1
|
Morgan S, Barriga J, Dadia S, Merose O, Sternheim A, Snir N. Three dimensional printing as an aid for pre-operative planning in complex cases of total joint arthroplasty: A case series. J Orthop 2022; 34:142-146. [PMID: 36072761 PMCID: PMC9441292 DOI: 10.1016/j.jor.2022.08.015] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Revised: 08/10/2022] [Accepted: 08/11/2022] [Indexed: 11/25/2022] Open
Abstract
Purpose Digital templating is an essential aspect of pre-operative planning for total joint arthroplasty procedures. For complex cases of joint reconstruction, the standard templating software is insufficient to achieve the desired accuracy. 3D printing significantly aids the pre-operative planning in complicated cases of joint reconstruction and offers immense potential towards improving outcomes in these cases. The purpose of the present study is to present the various ways in which 3D printing has aided our department in facilitating complex cases of lower extremity reconstruction. Methods Data was retrospectively retrieved for all patients that underwent total hip arthroplasty (THA) and total knee arthroplasty (TKA) with the aid of 3D printing technology at our institution between January 2016-February 2021. Patient pain was determined before and after surgery using the visual analogue scale (VAS). Patient reported outcome measures (PROMs) were additionally analyzed using the hip disability and osteoarthritis outcome score (HOOS) and knee injury and osteoarthritis outcome score (KOOS). Results The final study population consisted of 39 patients that underwent TKA or THA procedures with the use of 3D printing. Twenty-four (61.5%) of the surgeries in the study were THA procedures, whereas 15 (38.5%) were TKA procedures. The average VAS for patients reduced from 8.4% before surgery to 5.4% after surgery (p < 0.001). The mean KOOS of patients that underwent TKA was 17.33 ± 9.33 (43%) and the mean HOOS of patients that underwent THA was 13.79 ± 6.6 (42%). Conclusions The following series demonstrates the ability by which 3D printing facilitates complex cases of hip and knee reconstruction. 3D printing offers an improvement in understanding of patient specific anatomy, enhancing patient outcomes. Departments should consider the use of 3D printing technology as an adjunct when performing complex cases of lower extremity reconstruction.
Collapse
Affiliation(s)
- Samuel Morgan
- Sackler Faculty of Medicine, Tel Aviv University, Israel
| | - Juan Barriga
- Department of Orthopaedics, Tel Aviv Sourasky Medical Center and Sackler Faculty of Medicine, Israel
| | - Solomon Dadia
- Sackler Faculty of Medicine, Tel Aviv University, Israel
- National Unit of Orthopaedic Oncology, Tel Aviv Sourasky Medical Center and Sackler Faculty of Medicine, Israel
| | - Omri Merose
- Sackler Faculty of Medicine, Tel Aviv University, Israel
- National Unit of Orthopaedic Oncology, Tel Aviv Sourasky Medical Center and Sackler Faculty of Medicine, Israel
| | - Amir Sternheim
- Sackler Faculty of Medicine, Tel Aviv University, Israel
- National Unit of Orthopaedic Oncology, Tel Aviv Sourasky Medical Center and Sackler Faculty of Medicine, Israel
| | - Nimrod Snir
- Sackler Faculty of Medicine, Tel Aviv University, Israel
- Division of Adult Joint Reconstruction, Tel Aviv Sourasky Medical Center and Sackler Faculty of Medicine, Israel
| |
Collapse
|
2
|
Demographic Data Reliably Predicts Total Hip Arthroplasty Component Size. J Arthroplasty 2022; 37:S890-S894. [PMID: 35093541 DOI: 10.1016/j.arth.2022.01.051] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/09/2021] [Revised: 01/10/2022] [Accepted: 01/20/2022] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Preoperative radiographic templating for total hip arthroplasty (THA) has been shown to be inaccurate, although essential for streamlining operating room efficiency. Although demographic data have shown to predict total knee arthroplasty component sizes, the unique contour and design among femoral stem implants have limited a similar application for hip arthroplasty. The purpose of this study was to determine whether demographic data may predict cementless THA size independent of the stem design. METHODS A consecutive series of 1,653 index cementless metaphyseal-fitting THAs were reviewed between 2007 and 2019. This included 12 unique femoral component designs, 6 acetabular component designs, 60 femur size-design combinations, and 23 acetabular size-design combinations. Implanted component sizes and patient demographic data were collected, including gender, height, weight, laterality, age, race, and ethnicity. Multivariate linear regressions were formulated to predict implanted femur and acetabular component sizes from the demographic data. RESULTS There was a significant linear correlation between gender, implant model, age, height, and weight for femur (R2 = 0.778; P < .001) and acetabular (R2 = 0.491; P < .001) sizes. Calculated femur and acetabular component sizes averaged within 0.97 and 0.95 sizes of those implants, respectively. Femur and acetabular sizes were predicted within 1 size 79.1% and 78.2% and within 2 sizes 94.3% and 94.6% of the time, respectively. CONCLUSIONS Multivariate regression models were created based on specific demographics data to predict femur and acetabular component sizes. The model allows for simplified preoperative planning and potential cost savings implementation. A free phone application named EasyTJA was constructed for ease of implementation.
Collapse
|
3
|
Smith JBV, Bishi H, Wang C, Asopa V, Field RE, Sochart DH. The accuracy and reliability of preoperative digital 2D templating in prosthesis size prediction in uncemented versus cemented total hip arthroplasty: a systematic review and meta-analysis. EFORT Open Rev 2021; 6:1020-1039. [PMID: 34909222 PMCID: PMC8631246 DOI: 10.1302/2058-5241.6.210048] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
The purpose of this study was to compare the accuracy and the inter- and intra-observer reliability of preoperative digital 2D templating in prosthesis size prediction for the planning of cemented or uncemented THA. This study was registered in the NIHR PROSPERO database (ID: CRD42020216649) and conducted according to the PRISMA guidelines. A search of electronic databases in March 2021 found 29 papers overall. The quality of evidence was assessed using the IHE Quality Appraisal of Case Series Studies Checklist and the CASP Randomised Controlled Trials Checklist. A meta-analysis was conducted, and the accuracy was presented as proportions and the inter- and intra-observer reliability were measured using intraclass correlation coefficients (ICC). Accuracy within one prosthesis size (±1) for cemented stems was 0.89 (95% confidence interval (CI) 0.83–0.95), cemented cups 0.78 (95% CI 0.67–0.89), uncemented stems 0.74 (95% CI 0.66–0.82) and uncemented cups 0.73 (95% CI 0.67–0.79) (test of group differences: p = 0.010). Inter-observer reliability (ICC) for uncemented cups was 0.88 (95% CI 0.85–0.91), uncemented stems 0.86 (95% CI 0.81–0.91), cemented stems 0.69 (95% CI 0.54–0.84) and cemented cups 0.68 (95% CI 0.55–0.81) (test of group differences: p = 0.004). Due to lack of data, intra-observer reliability (ICC) could only be calculated for uncemented prostheses, which for the stems was 0.90 (95% CI 0.88–0.92) and for the cups was 0.87 (95% CI 0.83–0.90) (test of group differences: p = 0.124). The accuracy of preoperative digital templating is greater for cemented prostheses, but the inter-observer reliability is greater for uncemented prostheses. The intra-observer reliability showed a high level of agreement for uncemented prostheses.
Cite this article: EFORT Open Rev 2021;6:1020-1039. DOI: 10.1302/2058-5241.6.210048
Collapse
Affiliation(s)
- Joshua B V Smith
- Academic Surgical Unit, South West London Elective Orthopaedic Unit, Epsom, Surrey, UK
| | - Habeeb Bishi
- Academic Surgical Unit, South West London Elective Orthopaedic Unit, Epsom, Surrey, UK
| | - Chao Wang
- Kingston University and St George's University of London, Tooting, London, UK
| | - Vipin Asopa
- Academic Surgical Unit, South West London Elective Orthopaedic Unit, Epsom, Surrey, UK
| | - Richard E Field
- Academic Surgical Unit, South West London Elective Orthopaedic Unit, Epsom, Surrey, UK
| | - David H Sochart
- Academic Surgical Unit, South West London Elective Orthopaedic Unit, Epsom, Surrey, UK
| |
Collapse
|
4
|
Kristoffersson E, Otten V, Crnalic S. The accuracy of digital templating in cementless total hip arthroplasty in dysplastic hips. BMC Musculoskelet Disord 2021; 22:942. [PMID: 34758811 PMCID: PMC8582185 DOI: 10.1186/s12891-021-04793-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/06/2021] [Accepted: 10/15/2021] [Indexed: 11/18/2022] Open
Abstract
Background Total hip arthroplasty (THA) for developmental dysplasia of the hip (DDH) is a complex procedure due to associated anatomical abnormalities. We studied the extent to which preoperative digital templating is reliable when performing cementless THA in patients with DDH. Methods We templated and compared the pre- and postoperative sizes of the acetabular and femoral components and the center of rotation (COR), and analysed the postoperative cup coverage, leg length discrepancy (LLD), and stem alignment in 50 patients (56 hips) with DDH treated with THA. Results The implant size exactly matched the template size in 42.9% of cases for the acetabular component and in 38.2% of cases for the femoral component, whereas the templated ±1 size was used in 80.4 and 81.8% of cases for the acetabular and femoral components, respectively. There were no statistically significant differences between templated and used component sizes among different DDH severity levels (acetabular cup: p = 0.30 under the Crowe classification and p = 0.94 under the Hartofilakidis classification; femoral stem: p = 0.98 and p = 0.74, respectively). There were no statistically significant differences between the planned and postoperative COR (p = 0.14 horizontally and p = 0.52 vertically). The median postoperative LLD was 7 (range 0–37) mm. Conclusion Digital preoperative templating is reliable in the planning of cementless THA in patients with DDH.
Collapse
Affiliation(s)
- Emelie Kristoffersson
- Department of Surgical and Perioperative Sciences (Orthopaedics), Umeå University, 90185, Umeå, Sweden
| | - Volker Otten
- Department of Surgical and Perioperative Sciences (Orthopaedics), Umeå University, 90185, Umeå, Sweden
| | - Sead Crnalic
- Department of Surgical and Perioperative Sciences (Orthopaedics), Umeå University, 90185, Umeå, Sweden.
| |
Collapse
|
5
|
Holliday M, Steward A. Pre-operative templating for total hip arthroplasty: How does radiographic technique and calibration marker placement affect image magnification? J Med Radiat Sci 2021; 68:228-236. [PMID: 33590673 PMCID: PMC8424328 DOI: 10.1002/jmrs.461] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2020] [Accepted: 01/19/2021] [Indexed: 12/30/2022] Open
Abstract
INTRODUCTION Pre-operative templating using digital radiography is an effective method of planning for total hip arthroplasty (THA) and requires a generalised fixed magnification factor (MF) or external calibration markers (ECM). The effect on image magnification when changing source-to-image distance (SID), object-to-image distance (OID) and different imaging conditions is not well described. This study aims to quantify the range of effects manipulation of radiographic parameters can have on image magnification across different body habitus and imaging conditions. METHODS A simple phantom study was performed. A 25 mm ECM was placed at eight different OID values along the anterior-posterior phantom plane at three different SID values and imaging conditions, and X-rays were obtained. On each radiograph, the ECM was measured using a line calliper tool by three radiographers and recorded. The MF was calculated and recorded. RESULTS The smallest observed image MF was 1.16, for an 8 cm OID, 120 cm SID with the ECM placed within the central ray and the X-ray detector in bucky underneath the X-ray table. The largest image MF was 1.40 for a 15 cm OID, 100 cm SID with the X-ray detector placed underneath an emergency department imaging trolley. CONCLUSIONS Digital pre-operative templating for THA relies on accurate radiographic positioning and is dependent of the patient body habitus, radiographic parameters and imaging conditions selected by the radiographer. The use of appropriately positioned ECMs - placed medially between the patient's internally rotated legs at the level of the greater trochanter, lowers the potential for magnification inaccuracies.
Collapse
Affiliation(s)
- Mia Holliday
- Western HealthFootscrayVictoriaAustralia
- Deakin UniversityGeelongVictoriaAustralia
| | | |
Collapse
|
6
|
Shichman I, Factor S, Shaked O, Morgan S, Amzallag N, Gold A, Snir N, Warschawski Y. Effects of surgeon experience and patient characteristics on accuracy of digital pre-operative planning in total hip arthroplasty. INTERNATIONAL ORTHOPAEDICS 2020; 44:1951-1956. [PMID: 32699933 DOI: 10.1007/s00264-020-04733-4] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/18/2020] [Accepted: 07/14/2020] [Indexed: 01/28/2023]
Abstract
BACKGROUND The effect of surgeon experience on accuracy of digital pre-operative planning for total hip arthroplasty (THA) remains unclear. The aims of our study were to compare pre-operative planning accuracy between fellow-trained orthopaedic surgeons and residents and to explore whether surgery indication effects the prediction accuracy. METHODS We prospectively reviewed 101 patients who underwent pre-operative digital templating for THA in our center from January 2019 to January 2020 with King Mark device. Extracted data included baseline characteristics and indication for primary arthroplasty. Pre-operative digital templating was performed separately by both a fellow-trained surgeon and a resident. Accuracy of each group was compared with the implanted components. RESULTS The overall adequate pre-operative planning of the acetabular cup (exact or +/-1 size match) by the fellow-trained group was higher compared with the resident's group (77.2 and 64.3% respectively, p = 0.037), whereas the overall adequate pre-operative planning of the femoral stem (exact or +/-1 size match) was higher in the resident's group compared with the fellow-trained group (83.2 and 61.4% respectively, p < =0.001). The fellow-trained group showed better pre-operative planning of complex cases (developmental dysplasia of the hip and avascular necrosis of femoral head) than the resident's group. CONCLUSIONS The experience of the planner does not significantly affect the accuracy of correctly predicting component sizes. However, in complex cases, fellow-trained surgeons should assist residents in digital pre-operative templating for THA.
Collapse
Affiliation(s)
- Ittai Shichman
- Adult Reconstruction Unit, Division of Orthopedics, Sackler Faculty of Medicine, Tel Aviv Sourasky Medical Center,, Tel Aviv University, 6 Weizman Street, 6423906, Tel Aviv, Israel
| | - Shai Factor
- Adult Reconstruction Unit, Division of Orthopedics, Sackler Faculty of Medicine, Tel Aviv Sourasky Medical Center,, Tel Aviv University, 6 Weizman Street, 6423906, Tel Aviv, Israel
| | - Or Shaked
- Adult Reconstruction Unit, Division of Orthopedics, Sackler Faculty of Medicine, Tel Aviv Sourasky Medical Center,, Tel Aviv University, 6 Weizman Street, 6423906, Tel Aviv, Israel
| | - Samuel Morgan
- Adult Reconstruction Unit, Division of Orthopedics, Sackler Faculty of Medicine, Tel Aviv Sourasky Medical Center,, Tel Aviv University, 6 Weizman Street, 6423906, Tel Aviv, Israel
| | - Nissan Amzallag
- Adult Reconstruction Unit, Division of Orthopedics, Sackler Faculty of Medicine, Tel Aviv Sourasky Medical Center,, Tel Aviv University, 6 Weizman Street, 6423906, Tel Aviv, Israel
| | - Aviram Gold
- Adult Reconstruction Unit, Division of Orthopedics, Sackler Faculty of Medicine, Tel Aviv Sourasky Medical Center,, Tel Aviv University, 6 Weizman Street, 6423906, Tel Aviv, Israel
| | - Nimrod Snir
- Adult Reconstruction Unit, Division of Orthopedics, Sackler Faculty of Medicine, Tel Aviv Sourasky Medical Center,, Tel Aviv University, 6 Weizman Street, 6423906, Tel Aviv, Israel
| | - Yaniv Warschawski
- Adult Reconstruction Unit, Division of Orthopedics, Sackler Faculty of Medicine, Tel Aviv Sourasky Medical Center,, Tel Aviv University, 6 Weizman Street, 6423906, Tel Aviv, Israel.
| |
Collapse
|
7
|
Shi XT, Cheng CM, Feng CY, Li CF, Li SX, Liu JG. Crowe Type IV Hip Dysplasia Treated by THA Comebined with Osteotomy to Balance Functional Leg Length Discrepancy: A Prospective Observational Study. Orthop Surg 2020; 12:533-542. [PMID: 32167673 PMCID: PMC7189056 DOI: 10.1111/os.12655] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/27/2019] [Revised: 02/12/2020] [Accepted: 02/13/2020] [Indexed: 01/14/2023] Open
Abstract
Objective To measure the factors that affect functional leg length of Crowe type IV Developmental dysplasia of the hip (DDH) patients and to review our own methods to balance leg length discrepancy (LLD) in Crowe type IV DDH patients. Methods This was a prospective observational study which started in June 2017 and ended in August 2019. Inclusion criteria included: (i) Crowe type I or Crowe type IV hip dysplasia patients who underwent total hip arthroplasty (THA) in the Department of Orthopaedics at our institution between July 2017 and June 2018; (ii) the patients were treated with our specific leg length balance strategy; and (iii) the related outcomes of patients were completely recorded. Finally, 18 consecutive Crowe type I patients (20 hips) and 14 consecutive Crowe type IV patients (18 hips) were selected and divided into two groups according to Crowe types. All patients received THA, and patients with a longer affected side and inferior anatomical acetabular positions in Crowe type IV group also received subtrochanteric osteotomy. During operation and after hip reduction, leg lengths were compared while two legs were in an extended position and the operative leg was on top of the non‐operative one. Additional leg length adjustment was applied when leg length was considered to be unequal. Prior to surgery, subluxation height of the femoral head on the affected side, functional LLD, bony length of lower limbs, and distance from teardrops to the lowest point line of the sacroiliac joint were recorded. After surgery, cup sizes, functional LLD, and height of hip rotational centers were measured. Clinical evaluations, such as Harris Hip Score (HHS) and SF‐12 scale, were also obtained before and after surgery for all patients. Results At the last follow‐up, functional LLD and clinical measurements of both Crowe type IV group and Crowe type I group were significantly improved. Compared with Crowe type I patients, Crowe type IV patients had a significantly lower MCS, a significantly longer leg lengthening length and a significantly lower hip center height after surgery. Significant differences of tibia length, leg length, and teardrop position were found between affected side and healthy side of Crowe type IV patients. Only three of 14 Crowe type IV patients remained under 1 cm functional LLD. Five patients in the Crowe type IV group developed lower limb numbness immediately following surgery, and they all recovered within 6 months. The average follow‐up period for either group was 14 months, and all patients were followed‐up at 1, 3, 6, and 12 months then yearly after surgery until the final follow‐up. Conclusion After detailed leg length balance process, THA combined with transverse sub‐trochanter osteotomy could be an effective method to achieve equal function leg length with most Crowe type IV patients.
Collapse
Affiliation(s)
- Xiao-Tong Shi
- Department of Orthopaedics, Ji Lin University First Hospital, Changchun, China
| | - Cheng-Ming Cheng
- Department of Orthopaedics, Ji Lin University First Hospital, Changchun, China
| | - Chun-Yang Feng
- Department of Gynecology, Ji Lin University Second Hospital, Changchun, China
| | - Chao-Feng Li
- Department of Orthopaedics, Ji Lin University First Hospital, Changchun, China
| | - Shu-Xuan Li
- Department of Orthopaedics, Ji Lin University First Hospital, Changchun, China
| | - Jian-Guo Liu
- Department of Orthopaedics, Ji Lin University First Hospital, Changchun, China
| |
Collapse
|
8
|
Shi XT, Li CF, Cheng CM, Feng CY, Li SX, Liu JG. Preoperative Planning for Total Hip Arthroplasty for Neglected Developmental Dysplasia of the Hip. Orthop Surg 2019; 11:348-355. [PMID: 31197911 PMCID: PMC6595139 DOI: 10.1111/os.12472] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/30/2019] [Revised: 05/05/2019] [Accepted: 05/12/2019] [Indexed: 12/12/2022] Open
Abstract
Developmental dysplasia of the hip (DDH) is accompanied by morphological alterations on both the acetabular and the femoral side. Total hip arthroplasty (THA) provides effective treatment in cases of neglected DDH but requires elaborate preoperative planning. To determine the morphological changes resulting from the dysplasia, the anatomic acetabular position, the height of the femur head dislocation, the height of the femur head dislocation, and the combined anteversion must all be established. In addition, a vital and complicated process of strategizing leg length balance must be conducted in cases of severe DDH. Each type of leg length discrepancy (LLD), including bony and functional and anatomical LLD, should be evaluated in the context of the presence or absence of a fixed pelvic tilt. Moreover, with severe unilateral dislocated hips, a more inferior change in the original rotational center of the hip must be accounted for. Due to these multiple morphological changes, the accurate size of the prosthesis and the cup position are difficult to predict. In comparison with other methods, CT scan‐based 3‐dimensional templating provides the best accuracy. Despite the presence of anatomic alterations, various types of acetabular and femoral prostheses have been developed to treat hip dysplasia. Both cemented and cementless cups are used in DDH cases. In DDH accompanied by insufficient acetabular bone stock, a cemented cup combined with bone graft provides a reliable treatment. Monoblock stems can be used when the combined anteversion is less than 55°, and a modular stem system when this parameter is greater than 55°. Customized stems can be designed for DDH coupled with severe proximal femoral distortion. A ceramic‐on‐ceramic bearing is considered optimal for young DDH patients.
Collapse
Affiliation(s)
- Xiao-Tong Shi
- Department of Orthopaedics, Jilin University First Hospital, Changchun, China
| | - Chao-Feng Li
- Department of Orthopaedics, Jilin University First Hospital, Changchun, China
| | - Cheng-Ming Cheng
- Department of Orthopaedics, Jilin University First Hospital, Changchun, China
| | - Chun-Yang Feng
- Department of Gynecology, Jilin University Second Hospital, Changchun, China
| | - Shu-Xuan Li
- Department of Orthopaedics, Jilin University First Hospital, Changchun, China
| | - Jian-Guo Liu
- Department of Orthopaedics, Jilin University First Hospital, Changchun, China
| |
Collapse
|
9
|
Alnahhal A, Aslam-Pervez N, Sheikh HQ. Templating Hip Arthroplasty. Open Access Maced J Med Sci 2019; 7:672-685. [PMID: 30894933 PMCID: PMC6420946 DOI: 10.3889/oamjms.2019.088] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2018] [Revised: 01/07/2019] [Accepted: 01/08/2019] [Indexed: 12/16/2022] Open
Abstract
BACKGROUND: Different methods have been developed and employed with variable degrees of success in pre-operative templating for total hip arthroplasty. Preoperative templating, especially digital templating, has been claimed to have increased the effectiveness of total hip arthroplasty by improving the precision of prediction of prosthetic implant size. AIMS: The overall aim of this systematic review is to identify whether the use of pre-operative templating in total hip arthroplasty procedures has resulted in increased accuracy, reliability and precision of the procedure. Various methods of templating, like traditional acetate overlay and digital method of templating that includes a single radiographic marker and double radiographic marker methods, have been compared to establish the most reliable method of templating. METHODS: We searched the PubMed, Google Scholar Cochrane Central Register of Controlled Trials (CENTRAL), and MEDLINE (1966 to present), EMBASE (1980 to present), CINAHL (1982 to present), Psych INFO (1967 to present) and Clinical Trials Gov. CONCLUSION: The results of this systemic review suggest that preoperative templating is resulting in an enormous increase in the accuracy of total hip arthroplasty and among various methods, King Mark is the most reliable method.
Collapse
Affiliation(s)
- Amro Alnahhal
- Barnsley District General Hospital NHS Trust, Gawber Road Barnsley S75 2EP, Great Britain
| | - Nayef Aslam-Pervez
- Calderdale and Huddersfield NHS trust, Acre St, Huddersfield HD3 3EA, Great Britain
| | | |
Collapse
|
10
|
Novel technique for intraoperative sciatic nerve assessment in complex primary total hip arthroplasty: a pilot study. Hip Int 2018; 28:210-217. [PMID: 29027186 DOI: 10.5301/hipint.5000553] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
INTRODUCTION Sciatic nerve injury (SNI) is a potentially devastating complication after total hip arthroplasty (THA). Intraoperative neural monitoring has been found in several studies to be useful in preventing SNI, but can be difficult to implement. In this study, we examine the results of using a handheld nerve stimulator for intraoperative sciatic nerve (SN) monitoring during complex THA requiring limb lengthening and/or significant manipulation of the SN. METHODS A consecutive series of 11 cases (9 patients, 11 hips) with either severe developmental dysplasia of the hip (Crowe 3-4) or other underlying conditions requiring complex hip reconstruction involving significant leg lengthening and/or nerve manipulation. SN function was monitored intraoperatively by obtaining pre- and post-reduction thresholds during component trialing. The results of nerve stimulation were then used to influence intraoperative decision-making. RESULTS No permanent postoperative SN complications occurred, with an average increase of 28.5 mm in limb length, range (6-51 mm). In 2 out of 11 cases, a change in nerve response was identified after trial reduction, which resulted in an alternate surgical plan (femoral shortening osteotomy and downsizing femoral head). In the remaining cases, the stimulator demonstrated a response consistent with the baseline assessment, assuring that the appropriate lengthening was achieved without SNI. 1 patient had a transient motor and sensory peroneal nerve palsy, which resolved within 2 weeks. CONCLUSIONS The intraoperative use of a handheld nerve stimulator facilitates surgical decision-making and can potentially prevent SNI. The real-time assessment of nerve function allows immediate corrective action to be taken before nerve injury occurs.
Collapse
|
11
|
Ogawa T, Takao M, Sakai T, Sugano N. Factors related to disagreement in implant size between preoperative CT-based planning and the actual implants used intraoperatively for total hip arthroplasty. Int J Comput Assist Radiol Surg 2017; 13:551-562. [DOI: 10.1007/s11548-017-1693-3] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2016] [Accepted: 12/06/2017] [Indexed: 12/20/2022]
|
12
|
Abstract
BACKGROUND When performing total hip arthroplasty (THA) on a dysplastic hip, proper positioning of the acetabular component may not allow for more than 70% coverage. Structural support in the form of an autograft or a high porosity metal augment may be necessary. The purpose of the study was to investigate the value of preoperative templating and deformity classification in predicting cup coverage and the need for structural support. METHODS 65 cases of THA for DDH were retrospectively analysed. 2 observers independently classified each dysplastic hip according to Hartofilakidis and determined the extent of cup coverage via templating software on preoperative digital AP pelvic radiographs. RESULTS Weighted kappa interobserver agreement was 0.68 for cup coverage and 0.76 for Hartofilakidis type. Structural support was necessary in 10 hips. No structural support was necessary in Hartofilakidis type 1, dysplasia cases. However, 27-30% of cases with type 2 or type 3 dysplasia required structural support. All cases with templated cup coverage of 65% or less required structural support. Templated coverage within 65-75% and over 75% resulted in 20% and 10% of patients receiving structural augmentation, respectively. CONCLUSIONS Preoperative planning for THA in the setting of hip dysplasia is crucial and can provide valuable insight to the need for column augmentation. However, the 3-D severity of the deformity may be underestimated in the 2-D radiographs.
Collapse
|
13
|
The Utility of a Digital Virtual Template for Junior Surgeons in Pedicle Screw Placement in the Lumbar Spine. BIOMED RESEARCH INTERNATIONAL 2016; 2016:3076025. [PMID: 27314013 PMCID: PMC4893428 DOI: 10.1155/2016/3076025] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/07/2016] [Accepted: 04/17/2016] [Indexed: 12/03/2022]
Abstract
This study assessed the utility of three-dimensional preoperative image reconstruction as digital virtual templating for junior surgeons in placing a pedicle screw (PS) in the lumbar spine. Twenty-three patients of lumbar disease were operated on with bilateral PS fixation in our hospital. The two sides of lumbar pedicles were randomly divided into “hand-free group” (HFG) and “digital virtual template group” (DVTG) in each patient. Two junior surgeons preoperatively randomly divided into these two groups finished the placement of PSs. The accuracy of PS and the procedure time of PS insertion were recorded. The accuracy of PS in DVTG was 91.8% and that in HFG was 87.7%. The PS insertion procedure time of DVTG was 74.5 ± 8.1 s and that of HFG was 90.9 ± 9.9 s. Although no significant difference was reported in the accurate rate of PS between the two groups, the PS insertion procedure time was significantly shorter in DVTG than in HFG (P < 0.05). Digital virtual template is simple and can reduce the procedure time of PS placement.
Collapse
|
14
|
Zeng Y, Lai OJ, Shen B, Yang J, Zhou ZK, Kang PD, Pei FX, Zhou X. Three-dimensional computerized preoperative planning of total hip arthroplasty with high-riding dislocation developmental dysplasia of the hip. Orthop Surg 2015; 6:95-102. [PMID: 24890290 DOI: 10.1111/os.12099] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/05/2013] [Accepted: 02/28/2014] [Indexed: 02/05/2023] Open
Abstract
OBJECTIVE To assess whether computed tomography (CT)-based 3-dimensional (3D) computerized pre-operative planning is accurate and reliable in patients with high-riding dislocation developmental dysplasia of the hip (DDH) undergoing total hip arthroplasty (THA). METHODS Between September 2009 and February 2011, a prospective study with an inbuilt means of comparing predictive techniques in 20 patients (20 hips) with high-riding dislocation DDH was undertaken. All patients had pre- and post-operative CT scans, data from which were transferred digitally to Mimics software. 3D pre-operative planning to predict the acetabular component size, hip rotation center position and acetabular component coverage was performed using Mimics software. The results and post-operative course were compared with those of the traditional acetate templating technique. RESULTS Using 3D computerized planning, 14/20 components (70%) were predicted exactly and 6/20 (30%) within one size, whereas with the conventional acetate templating technique, 5/20 components (25%) were predicted exactly, 9/20 (45%) within one size and 6/20 (30%) within two or more sizes. There was a strong correlation between the 3D computerized planned acetabular component size, hip rotation center distance, acetabular component host coverage and that found postoperatively. Five patients were considered to need structural bone graft on the basis of 3D computerized planning; this was highly coincident with the intraoperative findings in all five cases. CONCLUSION CT-based 3D computerized pre-operative planning using Mimics software is an accurate and reliable technique for patients with high-riding dislocation DDH undergoing THA.
Collapse
Affiliation(s)
- Yi Zeng
- Department of Orthopaedic Surgery, West China Hospital, West China Medical School, Sichuan University, Chengdu, China
| | | | | | | | | | | | | | | |
Collapse
|
15
|
Siddiqui NA, Lamm BM. Digital planning for foot and ankle deformity correction: Evans osteotomy. J Foot Ankle Surg 2014; 53:700-5. [PMID: 24909804 DOI: 10.1053/j.jfas.2014.04.011] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/14/2013] [Indexed: 02/03/2023]
Abstract
Preoperative planning is commonly performed for many foot and ankle procedures. The purpose of the present study was to prospectively determine the preoperative digital planning accuracy of predicting the calcaneal graft size used during the "Evans" calcaneal osteotomy. Preoperative digital deformity correction planning, using a standard planning method (TraumaCad(®) software), was performed on 10 feet scheduled to undergo an Evans procedure. Of the 10 patients, 6 were female and 4 were male, with an average age of 43 ± 22 years. Digital planning was used to predict the Evans graft size. The surgeon was unaware of the predicted graft size, which was then compared with the actual graft size inserted during the procedure. In addition, the pre- and postoperative radiographic angles were recorded and compared (anteroposterior view, talo-first metatarsal angle, calcaneocuboid abduction; lateral view, calcaneal inclination angle; and axial view, tibial-calcaneal angle). The average preoperative talo-first metatarsal angle, calcaneocuboid angle, calcaneal inclination angle, and tibial-calcaneal angle measured 21° ± 9.6°, 28.3° ± 9.0°, 13.8° ± 5.7°, and 15.3° ± 8.2°, respectively. The preoperative tibial-calcaneal position was 2.8 ± 1.2 mm. The radiographic weightbearing angles measured at an average follow-up of 7.4 (range 6 to 12) months improved to 6.3° ± 7.4° (p = .0015), 12.3° ± 6.1° (p < .001), 21.3° ± 7.7° (p = .0122), and 2.2° ± 3.6° (p = .0019) for the talo-first metatarsal, calcaneocuboid abduction, calcaneal inclination, and tibial-calcaneal angles, respectively. The final tibial-calcaneal position measured 1.4 ± 0.7 mm (p < .001). The preoperative Evans graft measurement (11.8 ± 2.6 mm) compared with the actual graft (12.2 ± 1.3 mm) placed was within 0.4 ± 1.8 mm (p = .51). Preoperative digital planning for Evans calcaneal osteotomy has been shown to be a valuable tool for predicting the surgical graft size for accurate pedal realignment.
Collapse
Affiliation(s)
- Noman A Siddiqui
- Chief of Podiatry, Northwest Hospital, and Medical Director, Diabetic Limb Preservation, LifeBridge Health, International Center for Limb Lengthening, Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, Baltimore, MD.
| | - Bradley M Lamm
- Chief, Diabetic Limb Preservation, LifeBridge Health, Head of Foot and Ankle Surgery, and Director, Foot and Ankle Deformity Correction Fellowship, International Center for Limb Lengthening, Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, Baltimore, MD
| |
Collapse
|
16
|
Kniesel B, Konstantinidis L, Hirschmüller A, Südkamp N, Helwig P. Digital templating in total knee and hip replacement: an analysis of planning accuracy. INTERNATIONAL ORTHOPAEDICS 2013; 38:733-9. [PMID: 24162155 DOI: 10.1007/s00264-013-2157-1] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/02/2013] [Accepted: 10/11/2013] [Indexed: 02/07/2023]
Abstract
PURPOSE The aim of this study was to determine how well pre-operative size selection for total knee and hip arthroplasties based on the digital imaging with and without additional referencing correlated with the size actually implanted. METHODS Size selection planning of total knee arthroplasty by digital templating was documented in 46 cases with reference ball (group A) and in 48 cases without ball (group B). In addition, prospective analysis of pre-operative planning was conducted for 52 acetabular components with reference ball (group C) and 69 without ball (group D) as well as stem planning in 38 cases with ball (group E) and 54 cases without ball (group F). The data were analysed and compared with the size of the final component selected during surgery. RESULTS The correlation between planned and implanted size for total knee arthroplasty in group A resulted in femoral anteroposterior (AP) r = 0.8622 and lateral r = 0.8333 and in group B AP r = 0.4552 and lateral r = 0.6950. Tibial in group A was AP r = 0.9030 and lateral r = 0.9074 and in group B AP r = 0.7000 and lateral r = 0.6376. For the acetabular components, the results in group C were r = 0.5998 and group D r = 0.6923. For stems, group E was r = 0.5306 and group F r = 0.5786. No correlation between BMI and the difference between planned and implanted size was found in any of the groups. CONCLUSION In the case of total hip arthroplasty there was a relatively low correlation between planned and implanted sizes with or without reference ball. For total knee arthroplasties the already high precision of size planning was further improved by the additional referencing with a reference ball.
Collapse
Affiliation(s)
- Bettina Kniesel
- Clinic for Orthopaedic and Trauma Surgery, Hospital Bad Cannstatt, Prießnitzweg 24, 70374, Stuttgart, Germany,
| | | | | | | | | |
Collapse
|
17
|
The ratio of femoral head diameter to pelvic height in the normal hips of a Chinese population. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY 2013; 24:947-51. [PMID: 23979044 DOI: 10.1007/s00590-013-1298-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/14/2013] [Accepted: 07/21/2013] [Indexed: 01/13/2023]
Abstract
OBJECTIVE The aim of this study was to determine whether the ratio between the femoral head diameter and pelvic height in a Chinese population is the same as that found in Westerners. MATERIALS AND METHODS Standard pelvic radiography was performed on a group of 187 Chinese adult subjects consisting of 81 males and 106 females with a mean age of 40 years (21-68 years). Femoral head diameter (vertical distance from the femoral head-neck junction to the highest point of the femoral head) and pelvic height (vertical distance from the highest point of the iliac crest to the edge of the ischial tuberosities) were measured. RESULTS There were significant differences between males and females (p < 0.001), and between persons of high height versus low height (p = 0.011) and medium height (p = 0.039). There were no significant differences between persons of different age (p = 0.244), body mass index (p = 0.091), or between persons of low- and medium-height groups (p = 0.69). The overall mean ratio between the femoral head diameter and pelvic height was 0.215 (0.173-0.249) with a 95 % CI = 0.214-0.217. The mean ratios in males and females were 0.221 (0.194-0.249) and 0.211 (0.173-0.238), respectively. CONCLUSION The mean ratio in Chinese population was similar to the reported ratio in a western population (about 1:5). We suggest that Chinese surgeons may be able to use the Crowe classification to classify patients with hip dysplasia.
Collapse
|
18
|
Validity and reliability of preoperative templating in total hip arthroplasty using a digital templating system. Skeletal Radiol 2012; 41:1245-9. [PMID: 22588597 DOI: 10.1007/s00256-012-1431-4] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/28/2012] [Revised: 04/17/2012] [Accepted: 04/23/2012] [Indexed: 02/06/2023]
Abstract
OBJECTIVES To evaluate the validity, interobserver reliability, and intraobserver reproducibility of a digital templating system, the Mdesk™ in preoperative templating in cemented and reverse hybrid total hip arthroplasty (THA). MATERIALS AND METHODS Validity was evaluated by comparing the planned cup size, stem size, CCD angles, and neck length with the components used in 129 patients operated with cemented and reverse hybrid THA. The reliability was measured by comparing the templating results of two surgeons with each other (interobserver) and the results of two templatings carried out by first surgeon (intraobserver). The leg length discrepancy was measured before and after the operation to assess the templating ability to correct it. RESULTS The Mdesk™ system showed good validity (kappa value ranged from 0.64 to 0.96), especially when one size over and under the planned size were included. No difference between cemented and cementless stems was found. The interobserver reliability ranged from fair (kappa 0.23) to substantial (kappa 0.61) while the intraobserver reproducibility ranged from substantial (kappa 0.70) to excellent (kappa 0.82). Templating and intraoperative measures succeeded to restore the leg length. CONCLUSIONS The Mdesk™ system has comparable validity and reliability with other templating systems used in clinical practice. We recommend that the same surgeon who does the preoperative radiographic templating to also perform the operation. Further studies are required to evaluate the results of succeeded templating in the long run.
Collapse
|
19
|
Schmidutz F, Steinbrück A, Wanke-Jellinek L, Pietschmann M, Jansson V, Fottner A. The accuracy of digital templating: a comparison of short-stem total hip arthroplasty and conventional total hip arthroplasty. INTERNATIONAL ORTHOPAEDICS 2012; 36:1767-72. [PMID: 22476451 DOI: 10.1007/s00264-012-1532-7] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/02/2012] [Accepted: 03/14/2012] [Indexed: 12/31/2022]
Abstract
PURPOSE Selection of the correct femoral stem size is crucial in total hip arthroplasty for an uncomplicated implantation and good initial stability. Pre-operative templating has been shown to be a valuable tool in predicting the correct implant size. For short-stem total hip arthroplasty (SHA), which recently is increasingly used, it is unknown if templating can be performed as reliable as conventional total hip arthroplasty (THA). METHODS A total of 100 hip arthroplasties, 50 with SHA and 50 with THA, were templated by four orthopaedic surgeons each. The surgeons had different levels of professional experience and performed a digital template of the acetabular and femoral component on the pre-operative radiographs. The results were compared with the truly inserted implant size. RESULTS For the femoral stems the average percentage of agreement (± 1 size) was 89.0 % in SHA and 88.5 % in THA. There was no significant difference among surgeons in the accuracy of templating the correct stem size and no significant difference between templating SHA and THA. For the acetabular component the average percentage of agreement (± 1 size) was 75.8 %. However, the more experienced surgeons showed a significant higher accuracy for templating the correct cup size than the less experienced surgeons. CONCLUSION Digital templating of SHA can predict the stem sizes as accurately as conventional THA. Therefore digital templating is also recommendable for SHA, as it helps to predict the implant size prior to surgery and thereby might help to avoid complications.
Collapse
Affiliation(s)
- Florian Schmidutz
- Department of Orthopaedic Surgery, Campus Grosshadern, University Hospital of Munich, LMU, Munich, Germany.
| | | | | | | | | | | |
Collapse
|
20
|
Hsu AR, Kim JD, Bhatia S, Levine BR. Effect of training level on accuracy of digital templating in primary total hip and knee arthroplasty. Orthopedics 2012; 35:e179-83. [PMID: 22310403 DOI: 10.3928/01477447-20120123-15] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
The use of digital radiography and templating software continues to become more prevalent in orthopedics as the number of total hip arthroplasty (THA) and total knee arthroplasty (TKA) procedures increases every year. The purpose of this study was to evaluate the effect of training level on the accuracy of digital templating for primary THA and TKA. Digital radiographs of 97 patients undergoing primary THA (49 cases) and TKA (48 cases) were retrospectively templated using OrthoView digital planning software (OrthoView LLC, Jacksonville, Florida). Anteroposterior hip and lateral knee radiographs were digitally templated and compared with the actual size of the implants used intraoperatively. An implant sales representative, physician assistant, medical student (J.D.K.), resident (A.R.H.), and fellowship-trained arthroplasty surgeon (B.R.L.) templated all cases independently after a standardized orientation and were blinded to the actual component sizes used for surgery. The medical student, resident, and arthroplasty surgeon retemplated the same 97 cases 1 month later to determine intraobserver reliability. Digital templating was accurate in predicting the correct implant size in 33% of THAs and 54% of TKAs. In 73% of THAs and 92% of TKAs, digital templating was within 1 size of the actual implant used, and in 88% of THAs and 99% of TKAs, templating was within 2 sizes of the final components. In no cases did the templated implant size vary by >3 sizes from the final components. Interobserver reliability for templating THAs and TKAs showed good reliability as measured by intraclass correlation coefficient (ICC) (ICC(THA)=.70; ICC(TKA)=.86). Intraobserver reliability for templating THAs had excellent reliability for the resident and arthroplasty surgeon, with a kappa coefficient (κ) of 0.92, and good reliability for the medical student (κ=0.78). Intraobserver reliability for templating TKAs showed excellent reliability among all examiners (κ=0.90).
Collapse
Affiliation(s)
- Andrew R Hsu
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois, USA
| | | | | | | |
Collapse
|
21
|
Zhao X, Zhu ZA, Xie YZ, Yu B, Yu DG. Total hip replacement for high dislocated hips without femoral shortening osteotomy. ACTA ACUST UNITED AC 2011; 93:1189-93. [PMID: 21911529 DOI: 10.1302/0301-620x.93b9.25914] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
When performing total hip replacement (THR) in high dislocated hips, the presence of soft-tissue contractures means that most surgeons prefer to use a femoral shortening osteotomy in order to avoid the risk of neurovascular damage. However, this technique will sacrifice femoral length and reduce the extent of any leg-length equalisation. We report our experience of 74 THRs performed between 2000 and 2008 in 65 patients with a high dislocated hip without a femoral shortening osteotomy. The mean age of the patients was 55 years (46 to 72) and the mean follow-up was 42 months (12 to 78). All implants were cementless except for one resurfacing hip implant. We attempted to place the acetabular component in the anatomical position in each hip. The mean Harris hip score improved from 53 points (34 to 74) pre-operatively to 86 points (78 to 95) at final follow-up. The mean radiologically determined leg lengthening was 42 mm (30 to 66), and the mean leg-length discrepancy decreased from 36 mm (5 to 56) pre-operatively to 8.5 mm (0 to 18) postoperatively. Although there were four (5%) post-operative femoral nerve palsies, three had fully resolved by six months after the operation. No loosening of the implant was observed, and no dislocations or infections were encountered. Total hip replacement without a femoral shortening osteotomy proved to be a safe and effective surgical treatment for high dislocated hips.
Collapse
Affiliation(s)
- X Zhao
- Ninth People's Hospital, Shanghai JiaoTong University School of Medicine, Shanghai Key Laboratory of Orthopaedic Implant, 639 Zhizaoju Road, Shanghai 200011, China
| | | | | | | | | |
Collapse
|
22
|
Custom total hip arthroplasty in skeletal dysplasia. INTERNATIONAL ORTHOPAEDICS 2011; 36:527-31. [PMID: 21751022 DOI: 10.1007/s00264-011-1314-7] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/27/2011] [Accepted: 06/20/2011] [Indexed: 10/18/2022]
Abstract
PURPOSE Osteochondrodysplasias are characterised by aberrant cartilage and bone development; consequently, patients may be subject to premature hip degeneration. In this population hip arthroplasty outcomes are variable. This series reviews the use of custom femoral implants in total hip replacements for patients with severe skeletal dysplasia. METHODS We reviewed 14 hips in nine patients with genetic dwarfism. Computed tomography (CT) scans of the pelvis and femurs were used to create custom titanium stems. Postoperative radiographs were reviewed for migration, osteolysis, fracture and restoration of leg length. Pre- and postoperative Harris hip scores (HHS) were compared, with a mean follow-up of 36.3 months. Mean age was 36.5 years (range 15-50 years) and mean height was 48 inches (range 42-55 inches). Three joints were classified as Crowe type I, two type II, three type III and six type IV. RESULTS Three hips (21%) required revision: two for stem migration and one for acetabular osteolysis. Eleven hips (79%) were stable with signs of osseointegration. No fractures, nerve damage or dislocations occurred. Two stems required cement fixation, and no liners were constrained. Significant osteolysis was seen on three radiographs. All patients walked independently, and mean HHS improved from 45 (24-58) to 71 (47-89). All leg length discrepancies were restored to within 3 mm of equal. CONCLUSIONS This study reports good midterm outcomes in a variety of skeletal dysplasias, thus confirming the efficacy of custom femoral implants in the management of this patient group.
Collapse
|