1
|
Inzerillo A, Meloni MF, Taibbi A, Bartolotta TV. Loco-regional treatment of hepatocellular carcinoma: Role of contrast-enhanced ultrasonography. World J Hepatol 2022; 14:911-922. [PMID: 35721286 PMCID: PMC9157715 DOI: 10.4254/wjh.v14.i5.911] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/25/2021] [Revised: 05/26/2021] [Accepted: 04/21/2022] [Indexed: 02/06/2023] Open
Abstract
Hepatocellular carcinoma (HCC) is one of the few cancers for which locoregional treatments (LRTs) are included in international guidelines and are considered as a valid alternative to conventional surgery. According to Barcelona Clinic Liver Cancer classification, percutaneous treatments such as percutaneous ethanol injection, radiofrequency ablation and microwave ablation are the therapy of choice among curative treatments in patients categorized as very early and early stage, while transcatheter arterial chemoembolization is considered the better option for intermediate stage HCC. A precise assessment of treatment efficacy and surveillance is essential to optimize survival rate, whereas residual tumor requires additional treatment. Imaging modalities play a key role in this task. Currently, contrast-enhanced computed tomography/magnetic resonance imaging are considered the standard imaging modalities for this purpose. Contrast enhanced ultrasound (CEUS), using second generation contrast agents, plays an increasingly important role in detecting residual disease after LRTs. CEUS is a straightforward to perform, repeatable and cost-effective imaging modality for patients with renal failure or iodine allergies. Due to the ability to focus on single regions, CEUS can also provide high temporal resolution. Moreover, several studies have reported the same or better diagnostic accuracy as contrast-enhanced computed tomography for assessing tumor vascularity 1 mo after LRTs, and recently three-dimensional (3D)-CEUS has been reported as a promising technique to improve the evaluation of tumor response to therapy. Furthermore, CEUS could be used early after procedures in monitoring HCC treatments, but nowadays this indication is still debated, and data from literature are conflicting, especially after transcatheter arterial chemoembolization procedure.
Collapse
Affiliation(s)
- Agostino Inzerillo
- Department of Radiology, University Hospital "Paolo Giaccone", Palermo 90127, Italy
| | | | - Adele Taibbi
- Department of Radiology, University Hospital "Paolo Giaccone", Palermo 90127, Italy
| | - Tommaso Vincenzo Bartolotta
- Department of Radiology, University Hospital "Paolo Giaccone", Palermo 90127, Italy
- Department of Radiology, Fondazione Istituto G. Giglio Hospital, Cefalù 90015, Italy
| |
Collapse
|
2
|
Ruan SM, Cheng MQ, Huang H, Hu HT, Li W, Xie XY, Lu MD, Kuang M, Lin MX, Wang W. Application of the CT/MRI LI-RADS Treatment Response Algorithm to Contrast-Enhanced Ultrasound: A Feasibility Study. J Hepatocell Carcinoma 2022; 9:437-451. [PMID: 35620274 PMCID: PMC9128751 DOI: 10.2147/jhc.s353914] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2021] [Accepted: 05/09/2022] [Indexed: 11/23/2022] Open
Abstract
Purpose The contrast-enhanced ultrasound (CEUS) Liver Imaging Reporting and Data System (LI-RADS) treatment response algorithm (TRA) is still in development. The aim of this study was to explore whether the CT/MRI LI-RADS TRA features were applicable to CEUS in evaluating the liver locoregional therapy (LRT) response. Patients and Methods This study was a retrospective review of a prospectively maintained database of patients with hepatocellular carcinoma undergoing ablation between July 2017 and December 2018. The standard criteria for a viable lesion were a histopathologically confirmed or typical viable appearance in the follow-up CT/MRI. Performance of the LI-RADS TRA assessing tumor viability was then compared between CEUS and CT/MRI. Inter-reader association was calculated. Results A total of 244 patients with 389 treated observations (118 viable) were evaluated. The sensitivity and specificity of the CEUS TRA and CT/MRI LI-RADS TRA viable categories for predicting viable lesions were 55.0% (65/118) versus 56.8% (67/118) (P = 0.480) and 99.3% (269/271) versus 96.3% (261/271) (P = 0.013), respectively. The PPV of CEUS was higher than that of CT/MRI (97.0% vs 87.0%). Subgroup analysis showed that the sensitivity was low in the 1-month assessment for both CEUS (38.1%, 16/42) and CT/MR (47.6%, 20/42) and higher in the 2–6-month assessment for both CEUS (65.7%, 23/35) and CT/MR (62.9%, 22/35). Interobserver agreements were substantial for both CEUS TRA and CT/MRI LI-RADS TRA (κ, 0.74 for both). Conclusion The CT/MRI LI-RADS TRA features were applicable to CEUS TRA for liver locoregional therapy. The CEUS TRA for liver locoregional therapy has sufficiently high specificity and PPV to diagnose the viability of lesions after ablation.
Collapse
Affiliation(s)
- Si-Min Ruan
- Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, Guangdong, People’s Republic of China
| | - Mei-Qing Cheng
- Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, Guangdong, People’s Republic of China
| | - Hui Huang
- Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, Guangdong, People’s Republic of China
| | - Hang-Tong Hu
- Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, Guangdong, People’s Republic of China
| | - Wei Li
- Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, Guangdong, People’s Republic of China
| | - Xiao-Yan Xie
- Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, Guangdong, People’s Republic of China
| | - Ming-De Lu
- Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, Guangdong, People’s Republic of China
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, Guangdong, People’s Republic of China
| | - Ming Kuang
- Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, Guangdong, People’s Republic of China
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, Guangdong, People’s Republic of China
| | - Man-Xia Lin
- Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, Guangdong, People’s Republic of China
| | - Wei Wang
- Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, Guangdong, People’s Republic of China
- Correspondence: Man-Xia Lin; Wei Wang, Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, The First Affiliated Hospital of Sun Yat-Sen University, 58 Zhongshan Road 2, Guangzhou, 510080, People’s Republic of China, Tel/Fax +86-20-87765183, Email ;
| |
Collapse
|
3
|
Mogahed M, Zytoon AA, Abdel Haleem A, Imam E, Ghanem N, Abdellatif WM. The value of intra-operative ultrasonography on safety margin and outcome during liver resection and radio-frequency ablation in the management of hepatocellular carcinoma patients. THE EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE 2021. [DOI: 10.1186/s43055-021-00567-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
Abstract
Background
Hepatocellular carcinoma (HCC) is an important health issue worldwide. Liver resection is the optimal management for early compensated HCC patients, but the majority of HCC patients are not candidates for resection. Several nonsurgical treatment modalities such as radio-frequency ablation (RFA), microwave ablation (MWA), trans-arterial chemoembolization, and immune therapy have been established. Intra-operative ultrasound (IOUS) is essential for accurate staging and secures both resection and RFA. We aimed to detect the value of using IOUS on safety margin and outcome during liver resection and RFA in the management of HCC patients. In the current study, 76 HCC patients, 58 males and 18 females, were included. Patients' age ranged from 49 to 69 years. Patients were divided into two groups: 52 open surgery liver resections (open resection group) and 24 laparoscopic-assisted RFA guided with laparoscopic IOUS (LARFA group). The open resection group was further subdivided into 32 cases for whom IOUS was performed and 20 patients studied retrospectively without IOUS. Surgical decisions were based on preoperative ultrasonography, computed tomography, and/or magnetic resonance imaging (MRI). We determined the size, number of lesions, and location by IOUS and compared them with preoperative imaging. Histopathology was done for resected lesions and follow-up CT for all patients.
Results
In the open resection group, the 32 cases of 52 for whom IOUS was performed, all had free surgical margin (100%) while 18 of 20 patients studied retrospectively without IOUS had free surgical margin (90%). Patients operated guided by IOUS had less morbidity and mortality with less operative time and hospital stay. In the LARFA group (24 patients with 37 lesions), the one-month follow-up showed complete ablation for all lesions in the 24 patients, while 12-month follow-up proved two cases of recurrence.
Conclusions
IOUS is a cornerstone in liver surgery. It improves outcomes with less morbidity and mortality and helps to achieve free surgical margin. Using IOUS allows the performance of radical but conservative hepatic resection.
Collapse
|
4
|
Early Identification of Residual Tumors following Microwave Ablation Using Contrast-Enhanced Ultrasonography in a Rabbit VX2 Liver Cancer Model. BIOMED RESEARCH INTERNATIONAL 2020; 2020:2462058. [PMID: 33029496 PMCID: PMC7537715 DOI: 10.1155/2020/2462058] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/30/2019] [Accepted: 07/01/2019] [Indexed: 11/17/2022]
Abstract
Objective It is difficult to evaluate the ablation effect immediately after thermal ablation of liver cancer by clinical imaging methods, due to the immediate formation of an annular inflammatory reaction band (IRB). This study is aimed at exploring the early identification indicators of the IRB and residual tumor postmicrowave ablation (MVA) using contrast-enhanced ultrasonography (CEUS). Methods MVA was used to inactivate part of the tumor nodules in rabbit VX2 liver cancer models, leading to the coexistence of the IRB with residual tumors. Quantitative analysis of the perfusion parameters of the tumor and ablation zone was performed using CEUS, followed by liver biopsy and VEGFR-2 immunohistochemical staining. Results All rabbits successfully tolerated VX2 tumor inoculation and MVA operation. No statistically significant difference existed between the IRB vs. residual tumors, the IRB vs. junctional areas, and residual tumors postablation vs. VX2 tumors before ablation in regional blood volume, blood velocity, and blood flow estimated by parameters A, k, and A∗k of CEUS quantitative analysis. There was a statistically significant difference between the IRB and normal liver parenchyma in regional blood velocity and blood flow (p = 0.005 and p = 0.023, respectively). Normal liver parenchyma showed nonspecific VEGFR-2 staining, while VX2 tumor before ablation and residual tumor after ablation both showed positive VEGFR-2 staining; the necrosis zone showed negative staining by VEGFR-2 immunohistochemical staining. Conclusion MVA had no significant effect on the residual tumor hemodynamics. The blood flow in the IRB increased significantly as compared to normal liver parenchyma, resembling tumor hemodynamic patterns. CEUS can detect residual tumors immediately postablation only when they protrude from the annular-shaped IRB. In addition, VEGFR-2 targeted CEUS may have a great potential for detecting residual tumor after thermal ablation of hepatocellular carcinoma.
Collapse
|
5
|
Bartolotta TV, Sidoti Pinto A, Cannella R, Porrello G, Taravella R, Randazzo A, Taibbi A. Focal liver lesions: interobserver and intraobserver agreement of three-dimensional contrast-enhanced ultrasound-assisted volume measurements. Ultrasonography 2020; 40:333-341. [PMID: 33080667 PMCID: PMC8217797 DOI: 10.14366/usg.20025] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2020] [Accepted: 08/19/2020] [Indexed: 12/11/2022] Open
Abstract
PURPOSE This study was conducted to assess the interobserver and intraobserver agreement of three-dimensional contrast-enhanced ultrasound (3D-CEUS) volume calculations of focal liver lesions (FLLs). METHODS Thirty-nine patients (15 men and 24 women; mean age, 55.4 years) with 39 FLLs (mean size, 3.1±1.8 cm; size range, 1 to 8 cm) prospectively underwent 3D-CEUS. Four readers calculated the volume of each lesion in an independent and blinded fashion in two separate sessions by means of a semi-automatic, commercially available proprietary software. The differences in lesion volumes (cm3) among sessions and readers were assessed using the Mann-Whitney U test and the Kruskal-Wallis test. Bland-Altman analysis was also performed. Intraclass correlation coefficients (ICCs) with 95% confidence intervals (95% CIs) were calculated. The statistical significance level was set at P<0.05. RESULTS Among readers, there were no statistically significant differences in the first (P=0.953) and second (P=0.592) reading sessions for volume calculations of the 39 FLLs, with almost perfect inter-reader agreement (ICC values of the first reading session, 0.996; 95% CI, 0.992 to 0.998 and ICC value of the second reading session, 0.994; 95% CI, 0.990 to 0.997, respectively). For each of the four readers, there were no significant differences in volume calculations between the two sessions (P=0.503-0.924), and the intrareader agreement was almost perfect for each reader (R1: ICC, 0.995; 95% CI, 0.991 to 0.998; R2: ICC, 0.995; 95% CI, 0.988 to 0.997; R3: ICC, 0.996; 95% CI, 0.992 to 0.998; R4: ICC, 0.985; 95% CI, 0.971 to 0.992). CONCLUSION 3D-CEUS volume calculations provided consistent measurements across different readers with almost perfect intrareader agreement.
Collapse
Affiliation(s)
- Tommaso Vincenzo Bartolotta
- Section of Radiology - BiND, University Hospital "Paolo Giaccone", Palermo, Italy.,Department of Radiology, Fondazione Istituto Giuseppe Giglio, Palermo, Italy
| | - Antonio Sidoti Pinto
- Section of Radiology - BiND, University Hospital "Paolo Giaccone", Palermo, Italy
| | - Roberto Cannella
- Section of Radiology - BiND, University Hospital "Paolo Giaccone", Palermo, Italy
| | - Giorgia Porrello
- Section of Radiology - BiND, University Hospital "Paolo Giaccone", Palermo, Italy
| | - Rossana Taravella
- Section of Radiology - BiND, University Hospital "Paolo Giaccone", Palermo, Italy
| | - Angelo Randazzo
- Section of Radiology - BiND, University Hospital "Paolo Giaccone", Palermo, Italy
| | - Adele Taibbi
- Section of Radiology - BiND, University Hospital "Paolo Giaccone", Palermo, Italy
| |
Collapse
|
6
|
Bartolotta TV, Terranova MC, Gagliardo C, Taibbi A. CEUS LI-RADS: a pictorial review. Insights Imaging 2020; 11:9. [PMID: 32020352 PMCID: PMC7000618 DOI: 10.1186/s13244-019-0819-2] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2019] [Accepted: 11/21/2019] [Indexed: 12/12/2022] Open
Abstract
Contrast-enhanced ultrasound (CEUS) greatly improved the diagnostic accuracy of US in the detection and characterization of focal liver lesions (FLLs), and it is suggested and often included in many international guidelines as an important diagnostic tool in the imaging work-up of cirrhotic patients at risk for developing hepatocellular carcinoma (HCC). In particular, CEUS Liver Imaging Reporting and Data System (LI-RADS) provides standardized terminology, interpretation, and reporting for the diagnosis of HCC. The aim of this pictorial essay is to illustrate CEUS features of nodules discovered at US in cirrhotic liver according to LI-RADS categorization.
Collapse
Affiliation(s)
- Tommaso Vincenzo Bartolotta
- BiND Department: Biomedicine, Neuroscience and Advanced Diagnostic, University of Palermo, Via Del Vespro, 129 90127, Palermo, Italy. .,Department of Radiology, Fondazione Istituto Giuseppe Giglio Ct.da Pietrapollastra, Via Pisciotto, 90015, Cefalù (Palermo), Italy.
| | - Maria Chiara Terranova
- BiND Department: Biomedicine, Neuroscience and Advanced Diagnostic, University of Palermo, Via Del Vespro, 129 90127, Palermo, Italy
| | - Cesare Gagliardo
- BiND Department: Biomedicine, Neuroscience and Advanced Diagnostic, University of Palermo, Via Del Vespro, 129 90127, Palermo, Italy
| | - Adele Taibbi
- BiND Department: Biomedicine, Neuroscience and Advanced Diagnostic, University of Palermo, Via Del Vespro, 129 90127, Palermo, Italy
| |
Collapse
|
7
|
Bartolotta TV, Taibbi A, Midiri M, Lagalla R. Contrast-enhanced ultrasound of hepatocellular carcinoma: where do we stand? Ultrasonography 2019; 38:200-214. [PMID: 31006227 PMCID: PMC6595127 DOI: 10.14366/usg.18060] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2018] [Accepted: 02/25/2019] [Indexed: 12/12/2022] Open
Abstract
Contrast-enhanced ultrasound (CEUS) represents a significant breakthrough in ultrasonography (US), and it is being increasingly used for the evaluation of focal liver lesions (FLLs). CEUS is unique in that it allows non-invasive assessment of liver perfusion in real time throughout the vascular phase, which has led to dramatic improvements in the diagnostic accuracy of US in the detection and characterization of FLLs, the choice of therapeutic procedures, and the evaluation of response. Currently, CEUS is included as a part of the suggested diagnostic work-up of FLLs, including in cirrhotic patients with hepatocellular carcinoma, resulting in better patient management and cost-effective delivery of therapy.
Collapse
Affiliation(s)
| | - Adele Taibbi
- Department of Radiology, University of Palermo, Palermo, Italy
| | - Massimo Midiri
- Department of Radiology, University of Palermo, Palermo, Italy
| | - Roberto Lagalla
- Department of Radiology, University of Palermo, Palermo, Italy
| |
Collapse
|
8
|
Cao J, Dong Y, Mao F, Wang W. Dynamic Three-Dimensional Contrast-Enhanced Ultrasound to Predict Therapeutic Response of Radiofrequency Ablation in Hepatocellular Carcinoma: Preliminary Findings. BIOMED RESEARCH INTERNATIONAL 2018; 2018:6469703. [PMID: 30225261 PMCID: PMC6129360 DOI: 10.1155/2018/6469703] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/09/2017] [Accepted: 08/06/2018] [Indexed: 12/21/2022]
Abstract
BACKGROUND & AIMS To investigate the value of dynamic three-dimensional contrast-enhanced ultrasound (3D-CEUS) in the assessment of therapeutic response of hepatocellular carcinoma (HCC) treated with radiofrequency ablation (RFA). METHODS Forty-two patients (31 men and 11 women; mean age (52.1 ± 13.1 years)) with 42 clinical diagnosed HCC lesions (size range 14-48 mm; mean size 28.4 ± 9.9 mm) treated by RFA were included. All patients underwent two-dimensional contrast-enhanced ultrasound (2D-CEUS) and 3D-CEUS 1 month after treatment. Two radiologists assessed the absence (complete response, CR) or presence (residual tumor, RT) of any arterially hyperenhancing nodules within or along the margin of the treated HCC lesions. Complete response on magnetic resonance (MR) imaging acted as standard of reference (SOR). RESULTS After RFA treatment, 3D-CEUS was successfully conducted in 34 HCC lesions. CR was observed on both 2D-CEUS and 3D-CEUS in 25/42 (59.5%) HCC and RT in 6/42 (14.3%) HCC lesions. In 3/42 (7.1%) HCC lesion, RT was documented by SOR and 3D-CEUS, but it was not appreciable at 2D-CEUS. In 3/42 (7.1%) HCC lesion, the presence of peripheral RT was suspected by both 2D-CEUS and 3D-CEUS, but it was not confirmed by SOR. No statistically significant difference between 2D-CEUS and 3D-CEUS in depicting either CR or RT was found (P = 0.25). Combined with dynamic 3D-CEUS, the diagnostic accuracy was improved from 85.7% to 92.9%. CONCLUSIONS 3D-CEUS might be helpful in better diagnostic performance in the assessment of therapeutic response of HCC treated after RFA.
Collapse
Affiliation(s)
- Jiaying Cao
- Department of Ultrasound, Zhongshan Hospital, Fudan University, 200032 Shanghai, China
| | - Yi Dong
- Department of Ultrasound, Zhongshan Hospital, Fudan University, 200032 Shanghai, China
| | - Feng Mao
- Shanghai Institute of Medical Imaging, 200032 Shanghai, China
| | - Wenping Wang
- Department of Ultrasound, Zhongshan Hospital, Fudan University, 200032 Shanghai, China
| |
Collapse
|
9
|
Tamarov K, Gongalsky M, Osminkina L, Huang Y, Omar M, Yakunin V, Ntziachristos V, Razansky D, Timoshenko V. Electrolytic conductivity-related radiofrequency heating of aqueous suspensions of nanoparticles for biomedicine. Phys Chem Chem Phys 2018; 19:11510-11517. [PMID: 28425519 DOI: 10.1039/c7cp00728k] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
The development of suitable contrast agents can significantly enhance the efficiency of modern imaging and treatment techniques, such as thermoacoustic (TA) tomography and radio-frequency (RF) hyperthermia of cancer. Here, we examine the heating of aqueous suspensions of silicon (Si) and gold (Au) nanoparticles (NPs) under RF irradiation in the MHz frequency range. The heating rate of aqueous suspensions of Si NPs exhibited non-monotonic dependency on the electrical conductivity of the suspension. The experimental results were explained by the mathematical model considering oscillating solvated ions as the main source of Joule heating. These ions could be the product of the dissolution of Si NPs or organic coating of Au NPs. Thus, the ions governed the conductivity of the suspensions, which in turn governs both the heating rate and the near-field RF TA response. The model predicted the contrast in different tissues taking into account both Joule heating and dielectric losses.
Collapse
Affiliation(s)
- Konstantin Tamarov
- Faculty of Physics, M. V. Lomonosov Moscow State University, 119991 Moscow, Russia. and Department of Applied Physics, University of Eastern Finland, 70211 Kuopio, Finland
| | - Maxim Gongalsky
- Faculty of Physics, M. V. Lomonosov Moscow State University, 119991 Moscow, Russia. and Institute of Biological and Medical Imaging, Helmholtz Zentrum München, 85764 Neuherberg, Germany
| | - Liubov Osminkina
- Faculty of Physics, M. V. Lomonosov Moscow State University, 119991 Moscow, Russia. and National Research Nuclear University "MEPhI", International Laboratory "Bionanophotonics", 115409 Moscow, Russia
| | - Yuanhui Huang
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, 85764 Neuherberg, Germany and Chair of Biological Imaging, Technische Universität München, 80333 Munich, Germany
| | - Murad Omar
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, 85764 Neuherberg, Germany and Chair of Biological Imaging, Technische Universität München, 80333 Munich, Germany
| | - Valery Yakunin
- Faculty of Physics, M. V. Lomonosov Moscow State University, 119991 Moscow, Russia.
| | - Vasilis Ntziachristos
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, 85764 Neuherberg, Germany and Chair of Biological Imaging, Technische Universität München, 80333 Munich, Germany
| | - Daniel Razansky
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, 85764 Neuherberg, Germany and Chair of Biological Imaging, Technische Universität München, 80333 Munich, Germany
| | - Victor Timoshenko
- Faculty of Physics, M. V. Lomonosov Moscow State University, 119991 Moscow, Russia. and National Research Nuclear University "MEPhI", International Laboratory "Bionanophotonics", 115409 Moscow, Russia
| |
Collapse
|
10
|
Cheng C, Xiao Z, Huang G, Zhang L, Bai J. Enhancing ablation effects of a microbubble contrast agent on high-intensity focused ultrasound: an experimental and clinical study. BJOG 2017; 124 Suppl 3:78-86. [DOI: 10.1111/1471-0528.14744] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/05/2017] [Indexed: 01/20/2023]
Affiliation(s)
- C Cheng
- Department of Ultrasound; the First Affiliated Hospital of Chongqing Medical University; Chongqing China
- State Key Laboratory of Ultrasound Engineering in Medicine Co-founded by Chongqing and the Ministry of Science and Technology; Chongqing Key Laboratory of Ultrasound in Medicine and Engineering; College of Biomedical Engineering; Chongqing Medical University; Chongqing China
| | - Z Xiao
- State Key Laboratory of Ultrasound Engineering in Medicine Co-founded by Chongqing and the Ministry of Science and Technology; Chongqing Key Laboratory of Ultrasound in Medicine and Engineering; College of Biomedical Engineering; Chongqing Medical University; Chongqing China
- Department of Radiology; the First Affiliated Hospital of Chongqing Medical University; Chongqing China
| | - G Huang
- Department of Obstetrics and Gynaecology; Suining Central Hospital; Sichuan China
| | - L Zhang
- State Key Laboratory of Ultrasound Engineering in Medicine Co-founded by Chongqing and the Ministry of Science and Technology; Chongqing Key Laboratory of Ultrasound in Medicine and Engineering; College of Biomedical Engineering; Chongqing Medical University; Chongqing China
| | - J Bai
- State Key Laboratory of Ultrasound Engineering in Medicine Co-founded by Chongqing and the Ministry of Science and Technology; Chongqing Key Laboratory of Ultrasound in Medicine and Engineering; College of Biomedical Engineering; Chongqing Medical University; Chongqing China
| |
Collapse
|
11
|
Shi W, He Y, Ding W, Gong S, Wang Y, Xiao J, He B. Contrast-enhanced ultrasonography used for post-treatment responses evaluation of radiofrequency ablations for hepatocellular carcinoma: a meta-analysis. Br J Radiol 2016; 89:20150973. [PMID: 27327401 DOI: 10.1259/bjr.20150973] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023] Open
Abstract
OBJECTIVE This meta-analysis aims to analyze the usefulness of contrast-enhanced ultrasonography (CEUS) for post-treatment responses evaluation of radiofrequency ablation (RFA) for hepatocellular carcinoma (HCC) management. METHODS Literature retrieval in three databases PubMed, Embase and Cochrane Library was conducted up to September 2015, with pre-defined criteria. The technical success rate, local tumour recurrence and local tumour progression were the measurement indexes. Cochran's Q test and I(2) were used for heterogeneity detection. Subgroup analyses were performed for complete ablation rate stratified by study designs, contrast agents and post-operative testing time points. Statistical analyses were conducted using Stata(®) 12.0 software (Stata Corporation, College Station, TX). RESULTS 12 studies consisting of 772 patients were included in this study. The CEUS-evaluated success rate of RFA for HCCs was 91%. The proportion of ablative margin <5 mm was 53%. The local tumour recurrence rate and local tumour progression rate were 4% and 8%, respectively. Subgroup analysis indicated that the CEUS-assessed technical success rate with Sonazoid™ (Daiichi-Sankyo, Tokyo, Japan) as the contrast agent was higher (95%) than those with other agents [SH U 508A (Schering AG, Berlin, Germany) 86%; SonoVue (Bracco SpA, Milan, Italy) 87%]. The success rate assessed within 24 h (94%) after treatment was higher than longer time (1-3 days 86%; 1 month 91%). CONCLUSION The meta-analysis showed that the CEUS-evaluated success rate of RFA for HCCs was 91%. The local tumour recurrence rate and local tumour progression rate were 4% and 8%, respectively. ADVANCES IN KNOWLEDGE Using meta-analysis, the study provided more reliable assessment of usefulness of CEUS, which could provide guidelines for HCC treatment.
Collapse
Affiliation(s)
- Weixiang Shi
- 1 Department of Radiology, Second Affiliated Hospital of Nantong University, Nantong, Jiangsu, China
| | - Ying He
- 2 Department of Ultrasound, Tumor Hospital of Nantong University, Nantong, Jiangsu, China
| | - Wenbin Ding
- 1 Department of Radiology, Second Affiliated Hospital of Nantong University, Nantong, Jiangsu, China
| | - Shenchu Gong
- 1 Department of Radiology, Second Affiliated Hospital of Nantong University, Nantong, Jiangsu, China
| | - Yilang Wang
- 3 Department of Oncology, Second Affiliated Hospital of Nantong University, Nantong, Jiangsu, China
| | - Jing Xiao
- 4 Department of Epidemiology and Medical Statistics, School of Public Health, Nantong University, Nantong, Jiangsu, China
| | - Bosheng He
- 1 Department of Radiology, Second Affiliated Hospital of Nantong University, Nantong, Jiangsu, China
| |
Collapse
|
12
|
Roccarina D, Garcovich M, Ainora ME, Riccardi L, Pompili M, Gasbarrini A, Zocco MA. Usefulness of contrast enhanced ultrasound in monitoring therapeutic response after hepatocellular carcinoma treatment. World J Hepatol 2015; 7:1866-1874. [PMID: 26207168 PMCID: PMC4506944 DOI: 10.4254/wjh.v7.i14.1866] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/02/2014] [Revised: 03/13/2015] [Accepted: 07/14/2015] [Indexed: 02/06/2023] Open
Abstract
In the last years, the development in the oncology field has been huge and rapid. In particular, the evaluation of response to anti-tumour treatments has been being object of intense research, producing significant changes. Response assessment after therapy in solid neoplasias has always used radiological imaging techniques, with tumour size reduction representing a presumed therapeutic efficacy. However, with the introduction of anti-angiogenetic drugs the evaluation of tumour size has become unsuitable because some tumours, under treatment, show only tumour perfusion changes rather than lesion shrinkage. Between different imaging techniques with contrast-enhancement, contrast-enhanced ultrasound (CEUS) and, in particular, dynamic CEUS have arisen as a promising and non-invasive device for monitoring cancer treatments. Moreover, the introduction of perfusion software has even more refined the technique since it is able to provide quantitative parameters related to blood flow and blood volume that can be associated with tumour response and clinical outcome such as the progression free survival and the overall survival. Here, we give an overview of the current status of CEUS in monitoring hepatocellular carcinoma response to different kind of treatments.
Collapse
|
13
|
The Role of Contrast-Enhanced Ultrasound in Guiding Radiofrequency Ablation of Hepatocellular Carcinoma. Can Assoc Radiol J 2015; 66:171-8. [DOI: 10.1016/j.carj.2014.11.005] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2014] [Accepted: 11/19/2014] [Indexed: 02/06/2023] Open
Abstract
Purpose The objective of the study was to determine the efficacy of contrast-enhanced ultrasound (CEUS) using ultrasound (US)-specific microbubbles in guiding radiofrequency ablation (RFA) of hepatocellular carcinoma (HCC). Methods A retrospective analysis of 50 patients with HCC treated with CEUS guided RFA using perflutren at our institution was performed. CEUS images were first compared to B-mode US images performed at the same RFA session to determine the ability of CEUS to increase the conspicuity of lesions. A qualitative score (1 = poor, 2 = fair, 3 = excellent) was used to grade the ability to visualize the lesions. The preprocedure CEUS images were then evaluated using the most recent prior contrast enhanced computed tomography (CT) or magnetic resonance imaging (MRI). The efficacy of the treatment was evaluated with short-term follow-up imaging (median 1 month) for presence of residual or recurrent disease. Results CEUS allows at least fair visualization (score ≥2) in 78% (reader 1) and 80% (reader 2) of the lesions not visualized by B-mode US, and 50% (reader 1) and 42% (reader 2) of the lesions poorly visualized by B-mode US. Lesion appearances on CEUS are largely concordant with those on CT or MRI: 88% for reader 1, 96% for reader 2. With CEUS-guided RFA, complete response was achieved in the vast majority of the lesions at short-term follow-up: 82% for reader 1, 94% for reader 2. Conclusions CEUS increases the conspicuity and provides better characterization of hypervascular HCC that are either not seen or poorly seen on B-mode US, and CEUS provides real-time guidance of RFA with good short-term treatment responses.
Collapse
|
14
|
Nishigaki Y, Hayashi H, Tomita E, Suzuki Y, Watanabe N, Watanabe S, Watanabe C, Takagi Y, Kato T, Naiki T. Usefulness of contrast-enhanced ultrasonography using Sonazoid for the assessment of therapeutic response to percutaneous radiofrequency ablation for hepatocellular carcinoma. Hepatol Res 2015; 45:432-40. [PMID: 24917381 DOI: 10.1111/hepr.12370] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/19/2014] [Revised: 06/01/2014] [Accepted: 06/05/2014] [Indexed: 02/08/2023]
Abstract
AIM Accurate assessment of the coagulated area is imperative to achieve an excellent outcome from percutaneous radiofrequency ablation (PRFA) for the treatment of hepatocellular carcinoma (HCC). We evaluated the efficacy of contrast-enhanced ultrasonography (CEUS) with the contrast-enhancing agent Sonazoid for precisely assessing the therapeutic effect of PRFA for HCC. METHODS We enrolled 87 consecutive patients with solitary naïve HCC of less than 3 cm in diameter. PRFA treatment was performed with a 17-G cool-tip needle, and CEUS was performed to assess the ablative margin 3 h after the procedure, when the coagulated tumor outline was easiest to discern. The treatment was repeated until an ablative margin greater than 5 mm was confirmed. After CEUS assessment of the therapeutic response, the patients were followed to investigate local tumor recurrence. RESULTS In 78 patients (89.7%), the outline of the coagulated tumors could be recognized by ultrasonography, and CEUS assessment of the ablative margin was successful. The remaining nine patients were assessed by computed tomography. The 5-year cumulative survival rate after the assessment of the treatment response with CEUS was 58.4%, and the 4-year cumulative total recurrence rate was 72.3%. The 5-year cumulative local tumor recurrence rate was very low (2.3%). CONCLUSION The assessment with CEUS at 3 h after the PRFA procedure was successful in the majority of the patients, and it yielded a very low rate of local recurrence.
Collapse
Affiliation(s)
- Yoichi Nishigaki
- Department of Gastroenterology and Hepatology, Gifu Municipal Hospital, Gifu, Japan
| | | | | | | | | | | | | | | | | | | |
Collapse
|
15
|
Cheng CQ, Zhang RT, Xiong Y, Chen L, Wang J, Huang GH, Li KQ, Zhang L, Bai J. Contrast-enhanced ultrasound for evaluation of high-intensity focused ultrasound treatment of benign uterine diseases: retrospective analysis of contrast safety. Medicine (Baltimore) 2015; 94:e729. [PMID: 25906100 PMCID: PMC4602694 DOI: 10.1097/md.0000000000000729] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/17/2023] Open
Abstract
As a noninvasive treatment technique, ultrasound-guided high-intensity focused ultrasound (HIFU) has been considered as a routine treatment for uterine fibroids and adenomyosis in China. Contrast-enhanced ultrasound (CEUS) has been proposed as another option to assess the treatment efficacy during HIFU treatment. The aim of this investigation is to evaluate the adverse effects of HIFU ablation for benign uterine diseases in a group of patients studied with ultrasound contrast agent (UCA), in comparison with a group of patients not exposed to UCA. From November 2010 to December 2013, 2604 patients with benign uterine diseases were treated with HIFU. Among them, 1300 patients were exposed to an UCA, whereas 1304 patients were not.During HIFU procedure, the incidences of leg pain, sacral/buttock pain, groin pain, treatment area pain, and the discomfort "hot" sensation on skin were higher in the patients who were exposed to SonoVue (Bracco, Milan, Italy) than those who were not (20.5% vs 11.7%, 52.5% vs 42.3%, 6.5% vs 4.5%, 68.9% vs 55.4%, and 48.1% vs 42.9%, respectively). Among the postoperative adverse effects, the incidence of lower abdominal pain was significantly higher in patients who were exposed to an UCA than those who were not (51.2% vs 39.9%, P < 0.05). Two patients who were exposed to an UCA had acute renal function failure.In conclusion, UCA may increase the incidences of some common HIFU-related adverse effects during HIFU treatment for benign uterine diseases, but most of which were acceptable and self-limited. After HIFU treatment, renal function should be monitored in patients with a history of hypertension or taking nonsteroidal anti-inflammatory drugs.
Collapse
Affiliation(s)
- Chong-Qing Cheng
- From State Key Laboratory of Ultrasound Engineering in Medicine Co-founded by Chongqing and the Ministry of Science and Technology (CQC, RTZ, JW, GHH, KQL, LZ, JB), Chongqing Key Laboratory of Ultrasound in Medicine and Engineering, College of Biomedical Engineering, Chongqing Medical University; Department of Obstetrics and Gynecology (RTZ), Fuling Central Hospital; Department of Obstetrics and Gynecology (YX, LC, KQL), Chongqing Haifu Hospital; Department of Obstetrics and Gynecology (JW), Three Gorges Central Hospital, Chongqing; and Department of Obstetrics and Gynecology (GHH), Suining Central Hospital, Sichuan, China
| | | | | | | | | | | | | | | | | |
Collapse
|
16
|
Peng S, Hu L, Chen W, Chen J, Yang C, Wang X, Zhang R, Wang Z, Zhang L. Intraprocedure contrast enhanced ultrasound: the value in assessing the effect of ultrasound-guided high intensity focused ultrasound ablation for uterine fibroids. ULTRASONICS 2015; 58:123-8. [PMID: 25627929 DOI: 10.1016/j.ultras.2015.01.005] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/23/2014] [Revised: 12/22/2014] [Accepted: 01/07/2015] [Indexed: 05/16/2023]
Abstract
PURPOSE To investigate the value of microbubble contrast-enhanced ultrasound (CEUS) in evaluating the treatment response of uterine fibroids to HIFU ablation. MATERIALS AND METHODS Sixty-eight patients with a solitary uterine fibroid from the First Affiliated Hospital of Chongqing Medical University were included and analyzed. All patients underwent pre- and post-treatment magnetic resonance imaging (MRI) with a standardized protocol, as well as pre-evaluation, intraprocedure, and immediate post-treatment CEUS. CEUS and MRI were compared by different radiologists. RESULTS In comparison with MRI, CEUS showed that the size of fibroids, volume of fibroids, size of non-perfused regions, non-perfused volume (NPV) or fractional ablation (NPV ratio) was similar to that of MRI. In terms of CEUS examination results, the median volume of fibroids was 75.2 (interquartile range, 34.2-127.3) cm(3), the median non-perfused volume was 54.9 (interquartile range, 28.0-98.1) cm(3), the mean fractional ablation was 83.7±13.6 (range, 30.0-100.0)%. In terms of MRI examination results, the median volume of fibroids was 74.1 (interquartile range, 33.4-116.2) cm(3). On the basis of contrast-enhanced T1-weighted images immediately after HIFU treatment, the median non-perfused volume was 58.5 (interquartile range, 27.7-100.0) cm(3), the average fractional ablation was 84.2±14.2 (range, 40.0-100.0)%. CONCLUSIONS CEUS clearly showed the size of fibroids and the non-perfused areas of the fibroid. Results from CEUS correlated well with results obtained from MRI.
Collapse
Affiliation(s)
- Song Peng
- State Key Laboratory of Ultrasound Engineering in Medicine Co-founded by Chongqing and the Ministry of Science and Technology, Chongqing Key Laboratory of Ultrasound in Medicine and Engineering, College of Biomedical Engineering, Chongqing Medical University, Chongqing 400016, China
| | - Liang Hu
- State Key Laboratory of Ultrasound Engineering in Medicine Co-founded by Chongqing and the Ministry of Science and Technology, Chongqing Key Laboratory of Ultrasound in Medicine and Engineering, College of Biomedical Engineering, Chongqing Medical University, Chongqing 400016, China
| | - Wenzhi Chen
- Clinical Center for Tumor Therapy of 2nd Affiliated Hospital of Chongqing Medical University, 74 Linjiang Road, Chongqing 400010, China
| | - Jinyun Chen
- State Key Laboratory of Ultrasound Engineering in Medicine Co-founded by Chongqing and the Ministry of Science and Technology, Chongqing Key Laboratory of Ultrasound in Medicine and Engineering, College of Biomedical Engineering, Chongqing Medical University, Chongqing 400016, China
| | - Caiyong Yang
- HIFU Center for Tumor Therapy of 1st Affiliated Hospital of Chongqing Medical University, 1 Youyi Road, Chongqing 400016, China
| | - Xi Wang
- HIFU Center for Tumor Therapy of 1st Affiliated Hospital of Chongqing Medical University, 1 Youyi Road, Chongqing 400016, China
| | - Rong Zhang
- HIFU Center for Tumor Therapy of 1st Affiliated Hospital of Chongqing Medical University, 1 Youyi Road, Chongqing 400016, China
| | - Zhibiao Wang
- State Key Laboratory of Ultrasound Engineering in Medicine Co-founded by Chongqing and the Ministry of Science and Technology, Chongqing Key Laboratory of Ultrasound in Medicine and Engineering, College of Biomedical Engineering, Chongqing Medical University, Chongqing 400016, China.
| | - Lian Zhang
- State Key Laboratory of Ultrasound Engineering in Medicine Co-founded by Chongqing and the Ministry of Science and Technology, Chongqing Key Laboratory of Ultrasound in Medicine and Engineering, College of Biomedical Engineering, Chongqing Medical University, Chongqing 400016, China.
| |
Collapse
|
17
|
Bartolotta TV, Taibbi A, Matranga D, Midiri M, Lagalla R. 3D versus 2D contrast-enhanced sonography in the evaluation of therapeutic response of hepatocellular carcinoma after locoregional therapies: preliminary findings. Radiol Med 2015; 120:695-704. [PMID: 25698299 DOI: 10.1007/s11547-015-0514-4] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2014] [Accepted: 01/28/2015] [Indexed: 12/12/2022]
Abstract
OBJECTIVE To investigate diagnostic performance of 3D contrast-enhanced ultrasound (CEUS) compared with 2D CEUS in the assessment of therapeutic response of hepatocellular carcinoma (HCC) treated with locoregional therapies (LRT). MATERIALS AND METHODS Twenty-three consecutive patients (13 men and 10 women; mean age 65.5 years) with 23 HCCs (size range 1.2-7.2 cm; mean size 2.9 ± 1.4 cm) treated by means of radiofrequency ablation (RFA n = 9), transarterial chemoembolization (TACE n = 8), combined RFA and TACE (n = 3), percutaneous alcoholization (n = 2), and wedge resection (n = 1) underwent 2D and 3D CEUS 1 month (30 ± 2 days) after treatment. Magnetic resonance (n = 17) and computed tomography (n = 6) acted as standard of reference (SOR). Two radiologists assessed the absence (complete response CR) or presence (residual tumor RT) of any nodular arterially enhancing area within or along the margin of the treated HCC. RESULTS Both 2D and 3D CEUS observed CR in 10/23 (43.5 %) HCCs and RT in 11/23 (47.8 %) HCCs. In 1/23 (4.3 %) HCC, RT was documented by SOR and 2D CEUS, but it was not appreciable at 3D CEUS. In 1/23 (4.3 %) HCC, the presence of peripheral residual tumor was suspected by both 2D and 3D CEUS, but it was not confirmed by SOR. No statistically significant difference between 2D and 3D CEUS in depicting either CR or RT was found (p > 0.05). Sensitivity, specificity, positive and negative predictive values, and accuracy of 3D CEUS were 91.7 % [95 % confidence interval (CI) 0.760-1.073], 90.9 % (95 % CI 0.739-1.079), 91.7, 90.9, and 91.3 %, respectively. CONCLUSION 2D and 3D CEUS provided similar diagnostic performance in the assessment of therapeutic response of HCC treated with LRT.
Collapse
|
18
|
Li X, Liang P, Yu J, Yu XL, Liu FY, Cheng ZG, Han ZY. Role of contrast-enhanced ultrasound in evaluating the efficiency of ultrasound guided percutaneous microwave ablation in patients with renal cell carcinoma. Radiol Oncol 2013; 47:398-404. [PMID: 24294186 PMCID: PMC3814286 DOI: 10.2478/raon-2013-0038] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2013] [Accepted: 04/04/2013] [Indexed: 01/20/2023] Open
Abstract
BACKGROUND The aim of the study was to evaluate the efficiency and feasibility of contrast-enhanced ultrasound (CEUS) with Sonovue in assessing of renal cell carcinomas (RCCs) following ultrasound (US)-guided percutaneous microwave ablation (MWA). PATINETS AND METHODS Seventy-nine patients (60 males and 19 females) with 83 lesions (mean size 3.2±1.6 cm) were treated by US-guided percutaneous MWA. The CEUS results of the third day after the ablation were compared with the synchronous contrast-enhanced computed tomography (CT)/magnetic resonance imaging (MRI) results and biopsy pathological results. The follow-up was performed by CEUS and CT/MRI after 1, 3, 6 months and every 6 months subsequently. The combination of clinical follow-up results and CT/MRI imaging findings was the reference standard of CEUS results for evaluating the therapeutic effect. The identification of residual or recurrence tumour was assessed by two blinded radiologists. RESULTS On the third day after MWA, CEUS showed 68 of 83 lesions (68/83, 81.9%) successfully ablated and 15 of 83 (18.1%) with residual tumours. Among residual tumours, 13 (86.7%) were confirmed by contrast-enhanced CT/MRI findings and biopsy results. The sensitivity, specificity, accuracy, positive and negative predictive value of CEUS evaluating the short-term MWA effectiveness were 100%, 97.1%, 97.6%, 86.7% and 100%, respectively. During the six years follow-up (median 26 months), the CEUS showed recurrence in 7 patients, and six of them achieved consistent results on CEUS and CT/MRI imaging. The sensitivity, specificity, accuracy, positive and negative predictive value for CEUS evaluating long-term MWA effectiveness were 85.7%, 98.7%, 97.6%, 85.7% and 98.7%, respectively. CONCLUSIONS The post-procedural CEUS demonstrated as an effective and feasible method in evaluating a therapeutic effect of RCCs following MWA.
Collapse
Affiliation(s)
- Xin Li
- Interventional Ultrasound Department of Chinese PLA General Hospital, Beijing, China
- Medical College of Nankai University, Tianjin, China
| | - Ping Liang
- Interventional Ultrasound Department of Chinese PLA General Hospital, Beijing, China
| | - Jie Yu
- Interventional Ultrasound Department of Chinese PLA General Hospital, Beijing, China
| | - Xiao-Ling Yu
- Interventional Ultrasound Department of Chinese PLA General Hospital, Beijing, China
| | - Fang-Yi Liu
- Interventional Ultrasound Department of Chinese PLA General Hospital, Beijing, China
| | - Zhi-Gang Cheng
- Interventional Ultrasound Department of Chinese PLA General Hospital, Beijing, China
| | - Zhi-Yu Han
- Interventional Ultrasound Department of Chinese PLA General Hospital, Beijing, China
| |
Collapse
|
19
|
Wu R, Xu FH, Yao MH, Xie J, Hu B. Contrast-enhanced ultrasonography follow-up after radiofrequency ablation in normal rabbit kidney. Arch Med Sci 2013; 9:608-13. [PMID: 24049518 PMCID: PMC3776188 DOI: 10.5114/aoms.2013.37271] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/13/2012] [Revised: 10/14/2012] [Accepted: 11/21/2012] [Indexed: 01/20/2023] Open
Abstract
INTRODUCTION The aim of this study was to evaluate the diagnostic performance of SonoVue-enhanced ultrasonography in the follow-up of rabbit kidney lesions induced by percutaneous radiofrequency ablation. MATERIAL AND METHODS New Zealand rabbits (28) underwent percutaneous radiofrequency ablation (RFA) to generate renal lesions. Lesions were evaluated by conventional 2D ultrasound and contrast-enhanced ultrasonography (CEUS) at 1 day, 1 week, 1 month and 3 months after RFA, and the results were compared to gross pathology. RESULTS One day and 1 week after RFA, renal lesions were wedge-shaped in the gross dissection cross-sectional profiles. Conventional ultrasound could not indicate the extent of the lesions; however, CEUS could exactly delineate the lesion shape and size. At 1 and 3 months, lesions were observed as hyperechogenic areas on conventional ultrasound, and as small perfusion defects on CEUS. The differences in the lesion measurements obtained by CEUS and in pathological specimens were not statistically significant (p > 0.05). CONCLUSIONS The conclusion could be deduced from the study that SonoVue-enhanced ultrasonography was effective for the follow-up of normal rabbit kidney percutaneous radiofrequency ablation.
Collapse
Affiliation(s)
- Rong Wu
- Department of Ultrasound in Medicine, Shanghai tenth People's Hospital, Tongji University School of Medicine, Shanghai, China
| | - Fan-hua Xu
- Department of Ultrasound in Medicine, the Second Clinical Medical College of Jinan University, Shenzhen People's Hospital, Shenzhen, China
| | - Ming-hua Yao
- Department of Ultrasound in Medicine, Shanghai tenth People's Hospital, Tongji University School of Medicine, Shanghai, China
| | - Juan Xie
- Department of Ultrasound in Medicine, Shanghai tenth People's Hospital, Tongji University School of Medicine, Shanghai, China
| | - Bing Hu
- Department of Ultrasound in Medicine, Shanghai Jiao Tong University affiliated Sixth People's Hospital, Shanghai, China
| |
Collapse
|
20
|
Alzaraa A, Gravante G, Chung WY, Al-Leswas D, Morgan B, Dennison A, Lloyd D. Contrast-enhanced ultrasound in the preoperative, intraoperative and postoperative assessment of liver lesions. Hepatol Res 2013; 43:809-19. [PMID: 23745715 DOI: 10.1111/hepr.12044] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/25/2012] [Revised: 12/04/2012] [Accepted: 12/10/2012] [Indexed: 12/12/2022]
Abstract
The use of contrast agents (CA) with liver ultrasound (US) has gained recently an established role for the diagnosis of various hepatic diseases due to their safety, high versatility and low costs (contrast-enhanced ultrasound: CEUS). The purpose of this review is to provide a state-of-the-art summary of the available evidence for their use in the characterization of focal liver lesions. A published work search was conducted for all preclinical and clinical studies involving CA on hepatic US imaging. CEUS increases the sensitivity for lesion detection and the specificity to differentiate between benign and malignant diseases due to the enhanced visualization of the tumor microcirculation. Results achieved seem at least equivalent to those of spiral computed tomography or magnetic resonance imaging. The association of CA with intraoperative ultrasound has changed the surgical approach in 25% of patients and guarantees complete ablations by a single session in most of them. CEUS provides detailed information about tumor vasculature, improves the preoperative characterization and therefore the therapeutic strategy, and can evaluate the intraoperative completeness of the ablation.
Collapse
Affiliation(s)
- Ahmed Alzaraa
- Department of General Surgery, William Harvey Hospital, Ashford
| | | | | | | | | | | | | |
Collapse
|
21
|
Wang XY, Chen D, Zhang XS, Chen ZF, Hu AB. Value of ¹⁸F-FDG-PET/CT in the detection of recurrent hepatocellular carcinoma after hepatectomy or radiofrequency ablation: a comparative study with contrast-enhanced ultrasound. J Dig Dis 2013; 14:433-8. [PMID: 23615075 DOI: 10.1111/1751-2980.12064] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
OBJECTIVE To evaluate the role of positron emission tomography/computer tomography with fluorine-18 fluorodeoxyglucose ((18) F-FDG-PET/CT) in detecting hepatocellular carcinoma (HCC) recurrence after hepatectomy and/or radiofrequency ablation (RFA) and to compare its efficacy with contrast-enhanced ultrasound (CEUS). METHODS A total of 36 HCC patients were included in this study. All patients underwent both (18) F-FDG-PET/CT and CEUS at least once for the diagnosis of HCC recurrence. The time interval between PET/CT and CEUS was 14 ± 3 days. All patients were followed up for at least 24 months. RESULTS In all, 32 patients were confirmed to have HCC recurrence by pathology and clinical follow-up. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of (18) F-FDG-PET/CT for intrahepatic HCC recurrence were 96.7%, 83.3%, 96.7%, 83.3% and 94.4%, respectively. The corresponding values of CEUS were 56.7%, 100%, 100%, 31.6% and 63.9%, respectively. The sensitivity and accuracy of (18) F-FDG-PET/CT for the diagnosis of HCC recurrence were significantly higher than those of CEUS (P < 0.01, respectively). CONCLUSIONS Compared with CEUS, (18) F-FDG-PET/CT has higher sensitivity and accuracy in detecting the local recurrence of HCC after hepatectomy and/or RFA. It can be used to detect recurrent extrahepatic lesions of HCC effectively.
Collapse
Affiliation(s)
- Xiao Yan Wang
- Department of Nuclear Medicine, First Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong Province, China
| | | | | | | | | |
Collapse
|
22
|
Zheng SG, Xu HX, Lu MD, Xie XY, Xu ZF, Liu GJ, Liu LN. Role of contrast-enhanced ultrasound in follow-up assessment after ablation for hepatocellular carcinoma. World J Gastroenterol 2013; 19:855-865. [PMID: 23430451 PMCID: PMC3574882 DOI: 10.3748/wjg.v19.i6.855] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/23/2012] [Revised: 12/03/2012] [Accepted: 12/25/2012] [Indexed: 02/06/2023] Open
Abstract
AIM: To assess the usefulness of contrast-enhanced ultrasound (CEUS) during follow-up after percutaneous ablation therapy for hepatocellular carcinoma (HCC).
METHODS: A total of 141 patients with HCCs who received percutaneous ablation therapy were assessed by paired follow-up CEUS and contrast-enhanced computed tomography (CECT). The follow-up scheme was designed prospectively and the intervals between CEUS and CECT examinations were less than 14 d. Both images of follow-up CEUS and CECT were reviewed by radiologists. The ablated lesions were evaluated and classified as local tumor progression (LTP) and LTP-free. LTP was defined as regrowth of tumor inside or adjacent to the successfully treated nodule. The detected new intrahepatic recurrences were also evaluated and defined as presence of intrahepatic new foci. On CEUS and CECT, LTP and new intrahepatic recurrence both were displayed as typical enhancement pattern of HCC (i.e., hyper-enhancing during the arterial phase and washout in the late phase). With CECT as the reference standard, the ability of CEUS in detecting LTP or new intrahepatic recurrence during follow-up was evaluated.
RESULTS: During a follow-up period of 1-31 mo (median, 4 mo), 169 paired CEUS and CECT examinations were carried out for the 141 patients. For a total of 221 ablated lesions, 266 comparisons between CEUS and CECT findings were performed. Thirty-three LTPs were detected on CEUS whereas 40 LTPs were detected on CECT, there was significant difference (P < 0.001). In comparison with CECT, the numbers of false positive and false negative LTPs detected on CEUS were 6 and 13, respectively; the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and overall accuracy of CEUS in detecting LTPs were 67.5%, 97.4%, 81.8%, 94.4% and 92.3%, respectively. Meanwhile, 131 new intrahepatic recurrent foci were detected on CEUS whereas 183 were detected on CECT, there was also significant difference (P < 0.05). In comparison with CECT, the numbers of false positive and false negative intrahepatic recurrences detected on CEUS were 13 and 65, respectively; the sensitivity, specificity, PPV, NPV and overall accuracy of CEUS in detecting new intrahepatic recurrent foci were 77.7%, 92.0%, 92.4%, 76.7% and 84.0%, respectively.
CONCLUSION: The sensitivity of CEUS in detecting LTP and new intrahepatic recurrence after percutaneous ablation therapy is relatively low in comparison with CECT.
Collapse
|
23
|
Peng S, Xiong Y, Li K, He M, Deng Y, Chen L, Zou M, Chen W, Wang Z, He J, Zhang L. Clinical utility of a microbubble-enhancing contrast (“SonoVue”) in treatment of uterine fibroids with high intensity focused ultrasound: A retrospective study. Eur J Radiol 2012; 81:3832-8. [DOI: 10.1016/j.ejrad.2012.04.030] [Citation(s) in RCA: 57] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2012] [Revised: 04/24/2012] [Accepted: 04/25/2012] [Indexed: 11/26/2022]
|
24
|
Zhao X, Wang W, Zhang S, Liu J, Zhang F, Ji C, Li X, Gan W, Zhang G, Guo H. Improved outcome of percutaneous radiofrequency ablation in renal cell carcinoma: a retrospective study of intraoperative contrast-enhanced ultrasonography in 73 patients. Abdom Radiol (NY) 2012; 37:885-91. [PMID: 22131041 DOI: 10.1007/s00261-011-9828-4] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
OBJECTIVES To evaluate the impact of contrast-enhanced ultrasonography (CEUS) during percutaneous radiofrequency ablation (PRFA) procedure in renal cell carcinoma (RCC). METHODS From January 2008 to July 2010, 73 patients with sporadic unilateral RCC were enrolled to our study (57 men and 16 women, age range: 37-78 years, mean age 57.9 years). The diameter of the tumor was 1.7-5.8, 3.4 cm on average. The patients were divided into two groups depending on the intraoperative ultrasonography type: CEUS group and conventional ultrasound group. Patients in CEUS group received CEUS before insertion of the electrode, and the second CEUS was performed right after the initial ablation to dynamically evaluate the images. If there was highly suspicious residue, additional ablation and repeated CEUS were applied. Patients in the conventional ultrasound group received PRFA guided by gray-scale ultrasound. All of these patients received contrast-enhanced computed tomography (CT) examination 7 days after the procedure (patients in CEUS group received CEUS conducted with each CT scan), with subsequent CT and CEUS assessment at 3, 6, and every 6 months thereafter. RESULTS The mean follow-up period was 22 months (range: 12-42 months). All tumors were biopsied before RFA. The local tumor control rate was 94.6% (35/37) in the CEUS group and 86.1% (31/36) in the conventional ultrasound group (P < 0.05); the cancer-specific survival rate and the overall survival rate were 100%. The post-RFA (12 months) mean GFR levels were 84.7 ± 27.5 mL/min/1.73 m(2) (P > 0.05, compared with pre-GFR: 86.4 ± 26.2 mL/min/1.73 m(2)) in the CEUS group and 81.9 ± 22.8 mL/min/1.73 m(2) (P > 0.05, compared with pre-GFR: 83.5 ± 23.7 mL/min/1.73 m(2)) in the conventional ultrasound group. CONCLUSION Intraoperative CEUS can "real-time" monitor the ablated area during PRFA procedure. This technique can help to achieve a higher success rate compared with conventional ultrasound. No impact of intraoperative CEUS has been found on GFR level.
Collapse
|
25
|
Taibbi A, Bartolotta TV, Matranga D, Midiri M, Lagalla R. Splenic hemangiomas: contrast-enhanced sonographic findings. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2012; 31:543-553. [PMID: 22441910 DOI: 10.7863/jum.2012.31.4.543] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
OBJECTIVES The purpose of this study was to illustrate the baseline appearance and enhancement patterns of splenic hemangiomas on contrast-enhanced sonography. METHODS Two experienced radiologists retrospectively reviewed by consensus baseline and contrast-enhanced sonographic examinations of 27 patients (14 women and 13 men; mean age, 58.7 years) with 27 splenic hemangiomas (mean size, 2 cm) confirmed by splenectomy, biopsy, computed tomography, and magnetic resonance imaging and follow-up. RESULTS On baseline sonography, 77.8% of the lesions showed a homogeneous echo texture that was mainly hyperechoic. Color Doppler imaging did not show any signal in 81.5% of the cases. After contrast agent injection, 59.2% of the splenic hemangiomas showed different degrees of contrast enhancement in the arterial phase followed by isoenhancement in the late parenchymal phase. Among these, 2 hemangiomas showed peripheral globular enhancement in the arterial phase, followed by progressive centripetal fill-in. In 29.6% of the cases, some degree of contrast enhancement was appreciable, but the hemangiomas remained substantially hypoechoic throughout the contrast-enhanced sonographic examinations, whereas in 11.1%, the combination of contrast enhancement in the arterial phase followed by wash-out in the late parenchymal phase was evident. CONCLUSIONS Isoechogenicity to spleen parenchyma in all phases is the most frequent typical enhancement pattern of splenic hemangiomas observed on contrast-enhanced sonography. Nevertheless, these lesions may show atypical contrast enhancement patterns; therefore, further assessment with cross-sectional techniques is needed.
Collapse
Affiliation(s)
- Adele Taibbi
- Department of Radiology, University Hospital, Via Monti Iblei 43, 90144 Palermo, Italy.
| | | | | | | | | |
Collapse
|
26
|
Wu H, Patel RB, Zheng Y, Solorio L, Krupka TM, Ziats NP, Haaga JR, Exner AA. Differentiation of benign periablational enhancement from residual tumor following radio-frequency ablation using contrast-enhanced ultrasonography in a rat subcutaneous colon cancer model. ULTRASOUND IN MEDICINE & BIOLOGY 2012; 38:443-453. [PMID: 22266229 PMCID: PMC3280615 DOI: 10.1016/j.ultrasmedbio.2011.12.008] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/07/2011] [Revised: 12/02/2011] [Accepted: 12/06/2011] [Indexed: 05/31/2023]
Abstract
Benign periablational enhancement (BPE) response to thermal injury is a barrier to early detection of residual tumor in contrast enhanced imaging after radio-frequency (RF) ablation. The objective of this study was to evaluate the role of quantitative of contrast-enhanced ultrasound (CEUS) in early differentiation of BPE from residual tumor in a BD-IX rat subcutaneous colon cancer model. A phantom study was first performed to test the validity of the perfusion parameters in predicting blood flow of two US contrast imaging modes-contrast harmonic imaging (CHI) and microflow imaging (MFI). To create a simple model of BPE, a peripheral portion of the tumor was ablated along with surrounding normal tissue, leaving part of the tumor untreated. First-pass dynamic enhancement (FPDE) and MFI scans of CEUS were performed before ablation and immediately, 1, 4 and 7 days after ablation. Time-intensity-curves in regions of BPE and residual tumor were fitted to the function y = A(1-exp[-β{t-t0}])+C, in which A, β, t0 and C represent blood volume, flow speed, time to start and baseline intensity, respectively. In the phantom study, positive linear correlations were noted between A, β, Aβ and contrast concentration, speed and flow rate, respectively, in both CHI and MFI. On CEUS images of the in vivo study, the unenhanced ablated zone was surrounded by BPE and irregular peripheral enhancement consistent with residual tumor. On days 0, 4 and 7, blood volume (A) in BPE was significantly higher than that in residual tumor in both FPDE imaging and MFI. Significantly greater blood flow (Aβ) was seen in BPE compared with residual tumor tissue in FPDE on day 7 and in MFI on day 4. The results of this study demonstrate that qualitative CEUS can be potentially used for early detection of viable tumor in post-ablation assessment.
Collapse
Affiliation(s)
- Hanping Wu
- Department of Radiology, Case Western Reserve University, Cleveland, OH 44106, USA
| | | | | | | | | | | | | | | |
Collapse
|
27
|
Bartolotta TV, Taibbi A, Matranga D, Sandonato L, Asta S, Midiri M, Lagalla R. Incidence of new foci of hepatocellular carcinoma after radiofrequency ablation: role of multidetector CT. Radiol Med 2011; 117:739-48. [PMID: 22095421 DOI: 10.1007/s11547-011-0752-z] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2011] [Accepted: 03/31/2011] [Indexed: 12/20/2022]
Abstract
PURPOSE The authors sought to assess the incidence of new foci of hepatocellular carcinoma (HCC) using multidetector computed tomography (MDCT) in patients treated with radiofrequency ablation (RFA). MATERIALS AND METHODS Two readers retrospectively reviewed by consensus the follow-up MDCT studies of 125 patients (88 men and 37 women; mean age 68 years) with 141 HCCs (size 1-5.2 cm; mean 2.2 cm) treated with RFA. MDCT follow-up was performed at 1 and 3 months and every 6-12 months thereafter. Reviewers assessed: (1) the presence of new HCC foci in the same liver segment or in a different segment; (2) complete or incomplete tumour ablation; (3) tumour progression. RESULTS A total of 113 new HCCs (size 0.7-4.8 cm; mean 1.7 cm) were detected in 69/125 (55.2%) patients (mean follow-up 30.38±19.14 months). Of these, 86 (76.1%) new HCCs were multiple (p<0.0001), and 92 (81.4%) occurred in a different segment from that of the treated HCC (p<0.0001). New HCCs were observed in the first 12 months, between 12 and 24 months and after 24 months in 31/69 (44.9%), 24/69 (34.8%) and 14/69 (20.3%) patients, respectively (p=0.175). Mean diseasefree interval was 16.1±16.31 (range 1-52) months. Complete tumour ablation was achieved in 132/141 (93.6%) treated HCCs, and tumour progression occurred in 29/141 (20.6%) cases. CONCLUSIONS In patients with RFA-treated HCCs, MDCT follow-up revealed a high incidence of new HCCs, even after 1 year of follow-up. The new foci tended to be multiple and located in a liver segment different from that of the previously treated nodules.
Collapse
Affiliation(s)
- T V Bartolotta
- Department of Radiology, University of Palermo, Via Del Carabiniere 32, 90127, Palermo, Italy.
| | | | | | | | | | | | | |
Collapse
|
28
|
Application of contrast-enhanced ultrasonography after radiofrequency ablation for renal cell carcinoma: is it sufficient for assessment of therapeutic response? ACTA ACUST UNITED AC 2011; 36:342-7. [PMID: 21107560 DOI: 10.1007/s00261-010-9665-x] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
PURPOSE To assess the efficacy of contrast-enhanced ultrasonography (CEUS) with Sonovue in the evaluation of therapeutic response to radiofrequency ablation (RFA) of renal cell carcinoma (RCC). MATERIALS AND METHODS In a recent 3 years, 63 patients (mean age, 60 years; range 26-81 years) with 64 RCCs were treated by RFA. The lesions had a diameter between 1.8 and 9.8 cm (average diameter, 3.1 cm). The indications for RFA treatment included chronic renal insufficiency (n = 10), presence of solitary kidney (n =3), bilateral renal carcinoma (BRCC) (n =2), advanced age (n =12), significant medical comorbidity (n =29) or refusal of conventional therapy (n =7). Tumors were treated by laparoscopy-assisted (n =41), open surgical (n =18) or percutaneous US guidance (n =4). Follow-up CEUS and contrast-enhanced CT were performed 1 month after treatment to assess the necrotic area. Technical success was defined as elimination of areas that enhanced at imaging within the entire tumor. RESULTS On the 1-month CEUS and CT imaging after RFA, 62 of 64 tumors (96.9%) were successfully ablated with one session, and residual tumors were found in two RCCs. One of the two tumors was subjected to additional RFA treatment. We could not obtain a complete ablation in the other tumor of a patient with solitary kidney. The diagnostic concordance between the CEUS and 1-month follow-up CT was 100%. Sixty-one patients survived in the follow-up phase which ranged from 2 to 34 months. One patient with solitary kidney died of systemic disease progression and one patient was lost to follow-up. Of the 61 tumors without residual on both CT and CEUS after RFA, four had suspicious findings of recurrence on follow-up CEUS, and two of them were confirmed by subsequent CT examination. With CT as the reference imaging procedure in the assessment of renal tumor ablation, the sensitivity, specificity, positive predictive value, and negative predictive value of CEUS for detecting recurrence during follow-up were 100%, 96.6%, 50%, and 100%. CONCLUSION Despite its limitation of false-positive value, CEUS is potentially effective in assessing the therapeutic response to RFA of RCC.
Collapse
|
29
|
Treatment response assessment of radiofrequency ablation for hepatocellular carcinoma: usefulness of virtual CT sonography with magnetic navigation. Eur J Radiol 2011; 81:e277-80. [PMID: 21392916 DOI: 10.1016/j.ejrad.2011.02.026] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2011] [Accepted: 02/10/2011] [Indexed: 01/17/2023]
Abstract
PURPOSE Virtual CT sonography using magnetic navigation provides cross sectional images of CT volume data corresponding to the angle of the transducer in the magnetic field in real-time. The purpose of this study was to clarify the value of this virtual CT sonography for treatment response of radiofrequency ablation for hepatocellular carcinoma. PATIENTS AND METHODS Sixty-one patients with 88 HCCs measuring 0.5-1.3 cm (mean±SD, 1.0±0.3 cm) were treated by radiofrequency ablation. For early treatment response, dynamic CT was performed 1-5 days (median, 2 days). We compared early treatment response between axial CT images and multi-angle CT images using virtual CT sonography. RESULTS Residual tumor stains on axial CT images and multi-angle CT images were detected in 11.4% (10/88) and 13.6% (12/88) after the first session of RFA, respectively (P=0.65). Two patients were diagnosed as showing hyperemia enhancement after the initial radiofrequency ablation on axial CT images and showed local tumor progression shortly because of unnoticed residual tumors. Only virtual CT sonography with magnetic navigation retrospectively showed the residual tumor as circular enhancement. In safety margin analysis, 10 patients were excluded because of residual tumors. The safety margin more than 5 mm by virtual CT sonographic images and transverse CT images were determined in 71.8% (56/78) and 82.1% (64/78), respectively (P=0.13). The safety margin should be overestimated on axial CT images in 8 nodules. CONCLUSION Virtual CT sonography with magnetic navigation was useful in evaluating the treatment response of radiofrequency ablation therapy for hepatocellular carcinoma.
Collapse
|
30
|
Taibbi A, Furlan A, Sandonato L, Bova V, Galia M, Marin D, Cabibbo G, Soresi M, Bartolotta TV, Midiri M, Lagalla R, Brancatelli G. Imaging findings of liver resection using a bipolar radiofrequency electrosurgical device--initial observations. Eur J Radiol 2011; 81:663-70. [PMID: 21306849 DOI: 10.1016/j.ejrad.2011.01.015] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2010] [Accepted: 01/05/2011] [Indexed: 02/08/2023]
Abstract
OBJECTIVE To assess contrast-enhanced US (CEUS), computed tomography (CT) and magnetic resonance (MR) imaging findings and serial changes of the treated area at follow-up in patients who underwent liver resection using a bipolar radiofrequency electrosurgical device. METHODS Imaging findings of 27 patients with resected hepatocellular carcinomas (HCCs) (n=24) and metastases (n=3) (mean size: 2.6cm), were retrospectively evaluated. Two readers assessed: the (a) presence, (b) thickness, (c) shape and (d) echogenicity (CEUS)/attenuation (CT)/signal intensity (MR imaging) at coagulated site and the (e) presence of residual tumor of the bipolar radiofrequency electrosurgical device resection margin. RESULTS Follow-up was performed with either CT (n=20) or MR imaging (n=7) and repeated in 16 patients with CT (n=7), MR imaging (n=4), or both techniques (n=5). Four patients also had a single CEUS examination. At first imaging follow-up a peripheral halo was depicted at resection site (100%). A fluid collection within the surgical area was found in 67% of patients. During the following imaging examinations a progressive involution of both findings was observed, respectively, in 81% and 62% of patients. Viable tissue was detected in three patients (11%). CONCLUSIONS After liver resection with bipolar radiofrequency electrosurgical device successfully ablated tumor is demonstrated at imaging by an unenhancing partial linear peripheral halo, in most cases, surrounding a fluid collection reducing in size during follow-up.
Collapse
Affiliation(s)
- Adele Taibbi
- Department of Radiology, University of Palermo, Palermo, 90127, Italy.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
31
|
Li W, Tang J, Lv F, Zhang H, Zhang S, An L. Effectiveness and safety of CEUS-guided haemostatic injection for blunt splenic trauma: an animal experiment. Radiol Med 2010; 115:1080-6. [PMID: 20680497 DOI: 10.1007/s11547-010-0573-5] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2009] [Accepted: 08/06/2009] [Indexed: 12/27/2022]
Abstract
The aim of this study was to investigate whether complications occur after haemostatic agents are injected into blunt splenic injuries. After undergoing ultrasound (US), contrast-enhanced US (CEUS) and contrast-enhanced computed tomography (CECT) examinations, dogs with grade III-IV injury received the minimally invasive therapy. After treatment, CEUS was performed to observe changes in the regions treated. In the immediate group, dogs underwent laparotomy 30 min after treatment to observe the haemostatic effect. In the survival group, animals underwent CEUS and CECT examinations to observe the short-term healing outcome and complications at 3, 7, 14, and 21 days after the injection. After undergoing CEUS and CECT examinations, 12 dogs with grade III-IV injury received the minimally invasive therapy. Before injection, CEUS examinations showed anechoic and/or hypoechoic perfusion defects and active bleeding at the injury sites, and CECT showed traumatic lesions as low-density regions without enhancement. After treatment, CEUS demonstrated the disappearance of active bleeding, and hyperechoic spots emerged at the injury sites. Uneven density regions were displayed on CECT. Treated areas were covered by blood clots and glue membrane in the immediate-group animals. Three weeks later, CEUS showed a decrease of hyperechoic spots in the survival group, and the splenic parenchyma enhanced uniformly on CECT. Laparotomy showed that the greater omentum had moved upwards and partly covered the wound in four animals, and the injury sites had completely healed. Histopathological examination showed that fibrous connective tissue covered the splenic capsule and that the haemostatic glue had degraded. No complication occurred, such as delayed splenic haemorrhage, splenic abscesses, splenic pseudoaneurysms, intestinal obstruction or intestinal adhesions. CEUS-guided haemostatic injection is not only effective in stopping active bleeding immediately, but it is also safe in that no complications occurred during the 3 weeks of follow-up. This study indicates that CEUS-guided percutaneous injection may provide a safe, feasible and effective therapy for blunt splenic trauma.
Collapse
Affiliation(s)
- W Li
- Department of Ultrasound, Chinese People's Liberation Army General Hospital, 28 Fuxing Road, Beijing 100853, PR China
| | | | | | | | | | | |
Collapse
|
32
|
Characterisation of focal liver lesions undetermined at grey-scale US: contrast-enhanced US versus 64-row MDCT and MRI with liver-specific contrast agent. Radiol Med 2010; 115:714-31. [PMID: 20082225 DOI: 10.1007/s11547-010-0506-3] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2009] [Accepted: 05/07/2009] [Indexed: 12/27/2022]
Abstract
PURPOSE The aim of this study was to assess the role of contrast-enhanced ultrasonography (CEUS) in the characterisation of focal liver lesions in comparison with multidetector computed tomography (MDCT) and magnetic resonance imaging (MRI) with liver-specific contrast agent. MATERIALS AND METHODS One hundred and eighty-seven focal liver lesions, 91 malignant and 96 benign (mean size 3.2 cm) - proved by biopsy (n=12), histology (n=4), MDCT (n=108), MRI (n=44) MDCT/MRI (n=19) - in 159 patients were studied by CEUS. Two expert radiologists consensually evaluated the contrast-enhancement patterns at CEUS. For each lesion, they assessed: (a) nature (benign, malignant, not assessable), (b) specific diagnosis and (c) need for further radiological evaluation. Sensitivity, specificity, positive and negative predictive values and diagnostic accuracy of CEUS were calculated. RESULTS A total of 167/187 (89.3%) lesions were correctly assessed as benign or malignant at CEUS, whereas 14/187 (7.5%) lesions remained undetermined and 6/187 (3.2%) were incorrectly assessed. Sensitivity, specificity, positive and negative predictive values and diagnostic accuracy of CEUS were, respectively, 89%, 89.6%, 89%, 89.6% and 89.3%. The need for further radiological evaluation decreased to 46/187 (24.6%) lesions after CEUS (p<0.001). CONCLUSIONS In selected cases, CEUS can be considered an effective alternative to MDCT and MRI and reduce the need for further radiological workup.
Collapse
|
33
|
Gallotti A, D'Onofrio M, Ruzzenente A, Martone E, De Robertis R, Guglielmi A, Pozzi Mucelli R. Contrast-enhanced ultrasonography (CEUS) immediately after percutaneous ablation of hepatocellular carcinoma. Radiol Med 2009; 114:1094-105. [PMID: 19756947 DOI: 10.1007/s11547-009-0436-0] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2008] [Accepted: 03/19/2009] [Indexed: 12/16/2022]
Abstract
PURPOSE This study evaluated the effectiveness of contrast-enhanced ultrasound (CEUS), performed immediately after percutaneous ethanol injection (PEI) or radiofrequency thermal ablation (RFTA), by comparing results with the computed tomography (CT) follow-up. MATERIALS AND METHODS Sixty-nine consecutive patients with a diagnosis of hepatocellular carcinoma (HCC) were included in this prospective study. All patients underwent PEI or RFTA. After treatment, three CEUS enhancement patterns were observed: isovascular, hypovascular and avascular, which were compared with the CT findings. Sensitivity of the avascular pattern at CEUS and effectiveness of the ablative procedures were evaluated and compared with the chi-square test. RESULTS Ninety hypervascular HCCs, with a mean diameter of 2.6 cm (0.5-4.9 cm), underwent PEI (n=54) and RFTA (n=36). In the first group, CT identified complete necrosis in 28/54 (52%) lesions, 21 (75%) of which had avascular, one (4%) isovascular and six (21%) hypovascular patterns at CEUS. In the second group, CT showed complete necrosis in 31/36 (86%) lesions, all (100%) of which had a corresponding avascular pattern at CEUS. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy of the avascular pattern at CEUS compared with CT findings were 75%, 69%, 72%, 72% and 72% for PEI and 100%, 20%, 89%, 100% and 89%, for RFTA, respectively. A statistically significant difference (p<0.05) between the sensitivity of CEUS after PEI and after RFTA and between the necrosis obtained by RFTA and PEI were observed. CONCLUSIONS CEUS performed immediately after percutaneous ablation of hepatocellular carcinoma to evaluate treatment efficacy is compulsory in the case of RFTA but not for PEI.
Collapse
Affiliation(s)
- A Gallotti
- Istituto di Radiologia, Policlinico G.B. Rossi, Università di Verona, Verona, Italy
| | | | | | | | | | | | | |
Collapse
|
34
|
Pollard RE, Dayton PA, Watson KD, Hu X, Guracar IM, Ferrara KW. Motion corrected cadence CPS ultrasound for quantifying response to vasoactive drugs in a rat kidney model. Urology 2009; 74:675-81. [PMID: 19589583 DOI: 10.1016/j.urology.2009.01.086] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2008] [Revised: 01/12/2009] [Accepted: 01/27/2009] [Indexed: 12/13/2022]
Abstract
OBJECTIVE To establish the ability of contrast-enhanced motion corrected cadence pulse sequencing (CPS) to detect changes in renal blood flow induced by vasoactive substances in rats. METHODS Ultrasound contrast media was administered as a constant rate infusion into a phantom at a known rate and CPS data acquired. Rats were anesthetized and predrug CPS estimates of replenishment rate were made for the right kidney. Real-time motion correction was applied, and parametric images were generated from the CPS data. Group 1 rats (n = 7) were administered a vasodilator and group 2 rats (n = 3) were administered a vasoconstrictor. The CPS imaging of the kidney was repeated after ample time for drug effects to occur. RESULTS Contrast CPS accurately estimated flow velocity in the phantom model. In addition, CPS defined statistically significant differences between pre- and postdrug blood flow in the renal medulla (vasodilator, P < .01; vasoconstrictor, P < .0001) and cortex (vasoconstrictor, P < .0001). CONCLUSIONS We conclude that motion-corrected CPS ultrasound provides real-time quantification of renal blood flow alterations and may prove useful for the assessment of blood flow in transplanted kidneys.
Collapse
Affiliation(s)
- Rachel E Pollard
- Department of Surgical and Radiological Sciences, School of Veterinary Medicine, University of California, Davis, California 95616, USA.
| | | | | | | | | | | |
Collapse
|
35
|
Limitation for performing ultrasound-guided radiofrequency ablation of small renal masses. Eur J Radiol 2009; 75:248-52. [PMID: 19394181 DOI: 10.1016/j.ejrad.2009.03.050] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2008] [Revised: 01/22/2009] [Accepted: 03/03/2009] [Indexed: 01/20/2023]
Abstract
PURPOSE To evaluate which factor is involved in limiting ultrasound (US)-guided radiofrequency (RF) ablation of small renal masses. MATERIALS AND METHODS Twenty-five patients with 31 renal masses underwent image-guided RF ablation. If a lesion was visible on US, US-guided RF ablation was performed. If a lesion was invisible on US or if the lesion was incompletely ablated or recurred following US-guided RF ablation, CT-guided RF ablation was performed. We analyzed the various factors which were involved in US-guided RF ablation. RESULTS Of 31 masses, thirteen were US-visible lesions and underwent US-guided RF ablation whereas thirteen were US-invisible lesions and thus underwent CT-guided RF ablation. The remaining five lesions were US-visible but needed additional CT-guided RF ablation, due to incomplete ablation (n=4) or recurrence (n=1); these renal masses (3.1+/-1.0 cm) were significantly larger than those (1.8+/-0.6 cm) ablated with US alone (p<0.05). Steam bubbles (4.4 cm+/-0.7 cm) of the masses requiring additional CT-guided RF ablation were significantly larger than those (2.9 cm+/-0.7 cm) of the tumors completely ablated with US alone in size (p<0.05). CONCLUSIONS US-invisibility, lesion size, and steam bubbles may limit to perform US-guided RF ablation of small renal masses.
Collapse
|
36
|
|