1
|
Zhao Y, Lv T, Xu Y, Yin J, Wang X, Xue Y, Zhu G, Yu W, Wang H, Li X. Application of Dynamic [ 18F]FDG PET/CT Multiparametric Imaging Leads to an Improved Differentiation of Benign and Malignant Lung Lesions. Mol Imaging Biol 2024:10.1007/s11307-024-01942-w. [PMID: 39174787 DOI: 10.1007/s11307-024-01942-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2024] [Revised: 07/18/2024] [Accepted: 07/24/2024] [Indexed: 08/24/2024]
Abstract
PURPOSE To evaluate the potential of whole-body dynamic (WBD) 2-deoxy-2-[18F]fluoro-D-glucose positron emission tomography/computed tomography ([18F]FDG PET/CT) multiparametric imaging in the differential diagnosis between benign and malignant lung lesions. PROCEDURES We retrospectively analyzed WBD PET/CT scans from patients with lung lesions performed between April 2020 and March 2023. Multiparametric images including standardized uptake value (SUV), metabolic rate (MRFDG) and distribution volume (DVFDG) were visually interpreted and compared. We adopted SUVmax, metabolic tumor volume (MTV) and total lesion glycolysis (TLG) for semi-quantitative analysis, MRmax and DVmax values for quantitative analysis. We also collected the patients' clinical characteristics. The variables above with P-value < 0.05 in the univariate analysis were entered into a multivariate logistic regression. The statistically significant metrics were plotted on receiver-operating characteristic (ROC) curves. RESULTS A total of 60 patients were included for data evaluation. We found that most malignant lesions showed high uptake on MRFDG and SUV images, and low or absent uptake on DVFDG images, while benign lesions showed low uptake on MRFDG images and high uptake on DVFDG images. Most malignant lesions showed a characteristic pattern of gradually increasing FDG uptake, whereas benign lesions presented an initial rise with rapid fall, then kept stable at a low level. The AUC values of MRmax and SUVmax are 0.874 (95% CI: 0.763-0.946) and 0.792 (95% CI: 0.667-0.886), respectively. DeLong's test showed the difference between the areas is statistically significant (P < 0.001). CONCLUSIONS Our study demonstrated that dynamic [18F]FDG PET/CT imaging based on the Patlak analysis was a more accurate method of distinguishing malignancies from benign lesions than conventional static PET/CT scans.
Collapse
Affiliation(s)
- Yihan Zhao
- Department of Nuclear Medicine, The First Affiliated Hospital of Anhui Medical University, Hefei, China
| | - Tao Lv
- Department of Nuclear Medicine, The First Affiliated Hospital of Anhui Medical University, Hefei, China
| | - Yue Xu
- Department of Nuclear Medicine, The First Affiliated Hospital of Anhui Medical University, Hefei, China
| | - Jiankang Yin
- Department of Nuclear Medicine, The First Affiliated Hospital of Anhui Medical University, Hefei, China
| | - Xin Wang
- Department of Nuclear Medicine, The First Affiliated Hospital of Anhui Medical University, Hefei, China
| | - Yangyang Xue
- Department of Nuclear Medicine, The First Affiliated Hospital of Anhui Medical University, Hefei, China
| | - Gan Zhu
- Department of Nuclear Medicine, The First Affiliated Hospital of Anhui Medical University, Hefei, China
| | - Wenjing Yu
- Department of Nuclear Medicine, The First Affiliated Hospital of Anhui Medical University, Hefei, China
| | - Hui Wang
- Department of Nuclear Medicine, The First Affiliated Hospital of Anhui Medical University, Hefei, China
| | - Xiaohu Li
- Department of Radiology, The First Affiliated Hospital of Anhui Medical University, Research Center of Clinical Medical Imaging, Anhui Province Clinical Image Quality Control Center, Hefei, China.
| |
Collapse
|
2
|
Kaji T, Osanai K, Takahashi A, Kinoshita A, Satoh D, Nakata T, Tamaki N. Improvement of motion artifacts using dynamic whole-body 18F-FDG PET/CT imaging. Jpn J Radiol 2024; 42:374-381. [PMID: 38093138 PMCID: PMC10980605 DOI: 10.1007/s11604-023-01513-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2023] [Accepted: 11/05/2023] [Indexed: 04/01/2024]
Abstract
PURPOSE Serial dynamic whole-body PET imaging is valuable for assessing serial changes in tracer uptake. The purpose of this study was to evaluate the improvement of motion artifacts in patients using serial dynamic whole-body 18F-fluorodeoxyglyucose (FDG) PET/CT imaging. MATERIALS AND METHODS In 797 consecutive patients, serial 3-min dynamic whole-body FDG PET imaging was performed seven times, at 60 or 90 min after FDG administration. In cases with large body motion during imaging, we tried to improve the images by summing the images before body motion. An image quality study was performed on another 50 patients without obvious body motion using the same acquisition mode. RESULTS Obvious body movement was observed in 106 of 797 cases (13.3%), and severe motion artifacts which interfered image interpretation were observed in 18 (2.3%). In these 18 cases, summation of the images before the body movement enabled us to obtain images that excluded the effect of the body motion. In the visual evaluation of the image quality in another 50 patients studied, acceptable image quality was obtained when 2 or more times the serial 3-min image data were added. CONCLUSION Serial dynamic whole-body FDG PET imaging can minimize body motion artifacts by summation of the images before the body motion. Such serial dynamic study may be a choice for PET imaging to eliminate motion artifacts.
Collapse
Affiliation(s)
- Tomohito Kaji
- Department of Radiology, Division of Nuclear Medicine and PET Center, Hakodate Goryokaku Hospital, 38-3 Goryokaku-Cho, Hakodate, Hokkaido, 040-8611, Japan.
| | - Kouji Osanai
- Department of Radiology, Division of Nuclear Medicine and PET Center, Hakodate Goryokaku Hospital, 38-3 Goryokaku-Cho, Hakodate, Hokkaido, 040-8611, Japan
| | - Atsushi Takahashi
- Department of Radiology, Division of Nuclear Medicine and PET Center, Hakodate Goryokaku Hospital, 38-3 Goryokaku-Cho, Hakodate, Hokkaido, 040-8611, Japan
| | - Atsushi Kinoshita
- Department of Radiology, Division of Nuclear Medicine and PET Center, Hakodate Goryokaku Hospital, 38-3 Goryokaku-Cho, Hakodate, Hokkaido, 040-8611, Japan
| | - Daiki Satoh
- Department of Radiology, Division of Nuclear Medicine and PET Center, Hakodate Goryokaku Hospital, 38-3 Goryokaku-Cho, Hakodate, Hokkaido, 040-8611, Japan
| | - Tomoaki Nakata
- Department of Radiology, Division of Nuclear Medicine and PET Center, Hakodate Goryokaku Hospital, 38-3 Goryokaku-Cho, Hakodate, Hokkaido, 040-8611, Japan
| | - Nagara Tamaki
- Department of Radiology, Kyoto Prefectural University of Medicine, 465 Kajii-Cho, Kawaramachi-Hirokoji, Kamigyo-Ku, Kyoto, 602-8566, Japan
- Kyoto College of Medical Science, Oyama-Higashi, Sonobe, Nantan, Kyoto, 622-0041, Japan
| |
Collapse
|
3
|
Kato T, Ichikawa H, Shibutani T, Kita A, Watanabe M, Tada H, Sugiura A. A novel objective method for discriminating pathological and physiological colorectal uptake in the lower abdominal region using whole-body dynamic 18F-FDG-PET. Ann Nucl Med 2023; 37:561-571. [PMID: 37523072 DOI: 10.1007/s12149-023-01857-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2023] [Accepted: 07/09/2023] [Indexed: 08/01/2023]
Abstract
OBJECTIVES To investigate whether the center-of-mass shift distance (CMSD) analysis on whole-body dynamic positron emission tomography (WBD-PET) with continuous bed motion is an objective index for discriminating pathological and physiological uptake in the lower abdominal colon. METHODS We retrospectively analyzed the CMSD in 39 patients who underwent delayed imaging to detect incidental focal uptake that was difficult to determine as pathological and physiological on a conventional early-PET (early) image reconstructed by 5-phase WBD-PET images. The CMSD between each phase of WBD-PET images and between conventional early and delayed (two-phase) PET images were classified into pathological and physiological uptake groups based on endoscopic histology or other imaging diagnostics. The diagnostic performance of CMSD analysis on WBD-PET images was evaluated by receiver operator characteristic (ROC) analysis and compared to that of two-phase PET images. RESULTS A total of 66 incidental focal uptake detected early image were classified into 19 and 47 pathological and physiological uptake groups, respectively. The CMSD on WBD-PET and two-phase PET images in the pathological uptake group was significantly lower than that in the physiological uptake group (p < 0.01), respectively. The sensitivity, specificity, and accuracy in CMSD analysis on WBD-PET images at the optimal cutoff of 5.2 mm estimated by the Youden index were 94.7%, 89.4%, and 89.4%, respectively, which were not significantly different (p = 0.74) from those of two-phase PET images. CONCLUSIONS The CMSD analysis on WBD-PET was useful in discriminating pathological and physiological colorectal uptake in the lower abdominal region, and its diagnostic performance was comparable to that of two-phase PET images. We suggested that CMSD analysis on WBD-PET images would be a novel objective method to omit unnecessary additional delayed imaging.
Collapse
Affiliation(s)
- Toyohiro Kato
- Department of Radiology, Toyohashi Municipal Hospital, 50 Hakken-nishi, Aotake, Toyohashi, Aichi, 441-8570, Japan.
| | - Hajime Ichikawa
- Department of Radiology, Toyohashi Municipal Hospital, 50 Hakken-nishi, Aotake, Toyohashi, Aichi, 441-8570, Japan
- Department of Quantum Medical Technology, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, Kanazawa, Japan
| | - Takayuki Shibutani
- Department of Quantum Medical Technology, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, Kanazawa, Japan
| | - Akinobu Kita
- Radiological Center, University of Fukui Hospital, 23-3, Matsuoka-Shimoaizuki, Eiheiji-cho, Fukui, 910-1193, Japan
| | - Masanori Watanabe
- Department of Radiology, Fujita Health University Hospital, 1-98 Dengakugakubo, Kutsukake-cho, Toyoake, Aichi, 470-1192, Japan
| | - Hiroomi Tada
- Department of Diagnostic Radiology, Shizuoka Cancer Center, 1007 Shimonagakubo, Nagaizumi, Sunto, Shizuoka, 411-8777, Japan
| | - Akie Sugiura
- Department of Radiological Technology, Kariya Toyota General Hospital, 5-15 Sumiyoshi-cho, Kariya, Aichi, 448-8505, Japan
- Department of Quantum Medical Technology, Graduate School of Medical Sciences, Kanazawa University, Kanazawa, Japan
| |
Collapse
|
4
|
Tamaki N, Hirata K, Kotani T, Nakai Y, Matsushima S, Yamada K. Four-dimensional quantitative analysis using FDG-PET in clinical oncology. Jpn J Radiol 2023:10.1007/s11604-023-01411-4. [PMID: 36947283 PMCID: PMC10366296 DOI: 10.1007/s11604-023-01411-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2023] [Accepted: 03/02/2023] [Indexed: 03/23/2023]
Abstract
Positron emission tomography (PET) with F-18 fluorodeoxyglucose (FDG) has been commonly used in many oncological areas. High-resolution PET permits a three-dimensional analysis of FDG distributions on various lesions in vivo, which can be applied for tissue characterization, risk analysis, and treatment monitoring after chemoradiotherapy and immunotherapy. Metabolic changes can be assessed using the tumor absolute FDG uptake as standardized uptake value (SUV) and metabolic tumor volume (MTV). In addition, tumor heterogeneity assessment can potentially estimate tumor aggressiveness and resistance to chemoradiotherapy. Attempts have been made to quantify intratumoral heterogeneity using radiomics. Recent reports have indicated the clinical feasibility of a dynamic FDG PET-computed tomography (CT) in pilot cohort studies of oncological cases. Dynamic imaging permits the assessment of temporal changes in FDG uptake after administration, which is particularly useful for differentiating pathological from physiological uptakes with high diagnostic accuracy. In addition, several new parameters have been introduced for the in vivo quantitative analysis of FDG metabolic processes. Thus, a four-dimensional FDG PET-CT is available for precise tissue characterization of various lesions. This review introduces various new techniques for the quantitative analysis of FDG distribution and glucose metabolism using a four-dimensional FDG analysis with PET-CT. This elegant study reveals the important role of tissue characterization and treatment strategies in oncology.
Collapse
Affiliation(s)
- Nagara Tamaki
- Department of Radiology, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto, Japan.
| | - Kenji Hirata
- Department of Diagnostic Imaging, Hokkaido University Graduate School of Medicine, Sapporo, Japan
| | - Tomoya Kotani
- Department of Radiology, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto, Japan
| | - Yoshitomo Nakai
- Department of Radiology, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto, Japan
| | - Shigenori Matsushima
- Department of Radiology, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto, Japan
| | - Kei Yamada
- Department of Radiology, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto, Japan
| |
Collapse
|
5
|
Nii T, Hosokawa S, Kotani T, Domoto H, Nakamura Y, Tanada Y, Kondo R, Takahashi Y. Evaluation of Data-Driven Respiration Gating in Continuous Bed Motion in Lung Lesions. J Nucl Med Technol 2023; 51:32-37. [PMID: 36750380 DOI: 10.2967/jnmt.122.264909] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2022] [Revised: 01/04/2023] [Accepted: 01/04/2023] [Indexed: 02/09/2023] Open
Abstract
Respiration gating is used in PET to prevent image quality degradation due to respiratory effects. In this study, we evaluated a type of data-driven respiration gating for continuous bed motion, OncoFreeze AI, which was implemented to improve image quality and the accuracy of semiquantitative uptake values affected by respiratory motion. Methods: 18F-FDG PET/CT was performed on 32 patients with lung lesions. Two types of respiration-gated images (OncoFreeze AI with data-driven respiration gating, device-based amplitude-based OncoFreeze with elastic motion compensation) and ungated images (static) were reconstructed. For each image, we calculated SUV and metabolic tumor volume (MTV). The improvement rate (IR) from respiration gating and the contrast-to-noise ratio (CNR), which indicates the improvement in image noise, were also calculated for these indices. IR was also calculated for the upper and lower lobes of the lung. As OncoFreeze AI assumes the presence of respiratory motion, we examined quantitative accuracy in regions where respiratory motion was not present using a 68Ge cylinder phantom with known quantitative accuracy. Results: OncoFreeze and OncoFreeze AI showed similar values, with a significant increase in SUV and decrease in MTV compared with static reconstruction. OncoFreeze and OncoFreeze AI also showed similar values for IR and CNR. OncoFreeze AI increased SUVmax by an average of 18% and decreased MTV by an average of 25% compared with static reconstruction. From the IR results, both OncoFreeze and OncoFreeze AI showed a greater IR from static reconstruction in the lower lobe than in the upper lobe. OncoFreeze and OncoFreeze AI increased CNR by 17.9% and 18.0%, respectively, compared with static reconstruction. The quantitative accuracy of the 68Ge phantom, assuming a region of no respiratory motion, was almost equal for the static reconstruction and OncoFreeze AI. Conclusion: OncoFreeze AI improved the influence of respiratory motion in the assessment of lung lesion uptake to a level comparable to that of the previously launched OncoFreeze. OncoFreeze AI provides more accurate imaging with significantly larger SUVs and smaller MTVs than static reconstruction.
Collapse
Affiliation(s)
- Takeshi Nii
- Division of Radiological Technology, Department of Medical Technology, University Hospital, Kyoto Prefectural University of Medicine, Kyoto, Japan;
| | - Shota Hosokawa
- Department of Radiation Science, Graduate School of Health Sciences, Hirosaki University, Hirosaki, Japan
| | - Tomoya Kotani
- Department of Radiology, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto, Japan
| | - Hiroshi Domoto
- Division of Radiological Technology, Department of Medical Technology, University Hospital, Kyoto Prefectural University of Medicine, Kyoto, Japan
| | - Yasunori Nakamura
- Division of Radiological Technology, Department of Medical Technology, University Hospital, Kyoto Prefectural University of Medicine, Kyoto, Japan.,Department of Medical Physics, Graduate School of Medical Sciences, Kindai University, Osaka, Japan; and
| | - Yasutomo Tanada
- Division of Radiological Technology, Department of Medical Technology, University Hospital, Kyoto Prefectural University of Medicine, Kyoto, Japan.,Department of Quantum Medical Technology, Graduate School of Medical Sciences, Kanazawa University, Ishikawa, Japan
| | - Ryotaro Kondo
- Division of Radiological Technology, Department of Medical Technology, University Hospital, Kyoto Prefectural University of Medicine, Kyoto, Japan
| | - Yasuyuki Takahashi
- Department of Radiation Science, Graduate School of Health Sciences, Hirosaki University, Hirosaki, Japan
| |
Collapse
|
6
|
Wumener X, Zhang Y, Wang Z, Zhang M, Zang Z, Huang B, Liu M, Huang S, Huang Y, Wang P, Liang Y, Sun T. Dynamic FDG-PET imaging for differentiating metastatic from non-metastatic lymph nodes of lung cancer. Front Oncol 2022; 12:1005924. [PMID: 36439506 PMCID: PMC9686335 DOI: 10.3389/fonc.2022.1005924] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2022] [Accepted: 10/25/2022] [Indexed: 08/13/2023] Open
Abstract
OBJECTIVES 18F-fluorodeoxyglucose (FDG) PET/CT has been widely used in tumor diagnosis, staging, and response evaluation. To determine an optimal therapeutic strategy for lung cancer patients, accurate staging is essential. Semi-quantitative standardized uptake value (SUV) is known to be affected by multiple factors and may fail to differentiate between benign and malignant lesions. Lymph nodes (LNs) in the mediastinal and pulmonary hilar regions with high FDG uptake due to granulomatous lesions such as tuberculosis, which has a high prevalence in China, pose a diagnostic challenge. This study aims to evaluate the diagnostic value of the quantitative metabolic parameters derived from dynamic 18F-FDG PET/CT in differentiating metastatic and non-metastatic LNs in lung cancer. METHODS One hundred and eight patients with pulmonary nodules were enrolled to perform 18F-FDG PET/CT dynamic + static imaging with informed consent. One hundred and thirty-five LNs in 29 lung cancer patients were confirmed by pathology. Static image analysis parameters including LN-SUVmax, LN-SUVmax/primary tumor SUVmax (LN-SUVmax/PT-SUVmax), mediastinal blood pool SUVmax (MBP-SUVmax), LN-SUVmax/MBP-SUVmax, and LN-SUVmax/short diameter. Quantitative parameters including K1, k2, k3 and Ki and of each LN were obtained by applying the irreversible two-tissue compartment model using in-house Matlab software. Ki/K1 was computed subsequently as a separate marker. We further divided the LNs into mediastinal LNs (N=82) and pulmonary hilar LNs (N=53). Wilcoxon rank-sum test or Independent-samples T-test and receiver-operating characteristic (ROC) analysis was performed on each parameter to compare the diagnostic efficacy in differentiating lymph node metastases from inflammatory uptake. P<0.05 were considered statistically significant. RESULTS Among the 135 FDG-avid LNs confirmed by pathology, 49 LNs were non-metastatic, and 86 LNs were metastatic. LN-SUVmax, MBP-SUVmax, LN-SUVmax/MBP-SUVmax, and LN-SUVmax/short diameter couldn't well differentiate metastatic from non-metastatic LNs (P>0.05). However, LN-SUVmax/PT-SUVmax have good performance in the differential diagnosis of non-metastatic and metastatic LNs (P=0.039). Dynamic metabolic parameters in addition to k3, the parameters including K1, k2, Ki, and Ki/K1, on the other hand, have good performance in the differential diagnosis of metastatic and non-metastatic LNs (P=0.045, P=0.001, P=0.001, P=0.001, respectively). For ROC analysis, the metabolic parameters Ki (AUC of 0.672 [0.579-0.765], sensitivity 0.395, specificity 0.918) and Ki/K1 (AUC of 0.673 [0.580-0.767], sensitivity 0.570, specificity 0.776) have good performance in the differential diagnosis of metastatic from non-metastatic LNs than SUVmax (AUC of 0.596 [0.498-0.696], sensitivity 0.826, specificity 0.388), included the mediastinal region and pulmonary hilar region. CONCLUSION Compared with SUVmax, quantitative parameters such as K1, k2, Ki and Ki/K1 showed promising results for differentiation of metastatic and non-metastatic LNs with high uptake. The Ki and Ki/K1 had a high differential diagnostic value both in the mediastinal region and pulmonary hilar region.
Collapse
Affiliation(s)
- Xieraili Wumener
- Department of Nuclear Medicine, National Cancer Center, National Clinical Research Center for Cancer, Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shenzhen, China
| | - Yarong Zhang
- Department of Nuclear Medicine, National Cancer Center, National Clinical Research Center for Cancer, Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shenzhen, China
| | - Zhenguo Wang
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Maoqun Zhang
- Department of Nuclear Medicine, National Cancer Center, National Clinical Research Center for Cancer, Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shenzhen, China
| | | | - Bin Huang
- Department of Nuclear Medicine, National Cancer Center, National Clinical Research Center for Cancer, Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shenzhen, China
| | - Ming Liu
- Department of Nuclear Medicine, National Cancer Center, National Clinical Research Center for Cancer, Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shenzhen, China
| | - Shengyun Huang
- Department of Nuclear Medicine, National Cancer Center, National Clinical Research Center for Cancer, Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shenzhen, China
| | - Yong Huang
- Department of Nuclear Medicine, National Cancer Center, National Clinical Research Center for Cancer, Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shenzhen, China
| | - Peng Wang
- Department of Nuclear Medicine, National Cancer Center, National Clinical Research Center for Cancer, Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shenzhen, China
| | - Ying Liang
- Department of Nuclear Medicine, National Cancer Center, National Clinical Research Center for Cancer, Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shenzhen, China
| | - Tao Sun
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| |
Collapse
|
7
|
Watanabe M, Kato H, Katayama D, Soeda F, Matsunaga K, Watabe T, Tatsumi M, Shimosegawa E, Tomiyama N. Semiquantitative analysis using whole-body dynamic F-18 fluoro-2-deoxy-glucose-positron emission tomography to differentiate between benign and malignant lesions. Ann Nucl Med 2022; 36:951-963. [PMID: 36057012 DOI: 10.1007/s12149-022-01784-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2022] [Accepted: 08/16/2022] [Indexed: 12/01/2022]
Abstract
OBJECTIVES To investigate whether whole-body dynamic positron emission tomography (PET) is useful for differentiating benign and malignant lesions. METHODS In this retrospective study, data from a cohort of 146 lesions from 187 patients who consecutively underwent whole-body dynamic PET scans at our hospital for suspected lesions in the lung, lymph nodes, liver, bone, esophagus, and colon were analyzed. Patients with malignant lymphomas, accumulations > 5 cm in length along the long axis of the esophagus, or lesions in the colon in which the site of accumulation moved during the imaging period were excluded. Patients were administered 3.7 MBq/kg of fluorine-18-fluorodeoxyglucose (F-18 FDG), and dynamic imaging was initiated 60 min after administration. We defined the 60-65, 65-70, 70-75, and 75-80 min time mark as the first, second, third, and fourth pass, respectively. The static image is the summed average of all the four pass images. We measured the accumulation in the mean image of the whole-body dynamic PET scan, which was arithmetically similar to the maximum standardized uptake value (SUVmax) throughout the whole-body static images obtained during 20 min of imaging (S-SUVmax). The ratio of SUVmax in the dynamic first pass(60-65 min after FDG administration) and fourth pass(75-80 min after FDG administration) was calculated as R-SUVmax. RESULTS The S-SUVmax in the lung, lymph nodes, and bone did not differ significantly between the benign and malignant groups. However, there was a significant difference in R-SUVmax, which was > 1 in most malignant lesions indicating an increase in accumulation during routine scan time. Significant differences were observed between benign and malignant lesions of the liver in both S-SUVmax and R-SUVmax values, with the latter being > 1 in most malignant lesions. CONCLUSIONS Whole-body dynamic PET for 20 min starting 1 h after FDG administration improved the accuracy of malignant lesion detection in the liver, lymph nodes, lung, and bone. The incremental improvement was small, and the FDG dynamics in the distribution of values between benign and malignant overlapped. Additional information from whole-body dynamic imaging can help detect malignant lesions in these sites without increasing patient burden or prolonging imaging time.
Collapse
Affiliation(s)
- Mirei Watanabe
- Department of Nuclear Medicine and Tracer Kinetics, Graduate School of Medicine, Osaka University, 2-2 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Hiroki Kato
- Department of Nuclear Medicine and Tracer Kinetics, Graduate School of Medicine, Osaka University, 2-2 Yamadaoka, Suita, Osaka, 565-0871, Japan. .,Institute for Radiation Sciences, Osaka University, 2-2 Yamadaoka, Suita, Osaka, 565-0871, Japan.
| | - Daisuke Katayama
- Department of Nuclear Medicine and Tracer Kinetics, Graduate School of Medicine, Osaka University, 2-2 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Fumihiko Soeda
- Department of Nuclear Medicine and Tracer Kinetics, Graduate School of Medicine, Osaka University, 2-2 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Keiko Matsunaga
- Department of Molecular Imaging in Medicine, Graduate School of Medicine, Osaka University, 2-1 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Tadashi Watabe
- Department of Nuclear Medicine and Tracer Kinetics, Graduate School of Medicine, Osaka University, 2-2 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Mitsuaki Tatsumi
- Department of Nuclear Medicine and Tracer Kinetics, Graduate School of Medicine, Osaka University, 2-2 Yamadaoka, Suita, Osaka, 565-0871, Japan.,Department of Diagnostic and Interventional Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Eku Shimosegawa
- Department of Molecular Imaging in Medicine, Graduate School of Medicine, Osaka University, 2-1 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Noriyuki Tomiyama
- Department of Diagnostic and Interventional Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka, 565-0871, Japan
| |
Collapse
|
8
|
Dynamic PET in prostate cancer: basic concepts and potential applications. Clin Transl Imaging 2022. [DOI: 10.1007/s40336-022-00499-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
9
|
Lu W, Qiu J, Xie X, Li K, Duan Y, Li M, Ma C, Cheng Z, Liu S. Recognizing Tumor Origin for Lymphoid Tumor of Unknown Primary via Total-Body PET/CT Scan—Case Report. Front Oncol 2022; 12:766490. [PMID: 35186725 PMCID: PMC8850463 DOI: 10.3389/fonc.2022.766490] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2021] [Accepted: 01/07/2022] [Indexed: 11/13/2022] Open
Abstract
Localizing the site of tumor origin for patients with lymphoid tumor is fairly difficult before the definitive detection of the primary tumor, which causes redundant imaging examinations and medical costs. To circumvent this obstacle, the emergence of the world’s first total-body positron emission tomography/computed tomography (PET/CT) provides a transformative platform for simultaneously static and dynamic human molecular imaging. Here, we reported a case of lymph node metastasis from an unknown primary tumor, and the primary tumor was detected with the aid of the total-body PET/CT scanner. This patient with right neck mass was subjected to static and dynamic PET scan, as the static PET imaging found irregular thickening of the upper rectal wall and the dynamic PET imaging recognized the associations between the lymph metastasis and the rectal tumor lesions. The diagnosis by the total-body PET/CT was confirmed by pathological examination.
Collapse
Affiliation(s)
- Weizhao Lu
- Science and Technology Innovation Center, Shandong First Medical University & Shandong Academy of Medical Sciences, Jinan, China
- Department of Radiology, Shandong First Medical University & Shandong Academy of Medical Sciences, Taian, China
| | - Jianfeng Qiu
- Department of Radiology, Shandong First Medical University & Shandong Academy of Medical Sciences, Taian, China
| | - Xue Xie
- Science and Technology Innovation Center, Shandong First Medical University & Shandong Academy of Medical Sciences, Jinan, China
- Department of Radiology, Shandong First Medical University & Shandong Academy of Medical Sciences, Taian, China
| | - Kun Li
- Department of PET-CT, The First Affiliated Hospital of Shandong First Medical University, Shandong Provincial Qianfoshan Hospital Affiliated to Shandong University, Jinan, China
| | - Yanhua Duan
- Department of PET-CT, The First Affiliated Hospital of Shandong First Medical University, Shandong Provincial Qianfoshan Hospital Affiliated to Shandong University, Jinan, China
| | - Min Li
- Science and Technology Innovation Center, Shandong First Medical University & Shandong Academy of Medical Sciences, Jinan, China
| | - Chao Ma
- Science and Technology Innovation Center, Shandong First Medical University & Shandong Academy of Medical Sciences, Jinan, China
| | - Zhaoping Cheng
- Department of PET-CT, The First Affiliated Hospital of Shandong First Medical University, Shandong Provincial Qianfoshan Hospital Affiliated to Shandong University, Jinan, China
- *Correspondence: Zhaoping Cheng, ; Sijin Liu,
| | - Sijin Liu
- Science and Technology Innovation Center, Shandong First Medical University & Shandong Academy of Medical Sciences, Jinan, China
- State Key Laboratory of Environment Chemistry and Ecotoxicology, Research Center for Eco-Environment Sciences, Chinese Academy of Sciences, Beijing, China
- *Correspondence: Zhaoping Cheng, ; Sijin Liu,
| |
Collapse
|
10
|
Kotani T, Nishimura M, Tamaki N, Matsushima S, Akiyama S, Kanayama T, Bamba C, Tanada Y, Nii T, Yamada K. Comparison between dynamic whole-body FDG-PET and early-delayed imaging for the assessment of motion in focal uptake in colorectal area. Ann Nucl Med 2021; 35:1305-1311. [PMID: 34426890 DOI: 10.1007/s12149-021-01671-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2021] [Accepted: 08/15/2021] [Indexed: 10/20/2022]
Abstract
OBJECTIVES Serial changes of focal uptake in whole-body dynamic positron emission tomography (PET) imaging were assessed and compared with those in early-delayed imaging to differentiate pathological uptake from physiological uptake in the colorectal area, based on the change in uptake shape. METHODS In 60 patients with at least 1 pathologically diagnosed colorectal cancer or adenoma, a serial 3 min dynamic whole-body PET/computed tomography imaging was performed four times around 60 min after the administration of 18F-fluorodeoxyglucose (FDG) to create a conventional (early) image by summation. Delayed imaging was performed separately at 110 min after FDG administration. High focal uptake lesions in the colorectal area were visually assessed as "changed" or "unchanged" on serial dynamic imaging and early-delayed imaging, based on the alteration in uptake shape over time. These criteria on the images were used to differentiate pathological uptake from physiological uptake. RESULTS In this study, 334 lesions with high focal FDG uptake were observed. Among 73 histologically proven pathological FDG uptakes, no change was observed in 69 on serial dynamic imaging and 72 on early-delayed imaging (sensitivity of 95 vs. 99%, respectively; ns). In contrast, out of 261 physiological FDG uptakes, a change in uptake shape was seen in 159 on dynamic PET imaging and 66 on early-delayed imaging (specificity of 61 vs. 25%, respectively; p < 0.01). High and similar negative predictive values for identifying pathological uptake were obtained by both methods (98 vs 99%, respectively). Thus, the overall accuracy for differentiating pathological from physiological FDG uptake based on change in uptake shape tended to be higher on serial dynamic imaging (68%) than on early-delayed imaging (41%; p < 0.01). CONCLUSIONS Dynamic whole-body FDG imaging enables differentiation of pathological uptake from physiological uptake based on the serial changes in uptake shape in the colorectal area. It may provide greater diagnostic value than early-delayed PET imaging. Thus, this technique holds a promise for minimizing the need for delayed imaging.
Collapse
Affiliation(s)
- Tomoya Kotani
- Department of Radiology, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto, Japan.
| | - Motoki Nishimura
- Department of Radiology, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto, Japan
| | - Nagara Tamaki
- Department of Radiology, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto, Japan
| | - Shigenori Matsushima
- Department of Radiology, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto, Japan
| | - Shimpei Akiyama
- Department of Radiology, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto, Japan
| | - Taisei Kanayama
- Department of Radiology, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto, Japan
| | - Chisa Bamba
- Department of Radiology, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto, Japan
| | - Yasutomo Tanada
- Department of Quantum Medical Technology, Graduate School of Medical Sciences, Kanazawa University, Kanazawa, Japan
- Department of Radiological Technology, University Hospital, Kyoto Prefectural University of Medicine, Kyoto, Japan
| | - Takeshi Nii
- Department of Radiological Technology, University Hospital, Kyoto Prefectural University of Medicine, Kyoto, Japan
- Department of Radiation Science, Graduate School of Health Sciences, Hirosaki University, Hirosaki, Japan
| | - Kei Yamada
- Department of Radiology, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto, Japan
| |
Collapse
|
11
|
Achievements of true whole-body imaging using a faster acquisition of the lower extremities in variable-speed continuous bed motion. Radiol Phys Technol 2021; 14:373-380. [PMID: 34697782 DOI: 10.1007/s12194-021-00640-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2021] [Revised: 10/17/2021] [Accepted: 10/18/2021] [Indexed: 10/20/2022]
Abstract
Variable-speed continuous bed motion 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG-PET/CT), a reliable imaging technique, allows setting the bed motion speed for arbitrary sections of the body. The purpose of this study was to evaluate the relationship between the PET image quality and the bed speed following shortening of the scanning time for the lower extremities to achieve whole-body acquisition optimization of the examination time. Four sets of images were created by editing four-phase dynamic whole-body PET/CT images acquired at a bed speed of 6 and 14 mm/s in the trunk and lower extremities, respectively. The signal-to-noise ratio (SNR) was calculated using regions of interest in the liver, gluteus muscles, thigh, and lower legs, and the relationship between the bed speed and the SNR was assessed. The number of patients with findings in the lower extremities among 967 cases was evaluated. Based on this relationship between the SNR and bed motion speed, it is reasonable to increase the speed of the lower extremities by up to three times that of the trunk. The findings from whole-body FDG-PET imaging revealed that the number of patients with detected lesions in the lower extremities was 6.6% (64/967), bone metastases were found in 2.6%, soft lesions in 1.8%, and inflammation in 2.3%. Images of the lower extremities, which have a better SNR than the trunk, can be acquired at a faster bed speed using the variable-speed continuous bed motion PET.
Collapse
|
12
|
Wang Q, Yang S, Tang W, Liu L, Chen Y. 68Ga-DOTA-FAPI-04 PET/CT as a Promising Tool for Differentiating Ovarian Physiological Uptake: Preliminary Experience of Comparative Analysis With 18F-FDG. Front Med (Lausanne) 2021; 8:748683. [PMID: 34671627 PMCID: PMC8522939 DOI: 10.3389/fmed.2021.748683] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2021] [Accepted: 09/09/2021] [Indexed: 11/13/2022] Open
Abstract
Objectives: This study aimed to investigate the physiological distribution characteristics of 68Ga-DOTA-FAPI-04 in the ovary, and assess the feasibility of early diagnosis of primary ovarian disease with 68Ga-DOTA-FAPI-04 PET/CT. Methods: We retrospectively analyzed the data of patients who received 18F-FDG and 68Ga-DOTA-FAPI-04 PET/CT scanning in the Nuclear Medicine Department of our hospital within 3 days from September 2020 to January 2021. We selected the data in which ovaries showed abnormal FDG activity. Patients with abnormal ovarian FDG uptake with focus confirmed by pathological biopsy or clinical follow-up as pathological changes were excluded. The uptake of tracers (18F-FDG and 68Ga-FAPI) was semi-quantitatively analyzed. Results: This study included 14 patients (average age was 38.6). Physiological ovarian uptake was mostly unilateral, and there was no significant difference in SUVmax between the left and right sides (FDGt = 0.272, FAPIt = 0.592). The ovary SUVmax of FDG (4.89 ± 1.84) was statistically significantly higher than that of FAPI (1.53 ± 0.37). The Le/Li ratio on FDG is 3.38 ± 1.81, TBR is 5.81 ± 1.98, while the Le/Li ratio on FAPI is 3.57 ± 1.26, TBR is 0.94 ± 0.19. Conclusion: Our research shows that ovarian functional or pathological changes can be manifested as FDG avid, while 68Ga-DOTA-FAPI-04 has no physiological accumulation in the ovary and is not affected by the menstrual cycle. Therefore, 68Ga-DOTA-FAPI-04 has unique advantages in the diagnosis of ovarian diseases, and can identify them early and accurately.
Collapse
Affiliation(s)
- Qixin Wang
- Department of Nuclear Medicine, The Affiliated Hospital of Southwest Medical University, Luzhou, China.,Nuclear Medicine and Molecular Imaging Key Laboratory of Sichuan Province, Luzhou, China
| | - Songsong Yang
- Department of Nuclear Medicine, The Affiliated Hospital of Southwest Medical University, Luzhou, China.,Nuclear Medicine and Molecular Imaging Key Laboratory of Sichuan Province, Luzhou, China
| | - Wenxin Tang
- Department of Nuclear Medicine, The Affiliated Hospital of Southwest Medical University, Luzhou, China.,Nuclear Medicine and Molecular Imaging Key Laboratory of Sichuan Province, Luzhou, China
| | - Lin Liu
- Department of Nuclear Medicine, The Affiliated Hospital of Southwest Medical University, Luzhou, China.,Nuclear Medicine and Molecular Imaging Key Laboratory of Sichuan Province, Luzhou, China
| | - Yue Chen
- Department of Nuclear Medicine, The Affiliated Hospital of Southwest Medical University, Luzhou, China.,Nuclear Medicine and Molecular Imaging Key Laboratory of Sichuan Province, Luzhou, China
| |
Collapse
|