1
|
Mazurek A, Malinowski K, Rosenfield K, Capoccia L, Speziale F, de Donato G, Setacci C, Wissgott C, Sirignano P, Tekieli L, Karpenko A, Kuczmik W, Stabile E, Metzger DC, Amor M, Siddiqui AH, Micari A, Pieniążek P, Cremonesi A, Schofer J, Schmidt A, Musialek P. Clinical Outcomes of Second- versus First-Generation Carotid Stents: A Systematic Review and Meta-Analysis. J Clin Med 2022; 11:4819. [PMID: 36013058 PMCID: PMC9409706 DOI: 10.3390/jcm11164819] [Citation(s) in RCA: 31] [Impact Index Per Article: 15.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2022] [Revised: 07/20/2022] [Accepted: 07/29/2022] [Indexed: 01/10/2023] Open
Abstract
Background: Single-cohort studies suggest that second-generation stents (SGS; “mesh stents”) may improve carotid artery stenting (CAS) outcomes by limiting peri- and postprocedural cerebral embolism. SGS differ in the stent frame construction, mesh material, and design, as well as in mesh-to-frame position (inside/outside). Objectives: To compare clinical outcomes of SGS in relation to first-generation stents (FGSs; single-layer) in CAS. Methods: We performed a systematic review and meta-analysis of clinical studies with FGSs and SGS (PRISMA methodology, 3302 records). Endpoints were 30-day death, stroke, myocardial infarction (DSM), and 12-month ipsilateral stroke (IS) and restenosis (ISR). A random-effect model was applied. Results: Data of 68,422 patients from 112 eligible studies (68.2% men, 44.9% symptomatic) were meta-analyzed. Thirty-day DSM was 1.30% vs. 4.11% (p < 0.01, data for SGS vs. FGS). Among SGS, both Casper/Roadsaver and CGuard reduced 30-day DSM (by 2.78 and 3.03 absolute percent, p = 0.02 and p < 0.001), whereas the Gore stent was neutral. SGSs significantly improved outcomes compared with closed-cell FGS (30-day stroke 0.6% vs. 2.32%, p = 0.014; DSM 1.3% vs. 3.15%, p < 0.01). At 12 months, in relation to FGS, Casper/Roadsaver reduced IS (−3.25%, p < 0.05) but increased ISR (+3.19%, p = 0.04), CGuard showed a reduction in both IS and ISR (−3.13%, −3.63%; p = 0.01, p < 0.01), whereas the Gore stent was neutral. Conclusions: Pooled SGS use was associated with improved short- and long-term clinical results of CAS. Individual SGS types, however, differed significantly in their outcomes, indicating a lack of a “mesh stent” class effect. Findings from this meta-analysis may provide clinically relevant information in anticipation of large-scale randomized trials.
Collapse
Affiliation(s)
- Adam Mazurek
- Department of Cardiac and Vascular Diseases, John Paul II Hospital, Jagiellonian University, 31-202 Krakow, Poland
| | - Krzysztof Malinowski
- Department of Bioinformatics and Telemedicine, Faculty of Medicine, Jagiellonian University Medical College, 31-008 Krakow, Poland
| | - Kenneth Rosenfield
- Vascular Surgery, Surgery Department, Massachusetts General Hospital, Boston, MA 02114, USA
| | - Laura Capoccia
- Vascular and Endovascular Surgery Unit, Department of Surgery, Sapienza University of Rome, 00185 Rome, Italy
| | - Francesco Speziale
- Vascular and Endovascular Surgery Unit, Department of Surgery, Sapienza University of Rome, 00185 Rome, Italy
| | | | - Carlo Setacci
- Department of Vascular Surgery, University of Siena, 53100 Siena, Italy
| | - Christian Wissgott
- Institut für Diagnostische und Interventionelle Radiologie/Neuroradiologie, Imland Klinik Rendsburg, 24768 Rendsburg, Germany
| | - Pasqualino Sirignano
- Vascular and Endovascular Surgery Unit, Department of Surgery, Sapienza University of Rome, 00185 Rome, Italy
| | - Lukasz Tekieli
- Department of Interventional Cardiology, John Paul II Hospital, Jagiellonian University, 31-202 Krakow, Poland
| | - Andrey Karpenko
- Centre of Vascular and Hybrid Surgery, E.N. Meshalkin National Medical Research Center, 630055 Novosibirsk, Russia
| | - Waclaw Kuczmik
- Department of General, Vascular Surgery, Angiology and Phlebology, Medical University of Silesia, 40-055 Katowice, Poland
| | | | | | - Max Amor
- Department of Interventional Cardiology, U.C.C.I. Polyclinique d’Essey, 54270 Nancy, France
| | - Adnan H. Siddiqui
- Department of Neurosurgery, SUNY University at Buffalo, Buffalo, NY 14203, USA
| | - Antonio Micari
- Department of Biomedical and Dental Sciences and Morphological and Functional Imaging, University of Messina, 98122 Messina, Italy
| | - Piotr Pieniążek
- Department of Cardiac and Vascular Diseases, John Paul II Hospital, Jagiellonian University, 31-202 Krakow, Poland
- Department of Interventional Cardiology, John Paul II Hospital, Jagiellonian University, 31-202 Krakow, Poland
| | - Alberto Cremonesi
- Cardiovascular Department, Humanitas Gavazzeni Hospital, 24125 Bergamo, Italy
| | - Joachim Schofer
- MVZ-Department Structural Heart Disease, Asklepios Clinic St. Georg, 20099 Hamburg, Germany
| | - Andrej Schmidt
- Department of Angiology, University Hospital Leipzig, 04103 Leipzig, Germany
| | - Piotr Musialek
- Department of Cardiac and Vascular Diseases, John Paul II Hospital, Jagiellonian University, 31-202 Krakow, Poland
| |
Collapse
|
2
|
Pelz DM, Lownie SP, Lee DH, Boulton MR. Plaque morphology (the PLAC Scale) on CT angiography: predicting long-term anatomical success of primary carotid stenting. J Neurosurg 2015; 123:856-61. [DOI: 10.3171/2014.9.jns14811] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
OBJECT
Carotid angioplasty and stenting has emerged as an alternative to carotid endarterectomy for the treatment of atherosclerotic carotid stenosis. Primary carotid stenting, performed using self-expanding stents alone without deliberate use of embolic protection devices and balloon angioplasty, has been shown to be effective and faster, cheaper, and potentially safer than conventional techniques. However, the long-term morphological results of this technique have not been established. The aim of this study was to determine whether preprocedural carotid plaque imaging at the site of maximal stenosis by using CT angiography (CTA) could predict the long-term morphological outcome of primary carotid stenting.
METHODS
One hundred eighty-one patients were treated over an 11-year period. Preprocedural CTA was performed in 102 of these. A morphological scale (the Predicting Long-term outcome with Angioplasty of the Carotid artery [PLAC] Scale), with grades from 0 to 4 and A or B, was used to evaluate the circumferential degree of plaque calcification, and the presence or absence of soft plaque. All patients were followed using duplex carotid ultrasound and plain radiographs. Satisfactory morphological outcome was defined as a peak systolic velocity < 120 cm/s and internal carotid artery/common carotid artery ratio < 1.4.
RESULTS
The average follow-up duration was 29.7 months (median 24.5 months, range 0.3–87 months). Univariate logistic regression demonstrated that a low calcification grade (p < 0.001), less thick calcification (p < 0.001), and moderate amounts of soft plaque (p < 0.001) are factors that are highly associated with good long-term outcome. Multivariate analyses confirmed that these factors are independent of each other in predicting outcome.
CONCLUSIONS
The long-term morphological outcome of primary carotid stenting was predicted with considerable accuracy by using a straightforward CTA carotid plaque grading scale.