1
|
Luo RY, Wong C, Xia JQ, Glader BE, Shi RZ, Zehnder JL. Neutral-Coating Capillary Electrophoresis Coupled with High-Resolution Mass Spectrometry for Top-Down Identification of Hemoglobin Variants. Clin Chem 2023; 69:56-67. [PMID: 36308334 DOI: 10.1093/clinchem/hvac171] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2022] [Accepted: 08/30/2022] [Indexed: 01/07/2023]
Abstract
BACKGROUND Identification of hemoglobin (Hb) variants is of significant value in the clinical diagnosis of hemoglobinopathy. However, conventional methods for identification of Hb variants in clinical laboratories can be inadequate due to the lack of structural characterization. We describe the use of neutral-coating capillary electrophoresis coupled with high-resolution mass spectrometry (CE-HR-MS) to achieve high-performance top-down identification of Hb variants. METHODS An Orbitrap Q-Exactive Plus mass spectrometer was coupled with an ECE-001 capillary electrophoresis (CE) unit through an EMASS-II ion source. A PS1 neutral-coating capillary was used for CE. Samples of red blood cells were lysed in water and diluted in 10 mM ammonium formate buffer for analysis. Deconvolution of raw mass spectrometry data was carried out to merge multiple charge states and isotopic peaks of an analyte to obtain its monoisotopic mass. RESULTS The neutral-coating CE could baseline separate individual Hb subunits dissociated from intact Hb forms, and the HR-MS could achieve both intact-protein analysis and top-down analysis of analytes. A number of patient samples that contain Hb subunit variants were analyzed, and the variants were successfully identified using the CE-HR-MS method. CONCLUSIONS The CE-HR-MS method has been demonstrated as a useful tool for top-down identification of Hb variants. With the ability to characterize the primary structures of Hb subunits, the CE-HR-MS method has significant advantages to complement or partially replace the conventional methods for the identification of Hb variants.
Collapse
Affiliation(s)
- Ruben Yiqi Luo
- Department of Pathology, School of Medicine, Stanford University, Stanford, CA, USA.,Clinical Laboratories, Stanford Health Care, Palo Alto, CA, USA
| | - Carolyn Wong
- Clinical Laboratories, Stanford Health Care, Palo Alto, CA, USA
| | | | - Bertil E Glader
- Department of Pathology, School of Medicine, Stanford University, Stanford, CA, USA.,Department of Pediatrics, School of Medicine, Stanford University, Stanford, CA, USA
| | - Run-Zhang Shi
- Department of Pathology, School of Medicine, Stanford University, Stanford, CA, USA.,Clinical Laboratories, Stanford Health Care, Palo Alto, CA, USA
| | - James L Zehnder
- Department of Pathology, School of Medicine, Stanford University, Stanford, CA, USA.,Clinical Laboratories, Stanford Health Care, Palo Alto, CA, USA
| |
Collapse
|
2
|
Optimization and Identification of Single Mutation in Hemoglobin Variants with 2,2,2 Trifluoroethanol Modified Digestion Method and Nano-LC Coupled MALDI MS/MS. MOLECULES (BASEL, SWITZERLAND) 2022; 27:molecules27196357. [PMID: 36234894 PMCID: PMC9572498 DOI: 10.3390/molecules27196357] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/05/2022] [Revised: 09/09/2022] [Accepted: 09/21/2022] [Indexed: 12/30/2022]
Abstract
Background: Hemoglobin (Hb) variants arise due to point mutations in globin chains and their pathological treatments rely heavily on the identification of the nature and location of the mutation in the globin chains. Traditional methods for diagnosis such as HPLC and electrophoresis have their own limitations. Therefore, the present study aims to develop and optimize a specific method of sample processing that could lead to improved sequence coverage and analysis of Hb variants by nano LC-MALDI MS/MS. Methods: In our study, we primarily standardized various sample processing methods such as conventional digestion with trypsin followed by 10% acetonitrile treatment, digestion with multiple proteases like trypsin, Glu-C, Lys-C, and trypsin digestion subsequent to 2,2,2 trifluoroethanol (TFE) treatment. Finally, the peptides were identified by LC-MALDI MS/MS. All of these sample processing steps were primarily tested with recombinant Hb samples. After initial optimization, we found that the TFE method was the most suitable one and the efficiency of this method was applied in Hb variant identification based on high sequence coverage. Results: We developed and optimized a method using an organic solvent TFE and heat denaturation prior to digestion, resulting in 100% sequence coverage in the β-chains and 95% sequence coverage in the α-chains, which further helped in the identification of Hb mutations. A Hb variant protein sequence database was created to specify the search and reduce the search time. Conclusion: All of the mutations were identified using a bottom-up non-target approach. Therefore, a sensitive, robust and reproducible method was developed to identify single substitution mutations in the Hb variants from the sequence of the entire globin chains. Biological Significance: Over 330,000 infants are born annually with hemoglobinopathies and it is the major cause of morbidity and mortality in early childhood. Hb variants generally arise due to point mutation in the globin chains. There is high sequence homology between normal Hb and Hb variant chains. Due to this high homology between the two forms, identification of variants by mass spectrometry is very difficult and requires the full sequence coverage of α- and β-chains. As such, there is a need for a suitable method that provides 100% sequence coverage of globin chains for variant analysis by mass spectrometry. Our study provides a simple, robust, and reproducible method that is suitable for LC-MALDI and provides nearly complete sequence coverage in the globin chains. This method may be used in the near future in routine diagnosis for Hb variant analysis.
Collapse
|
3
|
Nguyen MT, Halvorsen TG, Thiede B, Reubsaet L. Smart proteolysis samplers for pre‐lab bottom‐up protein analysis – Performance of on‐paper digestion compared to conventional digestion. SEPARATION SCIENCE PLUS 2022. [DOI: 10.1002/sscp.202100062] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Affiliation(s)
- Minh Thao Nguyen
- Section of Pharmaceutical Chemistry, Department of Pharmacy University of Oslo Oslo Norway
| | | | - Bernd Thiede
- Section of Biochemistry and Molecular Biology, Department of Biosciences University of Oslo Oslo Norway
| | - Léon Reubsaet
- Section of Pharmaceutical Chemistry, Department of Pharmacy University of Oslo Oslo Norway
| |
Collapse
|
4
|
Hollas MAR, Robey M, Fellers R, LeDuc R, Thomas P, Kelleher N. The Human Proteoform Atlas: a FAIR community resource for experimentally derived proteoforms. Nucleic Acids Res 2022; 50:D526-D533. [PMID: 34986596 PMCID: PMC8728143 DOI: 10.1093/nar/gkab1086] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2021] [Revised: 10/06/2021] [Accepted: 11/14/2021] [Indexed: 01/01/2023] Open
Abstract
The Human Proteoform Atlas (HPfA) is a web-based repository of experimentally verified human proteoforms on-line at http://human-proteoform-atlas.org and is a direct descendant of the Consortium of Top-Down Proteomics' (CTDP) Proteoform Atlas. Proteoforms are the specific forms of protein molecules expressed by our cells and include the unique combination of post-translational modifications (PTMs), alternative splicing and other sources of variation deriving from a specific gene. The HPfA uses a FAIR system to assign persistent identifiers to proteoforms which allows for redundancy calling and tracking from prior and future studies in the growing community of proteoform biology and measurement. The HPfA is organized around open ontologies and enables flexible classification of proteoforms. To achieve this, a public registry of experimentally verified proteoforms was also created. Submission of new proteoforms can be processed through email vianrtdphelp@northwestern.edu, and future iterations of these proteoform atlases will help to organize and assign function to proteoforms, their PTMs and their complexes in the years ahead.
Collapse
Affiliation(s)
- Michael A R Hollas
- Departments of Molecular Biosciences, Chemistry, and the Chemistry of Life Processes Institute, Northwestern University, Evanston, IL 60208, USA
| | - Matthew T Robey
- Departments of Molecular Biosciences, Chemistry, and the Chemistry of Life Processes Institute, Northwestern University, Evanston, IL 60208, USA
| | - Ryan T Fellers
- Departments of Molecular Biosciences, Chemistry, and the Chemistry of Life Processes Institute, Northwestern University, Evanston, IL 60208, USA
| | - Richard D LeDuc
- Departments of Molecular Biosciences, Chemistry, and the Chemistry of Life Processes Institute, Northwestern University, Evanston, IL 60208, USA
| | - Paul M Thomas
- Departments of Molecular Biosciences, Chemistry, and the Chemistry of Life Processes Institute, Northwestern University, Evanston, IL 60208, USA
| | - Neil L Kelleher
- Departments of Molecular Biosciences, Chemistry, and the Chemistry of Life Processes Institute, Northwestern University, Evanston, IL 60208, USA
| |
Collapse
|
5
|
Lin Y, Agarwal AM, Marshall AG, Anderson LC. Characterization of Structural Hemoglobin Variants by Top-Down Mass Spectrometry and R Programming Tools for Rapid Identification. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2022; 33:123-130. [PMID: 34955023 DOI: 10.1021/jasms.1c00291] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Hemoglobinopathies are one of the most prevalent genetic disorders, affecting millions throughout the world. These are caused by pathogenic variants in genes that control the production of hemoglobin (Hb) subunits. As the number of known Hb variants has increased, it has become more challenging to obtain unambiguous results from routine chromatographic assays employed in the clinical laboratory. Top-down proteomic analysis of Hb by mass spectrometry is a definitive method to directly characterize the sequences of intact subunits. Here, we apply "chimeric ion loading" to characterize Hb β subunit variants. In this technique, product ions derived from complementary dissociation techniques are accumulated in a multipole storage device before delivery to a 21 T Fourier-transform ion cyclotron resonance mass spectrometer for simultaneous detection. To further improve the efficiency of identification of Hb variants and localization of the mutation site(s), we developed an R programming script, "Variants Identifier", to search top-down data against a database containing accurate intact mass differences and diagnostic ions from investigated Hb variants. A second R script, "PredictDiag", was developed and employed to determine relevant diagnostic ions for additional Hb variants with known sequences. These two R scripts were successfully applied to the identification of a Hb δ-β fusion protein and other Hb variants. The combination of chimeric ion loading and the above R scripts enables rapid and reliable interpretation of top-down mass spectrometry data, regardless of activation type, for Hb variant identification.
Collapse
Affiliation(s)
- Yuan Lin
- Department of Chemistry and Biochemistry, Florida State University, Tallahassee, Florida 32308, United States
| | - Archana M Agarwal
- Department of Pathology, University of Utah School of Medicine, Salt Lake City, Utah 84132, United States
- ARUP Institute for Clinical and Experimental Pathology, Salt Lake City, Utah 84108, United States
| | - Alan G Marshall
- Department of Chemistry and Biochemistry, Florida State University, Tallahassee, Florida 32308, United States
- Ion Cyclotron Resonance Program, National High Magnetic Field Laboratory, Florida State University, Tallahassee, Florida 32310, United States
| | - Lissa C Anderson
- Ion Cyclotron Resonance Program, National High Magnetic Field Laboratory, Florida State University, Tallahassee, Florida 32310, United States
| |
Collapse
|
6
|
Dasauni P, Chhabra V, Kumar G, Kundu S. Advances in mass spectrometric methods for detection of hemoglobin disorders. Anal Biochem 2021; 629:114314. [PMID: 34303693 DOI: 10.1016/j.ab.2021.114314] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2021] [Revised: 07/19/2021] [Accepted: 07/20/2021] [Indexed: 10/20/2022]
Abstract
Hemoglobin disorders are caused due to alterations in the hemoglobin molecules. These disorders are categorized in two broad classes - hemoglobin variants and thalassemias. The hemoglobin variants arise due to point mutations in the alpha (α), beta (β), gamma (γ), delta (δ), or epsilon (ε) globin chains of these proteins, while thalassemias are caused due to the under-production of α or β globin chain. Hemoglobin disorders account for 7 % of the major health issues globally. Mass Spectrometry is an extensively used analytical tool in the field of protein identification, protein-protein interaction, biomarker discovery and diagnosis of several impairments including hemoglobin related disorders. The remarkable advancements in the technology and method development have enormously augmented the clinical significance of mass spectrometry in these fields. The present review describes hemoglobin disorders and the recent advancements in mass spectrometry in the detection of such disorders, including its advantages, lacunae, and future directions. The literature evidence concludes that mass spectrometry can be potentially used as a 'First Line Screening Assay' for the detection of hemoglobin disorders in the near future.
Collapse
Affiliation(s)
- Pushpanjali Dasauni
- Department of Biochemistry, University of Delhi South Campus, New Delhi, 110021, India
| | - Varun Chhabra
- Department of Biochemistry, University of Delhi South Campus, New Delhi, 110021, India
| | - Gaurav Kumar
- Department of Biochemistry, University of Delhi South Campus, New Delhi, 110021, India
| | - Suman Kundu
- Department of Biochemistry, University of Delhi South Campus, New Delhi, 110021, India.
| |
Collapse
|
7
|
Next-Generation Dried Blood Spot Samplers for Protein Analysis: Describing Trypsin-Modified Smart Sampling Paper. SEPARATIONS 2021. [DOI: 10.3390/separations8050066] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
This paper describes smart sampling paper to be used for bottom-up protein analysis. Four different manners to immobilize trypsin on cellulose were evaluated. Untreated paper, potassium-periodate-functionalized paper (with and without post-immobilization reduction) and 2-hydroxyethyl methacrylate (HEMA)/2-vinyl-4,4-dimethylazlactone (VDM)-functionalized paper were all used to immobilize trypsin. For the evaluation, Coomassie Brilliant Blue staining of proteins on paper and the BAEE trypsin activity assay needed to be modified. These methods allowed, together with data from mass spectrometric analysis of cytochrome C digestions, us to acquire fundamental insight into protein binding, and trypsin action and activity on paper. All functionalized discs bind more protein than the untreated discs. Protein binding to functionalized discs is based on both adsorption and covalent binding. Trypsin immobilized on potassium-periodate-functionalized discs exhibits the highest trypsin activity when using cytochrome C as substrate. It is proven that it is trypsin attached to paper (and not desorbed trypsin) which is responsible for the enzyme activity. The use of discs on complex biological samples shows that all functionalized discs are able to digest diluted serum; for the best-performing disc, HEMA-VDM functionalized, up to 200 high-confidence proteins are qualified, showing its potential.
Collapse
|
8
|
He L, Rockwood AL, Agarwal AM, Anderson LC, Weisbrod CR, Hendrickson CL, Marshall AG. Top-down proteomics-a near-future technique for clinical diagnosis? ANNALS OF TRANSLATIONAL MEDICINE 2020; 8:136. [PMID: 32175429 DOI: 10.21037/atm.2019.12.67] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Affiliation(s)
- Lidong He
- Department of Chemistry and Biochemistry, Florida State University, Tallahassee, FL, USA
| | - Alan L Rockwood
- Department of Chemistry and Biochemistry, Florida State University, Tallahassee, FL, USA.,Rockwood Scientific Consulting, Salt Lake City, UT, USA.,University of Utah School of Medicine, Salt Lake City, UT, USA
| | - Archana M Agarwal
- University of Utah School of Medicine, Salt Lake City, UT, USA.,ARUP Institute for Clinical and Experimental Pathology, Salt Lake City, UT, USA
| | - Lissa C Anderson
- National High Magnetic Field Laboratory, Florida State University, Tallahassee, FL, USA
| | - Chad R Weisbrod
- National High Magnetic Field Laboratory, Florida State University, Tallahassee, FL, USA
| | - Christopher L Hendrickson
- Department of Chemistry and Biochemistry, Florida State University, Tallahassee, FL, USA.,National High Magnetic Field Laboratory, Florida State University, Tallahassee, FL, USA
| | - Alan G Marshall
- Department of Chemistry and Biochemistry, Florida State University, Tallahassee, FL, USA.,National High Magnetic Field Laboratory, Florida State University, Tallahassee, FL, USA
| |
Collapse
|
9
|
Sobsey CA, Ibrahim S, Richard VR, Gaspar V, Mitsa G, Lacasse V, Zahedi RP, Batist G, Borchers CH. Targeted and Untargeted Proteomics Approaches in Biomarker Development. Proteomics 2020; 20:e1900029. [DOI: 10.1002/pmic.201900029] [Citation(s) in RCA: 38] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2019] [Revised: 10/10/2019] [Indexed: 01/24/2023]
Affiliation(s)
- Constance A. Sobsey
- Segal Cancer Proteomics CentreLady Davis InstituteJewish General HospitalMcGill University Montreal Quebec H3T 1E2 Canada
| | - Sahar Ibrahim
- Segal Cancer Proteomics CentreLady Davis InstituteJewish General HospitalMcGill University Montreal Quebec H3T 1E2 Canada
| | - Vincent R. Richard
- Segal Cancer Proteomics CentreLady Davis InstituteJewish General HospitalMcGill University Montreal Quebec H3T 1E2 Canada
| | - Vanessa Gaspar
- Segal Cancer Proteomics CentreLady Davis InstituteJewish General HospitalMcGill University Montreal Quebec H3T 1E2 Canada
| | - Georgia Mitsa
- Segal Cancer Proteomics CentreLady Davis InstituteJewish General HospitalMcGill University Montreal Quebec H3T 1E2 Canada
| | - Vincent Lacasse
- Segal Cancer Proteomics CentreLady Davis InstituteJewish General HospitalMcGill University Montreal Quebec H3T 1E2 Canada
| | - René P. Zahedi
- Segal Cancer Proteomics CentreLady Davis InstituteJewish General HospitalMcGill University Montreal Quebec H3T 1E2 Canada
| | - Gerald Batist
- Gerald Bronfman Department of OncologyJewish General HospitalMcGill University Montreal Quebec H4A 3T2 Canada
| | - Christoph H. Borchers
- Segal Cancer Proteomics CentreLady Davis InstituteJewish General HospitalMcGill University Montreal Quebec H3T 1E2 Canada
- Gerald Bronfman Department of OncologyJewish General HospitalMcGill University Montreal Quebec H4A 3T2 Canada
- Department of Data Intensive Science and EngineeringSkolkovo Institute of Science and TechnologySkolkovo Innovation Center Moscow 143026 Russia
| |
Collapse
|
10
|
He L, Rockwood AL, Agarwal AM, Anderson LC, Weisbrod CR, Hendrickson CL, Marshall AG. Diagnosis of Hemoglobinopathy and β-Thalassemia by 21 Tesla Fourier Transform Ion Cyclotron Resonance Mass Spectrometry and Tandem Mass Spectrometry of Hemoglobin from Blood. Clin Chem 2019; 65:986-994. [PMID: 31040099 DOI: 10.1373/clinchem.2018.295766] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2018] [Accepted: 03/28/2019] [Indexed: 12/15/2022]
Abstract
BACKGROUND Hemoglobinopathies and thalassemias are the most common genetically determined disorders. Current screening methods include cation-exchange HPLC and electrophoresis, the results of which can be ambiguous because of limited resolving power. Subsequently, laborious genetic testing is required for confirmation. METHODS We performed a top-down tandem mass spectrometry (MS/MS) approach with a fast data acquisition (3 min), ultrahigh mass accuracy, and extensive residue cleavage by use of positive electrospray ionization 21 Tesla Fourier transform ion cyclotron resonance-tandem mass spectrometry (21 T FT-ICR MS/MS) for hemoglobin (Hb) variant de novo sequencing and β-thalassemia diagnosis. RESULTS We correctly identified all Hb variants in blind analysis of 18 samples, including the first characterization of homozygous Hb Himeji variant. In addition, an Hb heterozygous variant with isotopologue mass spacing as small as 0.0194 Da (Hb AD) was resolved in both precursor ion mass spectrum (MS1) and product ion mass spectrum (MS2). In blind analysis, we also observed that the abundance ratio between intact δ and β subunits (δ/β) or the abundance ratio between intact δ and α subunits (δ/α) could serve to diagnose β-thalassemia trait caused by a mutation in 1 HBB gene. CONCLUSIONS We found that 21 T FT-ICR MS/MS provides a benchmark for top-down MS/MS analysis of blood Hb. The present method has the potential to be translated to lower resolving power mass spectrometers (lower field FT-ICR mass spectrometry and Orbitrap) for Hb variant analysis (by MS1 and MS2) and β-thalassemia diagnosis (MS1).
Collapse
Affiliation(s)
- Lidong He
- Department of Chemistry and Biochemistry, Florida State University, Tallahassee, FL
| | - Alan L Rockwood
- Department of Chemistry and Biochemistry, Florida State University, Tallahassee, FL.,Rockwood Scientific Consulting, Salt Lake City, UT.,University of Utah Health, Salt Lake City, UT
| | - Archana M Agarwal
- University of Utah Health, Salt Lake City, UT.,ARUP Institute for Clinical and Experimental Pathology, Salt Lake City, UT
| | - Lissa C Anderson
- National High Magnetic Field Laboratory, Florida State University, Tallahassee, FL
| | - Chad R Weisbrod
- National High Magnetic Field Laboratory, Florida State University, Tallahassee, FL
| | - Christopher L Hendrickson
- Department of Chemistry and Biochemistry, Florida State University, Tallahassee, FL.,National High Magnetic Field Laboratory, Florida State University, Tallahassee, FL
| | - Alan G Marshall
- Department of Chemistry and Biochemistry, Florida State University, Tallahassee, FL; .,National High Magnetic Field Laboratory, Florida State University, Tallahassee, FL
| |
Collapse
|
11
|
Coelho Graça D, Hartmer R, Jabs W, Scherl A, Clerici L, Samii K, Tsybin YO, Hochstrasser D, Lescuyer P. Detection of Proteoforms Using Top-Down Mass Spectrometry and Diagnostic Ions. Methods Mol Biol 2019; 1959:173-183. [PMID: 30852823 DOI: 10.1007/978-1-4939-9164-8_12] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Characterization of protein structure modifications is an important field in mass spectrometry (MS)-based proteomics. Here, we describe a process to quickly and reliably identify a mass change in a targeted protein sequence by top-down mass spectrometry (TD MS) using electron transfer dissociation (ETD). The step-by-step procedure describes how to develop a TD MS method for data acquisition as well as the data analysis process. The described TD MS workflow utilizes diagnostic ions to characterize an unknown sample in a few hours.
Collapse
Affiliation(s)
- Didia Coelho Graça
- Clinical Proteomics and Chemistry Group, Faculty of Medicine, University of Geneva, Geneva, Switzerland.
- Department of Genetic, Laboratory Medicine and Pathology, Geneva University Hospitals, Geneva, Switzerland.
| | | | - Wolfgang Jabs
- Beuth Hochschule für Technik Berlin, Berlin, Germany
| | - Alexander Scherl
- Clinical Proteomics and Chemistry Group, Faculty of Medicine, University of Geneva, Geneva, Switzerland
- Department of Genetic, Laboratory Medicine and Pathology, Geneva University Hospitals, Geneva, Switzerland
| | - Lorella Clerici
- Department of Genetic, Laboratory Medicine and Pathology, Geneva University Hospitals, Geneva, Switzerland
| | - Kaveh Samii
- Department of Genetic, Laboratory Medicine and Pathology, Geneva University Hospitals, Geneva, Switzerland
- Division of Hematology, Geneva University Hospitals, Geneva, Switzerland
| | | | - Denis Hochstrasser
- Clinical Proteomics and Chemistry Group, Faculty of Medicine, University of Geneva, Geneva, Switzerland
- Department of Genetic, Laboratory Medicine and Pathology, Geneva University Hospitals, Geneva, Switzerland
| | - Pierre Lescuyer
- Clinical Proteomics and Chemistry Group, Faculty of Medicine, University of Geneva, Geneva, Switzerland
- Department of Genetic, Laboratory Medicine and Pathology, Geneva University Hospitals, Geneva, Switzerland
| |
Collapse
|
12
|
Lermyte F, Valkenborg D, Loo JA, Sobott F. Radical solutions: Principles and application of electron-based dissociation in mass spectrometry-based analysis of protein structure. MASS SPECTROMETRY REVIEWS 2018; 37:750-771. [PMID: 29425406 PMCID: PMC6131092 DOI: 10.1002/mas.21560] [Citation(s) in RCA: 61] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/28/2017] [Revised: 01/19/2018] [Accepted: 01/19/2018] [Indexed: 05/11/2023]
Abstract
In recent years, electron capture (ECD) and electron transfer dissociation (ETD) have emerged as two of the most useful methods in mass spectrometry-based protein analysis, evidenced by a considerable and growing body of literature. In large part, the interest in these methods is due to their ability to induce backbone fragmentation with very little disruption of noncovalent interactions which allows inference of information regarding higher order structure from the observed fragmentation behavior. Here, we review the evolution of electron-based dissociation methods, and pay particular attention to their application in "native" mass spectrometry, their mechanism, determinants of fragmentation behavior, and recent developments in available instrumentation. Although we focus on the two most widely used methods-ECD and ETD-we also discuss the use of other ion/electron, ion/ion, and ion/neutral fragmentation methods, useful for interrogation of a range of classes of biomolecules in positive- and negative-ion mode, and speculate about how this exciting field might evolve in the coming years.
Collapse
Affiliation(s)
- Frederik Lermyte
- Biomolecular and Analytical Mass Spectrometry Group, Department of Chemistry, University of Antwerp, Antwerp, Belgium
- Centre for Proteomics, University of Antwerp, Antwerp, Belgium
- School of Engineering, University of Warwick, Coventry, United Kingdom
| | - Dirk Valkenborg
- Centre for Proteomics, University of Antwerp, Antwerp, Belgium
- Interuniversity Institute for Biostatistics and Statistical Bioinformatics, Hasselt University, Agoralaan, Diepenbeek, Belgium
- Applied Bio and Molecular Systems, Flemish Institute for Technological Research (VITO), Mol, Belgium
| | - Joseph A Loo
- Department of Biological Chemistry, David Geffen School of Medicine, University of California-Los Angeles, Los Angeles, California
- UCLA/DOE Institute for Genomics and Proteomics, University of California-Los Angeles, Los Angeles, California
- Department of Chemistry and Biochemistry, University of California-Los Angeles, Los Angeles, California
| | - Frank Sobott
- Biomolecular and Analytical Mass Spectrometry Group, Department of Chemistry, University of Antwerp, Antwerp, Belgium
- Astbury Centre for Structural Molecular Biology, University of Leeds, Leeds, United Kingdom
- School of Molecular and Cellular Biology, University of Leeds, Leeds, United Kingdom
| |
Collapse
|
13
|
Affiliation(s)
- Nicholas
M. Riley
- Department
of Chemistry, University of Wisconsin-Madison, Madison, Wisconsin 53706, United States
- Genome
Center of Wisconsin, University of Wisconsin-Madison, Madison, Wisconsin 53706, United States
| | - Joshua J. Coon
- Department
of Chemistry, University of Wisconsin-Madison, Madison, Wisconsin 53706, United States
- Genome
Center of Wisconsin, University of Wisconsin-Madison, Madison, Wisconsin 53706, United States
- Department
of Biomolecular Chemistry, University of
Wisconsin-Madison, Madison, Wisconsin 53706, United States
- Morgridge
Institute for Research, Madison, Wisconsin 53715, United States
| |
Collapse
|
14
|
Fornelli L, Durbin KR, Fellers RT, Early BP, Greer JB, LeDuc RD, Compton PD, Kelleher NL. Advancing Top-down Analysis of the Human Proteome Using a Benchtop Quadrupole-Orbitrap Mass Spectrometer. J Proteome Res 2016; 16:609-618. [PMID: 28152595 DOI: 10.1021/acs.jproteome.6b00698] [Citation(s) in RCA: 63] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Over the past decade, developments in high resolution mass spectrometry have enabled the high throughput analysis of intact proteins from complex proteomes, leading to the identification of thousands of proteoforms. Several previous reports on top-down proteomics (TDP) relied on hybrid ion trap-Fourier transform mass spectrometers combined with data-dependent acquisition strategies. To further reduce TDP to practice, we use a quadrupole-Orbitrap instrument coupled with software for proteoform-dependent data acquisition to identify and characterize nearly 2000 proteoforms at a 1% false discovery rate from human fibroblasts. By combining a 3 m/z isolation window with short transients to improve specificity and signal-to-noise for proteoforms >30 kDa, we demonstrate improving proteome coverage by capturing 439 proteoforms in the 30-60 kDa range. Three different data acquisition strategies were compared and resulted in the identification of many proteoforms not observed in replicate data-dependent experiments. Notably, the data set is reported with updated metrics and tools including a new viewer and assignment of permanent proteoform record identifiers for inclusion of highly characterized proteoforms (i.e., those with C-scores >40) in a repository curated by the Consortium for Top-Down Proteomics.
Collapse
Affiliation(s)
- Luca Fornelli
- Departments of Chemistry and Molecular Biosciences, Northwestern University , 2170 Campus Drive, Evanston, Illinois 60208, United States
| | - Kenneth R Durbin
- Departments of Chemistry and Molecular Biosciences, Northwestern University , 2170 Campus Drive, Evanston, Illinois 60208, United States
| | - Ryan T Fellers
- Departments of Chemistry and Molecular Biosciences, Northwestern University , 2170 Campus Drive, Evanston, Illinois 60208, United States
| | - Bryan P Early
- Departments of Chemistry and Molecular Biosciences, Northwestern University , 2170 Campus Drive, Evanston, Illinois 60208, United States
| | - Joseph B Greer
- Departments of Chemistry and Molecular Biosciences, Northwestern University , 2170 Campus Drive, Evanston, Illinois 60208, United States
| | - Richard D LeDuc
- Departments of Chemistry and Molecular Biosciences, Northwestern University , 2170 Campus Drive, Evanston, Illinois 60208, United States
| | - Philip D Compton
- Departments of Chemistry and Molecular Biosciences, Northwestern University , 2170 Campus Drive, Evanston, Illinois 60208, United States
| | - Neil L Kelleher
- Departments of Chemistry and Molecular Biosciences, Northwestern University , 2170 Campus Drive, Evanston, Illinois 60208, United States
| |
Collapse
|
15
|
Toby TK, Fornelli L, Kelleher NL. Progress in Top-Down Proteomics and the Analysis of Proteoforms. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2016; 9:499-519. [PMID: 27306313 PMCID: PMC5373801 DOI: 10.1146/annurev-anchem-071015-041550] [Citation(s) in RCA: 382] [Impact Index Per Article: 47.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
From a molecular perspective, enactors of function in biology are intact proteins that can be variably modified at the genetic, transcriptional, or post-translational level. Over the past 30 years, mass spectrometry (MS) has become a powerful method for the analysis of proteomes. Prevailing bottom-up proteomics operates at the level of the peptide, leading to issues with protein inference, connectivity, and incomplete sequence/modification information. Top-down proteomics (TDP), alternatively, applies MS at the proteoform level to analyze intact proteins with diverse sources of intramolecular complexity preserved during analysis. Fortunately, advances in prefractionation workflows, MS instrumentation, and dissociation methods for whole-protein ions have helped TDP emerge as an accessible and potentially disruptive modality with increasingly translational value. In this review, we discuss technical and conceptual advances in TDP, along with the growing power of proteoform-resolved measurements in clinical and translational research.
Collapse
Affiliation(s)
- Timothy K Toby
- Department of Molecular Biosciences, Northwestern University, Evanston, Illinois 60208;
| | - Luca Fornelli
- Department of Chemistry, Northwestern University, Evanston, Illinois 60208
| | - Neil L Kelleher
- Department of Molecular Biosciences, Northwestern University, Evanston, Illinois 60208;
- Department of Chemistry, Northwestern University, Evanston, Illinois 60208
| |
Collapse
|