OBJECTIVE
To evaluate the accuracy of semiautomated segmentation of urinary stone size in computed tomography (CT) compared with manual measurement.
MATERIALS AND METHODS
A total of 103 patients (32f, 71m ; mean age 52 years±18 that were diagnosed with urolithiasis and collected stones received standardized ex vivo CT-scans and radiography of the stones. Stone size was segmented semiautomatically using commercial software (syngo.via, Siemens, Germany) and compared with manual caliper measurement on digital radiography.
RESULTS
Mean size was 4.4 mm in CT and 4.6 mm in radiography. Depending on number of stones analyzed per patient, estimation of stone size showed moderate to excellent correlation for both methods. There was no significant difference in overall size measurement.
CONCLUSION
Semiautomatic segmentation of urinary stone size in CT is possible and reduces measurement errors, allowing more precise estimation especially for smaller concrements. Neighboring stones may hamper segmentation of stone size.