1
|
Bohra A, Vasudevan A, Kutaiba N, Van Langenberg DR. Challenges and Strategies to Optimising the Quality of Small Bowel Magnetic Resonance Imaging in Crohn’s Disease. Diagnostics (Basel) 2022; 12:diagnostics12102533. [PMID: 36292222 PMCID: PMC9600769 DOI: 10.3390/diagnostics12102533] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2022] [Revised: 10/03/2022] [Accepted: 10/17/2022] [Indexed: 11/21/2022] Open
Abstract
Magnetic resonance enterography (MRE) is one of the most highly utilised tools in the assessment of patients with small bowel Crohn’s disease (CD). As a non-invasive modality, it has both patient and procedure-related advantages over ileocolonoscopy which is the current gold standard for Crohn’s disease activity assessment. MRE relies upon high-quality images to ensure accurate disease activity assessment; however, few studies have explored the impact of image quality on the accuracy of small bowel CD activity assessment. Bowel distension and motion artifacts are two key imaging parameters that impact the quality of images obtained through MRE. Multiple strategies have been employed to both minimise the effects of motion artifacts and improve bowel distension. This review discusses the definitions of bowel distension and motion artifacts within the literature with a particular focus on current strategies to improve bowel distension and limit motion artifacts in MRE.
Collapse
Affiliation(s)
- Anuj Bohra
- Department of Gastroenterology, Eastern Health, Box Hill 3128, Australia
- Correspondence:
| | - Abhinav Vasudevan
- Department of Gastroenterology, Eastern Health, Box Hill 3128, Australia
| | - Numan Kutaiba
- Department of Radiology, Eastern Health, Box Hill 3128, Australia
| | | |
Collapse
|
2
|
Glutig K, Mentzel HJ, Prüfer FH, Teichgräber U, Obmann MM, Krämer M. RAVE-T2/T1 - Feasibility of a new hybrid MR-sequence for free-breathing abdominal MRI in children and adolescents. Eur J Radiol 2021; 143:109903. [PMID: 34392003 DOI: 10.1016/j.ejrad.2021.109903] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2021] [Revised: 07/22/2021] [Accepted: 08/04/2021] [Indexed: 11/28/2022]
Abstract
BACKGROUND The new radial volumetric encoding RAVE-T2/T1 hybrid sequence is a modern three-dimensional sequence with multiparametric approach, which includes T2- and T1-weighted contrasts obtained in identical slice position during one measurement. However, the RAVE-T2/T1 hybrid sequence is not yet being used in clinical routine. PURPOSE The aim of this study was to evaluate the RAVE-T2/T1 hybrid sequence in a pediatric population with a clinical indication for an abdominal MRI examination to demonstrate that the hybrid imaging may be less challenging to perform on children. MATERIALS AND METHODS Our retrospective observational study included pediatric patients of all age groups and required for an abdominal MRI examination. Non-contrast standard axial T1 DIXON and non-contrast RAVE-T2/T1 hybrid sequence were obtained at 3 T. MRI studies were analyzed independently by two pediatric radiologists using a 5-point Likert-type scale in five different categories. T1- and T2-weighted sequences were each compared with the RAVE-T2/T1-sequence using a Wilcoxon signed-rank test. RESULTS The analysis included 15 children (mean age, 11 years and 4 months, 7 girls and 8 boys). The Cohens Kappa of interrater agreement measured 0.62. The T2 weighted part of the RAVE-T2/T1 sequence was significantly better than the standard T2 HASTE sequence in four of five image quality categories: overall image quality (2.2 ± 0.7 vs 1.8 ± 0,7, p = 0.03), respiratory motion artefacts (3.8 ± 0.4 vs 2.0 ± 0.7, p <= 0.01), portal vein clarity (3.3 ± 0.8 vs 2.2 ± 0.7, p <= 0.01), hepatic margin sharpness (2.4 ± 1,0 vs 1.8 ± 0.7, p <= 0.01). The T1 weighted part of the RAVE-T2/T1 sequence was significantly better than the standard T1 DIXON weighted sequence in three of five image quality categories: respiratory motion artefacts (4.0 ± 0.2 vs 3.6 ± 0.8, p = 0.01), portal vein clarity (2.7 ± 0.9 vs 2.1 ± 0.7, p <= 0.01), hepatic margin sharpness (3.2 ± 0.7 vs 2.6 ± 0.9, p <= 0.01). CONCLUSIONS The RAVE-T2/T1 hybrid sequence is feasible and equal compared to standard T1- and T2-weighted sequences in the assessment of abdominal organs in a pediatric population. Due to non-inferiority to the current standard sequences for abdominal imaging, the RAVE-T2/T1 hybrid sequence is a good alternative for children who cannot be examined in breath-hold technique.
Collapse
Affiliation(s)
- K Glutig
- Jena University Hospital - Friedrich Schiller University Jena, Institute of Diagnostic and Interventional Radiology, Section of Pediatric Radiology, Am Klinikum 1, 07747 Jena, Germany.
| | - H-J Mentzel
- Jena University Hospital - Friedrich Schiller University Jena, Institute of Diagnostic and Interventional Radiology, Section of Pediatric Radiology, Am Klinikum 1, 07747 Jena, Germany
| | - F H Prüfer
- University Children's Hospital UKBB, University of Basel, Paediatric Radiology, Spitalstrasse 33, 4031 Basel, Switzerland
| | - U Teichgräber
- Jena University Hospital - Friedrich Schiller University Jena, Institute of Diagnostic and Interventional Radiology, Section of Pediatric Radiology, Am Klinikum 1, 07747 Jena, Germany
| | - M M Obmann
- University Hospital Basel USB, University of Basel, Clinic of Radiology and Nuclear Medicine, Petersgraben 4, 4031 Basel, Switzerland
| | - M Krämer
- Jena University Hospital - Friedrich Schiller University Jena, Institute of Diagnostic and Interventional Radiology, Section of Pediatric Radiology, Am Klinikum 1, 07747 Jena, Germany
| |
Collapse
|
3
|
Casciani E, Nardo GD, Chin S, Masselli G, Polettini E, Oliva S, Cozzi DA, Cucchiara S, Gualdi G. MR Enterography in paediatric patients with obscure gastrointestinal bleeding. Eur J Radiol 2017; 93:209-216. [PMID: 28668417 DOI: 10.1016/j.ejrad.2017.05.044] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2017] [Revised: 04/17/2017] [Accepted: 05/31/2017] [Indexed: 12/22/2022]
|
4
|
Abstract
To date, there have been many advances in inflammatory bowel disease (IBD) imaging in every cross-sectional imaging modality, particularly in children. The main emphasis in pediatric IBD imaging is on robust and reproducible measures of small bowel Crohn's disease inflammation, accurate diagnosis of IBD-related complications, and minimizing radiation burden to the patient, as repeat imaging is necessary over the course of their disease. In this article, we discuss the current state-of-the-art imaging techniques, in addition to routine fluoroscopy, including MR and CT enterography and bowel ultrasound. We also present the emerging use of new methods to characterize disease severity and distinguish active inflammation from fibrosis such as diffusion-weighted imaging, bowel elastography, and contrast-enhanced ultrasound. The diagnostic performance of particular examinations, their strengths and weaknesses, and role in IBD management will be discussed. Although these advanced imaging techniques applied to children are similar to those performed in adults, special considerations related to their application in pediatric patients will also be reviewed.
Collapse
|
5
|
Magnetic Resonance Enterography Healing and Magnetic Resonance Enterography Remission Predicts Improved Outcome in Pediatric Crohn Disease. J Pediatr Gastroenterol Nutr 2016; 62:378-83. [PMID: 26348683 DOI: 10.1097/mpg.0000000000000976] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
BACKGROUND Mucosal healing predicts clinical remission and improved outcomes in patients with Crohn disease (CD). Magnetic resonance enterography (MRE) is a noninvasive imaging modality that can assess small and large bowel wall inflammation. Evidence suggests that MRE may be an acceptable alternative to evaluate mucosal healing over endoscopy. Our objective is to determine whether MRE remission predicts clinical remission at follow-up in children with CD. METHODS We performed an institutional review board-approved retrospecitve chart review using our prospectively maintained MRE CD database. Inclusion criteria were all children who underwent an MRE more than 6 months after diagnosis with CD who had follow-up of at least 1 year from imaging. RESULTS A total of 101 children with CD underwent MRE, a median of 1.3 years from diagnosis with a median follow-up of 2.8 years after MRE. Active inflammation was detected in 65 MRE studies, whereas 36 MRE studies demonstrated MRE remission. A total of 88.9% of children demonstrating MRE remission were in clinical remission at follow-up, whereas only 44.6% of those demonstrating MRE active inflammation achieved clinical remission. Children demonstrating MRE-active inflammation were more likely to have a change in medication (44.6% vs 8.3%) and more likely to undergo surgery (18.5% vs 2.8%). CONCLUSIONS MRE remission is associated with clinical remission at follow-up at least 1 year after MRE. MRE remission was associated with fewer medication changes and fewer surgeries suggesting that, similar to endoscopic remission, MRE remission demonstrates improved outcome. Additional research is needed to confirm that MRE can be used as a surrogate for mucosal healing.
Collapse
|
6
|
Ognibene NMG, Basile M, Di Maurizio M, Petrillo G, De Filippi C. Features and perspectives of MR enterography for pediatric Crohn disease assessment. Radiol Med 2016; 121:362-77. [PMID: 26838591 DOI: 10.1007/s11547-015-0613-2] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2015] [Accepted: 12/01/2015] [Indexed: 02/07/2023]
Abstract
The aim of this paper is to provide indications for performing magnetic resonance enterography (MRE) in Crohn's disease (CD), the essential technical elements of MRE techniques and typical findings in patients with CD. Patients suffering from CD frequently require cross-sectional imaging. By performing MRE, it is possible to obtain results comparable to those obtained with endoscopy in terms of identifying and assessing disease activity and better than other cross-sectional imaging techniques, such as CT, in the evaluation of the fibrosis and complications of disease. The MR imaging of diffusion MR is a technique which enables medical staff to add important additional information and which may replace the use of intravenous contrast agents in the near future. Magnetic resonance enterography is an accurate tool for assessing bowel disease and the various complications associated with CD. The lack of exposure to non-ionizing radiation is an important advantage of this imaging technique, especially in the case of pediatric patients. Familiarity with common and pathognomonic imaging features of CD is essential for every clinician involved in the treatment of inflammatory bowel disease and the care of patients.
Collapse
Affiliation(s)
- Noemi Maria Giovanna Ognibene
- Radiodiagnostic and Oncological Radiotherapy Unit, University Hospital "Policlinico-Vittorio Emanuele", Catania, Italy
| | - Massimo Basile
- Pediatric Radiology, Meyer Children's University Hospital, Florence, Italy
| | - Marco Di Maurizio
- Pediatric Radiology, Meyer Children's University Hospital, Florence, Italy
| | - Giuseppe Petrillo
- Radiodiagnostic and Oncological Radiotherapy Unit, University Hospital "Policlinico-Vittorio Emanuele", Catania, Italy
| | - Claudio De Filippi
- Pediatric Radiology, Meyer Children's University Hospital, Florence, Italy.
| |
Collapse
|
7
|
MRI for Crohn's Disease: Present and Future. BIOMED RESEARCH INTERNATIONAL 2015; 2015:786802. [PMID: 26413543 PMCID: PMC4564596 DOI: 10.1155/2015/786802] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 08/18/2014] [Revised: 10/09/2014] [Accepted: 12/11/2014] [Indexed: 12/18/2022]
Abstract
Crohn's disease (CD) is a chronic inflammatory condition with relapsing-remitting behavior, often causing strictures or penetrating bowel damage. Its lifelong clinical course necessitates frequent assessment of disease activity and complications. Computed tomography (CT) enterography has been used as primary imaging modality; however, the concern for radiation hazard limits its use especially in younger population. Magnetic resonance (MR) imaging has advantages of avoiding radiation exposure, lower incidence of adverse events, ability to obtain dynamic information, and good soft-tissue resolution. MR enterography (MRE) with oral contrast agent has been used as primary MR imaging modality of CD with high sensitivity, specificity, and interobserver agreement. The extent of inflammation as well as transmural ulcers and fibrostenotic diseases can be detected with MRE. Novel MR techniques such as diffusion-weighted MRI (DWI), motility study, PET-MRI, and molecular imaging are currently investigated for further improvement of diagnosis and management of CD. MR spectroscopy is a remarkable molecular imaging tool to analyze metabolic profile of CD with human samples such as plasma, urine, or feces, as well as colonic mucosa itself.
Collapse
|
8
|
|
9
|
Perianal disease in pediatric Crohn disease: a review of MRI findings. Pediatr Radiol 2014; 44:1198-208; quiz 1195-7. [PMID: 25246189 DOI: 10.1007/s00247-014-3085-y] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/17/2013] [Revised: 05/07/2014] [Accepted: 06/12/2014] [Indexed: 12/18/2022]
Abstract
Perianal complications of Crohn disease are a common occurrence in children and can result in significant morbidity when not accurately characterized prior to surgical intervention. MRI is an excellent imaging modality for the evaluation of perianal inflammatory bowel disease - allowing characterization and detailed description of perianal fistulas. MRI has many advantages over other imaging modalities for the pediatric patient. Radiologists will benefit from a sophisticated understanding of perianal anatomy, the classification of perianal fistulas, the advantages MRI offers in characterization of perianal fistulas as well as the common and incidental findings that are important in the MRI evaluation of perianal inflammatory bowel disease in children. Perianal fistulas are found at a high rate in pediatric referrals and are more commonly found in male patients.
Collapse
|
10
|
Casciani E, Vincentiis CD, Polettini E, Masselli G, Nardo GD, Civitelli F, Cucchiara S, Gualdi GF. Imaging of the small bowel: Crohn’s disease in paediatric patients. World J Radiol 2014; 6:313-328. [PMID: 24976933 PMCID: PMC4072817 DOI: 10.4329/wjr.v6.i6.313] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/27/2013] [Accepted: 05/16/2014] [Indexed: 02/06/2023] Open
Abstract
In more than 20% of all patients, the Crohn’s disease presents before the age of 18years. The diagnosis and management of Crohn’s disease in children has changed dramatically over the last decade, mainly due to increased awareness, availability of newer diagnostic modalities such as magnetic resonance imaging (MRI) and newer, more powerful treatments such as biologics. Imaging of the small bowel is needed for diagnosis, management, follow-up and also evaluation of the disease in terms of location, extent, activity and complications. We review all the methods (barium examinations, ultrasonography, computed tomography, MR, and computed tomography- positron emission tomography) commonly used for imaging the small bowel in paediatric patients with Crohn’s disease analyzing the advantages and disadvantages of each modality, with particular emphasis on MR imaging.
Collapse
|
11
|
Mentzel HJ, Reinsch S, Kurzai M, Stenzel M. Magnetic resonance imaging in children and adolescents with chronic inflammatory bowel disease. World J Gastroenterol 2014; 20:1180-1191. [PMID: 24574794 PMCID: PMC3921502 DOI: 10.3748/wjg.v20.i5.1180] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/16/2013] [Accepted: 01/05/2014] [Indexed: 02/06/2023] Open
Abstract
Inflammatory bowel diseases (IBD) represent challenges, both from a diagnostic, and therapeutic point of view. Deep-seated anatomic structures are difficult to assess by ultrasound technique alone. As radiation-free alternative cross-sectional imaging method, magnetic resonance imaging of the intestinal structures is costly and time-consuming. Examination of pediatric patients imply additional considerations: reduction of body motions in younger children and consideration of the most appropriate preparation, and examination technique. The demanding Sellink technique is the only means for appropriately distending the lesser intestine in order to detect small bowel strictures. Oral intake of contrast medium (CM) alone shows its limitations regarding distensibility. The need for intravenous contrast media application needs to be considered, too. Active inflammation of both intestinal wall, and mesentery can be demonstrated accurately. Nevertheless, viable alternatives to CM application is desirable, considering non-negligible adverse reactions. Recent data suggest diffusion weighted imaging might fill this diagnostic gap. Irrespective of sequence technique chosen, bowel movement remains a major obstacle. Antispasmolytics in their function as smooth muscle relaxants help in improving image quality, however, their use in children might be off-label. Optimal preparation for the examination and appropriate imaging technique allow for diagnosing typical patterns of changes in IBD, such as bowel wall thickening, ulcers, mural stratification, strictures, creeping fat, and comb sign, and lymphadenopathy. The article gives a detailed overview of current significance of magnetic resonance imaging pediatric patients suffering from IBD, considering indications, limitations, and safety aspects.
Collapse
|
12
|
Yacoub JH, Oto A. New Magnetic Resonance Imaging Modalities for Crohn Disease. Magn Reson Imaging Clin N Am 2014; 22:35-50. [DOI: 10.1016/j.mric.2013.07.005] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
|
13
|
Yacoub JH, Obara P, Oto A. Evolving role of MRI in Crohn's disease. J Magn Reson Imaging 2014; 37:1277-89. [PMID: 23712842 DOI: 10.1002/jmri.24081] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2012] [Accepted: 01/22/2013] [Indexed: 12/18/2022] Open
Abstract
MR enterography is playing an evolving role in the evaluation of small bowel Crohn's disease (CD). Standard MR enterography includes a combination of rapidly acquired T2 sequence, balanced steady-state acquisition, and contrast enhanced T1-weighted gradient echo sequence. The diagnostic performance of these sequences has been shown to be comparable, and in some respects superior, to other small bowel imaging modalities. The findings of CD on MR enterography have been well described in the literature. New and emerging techniques such as diffusion-weighted imaging (DWI), dynamic contrast enhanced MRI (DCE-MRI), cinematography, and magnetization transfer, may lead to improved accuracy in characterizing the disease. These advanced techniques can provide quantitative parameters that may prove to be useful in assessing disease activity, severity, and response to treatment. In the future, MR enterography may play an increasing role in management decisions for patients with small bowel CD; however, larger studies are needed to validate these emerging MRI parameters as imaging biomarkers.
Collapse
Affiliation(s)
- Joseph H Yacoub
- Department of Radiology, University of Chicago, Chicago, Illinois 60637, USA
| | | | | |
Collapse
|
14
|
Fiorino G, Bonifacio C, Padrenostro M, Sposta FM, Spinelli A, Malesci A, Balzarini L, Peyrin-Biroulet L, Danese S. Comparison between 1.5 and 3.0 Tesla magnetic resonance enterography for the assessment of disease activity and complications in ileo-colonic Crohn's disease. Dig Dis Sci 2013; 58:3246-55. [PMID: 23903867 DOI: 10.1007/s10620-013-2781-z] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/28/2013] [Accepted: 06/25/2013] [Indexed: 12/22/2022]
Abstract
BACKGROUND Magnetic resonance imaging (MRI) can assess disease activity and severity in Crohn's disease (CD). Three-Tesla magnetic resonance (3T) increases signal-to-noise ratio (SNR) and reduces time of image acquisition (IAT). Whether 3T increases the accuracy of MRI in CD compared to 1.5T is unknown. AIM We aimed to compare prospectively the accuracy of 3 and 1.5T in ileo-colonic CD patients. METHODS Twenty-six patients with ileo-colonic CD underwent 1.5 and 3T MR enterography at the same time. Ileocolonoscopy was the reference standard for luminal disease. Sensitivity, specificity and accuracy of MRI in evaluating six signs of active and complicated disease (localization, thickening, enhancement, strictures, entero-enteric fistulas, and ulcers) were calculated for both techniques. RESULTS Three-Tesla resulted as sensitive, specific, and accurate as 1.5T in detecting disease location (accuracy 0.93 vs. 0.86), bowel wall thickening and enhancement (accuracy 0.92 vs. 0.80 for both parameters), strictures (accuracy 0.90 vs. 0.80) and entero-enteric fistulas (accuracy 0.92 vs. 0.92). 3T was superior to 1.5T in detecting ulcers (0.76 vs. 0.42, P < 0.05). SNR resulted higher in 3T, and IAT resulted shorter than 1.5. CONCLUSIONS We found that 3T is equally accurate as 1.5T in evaluating ileo-colonic CD. Because of superiority in detecting mucosal ulcers, 3T should be preferred in patients with ileo-colonic CD.
Collapse
Affiliation(s)
- Gionata Fiorino
- IBD Center, Gastroenterology, IRCCS Humanitas, Via Manzoni 56, 20089, Rozzano, Milan, Italy
| | | | | | | | | | | | | | | | | |
Collapse
|
15
|
Diagnosis and treatment of perianal Crohn disease: NASPGHAN clinical report and consensus statement. J Pediatr Gastroenterol Nutr 2013; 57:401-12. [PMID: 23974063 DOI: 10.1097/mpg.0b013e3182a025ee] [Citation(s) in RCA: 99] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Inflammatory bowel disease is a chronic inflammatory disorder of the gastrointestinal tract that includes both Crohn disease (CD) and ulcerative colitis. Abdominal pain, rectal bleeding, diarrhea, and weight loss characterize both CD and ulcerative colitis. The incidence of IBD in the United States is 70 to 150 cases per 100,000 individuals and, as with other autoimmune diseases, is on the rise. CD can affect any part of the gastrointestinal tract from the mouth to the anus and frequently will include perianal disease. The first description connecting regional enteritis with perianal disease was by Bissell et al in 1934, and since that time perianal disease has become a recognized entity and an important consideration in the diagnosis and treatment of CD. Perianal Crohn disease (PCD) is defined as inflammation at or near the anus, including tags, fissures, fistulae, abscesses, or stenosis. The symptoms of PCD include pain, itching, bleeding, purulent discharge, and incontinence of stool. In this report, we review and discuss the etiology, diagnosis, evaluation, and treatment of PCD.
Collapse
|
16
|
Abstract
This article addresses the current technique and protocols for magnetic resonance (MR) enterography, with a primary focus on inflammatory bowel disease (IBD) and a secondary detailed discussion of other diseases of the small bowel beyond IBD. A brief discussion of MR imaging for appendicitis is included, but the evaluation of appendicitis does not require an enterographic protocol. The focused key points and approach presented in this article are intended to enhance the reader's understanding to help improve patient compliance with the MR enterographic studies, overcome challenges, and improve interpretation.
Collapse
|
17
|
Hammer MR, Podberesky DJ, Dillman JR. Multidetector Computed Tomographic and Magnetic Resonance Enterography in Children. Radiol Clin North Am 2013; 51:615-36. [DOI: 10.1016/j.rcl.2013.04.001] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
18
|
Giles E, Barclay AR, Chippington S, Wilson DC. Systematic review: MRI enterography for assessment of small bowel involvement in paediatric Crohn's disease. Aliment Pharmacol Ther 2013; 37:1121-31. [PMID: 23638954 DOI: 10.1111/apt.12323] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/11/2012] [Revised: 12/31/2012] [Accepted: 04/07/2013] [Indexed: 12/15/2022]
Abstract
BACKGROUND Barium meal enteroclysis (BM) is the recommended imaging technique for small bowel inaccessible by ileo-colonoscopy when diagnosing paediatric-onset inflammatory bowel disease, but it has poor sensitivity and involves ionising radiation. MRI enterography (MRE) is an alternative methodology. AIMS To critically appraise the published evidence on MRE in the assessment of Paediatric inflammatory bowel disease by systematic review. METHODS Review of all English language data reporting MRE for the investigation of patients <18 years with known or suspected IBD. Primary searches of Medline (Jan 1950-April 2012), Cinahl (1966-April 2012) and Pubmed (Jan 1950-April 2012) were performed using keyword and MeSH terms; IBD; Magnetic resonance imaging; small bowel imaging; EMBASE was then searched. Two authors independently assessed the quality of studies using the quality assessment of diagnostic accuracy studies tool. RESULTS Searches yielded 930 035 hits, combination word searches limited to 1983 titles. Fifty-two studies were fully reviewed, 41 were excluded due to lack of paediatric data. Eleven studies of 496 children were included. All studies used endoscopy as the reference test. 10/496 patients required jejunal intubation for bowel preparation. Meta-analysis of six comparable studies gave a pooled sensitivity and specificity for MRE detection of active terminal ileal Crohn's disease of 84% and 97% respectively. Studies displayed heterogeneity in bowel preparation, scanning technique, reporting methodology and timing of ileo-colonoscopy in relation to MRE. In three studies comparing BM, MRE had greater sensitivity and specificity. CONCLUSIONS MRE is a sensitive and specific tool for diagnosis in paediatric inflammatory bowel disease. Technical considerations require refinement and standardisation; however, MRE has no radiation. Current data suggest that MRE should supersede BM as the SB imaging technique in centres with appropriate expertise.
Collapse
Affiliation(s)
- E Giles
- Paediatric Gastroenterology, Barts and the London School of Medicine and Dentistry, London, UK
| | | | | | | |
Collapse
|
19
|
Di Nardo G, Aloi M, Oliva S, Civitelli F, Casciani E, Cucchiara S. Investigation of small bowel in pediatric Crohn's disease. Inflamm Bowel Dis 2012; 18:1760-76. [PMID: 22275336 DOI: 10.1002/ibd.22885] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/10/2011] [Accepted: 12/28/2011] [Indexed: 12/16/2022]
Abstract
Investigation of the small bowel has been traditionally a challenge for pediatric gastroenterologists due to its location, anatomical tortuosity, and invasiveness of the available techniques. Recently, there has been a remarkable improvement in imaging and endoscopic tools aimed at exploring successfully the small intestine in inflammatory bowel disease. The former are represented by ultrasonography (either alone or with administration of oral contrast agents) and by magnetic resonance: both have provided accurate methods to detect structural bowel changes, diminishing patient discomfort and precluding radiation hazard. The use of traditional radiologic techniques such as fluoroscopy have been markedly reduced due to radiation exposure and inability to depict transmural inflammation or extraluminal complications. Among the novel endoscopic tools, capsule endoscopy and balloon-assisted enteroscopy have tremendously opened new diagnostic and therapeutic perspectives, by allowing the direct visualization of small intestinal mucosa and, through enteroscopy, histological diagnosis as well as therapeutic interventions such as stricture dilation and bleeding treatment. These endoscopic techniques should always be preceded by imaging of the intestine in order to identify strictures. This review describes the most recent progress with the employment of novel imaging and endoscopic methodologies for investigating the small bowel in children with suspected or established Crohn's disease.
Collapse
Affiliation(s)
- Giovanni Di Nardo
- Department od Pediatrics and Infantile Neuropsychiatry, Pediatric Gastroenterology and Liver Unit, Sapienza University of Rome, University Hospital Umberto I, Rome, Italy
| | | | | | | | | | | |
Collapse
|
20
|
Comparison of magnetic resonance enterography with endoscopy, histopathology, and laboratory evaluation in pediatric Crohn disease. J Pediatr Gastroenterol Nutr 2012; 55:178-84. [PMID: 22513710 DOI: 10.1097/mpg.0b013e3182598465] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
BACKGROUND AND OBJECTIVE Children with Crohn disease (CD) often undergo cross-sectional imaging during clinical evaluation. Magnetic resonance enterography (MRE) is becoming the preferred radiologic assessment due to the lack of radiation exposure; however, there are few data in children with CD comparing MRE with objective disease measures. The aim of the present study was to compare MRE with endoscopy, histopathology, and laboratory evaluation in children with CD. METHODS We performed an institutional review board-approved query of our prospective CD MRE database, which includes data in children with CD undergoing MRE since 2008. RESULTS A total of 147 MRE studies were performed in 119 different children with symptomatic CD. Of those, 53 (39.6%) MRE studies were performed at diagnosis to evaluate small bowel disease burden. A total of 117 (79.6%) MRE studies displayed active and/or chronic disease, whereas 30 (20.4%) MRE studies were normal. When compared with normal MRE studies, active inflammation on MRE was associated with a higher mean C-reactive protein (3.6 vs 1.1, P < 0.001), higher erythrocyte sedimentation rate (36 vs 22, P = 0.0.31), higher platelet value (439 vs 352, P = 0.033), and lower albumin (3.4 vs 3.7, P = 0.049). Comparison between MRE and endoscopy demonstrated excellent agreement when ulcers were present, and moderate agreement with histopathology. CONCLUSIONS Active inflammation on MRE is associated with higher C-reactive protein, erythrocyte sedimentation rate, platelets, and lower albumin in children with CD. MRE displays excellent agreement with endoscopic disease described by ulcers but poor agreement with mild mucosal disease described by erythema and friability. The present study adds to a growing body of evidence that MRE provides excellent assessment of inflammation and measures disease activity in CD.
Collapse
|
21
|
Abstract
OBJECTIVES The present UK criterion standard for assessing children with suspected inflammatory bowel disease (IBD) is upper endoscopy, ileocolonoscopy, and barium follow-through (BaFT). Significant doses of radiation, unpalatable contrast, and volume intolerance are involved with BaFT. Practice in investigating Crohn disease (CD) is changing with the increasing use of magnetic resonance imaging (MRI). The aim of the present study was to compare BaFT and a new abdominal MRI protocol in a paediatric IBD population. METHODS All consecutive patients with a new diagnosis of IBD or requiring reassessment from September 2008 to December 2010 were investigated with both abdominal MRI and BaFT in accordance with a specific local paediatric IBD protocol. The studies were reported by nonblinded radiologists with an interest in gastrointestinal imaging. The reports were compared in conjunction with case note review. RESULTS Eighty-seven patients underwent both BaFT and MRI abdomen. Thirty-one percent of patients had additional pathology on MRI, not seen on the BaFT. Sixty-seven percent of patients (n=59) had an MRI finding equivalent to BaFT. Using histology as a criterion standard for detecting terminal ileal disease, BaFT had a sensitivity and specificity of 76% and 67%, and MRI had a sensitivity and specificity of 83% and 95%, respectively. CONCLUSIONS This is the largest series of small bowel MRI in a paediatric population. MRI reports were at least equivalent to BaFT. MRI had higher sensitivity and, particularly, specificity in detecting terminal ileal pathology. These findings suggest that MRI should become the criterion standard investigation in children with IBD in centres with appropriate expertise, with zero radiation exposure being highly advantageous.
Collapse
|
22
|
Anupindi SA, Janitz E, Darge K. Bowel Imaging in Children: A Comprehensive Look Using US and MRI. Semin Roentgenol 2012; 47:118-26. [DOI: 10.1053/j.ro.2011.11.003] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
|
23
|
Herrmann KA, Paspulati RM, Lauenstein T, Reiser MF. Benefits and challenges in bowel MR imaging at 3.0 T. Top Magn Reson Imaging 2010; 21:165-175. [PMID: 21847036 DOI: 10.1097/rmr.0b013e31822a3294] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Abdominal imaging at 3.0 T has shown to be challenging because of a number of artifacts and effects related to the physics at higher field strength. For bowel imaging at 3.0 T, artifacts due to magnetic field inhomogeneities, standing waves, increased susceptibility, and greater chemical shift effects are of particular concern because they are likely to affect the assessment of relevant structures and counterbalance the benefits of higher signal-to-noise ratio. Regarding small- and large-bowel magnetic resonance imaging, the benefits of higher field strengths translate mainly in better contrast-to-noise ratio of contrast-enhanced T1-weighted gradient echo and T2-weighted imaging, whereas steady-state free precession sequences seem to suffer from serious degradation of image quality. The present article summarizes the technical challenges in bowel imaging at 3.0 T, provides an overview of performance compared with 1.5 T in small- and large-bowel diseases including the rectum, and revises the current literature.
Collapse
Affiliation(s)
- Karin A Herrmann
- Institute of Clinical Radiology, Ludwig-Maximilians-University Munich, University Hospitals Munich, Munich, Germany.
| | | | | | | |
Collapse
|