1
|
Gopika MG, Gopidas S, Jayan GS, Arathy PS, Saraswathyamma B. Unveiling thiol biomarkers: Glutathione and cysteamine. Clin Chim Acta 2024; 563:119915. [PMID: 39134217 DOI: 10.1016/j.cca.2024.119915] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2024] [Revised: 08/08/2024] [Accepted: 08/09/2024] [Indexed: 08/16/2024]
Abstract
The physiological and clinical importance of Glutathione and Cysteamine is emphasized by their participation in a range of conditions, such as diabetes, cancer, renal failure, Parkinson's disease, and hypothyroidism. This necessitates the requirement for accessible, expedited, and cost-efficient testing that can facilitate clinical diagnosis and treatment options. This article examines numerous techniques used to detect both glutathione and cysteamine. The discussed methods include electroanalytical techniques such as voltammetry and amperometry, which are examined for their sensitivity and ability to provide real-time analysis. Furthermore, this study investigates the accuracy of gas chromatography-mass spectrometry (GC-MS) and high-performance liquid chromatography (HPLC) in measuring the concentrations of glutathione and cysteamine. Additionally, the potential of new nanotechnology-based methods, such as plasmonic nanoparticles and quantum dots, to improve the sensitivity of detecting glutathione and cysteamine is emphasized.
Collapse
Affiliation(s)
- M G Gopika
- Department of Chemistry, Amrita Vishwa Vidyapeetham, Amritapuri Campus, Clappana P O, Kollam, Kerala 690525, India
| | - Surya Gopidas
- Department of Chemistry, Amrita Vishwa Vidyapeetham, Amritapuri Campus, Clappana P O, Kollam, Kerala 690525, India
| | - Gokul S Jayan
- Department of Chemistry, Amrita Vishwa Vidyapeetham, Amritapuri Campus, Clappana P O, Kollam, Kerala 690525, India
| | - P S Arathy
- Department of Chemistry, Amrita Vishwa Vidyapeetham, Amritapuri Campus, Clappana P O, Kollam, Kerala 690525, India
| | - Beena Saraswathyamma
- Department of Chemistry, Amrita Vishwa Vidyapeetham, Amritapuri Campus, Clappana P O, Kollam, Kerala 690525, India.
| |
Collapse
|
2
|
Bagherpour S, Pérez-García L. Recent advances on nanomaterial-based glutathione sensors. J Mater Chem B 2024; 12:8285-8309. [PMID: 39081041 DOI: 10.1039/d4tb01114g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/29/2024]
Abstract
Glutathione (GSH) is one of the most common thiol-containing molecules discovered in biological systems, and it plays an important role in many cellular functions, where changes in physiological glutathione levels contribute to the progress of a variety of diseases. Molecular imaging employing fluorescent probes is thought to be a sensitive technique for online fluorescence detection of GSH. Although various molecular probes for (intracellular) GSH sensing have been reported, some aspects remain unanswered, such as quantitative intracellular analysis, dynamic monitoring, and compatibility with biological environment. Some of these drawbacks can be overcome by sensors based on nanostructured materials, that have attracted considerable attention owing to their exceptional properties, including a large surface area, heightened electro-catalytic activity, and robust mechanical resilience, for which they have become integral components in the development of highly sensitive chemo- and biosensors. Additionally, engineered nanomaterials have demonstrated significant promise in enhancing the precision of disease diagnosis and refining treatment specificity. The aim of this review is to investigate recent advancements in fabricated nanomaterials tailored for detecting GSH. Specifically, it examines various material categories, encompassing carbon, polymeric, quantum dots (QDs), covalent organic frameworks (COFs), metal-organic frameworks (MOFs), metal-based, and silicon-based nanomaterials, applied in the fabrication of chemo- and biosensors. The fabrication of nano-biosensors, mechanisms, and methodologies employed for GSH detection utilizing these fabricated nanomaterials will also be elucidated. Remarkably, there is a noticeable absence of existing reviews specifically dedicated to the nanomaterials for GSH detection since they are not comprehensive in the case of nano-fabrication, mechanisms and methodologies of detection, as well as applications in various biological environments. This research gap presents an opportune moment to thoroughly assess the potential of nanomaterial-based approaches in advancing GSH detection methodologies.
Collapse
Affiliation(s)
- Saman Bagherpour
- Departament de Farmacologia, Toxicologia i Química Terapèutica, Universitat de Barcelona, Av. Joan XXIII 27-31, Barcelona, 08028, Spain.
- Institut de Nanociència i Nanotecnologia IN2UB, Universitat de Barcelona, Barcelona, 08028, Spain
| | - Lluïsa Pérez-García
- Departament de Farmacologia, Toxicologia i Química Terapèutica, Universitat de Barcelona, Av. Joan XXIII 27-31, Barcelona, 08028, Spain.
- Institut de Nanociència i Nanotecnologia IN2UB, Universitat de Barcelona, Barcelona, 08028, Spain
| |
Collapse
|
3
|
Xu C, Li G, Gan L, Yuan B. In Situ Electrochemical Formation of Oxo-Functionalized Graphene on Glassy Carbon Electrode with Chemical Fouling Recovery and Antibiofouling Properties for Electrochemical Sensing of Reduced Glutathione. Antioxidants (Basel) 2022; 12:antiox12010008. [PMID: 36670870 PMCID: PMC9854563 DOI: 10.3390/antiox12010008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2022] [Revised: 12/16/2022] [Accepted: 12/19/2022] [Indexed: 12/24/2022] Open
Abstract
Electrochemical detection can be used to achieve intracellular or in vivo analysis of reduced glutathione (GSH) in tissues such as brain by using a microelectrode, which can help to better understand the complex biochemical processes of this molecule in the human body. The main challenges associated with electrochemical GSH detection are the chemical fouling of electrodes, caused by the oxidation product of GSSG, and biofouling due to the non-specific absorption of biological macromolecules. Oxo-functionalized graphene was generated in situ on the surface of a glassy carbon electrode using a green electrochemical method without using any other modifiers or materials in a mild water solution. The fabricated oxo-functionalized graphene interface was characterized by Raman spectroscopy, X-ray photoelectron spectroscopy, electrochemistry, electrochemical impedance spectroscopy, and contact angle measurements. The interface showed high electrocatalytic activity towards the oxidation of GSH, and a simple and efficient GSH sensor was developed. Interestingly, the electrode is reusable and could be recovered from the chemical fouling via electrochemical oxidation and reduction treatment. The electrode also exhibited good antibiofouling properties. The presented method could be a promising method used to treat carbon materials, especially carbon-based microelectrodes for electrochemical monitoring of intracellular glutathione or in vivo analysis.
Collapse
|
4
|
Romano MP, Lionetto MG, Mangone A, De Bartolomeo AR, Giordano ME, Contini D, Guascito MR. Development and characterization of a gold nanoparticles glassy carbon modified electrode for dithiotreitol (DTT) detection suitable to be applied for determination of atmospheric particulate oxidative potential. Anal Chim Acta 2022; 1206:339556. [DOI: 10.1016/j.aca.2022.339556] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2021] [Revised: 01/20/2022] [Accepted: 01/24/2022] [Indexed: 11/01/2022]
|
5
|
Kaimal R, Senthilkumar P, Aljafari B, Anandan S. A nanosecond pulsed laser-ablated MWCNT-Au heterostructure: an innovative ultra-sensitive electrochemical sensing prototype for the identification of glutathione. Analyst 2022; 147:3894-3907. [DOI: 10.1039/d2an00967f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Here, a scheme that aptly describes the reduction of gold nanoparticles’ crystalline size on the surface of MWCNTs in an aqueous phase to generate a LAMWCNT-Au heterostructure, employing an Nd:YAG laser (energy = 505 mJ and λ = 1064 nm) is developed.
Collapse
Affiliation(s)
- Reshma Kaimal
- Nanomaterials & Solar Energy Conversion Lab, Department of Chemistry, National Institute of Technology, Tiruchirappalli-620015, India
| | - Periyathambi Senthilkumar
- Department of Veterinary Pharmacology and Toxicology, Veterinary College, and Research Institute, TANUVAS, Tirunelveli 627358, India
| | - Belqasem Aljafari
- Department of Electrical Engineering, College of Engineering, Najran University, Najran 11001, Saudi Arabia
| | - Sambandam Anandan
- Nanomaterials & Solar Energy Conversion Lab, Department of Chemistry, National Institute of Technology, Tiruchirappalli-620015, India
| |
Collapse
|
6
|
Wang H, Hua H, Tang H, Li Y. Dual-signaling amplification strategy for glutathione sensing by using single gold nanoelectrodes. Anal Chim Acta 2021; 1166:338579. [PMID: 34022990 DOI: 10.1016/j.aca.2021.338579] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2021] [Revised: 04/05/2021] [Accepted: 04/23/2021] [Indexed: 01/18/2023]
Abstract
A new nanosensor for glutathione (GSH) detection by use of single nanoelectrodes has been developed through a dual-signaling ratiometric amplification strategy. Ag nanoparticles (Ag NPs) metalized DNA1 was modified on an Au nanoelectrode surface. Due to the strong affinity between Ag NP and GSH, Ag NPs could be removed by the addition of GSH. The remaining metalized DNA1 could hardly form a double strand, while the de-metalized DNA1 could hybrid with DNA2 and DNA3 to form a complex structure to adsorb methylene blue (MB), and then the electrochemical signal of differential pulse voltammetry (DPV) from MB oxidation could be observed. With the addition of GSH, the peak current of MB oxidation at about -0.27 V (IMB) increases, while the signal of Ag oxidation at about 0.1 V (IAg) decreases. It was found that there had a linear relationship between the ratio of dual-signal (IMB/IAg) and the GSH concentrations, which could be used to detect GSH. The ratiometric nanosensor is label-free, easy to operate, and can eliminate inherent system errors. Considering the advantages of nanoelectrodes, such as low IR drop, fast response, and small overall dimension, this developed nanosensor can be used for GSH detection living systems (e.g., cell lysate).
Collapse
Affiliation(s)
- Hao Wang
- Anhui Key Laboratory of Chemo/Biosensing, College of Chemistry and Materials Science, Anhui Normal University, Wuhu, 241000, PR China
| | - Hongmei Hua
- Anhui Key Laboratory of Chemo/Biosensing, College of Chemistry and Materials Science, Anhui Normal University, Wuhu, 241000, PR China
| | - Haoran Tang
- Anhui Key Laboratory of Chemo/Biosensing, College of Chemistry and Materials Science, Anhui Normal University, Wuhu, 241000, PR China
| | - Yongxin Li
- Anhui Key Laboratory of Chemo/Biosensing, College of Chemistry and Materials Science, Anhui Normal University, Wuhu, 241000, PR China.
| |
Collapse
|
7
|
Azab SM, Elhakim HK, Fekry AM. The strategy of nanoparticles and the flavone chrysin to quantify miRNA-let 7a in zepto-molar level: Its application as tumor marker. J Mol Struct 2019. [DOI: 10.1016/j.molstruc.2019.06.111] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
8
|
Fekry AM, Mohamed GG, Abou Attia FM, Ibrahim NS, Azab SM. A nanoparticle modified carbon paste sensor for electrochemical determination of the antidepressant agent vilazodone. J Electroanal Chem (Lausanne) 2019. [DOI: 10.1016/j.jelechem.2019.113305] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
9
|
Azab SM. A comprehensive structural comparison between cellulose and starch polymers functionalized cobalt nanoparticles sensors for the nanomolar detection of paracetamol. J Electroanal Chem (Lausanne) 2019. [DOI: 10.1016/j.jelechem.2019.04.011] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
10
|
Hanko M, Švorc Ľ, Planková A, Mikuš P. Overview and recent advances in electrochemical sensing of glutathione - A review. Anal Chim Acta 2019; 1062:1-27. [PMID: 30947984 DOI: 10.1016/j.aca.2019.02.052] [Citation(s) in RCA: 62] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2018] [Revised: 02/20/2019] [Accepted: 02/22/2019] [Indexed: 12/13/2022]
Abstract
The present paper is aimed at providing an overview of the recent advances in the electrochemical sensing of glutathione (GSH), an important electrochemically and biologically active molecule, for the period 2012-2018. Herein, the analytical performances of newly developed electrochemical methods, procedures and protocols for GSH sensing are comprehensively and critically discussed with respect to the type of method, electrodes used (new electrode modifications, advanced materials and formats), sample matrices, and basic validation parameters obtained (limit of detection, linear dynamic range, precision, selectivity/evaluation of interferences). This paper considers electrochemical methods used alone as well as the hyphenated methods with electrochemical detection (ECD), such as HPLC-ECD or CE-ECD. The practical applicability of the platforms developed for GSH detection and quantification is mostly focused on pharmaceutical and biomedical analysis. The most significant electrochemical approaches for GSH detection in multicomponent analyte samples and multicomponent matrices and for real-time in vivo GSH analysis are highlighted. The great variability in the electrochemical techniques, electrode approaches, and obtainable performance parameters, discussed in this review, brought new insights not only on current GSH and glutathione disulfide (GSSG) determinations, but, along with this, on the advances in electrochemical analysis from a more general point of view.
Collapse
Affiliation(s)
- Michal Hanko
- Comenius University in Bratislava, Faculty of Pharmacy, Department of Pharmaceutical Analysis and Nuclear Pharmacy, Odbojárov 10, SK-832 32, Bratislava, Slovak Republic
| | - Ľubomír Švorc
- Slovak University of Technology in Bratislava, Faculty of Chemical and Food Technology, Institute of Analytical Chemistry, Radlinského 9, SK-812 37, Bratislava, Slovak Republic
| | - Alexandra Planková
- Comenius University in Bratislava, Faculty of Pharmacy, Department of Pharmaceutical Analysis and Nuclear Pharmacy, Odbojárov 10, SK-832 32, Bratislava, Slovak Republic
| | - Peter Mikuš
- Comenius University in Bratislava, Faculty of Pharmacy, Department of Pharmaceutical Analysis and Nuclear Pharmacy, Odbojárov 10, SK-832 32, Bratislava, Slovak Republic; Comenius University in Bratislava, Faculty of Pharmacy, Toxicological and Antidoping Center, Odbojárov 10, SK-832 32, Bratislava, Slovak Republic.
| |
Collapse
|
11
|
Azab SM, Fekry AM. Role of Green Chemistry in Antipsychotics' Electrochemical Investigations Using a Nontoxic Modified Sensor in McIlvaine Buffer Solution. ACS OMEGA 2019; 4:25-30. [PMID: 31459308 PMCID: PMC6648889 DOI: 10.1021/acsomega.8b01972] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/10/2018] [Accepted: 12/11/2018] [Indexed: 05/03/2023]
Abstract
A new low-cost green electrochemical sensor based on nontoxic polyethylene glycol (PEG) and silver nanoparticles was used to improve the sensitivity of the carbon paste electrode for the investigation of olanzapine (OLZ) in dosage arrangements and in the existence of its coadministered drug fluoxetine and in the drug formulation. Scanning electron microscopy measurements were carried out to emphasize the morphology of the electrode surface. Cyclic voltammetry and differential pulse voltammetry were used to explore the diffusion and linearity behaviors of OLZ. Impedance spectroscopy measurements were determined to investigate the ac behavior of OLZ and then an ideal electrical circuit was modeled. A linear calibration was obtained from 1.0 × 10-8 to 1.25 × 10-4 M. The limit of detection was 1.5 × 10-9 M, whereas the limit of quantification was 5 × 10-9 M. The way has been wholly authenticated concerning linearity, precision, accuracy, reproducibility, sensitivity, and selectivity.
Collapse
Affiliation(s)
- Shereen M. Azab
- Pharmaceutical Chemistry
Department, National Organization for Drug
Control and Research, 6 Abu Hazem Street, Pyramids Avenue, P.O. Box 29, Giza 12613, Egypt
- E-mail: (S.M.A.)
| | - Amany M. Fekry
- Chemistry Department, Faculty of Science, Cairo University, Giza 12613, Egypt
- E-mail: (A.M.F.)
| |
Collapse
|
12
|
Azab SM, Shehata M, Fekry AM. A novel electrochemical analysis of the legal psychoactive drug caffeine using a zeolite/MWCNT modified carbon paste sensor. NEW J CHEM 2019. [DOI: 10.1039/c9nj04070f] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Caffeine (Caf) is a natural central nervous system stimulant categorized by the US Food and Drug Administration as a safe drug and its maximal amount in soft drinks has been approximately determined to be lower than 200 mg L−1.
Collapse
Affiliation(s)
- Shereen M. Azab
- Pharmaceutical Chemistry Dept
- National Organization for Drug Control and Research [NODCAR]
- 6 Abu Hazem Street
- Pyramids Ave, 29
- Giza
| | - M. Shehata
- Chemistry Department
- Faculty of Science
- Cairo University
- Giza 12613
- Egypt
| | - Amany M. Fekry
- Chemistry Department
- Faculty of Science
- Cairo University
- Giza 12613
- Egypt
| |
Collapse
|
13
|
Yuan B, Xu C, Zhang R, Lv D, Li S, Zhang D, Liu L, Fernandez C. Glassy carbon electrode modified with 7,7,8,8-tetracyanoquinodimethane and graphene oxide triggered a synergistic effect: Low-potential amperometric detection of reduced glutathione. Biosens Bioelectron 2017; 96:1-7. [PMID: 28448855 DOI: 10.1016/j.bios.2017.04.026] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2017] [Revised: 03/30/2017] [Accepted: 04/20/2017] [Indexed: 10/19/2022]
Abstract
A sensitive electrochemical sensor based on the synergistic effect of 7,7,8,8-tetracyanoquinodimethane (TCNQ) and graphene oxide (GO) for low-potential amperometric detection of reduced glutathione (GSH) in pH 7.2 phosphate buffer solution (PBS) has been reported. This is the first time that the combination of GO and TCNQ have been successfully employed to construct an electrochemical sensor for the detection of glutathione. The surface of the glassy carbon electrode (GCE) was modified by a drop casting using TCNQ and GO. Cyclic voltammetric measurements showed that TCNQ and GO triggered a synergistic effect and exhibited an unexpected electrocatalytic activity towards GSH oxidation, compared to GCE modified with only GO, TCNQ or TCNQ/electrochemically reduced GO. Three oxidation waves for GSH were found at -0.05, 0.1 and 0.5V, respectively. Amperometric techniques were employed to detect GSH sensitively using a GCE modified with TCNQ/GO at -0.05V. The electrochemical sensor showed a wide linear range from 0.25 to 124.3μM and 124.3μM to 1.67mM with a limit of detection of 0.15μM. The electroanalytical sensor was successfully applied towards the detection of GSH in an eye drop solution.
Collapse
Affiliation(s)
- Baiqing Yuan
- Henan Province Key Laboratory of New Optoelectronic Functional Materials, College of Chemistry and Chemical Engineering, Anyang Normal University, Anyang 455000, Henan, China.
| | - Chunying Xu
- Henan Province Key Laboratory of New Optoelectronic Functional Materials, College of Chemistry and Chemical Engineering, Anyang Normal University, Anyang 455000, Henan, China
| | - Renchun Zhang
- Henan Province Key Laboratory of New Optoelectronic Functional Materials, College of Chemistry and Chemical Engineering, Anyang Normal University, Anyang 455000, Henan, China
| | - Donghui Lv
- Henan Province Key Laboratory of New Optoelectronic Functional Materials, College of Chemistry and Chemical Engineering, Anyang Normal University, Anyang 455000, Henan, China
| | - Sujuan Li
- Henan Province Key Laboratory of New Optoelectronic Functional Materials, College of Chemistry and Chemical Engineering, Anyang Normal University, Anyang 455000, Henan, China
| | - Daojun Zhang
- Henan Province Key Laboratory of New Optoelectronic Functional Materials, College of Chemistry and Chemical Engineering, Anyang Normal University, Anyang 455000, Henan, China
| | - Lin Liu
- Henan Province Key Laboratory of New Optoelectronic Functional Materials, College of Chemistry and Chemical Engineering, Anyang Normal University, Anyang 455000, Henan, China
| | - Carlos Fernandez
- School of Pharmacy and Life Sciences, Robert Gordon University, Garthdee Road, Aberdeen AB10 7GJ, United Kingdom.
| |
Collapse
|
14
|
Electrochemistry of glucose at gold nanoparticles modified graphite/SrPdO3 electrode – Towards a novel non-enzymatic glucose sensor. J Electroanal Chem (Lausanne) 2015. [DOI: 10.1016/j.jelechem.2015.04.033] [Citation(s) in RCA: 59] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
15
|
Potentiometric stripping analysis of arsenic using a graphene paste electrode modified with a thiacrown ether and gold nanoparticles. Mikrochim Acta 2015. [DOI: 10.1007/s00604-015-1470-3] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
16
|
Madasamy T, Santschi C, Martin OJF. A miniaturized electrochemical assay for homocysteine using screen-printed electrodes with cytochrome c anchored gold nanoparticles. Analyst 2015. [DOI: 10.1039/c5an00752f] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Electrochemical point-of-care analysis of homocysteine in a drop of the blood plasma samples.
Collapse
Affiliation(s)
- Thangamuthu Madasamy
- Nanophotonics and Metrology Laboratory (NAM)
- Swiss Federal Institute of Technology Lausanne (EPFL)
- CH-1015 Lausanne
- Switzerland
| | - Christian Santschi
- Nanophotonics and Metrology Laboratory (NAM)
- Swiss Federal Institute of Technology Lausanne (EPFL)
- CH-1015 Lausanne
- Switzerland
| | - Olivier J. F. Martin
- Nanophotonics and Metrology Laboratory (NAM)
- Swiss Federal Institute of Technology Lausanne (EPFL)
- CH-1015 Lausanne
- Switzerland
| |
Collapse
|
17
|
Wang T, Su W, Xiao Z, Hao S, Li Y, Hu J. Highly sensitive determination of reduced glutathione based on a cobalt nanoparticle implanted-modified indium tin oxide electrode. Analyst 2015; 140:5176-83. [DOI: 10.1039/c5an00631g] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Cobalt nanoparticle modified indium tin oxide (CoNP/ITO) electrodes fabricated by ion implantation were applied for the detection of reduced glutathione (GSH).
Collapse
Affiliation(s)
- Tong Wang
- College of Chemistry
- Beijing Normal University
- Beijing 100875
- PR China
| | - Wen Su
- College of Chemistry
- Beijing Normal University
- Beijing 100875
- PR China
| | - Zhengjun Xiao
- College of Chemistry
- Beijing Normal University
- Beijing 100875
- PR China
| | - Shuang Hao
- College of Chemistry
- Beijing Normal University
- Beijing 100875
- PR China
| | - Yuanchun Li
- College of Chemistry
- Beijing Normal University
- Beijing 100875
- PR China
| | - Jingbo Hu
- College of Chemistry
- Beijing Normal University
- Beijing 100875
- PR China
- Key Laboratory of Beam Technology and Material Modification of Ministry of Education
| |
Collapse
|
18
|
Ganguly M, Mondal C, Jana J, Pal A, Pal T. Photoproduced fluorescent Au(I)@(Ag2/Ag3)-thiolate giant cluster: an intriguing sensing platform for DMSO and Pb(II). LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2014; 30:348-357. [PMID: 24359547 DOI: 10.1021/la403848z] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Synergistic evolution of fluorescent Au(I)@(Ag2/Ag3)-thiolate core-shell particles has been made possible under the Sun in presence of the respective precursor coinage metal compounds and glutathione (GSH). The green chemically synthesized fluorescent clusters are giant (∼600 nm) in size and robust. Among all the common water miscible solvents, exclusively DMSO exhibits selective fluorescence quenching (Turn Off) because of the removal of GSH from the giant cluster. Again, only Pb(II) ion brings back the lost fluorescence (Turn On) leaving aside all other metal ions. This happens owing to the strong affinity of the sulfur donor of DMSO for Pb(II). Thus, employing the aqueous solution containing the giant cluster, we can detect DMSO contamination in water bodies at trace level. Besides, a selective sensing platform has emerged out for Pb(II) ion with a detection limit of 14 × 10(-8) M. Pb(II) induced fluorescence recovery is again vanished by I(-) implying a promising route to sense I(-) ion.
Collapse
Affiliation(s)
- Mainak Ganguly
- Department of Chemistry, Indian Institute of Technology , Kharagpur-721302, West Bengal, India
| | | | | | | | | |
Collapse
|
19
|
Lotfi Zadeh Zhad HR, Lai RY. A Hg(ii)-mediated “signal-on” electrochemical glutathione sensor. Chem Commun (Camb) 2014; 50:8385-7. [DOI: 10.1039/c4cc03329a] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|