1
|
Alpay K, Nania A, Raj R, Numminen J, Parkkola R, Rautio R, Downer J. Long term WEB results - still going strong at 5 years? Interv Neuroradiol 2024; 30:517-523. [PMID: 36397733 PMCID: PMC11483733 DOI: 10.1177/15910199221139542] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2022] [Accepted: 10/31/2022] [Indexed: 02/17/2024] Open
Abstract
OBJECTIVE The aim of our multi-center study is to examine 5-year radiological outcomes of intracranial aneurysms (IAs) treated with the Woven EndoBridge (WEB). METHODS All patients treated with WEB between January 2013 and December 2016 were included. Patient and aneurysm characteristic data was collected from the electronic patient record. Aneurysm occlusion was assessed using a 3-grade scale: complete occlusion, neck remnant, and aneurysm remnant. Complete occlusion and neck remnant were considered as adequate occlusion, whereas aneurysm remnant was assessed as an inadequate occlusion. RESULTS A total of 66 patients (72.7% female) with 66 IAs (n = 25 acutely ruptured) were treated with WEB. The mean age of patients was 55.6 years (range: 36-71 years). The mean width of the aneurysm neck was 4.5 mm (range: 2-9 mm). 5-year imaging follow-up data was not available for 16.6% patients (n = 11). During the follow up period, 14.5% of IAs (n = 8/55) required retreatment within 24 months of initial treatment with the WEB. A total of 55 IAs were analyzed for 5-year radiological outcome. Of these, including IAs required retreatment, 47.3% of IAs (n = 26/55) were occluded completely, 36.4% (n = 20/55) had neck remnant and 16.3% (n = 9/55) had recanalized. 83.7% of IAs were occluded adequately. None of the IAs rebled after initial treatment with WEB. CONCLUSION WEB can provide acceptable adequate occlusion rates at 5 years. Furthermore, recanalization appears to be unlikely after the first two years post-treatment. The results of large studies are needed to confirm these promising long term radiological outcomes.
Collapse
Affiliation(s)
- Kemal Alpay
- Department of Radiology, Turku University Hospital, Turku, Finland
| | - Alberto Nania
- Department of Clinical Neurosciences, University of Edinburgh, Edinburgh, UK
| | - Rahul Raj
- Department of Neurosurgery, Helsinki University Hospital and University of Helsinki, Finland
| | - Jussi Numminen
- Department of Radiology, Helsinki University Hospital, Helsinki, Finland
| | - Riitta Parkkola
- Department of Radiology, Turku University Hospital, Turku, Finland
| | - Riitta Rautio
- Department of Radiology, Turku University Hospital, Turku, Finland
| | - Jonathan Downer
- Department of Clinical Neurosciences, University of Edinburgh, Edinburgh, UK
| |
Collapse
|
2
|
Yoon JT, Kwon B, Choi JH, Hwang SM, Kim M, Hwang S, Song Y, Lee DH. In Vitro Head-to-Head Comparison of Flow Reduction between Fibered and Non-Fibered Pushable Coils. Neurointervention 2024; 19:31-38. [PMID: 38373422 PMCID: PMC10910180 DOI: 10.5469/neuroint.2024.00031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2024] [Revised: 02/07/2024] [Accepted: 02/12/2024] [Indexed: 02/21/2024] Open
Abstract
PURPOSE To compare the embolization effects of a non-fibered pushable coil with a conventional fibered pushable coil in an in vitro bench-top experiment. MATERIALS AND METHODS A simplified vascular phantom with 4 channels (1 for the non-fibered coil, 1 for the fibered coil, and 2 for continuous circuit flow) was used. A single coil of the longest length was inserted to evaluate the effect of single-coil embolization, and 3 consecutive coils were inserted to assess the effect of multiple-coil embolization. Post-embolization angiography was performed to obtain flow variables (time to peak [TTP], relative peak intensity [rPI], and angiographic flow reduction score [AFRS]) from time density curves. The packing densities of the two coil types were calculated, and the AFRS of each channel was determined by dividing the TTP by the rPI. RESULTS When inserting a single coil, the conventional fibered coil demonstrated better flow reduction, as indicated by a higher AFRS (25.6 vs. 17.4, P=0.034). However, the non-fibered coil exhibited a significantly higher packing density (12.9 vs. 2.4, P=0.001). Similar trends were observed with multiple coils. CONCLUSION The conventional fibered pushable coil showed better flow reduction efficiency, while the non-fibered pushable coil had a higher packing density, likely due to the flexibility of the coil loops. A better understanding of the distinct characteristics of different pushable coils can enhance the outcomes of various vascular embolization.
Collapse
Affiliation(s)
- Jong-Tae Yoon
- Department of Radiology, AMIST, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Boseong Kwon
- Department of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Joon Ho Choi
- Department of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Sun Moon Hwang
- Department of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Mihyeon Kim
- Department of Radiology, AMIST, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Sungbin Hwang
- Department of Radiology, AMIST, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Yunsun Song
- Department of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Deok Hee Lee
- Department of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| |
Collapse
|
3
|
Alpay K, Lindgren A, Rautio R, Parkkola R. The Woven EndoBridge for intracranial aneurysms: Radiological outcomes and factors influencing occlusions at 6 and 24 months. Neuroradiol J 2023; 36:206-212. [PMID: 36028945 PMCID: PMC10034693 DOI: 10.1177/19714009221122216] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
PURPOSE To identify factors influencing short- and mid-term radiological outcomes of intracranial aneurysms (IAs) treated with the Woven EndoBridge (WEB). METHODS A total of 112 patients were treated for IAs with the WEB in at our institution between 2013 and 2020. Patients with 6- and/or 24-months follow-up data were included in the study. Aneurysm occlusion was evaluated using the Raymond-Roy occlusion classification (RR). RR 1 and RR 2 were considered as adequate outcomes, while RR 3 inadequate. RESULTS Data were available for 91 patients (56 females, 62%) at 6 months and 62 of those patients (39 females, 58%) at 24 months. The adequate occlusion (RR 1/RR 2) rate was 89% (n = 81/91) at the 6-months follow-up and 91% (n = 56/62) at the 24-months follow-up. The treatment-related morbidity rate was 4% (n = 4/91), and mortality rate was 1% (n = 1/91). The predictor for inadequate occlusion at the 6-months follow-up was the lobular shape of an aneurysm (p = .01). The aneurysm's height (p = .02), maximal diameter (p = .001), width (p = .002), aspect ratio (p = .03), dome-to-neck ratio (p = .04), and lobular shape (p= .03) were predictive factors for inadequate occlusion at 24 months. All the thrombosed aneurysms (n = 3) showed unfavorable radiological outcomes and required re-treatment within 24 months. None of the patient-related factors were significant. CONCLUSIONS The WEB provides favorable occlusion rates and low complications for both ruptured and unruptured wide-necked IAs. Unfavorable radiological outcomes after WEB treatment may be related to aneurysm morphology and size.
Collapse
Affiliation(s)
- Kemal Alpay
- Department of Radiology, Turku University Hospital, Turku, Finland
| | - Antti Lindgren
- Department of Clinical Radiology, Kuopio University Hospital, Kuopio, Finland
| | - Riitta Rautio
- Department of Radiology, Turku University Hospital, Turku, Finland
- Turku University, Turku, Finland
| | - Riitta Parkkola
- Department of Radiology, Turku University Hospital, Turku, Finland
- Turku University, Turku, Finland
| |
Collapse
|
4
|
Mantilla D, Berod A, Ortiz AF, Vera DD, Nicoud F, Costalat V. Heterogeneous model to evaluate CFD in intracranial bifurcation aneurysms treated with the WEB device to predict angiographic outcome. Interv Neuroradiol 2023:15910199231152514. [PMID: 36734097 DOI: 10.1177/15910199231152514] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023] Open
Abstract
INTRODUCTION The Woven EndoBridge device (WEB) was developed as an alternative to treat Wide-Necked bifurcation aneurysms. It has proven to be effective and safe, however, cases of recanalization have been reported. The purpose of this study was to evaluate and quantify hemodynamic parameters and indexes with CFD of the intracranial aneurysms before and after WEB simulation and to establish their relationship to complete occlusion. MATERIALS AND METHODS Using the heterogeneous model based on the marching cubes algorithm, we created 3D representations of 27 bifurcated intracranial aneurysms treated with the single-layer WEB device to evaluate hemodynamics parameters with CFD, calculated with and without the WEB. RESULTS We observed a lower treatment entry concentration indices (ICI) (2.12 ± 1.31 versus 3.14 ± 0.93, p-value: 0.029) previous to placement of WEB and higher pre-treatment FN (7.56 ± 5.92 versus 3.35 ± 1.51, p-value: 0.018) and post-treatment FN (5.34 ± 5.89 versus 1.99 ± 0.83, p-value: 0.021) for cases with successful occlusions. Lower post-treatment SRa (197.81 ± 221.29 versus 80.02 ± 45.25, p-value: 0.044) and higher pre (0.11 ± 0.07 versus 0.25 ± 0.19, p-value: 0.011) and post-treatment MATT (0.69 ± 1.23 versus 1.02 ± 0.46, p-value: 0.006) were observed in non-occluded cases. CONCLUSIONS In our CFD analysis of the hemodynamic parameters of IA, we found lower ICI before the placement of the WEB device and higher FN pre- and post-treatment for cases with successful occlusions. Non-occluded cases had lower post-treatment SRa and higher pre-treatment and post-treatment MATT.
Collapse
Affiliation(s)
- Daniel Mantilla
- Interventional Radiology Department, 536071Fundación oftalmológica de Santander - Clínica Ardila Lülle. Floridablanca, Colombia
- Interventional Radiology Department, 27968Universidad Autónoma de Bucaramanga, Bucaramanga, Colombia
- Faculté de Sciences, 27037Université de Montpellier, Montpellier, France
| | - Alain Berod
- Sim&Cure, Montpellier, France
- Institut Montpelliérain Alexander, Grothendieck, CNRS, Univ. Montpellier, Montpellier, France
| | - Andrés F Ortiz
- Interventional Radiology Department, 536071Fundación oftalmológica de Santander - Clínica Ardila Lülle. Floridablanca, Colombia
- Interventional Radiology Department, 27968Universidad Autónoma de Bucaramanga, Bucaramanga, Colombia
| | - Daniela D Vera
- Radiology Department, Fundación oftalmológica de Santander, Clínica Ardila Lülle, Floridablanca, Colombia
| | - Franck Nicoud
- Institut Montpelliérain Alexander, Grothendieck, CNRS, Univ. Montpellier, Montpellier, France
| | - Vincent Costalat
- Neuroradiology, Hôpital Güi-de-Chauliac, 26905CHU de Montpellier, Montpellier, France
| |
Collapse
|
5
|
Algin O, Corabay S, Ayberk G. Long-term efficacy and safety of WovenEndoBridge (WEB)-assisted cerebral aneurysm embolization. Interv Neuroradiol 2022; 28:695-701. [PMID: 35098767 PMCID: PMC9706260 DOI: 10.1177/15910199211060970] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2021] [Revised: 10/24/2021] [Accepted: 11/01/2021] [Indexed: 11/16/2022] Open
Abstract
PURPOSE Long-term compaction, compression, migration, and recurrence rates of the WovenEndoBridge devices remain unknown. The purpose of this study was to detect these rates and safety profiles of the WovenEndoBridge within 7 years period. MATERIALS AND METHODS Eighty-three aneurysms of 79 patients treated with the WovenEndoBridge device were retrospectively evaluated using an occlusion scale (e.g. complete occlusion, neck remnant, and aneurysm remnant) on angiography images. RESULTS The residual aneurysm was observed in 11 (13%) aneurysms. The mean and median diameters of the recurrent aneurysms were 6 and 7 mm. Most of the recurrent aneurysms were complex type and/or ruptured. Mean diameters and the neck-to-body ratios of all residual aneurysms in the preoperative imaging exams were above 4 mm and 0.6, respectively. The median values of preoperative height and neck measurements were higher in the recurrent aneurysms than in the adequate occlusion group (p = 0.006, p = 0.019, respectively). There was a statistically significant positive relationship between preoperative height/neck measurements and the mean diameters of residual aneurysms (rs = 0.32 and p = 0.003; rs = 0.28 and p = 0.011, respectively). The WovenEndoBridge compaction/compression and migration were observed in 5 (45%) and 2 (18%) of the recurrent aneurysms. In 7 (64%) of the residual aneurysms, thrombosed areas were found within the aneurysm. In the follow-up period, four aneurysms (4.8%) were retreated due to widened residual aneurysm. Other aneurysms were improved or stable within 7 years. DISCUSSION Our adequate occlusion rate was 87%. Occlusion rates are less favorable than aneurysms with a long height, wide neck, or high neck-to-body ratio. Our study confirms the high safety and efficiency of the WovenEndoBridge. Compaction, compression, and/or migration of the WovenEndoBridge and the presence of intra-aneurysmal thrombosis are the main reasons for the recurrences.
Collapse
Affiliation(s)
- Oktay Algin
- Department of Radiology, City Hospital, Ankara, Turkey
- Department of Radiology, Yildirim Beyazit University, Ankara,
Turkey
- National MR Research Center, Bilkent University, Ankara, Turkey
| | - Seniha Corabay
- Biostatistics Department, Uludag University, Bursa, Turkey
| | - Gıyas Ayberk
- Department of Neurosurgery, Yildirim Beyazit University, Ankara,
Turkey
| |
Collapse
|
6
|
Simgen A, Weyrich A, Dietrich P, Roumia S, Mühl-Benninghaus R, Yilmaz U, Reith W, Kettner M. Treatment of Wide-Necked Cerebral Aneurysms Using the WEB Device Including Flow Alteration Assessment With Color-Coded Imaging: A Single Center Experience. World Neurosurg X 2022; 17:100143. [PMCID: PMC9626383 DOI: 10.1016/j.wnsx.2022.100143] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2022] [Accepted: 09/27/2022] [Indexed: 11/05/2022] Open
Abstract
Objective The Woven EndoBridge (WEB) device (MicroVention, Tustin, CA) has extended the treatment of cerebral aneurysms. Despite the fact that the WEB device has shown promising clinical results, little is known about the caused intra-aneurysmal flow alterations. Here we present our clinical experience with the WEB, including examining various syngo iFlow (Siemens AG, Erlangen, Germany) parameters to predict aneurysm occlusion. Methods We reviewed the data from patients with unruptured cerebral aneurysms treated with a WEB device between 2016 and 2020. Aneurysm occlusion and complications were assessed. Furthermore, different quantitative criteria were evaluated using syngo iFlow after digital subtraction angiography. Results A total of 26 patients hosting 26 cerebral aneurysms met the inclusion criteria. Follow-up was available for 21 patients, with a mean of 7.3 ± 6.3 months. A total of 71.4% (n = 15) of the aneurysms included were located in the anterior and 28.6% (n = 6) in the posterior circulation. Adequate aneurysm occlusion was achieved in 85.7% (n = 18). The iFlow parameters for reduced aneurysm outflow (ID-R) differed significantly from the parameters for reduced inflow (PI-R and PI-D) (P < 0.001). The parameters did not differ significantly between adequately and insufficiently occluded aneurysms. Only a trend towards a lower ID-R of insufficiently occluded aneurysms was observed (P = 0.063), indicating a potential predictive value for insufficient aneurysmal outflow. There was no treatment-related morbidity or mortality. Conclusions The applied syngo iFlow parameters confirmed that flow changes induced by the WEB device significantly affect outflow compared to inflow and have potential predictive value for adequate aneurysm occlusion.
Collapse
Key Words
- cerebral aneurysm
- syngo iflow
- web
- 2d, 2-dimensional
- boss, beaujon occlusion scale score
- cfd, computational fluid dynamics
- dsa, digital subtraction angiography
- id, intensity decrease
- id-r, intensity decrease ratio
- mrs, modified rankin scale
- pi, peak intensity
- pi-d, peak intensity delay
- pi-r, peak intensity ratio
- roi, region of interest
- tdc, time density curve
- ttp, time to peak
- web, woven endobridge
Collapse
Affiliation(s)
- Andreas Simgen
- To whom correspondence should be addressed: Andreas Simgen, M.D., Ph.D.
| | | | | | | | | | | | | | | |
Collapse
|
7
|
Zhang Y, Ma C, Li C, Li X, Liu R, Liu M, Zhu H, Liang F, Wang Y, Dong K, Jiang C, Miao Z, Mo D. Prediction of the trans-stenotic pressure gradient with arteriography-derived hemodynamic features in patients with idiopathic intracranial hypertension. J Cereb Blood Flow Metab 2022; 42:1524-1533. [PMID: 35255760 PMCID: PMC9274861 DOI: 10.1177/0271678x221086408] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The pathogenesis of idiopathic intracranial hypertension (IIH) is attributed to segmental stenosis of the venous sinus. The current treatment paradigm requires a trans-stenotic pressure gradient of ≥8 mmHg or ≥6 mmHg threshold. This study aimed to develop a machine learning screening method to identify patients with IIH using hemodynamic features. A total of 204 venous manometry instances (n = 142, training and validation; n = 62, test) from 135 patients were included. Radiomic features extracted from five arteriography perfusion parameter maps were selected using least absolute shrinkage and selection operator and then entered into support vector machine (SVM) classifiers. The Thr8-23-SVM classifier was created with 23 radiomic features to predict if the pressure gradient was ≥8 mmHg. On an independent test dataset, prediction sensitivity, specificity, accuracy, and AUC were 0.972, 0.846, 0.919, and 0.980, respectively (95% confidence interval: 0.980-1.000). For the 6 mmHg threshold, thr6-28-SVM incorporated 28 features, and its sensitivity, specificity, accuracy, and AUC were 0.923, 0.956, 0.935, and 0.969, respectively (95% confidence interval: 0.927-1.000). The trans-stenotic pressure gradient result was associated with perfusion pattern changes, and SVM classifiers trained with arteriography perfusion map-derived radiomic features could predict the 8 mmHg and 6 mmHg dichotomized trans-stenotic pressure gradients with favorable accuracy.
Collapse
Affiliation(s)
- Yupeng Zhang
- Interventional Neuroradiology Center, Beijing Tiantan Hospital, Capital Medical University, Beijing, China.,Beijing Neurosurgical Institute, Capital Medical University, Beijing, China
| | - Chao Ma
- Beijing Neurosurgical Institute, Capital Medical University, Beijing, China.,Department of Neurosurgery, Beijing Tsinghua Changgung Hospital, School of Clinical Medicine, Tsinghua University, Beijing, China
| | - Changxuan Li
- Department of Neurology, The First Affiliated Hospital of Hainan Medical University, Sanya, Hainan
| | - Xiaoqing Li
- Interventional Neuroradiology Center, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - Raynald Liu
- Interventional Neuroradiology Center, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - Minke Liu
- Department of Neurointerventional Surgery, Affiliated Hospital of Gansu University of Traditional Chinese Medicine, Lanzhou, Gansu
| | - Haoyu Zhu
- Beijing Neurosurgical Institute, Capital Medical University, Beijing, China
| | - Fei Liang
- Beijing Neurosurgical Institute, Capital Medical University, Beijing, China
| | - Yilong Wang
- Department of Neurology, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - Kehui Dong
- Department of Neurology, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - Chuhan Jiang
- Interventional Neuroradiology Center, Beijing Tiantan Hospital, Capital Medical University, Beijing, China.,Beijing Neurosurgical Institute, Capital Medical University, Beijing, China
| | - Zhongrong Miao
- Interventional Neuroradiology Center, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - Dapeng Mo
- Interventional Neuroradiology Center, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| |
Collapse
|
8
|
Simgen A, Mayer C, Kettner M, Mühl-Benninghaus R, Reith W, Yilmaz U. Retrospective analysis of intracranial aneurysms after flow diverter treatment including color-coded imaging (syngo iFlow) as a predictor of aneurysm occlusion. Interv Neuroradiol 2022; 28:190-200. [PMID: 34107790 PMCID: PMC9131503 DOI: 10.1177/15910199211024056] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2021] [Accepted: 05/16/2021] [Indexed: 01/13/2023] Open
Abstract
PURPOSE Flow Diverters (FD) have immensely extended the treatment of cerebral aneurysms in the past years. Complete aneurysm occlusion is a process that often takes a certain amount of time and is usually difficult to predict. Our aim was to investigate different syngo iFlow parameters in order to predict aneurysm occlusion. METHODS Between 2014 and 2018 patients with unruptured cerebral aneurysms treated with a FD were reviewed. Aneurysm occlusion and complication rates have been assessed.In addition, various quantitative criteria were assessed using syngo iFlow before, after the intervention, and after short and long-term digital subtraction angiography (DSA). RESULTS A total of 66 patients hosting 66 cerebral aneurysms were included in this study. 87.9% (n = 58) aneurysms in the anterior and 12.1% (n = 8) in the posterior circulation were treated. Adequate aneurysm occlusion at long-term follow-up (19.05 ± 15.1 months) was achieved in 90.9% (n = 60). Adequately occluded aneurysm revealed a significantly greater peak intensity delay (PI-D, p = 0.008) and intensity decrease ratio (ID-R, p < 0.001) compared to insufficiently occluded aneurysms. Increased intra-aneurysmal contrast agent intensity (>100%) after FD implantation resulted in an ID-R < 1, which was associated with aneurysm growth during follow-up DSA. Retreatment with another FD due to foreshortening and/or aneurysm growth was performed in 10.6% (n = 7). Overall morbidity and mortality rates were 1.5% (n = 1) and 0%. CONCLUSION The applied syngo iFlow parameters were found to be useful in predicting adequate aneurysm occlusion and foresee aneurysm growth, which might indicate the implantation of another FD.
Collapse
Affiliation(s)
- Andreas Simgen
- Departments of Neuroradiology, Saarland University
Hospital, Homburg/Saar, Germany
| | - Christine Mayer
- Departments of Neuroradiology, Saarland University
Hospital, Homburg/Saar, Germany
| | - Michael Kettner
- Departments of Neuroradiology, Saarland University
Hospital, Homburg/Saar, Germany
| | | | - Wolfgang Reith
- Departments of Neuroradiology, Saarland University
Hospital, Homburg/Saar, Germany
| | - Umut Yilmaz
- Departments of Neuroradiology, Saarland University
Hospital, Homburg/Saar, Germany
| |
Collapse
|
9
|
Moore KA, Goyal N, Arthur AS. The Woven EndoBridge embolization device for the treatment of intracranial wide-necked bifurcation aneurysms. Future Cardiol 2021; 17:953-961. [PMID: 33559501 DOI: 10.2217/fca-2020-0173] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Wide-necked bifurcation aneurysms are common when evaluating both ruptured and unruptured intracranial aneurysms and can pose unique challenges. The Woven EndoBridge device (recently approved in the US) is specifically designed for the treatment of these aneurysms. This article serves to introduce the device to a wider audience with a thorough review of the literature, device design, indications, pre-operative evaluation, procedural usage and potential pitfalls.
Collapse
Affiliation(s)
- Kenneth A Moore
- Department of Neurosurgery, University of Tennessee Health Science Center, Memphis, TN 38163, USA
| | - Nitin Goyal
- Department of Neurosurgery, University of Tennessee Health Science Center, Memphis, TN 38163, USA.,Department of Neurology, University of Tennessee Health Science Center, Memphis, TN 38163, USA.,Semmes-Murphey Clinic, Memphis, TN 38120, USA
| | - Adam S Arthur
- Department of Neurosurgery, University of Tennessee Health Science Center, Memphis, TN 38163, USA.,Semmes-Murphey Clinic, Memphis, TN 38120, USA
| |
Collapse
|
10
|
Tropine A, Moussa-Pacha A, Tritt S. Endovascular Treatment of a Direct Carotid Cavernous Sinus Fistula with the Woven EndoBridge Aneurysm Embolization System. Clin Neuroradiol 2020; 30:865-867. [PMID: 32474677 PMCID: PMC7728634 DOI: 10.1007/s00062-020-00914-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2020] [Revised: 04/06/2020] [Accepted: 05/11/2020] [Indexed: 11/29/2022]
Affiliation(s)
- Andrei Tropine
- Institute for diagnostic and interventional Radiology and Neuroradiology, Helios HSK Wiesbaden, Wiesbaden, Germany.
| | - Abdul Moussa-Pacha
- Institute for diagnostic and interventional Radiology and Neuroradiology, Helios HSK Wiesbaden, Wiesbaden, Germany
| | - Stephanie Tritt
- Institute for diagnostic and interventional Radiology and Neuroradiology, Helios HSK Wiesbaden, Wiesbaden, Germany
| |
Collapse
|