Banerjee J, Khatib N, Mansfield RC, Sathiyamurthy S, Kariholu U, Lees C. Continuous non-invasive measurement of cardiac output in neonatal intensive care using regional impedance cardiography: a prospective observational study.
Arch Dis Child Fetal Neonatal Ed 2024;
109:450-455. [PMID:
38123965 DOI:
10.1136/archdischild-2023-325941]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/10/2023] [Accepted: 12/02/2023] [Indexed: 12/23/2023]
Abstract
OBJECTIVES
To compare agreement between echocardiography and regional impedance cardiography (RIC)-derived cardiac output (CO), and to construct indicative normative ranges of CO for gestational age groups.
DESIGN, SETTING AND PARTICIPANTS
Prospective cohort observational study performed in a tertiary centre in London, UK, including neonates born between 25 and 42 weeks' gestational age.
EXPOSURES
Neonates on the postnatal ward had 2 hours of RIC monitoring; neonates in intensive care had RIC monitoring for the first 72 hours, then weekly for 2 hours, with concomitant echocardiography measures.
MAIN OUTCOMES AND MEASURES
RIC was used to measure CO continuously. Statistical analyses were performed using R (V.4.2.2; R Core Team 2022). RIC-derived CO and echocardiography-derived CO were compared using Pearson's correlations and Bland-Altman analyses. Differences in RIC-derived CO between infants born extremely, very and late preterm were assessed using analyses of variance and mixed-effects modelling.
RESULTS
127 neonates (22 extremely, 46 very, 29 late preterm and 30 term) were included. RIC and echocardiography-measured weight-adjusted CO were correlated (r=0.62, p<0.001) with a Bland-Altman bias of -31 mL/min/kg (limits of agreement -322 to 261 mL/min/kg). The RIC-derived CO fell over 12 hours, then increased until 72 hours after birth. The 72-hour weight-adjusted mean CO was higher in extremely preterm (424±158 mL/min/kg) compared with very (325±131 mL/min/kg, p<0.001) and late preterm (237±81 mL/min/kg, p<0.001) neonates; this difference disappeared by 2-3 weeks of age.
CONCLUSIONS
RIC is valid for continuous, non-invasive CO measurement in neonates. Indicative normative CO ranges could help clinicians to make more informed haemodynamic management decisions, which should be explored in future studies.
TRIAL REGISTRATION NUMBER
NCT04064177.
Collapse