1
|
Bols ML, Ma J, Rammal F, Plessers D, Wu X, Navarro-Jaén S, Heyer AJ, Sels BF, Solomon EI, Schoonheydt RA. In Situ UV-Vis-NIR Absorption Spectroscopy and Catalysis. Chem Rev 2024; 124:2352-2418. [PMID: 38408190 DOI: 10.1021/acs.chemrev.3c00602] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/28/2024]
Abstract
This review highlights in situ UV-vis-NIR range absorption spectroscopy in catalysis. A variety of experimental techniques identifying reaction mechanisms, kinetics, and structural properties are discussed. Stopped flow techniques, use of laser pulses, and use of experimental perturbations are demonstrated for in situ studies of enzymatic, homogeneous, heterogeneous, and photocatalysis. They access different time scales and are applicable to different reaction systems and catalyst types. In photocatalysis, femto- and nanosecond resolved measurements through transient absorption are discussed for tracking excited states. UV-vis-NIR absorption spectroscopies for structural characterization are demonstrated especially for Cu and Fe exchanged zeolites and metalloenzymes. This requires combining different spectroscopies. Combining magnetic circular dichroism and resonance Raman spectroscopy is especially powerful. A multitude of phenomena can be tracked on transition metal catalysts on various supports, including changes in oxidation state, adsorptions, reactions, support interactions, surface plasmon resonances, and band gaps. Measurements of oxidation states, oxygen vacancies, and band gaps are shown on heterogeneous catalysts, especially for electrocatalysis. UV-vis-NIR absorption is burdened by broad absorption bands. Advanced analysis techniques enable the tracking of coking reactions on acid zeolites despite convoluted spectra. The value of UV-vis-NIR absorption spectroscopy to catalyst characterization and mechanistic investigation is clear but could be expanded.
Collapse
Affiliation(s)
- Max L Bols
- Laboratory for Chemical Technology (LCT), University of Ghent, Technologiepark Zwijnaarde 125, 9052 Ghent, Belgium
| | - Jing Ma
- Department of Microbial and Molecular Systems, Center for Sustainable Catalysis and Engineering, KU Leuven, Celestijnenlaan 200F, B-3001 Leuven, Belgium
| | - Fatima Rammal
- Department of Microbial and Molecular Systems, Center for Sustainable Catalysis and Engineering, KU Leuven, Celestijnenlaan 200F, B-3001 Leuven, Belgium
| | - Dieter Plessers
- Department of Microbial and Molecular Systems, Center for Sustainable Catalysis and Engineering, KU Leuven, Celestijnenlaan 200F, B-3001 Leuven, Belgium
| | - Xuejiao Wu
- Department of Microbial and Molecular Systems, Center for Sustainable Catalysis and Engineering, KU Leuven, Celestijnenlaan 200F, B-3001 Leuven, Belgium
| | - Sara Navarro-Jaén
- Department of Microbial and Molecular Systems, Center for Sustainable Catalysis and Engineering, KU Leuven, Celestijnenlaan 200F, B-3001 Leuven, Belgium
| | - Alexander J Heyer
- Department of Microbial and Molecular Systems, Center for Sustainable Catalysis and Engineering, KU Leuven, Celestijnenlaan 200F, B-3001 Leuven, Belgium
- Department of Chemistry, Stanford University, Stanford, California 94305, United States
| | - Bert F Sels
- Department of Microbial and Molecular Systems, Center for Sustainable Catalysis and Engineering, KU Leuven, Celestijnenlaan 200F, B-3001 Leuven, Belgium
| | - Edward I Solomon
- Department of Chemistry, Stanford University, Stanford, California 94305, United States
| | - Robert A Schoonheydt
- Department of Microbial and Molecular Systems, Center for Sustainable Catalysis and Engineering, KU Leuven, Celestijnenlaan 200F, B-3001 Leuven, Belgium
| |
Collapse
|
3
|
Gheghiani M, Caillol N, McKenna T, Sheibat-Othman N. Online Monitoring of the Particle Size in Semibatch Emulsion Copolymerization Using Spatially Resolved Spectroscopy and Raman Spectroscopy. Ind Eng Chem Res 2021. [DOI: 10.1021/acs.iecr.0c05770] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Manis Gheghiani
- LAGEPP UMR 5007, University of Lyon, University Claude Bernard Lyon 1, CNRS, 69100 Villeurbanne, France
| | | | - Timothy McKenna
- C2P2-LCPP Group, UMR 5265, CPE Lyon, University of Lyon, University Claude Bernard Lyon 1, CNRS, 69100 Villeurbanne, France
| | - Nida Sheibat-Othman
- LAGEPP UMR 5007, University of Lyon, University Claude Bernard Lyon 1, CNRS, 69100 Villeurbanne, France
| |
Collapse
|
4
|
Ferreira C, Cardona J, Agimelen O, Tachtatzis C, Andonovic I, Sefcik J, Chen YC. Quantification of particle size and concentration using in-line techniques and multivariate analysis. POWDER TECHNOL 2020. [DOI: 10.1016/j.powtec.2020.08.015] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
5
|
Postelmans A, Aernouts B, Saeys W. Estimation of Particle Size Distribution from Bulk Scattering Spectra: Validation on Monomodal Suspensions. Anal Chem 2019; 91:10040-10048. [PMID: 31318541 DOI: 10.1021/acs.analchem.9b01913] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
A particle size distribution (PSD) estimation method based on light-scattering properties was validated on experimental visible/near-infrared scattering spectra of polystyrene suspensions, with a nominal particle size ranging from 0.1 to 12 μm in diameter. On the basis of μs and g spectra extracted from double integrating sphere measurements, good PSD estimates were obtained for particles ≥1 μm. The particle volume fraction estimates in the case of μs were close to the target concentrations, although influenced by small baseline fluctuations on the spectra. For submicrometer particles, on the other hand, the non-oscillating μs spectra lack discriminating power, resulting in erroneous PSD estimates. The reduced scattering coefficient spectra (μs') were found less useful for particle size estimation as they lack a characteristic shape, causing an over- or underestimation of the distribution width. In summary, the estimation routine proved to deliver PSD estimates in line with the reference measurements for micrometer-sized or larger particles based on their μs and g scattering spectra. Additional validation on more polydisperse samples forms the next step before going to bimodal PSD estimates.
Collapse
Affiliation(s)
- Annelies Postelmans
- Department of Biosystems , MeBioS, KU Leuven , Kasteelpark Arenberg 30 , 3001 Leuven , Belgium
| | - Ben Aernouts
- Department of Biosystems , MeBioS, KU Leuven , Kasteelpark Arenberg 30 , 3001 Leuven , Belgium.,Department of Biosystems, Biosystems Technology Cluster , KU Leuven Campus Geel , Kleinhoefstraat 4 , 2440 Geel , Belgium
| | - Wouter Saeys
- Department of Biosystems , MeBioS, KU Leuven , Kasteelpark Arenberg 30 , 3001 Leuven , Belgium
| |
Collapse
|