1
|
Taillefer R. Scintillation cameras: A new clinical era has come. J Nucl Cardiol 2022; 29:1942-1945. [PMID: 34254249 DOI: 10.1007/s12350-021-02660-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2021] [Accepted: 04/09/2021] [Indexed: 12/22/2022]
Affiliation(s)
- Raymond Taillefer
- Department of Nuclear Medicine, Hôpital du Haut-Richelieu, CISSS de la Montérégie Centre, 920 Boulevard du Séminaire Nord, Saint-Jean-sur-Richelieu, Quebec, J3A 1B7, Canada.
| |
Collapse
|
2
|
Azarine A, Scalbert F, Garçon P. Cardiac functional imaging. Presse Med 2022; 51:104119. [PMID: 35321846 DOI: 10.1016/j.lpm.2022.104119] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/03/2021] [Revised: 01/27/2022] [Accepted: 03/11/2022] [Indexed: 01/01/2023] Open
Abstract
During the last 20 years, cardiac imaging has drastically evolved. Positron emission tomography (PET), fast three-dimensional (3D) imaging with the latest generations of echocardiography & multi-detector computed tomography (CT), stress perfusion assessed by magnetic resonance imaging (MRI), blood flow analysis using four-dimensional (4D) flow MRI, all these techniques offer new trends for optimal noninvasive functional cardiac imaging. Dynamic functional imaging is obtained by acquiring images of the heart at different phases of the cardiac cycle, allowing assessment of cardiac motion, function, and perfusion. Between CT and Cardiac MRI (CMR), CMR has the best temporal resolution, which is suitable for functional imaging while cardiac CT provides higher spatial resolution with isotropic data that have an identical resolution in the three dimensions of the space. The latest generations of CT scanners enable whole heart assessment in one beat, offering also an acceptable temporal resolution with the possibility to display the images in a dynamic mode. Another rapidly growing technique using functional and molecular imaging for the assessment of biological and metabolic pathways is the PET using radio-labeled tracers. Meanwhile, the oldest cardiac imaging tool with doppler ultrasound technology has never stopped evolving. Echocardiography today performs 3D imaging, stress perfusion, and myocardial strain assessment, with high temporal resolution. It still is the first line and more accessible exam for the patient. These different modalities are complementary and may be even combined into PET-CT or PET-MRI. The ability to combine the functional/molecular data with anatomical images may implement a new dimension to our diagnostic tools.
Collapse
Affiliation(s)
- Arshid Azarine
- Radiology Department, Groupe Hospitalier Paris Saint-Joseph, 185, Rue Raymond Losserand, 75014, Paris, France.
| | - François Scalbert
- Nuclear Medecine Department, Hôpital Bichat-Claude Bernard, 46 rue Henri Huchard, 75877, Paris, France
| | - Philippe Garçon
- Cardiology Department, Groupe Hospitalier Paris Saint-Joseph, 185, Rue Raymond Losserand, 75014, Paris, France
| |
Collapse
|
3
|
Cantoni V, Green R, Ricciardi C, Assante R, Zampella E, Nappi C, Gaudieri V, Mannarino T, Genova A, De Simini G, Giordano A, D'Antonio A, Acampa W, Petretta M, Cuocolo A. A machine learning-based approach to directly compare the diagnostic accuracy of myocardial perfusion imaging by conventional and cadmium-zinc telluride SPECT. J Nucl Cardiol 2022; 29:46-55. [PMID: 32424676 DOI: 10.1007/s12350-020-02187-0] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2020] [Accepted: 04/29/2020] [Indexed: 01/18/2023]
Abstract
BACKGROUND We evaluated the performance of conventional (C) single-photon emission computed tomography (SPECT) and cadmium-zinc-telluride (CZT)-SPECT in a large cohort of patients with suspected or known coronary artery disease (CAD) and compared the diagnostic accuracy of the two systems using machine learning (ML) algorithms. METHODS AND RESULTS A total of 517 consecutive patients underwent stress myocardial perfusion imaging (MPI) by both C-SPECT and CZT-SPECT. In the overall population, an excellent correlation between stress MPI data and left ventricular (LV) functional parameters measured by C-SPECT and by CZT-SPECT was observed (all P < .001). ML analysis performed through the implementation of random forest (RF) and k-nearest neighbors (NN) algorithms proved that CZT-SPECT has greater accuracy than C-SPECT in detecting CAD. For both algorithms, the sensitivity of CZT-SPECT (96% for RF and 60% for k-NN) was greater than that of C-SPECT (88% for RF and 53% for k-NN). CONCLUSIONS MPI data and LV functional parameters obtained by CZT-SPECT are highly reproducible and provide good correlation with those obtained by C-SPECT. ML approach showed that the accuracy and sensitivity of CZT-SPECT is greater than C-SPECT in detecting CAD.
Collapse
Affiliation(s)
- Valeria Cantoni
- Department of Advanced Biomedical Sciences, University Federico II, Via Pansini 5, 80131, Naples, Italy
| | - Roberta Green
- Department of Advanced Biomedical Sciences, University Federico II, Via Pansini 5, 80131, Naples, Italy
| | - Carlo Ricciardi
- Department of Advanced Biomedical Sciences, University Federico II, Via Pansini 5, 80131, Naples, Italy
| | - Roberta Assante
- Department of Advanced Biomedical Sciences, University Federico II, Via Pansini 5, 80131, Naples, Italy
| | - Emilia Zampella
- Department of Advanced Biomedical Sciences, University Federico II, Via Pansini 5, 80131, Naples, Italy
| | - Carmela Nappi
- Department of Advanced Biomedical Sciences, University Federico II, Via Pansini 5, 80131, Naples, Italy
| | - Valeria Gaudieri
- Department of Advanced Biomedical Sciences, University Federico II, Via Pansini 5, 80131, Naples, Italy
| | - Teresa Mannarino
- Department of Advanced Biomedical Sciences, University Federico II, Via Pansini 5, 80131, Naples, Italy
| | - Andrea Genova
- Department of Advanced Biomedical Sciences, University Federico II, Via Pansini 5, 80131, Naples, Italy
| | - Giovanni De Simini
- Department of Advanced Biomedical Sciences, University Federico II, Via Pansini 5, 80131, Naples, Italy
| | - Alessia Giordano
- Department of Advanced Biomedical Sciences, University Federico II, Via Pansini 5, 80131, Naples, Italy
| | - Adriana D'Antonio
- Department of Advanced Biomedical Sciences, University Federico II, Via Pansini 5, 80131, Naples, Italy
| | - Wanda Acampa
- Department of Advanced Biomedical Sciences, University Federico II, Via Pansini 5, 80131, Naples, Italy
- Institute of Biostructure and Bioimaging, National Council of Research, Naples, Italy
| | - Mario Petretta
- Department of Translational Medical Sciences, University Federico II, Naples, Italy
| | - Alberto Cuocolo
- Department of Advanced Biomedical Sciences, University Federico II, Via Pansini 5, 80131, Naples, Italy.
| |
Collapse
|
4
|
|
5
|
Liu L, Abdu FA, Yin G, Xu B, Mohammed AQ, Xu S, Lv X, Luo Y, Zu L, Yang C, Zhang Z, Zhou Y, Cai H, Lv Z, Xu Y, Che W. Prognostic value of myocardial perfusion imaging with D-SPECT camera in patients with ischemia and no obstructive coronary artery disease (INOCA). J Nucl Cardiol 2021; 28:3025-3037. [PMID: 33000403 DOI: 10.1007/s12350-020-02252-8] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2019] [Accepted: 06/01/2020] [Indexed: 12/21/2022]
Abstract
BACKGROUND Myocardial perfusion imaging (MPI) with a novel D-SPECT camera maintains excellent prognostic value compared to conventional SPECT. However, information about the relationship between D-SPECT MPI and the prognosis in patients with ischemia and no obstructive coronary artery disease (INOCA) is limited. The objective of this study was to evaluate the prognostic value of MPI with D-SPECT in INOCA and obstructive coronary artery disease (CAD) patients. METHODS All consecutive patients with suspected CAD and without prior CAD who underwent D-SPECT MPI and invasive coronary angiography within 3 months were considered. INOCA and obstructive CAD were defined as < 50% and ≥ 50% coronary stenosis, respectively. Patients were followed-up for the occurrence of major adverse cardiac events (MACE: cardiovascular death, nonfatal myocardial infarction, revascularization, stroke, heart failure and angina-related rehospitalization). RESULTS Among 506 patients, 232 (45.8%) were INOCA patients. A total of 33.2% of the INOCA patients had abnormal D-SPECT MPI, whereas 77.7% of the obstructive CAD patients had abnormal D-SPECT MPI. In both groups, patients with abnormal D-SPECT MPI demonstrated higher MACE rates and lower survival free of MACE. In addition, patients with INOCA and abnormal D-SPECT MPI had a poor prognosis similar to that of the obstructive CAD patients. Cox regression analysis showed that the risk-adjusted hazard ratios for abnormal D-SPECT MPI were 2.55 [1.11-5.87] and 2.06 [1.03-4.10] in the INOCA and obstructive CAD patients, respectively. CONCLUSIONS D-SPECT MPI provides excellent prognostic information, with a more severe prognosis in patients with abnormal D-SPECT MPI. INOCA patients with abnormal D-SPECT MPI experience a poor prognosis similar to that of patients with obstructive CAD.
Collapse
Affiliation(s)
- Lu Liu
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, 301 Yanchang Road, Shanghai, 200072, China
- Department of Cardiology, Clinical Medical College of Shanghai Tenth People's Hospital, Nanjing Medical University, Shanghai, China
| | - Fuad A Abdu
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, 301 Yanchang Road, Shanghai, 200072, China
| | - Guoqing Yin
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, 301 Yanchang Road, Shanghai, 200072, China
- Department of Cardiology, Clinical Medical College of Shanghai Tenth People's Hospital, Nanjing Medical University, Shanghai, China
| | - Bin Xu
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, 301 Yanchang Road, Shanghai, 200072, China
| | - Abdul-Quddus Mohammed
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, 301 Yanchang Road, Shanghai, 200072, China
| | - Siling Xu
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, 301 Yanchang Road, Shanghai, 200072, China
| | - Xian Lv
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, 301 Yanchang Road, Shanghai, 200072, China
| | - Yanru Luo
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, 301 Yanchang Road, Shanghai, 200072, China
| | - Lu Zu
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, 301 Yanchang Road, Shanghai, 200072, China
| | - Changrui Yang
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, 301 Yanchang Road, Shanghai, 200072, China
| | - Ziyi Zhang
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, 301 Yanchang Road, Shanghai, 200072, China
| | - Yuxiao Zhou
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, 301 Yanchang Road, Shanghai, 200072, China
| | - Haidong Cai
- Department of Nuclear Medicine, Shanghai Tenth People's Hospital, Tongji University School of Medicine, 301 Yanchang Road, Shanghai, 200072, China
| | - Zhongwei Lv
- Department of Nuclear Medicine, Shanghai Tenth People's Hospital, Tongji University School of Medicine, 301 Yanchang Road, Shanghai, 200072, China.
| | - Yawei Xu
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, 301 Yanchang Road, Shanghai, 200072, China.
| | - Wenliang Che
- Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, 301 Yanchang Road, Shanghai, 200072, China.
| |
Collapse
|
6
|
Cantoni V, Green R, Acampa W, Zampella E, Assante R, Nappi C, Gaudieri V, Mannarino T, Cuocolo R, Di Vaia E, Petretta M, Cuocolo A. Diagnostic performance of myocardial perfusion imaging with conventional and CZT single-photon emission computed tomography in detecting coronary artery disease: A meta-analysis. J Nucl Cardiol 2021; 28:698-715. [PMID: 31089962 DOI: 10.1007/s12350-019-01747-3] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2019] [Accepted: 04/23/2019] [Indexed: 12/21/2022]
Abstract
BACKGROUND We performed a meta-analysis to compare the diagnostic performance of conventional SPECT (C-SPECT) and cadmium-zinc-telluride (CZT)-SPECT systems in detecting angiographically proven coronary artery disease (CAD). METHODS Studies published between January 2000 and February 2018 were identified by database search. We included studies assessing C-SPECT or CZT-SPECT as a diagnostic test to evaluate patients for the presence of CAD, defined as at least 50% diameter stenosis on invasive coronary angiography. A study was eligible regardless of whether patients were referred for suspected or known CAD. RESULTS We identified 40 eligible articles (25 C-SPECT and 15 CZT-SPECT studies) including 7334 patients (4997 in C-SPECT and 2337 in CZT-SPECT studies). The pooled sensitivity and specificity were 85% and 66% for C-SPECT and 89% and 69% for CZT-SPECT imaging studies. The area under the curve was slightly higher for CZT-SPECT (0.89) compared to C-SPECT (0.83); accordingly, the summary diagnostic OR was 17 for CZT-SPECT and 11 for C-SPECT. The accuracy of the two tests slightly differs between C-SPECT and CZT-SPECT (chi-square 11.28, P < .05). At meta-regression analysis, no significant association between both sensitivity and specificity and demographical and clinical variables considered was found for C-SPECT and CZT-SPECT studies. CONCLUSIONS C-SPECT and CZT-SPECT have good diagnostic performance in detecting angiographic proven CAD, with a slightly higher accuracy for CZT-SPECT. This result supports the use of the novel gamma cameras in clinical routine practices also considering the improvements in acquisition time and radiation exposure reduction.
Collapse
Affiliation(s)
- Valeria Cantoni
- Department of Advanced Biomedical Sciences, University Federico II, Via Pansini 5, 80131, Naples, Italy
| | - Roberta Green
- Department of Advanced Biomedical Sciences, University Federico II, Via Pansini 5, 80131, Naples, Italy
| | - Wanda Acampa
- Department of Advanced Biomedical Sciences, University Federico II, Via Pansini 5, 80131, Naples, Italy
- Institute of Biostructure and Bioimaging, National Council of Research, Naples, Italy
| | - Emilia Zampella
- Department of Advanced Biomedical Sciences, University Federico II, Via Pansini 5, 80131, Naples, Italy
| | - Roberta Assante
- Department of Advanced Biomedical Sciences, University Federico II, Via Pansini 5, 80131, Naples, Italy
| | - Carmela Nappi
- Department of Advanced Biomedical Sciences, University Federico II, Via Pansini 5, 80131, Naples, Italy
| | - Valeria Gaudieri
- Department of Advanced Biomedical Sciences, University Federico II, Via Pansini 5, 80131, Naples, Italy
| | - Teresa Mannarino
- Department of Advanced Biomedical Sciences, University Federico II, Via Pansini 5, 80131, Naples, Italy
| | - Renato Cuocolo
- Department of Advanced Biomedical Sciences, University Federico II, Via Pansini 5, 80131, Naples, Italy
| | - Eugenio Di Vaia
- Department of Advanced Biomedical Sciences, University Federico II, Via Pansini 5, 80131, Naples, Italy
| | - Mario Petretta
- Department of Translational Medical Sciences, University Federico II, Naples, Italy
| | - Alberto Cuocolo
- Department of Advanced Biomedical Sciences, University Federico II, Via Pansini 5, 80131, Naples, Italy.
| |
Collapse
|
7
|
Yamada Y, Nakano S, Gatate Y, Okano N, Muramatsu T, Nishimura S, Kuji I, Fukushima K, Matsunari I. Feasibility of simultaneous 99mTc-tetrofosmin and 123I-BMIPP dual-tracer imaging with cadmium-zinc-telluride detectors in patients undergoing primary coronary intervention for acute myocardial infarction. J Nucl Cardiol 2021; 28:187-195. [PMID: 30603890 DOI: 10.1007/s12350-018-01585-9] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2018] [Accepted: 12/17/2018] [Indexed: 11/25/2022]
Abstract
BACKGROUND Simultaneous dual-tracer imaging using isotopes with close photo-peaks may benefit from improved properties of cadmium-zinc-telluride (CZT)-based scanners. METHODS Thirty patients having undergone primary percutaneous coronary intervention for acute myocardial infarction underwent single-(99mTc-tetrofosmin (TF) or 123I-BMIPP first) followed by simultaneous 99mTc-TF /123I-BMIPP dual-tracer imaging using a Discovery NM/CT 670 CZT. The values for the quantitative gated-SPECT (QGS) and the quantitative perfusion SPECT (QPS) were assessed. RESULTS The intra-class correlation (ICC) coefficients between the single- and dual-tracer imaging were high in all the QGS and QPS data (Summed motion score: 0.95, summed thickening score: 0.94, ejection fraction: 0.98, SRS for 99mTc-TF: 0.97/ for 123I-BMIPP: 0.95). Wall motion, wall thickening and rest scores per coronary-territory-based regions were also comparable between the single- and dual imaging (ICC coefficient > 0.91). The interrater concordance in the visual analysis for the infarction and perfusion-metabolism mismatch was significant for the global and regional left ventricle (P < 0.001). CONCLUSION The quantitative/semi-quantitative values for global and regional left-ventricular function, perfusion, and fatty acid metabolism were closely comparable between the dual-tracer imaging and the single-tracer mode. These data suggests the feasibility of the novel CZT-based scanner for the simultaneous 99mTc-TF /123I-BMIPP dual-tracer acquisitions in clinical settings.
Collapse
Affiliation(s)
- Yoshihiro Yamada
- Department of Cardiology International Medical Center, Saitama Medical University, 1397-1 Yamane Hidaka, Saitama, 350-1298, Japan
| | - Shintaro Nakano
- Department of Cardiology International Medical Center, Saitama Medical University, 1397-1 Yamane Hidaka, Saitama, 350-1298, Japan.
| | - Youdou Gatate
- Department of Cardiology International Medical Center, Saitama Medical University, 1397-1 Yamane Hidaka, Saitama, 350-1298, Japan
| | - Nanami Okano
- Division of Nuclear Medicine, Department of Radiology, Saitama Medical University, Saitama, Japan
| | - Toshihiro Muramatsu
- Department of Cardiology International Medical Center, Saitama Medical University, 1397-1 Yamane Hidaka, Saitama, 350-1298, Japan
| | - Shigeyuki Nishimura
- Department of Cardiology International Medical Center, Saitama Medical University, 1397-1 Yamane Hidaka, Saitama, 350-1298, Japan
| | - Ichiei Kuji
- Department of Nuclear Medicine International Medical Center, Saitama Medical University, Saitama, Japan
| | - Kenji Fukushima
- Department of Nuclear Medicine International Medical Center, Saitama Medical University, Saitama, Japan
| | - Ichiro Matsunari
- Division of Nuclear Medicine, Department of Radiology, Saitama Medical University, Saitama, Japan
| |
Collapse
|
8
|
Shortened acquisition time in simultaneous 99mTc-tetrofosmin and 123I-β-methyl-p-iodophenyl pentadecanoic acid dual-tracer imaging with cadmium-zinc-telluride detectors in patients undergoing primary coronary intervention for acute myocardial infarction. Nucl Med Commun 2020; 40:1130-1137. [PMID: 31524763 DOI: 10.1097/mnm.0000000000001084] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE The use of cadmium-zinc-telluride-based scanners may increase the clinical feasibility of simultaneous dual-isotope imaging. In the current study, we sought to investigate a potential acquisition time in simultaneous Tc-tetrofosmin/I-β-methyl-p-iodophenyl pentadecanoic acid dual-isotope imaging using a Discovery NM/CT 670 cadmium-zinc-telluride. METHODS Simultaneous Tc-tetrofosmin/I-β-methyl-p-iodophenyl pentadecanoic acid dual-isotope imaging was performed in 29 patients who had undergone primary percutaneous coronary intervention for acute myocardial infarction. Referenced images with an acquisition time of 65 s/view (16.25 min) were reframed to produce images with acquisition times of 33, 16, and 8 s/view. The values for the quantitative-gated single-photon emission computed tomography (SPECT) and the quantitative perfusion SPECT were compared. RESULTS The quantitative-gated SPECT values for images with 33, 16, and 8 s/views showed good consistency with those for 65 s/view (the lower 95% confidence intervals for the intraclass correlation were ≥0.80). The quantitative perfusion SPECT values for Tc-tetrofosmin images with 33, 16, and 8 s/views also showed good consistency with those for 65 s/view; however, the quantitative perfusion SPECT values for I-β-methyl-p-iodophenyl pentadecanoic acid images with an acquisition time of 8 s/view were not consistent with the reference acquisition time of 65 s/view. CONCLUSIONS The quantitative-gated SPECT and quantitative perfusion SPECT values obtained from images with shorter acquisition times correlated with the values obtained from images with a reference acquisition time of 65 s/view; however, tracer-specific predisposition should be considered. These findings suggest that it is possible to reduce acquisition time when performing simultaneous Tc-tetrofosmin/I-β-methyl-p-iodophenyl pentadecanoic acid dual-tracer imaging with the novel cadmium-zinc-telluride scanner.
Collapse
|
9
|
Barone-Rochette G, Bruère D, Mansencal N. How to explore coronary artery disease? Arch Cardiovasc Dis 2019; 112:546-549. [PMID: 31331760 DOI: 10.1016/j.acvd.2019.05.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/04/2019] [Revised: 05/19/2019] [Accepted: 05/21/2019] [Indexed: 11/16/2022]
Affiliation(s)
- Gilles Barone-Rochette
- Department of Cardiology, CHU Grenoble-Alpes, 38043 Grenoble, France; Inserm, U1039, Radiopharmaceutiques Biocliniques, Grenoble Alpes University, 38700 La Tronche, France; French Alliance Clinical Trial, French Clinical Research Infrastructure Network, 31059 Toulouse, France.
| | - Didier Bruère
- Centre de Cardiologie Clinique Du Pont De Chaume, 82000 Montauban, France
| | - Nicolas Mansencal
- Service de Cardiologie, CHU Ambroise-Paré, AP-HP, 92104 Boulogne Billancourt, France; Inserm U1018, CESP, Team 5 (EpReC, Renal and Cardiovascular Epidemiology), UVSQ, 94805 Villejuif, France
| |
Collapse
|
10
|
Hyafil F, Gimelli A, Slart RHJA, Georgoulias P, Rischpler C, Lubberink M, Sciagra R, Bucerius J, Agostini D, Verberne HJ. EANM procedural guidelines for myocardial perfusion scintigraphy using cardiac-centered gamma cameras. Eur J Hybrid Imaging 2019; 3:11. [PMID: 34191169 PMCID: PMC8218102 DOI: 10.1186/s41824-019-0058-2] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2019] [Accepted: 06/10/2019] [Indexed: 01/28/2023] Open
Abstract
An increasing number of Nuclear Medicine sites in Europe are using cardiac-centered gamma cameras for myocardial perfusion scintigraphy (MPS). Three cardiac-centered gamma cameras are currently the most frequently used in Europe: the D-SPECT (Spectrum Dynamics), the Alcyone (Discovery NM 530c and Discovery NM/CT 570c; General Electric Medical Systems), and the IQ-SPECT (Siemens Healthcare). The increased myocardial count sensitivity of these three cardiac-centered systems has allowed for a decrease in the activities of radiopharmaceuticals injected to patients for myocardial perfusion imaging and, consequently, radiation exposure of patients. When setting up protocols for MPS, the overall objective should be to maintain high diagnostic accuracy of MPS, while injecting the lowest activities reasonably achievable to reduce the level of radiation exposure of patient and staff. These guidelines aim at providing recommendations for acquisition protocols and image interpretation using cardiac-centered cameras. As each imaging system has specific design and features for image acquisition and analysis, these guidelines have been separated into three sections for each gamma camera system. These recommendations have been written by the members of the Cardiovascular Committee of EANM and were based on their own experience with each of these systems and on the existing literature.
Collapse
Affiliation(s)
- Fabien Hyafil
- Department of Nuclear Medicine; Bichat University Hospital, Assistance Publique - Hôpitaux de Paris; Inserm UMR 1148, Paris Diderot-Paris 7 University, 46 rue Henri Huchard, 75018, Paris, France.
| | | | - Riemer H J A Slart
- Medical Imaging Center, Department of Nuclear Medicine and Molecular Imaging, University Medical Center Groningen, Groningen, The Netherlands.,TechMed Centre, Department of Biomedical Photonic Imaging, University of Twente, Enschede, The Netherlands
| | - Panagiotis Georgoulias
- Department of Nuclear Medicine, University of Thessaly, University Hospital of Larissa, Larissa, Greece
| | - Christoph Rischpler
- Department of Nuclear Medicine, University Hospital Essen, University of Duisburg-Essen, Essen, Germany
| | - Mark Lubberink
- Department of Medical Physics and PET Centre, Uppsala University Hospital, Uppsala, Sweden
| | - Roberto Sciagra
- Nuclear Medicine Unit, Department of Experimental and Clinical Biomedical Sciences, University of Florence, Florence, Italy
| | - Jan Bucerius
- Department of Nuclear Medicine, Maastricht University Medical Center and Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Center, Maastricht, The Netherlands.,Department of Nuclear Medicine, University Hospital RWTH Aachen, Aachen, Germany
| | - Denis Agostini
- Department of Nuclear Medicine, CHU Caen Normandy University, Caen, France
| | - Hein J Verberne
- Department of Radiology and Nuclear Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| | | |
Collapse
|
11
|
Comparative Cardiac Phantom Study Using Tc-99m/I-123 and Tl-201/I-123 Tracers with Cadmium-Zinc-Telluride Detector-Based Single-Photon Emission Computed Tomography. Nucl Med Mol Imaging 2019; 53:57-63. [PMID: 30828402 DOI: 10.1007/s13139-018-0559-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2018] [Revised: 11/08/2018] [Accepted: 12/04/2018] [Indexed: 12/25/2022] Open
Abstract
Objective A recently introduced single-photon emission computed tomography (SPECT), based on cadmium-zinc-telluride (CZT) detectors (D-SPECT), supports high energy resolution for cardiac imaging. Importantly, the high energy resolution may allow simultaneous dual-isotope (SDI) imaging (e.g., using Tc-99m and I-123). We quantitatively evaluated Tc-99m/I-123 SDI imaging by D-SPECT in comparison with conventional T1-201/I-123. Materials and Methods Energy resolution was measured as a percentage of the full width at half maximum (FWHM) for Tc-99m, I-123, and Tl-201. The impact of cross-talk and reconstructed image contrast were quantified by measuring the contrast-to-noise ratio (CNR), and the transmural defect contrast in the left ventricle wall (C TD) induced by a difference in energy, for combinations of Tc-99m/I-123 or Tl-201/I-123, using an RH-2 cardiac phantom. Corresponding measurement was also carried out in Anger SPECT (A-SPECT). Results The energy resolution of the D-SPECT system was 5.4%/5.1% for Tc-99m/I-123 and 5.4%/5.3% for Tl-201/I-123, which was approximately two times higher than the A-SPECT. No notable difference was confirmed in the CNRs of the two systems, but T1-201/I-123 showed overall higher value than Tc-99m/I-123. Compared to A-SPECT, C TD of D-SPECT significantly increased with both Tc-99m/I-123 and T1-201/I-123 (p < 0.05). In DSPECT, the combination of Tc-99m/I-123 had a slightly better C TD than T1-201/I-123. In addition, C TD of Tc-99m/I-123 was improved with scatter correction at both nuclides (p < 0.05), but in Tl-201/I-123, no significant improvement was confirmed in I-123 (p > 0.05). Conclusion D-SPECT was considered to be capable of performing high-quality SDI imaging using Tc-99m/I-123.
Collapse
|
12
|
Peters A, Kumar J, Patil PV. Diagnostic implications of CZT SPECT and impact of CT attenuation correction. J Nucl Cardiol 2019; 26:246-249. [PMID: 28646293 DOI: 10.1007/s12350-017-0961-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2017] [Accepted: 06/02/2017] [Indexed: 02/07/2023]
Affiliation(s)
- Andrew Peters
- Section of Cardiology, Department of Medicine, Lewis Katz School of Medicine at Temple University, 9th Floor Parkinson Pavilion, 3401 N. Broad Street, Philadelphia, PA, 19140, USA
| | - Jeevan Kumar
- Section of Cardiology, Department of Medicine, Lewis Katz School of Medicine at Temple University, 9th Floor Parkinson Pavilion, 3401 N. Broad Street, Philadelphia, PA, 19140, USA
| | - Pravin V Patil
- Section of Cardiology, Department of Medicine, Lewis Katz School of Medicine at Temple University, 9th Floor Parkinson Pavilion, 3401 N. Broad Street, Philadelphia, PA, 19140, USA.
| |
Collapse
|
13
|
Niimi T, Nanasato M, Sugimoto M, Maeda H. Evaluation of Cadmium-Zinc-Telluride Detector-based Single-Photon Emission Computed Tomography for Nuclear Cardiology: a Comparison with Conventional Anger Single-Photon Emission Computed Tomography. Nucl Med Mol Imaging 2017; 51:331-337. [PMID: 29242727 DOI: 10.1007/s13139-017-0474-9] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2016] [Revised: 12/05/2016] [Accepted: 01/30/2017] [Indexed: 11/30/2022] Open
Abstract
Purpose The differences in performance between the cadmium-zinc-telluride (CZT) camera or collimation systems and conventional Anger single-photon emission computed tomography (A-SPECT) remain insufficient from the viewpoint of the user. We evaluated the performance of the D-SPECT (Spectrum Dynamics, Israel) system to provide more information to the cardiologist or radiological technologist about its use in the clinical field. Materials and Methods This study evaluated the performance of the D-SPECT system in terms of energy resolution, detector sensitivity, spatial resolution, modulation transfer function (MTF), and collimator resolution in comparison with that of A-SPECT (Bright-View, Philips, Japan). Energy resolution and detector sensitivity were measured for Tc-99m, I-123, and Tl-201. The SPECT images produced by both systems were evaluated visually using the anthropomorphic torso phantom. Results The energy resolution of D-SPECT with Tc-99m and I-123 was approximately two times higher than that of A-SPECT. The detector sensitivity of D-SPECT was higher than that of A-SPECT (Tc-99m: 4.2 times, I-123: 2.2 times, and Tl-201: 5.9 times). The mean spatial resolution of D-SPECT was two times higher than that of A-SPECT. The MTF of D-SPECT was superior to that of the A-SPECT system for all frequencies. The collimator resolution of D-SPECT was lower than that of A-SPECT; however, the D-SPECT images clearly indicated better spatial resolution than the A-SPECT images. Conclusion The energy resolution, detector sensitivity, spatial resolution, and MTF of D-SPECT were superior to those of A-SPECT. Although the collimator resolution was lower than that of A-SPECT, the D-SPECT images were clearly of better quality.
Collapse
Affiliation(s)
- Takanaga Niimi
- Department of Radiological Technology, Nagoya Daini Red Cross Hospital, Takanaga Niimi, 2-9 Myouken-cho, Showa-ku, Nagoya, 466-8650 Japan
| | - Mamoru Nanasato
- Cardiovascular Center, Nagoya Daini Red Cross Hospital, 2-9 Myouken-cho, Showa-ku, Nagoya, 466-8650 Japan
| | - Mitsuo Sugimoto
- Department of Radiological Technology, Nagoya Daini Red Cross Hospital, Takanaga Niimi, 2-9 Myouken-cho, Showa-ku, Nagoya, 466-8650 Japan
| | - Hisatoshi Maeda
- Department of Radiological Technology, Nagoya University School of Health Sciences, 1-1-20 Daiko-minami, Higashi-ku, Nagoya, 461-8673 Japan
| |
Collapse
|
14
|
Performance of cardiac cadmium-zinc-telluride gamma camera imaging in coronary artery disease: a review from the cardiovascular committee of the European Association of Nuclear Medicine (EANM). Eur J Nucl Med Mol Imaging 2016; 43:2423-2432. [PMID: 27542010 DOI: 10.1007/s00259-016-3467-5] [Citation(s) in RCA: 64] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2016] [Accepted: 07/11/2016] [Indexed: 10/21/2022]
Abstract
The trade-off between resolution and count sensitivity dominates the performance of standard gamma cameras and dictates the need for relatively high doses of radioactivity of the used radiopharmaceuticals in order to limit image acquisition duration. The introduction of cadmium-zinc-telluride (CZT)-based cameras may overcome some of the limitations against conventional gamma cameras. CZT cameras used for the evaluation of myocardial perfusion have been shown to have a higher count sensitivity compared to conventional single photon emission computed tomography (SPECT) techniques. CZT image quality is further improved by the development of a dedicated three-dimensional iterative reconstruction algorithm, based on maximum likelihood expectation maximization (MLEM), which corrects for the loss in spatial resolution due to line response function of the collimator. All these innovations significantly reduce imaging time and result in a lower patient's radiation exposure compared with standard SPECT. To guide current and possible future users of the CZT technique for myocardial perfusion imaging, the Cardiovascular Committee of the European Association of Nuclear Medicine, starting from the experience of its members, has decided to examine the current literature regarding procedures and clinical data on CZT cameras. The committee hereby aims 1) to identify the main acquisitions protocols; 2) to evaluate the diagnostic and prognostic value of CZT derived myocardial perfusion, and finally 3) to determine the impact of CZT on radiation exposure.
Collapse
|
15
|
Ben-Haim S, Kennedy J, Keidar Z. Novel Cadmium Zinc Telluride Devices for Myocardial Perfusion Imaging—Technological Aspects and Clinical Applications. Semin Nucl Med 2016; 46:273-85. [DOI: 10.1053/j.semnuclmed.2016.01.002] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
|
16
|
Hung GU, Wang YF, Su HY, Hsieh TC, Ko CL, Yen RF. New Trends in Radionuclide Myocardial Perfusion Imaging. ACTA CARDIOLOGICA SINICA 2016; 32:156-66. [PMID: 27122946 DOI: 10.6515/acs20150803a] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
UNLABELLED Radionuclide myocardial perfusion imaging (MPI) with single photon emission computed tomography (SPECT) has been widely used clinically as one of the major functional imaging modalities for patients with coronary artery disease (CAD) for decades. Ample evidence has supported the use of MPI as a useful and important tool in the diagnosis, risk stratification and treatment planning for CAD. Although popular in the United States, MPI has become the most frequently used imaging modality among all nuclear medicine tests in Taiwan. However, it should be acknowledged that MPI SPECT does have its limitations. These include false-positive results due to certain artifacts, false-negative due to balanced ischemia, complexity and adverse reaction arising from current pharmacological stressors, time consuming nature of the imaging procedure, no blood flow quantitation and relatively high radiation exposure. The purpose of this article was to review the recent trends in nuclear cardiology, including the utilization of positron emission tomography (PET) for MPI, new stressor, new SPECT camera with higher resolution and higher sensitivity, dynamic SPECT protocol for blood flow quantitation, new software of phase analysis for evaluation of LV dyssynchrony, and measures utilized for reducing radiation exposure of MPI. KEY WORDS Coronary artery disease • Myocardial flow reserve • Myocardial perfusion imaging • Phase analysis • PET • SPECT.
Collapse
Affiliation(s)
- Guang-Uei Hung
- Department of Nuclear Medicine, Chang Bing Show Chwan Memorial Hospital, Changhua
| | - Yuh-Feng Wang
- Department of Nuclear Medicine, Buddhist Dalin Tzu Chi General Hospital, Chiayi; ; School of Medicine, Tzu Chi University, Hualian
| | - Hung-Yi Su
- Department of Nuclear Medicine, Cathay General Hospital, Taipei
| | - Te-Chun Hsieh
- Department of Nuclear Medicine and PET Center, China Medical University Hospital; ; Department of Biomedical Imaging and Radiological Science, China Medical University, Taichung
| | - Chi-Lun Ko
- Department of Nuclear Medicine, National Taiwan University Hospital Yun-Lin Branch, Yun-Lin
| | - Ruoh-Fang Yen
- Department of Nuclear Medicine, National Taiwan University Hospital; ; Department of Radiology, National Taiwan University College of Medicine, Taipei, Taiwan
| |
Collapse
|
17
|
Sharir T, Pinskiy M, Pardes A, Rochman A, Prokhorov V, Kovalski G, Merzon K, Bojko A, Brodkin B. Comparison of the diagnostic accuracies of very low stress-dose with standard-dose myocardial perfusion imaging: Automated quantification of one-day, stress-first SPECT using a CZT camera. J Nucl Cardiol 2016; 23:11-20. [PMID: 26012642 DOI: 10.1007/s12350-015-0130-7] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2015] [Accepted: 03/23/2015] [Indexed: 10/23/2022]
Abstract
BACKGROUND Previous studies have demonstrated accurate diagnosis of reduced dose myocardial perfusion imaging (MPI) using Cadmium-Zinc-Telluride (CZT) technology. We compared the diagnostic performances of very low stress-dose (<2 mSv) with standard-dose stress-first, quantitative MPI using a CZT camera. METHODS Patients without known coronary artery- disease who underwent a stress-first Tc-99 m sestamibi CZT-MPI and invasive coronary angiography (ICA), and low-risk patients without ICA were included. A stress-rest standard-dose (10/30 mCi) MPI and a low-dose (5/15 mCi) MPI were compared. Normal limits for quantification were developed from 40 (20 males) low-risk patients, and total perfusion deficit (TPD) was derived. RESULTS 208 patients who underwent MPI and ICA, and 76 low-risk patients were included. Of these, 128 had a standard-dose MPI and 156 had a low-dose MPI. Stress-doses in low-dose and standard-dose groups were 5.9 ± 1.2 vs 10.2 ± 0.5 mCi (1.7 ± 0.3 vs 3.0 ± 0.1 mSv), respectively, P < 0.001, and stress-rest effective radiation was 6.9 ± 1.1 vs 11.7 ± 0.4 mSv, respectively, P < 0.001. Sensitivity, specificity, and accuracy values in the low-dose and standard-dose groups were 86.1%, 76.6%, and 81.4%; and 90.6%, 78.1%, and 84.4%, respectively, P = ns. Using TPD prone, specificity values were 84.9% and 80.3%, respectively, P = ns. CONCLUSION One-day stress-first MPI with 50% radiation reduction and a very low stress-dose (<2 mSv) using CZT technology and quantitative supine and prone analysis provided a high diagnostic value, similar to standard-dose MPI.
Collapse
Affiliation(s)
- Tali Sharir
- Department of Nuclear Cardiology, Assuta Medical Centers, 96 Igal Alon, C Building, 67891, Tel Aviv, Israel.
| | - Marina Pinskiy
- Department of Nuclear Cardiology, Assuta Medical Centers, 96 Igal Alon, C Building, 67891, Tel Aviv, Israel
| | - Abraham Pardes
- Department of Nuclear Cardiology, Assuta Medical Centers, 96 Igal Alon, C Building, 67891, Tel Aviv, Israel
| | - Arik Rochman
- Department of Nuclear Cardiology, Assuta Medical Centers, 96 Igal Alon, C Building, 67891, Tel Aviv, Israel
| | - Vitali Prokhorov
- Department of Nuclear Cardiology, Assuta Medical Centers, 96 Igal Alon, C Building, 67891, Tel Aviv, Israel
| | | | - Konstantine Merzon
- Department of Nuclear Cardiology, Assuta Medical Centers, 96 Igal Alon, C Building, 67891, Tel Aviv, Israel
| | - Andrzej Bojko
- Department of Nuclear Cardiology, Assuta Medical Centers, 96 Igal Alon, C Building, 67891, Tel Aviv, Israel
| | - Boris Brodkin
- Department of Nuclear Cardiology, Assuta Medical Centers, 96 Igal Alon, C Building, 67891, Tel Aviv, Israel
- Department of Cardiology, Barzilai Medical Center, Ashkelon, Israel
- Faculty of Health Sciences, Ben-Gurion University of the Negev, Beersheba, Israel
| |
Collapse
|
18
|
Chikamori T, Hida S, Tanaka N, Igarashi Y, Yamashita J, Shiba C, Murata N, Hoshino K, Hokama Y, Yamashina A. Diagnostic Performance of a Cadmium-Zinc-Telluride Single-Photon Emission Computed Tomography System With Low-Dose Technetium-99m as Assessed by Fractional Flow Reserve. Circ J 2016; 80:1217-24. [DOI: 10.1253/circj.cj-16-0087] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
| | - Satoshi Hida
- Department of Cardiology, Tokyo Medical University
| | - Nobuhiro Tanaka
- Department of Cardiology, Tokyo Medical University Hachioji Medical Center
| | | | | | - Chie Shiba
- Department of Cardiology, Tokyo Medical University
| | | | - Kou Hoshino
- Department of Cardiology, Tokyo Medical University
| | - Yohei Hokama
- Department of Cardiology, Tokyo Medical University Hachioji Medical Center
| | | |
Collapse
|
19
|
Sørgaard M, Linde JJ, Kofoed KF, Kühl JT, Kelbæk H, Nielsen WB, Hove JD. Diagnostic Value of the Updated Diamond and Forrester Score to Predict Coronary Artery Disease in Patients with Acute-Onset Chest Pain. Cardiology 2015; 133:10-7. [PMID: 26389728 DOI: 10.1159/000438980] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/27/2014] [Accepted: 07/24/2015] [Indexed: 11/19/2022]
Abstract
OBJECTIVES In the recently updated clinical guidelines from the European Society of Cardiology on the management of stable coronary artery disease (CAD), the updated Diamond Forrester score has been included as a pretest probability (PTP) score to select patients for further diagnostic testing. We investigated the validity of the new guidelines in a population of patients with acute-onset chest pain. METHODS We examined 527 consecutive patients with either an exercise-ECG stress test or single-photon emission computed tomography, and subsequently coronary computed tomography angiography (CCTA). We compared the diagnostic accuracy of PTP and stress testing assessed by the area under the receiver operating characteristic curve (AUC) to identify significant CAD, defined as at least 1 coronary artery branch with >70% diameter stenosis identified by CCTA. RESULTS The diagnostic accuracy of PTP was significantly higher than the stress test (AUC 0.80 vs. 0.69; p = 0.009), but the diagnostic accuracy of the combination of PTP and a stress test did not significantly increase when compared to PTP alone (AUC 0.86 vs. 0.80; p = 0.06). CONCLUSIONS PTP using the updated Diamond and Forrester Score is a very useful tool in risk-stratifying patients with acute-onset chest pain at a low-to-intermediate risk of having CAD. Adding a stress test to PTP does not appear to offer significant diagnostic benefit.
Collapse
Affiliation(s)
- Mathias Sørgaard
- Department of Cardiology, The Heart Centre, University of Copenhagen, Copenhagen, Denmark
| | | | | | | | | | | | | |
Collapse
|
20
|
Barone-Rochette G, Leclere M, Calizzano A, Vautrin E, Céline GC, Broisat A, Ghezzi C, Baguet JP, Machecourt J, Vanzetto G, Fagret D. Stress thallium-201/rest technetium-99m sequential dual-isotope high-speed myocardial perfusion imaging validation versus invasive coronary angiography. J Nucl Cardiol 2015; 22:513-22. [PMID: 25381092 DOI: 10.1007/s12350-014-0016-0] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2014] [Accepted: 09/29/2014] [Indexed: 12/12/2022]
Abstract
BACKGROUND Recent advances in nuclear myocardial perfusion imaging (MPI) have made it possible to develop a dual-isotope protocol for high-speed acquisition with image quality and radiation delivery comparable to that obtained with conventional single isotope protocols. So far, no study has compared dual-isotope high-speed MPI to invasive coronary angiography (ICA) in a large cohort using a Cadmium-zinc-telluride SPECT system. METHODS Over a 1-year period (May 2011 to April 2012), 1366 patients underwent dual-isotope high-speed MPI. Patients with ICA within 3 months after dual-isotope high-speed MPI were included together with patients with a low likelihood of coronary artery disease (CAD) in order to assess normalcy rate. Global summed stress score (SSS) and summed rest score (SRS) were calculated, and ICA results were analyzed independently. The main end point was a patient-based assessment of the diagnostic performance of dual-isotope high-speed MPI in detecting or ruling out significant CAD (>70% reduction in lumen diameter). RESULTS Inclusion criteria were fulfilled for 214 patients (143 men; age 60 ± 14 years; ICA, n = 104; low likelihood for CAD, n = 110). An exercise stress test was performed in 62% of patients and a pharmacological stress test was performed with either dipyridamole (32%) or dobutamine (6%). Average examination duration was 22.4 ± 4.5 minutes. Mean SSS, SRS, and SDS were 8.0 ± 4.9, 3.1 ± 4.3, and 5.0 ± 3.2, respectively. Prevalence of angiographic CAD was 75%. ICA detected stenosis in the left main trunk, left anterior descending artery, left circumflex artery, and right coronary artery in 4, 33, 31, and 42 patients, respectively. Sensitivity of dual-isotope high-speed MPI was 94%, normalcy rate was 92%, and accuracy was 83% for detecting CAD. CONCLUSION Dual-isotope high-speed MPI is reliable at detecting or ruling out CAD. NCT01785589.
Collapse
Affiliation(s)
- Gilles Barone-Rochette
- Department of Cardiology, CHU Grenoble, University Hospital, BP 217, 38043, Grenoble Cedex 09, France,
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
21
|
Abstract
Positron-emitting myocardial flow radiotracers such as (15)O-water, (13)N-ammonia and (82)Rubidium in conjunction with positron-emission-tomography (PET) are increasingly applied in clinical routine for coronary artery disease (CAD) detection, yielding high diagnostic accuracy, while providing valuable information on cardiovascular (CV) outcome. Owing to a cyclotron dependency of (15)O-water and (13)N-ammonia, their clinical use for PET myocardial perfusion imaging is limited to a few centers. This limitation could be overcome by the increasing use of (82)Rubidium as it can be eluted from a commercially available (82)Strontium generator and, thus, is independent of a nearby cyclotron. Another novel F-18-labeled myocardial flow radiotracer is flurpiridaz which has attracted increasing interest due to its excellent radiotracer characteristics for perfusion and flow imaging with PET. In particular, the relatively long half-life of 109 minutes of flurpiridaz may afford a general application of this radiotracer for PET perfusion imaging comparable to technetium-99m-labeled single-photon emission computed tomography (SPECT). The ability of PET in conjunction with several radiotracers to assess myocardial blood flow (MBF) in ml/g/min at rest and during vasomotor stress has contributed to unravel pathophysiological mechanisms underlying coronary artery disease (CAD), to improve the detection and characterization of CAD burden in multivessel disease, and to provide incremental prognostic information in individuals with subclinical and clinically-manifest CAD. The concurrent evaluation of myocardial perfusion and MBF may lead to a new era of a personalized, image-guided therapy approach that may offer potential to further improve clinical outcome in CV disease patients but needing validation in large-scale clinical trials.
Collapse
Affiliation(s)
- Thomas H Schindler
- Division of Nuclear Medicine, Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, MD, USA.
| |
Collapse
|
22
|
Esteves FP, Galt JR, Folks RD, Verdes L, Garcia EV. Diagnostic performance of low-dose rest/stress Tc-99m tetrofosmin myocardial perfusion SPECT using the 530c CZT camera: quantitative vs visual analysis. J Nucl Cardiol 2014; 21:158-65. [PMID: 24287713 DOI: 10.1007/s12350-013-9827-7] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2013] [Accepted: 11/07/2013] [Indexed: 10/26/2022]
Abstract
BACKGROUND We set out to develop normal databases and prospectively validate abnormality criteria for a low-dose Tc-99m tetrofosmin myocardial perfusion SPECT protocol using the 530c CZT camera. METHODS All patients received 6 mCi rest/20 mCi stress doses of Tc-99m tetrofosmin. Rest and stress images were obtained over 7-9 and 5-7 minutes according to the chest size. Low-dose CT of the chest was obtained on a standalone CT scanner. Forty patients with very low likelihood (LLK) of coronary artery disease (CAD) were used to define the normal count distributions. The abnormality criteria were prospectively validated in 55 patients who had coronary angiography and in 40 patients with LLK of CAD. RESULTS The results for quantitative non-attenuation-corrected (AC) and AC analysis and visual analysis were as follows: sensitivity of 79%, 85%, and 92% (P = NS) and specificity of 44%, 75%, and 56% (P = NS), respectively. The normalcy rates for quantitative non-AC and AC analyses and visual analysis were 95%, 98%, and 98% (P = NS). CONCLUSIONS We have developed non-AC and AC normal databases for low-dose rest/stress Tc-99m tetrofosmin myocardial perfusion SPECT protocol using the 530c CZT camera. The per-patient diagnostic performance of quantitative analyses is not significantly different from visual analysis by an experienced reader.
Collapse
Affiliation(s)
- Fabio P Esteves
- Department of Radiology, Emory University School of Medicine, 1364 Clifton Road, NE, Atlanta, GA, 30322, USA,
| | | | | | | | | |
Collapse
|