1
|
Application of nanocomposite polymer hydrogels for ultra-sensitive fluorescence detection of proteins in gel electrophoresis. Trends Analyt Chem 2017. [DOI: 10.1016/j.trac.2017.05.003] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
|
2
|
Dawod M, Arvin NE, Kennedy RT. Recent advances in protein analysis by capillary and microchip electrophoresis. Analyst 2017; 142:1847-1866. [PMID: 28470231 PMCID: PMC5516626 DOI: 10.1039/c7an00198c] [Citation(s) in RCA: 91] [Impact Index Per Article: 11.4] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
This review article describes the significant recent advances in the analysis of proteins by capillary and microchip electrophoresis during the period from mid-2014 to early 2017. This review highlights the progressions, new methodologies, innovative instrumental modifications, and challenges for efficient protein analysis in human specimens, animal tissues, and plant samples. The protein analysis fields covered in this review include analysis of native, reduced, and denatured proteins in addition to Western blotting, protein therapeutics and proteomics.
Collapse
Affiliation(s)
- Mohamed Dawod
- Department of Chemistry, University of Michigan, 930 N. University Ave, Ann Arbor, Michigan 48109, USA.
| | | | | |
Collapse
|
3
|
Weerakoon-Ratnayake KM, Uba FI, Oliver-Calixte NJ, Soper SA. Electrophoretic Separation of Single Particles Using Nanoscale Thermoplastic Columns. Anal Chem 2016; 88:3569-77. [PMID: 26963496 DOI: 10.1021/acs.analchem.5b04065] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Phenomena associated with microscale electrophoresis separations cannot, in many cases, be applied to the nanoscale. Thus, understanding the electrophoretic characteristics associated with the nanoscale will help formulate relevant strategies that can optimize the performance of separations carried out on columns with at least one dimension below 150 nm. Electric double layer (EDL) overlap, diffusion, and adsorption/desorption properties and/or dielectrophoretic effects giving rise to stick/slip motion are some of the processes that can play a role in determining the efficiency of nanoscale electrophoretic separations. We investigated the performance characteristics of electrophoretic separations carried out in nanoslits fabricated in poly(methyl methacrylate), PMMA, devices. Silver nanoparticles (AgNPs) were used as the model system with tracking of their transport via dark field microscopy and localized surface plasmon resonance. AgNPs capped with citrate groups and the negatively charged PMMA walls (induced by O2 plasma modification of the nanoslit walls) enabled separations that were not apparent when these particles were electrophoresed in microscale columns. The separation of AgNPs based on their size without the need for buffer additives using PMMA nanoslit devices is demonstrated herein. Operational parameters such as the electric field strength, nanoslit dimensions, and buffer composition were evaluated as to their effects on the electrophoretic performance, both in terms of efficiency (plate numbers) and resolution. Electrophoretic separations performed at high electric field strengths (>200 V/cm) resulted in higher plate numbers compared to lower fields due to the absence of stick/slip motion at the higher electric field strengths. Indeed, 60 nm AgNPs could be separated from 100 nm particles in free solution using nanoscale electrophoresis with 100 μm long columns.
Collapse
Affiliation(s)
- Kumuditha M Weerakoon-Ratnayake
- Department of Chemistry, Louisiana State University , Baton Rouge, Lousiana 70803, United States.,Department of Biomedical Engineering, University of North Carolina at Chapel Hill , Chapel Hill, North Carolina 27599, United States
| | - Franklin I Uba
- Department of Chemistry, University of North Carolina at Chapel Hill , Chapel Hill, North Carolina 27599, United States
| | - Nyoté J Oliver-Calixte
- Department of Chemistry, Louisiana State University , Baton Rouge, Lousiana 70803, United States.,Department of Biomedical Engineering, University of North Carolina at Chapel Hill , Chapel Hill, North Carolina 27599, United States
| | - Steven A Soper
- Department of Chemistry, Louisiana State University , Baton Rouge, Lousiana 70803, United States.,Department of Biomedical Engineering, University of North Carolina at Chapel Hill , Chapel Hill, North Carolina 27599, United States.,Department of Chemistry, University of North Carolina at Chapel Hill , Chapel Hill, North Carolina 27599, United States.,Center of Biomodular Multiscale Systems for Precision Medicine, University of North Carolina at Chapel Hill , Chapel Hill, North Carolina 27599, United States.,Ulsan National Institute of Science and Technology , Ulsan 44919, South Korea
| |
Collapse
|
4
|
ONeil CE, Jackson JM, Shim SH, Soper SA. Interrogating Surface Functional Group Heterogeneity of Activated Thermoplastics Using Super-Resolution Fluorescence Microscopy. Anal Chem 2016; 88:3686-96. [PMID: 26927303 DOI: 10.1021/acs.analchem.5b04472] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
We present a novel approach for characterizing surfaces utilizing super-resolution fluorescence microscopy with subdiffraction limit spatial resolution. Thermoplastic surfaces were activated by UV/O3 or O2 plasma treatment under various conditions to generate pendant surface-confined carboxylic acids (-COOH). These surface functional groups were then labeled with a photoswitchable dye and interrogated using single-molecule, localization-based, super-resolution fluorescence microscopy to elucidate the surface heterogeneity of these functional groups across the activated surface. Data indicated nonuniform distributions of these functional groups for both COC and PMMA thermoplastics with the degree of heterogeneity being dose dependent. In addition, COC demonstrated relative higher surface density of functional groups compared to PMMA for both UV/O3 and O2 plasma treatment. The spatial distribution of -COOH groups secured from super-resolution imaging were used to simulate nonuniform patterns of electroosmotic flow in thermoplastic nanochannels. Simulations were compared to single-particle tracking of fluorescent nanoparticles within thermoplastic nanoslits to demonstrate the effects of surface functional group heterogeneity on the electrokinetic transport process.
Collapse
Affiliation(s)
| | | | - Sang-Hee Shim
- Department of Biomedical Engineering, School of Life Sciences, Ulsan National Institute of Science and Technology (UNIST) , Ulsan, South Korea
| | - Steven A Soper
- Department of Biomedical Engineering, School of Life Sciences, Ulsan National Institute of Science and Technology (UNIST) , Ulsan, South Korea
| |
Collapse
|
5
|
A review on recent developments for biomolecule separation at analytical scale using microfluidic devices. Anal Chim Acta 2016; 906:7-21. [DOI: 10.1016/j.aca.2015.11.037] [Citation(s) in RCA: 70] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2015] [Revised: 11/24/2015] [Accepted: 11/25/2015] [Indexed: 02/05/2023]
|
6
|
Present state of microchip electrophoresis: state of the art and routine applications. J Chromatogr A 2014; 1382:66-85. [PMID: 25529267 DOI: 10.1016/j.chroma.2014.11.034] [Citation(s) in RCA: 130] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2014] [Revised: 11/07/2014] [Accepted: 11/12/2014] [Indexed: 12/20/2022]
Abstract
Microchip electrophoresis (MCE) was one of the earliest applications of the micro-total analysis system (μ-TAS) concept, whose aim is to reduce analysis time and reagent and sample consumption while increasing throughput and portability by miniaturizing analytical laboratory procedures onto a microfluidic chip. More than two decades on, electrophoresis remains the most common separation technique used in microfluidic applications. MCE-based instruments have had some commercial success and have found application in many disciplines. This review will consider the present state of MCE including recent advances in technology and both novel and routine applications in the laboratory. We will also attempt to assess the impact of MCE in the scientific community and its prospects for the future.
Collapse
|
7
|
Battle KN, Uba FI, Soper SA. Microfluidics for the analysis of membrane proteins: How do we get there? Electrophoresis 2014; 35:2253-66. [DOI: 10.1002/elps.201300625] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2013] [Revised: 02/16/2014] [Accepted: 02/17/2014] [Indexed: 01/22/2023]
Affiliation(s)
- Katrina N. Battle
- Department of Chemistry; Louisiana State University; Baton Rouge LA USA
| | - Franklin I. Uba
- Department of Chemistry; University of North Carolina; Chapel Hill NC USA
| | - Steven A. Soper
- Department of Chemistry; Louisiana State University; Baton Rouge LA USA
- Department of Chemistry; University of North Carolina; Chapel Hill NC USA
- Department of Biomedical Engineering; University of North Carolina; Chapel Hill NC USA
- BioFluidica, LLC, c/o Carolina Kick-Start; Chapel Hill NC USA
- School of Nano-Bioscience and Chemical Engineering; Ulsan National Institute of Science and Technology; Ulsan Korea
| |
Collapse
|
8
|
Wang S, Njoroge SK, Battle K, Zhang C, Hollins BC, Soper SA, Feng J. Two-dimensional nitrosylated protein fingerprinting by using poly (methyl methacrylate) microchips. LAB ON A CHIP 2012; 12:3362-3369. [PMID: 22766561 DOI: 10.1039/c2lc40132k] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
S-nitrosylation (also referred to as nitrosation), a reversible post translational modification (PTM) of cysteine, plays an important role in cellular functions and cell signalling pathways. Nitrosylated proteins are considered as biomarkers of aging and Alzheimer's disease (AD). Microfluidics has been widely used for development of novel tools for separation of protein mixtures. Here we demonstrate two-dimensional micro-electrophoresis (2D μ-CE) separations of nitrosylated proteins from the human colon epithelial adenocarcinoma cells (HT-29) and AD transgenic mice brain tissues. Sodium dodecyl sulphate micro-capillary gel electrophoresis (SDS μ-CGE) and microemulsion electrokinetic chromatography (MEEKC) were used for the first and second dimensional separations, respectively. The effective separation lengths for both dimensions were 10 mm, and electrokinetic injection was used with field strength at 200 V cm(-1). After 80 s separation in the first CGE dimension, fractions were successfully transferred to a second MEEKC dimension for a short 10 s separation. We first demonstrate this 2D μ-CE separation by resolving five standard proteins with molecular weight (MW) ranging from 20 to 64 kDa. We also present a high peak capacity 3D landscape image of nitrosylated proteins from HT-29 cells before and following menadione (MQ) treatment to induce oxidative stress. Additionally, to illustrate the potential of the 2D μ-CE separation method for rapid profiling of oxidative stress-induced biomarkers implicated in AD disease, the nitrosylated protein fingerprints from 11-month-old AD transgenic mice brain and their age matched controls were also generated. To our knowledge, this is the first report on 2D profiling of nitrosylated proteins in biological samples on a microchip. The characteristics of this biomarker profiling will potentially serve as the screening for early detection of AD.
Collapse
Affiliation(s)
- Siyang Wang
- Department of Biomedical Engineering, Louisiana Tech University, Ruston, USA
| | | | | | | | | | | | | |
Collapse
|
9
|
High-throughput analysis of therapeutic and diagnostic monoclonal antibodies by multicapillary SDS gel electrophoresis in conjunction with covalent fluorescent labeling. Anal Bioanal Chem 2012; 404:1485-94. [DOI: 10.1007/s00216-012-6213-2] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2012] [Revised: 06/15/2012] [Accepted: 06/18/2012] [Indexed: 12/13/2022]
|
10
|
Zhu Z, Lu JJ, Liu S. Protein separation by capillary gel electrophoresis: a review. Anal Chim Acta 2012; 709:21-31. [PMID: 22122927 PMCID: PMC3227876 DOI: 10.1016/j.aca.2011.10.022] [Citation(s) in RCA: 132] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2011] [Revised: 10/02/2011] [Accepted: 10/07/2011] [Indexed: 12/13/2022]
Abstract
Capillary gel electrophoresis (CGE) has been used for protein separation for more than two decades. Due to the technology advancement, current CGE methods are becoming more and more robust and reliable for protein analysis, and some of the methods have been routinely used for the analysis of protein-based pharmaceuticals and quality controls. In light of this progress, we survey 147 papers related to CGE separations of proteins and present an overview of this technology. We first introduce briefly the early development of CGE. We then review the methodology, in which we specifically describe the matrices, coatings, and detection strategies used in CGE. CGE using microfabricated channels and incorporation of CGE with two-dimensional protein separations are also discussed in this section. We finally present a few representative applications of CGE for separating proteins in real-world samples.
Collapse
Affiliation(s)
- Zaifang Zhu
- Department of Chemistry and Biochemistry, University of Oklahoma, Norman, OK 73019
| | - Joann J. Lu
- Department of Chemistry and Biochemistry, University of Oklahoma, Norman, OK 73019
| | - Shaorong Liu
- Department of Chemistry and Biochemistry, University of Oklahoma, Norman, OK 73019
| |
Collapse
|
11
|
Intact protein analysis in the biopharmaceutical field. J Pharm Biomed Anal 2011; 55:810-22. [DOI: 10.1016/j.jpba.2011.01.031] [Citation(s) in RCA: 132] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2010] [Revised: 01/18/2011] [Accepted: 01/21/2011] [Indexed: 01/09/2023]
|
12
|
Osiri JK, Shadpour H, Witek MA, Soper SA. Integrated multifunctional microfluidics for automated proteome analyses. Top Curr Chem (Cham) 2011; 304:261-94. [PMID: 21678138 DOI: 10.1007/128_2011_152] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Abstract
Proteomics is a challenging field for realizing totally integrated microfluidic systems for complete proteome processing due to several considerations, including the sheer number of different protein types that exist within most proteomes, the large dynamic range associated with these various protein types, and the diverse chemical nature of the proteins comprising a typical proteome. For example, the human proteome is estimated to have >10(6) different components with a dynamic range of >10(10). The typical processing pipeline for proteomics involves the following steps: (1) selection and/or extraction of the particular proteins to be analyzed; (2) multidimensional separation; (3) proteolytic digestion of the protein sample; and (4) mass spectral identification of either intact proteins (top-down proteomics) or peptide fragments generated from proteolytic digestions (bottom-up proteomics). Although a number of intriguing microfluidic devices have been designed, fabricated and evaluated for carrying out the individual processing steps listed above, work toward building fully integrated microfluidic systems for protein analysis has yet to be realized. In this chapter, information will be provided on the nature of proteomic analysis in terms of the challenges associated with the sample type and the microfluidic devices that have been tested to carry out individual processing steps. These include devices such as those for multidimensional electrophoretic separations, solid-phase enzymatic digestions, and solid-phase extractions, all of which have used microfluidics as the functional platform for their implementation. This will be followed by an in-depth review of microfluidic systems, which are defined as units possessing two or more devices assembled into autonomous systems for proteome processing. In addition, information will be provided on the challenges involved in integrating processing steps into a functional system and the approaches adopted for device integration. In this chapter, we will focus exclusively on the front-end processing microfluidic devices and systems for proteome processing, and not on the interface technology of these platforms to mass spectrometry due to the extensive reviews that already exist on these types of interfaces.
Collapse
Affiliation(s)
- John K Osiri
- Department of Chemistry, Louisiana State University, Baton Rouge, LA 70817, USA
| | | | | | | |
Collapse
|
13
|
Abstract
Profiling of protein biomarkers is powerful for the analysis of complex proteomes altered during the progression of diseases. Lab-on-a-chip technologies can potentially provide the throughput and efficiency required for point-of-care and clinical applications. While initial studies utilized 1D microchip separation techniques, researchers have recently developed novel 2D microchip separation platforms with the ability to profile thousands of proteins more effectively. Despite advancements in lab-on-a-chip technologies, very few reports have demonstrated a point-of-care microchip-based profiling of proteins. In this review, recent progress in 1D and 2D microchip profiling of protein mixtures of a biological sample with potential point-of-care applications are discussed. A selection of recent microchip immunoassay-based techniques is also highlighted.
Collapse
|