münster , Germany
| | - Uwe Karst
- Westfälische Wilhelms-Universität Münster , Institute of Inorganic and Analytical Chemistry , Corrensstraße 30 , 48149 Münster , Germany
| |
Collapse
|
7
|
Montes-Bayón M, Bettmer J. The Use of Stable Isotopic Tracers in Metallomics Studies. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2018; 1055:111-137. [DOI: 10.1007/978-3-319-90143-5_6] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
|
8
|
Susnea I, Weiskirchen R. Trace metal imaging in diagnostic of hepatic metal disease. MASS SPECTROMETRY REVIEWS 2016; 35:666-686. [PMID: 25677057 DOI: 10.1002/mas.21454] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/06/2014] [Revised: 11/25/2014] [Accepted: 12/02/2014] [Indexed: 06/04/2023]
Abstract
The liver is the most central organ and the largest gland of the body that influences and controls a variety of metabolic and catabolic processes. It produces inconceivable many essential proteins, is responsible for the recovery of various food components, degrades toxins, mediates the bile production, and is involved in the excretion of unwanted metabolites. Several of these anabolic or catabolic functions of the liver depend on trace elements. These are either integral part of enzymes, cofactors, or act as chemical catalysts. Therefore, a lack of trace elements can lead to organ failure or systemic illness. Conversely, excessive hepatic trace element deposition resulting from genetic disorders, intoxication, extensive dietary supply, or long-term parenteral nutrition may cause hepatic inflammation, fibrosis, cirrhosis, and even hepatocellular carcinoma. Although specific serum parameters currently allow rough assessment of metal deficit and excess, the precise quantification of hepatic metal content in liver is presently only possible by different titration or staining techniques of biopsy specimens. Recently, novel innovative metal imaging techniques were developed that are on the way to replace these traditional methods. In the present review, we summarize the function of different trace elements in liver health and disease and discuss the present knowledge on how quantitative biometal imaging techniques such as synchrotron X-ray fluorescence microscopy, secondary ion mass spectrometry, and laser ablation inductively coupled plasma mass spectrometry enrich diagnostics in the detection and quantification of hepatic metal disorders. We will further discuss sample preparation, sensitivity, spatial resolution, specificity, quantification strategies, and potential future applications of metal bioimaging in experimental research and clinical daily routine. © 2015 Wiley Periodicals, Inc. Mass Spec Rev 35:666-686, 2016.
Collapse
Affiliation(s)
- Iuliana Susnea
- Central Institute of Engineering, Electronics and Analytics (ZEA-3), Forschungszentrum Jülich, D-52425, Jülich, Germany
| | - Ralf Weiskirchen
- Institute of Molecular Pathobiochemistry, Experimental Gene Therapy and Clinical Chemistry, RWTH University Hospital Aachen, D-52074, Aachen, Germany.
| |
Collapse
|
9
|
A novel quantification strategy of transferrin and albumin in human serum by species-unspecific isotope dilution laser ablation inductively coupled plasma mass spectrometry (ICP-MS). Anal Chim Acta 2015; 884:19-25. [DOI: 10.1016/j.aca.2015.05.009] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2015] [Revised: 05/05/2015] [Accepted: 05/07/2015] [Indexed: 12/11/2022]
|
10
|
Ren Y, Walczyk T. Quantification of ferritin bound iron in human serum using species-specific isotope dilution mass spectrometry. Metallomics 2015; 6:1709-17. [PMID: 25008269 DOI: 10.1039/c4mt00127c] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Ferritin is a hollow sphere protein composed of 24 subunits that can store up to 4500 iron atoms in its inner cavity. It is mainly found in the liver and spleen but also in serum at trace levels. Serum ferritin is considered as the best single indicator in assessing body iron stores except liver or bone marrow biopsy. However, it is confounded by other disease conditions. Ferritin bound iron (FBI) and ferritin saturation have been suggested as more robust biomarkers. The current techniques for FBI determination are limited by low antibody specificity, low instrument sensitivity and possible analyte losses during sample preparation. The need for a highly sensitive and reliable method is widely recognized. Here we describe a novel technique to detect serum FBI using species-specific isotope dilution mass spectrometry (SS-IDMS). [(57)Fe]-ferritin was produced by biosynthesis and in vitro labeling with the (57)Fe spike in the form of [(57)Fe]-citrate after cell lysis and heat treatment. [(57)Fe]-ferritin for sample spiking was further purified by fast liquid protein chromatography. Serum ferritin and added [(57)Fe]-ferritin were separated from other iron species by ultrafiltration followed by isotopic analysis of FBI using negative thermal ionization mass spectrometry. Repeatability of our assay is 8% with an absolute detection limit of 18 ng FBI in the sample. As compared to other speciation techniques, SS-IDMS offers maximum control over sample losses and species conversion during analysis. The described technique may therefore serve as a reference technique for clinical applications of FBI as a new biomarker for assessing body iron status.
Collapse
Affiliation(s)
- Yao Ren
- Department of Chemistry, National University of Singapore, 3 Science Drive 3, Singapore117543.
| | | |
Collapse
|
11
|
Absolute quantification of superoxide dismutase in cytosol and mitochondria of mice hepatic cells exposed to mercury by a novel metallomic approach. Anal Chim Acta 2014; 842:42-50. [PMID: 25127650 DOI: 10.1016/j.aca.2014.07.014] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2014] [Revised: 07/04/2014] [Accepted: 07/13/2014] [Indexed: 11/21/2022]
Abstract
In the last years, the development of new methods for analyzing accurate and precise individual metalloproteins is of increasing importance, since numerous metalloproteins are excellent biomarkers of oxidative stress and diseases. In that way, methods based on the use of post column isotopic dilution analysis (IDA) or enriched protein standards are required to obtain a sufficient degree of accuracy, precision and high limits of detection. This paper reports the identification and absolute quantification of Cu,Zn-superoxide dismutase (Cu,Zn-SOD) in cytosol and mitochondria from mice hepatic cells using a innovative column switching analytical approach. The method consisted of orthogonal chromatographic systems coupled to inductively coupling plasma-mass spectrometry equipped with a octopole reaction systems (ICP-ORS-MS) and UV detectors: size exclusion fractionation (SEC) of the cytosolic and mitochondrial extracts followed by online anion exchange chromatographic (AEC) separation of Cu/Zn containing species. After purification, Cu,Zn-SOD was identified after tryptic digestion by molecular mass spectrometry (MS). The MS/MS spectrum of a doubly charged peptide was used to obtain the sequence of the protein using the MASCOT searching engine. This optimized methodology reduces the time of analysis and avoids the use of sample preconcentration and clean-up procedures, such as cut-off centrifuged filters, solid phase extraction (SPE), precipitation procedures, off-line fractions insolates, etc. In this sense, the method is robust, reliable and fast with typical chromatographic run time less than 20 min. Precision in terms of relative standard deviation (n = 5) is of 3-5% and detection limits is 0.21 ngCug(-1). The application of the methodology to hepatic cells from mice exposed to inorganic mercury reveals decreased levels of Cu,Zn-SOD in cytosolic and mitochondrial extracts, as a consequence of the oxidative stress caused by this toxic metal. Additionally, the quantification of mitochondrial Cu,Zn-SOD in hepatic cells from Mus musculus has been carried out for the first time.
Collapse
|
12
|
Campanella B, Bramanti E. Detection of proteins by hyphenated techniques with endogenous metal tags and metal chemical labelling. Analyst 2014; 139:4124-53. [DOI: 10.1039/c4an00722k] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
The absolute and relative quantitation of proteins plays a fundamental role in modern proteomics, as it is the key to understand still unresolved biological questions in medical and pharmaceutical applications.
Collapse
Affiliation(s)
- Beatrice Campanella
- National Research Council of Italy
- C.N.R
- Istituto di Chimica dei Composti Organo Metallici-ICCOM-UOS Pisa
- 56124 Pisa, Italy
| | - Emilia Bramanti
- National Research Council of Italy
- C.N.R
- Istituto di Chimica dei Composti Organo Metallici-ICCOM-UOS Pisa
- 56124 Pisa, Italy
| |
Collapse
|
13
|
Swart C, Zakel S, Frank C, Fisicaro P, Goenaga-Infante H. Metrological Approach for the Quantification of Metalloproteins (EMRP Project HLT05). EPJ WEB OF CONFERENCES 2014. [DOI: 10.1051/epjconf/20147700007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
14
|
Xu M, Frelon S, Simon O, Lobinski R, Mounicou S. Non-denaturating isoelectric focusing gel electrophoresis for uranium–protein complexes quantitative analysis with LA-ICP MS. Anal Bioanal Chem 2013; 406:1063-72. [DOI: 10.1007/s00216-013-7033-8] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2013] [Revised: 04/24/2013] [Accepted: 04/26/2013] [Indexed: 01/09/2023]
|
15
|
Metrology for metalloproteins—where are we now, where are we heading? Anal Bioanal Chem 2013; 405:5697-723. [DOI: 10.1007/s00216-013-6933-y] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2012] [Revised: 03/18/2013] [Accepted: 03/19/2013] [Indexed: 01/10/2023]
|
16
|
Matsuyama S, Matsunaga A, Sakamoto S, Iida Y, Suzuki Y, Ishizaka Y, Yamauchi K, Ishikawa T, Shimura M. Scanning protein analysis of electrofocusing gels using X-ray fluorescence. Metallomics 2013; 5:492-500. [DOI: 10.1039/c3mt20266f] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
17
|
Sanz-Medel A, Montes-Bayón M, Bettmer J, Luisa Fernández-Sanchez M, Ruiz Encinar J. ICP-MS for absolute quantification of proteins for heteroatom-tagged, targeted proteomics. Trends Analyt Chem 2012. [DOI: 10.1016/j.trac.2012.07.020] [Citation(s) in RCA: 57] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
18
|
Laser ablation ICP-MS for quantitative biomedical applications. Anal Bioanal Chem 2012; 403:2113-25. [DOI: 10.1007/s00216-012-6023-6] [Citation(s) in RCA: 102] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2012] [Revised: 03/27/2012] [Accepted: 04/04/2012] [Indexed: 11/26/2022]
|
19
|
Kutscher DJ, Fricker MB, Hattendorf B, Bettmer J, Günther D. Systematic studies on the determination of Hg-labelled proteins using laser ablation-ICPMS and isotope dilution analysis. Anal Bioanal Chem 2011; 401:2691-8. [DOI: 10.1007/s00216-011-5199-5] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2011] [Revised: 05/26/2011] [Accepted: 06/21/2011] [Indexed: 11/25/2022]
|
20
|
Konz I, Fernández B, Fernández ML, Pereiro R, Sanz-Medel A. Absolute Quantification of Human Serum Transferrin by Species-Specific Isotope Dilution Laser Ablation ICP-MS. Anal Chem 2011; 83:5353-60. [DOI: 10.1021/ac200780b] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Ioana Konz
- Department of Physical and Analytical Chemistry, Faculty of Chemistry, University of Oviedo, Julian Clavería, 8. 33006 Oviedo, Spain
| | - Beatriz Fernández
- Department of Physical and Analytical Chemistry, Faculty of Chemistry, University of Oviedo, Julian Clavería, 8. 33006 Oviedo, Spain
| | - M. Luisa Fernández
- Department of Physical and Analytical Chemistry, Faculty of Chemistry, University of Oviedo, Julian Clavería, 8. 33006 Oviedo, Spain
| | - Rosario Pereiro
- Department of Physical and Analytical Chemistry, Faculty of Chemistry, University of Oviedo, Julian Clavería, 8. 33006 Oviedo, Spain
| | - Alfredo Sanz-Medel
- Department of Physical and Analytical Chemistry, Faculty of Chemistry, University of Oviedo, Julian Clavería, 8. 33006 Oviedo, Spain
| |
Collapse
|
21
|
Sussulini A, Becker JS. Combination of PAGE and LA-ICP-MS as an analytical workflow in metallomics: state of the art, new quantification strategies, advantages and limitations. Metallomics 2011; 3:1271-9. [DOI: 10.1039/c1mt00116g] [Citation(s) in RCA: 49] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|