1
|
Cerqueira Caldas GK, de Abreu Souza G, Silva de Menezes A, Ferreira Pereira SR, de Cássia Silva Luz R, Damos FS. Membraneless, self-powered immunosensing of a cardiac biomarker by exploiting a PEC platform based on CaBi 2Ta 2O 9 combined with bismuth oxyiodides. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2023; 15:6541-6550. [PMID: 37990986 DOI: 10.1039/d3ay01309j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2023]
Abstract
This work describes the development of a membraneless, self-powered immunosensor exploiting a photoelectrochemical system based on two photoelectrodes for cardiac troponin I (cTn). An electrode based on CaBi2Ta2O9 combined with bismuth oxyiodides (BiOI/Bi4O5I2/Bi5O7I) was modified with the cTnI antibody (anti-cTnI) and applied in a photoelectrochemical cell as a photoanode. To perform the cTnI detection exploiting a self-powered photoelectrochemical setup, the immunosensor (anti-cTnI/BiOI/Bi4O5I2/Bi5O7I/CaBi2Ta2O9/FTO) was coupled to a photoelectrochemical cell containing a photocathode based on CuBi2O4 (CBO/FTO) for zero-biased photoelectrochemical immunosensing of cardiac troponin I (cTnI) biomarker. For comparison purposes, the photoanode was applied for cTnI detection in a three-electrode electrochemical cell. The spectroscopic, structural, and morphological characteristics of the photoelectrochemical (PEC) materials were evaluated using scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), and X-ray diffraction (XRD). Electrochemical impedance spectroscopy (EIS) measurements were performed in the presence and absence of light to investigate the effects of photons on the charge transfer resistance of the photoanode. The influence of the cTnI biomarker on the photoelectrochemical response of the anti-cTnI antibody-modified photoelectrochemical platform (anti-cTnI/BiOI/Bi4O5I2/Bi5O7I/CaBi2Ta2O9/FTO) was evaluated by measuring the photocurrent of the system. The immunosensor presented a linear response ranging from 1 pg mL-1 to 200 ng mL-1 as well as a mean recovery percentage between 95.7% and 108.0% in real human serum samples for the cTnI biomarker.
Collapse
Affiliation(s)
| | | | - Alan Silva de Menezes
- Department of Physics, Federal University of Maranhão-UFMA, 65080-805, São Luís, MA, Brazil
| | | | | | - Flavio Santos Damos
- Department of Chemistry, Federal University of Maranhão-UFMA, 65080-805, São Luís, MA, Brazil.
| |
Collapse
|
2
|
Wang R, Wang S, Guo W, Zhang T, Kang Q, Wang P, Zhou F, Yang L. Flow injection analysis coupled with photoelectrochemical immunoassay for simultaneous detection of anti-SARS-CoV-2-spike and anti-SARS-CoV-2-nucleocapsid antibodies in serum samples. Anal Chim Acta 2023; 1280:341857. [PMID: 37858551 DOI: 10.1016/j.aca.2023.341857] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2023] [Revised: 09/28/2023] [Accepted: 09/28/2023] [Indexed: 10/21/2023]
Abstract
A thin-layer flow cell of low internal volume (12 μL) is incorporated in a flow injection analysis (FIA) system for simultaneous and real-time photoelectrochemical (PEC) immunoassay of anti-SARS-CoV-2 spike 1 (S1) and anti-SARS-CoV-2 nucleocapsid (N) antibodies. Covalent linkage of S1 and N proteins to two separate polyethylene glycol (PEG)-covered gold nanoparticles (AuNPs)/TiO2 nanotube array (NTA) electrodes affords 10 consecutive analyses with surface regenerations in between. An indium tin oxide (ITO) allows visible light to impinge onto the two electrodes. The detection limits for anti-S1 and anti-N antibodies were estimated to be 177 and 97 ng mL-1, respectively. Such values compare well with those achieved with other reported methods and satisfy the requirement for screening convalescent patients with low antibody levels. Additionally, our method exhibits excellent intra-batch (RSD = 1.3%), inter-batch (RSD = 3.4%), intra-day (RSD = 1.0%), and inter-day (RSD = 1.6%) reproducibility. The obviation of an enzyme label and continuous analysis markedly decreased the assay cost and duration, rendering this method cost-effective. The excellent anti-fouling property of PEG enables accuracy validation by comparing our PEC immunoassays of patient sera to those of ELISA. In addition, the simultaneous detection of two antibodies holds great potential in disease diagnosis and immunity studies.
Collapse
Affiliation(s)
- Ruimin Wang
- Institute of Surface Analysis and Chemical Biology, University of Jinan, Jinan, Shandong, 250022, PR China
| | - Shuai Wang
- Institute of Surface Analysis and Chemical Biology, University of Jinan, Jinan, Shandong, 250022, PR China
| | - Wanze Guo
- Institute of Surface Analysis and Chemical Biology, University of Jinan, Jinan, Shandong, 250022, PR China
| | - Tiantian Zhang
- University Hospital, University of Jinan, Jinan, Shandong, 250022, PR China
| | - Qing Kang
- Institute of Surface Analysis and Chemical Biology, University of Jinan, Jinan, Shandong, 250022, PR China.
| | - Pengcheng Wang
- Institute of Surface Analysis and Chemical Biology, University of Jinan, Jinan, Shandong, 250022, PR China.
| | - Feimeng Zhou
- School of Life Sciences, Tiangong University, Tianjin, 300387, PR China
| | - Lixia Yang
- Key Laboratory of Jiangxi Province for Persistent Pollutants Control and Resources Recycle, Nanchang Hangkong University, Nanchang, 330063, PR China
| |
Collapse
|
3
|
Yu Q, Fu Y, Xiao K, Zhang X, Du C, Chen J. A label-free photoelectrochemical biosensor with ultra-low-background noise for lead ion assay based on the Cu2O-CuO-TiO2 heterojunction. Anal Chim Acta 2022; 1195:339456. [DOI: 10.1016/j.aca.2022.339456] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2021] [Revised: 01/05/2022] [Accepted: 01/05/2022] [Indexed: 11/01/2022]
|