1
|
Sansare A, Arcodia M, Lee SCK, Jeka J, Reimann H. Immediate application of low-intensity electrical noise reduced responses to visual perturbations during walking in individuals with cerebral palsy. J Neuroeng Rehabil 2024; 21:14. [PMID: 38281953 PMCID: PMC10822182 DOI: 10.1186/s12984-023-01299-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2023] [Accepted: 12/19/2023] [Indexed: 01/30/2024] Open
Affiliation(s)
- Ashwini Sansare
- Department of Physical Therapy, University of Delaware, Newark, DE, USA
| | - Maelyn Arcodia
- Department of Kinesiology and Applied Physiology, University of Delaware, Newark, DE, USA
| | - Samuel C K Lee
- Department of Physical Therapy, University of Delaware, Newark, DE, USA
| | - John Jeka
- Department of Kinesiology and Applied Physiology, University of Delaware, Newark, DE, USA
| | - Hendrik Reimann
- Department of Kinesiology and Applied Physiology, University of Delaware, Newark, DE, USA.
| |
Collapse
|
2
|
Severini G, Koenig A, Cajigas I, Lesniewski-Laas N, Niemi J, Bonato P. Subsensory stochastic electrical stimulation targeting muscle afferents alters gait control during locomotor adaptations to haptic perturbations. iScience 2023; 26:107038. [PMID: 37360695 PMCID: PMC10285629 DOI: 10.1016/j.isci.2023.107038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2022] [Revised: 03/20/2023] [Accepted: 06/01/2023] [Indexed: 06/28/2023] Open
Abstract
Subsensory noise stimulation targeting sensory receptors has been shown to improve balance control in healthy and impaired individuals. However, the potential for application of this technique in other contexts is still unknown. Gait control and adaptation rely heavily on the input from proprioceptive organs in the muscles and joints. Here we investigated the use of subsensory noise stimulation as a means to influence motor control by altering proprioception during locomotor adaptations to forces delivered by a robot. The forces increase step length unilaterally and trigger an adaptive response that restores the original symmetry. Healthy participants performed two adaptation experiments, one with stimulation applied to the hamstring muscles and one without. We found that participants adapted faster but to a lesser extent when undergoing stimulation. We argue that this behavior is because of the dual effect that the stimulation has on the afferents encoding position and velocity in the muscle spindles.
Collapse
Affiliation(s)
- Giacomo Severini
- Department of Physical Medicine & Rehabilitation, Harvard Medical School, Spaulding Rehabilitation Hospital, Boston, MA, USA
- School of Electrical and Electronic Engineering, University College Dublin, Dublin, Dublin 4, Ireland
- Centre for Biomedical Engineering, University College Dublin, Dublin, Dublin 4, Ireland
| | - Alexander Koenig
- Department of Physical Medicine & Rehabilitation, Harvard Medical School, Spaulding Rehabilitation Hospital, Boston, MA, USA
| | - Iahn Cajigas
- Department of Physical Medicine & Rehabilitation, Harvard Medical School, Spaulding Rehabilitation Hospital, Boston, MA, USA
- Department of Neurological Surgery, University of Pennsylvania, Philadelphia, PA, USA
| | | | - James Niemi
- Wyss Institute for Biologically Inspired Engineering, Harvard University, Boston, MA, USA
| | - Paolo Bonato
- Department of Physical Medicine & Rehabilitation, Harvard Medical School, Spaulding Rehabilitation Hospital, Boston, MA, USA
- Wyss Institute for Biologically Inspired Engineering, Harvard University, Boston, MA, USA
| |
Collapse
|
3
|
Decrease in current perception thresholds of A-beta fibers by subthreshold noise stimulation using transcutaneous electrical nerve stimulation. Neuroreport 2023; 34:287-289. [PMID: 36881753 DOI: 10.1097/wnr.0000000000001890] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/09/2023]
Abstract
Developing effective supplements and rehabilitation of the impaired tactile and proprioception sensation is a significant challenge. One potential method for improving these sensations in clinical practice is using stochastic resonance with white noise. While transcutaneous electrical nerve stimulation (TENS) is a simple method, the effect of subthreshold noise stimulation via TENS on sensory nerve thresholds is currently unknown. This study aimed to investigate whether subthreshold TENS can alter afferent nerve thresholds. The electric current perception thresholds (CPT) of A-beta, A-delta, and C fibers were assessed in 21 healthy volunteers during both subthreshold TENS and control conditions. Subthreshold TENS was found to have lower CPT values compared to the control condition for A-beta fibers. No significant differences were observed between subthreshold TENS and control for A-delta and C fibers. Our findings indicated that subthreshold TENS might selectively enhance the function of A-beta fibers.
Collapse
|
4
|
Fava de Lima F, Silva CR, Kohn AF. Transcutaneous spinal direct current stimulation (tsDCS) does not affect postural sway of young and healthy subjects during quiet upright standing. PLoS One 2022; 17:e0267718. [PMID: 35482798 PMCID: PMC9049532 DOI: 10.1371/journal.pone.0267718] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2021] [Accepted: 04/13/2022] [Indexed: 12/02/2022] Open
Abstract
Transcutaneous spinal direct current stimulation (tsDCS) is an effective non-invasive spinal cord electrical stimulation technique to induce neuromodulation of local and distal neural circuits of the central nervous system (CNS). Applied to the spinal cord lumbosacral region, tsDCS changes electrophysiological responses of the motor, proprioceptive and nociceptive pathways, alters the performance of some lower limb motor tasks and can even modulate the behavior of supramedullary neuronal networks. In this study an experimental protocol was conducted to verify if tsDCS (5 mA, 20 minutes) of two different polarizations, applied over the lumbosacral region (tenth thoracic vertebrae (T10)), can induce changes in postural sway oscillations of young healthy individuals during quiet standing. A novel initialization of the electrical stimulation was developed to improve subject blinding to the different stimulus conditions including the sham trials. Measures of postural sway, both global and structural, were computed before, during and following the DC stimulation period. The results indicated that, for the adopted conditions, tsDCS did not induce statistically significant changes in postural sway of young healthy individuals during quiet standing.
Collapse
Affiliation(s)
- Felipe Fava de Lima
- Biomedical Engineering Laboratory, Escola Politécnica, University of São Paulo, São Paulo, Brazil
- * E-mail:
| | - Cristiano Rocha Silva
- Biomedical Engineering Laboratory, Escola Politécnica, University of São Paulo, São Paulo, Brazil
| | - Andre Fabio Kohn
- Biomedical Engineering Laboratory, Escola Politécnica, University of São Paulo, São Paulo, Brazil
| |
Collapse
|
5
|
Zemková E. Physiological Mechanisms of Exercise and Its Effects on Postural Sway: Does Sport Make a Difference? Front Physiol 2022; 13:792875. [PMID: 35283801 PMCID: PMC8908905 DOI: 10.3389/fphys.2022.792875] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2021] [Accepted: 01/03/2022] [Indexed: 11/16/2022] Open
Abstract
While the effect of a variety of exercises on postural balance control has been extensively studied, less attention has been paid to those requiring sport-specific skills. Therefore there is a need to analyze the literature and elucidate changes in postural balance control after exercises performed in conditions close to a particular sport. This scoping review aims (i) To map the literature that addresses postural sway aspects of acute responses to general and sport-specific exercises and their underlying physiological mechanisms, and (ii) To identify gaps in the existing literature and propose future research on this topic. The main literature search conducted on MEDLINE, Web of Science, Scopus, PubMed, and Cochrane Library databases was completed by SpringerLink, Elsevier, and Google Scholar. A total of 60 articles met the inclusion criteria. Findings identified that among a variety of studies evaluating the effects of exercise on postural balance control, only few of them were conducted under sport-specific conditions (i.e., while shooting in biathlon or pentathlon, and after simulated or match-induced protocols in combat and team sports). Therefore, more research is still needed to address this gap in the literature and aim research at investigation of postural sway response to sport-specific exercises. Further analysis of the literature showed that the type, intensity and duration of exercise play a key role in increased postural sway. Whole body and localized muscular fatigue of the trunk, neck and lower limbs is considered to be a main factor responsible for the magnitude of balance impairment in an initial phase of recovery and speed of its readjustment to a pre-exercise level. Other likely factors affecting postural stability are hyperventilation and deterioration of sensorimotor functions, though some contribution of muscle damage, dehydration, hyperthermia or dizziness cannot be excluded. A better understanding of the physiological mechanisms of balance impairment after exercises performed under simulated fatigue induced protocol, close to conditions specific to a particular sport, has implications for designing smart exercise programs tailored to individual needs to improve athlete performance with high demands on postural stability and/or decrease their risk of injuries.
Collapse
Affiliation(s)
- Erika Zemková
- Department of Biological and Medical Sciences, Faculty of Physical Education and Sport, Comenius University in Bratislava, Bratislava, Slovakia
- Sports Technology Institute, Faculty of Electrical Engineering and Information Technology, Slovak University of Technology, Bratislava, Slovakia
- Faculty of Health Sciences, University of Ss. Cyril and Methodius in Trnava, Trnava, Slovakia
- *Correspondence: Erika Zemková, , orcid.org/0000-0003-0938-5691
| |
Collapse
|
6
|
Paillard T. Sensory electrical stimulation and postural balance: a comprehensive review. Eur J Appl Physiol 2021; 121:3261-3281. [PMID: 34351530 DOI: 10.1007/s00421-021-04767-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2021] [Accepted: 07/08/2021] [Indexed: 11/29/2022]
Abstract
PURPOSE Sensory electrical stimulation (SES)-i.e., low-intensity electrical currents below, at, or just above the sensory threshold but below the motor threshold-is mainly used to restore/improve postural balance in pathological and healthy subjects. However, the ins and outs of its application as well as the neurophysiological effects induced are not yet well known. Hence, the aim of this paper was to address the effects of SES on postural balance based on these considerations. METHOD The immediate/concurrent effects (SES applied during postural balance measurements), the acute effects (SES durably applied before measuring postural balance) and the chronic effects (SES included in training/rehabilitation programs, i.e., measurements performed before and after the programs) were analysed with a comprehensive review. RESULT SES can lead to the improvement of postural balance using any of the three applications (immediate/concurrent, acute and chronic), notably in pathological subjects. The beneficial effects of SES can take place at the peripheral (sensory receptors sensitivity), spinal (spinal motoneural excitablity) and supra-spinal (cortex reorganisation or adaptation) levels. In healthy subjects, SES appears interesting, but too few studies have been conducted with this population to report clear results. Moreover, the literature is relatively devoid of comparative studies about the characteristics of the stimulation current (e.g., location, current parameters, duration). CONCLUSION In practice, SES appears to be particularly useful to reinforce or restore the postural function in the immediate/concurrent, acute or chronic application in pathlogical populations while its effects should be confirmed in healthy sujects by future studies. Moreover, future research should focus on the different characteristics of stimulation.
Collapse
Affiliation(s)
- Thierry Paillard
- Laboratoire Mouvement, Equilibre, Performance et Santé, EA 4445, Département STAPS, Université de Pau et des Pays de L'Adour/E2S, ZA Bastillac Sud, 65000, Tarbes, France.
| |
Collapse
|
7
|
Finnemann JJS, Plaisted-Grant K, Moore J, Teufel C, Fletcher PC. Low-level, prediction-based sensory and motor processes are unimpaired in Autism. Neuropsychologia 2021; 156:107835. [PMID: 33794277 DOI: 10.1016/j.neuropsychologia.2021.107835] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2020] [Revised: 03/09/2021] [Accepted: 03/19/2021] [Indexed: 01/08/2023]
Abstract
A new promising account of human brain function suggests that sensory cortices try to optimise information processing via predictions that are based on prior experiences. The brain is thus likened to a probabilistic prediction machine. There has been a growing - though inconsistent - literature to suggest that features of autism spectrum conditions (ASCs) are associated with a deficit in modelling the world through such prediction-based inference. However empirical evidence for differences in low-level sensorimotor predictions in autism is still lacking. One approach to examining predictive processing in the sensorimotor domain is in the context of self-generated (predictable) as opposed to externally-generated (less predictable) effects. We employed two complementary tasks - forcematching and intentional binding - which examine self-versus externally-generated action effects in terms of sensory attenuation and intentional binding respectively in adults with and without autism. The results show that autism was associated with normal levels of sensory attenuation of internally-generated force and with unaltered temporal attraction of voluntary actions and their outcomes. Thus, our results do not support a general deficit in predictive processing in autism.
Collapse
Affiliation(s)
- Johanna J S Finnemann
- Department of Psychiatry, University of Cambridge, Cambridge, CB2 8AH, United Kingdom.
| | - Kate Plaisted-Grant
- Department of Psychology, University of Cambridge, Cambridge, CB2 3EB, United Kingdom
| | - James Moore
- Department of Psychology, Goldsmiths, University of London, London, SE14 6NW, United Kingdom
| | - Christoph Teufel
- Cardiff University Brain Research Imaging Centre (CUBRIC), School of Psychology, Cardiff University, Cardiff, CF24 4HQ, United Kingdom
| | - Paul C Fletcher
- Department of Psychiatry, University of Cambridge, Cambridge, CB2 8AH, United Kingdom; Cambridgeshire and Peterborough NHS Foundation Trust, Cambridge, CB21 5EF, United Kingdom; Wellcome Trust MRC Institute of Metabolic Science, University of Cambridge, Cambridge Biomedical Campus, Cambridge, CB2 0QQ, United Kingdom
| |
Collapse
|
8
|
Rugelj D, Vidovič M, Vauhnik R. Sensory Sub- and Suprathreshold TENS Exhibit No Immediate Effect on Postural Steadiness in Older Adults with No Balance Impairments. BIOMED RESEARCH INTERNATIONAL 2020; 2020:2451291. [PMID: 32190655 PMCID: PMC7064865 DOI: 10.1155/2020/2451291] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 11/07/2019] [Revised: 01/29/2020] [Accepted: 02/05/2020] [Indexed: 11/18/2022]
Abstract
Transcutaneous electrical nerve stimulation (TENS) has been reported to attenuate postural sway; however, the results are inconclusive, with some indicating the effect and others not. The study aimed to evaluate the effect of sensory sub- and suprathreshold low-frequency TENS applied through the plantar surface and posterior aspect of shanks on postural sway. In a group of healthy community-dwelling older adults, TENS was delivered with two different current intensities: (1) subsensory which is below conscious perception and (2) suprasensory threshold which is within the range of conscious perception. Frequencies of the TENS stimulation were sweeping from 5 to 180 Hz and were delivered through the plantar surface and posterior shanks of both legs. Postural sway was measured with a force platform in eyes-open and eyes-closed conditions. To evaluate potential fast adaptability to TENS stimuli, the results were evaluated in two time intervals: 30 seconds and 60 seconds. The results indicated that TENS with the chosen frequencies and electrode placement did not affect postural sway in both the sub- and suprathreshold intensities of TENS, in eyes-open and eyes-closed conditions, and in 30-second and 60-second time intervals. In conclusion, given that in this study sub- and suprathreshold TENS applied via the plantar surface of the feet did not attenuate postural sway, it would be easy to conclude that this type of electrical stimuli is ineffective and no further research is required. We must caution against this, given the specificity of the electrode placements. We recommend that future research be performed consisting of individuals with balance impairments and with different positions of electrodes.
Collapse
Affiliation(s)
- Darja Rugelj
- University of Ljubljana, Faculty of Health Sciences, Biomechanical Laboratory, Ljubljana, Slovenia
| | - Marko Vidovič
- University Rehabilitation Institute, Republic of Slovenia, Ljubljana, Slovenia
| | - Renata Vauhnik
- University of Ljubljana, Faculty of Health Sciences, Biomechanical Laboratory, Ljubljana, Slovenia
- Arthron Institute for Joint and Sports Injuries, Celje, Slovenia
| |
Collapse
|
9
|
Castronovo AM, Giles Doran C, Holden M, Severini G. Analysis of the Effectiveness of Sub-sensory Electrical Noise Stimulation During Visuomotor Adaptations in Different Visual Feedback Conditions. Front Bioeng Biotechnol 2020; 7:399. [PMID: 31921805 PMCID: PMC6915077 DOI: 10.3389/fbioe.2019.00399] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2019] [Accepted: 11/22/2019] [Indexed: 11/25/2022] Open
Abstract
Sub-sensory electrical noise stimulation has been shown to improve motor performance in tasks that mainly rely on proprioceptive feedback. During the execution of movements such as reaching, proprioceptive feedback combines dynamically with visual feedback. It is still unclear whether boosting proprioceptive information in tasks where proprioception mixes with vision can influence motor performance. To better understand this point, we tested the effect of electrical noise stimulation applied superficially to the muscle spindles during four different experiments consisting of isometric reaching tasks under different visual feedback conditions. The first experiment (n = 40) consisted of a reach-and-hold task where subjects had to hold a cursor on a target for 30 s and had visual feedback removed 10 s into the task. Subjects performed 30 repetitions of this task with different stimulation levels, including no stimulation. We observed that trials in which the stimulation was present displayed smaller movement variability. Moreover, we observed a positive correlation between the level of stimulation and task performance. The other three experiments consisted of three versions of an isometric visuomotor adaptation task where subjects were asked to reach to random targets in <1.5 s (otherwise incurring in negative feedback) while overcoming a 45° clockwise rotation in the mapping between the force exerted and the movement of the cursor. The three experiments differed in the visual feedback presented to the subjects, with one group (n = 20) performing the experiment with full visual feedback, one (n = 10) with visual feedback restricted only to the beginning of the trajectory, and one (n = 10) without visual feedback of the trajectory. All subjects performed their experiment twice, with and without stimulation. We did not observe substantial effects of the stimulation when visual feedback was present (either completely or partially). We observed a limited effect of the stimulation in the absence of visual feedback consisting in a significant smaller number of negative-feedback trials and a significant smaller movement time in the first block of the adaptation phase. Our results suggest that sub-sensory stimulation can be beneficial when proprioception is the main feedback modality but mostly ineffective in tasks where visual feedback is actively employed.
Collapse
Affiliation(s)
| | - Ciara Giles Doran
- School of Electrical and Electronic Engineering, University College Dublin, Dublin, Ireland
| | - Méabh Holden
- School of Electrical and Electronic Engineering, University College Dublin, Dublin, Ireland
| | - Giacomo Severini
- School of Electrical and Electronic Engineering, University College Dublin, Dublin, Ireland.,UCD Centre for Biomedical Engineering, University College Dublin, Dublin, Ireland.,Insight Centre for Data Analytics, University College Dublin, Dublin, Ireland
| |
Collapse
|
10
|
Magalhães FH, Mello EM, Kohn AF. Association Between Plantarflexion Torque Variability In Quiet Stance And During Force And Position Tasks. Somatosens Mot Res 2019; 36:241-248. [PMID: 31583939 DOI: 10.1080/08990220.2019.1673720] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
This study examined the association between plantarflexion torque variability during quiet bipedal standing (QS) and during plantarflexion force- and position-matching tasks (FT and PT, respectively). In QS, participants stood still over a force plate, and the mean plantarflexion torque level exerted by each subject in QS (divided by 2 to give the torque due to a single leg) served as the target torque level for right leg FT and PT (performed with the participants seated with their right knee fully extended). During FT participants controlled the force level exerted by the foot against a rigid restraint, while during PT they controlled the angular position of the ankle when sustaining equivalent inertial loads. Standard deviation (SD) of plantarflexion torque was computed from torque signals acquired during periods with and without visual feedback. Significant correlations were found between plantarflexion torque variability in QS and FT (r = 0.8615, p < 0.0001 and r = 0.8838, p = 0.0003 for visual and no visual conditions, respectively) as well as between QS and PT (r = 0.8046, p = 0.003 and r = 0.7332, p = 0.0103 for visual and no visual conditions, respectively), regardless of vision availability. No significant differences were found between the correlations for Qs vs FT and QS vs PT (t(8) = 0.4778, p = 0.6455 and t(8) = 1.6819, p = 0.1310 for visual and no visual conditions, respectively), as assessed by "Hotelling-Williams" tests for equality among dependent correlations. The results indicate that simple measurements of plantarflexion torque fluctuations during FT and PT may be used to estimate balance ability. From a practical standpoint, it is suggested that rehabilitation protocols designed to regain/improve balance function may be based on the performance of FTs or PTs executed in a seated position.
Collapse
Affiliation(s)
- Fernando Henrique Magalhães
- School of Arts, Sciences and Humanities, Universidade de São Paulo, EACH-USP, São Paulo, Brazil.,Biomedical Engineering Laboratory and Neuroscience Program, Universidade de São Paulo, EPUSP, PTC, São Paulo, Brazil
| | - Emanuele Moraes Mello
- Biomedical Engineering Laboratory and Neuroscience Program, Universidade de São Paulo, EPUSP, PTC, São Paulo, Brazil
| | - André Fabio Kohn
- Biomedical Engineering Laboratory and Neuroscience Program, Universidade de São Paulo, EPUSP, PTC, São Paulo, Brazil
| |
Collapse
|
11
|
Silva CR, Magalhães FH, Kohn AF. Fingertip-Coupled Spindle Signaling Does Not Contribute to Reduce Postural Sway Under Light Touch. Front Physiol 2019; 10:1072. [PMID: 31507441 PMCID: PMC6713998 DOI: 10.3389/fphys.2019.01072] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2019] [Accepted: 08/05/2019] [Indexed: 11/13/2022] Open
Abstract
The details of how light touch (LT) of a stable surface reduces postural sway are still not well known. We hypothesized that removal of feedback provided by muscle afferents of the touching fingertip would increase postural sway in standing subjects. Eleven participants stood upright on a force plate with eyes closed and on an unstable surface. The experimental conditions involved two different finger positions: with partial muscle afferents (PMA), which includes sensory information from the fingertip flexor muscles, and no muscle afferents (NMA), without information from either fingertip flexor or extensor muscles. In the control condition, the participants kept the same posture, but with no finger touch (NT). Postural sway in both anteroposterior (AP) and mediolateral (ML) axes were recorded. Results showed that LT decreased all sway quantifiers as compared with the NT condition. The withdrawal of information from the touch finger muscle afferents (NMA condition) did not increase postural sway. Actually, there was a small, albeit statistically significant, decrease in the variability of center of pressure displacement in the AP direction. These results indicate that in some cases, muscle afferent input may either not contribute or even worsen the overall quality of sensory feedback from a given body segment, leading to no improvement or even a slightly decreased performance of the motor control system (evaluated by means of levels of postural sway in the present investigation). The results suggest that non-spindle fingertip afferents provide the bulk of the sensory feedback associated with the fingertip that is touching a ground-referenced object during quiet standing under LT.
Collapse
Affiliation(s)
- Cristiano Rocha Silva
- Biomedical Engineering Laboratory, Universidade de São Paulo, EPUSP, São Paulo, Brazil.,Neuroscience Program, Universidade de São Paulo, São Paulo, Brazil
| | - Fernando Henrique Magalhães
- Biomedical Engineering Laboratory, Universidade de São Paulo, EPUSP, São Paulo, Brazil.,Neuroscience Program, Universidade de São Paulo, São Paulo, Brazil.,School of Arts, Sciences and Humanities, Universidade de São Paulo, EACH-USP, São Paulo, Brazil
| | - André Fabio Kohn
- Biomedical Engineering Laboratory, Universidade de São Paulo, EPUSP, São Paulo, Brazil.,Neuroscience Program, Universidade de São Paulo, São Paulo, Brazil
| |
Collapse
|
12
|
Tenan MS, Tweedell AJ, Haynes CA, Passaro AD. The effect of imperceptible Gaussian tendon vibration on the Hoffmann reflex. Neurosci Lett 2019; 706:123-127. [PMID: 31085290 DOI: 10.1016/j.neulet.2019.05.018] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2018] [Revised: 03/21/2019] [Accepted: 05/10/2019] [Indexed: 11/25/2022]
Abstract
Imperceptible vibratory Gaussian noise stimulation to the periphery is frequently being applied to humans to enhance motor performance. It is commonly theorized that this stimulation creates a Stochastic Resonance-like effect across both sensory and motor systems, but this idea has no empirical support. In contrast, there is substantial work showing that tendon vibration can be both excitatory and inhibitory on the lower motor neuron output. In this work, we demonstrate that delivery of imperceptible vibratory Gaussian noise stimulation to the wrist flexor tendons results in a 27% increase in excitability of the lower motor neuron pool in the median nerve, as evidenced by changes in the Hoffmann reflex. We argue that the well-documented tonic vibration reflex is a sufficient mechanistic explanation for the behavioral changes observed during the introduction of vibratory noise stimulation.
Collapse
Affiliation(s)
- Matthew S Tenan
- U.S. Army Research Laboratory, Human Research and Engineering Directorate, Research Triangle Park, Durham, NC, USA.
| | - Andrew J Tweedell
- U.S. Army Research Laboratory, Human Research and Engineering Directorate, Aberdeen Proving Ground, MD, USA
| | - Courtney A Haynes
- U.S. Army Research Laboratory, Human Research and Engineering Directorate, Aberdeen Proving Ground, MD, USA
| | - Antony D Passaro
- U.S. Army Research Laboratory, Human Research and Engineering Directorate, ARL West, Playa Vista, CA, USA
| |
Collapse
|
13
|
The effects of sub-threshold vibratory noise on visuomotor entrainment during human walking and standing in a virtual reality environment. Hum Mov Sci 2019; 66:587-599. [PMID: 31255870 PMCID: PMC6934930 DOI: 10.1016/j.humov.2019.06.009] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2019] [Revised: 06/13/2019] [Accepted: 06/14/2019] [Indexed: 01/25/2023]
Abstract
Humans will naturally synchronize their posture to the motion of a visual surround, but it is unclear if this visuomotor entrainment can be attenuated with an increased sensitivity to somatosensory information. Sub-threshold vibratory noise applied to the Achilles tendons has proven to enhance ankle proprioception through the phenomenon of stochastic resonance. Our purpose was to compare visuomotor entrainment during walking and standing, and to understand how this entrainment might be attenuated by applying sub-threshold vibratory noise over the Achilles tendons. We induced visuomotor entrainment during standing and treadmill walking for ten subjects (24.5 ± 2.9 years) using a speed-matched virtual hallway with continuous mediolateral perturbations at three different frequencies. Vibrotactile motors over the Achilles tendons provided noise (0-400 Hz) with an amplitude set to 90% of each participant's sensory threshold. Mediolateral sacrum, C7, and head motion was greatly amplified (4-8× on average) at the perturbation frequencies during walking, but was much less pronounced during standing. During walking, individuals with greater mediolateral head motion at the fastest perturbation frequency saw the greatest attenuation of that motion with applied noise. Similarly, during standing, individuals who exhibited greater postural sway (as measured by the center of pressure) also saw the greatest reductions in sway with sub-threshold noise applied in three of our summary metrics. Our results suggest that, at least for healthy young adults, sub-threshold vibratory noise over the Achilles tendons can slightly improve postural control during disruptive mediolateral visual perturbations, but the applied noise does not substantially attenuate visuomotor entrainment during walking or standing.
Collapse
|
14
|
White O, Babič J, Trenado C, Johannsen L, Goswami N. The Promise of Stochastic Resonance in Falls Prevention. Front Physiol 2019; 9:1865. [PMID: 30745883 PMCID: PMC6360177 DOI: 10.3389/fphys.2018.01865] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2018] [Accepted: 12/11/2018] [Indexed: 12/13/2022] Open
Abstract
Multisensory integration is essential for maintenance of motor and cognitive abilities, thereby ensuring normal function and personal autonomy. Balance control is challenged during senescence or in motor disorders, leading to potential falls. Increased uncertainty in sensory signals is caused by a number of factors including noise, defined as a random and persistent disturbance that reduces the clarity of information. Counter-intuitively, noise can be beneficial in some conditions. Stochastic resonance is a mechanism whereby a particular level of noise actually enhances the response of non-linear systems to weak sensory signals. Here we review the effects of stochastic resonance on sensory modalities and systems directly involved in balance control. We highlight its potential for improving sensorimotor performance as well as cognitive and autonomic functions. These promising results demonstrate that stochastic resonance represents a flexible and non-invasive technique that can be applied to different modalities simultaneously. Finally we point out its benefits for a variety of scenarios including in ambulant elderly, skilled movements, sports and to patients with sensorimotor or autonomic dysfunctions.
Collapse
Affiliation(s)
- Olivier White
- INSERM UMR1093-CAPS, Université Bourgogne Franche-Comté, UFR des Sciences du Sport, Dijon, France.,Acquired Brain Injury Rehabilitation, Faculty of Medicine and Health Sciences, School of Health Sciences, University of East Anglia, Norwich Research Park, Norwich, United Kingdom
| | - Jan Babič
- Laboratory for Neuromechanics and Biorobotics, Jožef Stefan Institute, Ljubljana, Slovenia
| | - Carlos Trenado
- Leibniz Research Centre for Working Environment and Human Factors TU Dortmund (ifADO), Institute of Clinical Neuroscience and Medical Psychology, University Hospital Düsseldorf, Düsseldorf, Germany
| | - Leif Johannsen
- Acquired Brain Injury Rehabilitation, Faculty of Medicine and Health Sciences, School of Health Sciences, University of East Anglia, Norwich Research Park, Norwich, United Kingdom
| | - Nandu Goswami
- Otto Loewi Research Center for Vascular Biology, Immunology and Inflammation, Medical University of Graz, Graz, Austria
| |
Collapse
|
15
|
Zarkou A, Lee SCK, Prosser LA, Hwang S, Jeka J. Stochastic resonance stimulation improves balance in children with cerebral palsy: a case control study. J Neuroeng Rehabil 2018; 15:115. [PMID: 30526617 PMCID: PMC6288963 DOI: 10.1186/s12984-018-0467-7] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2018] [Accepted: 11/21/2018] [Indexed: 12/22/2022] Open
Abstract
Background Stochastic Resonance (SR) Stimulation has been used to enhance balance in populations with sensory deficits by improving the detection and transmission of afferent information. Despite the potential promise of SR in improving postural control, its use in individuals with cerebral palsy (CP) is novel. The objective of this study was to investigate the immediate effects of electrical SR stimulation when applied in the ankle muscles and ligaments on postural stability in children with CP and their typically developing (TD) peers. Methods Ten children with spastic diplegia (GMFCS level I- III) and ten age-matched TD children participated in this study. For each participant the SR sensory threshold was determined. Then, five different SR intensity levels (no stimulation, 25, 50, 75, and 90% of sensory threshold) were used to identify the optimal SR intensity for each subject. The optimal SR and no stimulation condition were tested while children stood on top of 2 force plates with their eyes open and closed. To assess balance, the center of pressure velocity (COPV) in anteroposterior (A/P) and medial-lateral (M/L) direction, 95% COP confidence ellipse area (COPA), and A/P and M/L root mean square (RMS) measures were computed and compared. Results For the CP group, SR significantly decreased COPV in A/P direction, and COPA measures compared to the no stimulation condition for the eyes open condition. In the eyes closed condition, SR significantly decreased COPV only in M/L direction. Children with CP demonstrated greater reduction in all the COP measures but the RMS in M/L direction during the eyes open condition compared to their TD peers. The only significant difference between groups in the eyes closed condition was in the COPV in M/L direction. Conclusions SR electrical stimulation may be an effective stimulation approach for decreasing postural sway and has the potential to be used as a therapeutic tool to improve balance. Applying subject-specific SR stimulation intensities is recommended to maximize balance improvements. Overall, balance rehabilitation interventions in CP might be more effective if sensory facilitation methods, like SR, are utilized by the clinicians. Trial registration ClinicalTrials.gov identifier NCT02456376; 28 May 2015 (Retrospectively registered); https://clinicaltrials.gov/ct2/show/NCT02456376.
Collapse
Affiliation(s)
- Anastasia Zarkou
- Spinal Cord Injury Research Laboratory, Crawford Research Institute, Shepherd Center, 2020 Peachtree Rd NW, Atlanta, GA, 30309, USA.
| | - Samuel C K Lee
- Program in Biomechanics and Movement Science & Department of Physical Therapy, University of Delaware, 540 S. College Ave, Newark, DE, 19713, USA.,Shriners Hospital for Children, 3551 North Broad Street, Philadelphia, PA, 19140, USA
| | - Laura A Prosser
- University of Pennsylvania & The Children's Hospital of Philadelphia, 3401 Civic Center Boulevard, Philadelphia, PA, 19104, USA
| | - Sungjae Hwang
- Department of Kinesiology, University of Maryland Eastern Shore, William P. Hytche Center Room 1124, Princess Anne, MD, 21853, USA
| | - John Jeka
- Department of Kinesiology, University of Delaware, 540 S. College Ave, Newark, DE, 19713, USA
| |
Collapse
|
16
|
Zippenfennig C, Niklaus L, Karger K, Milani TL. Subliminal electrical and mechanical stimulation does not improve foot sensitivity in healthy elderly subjects. Clin Neurophysiol Pract 2018; 3:151-158. [PMID: 30560218 PMCID: PMC6222028 DOI: 10.1016/j.cnp.2018.10.001] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2018] [Revised: 09/25/2018] [Accepted: 10/02/2018] [Indexed: 12/27/2022] Open
Abstract
OBJECTIVE Deterioration of cutaneous perception may be one reason for the increased rate of falling in the elderly. The stochastic resonance phenomenon may compensate this loss of information by improving the capability to detect and transfer weak signals. In the present study, we hypothesize that subliminal electrical and mechanical noise applied to the sole of the foot of healthy elderly subjects improves vibration perception thresholds (VPT). METHODS VPTs of 99 healthy elderly subjects were measured at 30 Hz at the heel and first metatarsal head (MET I). Participants were randomly assigned to one of five groups: vibration (Vi-G), current (Cu-G), control (Co-G), placebo-vibration (Pl-Vi), and placebo-current (Pl-Cu). Vi-G and Cu-G were stimulated using 90% (subliminal) of their individual perception thresholds for five minutes in a standing position. Co-G received no stimulation. The placebo groups were treated with mock stimulation. VPTs were measured twice before the intervention (baseline (BASE) and pre-measurement (PRE)), and once after the intervention (post-measurement (POST)). RESULTS Significant differences were found between measurement conditions comparing BASE and POST, and PRE and POST. VPTs between groups within each measurement condition showed no significant differences. Vi-G was the only group that showed significantly higher VPTs in POST compared to BASE and PRE, which contradicts previous studies. CONCLUSION We analyzed increased VPTs after subliminal mechanical stimulation. The pressure load of standing for five minutes combined with subliminal stimulation may have shifted the initial level of mechanoreceptor sensitivity, which may lead to a deterioration of the VPT. The subliminal electrical stimulation had no effect on VPT. SIGNIFICANCE Based on our results, we cannot confirm positive effects of subliminal electrical or mechanical stimulation on the sole of the foot.
Collapse
Affiliation(s)
- Claudio Zippenfennig
- Faculty of Behavioural and Social Sciences, Institute of Human Movement Science and Health, Professorship of Human Locomotion, Chemnitz University of Technology, 09107 Chemnitz, Germany
| | | | | | | |
Collapse
|
17
|
Severini G, Delahunt E. Effect of noise stimulation below and above sensory threshold on postural sway during a mildly challenging balance task. Gait Posture 2018; 63:27-32. [PMID: 29704801 DOI: 10.1016/j.gaitpost.2018.04.031] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/30/2017] [Revised: 03/27/2018] [Accepted: 04/21/2018] [Indexed: 02/02/2023]
Abstract
BACKGROUND Mechanical and electrical sub-sensory noise stimulation applied to the sensory receptors has been shown to improve performance during postural balance tasks. This improvement has been linked with the Stochastic Resonance (SR) phenomenon. It is not clear if noise levels above sensory threshold can also lead to a reduction in postural sway. RESEARCH QUESTION The aim of this study was to investigate the different effects of sub- and super-sensory electrical noise stimulation applied to the Tibialis Anterior muscle during several repetitions of a mildly challenging single-leg postural balance task. METHODS Fifteen healthy individuals participated in this study. Participants performed 25 repetitions of a balance tasks where they leaned forward and maintained a pre-determined position for 20 s. Each participant experienced 5 different stimulation levels (no-stimulation, 70%, 90%, 110% and 130% of their sensory threshold ST) for 5 times in a randomized order. Optimal stimulation (OS) was defined as the stimulation intensity minimizing the standard deviation of postural sway in the anteroposterior direction. RESULTS ∼57% of the participants presented levels of OS below ST. We did not observe a clear SR-effect, characterized by a U-shaped relationship between the performance metric and the stimulation intensity. OS led to a selective improvement in all the anteroposterior posturographic parameters analyzed. Stimulation below ST led to an improvement in most of the balance features, while stimulation above ST led to an increase in postural sway. SIGNIFICANCE Our results suggest that OS can be found both below and above ST although stimulation below ST appears to be more effective in reducing postural sway.
Collapse
Affiliation(s)
- Giacomo Severini
- School of Electrical and Electronic Engineering, University College Dublin, Engineering Building, Belfield Campus, Dublin 4, Dublin, Ireland.
| | - Eamonn Delahunt
- School of Public Health, Physiotherapy and Sport Science, University College Dublin, Belfield Campus, Dublin 4, Dublin, Ireland
| |
Collapse
|
18
|
De Nunzio AM, Yavuz US, Martinez-Valdes E, Farina D, Falla D. Electro-tactile stimulation of the posterior neck induces body anteropulsion during upright stance. Exp Brain Res 2018; 236:1471-1478. [PMID: 29549403 PMCID: PMC5937870 DOI: 10.1007/s00221-018-5229-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2017] [Accepted: 03/06/2018] [Indexed: 12/19/2022]
Abstract
Sensory information conveyed along afferent fibers from muscle and joint proprioceptors play an important role in the control of posture and gait in humans. In particular, proprioceptive information from the neck is fundamental in supplying the central nervous system with information about the orientation and movement of the head relative to the rest of the body. The previous studies have confirmed that proprioceptive afferences originating from the neck region, evoked via muscle vibration, lead to strong body-orienting effects during static conditions (e.g., leaning of the body forwards or backwards, depending on location of vibration). However, it is not yet certain in humans, whether the somatosensory receptors located in the deep skin (cutaneous mechanoreceptors) have a substantive contribution to postural control, as vibratory stimulation encompasses the receptive field of all the somatosensory receptors from the skin to the muscles. The aim of this study was to investigate the postural effect of cutaneous mechanoreceptor afferences using electro-tactile stimulation applied to the neck. Ten healthy volunteers (8M, 2F) were evaluated. The average position of their centre of foot pressure (CoP) was acquired before, during, and after a subtle electro-tactile stimulation over their posterior neck (mean ± SD = 5.1 ± 2.3 mA at 100 Hz—140% of the perception threshold) during upright stance with their eyes closed. The electro-tactile stimulation led to a body-orienting effect with the subjects consistently leaning forward. An average shift of the CoP of 12.1 ± 11.9 mm (mean ± SD) was reported, which significantly (p < 0.05) differed from its average position under a control condition (no stimulation). These results indicate that cutaneous mechanoreceptive inflow from the neck is integrated to control stance. The findings are relevant for the exploitation of electro-tactile stimulation for rehabilitation interventions where induced anteropulsion of the body is desired.
Collapse
Affiliation(s)
- A M De Nunzio
- Centre of Precision Rehabilitation for Spinal Pain (CPR Spine), School of Sport, Exercise and Rehabilitation Sciences, College of Life and Environmental Sciences, University of Birmingham, Birmingham, UK.
| | - U S Yavuz
- Institute of Applied Mechanics, University of Stuttgart, Stuttgart, Germany
| | - E Martinez-Valdes
- Centre of Precision Rehabilitation for Spinal Pain (CPR Spine), School of Sport, Exercise and Rehabilitation Sciences, College of Life and Environmental Sciences, University of Birmingham, Birmingham, UK
| | - D Farina
- Department of Bioengineering, Imperial College London, Royal School of Mines, London, UK
| | - D Falla
- Centre of Precision Rehabilitation for Spinal Pain (CPR Spine), School of Sport, Exercise and Rehabilitation Sciences, College of Life and Environmental Sciences, University of Birmingham, Birmingham, UK
| |
Collapse
|
19
|
Improved proprioceptive function by application of subsensory electrical noise: Effects of aging and task-demand. Neuroscience 2017; 358:103-114. [PMID: 28673710 DOI: 10.1016/j.neuroscience.2017.06.045] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2017] [Revised: 06/21/2017] [Accepted: 06/23/2017] [Indexed: 11/23/2022]
Abstract
The application of subsensory noise stimulation over the lower limbs has been shown to improve proprioception and postural control under certain conditions. Whereas the effect specificity seems to depend on several factors, studies are still needed to determine the appropriate method for training and rehabilitation purposes. In the current study, we investigated whether the application of subsensory electrical noise over the legs improves proprioceptive function in young and older adults. We aimed to provide evidence that stronger and age-related differential effects occur in more demanding tasks. Proprioceptive function was initially assessed by testing the detection of passive ankle movement (kinesthetic perception) in twenty-eight subjects (14 young and 14 older adults). Thereafter, postural control was assessed during tasks with different sensory challenges: i) by removing visual information (eyes closed) and; ii) by moving the visual scene (moving room paradigm). Tests performed with the application of electrical noise stimulation were compared to those performed without noise. The results showed that electrical noise applied over the legs led to a reduction in the response time to kinesthetic perception in both young and older adults. On the other hand, the magnitude of postural sway was reduced by noise stimulation only during a more challenging task, namely, when the optical flow was changing in an unpredictable (nonperiodic) manner. No differential effects of stimulation between groups were observed. These findings suggest that the relevance of proprioceptive inputs in tasks with different challenges, but not the subjects' age, is a determining factor for sensorimotor improvements due to electrical noise stimulation.
Collapse
|
20
|
Suda EY, Sacco ICN, Hirata RP, Samani A, Kawamura TT, Madeleine P. Later stages of diabetic neuropathy affect the complexity of the neuromuscular system at the knee during low-level isometric contractions. Muscle Nerve 2017; 57:112-121. [PMID: 28224646 DOI: 10.1002/mus.25627] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2016] [Revised: 02/13/2017] [Accepted: 02/19/2017] [Indexed: 12/19/2022]
Abstract
INTRODUCTION This study evaluates the complexity of force and surface electromyography (sEMG) during knee extension and flexion at low-level isometric contractions in individuals with different degrees of diabetic peripheral neuropathy (DPN). METHODS Ten control and 38 diabetic participants performed isometric contractions at 10%, 20%, and 30% of maximal voluntary contraction. Knee force and multichannel sEMG from vastus lateralis (VL) and biceps femoris were acquired. The SD of force and sample entropy (SaEn) of both force and sEMG were computed. RESULTS Participants with moderate DPN demonstrated high force-SD and low force-SaEn. Severely affected participants showed low SaEn in VL at all force levels. DISCUSSION DPN affects the complexity of the neuromuscular system at the knee for the extension task during low-level isometric contractions, with participants in the later stages of the disease (moderate and severe) demonstrating most of the changes. Muscle Nerve 57: 112-121, 2018.
Collapse
Affiliation(s)
- Eneida Y Suda
- Laboratory of Biomechanics of Human Movement, Department of Physical Therapy, Speech and Occupational Therapy, School of Medicine, University of Sao Paulo, Sao Paulo, Brazil
| | - Isabel C N Sacco
- Laboratory of Biomechanics of Human Movement, Department of Physical Therapy, Speech and Occupational Therapy, School of Medicine, University of Sao Paulo, Sao Paulo, Brazil
| | - Rogerio P Hirata
- SMI, Department of Health Science and Technology, Faculty of Medicine, Aalborg University, Fredrik Bajers Vej 7 D-3, 9220, Aalborg East, Denmark
| | - Afshin Samani
- SMI, Department of Health Science and Technology, Faculty of Medicine, Aalborg University, Fredrik Bajers Vej 7 D-3, 9220, Aalborg East, Denmark
| | - Thiago T Kawamura
- Laboratory of Biomechanics of Human Movement, Department of Physical Therapy, Speech and Occupational Therapy, School of Medicine, University of Sao Paulo, Sao Paulo, Brazil
| | - Pascal Madeleine
- SMI, Department of Health Science and Technology, Faculty of Medicine, Aalborg University, Fredrik Bajers Vej 7 D-3, 9220, Aalborg East, Denmark
| |
Collapse
|
21
|
Woo MT, Davids K, Liukkonen J, Orth D, Chow JY, Jaakkola T. Effects of different lower-limb sensory stimulation strategies on postural regulation-A systematic review and meta-analysis. PLoS One 2017; 12:e0174522. [PMID: 28355265 PMCID: PMC5371369 DOI: 10.1371/journal.pone.0174522] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2016] [Accepted: 03/10/2017] [Indexed: 11/23/2022] Open
Abstract
Systematic reviews of balance control have tended to only focus on the effects of single lower-limb stimulation strategies, and a current limitation is the lack of comparison between different relevant stimulation strategies. The aim of this systematic review and meta-analysis was to examine evidence of effects of different lower-limb sensory stimulation strategies on postural regulation and stability. Moderate- to high- pooled effect sizes (Unbiased (Hedges’ g) standardized mean differences (SMD) = 0.31–0.66) were observed with the addition of noise in a Stochastic Resonance Stimulation Strategy (SRSS), in three populations (i.e., healthy young adults, older adults, and individuals with lower-limb injuries), and under different task constraints (i.e., unipedal, bipedal, and eyes open). A Textured Material Stimulation Strategy (TMSS) enhanced postural control in the most challenging condition—eyes-closed on a stable surface (SMD = 0.61), and in older adults (SMD = 0.30). The Wearable Garments Stimulation Strategy (WGSS) showed no or adverse effects (SMD = -0.68–0.05) under all task constraints and in all populations, except in individuals with lower-limb injuries (SMD = 0.20). Results of our systematic review and meta-analysis revealed that future research could consider combining two or more stimulation strategies in intervention treatments for postural regulation and balance problems, depending on individual needs.
Collapse
Affiliation(s)
- Mei Teng Woo
- Faculty of Sport and Health Sciences, University of Jyväskylä, Jyväskylä, Finland
- School of Sports, Health and Leisure, Republic Polytechnic, Singapore, Singapore
- * E-mail:
| | - Keith Davids
- Centre for Sports Engineering Research, Sheffield Hallam University, Sheffield, United Kingdom
| | - Jarmo Liukkonen
- Faculty of Sport and Health Sciences, University of Jyväskylä, Jyväskylä, Finland
| | - Dominic Orth
- Faculty of Behavioral and Movement Sciences, Vrije Universiteit Amsterdam, Amsterdam, Netherland
| | - Jia Yi Chow
- Physical Education and Sports Science, National Institute of Education, Nanyang Technological University, Singapore, Singapore
| | - Timo Jaakkola
- Faculty of Sport and Health Sciences, University of Jyväskylä, Jyväskylä, Finland
| |
Collapse
|
22
|
Taki C, Shiozawa N, Kimura T. Application of Minute Electrical Noise to Muscle Proprioception Modulates Excitability of Alpha Motor Neuron Group. ADVANCED BIOMEDICAL ENGINEERING 2017. [DOI: 10.14326/abe.6.37] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Affiliation(s)
- Chinami Taki
- Graduate School of Human Development and Environment, Kobe University
| | | | - Tetsuya Kimura
- Graduate School of Human Development and Environment, Kobe University
| |
Collapse
|
23
|
Borel L, Ribot-Ciscar E. Improving postural control by applying mechanical noise to ankle muscle tendons. Exp Brain Res 2016; 234:2305-14. [PMID: 27021075 DOI: 10.1007/s00221-016-4636-2] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2015] [Accepted: 03/18/2016] [Indexed: 10/22/2022]
Abstract
The application of subthreshold mechanical vibrations with random frequencies (white mechanical noise) to ankle muscle tendons is known to increase muscle proprioceptive information and to improve the detection of ankle movements. The aim of the present study was to analyze the effect of this mechanical noise on postural control, its possible modulation according to the sensory strategies used for postural control, and the consequences of increasing postural difficulty. The upright stance of 20 healthy young participants tested with their eyes closed was analyzed during the application of four different levels of noise and compared to that in the absence of noise (control) in three conditions: static, static on foam, and dynamic (sinusoidal translation). The quiet standing condition was conducted with the eyes open and closed to determine the subjects' visual dependency to maintain postural stability. Postural performance was assessed using posturographic and motion analysis evaluations. The results in the static condition showed that the spectral power density of body sway significantly decreased with an optimal level of noise and that the higher the spectral power density without noise, the greater the noise effect, irrespective of visual dependency. Finally, noise application was ineffective in the foam and dynamic conditions. We conclude that the application of mechanical noise to ankle muscle tendons is a means to improve quiet standing only. These results suggest that mechanical noise stimulation may be more effective in more impaired populations.
Collapse
Affiliation(s)
- Liliane Borel
- Aix-Marseille Université, CNRS, NIA UMR 7260, Case B, Centre Saint-Charles, Place Victor Hugo, 13331, Marseille Cedex 03, France.
| | - Edith Ribot-Ciscar
- Aix-Marseille Université, CNRS, NIA UMR 7260, Case B, Centre Saint-Charles, Place Victor Hugo, 13331, Marseille Cedex 03, France
| |
Collapse
|
24
|
Toledo DR, Manzano GM, Barela JA, Kohn AF. Cortical correlates of response time slowing in older adults: ERP and ERD/ERS analyses during passive ankle movement. Clin Neurophysiol 2016; 127:655-663. [DOI: 10.1016/j.clinph.2015.05.003] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2014] [Revised: 04/25/2015] [Accepted: 05/02/2015] [Indexed: 11/25/2022]
|
25
|
Magalhães FH, Elias LA, da Silva CR, de Lima FF, de Toledo DR, Kohn AF. D1 and D2 Inhibitions of the Soleus H-Reflex Are Differentially Modulated during Plantarflexion Force and Position Tasks. PLoS One 2015; 10:e0143862. [PMID: 26599909 PMCID: PMC4658029 DOI: 10.1371/journal.pone.0143862] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2015] [Accepted: 11/10/2015] [Indexed: 01/05/2023] Open
Abstract
Presynaptic inhibition (PSI) has been shown to modulate several neuronal pathways of functional relevance by selectively gating the connections between sensory inputs and spinal motoneurons, thereby regulating the contribution of the stretch reflex circuitry to the ongoing motor activity. In this study, we investigated whether a differential regulation of Ia afferent inflow by PSI may be associated with the performance of two types of plantarflexion sensoriomotor tasks. The subjects (in a seated position) controlled either: 1) the force level exerted by the foot against a rigid restraint (force task, FT); or 2) the angular position of the ankle when sustaining inertial loads (position task, PT) that required the same level of muscle activation observed in FT. Subjects were instructed to maintain their force/position at target levels set at ~10% of maximum isometric voluntary contraction for FT and 90° for PT, while visual feedback of the corresponding force/position signals were provided. Unconditioned H-reflexes (i.e. control reflexes) and H-reflexes conditioned by electrical pulses applied to the common peroneal nerve with conditioning-to-test intervals of 21 ms and 100 ms (corresponding to D1 and D2 inhibitions, respectively) were evoked in a random fashion. A significant main effect for the type of the motor task (FT vs PT) (p = 0.005, η2p = 0.603) indicated that PTs were undertaken with lower levels of Ia PSI converging onto the soleus motoneuron pool. Additionally, a significant interaction between the type of inhibition (D1 vs D2) and the type of motor task (FT vs PT) (p = 0.038, η2p = 0.395) indicated that D1 inhibition was associated with a significant reduction in PSI levels from TF to TP (p = 0.001, η2p = 0.731), whereas no significant difference between the tasks was observed for D2 inhibition (p = 0.078, η2p = 0.305). These results suggest that D1 and D2 inhibitions of the soleus H-reflex are differentially modulated during the performance of plantarflexion FT and PT. The reduced level of ongoing PSI during PT suggests that, in comparison to FT, there is a larger reliance on inputs from muscle spindles primary afferents when the neuromuscular system is required to maintain position-controlled plantarflexion contractions.
Collapse
Affiliation(s)
- Fernando Henrique Magalhães
- School of Arts, Sciences and Humanities, Universidade de São Paulo, EACH-USP, São Paulo, SP, Brazil.,Biomedical Engineering Laboratory, Universidade de São Paulo, EPUSP, Avenida Professor Luciano Gualberto, Travessa 3, n.158, São Paulo, SP, Brazil.,Neuroscience Program, Universidade de São Paulo, São Paulo, SP, Brazil
| | - Leonardo Abdala Elias
- Biomedical Engineering Laboratory, Universidade de São Paulo, EPUSP, Avenida Professor Luciano Gualberto, Travessa 3, n.158, São Paulo, SP, Brazil.,Department of Biomedical Engineering, School of Electrical and Computer Engineering, University of Campinas, Campinas, SP, Brazil
| | - Cristiano Rocha da Silva
- Biomedical Engineering Laboratory, Universidade de São Paulo, EPUSP, Avenida Professor Luciano Gualberto, Travessa 3, n.158, São Paulo, SP, Brazil.,Neuroscience Program, Universidade de São Paulo, São Paulo, SP, Brazil
| | - Felipe Fava de Lima
- Biomedical Engineering Laboratory, Universidade de São Paulo, EPUSP, Avenida Professor Luciano Gualberto, Travessa 3, n.158, São Paulo, SP, Brazil
| | - Diana Rezende de Toledo
- Biomedical Engineering Laboratory, Universidade de São Paulo, EPUSP, Avenida Professor Luciano Gualberto, Travessa 3, n.158, São Paulo, SP, Brazil
| | - André Fabio Kohn
- Biomedical Engineering Laboratory, Universidade de São Paulo, EPUSP, Avenida Professor Luciano Gualberto, Travessa 3, n.158, São Paulo, SP, Brazil.,Neuroscience Program, Universidade de São Paulo, São Paulo, SP, Brazil
| |
Collapse
|
26
|
Mulavara AP, Kofman IS, De Dios YE, Miller C, Peters BT, Goel R, Galvan-Garza R, Bloomberg JJ. Using low levels of stochastic vestibular stimulation to improve locomotor stability. Front Syst Neurosci 2015; 9:117. [PMID: 26347619 PMCID: PMC4547107 DOI: 10.3389/fnsys.2015.00117] [Citation(s) in RCA: 42] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2015] [Accepted: 07/30/2015] [Indexed: 01/06/2023] Open
Abstract
Low levels of bipolar binaural white noise based imperceptible stochastic electrical stimulation to the vestibular system (stochastic vestibular stimulation, SVS) have been shown to improve stability during balance tasks in normal, healthy subjects by facilitating enhanced information transfer using stochastic resonance (SR) principles. We hypothesize that detection of time-critical sub-threshold sensory signals using low levels of bipolar binaural SVS based on SR principles will help improve stability of walking during support surface perturbations. In the current study 13 healthy subjects were exposed to short continuous support surface perturbations for 60 s while walking on a treadmill and simultaneously viewing perceptually matched linear optic flow. Low levels of bipolar binaural white noise based SVS were applied to the vestibular organs. Multiple trials of the treadmill locomotion test were performed with stimulation current levels varying in the range of 0–1500 μA, randomized across trials. The results show that subjects significantly improved their walking stability during support surface perturbations at stimulation levels with peak amplitude predominantly in the range of 100–500 μA consistent with the SR phenomenon. Additionally, objective perceptual motion thresholds were measured separately as estimates of internal noise while subjects sat on a chair with their eyes closed and received 1 Hz bipolar binaural sinusoidal electrical stimuli. The optimal improvement in walking stability was achieved on average with peak stimulation amplitudes of approximately 35% of perceptual motion threshold. This study shows the effectiveness of using low imperceptible levels of SVS to improve dynamic stability during walking on a laterally oscillating treadmill via the SR phenomenon.
Collapse
Affiliation(s)
| | - Igor S Kofman
- Wyle Science Technology and Engineering Group, Houston, TX USA
| | - Yiri E De Dios
- Wyle Science Technology and Engineering Group, Houston, TX USA
| | - Chris Miller
- Wyle Science Technology and Engineering Group, Houston, TX USA
| | - Brian T Peters
- Wyle Science Technology and Engineering Group, Houston, TX USA
| | | | | | - Jacob J Bloomberg
- Johnson Space Center, National Aeronautics and Space Administration, Houston, TX USA
| |
Collapse
|
27
|
Méndez-Balbuena I, Huidobro N, Silva M, Flores A, Trenado C, Quintanar L, Arias-Carrión O, Kristeva R, Manjarrez E. Effect of mechanical tactile noise on amplitude of visual evoked potentials: multisensory stochastic resonance. J Neurophysiol 2015; 114:2132-43. [PMID: 26156387 DOI: 10.1152/jn.00457.2015] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2015] [Accepted: 07/06/2015] [Indexed: 11/22/2022] Open
Abstract
The present investigation documents the electrophysiological occurrence of multisensory stochastic resonance in the human visual pathway elicited by tactile noise. We define multisensory stochastic resonance of brain evoked potentials as the phenomenon in which an intermediate level of input noise of one sensory modality enhances the brain evoked response of another sensory modality. Here we examined this phenomenon in visual evoked potentials (VEPs) modulated by the addition of tactile noise. Specifically, we examined whether a particular level of mechanical Gaussian noise applied to the index finger can improve the amplitude of the VEP. We compared the amplitude of the positive P100 VEP component between zero noise (ZN), optimal noise (ON), and high mechanical noise (HN). The data disclosed an inverted U-like graph for all the subjects, thus demonstrating the occurrence of a multisensory stochastic resonance in the P100 VEP.
Collapse
Affiliation(s)
| | - Nayeli Huidobro
- Instituto de Fisiología, Benemérita Universidad Autónoma de Puebla, Puebla, Mexico
| | - Mayte Silva
- Instituto de Fisiología, Benemérita Universidad Autónoma de Puebla, Puebla, Mexico
| | - Amira Flores
- Instituto de Fisiología, Benemérita Universidad Autónoma de Puebla, Puebla, Mexico
| | - Carlos Trenado
- Institute of Clinical Neuroscience, Heinrich Heine University, Düsseldorf, Germany
| | - Luis Quintanar
- Facultad de Psicología, Benemérita Universidad Autónoma de Puebla, Puebla, Mexico
| | - Oscar Arias-Carrión
- Unidad de Trastornos del Movimiento y Sueño (TMS), Hospital General Dr. Manuel Gea González/IFC-UNAM, Mexico City, Mexico; and
| | - Rumyana Kristeva
- Department of Neurology, University of Freiburg, Freiburg, Germany
| | - Elias Manjarrez
- Instituto de Fisiología, Benemérita Universidad Autónoma de Puebla, Puebla, Mexico;
| |
Collapse
|
28
|
Magalhães FH, Kohn AF. Effectiveness of electrical noise in reducing postural sway: a comparison between imperceptible stimulation applied to the anterior and to the posterior leg muscles. Eur J Appl Physiol 2014; 114:1129-41. [DOI: 10.1007/s00421-014-2846-5] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2013] [Accepted: 02/04/2014] [Indexed: 11/24/2022]
|
29
|
Mello EM, Magalhães FH, Kohn AF. Larger plantar flexion torque variability implies less stable balance in the young: An association affected by knee position. Hum Mov Sci 2013; 32:1310-24. [DOI: 10.1016/j.humov.2013.05.004] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2012] [Revised: 03/25/2013] [Accepted: 05/15/2013] [Indexed: 10/26/2022]
|
30
|
Watanabe RN, Magalhães FH, Elias LA, Chaud VM, Mello EM, Kohn AF. Influences of premotoneuronal command statistics on the scaling of motor output variability during isometric plantar flexion. J Neurophysiol 2013; 110:2592-606. [DOI: 10.1152/jn.00073.2013] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
This study focuses on neuromuscular mechanisms behind ankle torque and EMG variability during a maintained isometric plantar flexion contraction. Experimentally obtained torque standard deviation (SD) and soleus, medial gastrocnemius, and lateral gastrocnemius EMG envelope mean and SD increased with mean torque for a wide range of torque levels. Computer simulations were performed on a biophysically-based neuromuscular model of the triceps surae consisting of premotoneuronal spike trains (the global input, GI) driving the motoneuron pools of the soleus, medial gastrocnemius, and lateral gastrocnemius muscles, which activate their respective muscle units. Two types of point processes were adopted to represent the statistics of the GI: Poisson and Gamma. Simulations showed a better agreement with experimental results when the GI was modeled by Gamma point processes having lower orders (higher variability) for higher target torques. At the same time, the simulations reproduced well the experimental data of EMG envelope mean and SD as a function of mean plantar flexion torque, for the three muscles. These results suggest that the experimentally found relations between torque-EMG variability as a function of mean plantar flexion torque level depend not only on the intrinsic properties of the motoneuron pools and the muscle units innervated, but also on the increasing variability of the premotoneuronal GI spike trains when their mean rates increase to command a higher plantar flexion torque level. The simulations also provided information on spike train statistics of several hundred motoneurons that compose the triceps surae, providing a wide picture of the associated mechanisms behind torque and EMG variability.
Collapse
Affiliation(s)
- Renato N. Watanabe
- Biomedical Engineering Laboratory, Department of Telecommunication and Control Engineering, Escola Politécnica, University of São Paulo, São Paulo, Brazil
| | - Fernando H. Magalhães
- Biomedical Engineering Laboratory, Department of Telecommunication and Control Engineering, Escola Politécnica, University of São Paulo, São Paulo, Brazil
| | - Leonardo A. Elias
- Biomedical Engineering Laboratory, Department of Telecommunication and Control Engineering, Escola Politécnica, University of São Paulo, São Paulo, Brazil
| | - Vitor M. Chaud
- Biomedical Engineering Laboratory, Department of Telecommunication and Control Engineering, Escola Politécnica, University of São Paulo, São Paulo, Brazil
| | - Emanuele M. Mello
- Biomedical Engineering Laboratory, Department of Telecommunication and Control Engineering, Escola Politécnica, University of São Paulo, São Paulo, Brazil
| | - André F. Kohn
- Biomedical Engineering Laboratory, Department of Telecommunication and Control Engineering, Escola Politécnica, University of São Paulo, São Paulo, Brazil
| |
Collapse
|