1
|
Baid M, Hait S, Daga S, Das A, Kumar Mandal A, Sam J, Dhandapani K, Amjad A, D'sa P. Arthroscopic Reconstruction of an Anterior Cruciate Ligament Tear Using the Anatomic Single-Bundle Technique: A Clinical and Functional Outcome Evaluation. Cureus 2024; 16:e69069. [PMID: 39391455 PMCID: PMC11465764 DOI: 10.7759/cureus.69069] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/10/2024] [Indexed: 10/12/2024] Open
Abstract
BACKGROUND The anterior cruciate ligament (ACL) consists of an anteromedial bundle and a posterolateral bundle giving anteroposterior and rotational stability to the knee. An ACL tear might lead to secondary changes in the knee joint if not operated in time. The aim of the study was to evaluate the clinical and functional results in patients with ACL tears treated by arthroscopic reconstruction using the anatomic single-bundle technique. METHODS This was a prospective study conducted between June 2015 and December2017 at a teaching institute in Kolkata, India, on patients who underwent single-bundle arthroscopic reconstruction of an ACL tear. A minimum follow-up of nine months was considered for all patients. The functional outcome was assessed via the Lysholm knee score. RESULTS A total of 45 patients were included in this study, of which 34 (75.56%) and eight (17.78%) patients showed excellent and good results, respectively, at the final follow-up. The mean age in this study was 29.88±9.02 years. No complication was seen in 95.6% of patients. The mean Lysholm score by the end of nine months was 95.31±6.55. At the time of the final follow-up, all the patients returned to their same activity status prior to injury. CONCLUSION Arthroscopic anatomic single-bundle ACL reconstruction using hamstring autograft is an effective treatment modality for ACL injuries. It restores the stability of the knee and is associated with good recovery of joint function with an early return to active lifestyle and sports activities. This procedure achieves excellent clinical and functional outcomes without any long-term disability.
Collapse
Affiliation(s)
- Mahak Baid
- Orthopaedics, Aneurin Bevan University Health Board, Newport, GBR
| | - Shamik Hait
- Orthopaedics, Baksi Orthopaedics Trauma and Rehabilitation Centre, Kolkata, IND
| | - Saurabh Daga
- Orthopaedics, University Hospitals Birmingham NHS Foundation Trust, Birmingham, GBR
| | - Ayon Das
- Orthopaedics, Employees State Insurance Post Graduate Institute of Medical Sciences and Research (ESI-PGIMSR) Employees State Insurance Corporation (ESIC) Medical College and Hospital, Kolkata, IND
| | | | - Jerry Sam
- Orthopaedics, Aneurin Bevan University Health Board, Newport, GBR
| | | | - Ali Amjad
- Orthopaedics, Aneurin Bevan University Health Board, Newport, GBR
| | - Prashanth D'sa
- Orthopaedics, Aneurin Bevan University Health Board, Newport, GBR
| |
Collapse
|
2
|
Eggeling L, Drenck TC, Breer S, Frosch KH, Akoto R. Association of Remaining Anterior Knee Laxity With Inferior Outcomes After Revision ACL Reconstruction. Orthop J Sports Med 2024; 12:23259671231219695. [PMID: 38371998 PMCID: PMC10870811 DOI: 10.1177/23259671231219695] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/14/2023] [Accepted: 07/21/2023] [Indexed: 02/20/2024] Open
Abstract
Background The relationship between remaining anterior knee laxity and poorer clinical outcomes after anterior cruciate ligament reconstruction (ACLR) may be underrated, and the criteria for failure of revision ACLR have not been defined. Purpose/Hypothesis To evaluate a possible association between remaining knee laxity and functional scores in patients after revision ACLR. We hypothesized that a postoperative side-to-side-difference (SSD) in knee laxity of ≥6 mm will be an objective parameter for failure. Study Design Cohort study; Level of evidence, 3. Methods A total of 200 patients (77 women and 123 men; mean age, 30.8 ± 11 years; range, 18-61 years) who underwent revision ACLR between 2016 and 2019 were evaluated; The mean follow-up period was 30.2 ± 9 months (range, 24-67 months). Patients were divided into 3 groups according to postoperative SSD (<3 mm, 3-5 mm, or ≥6 mm). Preoperative and postoperative outcome measures (Lachman, pivot shift, visual analog scale [VAS] for pain, Tegner, Lysholm, International Knee Documentation Committee, and Knee injury and Osteoarthritis Outcome Score) were compared between the groups. Results Of the 200 patients, 74% (n = 148) had a postoperative SSD of <3 mm at the latest follow-up, 19.5% (n = 39) had a postoperative SSD of 3 to 5 mm, and 6.5% (n = 13) had a postoperative SSD of ≥6 mm. Patients in all groups saw significant pre- to postoperative reductions in positive Lachman and pivot-shift tests as well as significant improvements in VAS pain, Lysholm, and Tegner scores (P < .001 for all). All postoperative functional scores of the patients with SSDs of <3 mm and 3-5 mm were significantly increased compared with those of patients with an SSD of ≥6 mm (P≤ .01 for all). Conclusion In patients following revision ACLR, anterior and rotational knee laxity were successfully reduced while increasing postoperative functional outcomes. A remaining postoperative SSD of ≥6 mm was associated with inferior patient outcomes compared with an SSD <6 mm. An SSD of ≥6 mm represents an objective parameter in the definition of failure of revision ACLR.
Collapse
Affiliation(s)
- Lena Eggeling
- Department of Trauma Surgery, Orthopaedics and Sports Traumatology, BG Klinikum Hamburg, Hamburg, Germany
- Asklepios St. Georg Clinic, Hamburg, Germany
| | - Tobias Claus Drenck
- Department of Trauma Surgery, Orthopaedics and Sports Traumatology, BG Klinikum Hamburg, Hamburg, Germany
| | - Stephan Breer
- Department of Trauma Surgery, Orthopaedics and Sports Traumatology, BG Klinikum Hamburg, Hamburg, Germany
| | - Karl-Heinz Frosch
- Department of Trauma Surgery, Orthopaedics and Sports Traumatology, BG Klinikum Hamburg, Hamburg, Germany
- Department of Trauma Surgery and Orthopedics, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Ralph Akoto
- Department of Trauma Surgery, Orthopaedics and Sports Traumatology, BG Klinikum Hamburg, Hamburg, Germany
- Asklepios St. Georg Clinic, Hamburg, Germany
- Cologne Merheim Medical Center, University of Witten/Herdecke, Cologne, Germany
| |
Collapse
|
3
|
Liukkonen R, Vaajala M, Mattila VM, Reito A. Prevalence of post-traumatic osteoarthritis after anterior cruciate ligament injury remains high despite advances in surgical techniques. Bone Joint J 2023; 105-B:1140-1148. [PMID: 37907079 DOI: 10.1302/0301-620x.105b11.bjj-2023-0058.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/02/2023]
Abstract
Aims The aim of this study was to report the pooled prevalence of post-traumatic osteoarthritis (PTOA) and examine whether the risk of developing PTOA after anterior cruciate ligament (ACL) injury has decreased in recent decades. Methods The PubMed and Web of Science databases were searched from 1 January 1980 to 11 May 2022. Patient series, observational studies, and clinical trials having reported the prevalence of radiologically confirmed PTOA after ACL injury, with at least a ten-year follow-up, were included. All studies were analyzed simultaneously, and separate analyses of the operative and nonoperative knees were performed. The prevalence of PTOA was calculated separately for each study, and pooled prevalence was reported with 95% confidence intervals (CIs) using either a fixed or random effects model. To examine the effect of the year of injury on the prevalence, a logit transformed meta-regression analysis was used with a maximum-likelihood estimator. Results from meta-regression analyses were reported with the unstandardized coefficient (β). Results The pooled prevalence of PTOA was 37.9% (95% CI 32.1 to 44) for operatively treated ACL injuries with a median follow-up of 14.6 years (interquartile range (IQR) 10.6 to 16.7). For nonoperatively treated ACL injuries, the prevalence was 40.5% (95% CI 28.9 to 53.3), with a median of follow-up of 15 years (IQR 11.7 to 20.0). The association between the year of operation and the prevalence of PTOA was weak and imprecise and not related to the choice of treatment (operative β -0.038 (95% CI -0.076 to 0.000) and nonoperative β -0.011 (95% CI -0.101 to 0.079)). Conclusion The initial injury, irrespective of management, has, by the balance of probability, resulted in PTOA within 20 years. In addition, the prevalence of PTOA has only slightly decreased during past decades. Therefore, further research is warranted to develop strategies to prevent the development of PTOA after ACL injuries.
Collapse
Affiliation(s)
- Rasmus Liukkonen
- Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland
| | - Matias Vaajala
- Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland
| | - Ville M Mattila
- Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland
| | - Aleksi Reito
- Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland
| |
Collapse
|
4
|
Güzel N, Genç AS, Yılmaz AK, Kehribar L. The Relationship between Lower Extremity Functional Performance and Balance after Anterior Cruciate Ligament Reconstruction: Results of Patients Treated with the Modified All-Inside Technique. J Pers Med 2023; 13:466. [PMID: 36983648 PMCID: PMC10052949 DOI: 10.3390/jpm13030466] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Revised: 02/27/2023] [Accepted: 02/27/2023] [Indexed: 03/06/2023] Open
Abstract
BACKGROUND AND OBJECTIVES Anterior cruciate ligament (ACL) ruptures are common injuries, and ACL reconstruction (ACLR) is among the most common surgical procedures in sports surgery. Our research aims to compare the 6-month post-operative results of the modified all-inside (MAI) ACLR technique, single leg hop tests (SLHT), and Y balance tests applied in different directions on the operated and non-operated sides. MATERIALS AND METHODS A retrospective cohort of 22 male recreational athletes who underwent MAI ACLR techniques performed by the same surgeon were evaluated. The functional knee strengths of the participants on the operated and non-operated sides were evaluated with five different tests of SLHTs: single hop for distance (SH), triple hop for distance (TH), crossover triple hop for distance (CH), medial side triple hop for distance (MSTH), and medial rotation (90°) with hop for distance (MRH). Their dynamic balance was evaluated with the Y balance Test. RESULTS Compared to pre-operative levels, there was a significant improvement in the mean Lysholm, Tegner, and IKDC scores during the post-operative period (p < 0.05). There was a difference between SH, THD, CHD, MSTH, and MRH on the operated and non-operative sides (p < 0.05). There was no difference between Y balance scores on the operated and non-operative sides, and there were no differences between LSI scores resulting from SLHTs (p > 0.05). There were no significant relationships between YBT (composite scores) and SH, TH, CH, MSTH, and MRH distances in the healthy leg (p > 0.05), but a significant correlation with only CH in the ACL leg (p < 0.05). CONCLUSIONS Our research shows that sixth-month post-operative SLHT findings were lower on the ACL side compared to the healthy side in patients tested with the MAI ACLR technique. However, when these scores are evaluated in terms of balance, it can be seen that both sides reveal similar findings. The similarity of LSIs in SLHTs applied in different directions, and balance scores of ACL and healthy sides revealed that the MAI technique is also an ACLR technique that can be used in athletes from a functional point of view.
Collapse
Affiliation(s)
- Nizamettin Güzel
- Department of Orthopedics and Traumatology, Samsun Training and Research Hospital, 55090 Samsun, Türkiye
| | - Ahmet Serhat Genç
- Department of Orthopedics and Traumatology, Samsun Training and Research Hospital, 55090 Samsun, Türkiye
| | - Ali Kerim Yılmaz
- Departments of Recreation, Faculty of Yaşar Doğu Sport Sciences, Ondokuz Mayıs University, 55100 Samsun, Türkiye
| | - Lokman Kehribar
- Department of Orthopedics and Traumatology, Samsun University, 55090 Samsun, Türkiye
| |
Collapse
|
5
|
Posterior hamstring harvest improves aesthetic satisfaction and decreases sensory complications as compared to the classic anterior approach in anterior cruciate ligament reconstruction surgery. J Exp Orthop 2022; 9:109. [PMID: 36326935 PMCID: PMC9633883 DOI: 10.1186/s40634-022-00547-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/31/2022] [Accepted: 10/24/2022] [Indexed: 11/06/2022] Open
Abstract
Purpose The use of the posterior approach for harvesting hamstring grafts has recently become popular thanks to new all-inside techniques and retrograde drills. This study aims to compare the classic anterior approach with the posterior approach in the popliteal fossa. Methods Retrospective comparative study of 100 consecutive cases of primary ligamentoplasty performed using ipsilateral semitendinosus autograft with at least one year of follow-up. 50 patients with anterior approach (group A) and 50 patients with posterior approach (P). Ratio men/women: 9/1. Mean age: 32 ± 13 years. Mean operative time: 64.88 ± 12.28 min. Study variables Graft harvest time; intraoperative complications (semitendinous [ST] tendon cut); postoperative neurological complications (allodynia, paresthesia, pain) or hematoma in the donor area; atrophy of the operated thigh compared to the contralateral thigh, postoperative VAS score, aesthetic satisfaction and overall satisfaction. Results Graft harvest time of 9.5 min in group A versus 5.25 min in group P (p < 0.05). Sensory complications: 16% in group A versus 2% in group P (p < 0.05). Regarding the patient’s evaluation of the aesthetic result of the surgery, 80% in group A and 92% in group P were very satisfied, 16% in group A and 8% in group P were satisfied and 4% in group A and no patients in group P not very satisfied (p < 0.05). No significant differences were found in terms of total operative time, postoperative joint movement, atrophy of the operated thigh, postoperative VAS, or overall patient satisfaction. Conclusions The posterior approach to harvesting the ipsilateral hamstring graft obtained better results than the anterior approach in terms of aesthetic satisfaction of the patient, lower rate of neurological complications (allodynia, paresthesias and hypoesthesia in the anterior region of the knee and leg) and shorter hamstring harvest time. Level of evidence IV.
Collapse
|
6
|
Marshall DC, Silva FD, Goldenberg BT, Quintero D, Baraga MG, Jose J. Imaging Findings of Complications After Lateral Extra-Articular Tenodesis of the Knee: A Current Concepts Review. Orthop J Sports Med 2022; 10:23259671221114820. [PMID: 36062159 PMCID: PMC9434692 DOI: 10.1177/23259671221114820] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/11/2022] [Accepted: 05/11/2022] [Indexed: 11/16/2022] Open
Abstract
Background Despite successful anterior cruciate ligament (ACL) reconstruction, many patients continue to experience persistent anterolateral rotatory instability. Lateral extra-articular tenodesis (LET) is used to address this instability by harvesting a portion of the iliotibial band, passing it underneath the fibular collateral ligament, and attaching it just proximal and posterior to the lateral femoral epicondyle. Based on the most recent clinical evidence, the addition of LET to ACL reconstruction improves clinical outcomes, which has led to an increase in the use of this technique. Purpose To provide an overview of the postoperative complications of the LET procedure and their associated imaging findings, with a focus on magnetic resonance imaging (MRI). Study Design Narrative review. Methods In this scoping review, the authors reviewed available radiographic, computed tomography, and MRI scans of patients who experienced postoperative complications after ACL reconstruction with LET, in which the complication was determined to be from the LET procedure. Images were reviewed and subsequently described by an on-staff musculoskeletal radiologist. Results The authors found 9 different complications associated with LET: graft failure, hematoma, infection, chronic pain, tunnel convergence, fixation device migration, muscular hernia, peroneal nerve palsy, and knee stiffness. They supplemented these findings with radiographic evidence from 6 patients. Conclusion As extra-articular reconstruction techniques including LET become more popular among orthopaedic surgeons, it is important that radiologists and surgeons be adept at recognizing the normal imaging findings of LET and associated complications.
Collapse
Affiliation(s)
- Danielle C. Marshall
- Department of Orthopaedics, University of Miami/Jackson Memorial
Hospital, Miami, Florida, USA
| | - Flavio D. Silva
- Department of Radiology, Grupo Osteomuscular, Fleury Medicine e
Saúde, São Paulo, Brazil
| | - Brandon T. Goldenberg
- Department of Orthopaedics, University of Miami/Jackson Memorial
Hospital, Miami, Florida, USA
| | - Daniel Quintero
- Department of Orthopaedics, University of Miami/Jackson Memorial
Hospital, Miami, Florida, USA
- Department of Radiology, University of Miami/Jackson Memorial
Hospital, Miami, Florida, USA
| | - Michael G. Baraga
- Department of Orthopaedics, University of Miami/Jackson Memorial
Hospital, Miami, Florida, USA
| | - Jean Jose
- Department of Radiology, University of Miami/Jackson Memorial
Hospital, Miami, Florida, USA
| |
Collapse
|
7
|
Young men are at higher risk of failure after ACL hamstring reconstructions: a retrospective multivariate analysis. BMC Musculoskelet Disord 2022; 23:598. [PMID: 35729572 PMCID: PMC9210756 DOI: 10.1186/s12891-022-05547-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/02/2021] [Accepted: 06/06/2022] [Indexed: 11/16/2022] Open
Abstract
Background Results of ACL reconstruction are influenced by both patient and surgical variables. Until now a significant amount of studies have focused on the influence of surgical technique on primary outcome, often leaving patient variables untouched. This study investigates the combined influence of patient and surgical variables through multivariate analysis. Methods Single-center retrospective cohort study. All patients who underwent primary ACL hamstring reconstruction within a 5-year period were included. Patient characteristics (gender, age, height, weight, BMI at time of surgery) and surgical variables (surgical technique, concomitant knee injury, graft diameter, type of femoral and tibial fixation) were collected. Patients were asked about Tegner Activity Scale (TAS), complications and revision surgery. Multivariate logistic regression was used to study risk factors. First graft failure and potential risk factors (patient and surgical) were univariately assessed. Risk factors with a p-value ≤ 0.05 were included in the multivariate model. Results Six hundred forty-seven primary ACL hamstring reconstructions were included. There were 41 graft failures (failure rate 6.3%). Patient gender, age, height and preoperative TAS had a significant influence on the risk of failure in the univariate analysis. The multivariate analyses showed that age and sex remained significant independent risk factors. Patients with a failed ACL reconstruction were younger (24.3 vs 29.4 years, OR 0.937), with women at a lower risk for failure of their ACL reconstruction (90.2% males vs 9.8% females, female OR 0.123). ACL graft diameter and other surgical variables aren’t confounders for graft failure. Conclusion This study shows that patient variables seem to have a larger influence on the failure rate of ACL hamstring reconstructive surgery than surgical variables. Identification of the right patient variables can help us make more informed decisions for our patients and create patient-specific treatment protocols. Young men’s higher risk of failure suggests that these patients may benefit from a different reconstruction technique, such as use of a patellar tendon or combined ligament augmentation. Level of evidence Retrospective cohort III. Supplementary Information The online version contains supplementary material available at 10.1186/s12891-022-05547-8.
Collapse
|
8
|
Kehribar L, Yılmaz AK, Karaduman E, Kabadayı M, Bostancı Ö, Sürücü S, Aydın M, Mahiroğulları M. Post-Operative Results of ACL Reconstruction Techniques on Single-Leg Hop Tests in Athletes: Hamstring Autograft vs. Hamstring Grafts Fixed Using Adjustable Cortical Suspension in Both the Femur and Tibia. MEDICINA (KAUNAS, LITHUANIA) 2022; 58:medicina58030435. [PMID: 35334611 PMCID: PMC8950666 DOI: 10.3390/medicina58030435] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/14/2022] [Revised: 03/11/2022] [Accepted: 03/14/2022] [Indexed: 01/13/2023]
Abstract
Background and Objectives: Anterior cruciate ligament (ACL) tears are common injuries in the athletic population, and accordingly, ACL reconstruction (ACLR) is among the most common orthopedic surgical procedures performed in sports medicine. This study aims to compare the semitendinosus/gracilis (ST/G) and ACL hamstring grafts fixed using adjustable cortical suspension in both the femur and tibia (MAI) ACLR techniques. We aimed to compare the results of single-leg hop tests (SLHT) applied in different directions and limb symmetry indices (LSI) in athletes with a 6-month post-operative ACLR history. Materials and Methods: A retrospective cohort of 39 athletes from various sports branches who underwent MAI (n = 16) and ST/G (n = 23) ACLR techniques by the same surgeon were evaluated. The knee strength of the participants on the operated and non-operated sides was evaluated with five different SLHTs. The SLHT included the single hop for distance (SH), triple hop for distance (TH), crossover triple hop for distance (CH), medial side triple hop for distance (MSTH), and medial rotation (90°) hop for distance (MRH). Results: There was a significant improvement in the mean Lysholm, Tegner, and IKDC scores in the post-operative leg for both techniques (p < 0.05) compared to the pre-operative levels. When there was a difference between the SH of the operative and the non-operative legs in the ST/G technique (p < 0.05), there was no significant difference in the other hop distance for both ST/G and MAI (p > 0.05). There was no difference between the techniques regarding the LSI scores. Conclusions: The fact that our research revealed similar LSI rates of the SLHTs applied in different directions in the ST/G and MAI techniques assumes that the MAI technique can be an ACLR technique which can be functionally used in athletes.
Collapse
Affiliation(s)
- Lokman Kehribar
- Department of Orthopaedics and Traumatology, Samsun University, Samsun 55090, Turkey;
| | - Ali Kerim Yılmaz
- Faculty of Yaşar Doğu Sport Sciences, Ondokuz Mayıs University, Samsun 55270, Turkey; (E.K.); (M.K.); (Ö.B.)
- Correspondence: or ; Tel.: +90-542-495-3737
| | - Emre Karaduman
- Faculty of Yaşar Doğu Sport Sciences, Ondokuz Mayıs University, Samsun 55270, Turkey; (E.K.); (M.K.); (Ö.B.)
| | - Menderes Kabadayı
- Faculty of Yaşar Doğu Sport Sciences, Ondokuz Mayıs University, Samsun 55270, Turkey; (E.K.); (M.K.); (Ö.B.)
| | - Özgür Bostancı
- Faculty of Yaşar Doğu Sport Sciences, Ondokuz Mayıs University, Samsun 55270, Turkey; (E.K.); (M.K.); (Ö.B.)
| | - Serkan Sürücü
- Department of Orthopaedics, University of Missouri, Kansas City, MO 64108, USA;
| | - Mahmud Aydın
- Haseki Training and Research Hospital, Orthopaedics and Traumatology, Istanbul 34096, Turkey;
| | - Mahir Mahiroğulları
- Memorial Sisli Hospital, Orthopaedics and Traumatology, Istanbul 34384, Turkey;
| |
Collapse
|
9
|
Viglietta E, Ponzo A, Monaco E, Iorio R, Drogo P, Andreozzi V, Conteduca F, Ferretti A. ACL Reconstruction Combined With the Arnold-Coker Modification of the MacIntosh Lateral Extra-articular Tenodesis: Long-term Clinical and Radiological Outcomes. Am J Sports Med 2022; 50:404-414. [PMID: 34939890 DOI: 10.1177/03635465211062609] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Interest in the role of lateral extra-articular tenodesis (LET) in preventing rotatory instability and the pivot-shift phenomenon after anterior cruciate ligament reconstruction (ACLR) has been recently renewed. Nevertheless, there is still concern about overconstraint of the lateral compartment of the knee and the risk of subsequent osteoarthritis (OA). PURPOSE The purpose of this retrospective study was to compare long-term subjective and objective outcomes and the rate of OA development between patients undergoing isolated ACLR (iACLR) with a hamstring tendon autograft and those with a combined Arnold-Coker modification of the McIntosh extra-articular procedure. Risk factors for long-term OA were evaluated. STUDY DESIGN Cohort study; Level of evidence, 3. METHODS The study included 165 consecutive patients treated at a single center by ACLR. A total of 86 patients underwent iACLR (iACLR group) and 79 received combined intra- and extra-articular reconstruction (ACLR+LET). The International Knee Documentation Committee (IKDC), Lysholm, and Tegner activity scores were administered. Knee stability was tested through the Lachman test, the pivot-shift test, and the KT-1000 knee arthrometer test. A positive pivot-shift test (++/+++), laxity on the KT-1000, and referred giving-way episodes or revision ACLR were considered failures. Radiographic results were assessed according to the Fairbank, IKDC, and Kellgren-Lawrence scales. Radiographic evaluation included both the overall tibiofemoral joint and the medial and lateral compartment separately. A univariate and a multivariate logistic regression with penalized maximum likelihood was used to identify risks factors associated with long-term OA. RESULTS The mean follow-up was 15.7 years. There were no statistically significant differences in subjective scores between the 2 groups. A side-to-side difference >5 mm on the KT-1000 arthrometer evaluation was found in 8 patients in the iACLR group and in 1 patient in the ACLR+LET group (P = .01). Nine cases of failure were found in the iACLR group and only 1 case was found in the ACLR+LET group (P = .0093). Patients in the iACLR group had a significantly higher OA grades than those in the ACLR+LET group for the overall tibiofemoral joint and the lateral compartment of the knee. No differences were found in the medial compartment. A higher level of lateral compartment OA was found in patients who received partial lateral meniscectomy in the iACLR group compared with those in the ACLR+LET group. Univariate and multivariate analysis results demonstrated that meniscectomy was the most significant factor for long-term OA development. CONCLUSION A significantly higher risk of long-term OA was found with iACLR than with ACLR combined with the Arnold-Coker modification of the McIntosh extra-articular procedure. Knees with combined ACLR also had a significantly lower OA grade after partial lateral meniscectomy. Additionally, those undergoing combined ACLR had better knee stability and lower graft rupture rates at the long-term follow-up. Partial meniscectomy was the main risk factor negatively associated with OA changes.
Collapse
Affiliation(s)
- Edoardo Viglietta
- Orthopaedic & Traumatology Unit of Sant'Andrea Hospital, Sapienza University of Rome, Rome, Italy
| | - Antonio Ponzo
- Orthopaedic & Traumatology Unit of Sant'Andrea Hospital, Sapienza University of Rome, Rome, Italy
| | - Edoardo Monaco
- Orthopaedic & Traumatology Unit of Sant'Andrea Hospital, Sapienza University of Rome, Rome, Italy
| | - Raffaele Iorio
- Orthopaedic & Traumatology Unit of Sant'Andrea Hospital, Sapienza University of Rome, Rome, Italy
| | - Piergiorgio Drogo
- Orthopaedic & Traumatology Unit of Sant'Andrea Hospital, Sapienza University of Rome, Rome, Italy
| | - Valerio Andreozzi
- Orthopaedic & Traumatology Unit of Sant'Andrea Hospital, Sapienza University of Rome, Rome, Italy
| | - Fabio Conteduca
- Orthopaedic & Traumatology Unit of Sant'Andrea Hospital, Sapienza University of Rome, Rome, Italy
| | - Andrea Ferretti
- Orthopaedic & Traumatology Unit of Sant'Andrea Hospital, Sapienza University of Rome, Rome, Italy
| |
Collapse
|
10
|
Marchiori G, Lopomo NF, Bologna E, Spadaro D, Camarda L, Berni M, Visani A, Zito M, Zaffagnini S, Zingales M. How preconditioning and pretensioning of grafts used in ACLigaments surgical reconstruction are influenced by their mechanical time-dependent characteristics: Can we optimize their initial loading state? Clin Biomech (Bristol, Avon) 2021; 83:105294. [PMID: 33667940 DOI: 10.1016/j.clinbiomech.2021.105294] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/07/2020] [Revised: 02/08/2021] [Accepted: 02/12/2021] [Indexed: 02/07/2023]
Abstract
PURPOSE Consensus about a pre-implant preparation protocol adaptable to any graft used in Anterior Cruciate Ligament reconstruction is still lacking. In fact, there is not agreement on reliable metrics that consider both specific graft dimensional characteristics, such as its diameter, and the inherent properties of its constitutive material, i.e. ligaments or tendons. Aim of the present study was to investigate and propose the applied engineering stress as a possible metrics. METHODS Preconditioning and pretensioning protocol involved groups of grafts with different section (10 or 32 mm2) and materials (i.e. human patellar and hamstring tendons, and synthetic grafts). A 140 N load was applied to the grafts and maintained for 100 s. Initial stress and following stress-relaxation (a mechanical characteristic that can be related to knee laxity) were specifically analysed. FINDINGS Initial stress, ranging between 4 and 12 MPa, was affected primarily by the graft cross-section area and secondarily by the choice of the graft material. In terms of loss of the initial stress, stress-relaxation behaviour varied instead on a narrower range, namely 13-17%. INTERPRETATION Engineering stress can be identified as the correct metrics to optimize the initial state of each graft to avoid excessive stiffness, laxity or fatigue rupture phenomena.
Collapse
Affiliation(s)
- Gregorio Marchiori
- IRCCS Istituto Ortopedico Rizzoli, Laboratorio di Scienze e Tecnologie Chirurgiche, Via di Barbiano 1/10, 40136 Bologna, Italy
| | - Nicola Francesco Lopomo
- IRCCS Istituto Ortopedico Rizzoli, Laboratorio di Scienze e Tecnologie Chirurgiche, Via di Barbiano 1/10, 40136 Bologna, Italy; Department of Information Engineering, University of Brescia, Via Branze 38, 25123, Brescia, Italy
| | - Emanuela Bologna
- Engineering Department, University of Palermo, Viale delle Scienze ed.8, 90100 Palermo, Italy; Bio/NanoMechanics for Medical Sciences Laboratory, ATeN-Center, University of Palermo, Viale delle Scienze ed.8, 90100 Palermo, Italy
| | - Doriana Spadaro
- Fallprotec SA, 43-45 ZA Op Zaemer, 4959 Bascharage, Luxembourg
| | - Lawrence Camarda
- Department of Discipline Surgical, Oncology and Dentistry, University of Palermo, Via Liborio Giuffrè, 5, 90127, Palermo, Italy
| | - Matteo Berni
- IRCCS Istituto Ortopedico Rizzoli, Laboratorio di Tecnologia Medica, Via di Barbiano 1/10, 40136 Bologna, Italy
| | - Andrea Visani
- IRCCS Istituto Ortopedico Rizzoli, Laboratorio di Scienze e Tecnologie Chirurgiche, Via di Barbiano 1/10, 40136 Bologna, Italy
| | - Marianna Zito
- Engineering Department, University of Palermo, Viale delle Scienze ed.8, 90100 Palermo, Italy
| | - Stefano Zaffagnini
- IRCCS Istituto Ortopedico Rizzoli, IIa Clinica Ortopedica e Traumatologica, Via Pupilli 1/10, 40136 Bologna, Italy
| | - Massimiliano Zingales
- Engineering Department, University of Palermo, Viale delle Scienze ed.8, 90100 Palermo, Italy; Bio/NanoMechanics for Medical Sciences Laboratory, ATeN-Center, University of Palermo, Viale delle Scienze ed.8, 90100 Palermo, Italy.
| |
Collapse
|
11
|
Su M, Jia X, Zhang Z, Jin Z, Li Y, Dong Q, Xu W. Medium-Term (Least 5 Years) Comparative Outcomes in Anterior Cruciate Ligament Reconstruction Using 4SHG, Allograft, and LARS Ligament. Clin J Sport Med 2021; 31:e101-e110. [PMID: 30855342 PMCID: PMC7928216 DOI: 10.1097/jsm.0000000000000730] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/23/2018] [Accepted: 12/21/2018] [Indexed: 02/02/2023]
Abstract
OBJECTIVE To compare the clinical efficacy of anterior cruciate ligament (ACL) reconstruction with 4-strand hamstring tendon autograft (4SHG), allograft and the Ligament Advanced Reinforcement System (LARS) ligament, and to find the causes of cumulative failure or nonreturn to sport. DESIGN Retrospective case series. SETTING Department of Orthopedic Surgery, the second affiliated hospital of Soochow University, Suzhou, Jiangsu, China. PATIENTS Three hundred six patients with isolated ACL deficiency were included. Two hundred twenty-nine patients met the inclusion/exclusion criteria, and finally, 185 of these patients participated in this study. INTERVENTIONS Anterior cruciate ligament reconstruction using 4SHG, allograft, and LARS. MAIN OUTCOME MEASURES Objective knee function, subjective knee function, and information regarding return to sport, cumulative failure, and complications. Secondary: distribution of tunnel position and tunnel enlargement. RESULTS There were no statistically significant differences between the 3 groups regarding all the clinical objective and subjective results, return to sport, complications, or cumulative failures (P > 0.05). One hundred twenty-eight patients (69.2%, 128/185) returned to sport. Preoperative (after injury) Tegner scores were inferior to postoperative Tegner scores, and postoperative Tegner scores were inferior to preinjury Tegner scores (P < 0.01). The femoral tunnel malposition was significantly associated with cumulative failure (P < 0.05). CONCLUSIONS There were no statistically significant differences among the 4SHG, allograft, and LARS ligament in terms of the clinical outcomes after ACL reconstruction (ACLR) at 5-years follow-up. Interestingly, ACLR could improve the functional and motorial level of the knee, but patients had great difficulty in regaining the level of preinjury movement. In addition, the malposition of the femoral tunnel was an important cause of cumulative failure.
Collapse
Affiliation(s)
- Mengdi Su
- Second Affiliated Hospital of Soochow University, Suzhou, Jiangsu, China
- School of Medicine, Soochow University, Suzhou, Jiangsu, China; and
| | - Xinyu Jia
- Second Affiliated Hospital of Soochow University, Suzhou, Jiangsu, China
- School of Medicine, Soochow University, Suzhou, Jiangsu, China; and
| | - Zaihang Zhang
- Second Affiliated Hospital of Soochow University, Suzhou, Jiangsu, China
- School of Medicine, Soochow University, Suzhou, Jiangsu, China; and
| | - Zhigao Jin
- Second Affiliated Hospital of Soochow University, Suzhou, Jiangsu, China
- School of Medicine, Soochow University, Suzhou, Jiangsu, China; and
| | - Yong Li
- Second Affiliated Hospital of Soochow University, Suzhou, Jiangsu, China
- School of Medicine, Soochow University, Suzhou, Jiangsu, China; and
| | - Qirong Dong
- Second Affiliated Hospital of Soochow University, Suzhou, Jiangsu, China
- School of Medicine, Soochow University, Suzhou, Jiangsu, China; and
| | - Wei Xu
- Second Affiliated Hospital of Soochow University, Suzhou, Jiangsu, China
- School of Medicine, Soochow University, Suzhou, Jiangsu, China; and
| |
Collapse
|
12
|
Viscoelastic and failure properties of two configurations of triple-folded hamstring tendons used for anterior cruciate ligament (ACL) reconstruction. Knee 2021; 29:174-182. [PMID: 33639560 DOI: 10.1016/j.knee.2021.01.029] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/01/2020] [Revised: 01/23/2021] [Accepted: 01/26/2021] [Indexed: 02/02/2023]
Abstract
BACKGROUND Hamstring autografts are commonly used for anterior cruciate ligament (ACL) reconstruction. Different folding techniques exist in tripling the semitendinosus. Few anatomical studies exist in evaluating their viscoelastic properties. The purpose of this study was to characterize and compare the viscoelastic and failure properties of two hamstring graft configurations, the "Z" construct and "2" construct. METHODS Ten matched pairs of fresh-frozen cadaveric semitendinosus hamstring grafts were used to create the "2" configuration or "Z" configuration. The biomechanical testing consisted of four phases: preconditioning, where graft dimensions (mm) were measured; stress relaxation, where load, displacement and time data were collected and equilibrium relaxation (%) was calculated; dynamic creep, where the total construct elongation was calculated; and ramp-to-failure, where maximum failure load was recorded. RESULTS The "2" configuration demonstrated recorded forces (N) significantly greater at each time point when compared to the "Z" configuration during stress relaxation (p = 0.003). The "2" configuration exhibited significantly less construct elongation (mm) during dynamic creep at 10 cycles (p = 0.008) and 2000 cycles (p = 0.0001). The maximum measured load at failure was significantly greater in the "2" configuration constructs than "Z" configuration (p = 0.013). Moreover, the axial loads at 2, 3 and 4 mm of displacement were, on average, greater in the "2" configuration than "Z" configuration (p = 0.152; p = 0.080; p = 0.012), respectively. CONCLUSION The results of this study provide support for folding techniques for tripled grafts to provide higher viscoelastic and failure properties for techniques with less suture interfaces. Future studies can potentially evaluate the clinical significance of these findings.
Collapse
|
13
|
Bangert Y, Jaber A, Wünnemann F, Berrsche G, Streich N, Rehnitz C, Ott H, Barié A. Clinical and radiological outcome after anterior cruciate ligament reconstruction using the T-lock Osteotrans resorbable tendon anchor: early experience and midterm follow-up. BMC Musculoskelet Disord 2020; 21:844. [PMID: 33339540 PMCID: PMC7749500 DOI: 10.1186/s12891-020-03863-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/28/2020] [Accepted: 12/04/2020] [Indexed: 01/14/2023] Open
Abstract
PURPOSE Reconstruction of the Anterior cruciate ligament (ACL) using tendon grafting is an established method for restoring knee function and stability. Multiple methods are established for graft fixation. Several involve anchoring the autograft distant to the joint with hardware that remains implanted. This study reports the first early to midterm results in patients who received ACL reconstruction (ACLR) using the T-Lock Osteotrans femoral near joint fixation method with a tibial fixation using the BioactIF Osteotrans interference screw. METHODS This consecutive prospective series included 20 Patients (14 Male, 6 Female) with a primary ACL rupture. All patients were treated with an ACLR using a semitendinosus autograft fixated with the T-Lock Osteotrans and were followed-up postoperatively. The following parameters were assessed: Side-to-side difference of the posterior-anterior translation measured using the KT-1000 arthrometer, Tegner activity score, Lysholm score, IKDC subjective knee evaluation form. Magnetic resonance imaging (MRI) was done to assess tunnel enlargement and integrity of the anchoring device. RESULTS The average follow-up duration was 2 years (range 1-4.2 years). One patient was lost to follow-up. Two Patients suffered a traumatic ACL re-rupture 2 years postoperatively and received a 2-stage revision ACLR. Difference in the posterior-anterior translation was 1.8 mm (range 0-5). The median Tegner score was 6 (range 4-10) and 9 patients (45%) returned to their preinjury level of activity. The mean IKDC subjective knee evaluation form scored 91 points (range 77-100). The mean Lysholm score was 86 points (74-96). All mentioned scores were significantly better compared to preoperative values. No relevant tunnel enlargement was seen on MRI. The anchoring device was evaluated to be intact in all patients. CONCLUSION ACLR with the aforementioned procedure leads to good clinical and radiological outcome.
Collapse
Affiliation(s)
- Y Bangert
- Department of Orthopaedic and Trauma Surgery, Center for Orthopaedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Schlierbacher Landstrasse 200a, 69118, Heidelberg, Germany.
| | - A Jaber
- Department of Orthopaedic and Trauma Surgery, Center for Orthopaedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Schlierbacher Landstrasse 200a, 69118, Heidelberg, Germany
| | - F Wünnemann
- Department of diagnostic and interventional radiology, Heidelberg University Hospital, Schlierbacher Landstrasse 200a, 69118, Heidelberg, Germany
| | - G Berrsche
- Department of Orthopaedic and Trauma Surgery, Center for Orthopaedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Schlierbacher Landstrasse 200a, 69118, Heidelberg, Germany
| | - N Streich
- Center for Joint Surgery and Sport injuries, Sportopaedie Heidelberg, Clinic St. Elisabeth Heidelberg, Max-Reger-Straße 5-7, 69121, Heidelberg, Germany
| | - C Rehnitz
- Department of diagnostic and interventional radiology, Heidelberg University Hospital, Schlierbacher Landstrasse 200a, 69118, Heidelberg, Germany
| | - H Ott
- Sporthologicum - Center for Sport and Joint injuries, Siesmayerstraße 44, 60323, Frankfurt am Main, Germany
| | - A Barié
- Department of Orthopaedic and Trauma Surgery, Center for Orthopaedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Schlierbacher Landstrasse 200a, 69118, Heidelberg, Germany.,Center for Joint Surgery and Sport injuries, Sportopaedie Heidelberg, Clinic St. Elisabeth Heidelberg, Max-Reger-Straße 5-7, 69121, Heidelberg, Germany
| |
Collapse
|
14
|
Cavaignac E, Mesnier T, Marot V, Fernandez A, Faruch M, Berard E, Sonnery-Cottet B. Effect of Lateral Extra-articular Tenodesis on Anterior Cruciate Ligament Graft Incorporation. Orthop J Sports Med 2020; 8:2325967120960097. [PMID: 33299900 PMCID: PMC7711232 DOI: 10.1177/2325967120960097] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/09/2020] [Accepted: 07/30/2020] [Indexed: 12/28/2022] Open
Abstract
Background: It has been shown that adding lateral extra-articular tenodesis (LET) to
standard anterior cruciate ligament (ACL) reconstruction significantly
decreases the loads on the ACL composite graft. To date, the possible effect
of LET on ACL graft incorporation is not known. Purpose: To compare the incorporation in tibial bone tunnels of a standard quadrupled
semitendinosus (ST4) graft to an ST4 graft plus LET at 1 year
postoperatively using magnetic resonance imaging (MRI). Study Design: Cohort study; Level of evidence, 3. Methods: A total of 62 patients who underwent ACL reconstruction were enrolled
prospectively: 31 received an ST4 graft, and 31 received an ST4 graft plus
LET. Graft incorporation was evaluated with MRI at the 1-year follow-up
visit. The following parameters were evaluated: signal-to-noise quotient
(SNQ), tibial tunnel widening, graft healing, and graft maturity according
to the Howell scale. The primary endpoint was the SNQ of the ST4 graft at 1
year postoperatively; this parameter was adjusted because of unequal
baseline characteristics between groups. Clinical and functional outcomes as
well as incorporation of the graft were analyzed as secondary endpoints. Results: The mean adjusted SNQ was 0.5 ± 2.1 (95% CI, 0.4-4.6) in the ST4 + LET group
and 5.9 ± 3.7 (95% CI, 4.7-7.0) in the ST4 group (P =
.0297). The mean tibial tunnel widening was 73.7% ± 42.2% in the ST4 + LET
group versus 77.5% ± 46.7% in the ST4 group (P = .5685).
Howell grade I, indicative of better graft maturity, was statistically more
frequent in the ST4 + LET group (P = .0379). No
statistically significant difference was seen between groups in terms of
graft healing (P = .1663). The Lysholm score was
statistically higher in the ST4 + LET group (P = .0058). No
significant differences were found between groups in terms of the
International Knee Documentation Committee subjective score
(P = .2683) or Tegner score (P =
.7428). The mean SNQ of the LET graft at the 1-year follow-up visit was 2.6
± 4.9. Conclusion: At 1 year postoperatively, the MRI appearance of ACL grafts showed generally
better incorporation and maturation when combined with LET.
Collapse
Affiliation(s)
- Etienne Cavaignac
- Department of Orthopedic Surgery and Trauma, Hôpital Pierre-Paul Riquet, Centre Hospitalier Universitaire de Toulouse, Toulouse, France.,I2R, Institut de Recherche Riquet, Toulouse, France
| | - Timothée Mesnier
- Department of Orthopedic Surgery and Trauma, Hôpital Pierre-Paul Riquet, Centre Hospitalier Universitaire de Toulouse, Toulouse, France
| | - Vincent Marot
- Department of Orthopedic Surgery and Trauma, Hôpital Pierre-Paul Riquet, Centre Hospitalier Universitaire de Toulouse, Toulouse, France
| | - Andrea Fernandez
- Department of Orthopedic Surgery and Trauma, Hôpital Pierre-Paul Riquet, Centre Hospitalier Universitaire de Toulouse, Toulouse, France
| | - Marie Faruch
- Department of Radiology, Hôpital Pierre-Paul Riquet, Centre Hospitalier Universitaire de Toulouse, Toulouse, France
| | - Emilie Berard
- Department of Epidemiology, Health Economics and Public Health, Centre Hospitalier Universitaire de Toulouse, University of Toulouse III, Toulouse, France
| | | |
Collapse
|
15
|
Roger J, Bertani A, Vigouroux F, Mottier F, Gaillard R, Have L, Rongièras F. ACL reconstruction using a quadruple semitendinosus graft with cortical fixations gives suitable isokinetic and clinical outcomes after 2 years. Knee Surg Sports Traumatol Arthrosc 2020; 28:2468-2477. [PMID: 32699919 DOI: 10.1007/s00167-020-06121-2] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/13/2019] [Accepted: 06/24/2020] [Indexed: 12/17/2022]
Abstract
PURPOSE The objective of this single-center randomized single-blinded trial was to assess the hypothesis that anterior cruciate ligament reconstruction (ACLR) using a four-strand semitendinosus (ST) graft with adjustable femoral and tibial cortical fixation produced good outcomes compared to an ST/gracilis (ST/G) graft with femoral pin transfixation and tibial bioscrew fixation. Follow-up was 2 years. METHODS Patients older than 16 years who underwent primary isolated ACLR included for 1 year until August 2017 were eligible. The primary outcome measures were the subjective International Knee Documentation Committee (IKDC) score, isokinetic muscle strength recovery, and return to work within 2 years. The study was approved by the ethics committee. RESULTS Of 66 eligible patients, 60 completed the study and were included, 33 in the 4ST group and 27 in the ST/G group. Mean age was 30.5 ± 8.9 years in the 4ST group and 30.3 ± 8.5 in the ST/G group (n.s.). No significant between-group differences were found for mean postoperative subjective IKDC (4ST group, 80.2 ± 12.5; ST/G group, 83.6 ± 13.6; n.s.), side-to-side percentage deficits in isokinetic hamstring strength (at 60°/s: ST group, 17% ± 16%; ST/G group, 14% ± 11%; n.s.) or quadriceps strength (at 60°/s: ST group, 14% ± 12%; ST/G group, 19% ± 17%; n.s.), return to work, pain during physical activities, side-to-side differential laxity, balance, loss of flexion/extension, or surgical complications. CONCLUSION This trial demonstrates that functional outcomes after 4ST for ACLR with cortical fixations could be as good, although not better, than those obtained using ST/G. The 4ST technique spares the gracilis tendon, which thus preserves the medial sided muscle and thereby could improve function and limit donor-side morbidity. LEVEL OF EVIDENCE Level I.
Collapse
Affiliation(s)
- Julien Roger
- Division of Orthopaedic Surgery, Department of Surgery, Hôpital de La Croix Rousse, Hospices Civils de Lyon, 103 Grande Rue de la Croix Rousse, 69004, Lyon, France.
| | - Antoine Bertani
- Division of Orthopaedic Surgery, Department of Surgery, Hôpital Edouard Herriot, Hospices Civils de Lyon, Lyon, France.
| | - Florence Vigouroux
- Division of Orthopaedic Surgery, Department of Surgery, Hôpital d'Instruction des Armées Bégin, Service de Santé des Armées, Saint-Mandé, France
| | - Franck Mottier
- Division of Orthopaedic Surgery, Department of Surgery, Centre Hospitalier Pierre Oudot, Bourgoin-Jallieu, France
| | - Romain Gaillard
- Division of Orthopaedic Surgery, Department of Surgery, Hôpital de La Croix Rousse, Hospices Civils de Lyon, 103 Grande Rue de la Croix Rousse, 69004, Lyon, France
| | - Laurence Have
- Department of Physical and Medical Rehabilitation, Hôpital Edouard Herriot, Hospices Civils de Lyon, Lyon, France
| | - Frédéric Rongièras
- Division of Orthopaedic Surgery, Department of Surgery, Hôpital Edouard Herriot, Hospices Civils de Lyon, Lyon, France
| |
Collapse
|
16
|
Plaweski S, Lanternier H. Is quadruple semitendinosus tendon strands autograft a better choice than hamstring autograft for anterior cruciate ligament reconstruction? A comparative study with a mean follow-up of 3 years. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY 2020; 30:1473-1479. [PMID: 32617686 DOI: 10.1007/s00590-020-02729-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/18/2020] [Accepted: 06/25/2020] [Indexed: 10/23/2022]
Abstract
PURPOSE The purpose of this study was to compare the clinical outcomes of ST4 with those of STGs with a minimum follow-up of 3 years. The hypothesis was that functional outcomes of the ST4 technique are at least as good as those of the STG technique. STUDY DESIGN Cohort study. Level of evidence, 3 METHODS: Eighty-seven consecutive patients underwent isolated ACL reconstruction, 50 with the ST4 and 37 with STG. At the femoral side for both groups, the system of the fixation of the graft used a cortical fixation support and at the tibial side the group STG used an interference screw and the ST4 group used a tape locked system fixed by an interference screw. Clinical results were compared: IKDC score, KT-1000 arthrometry, radiologic evaluation of the differential laxity, as well as the Tegner score and the KOOS score. RESULTS Two patients had a rerupture (STG), one in the ST4 group. The analysis of the subjective clinical results showed no statistically significant difference between the 2 groups. Differential laximetry was 0.7 mm ± 0.4 (0 to 2 mm) for the ST4 group and 1.6 ± 0.5 mm (0 to 3 mm) for the STG group with a statistically significant difference in favor of the ST4 group (p < 0.05). Age, sex, and presence of meniscal lesions were the factors influencing the KOOS score. CONCLUSION This study comparing the clinical and laximetric results at the minimum 3-year follow-up of 2 ACL reconstruction techniques (ST4 vs STG) confirms the working hypothesis with an overall better score for the ST4 group.
Collapse
Affiliation(s)
- Stéphane Plaweski
- Clinique Universitaire de Chirurgie Orthopédique Et Traumatologie du Sport, Hôpital Sud CHU Grenoble, 38047, Grenoble, France.
| | | |
Collapse
|
17
|
Kuršumović K, Charalambous CP. Relationship of Graft Type and Vancomycin Presoaking to Rate of Infection in Anterior Cruciate Ligament Reconstruction. JBJS Rev 2020; 8:e1900156. [DOI: 10.2106/jbjs.rvw.19.00156] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
|
18
|
Rothrauff BB, Jorge A, de Sa D, Kay J, Fu FH, Musahl V. Anatomic ACL reconstruction reduces risk of post-traumatic osteoarthritis: a systematic review with minimum 10-year follow-up. Knee Surg Sports Traumatol Arthrosc 2020; 28:1072-1084. [PMID: 31471726 DOI: 10.1007/s00167-019-05665-2] [Citation(s) in RCA: 57] [Impact Index Per Article: 14.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/14/2019] [Accepted: 08/05/2019] [Indexed: 12/13/2022]
Abstract
PURPOSE To systematically review the literature for radiographic prevalence of osteoarthritis (OA) at a minimum of 10 years following anterior cruciate ligament (ACL) reconstruction (ACLR) with anatomic vs. non-anatomic techniques. It was hypothesized that the incidence of OA at long-term follow-up would be lower following anatomic compared to non-anatomic ACLR. METHODS A systematic review was performed by searching PubMed, MEDLINE, EMBASE, and the Cochrane Library, for studies reporting OA prevalence by radiographic classification scales at a minimum of 10 years following ACLR with autograft. Studies were categorized as anatomic if they met or exceeded a score of 8 according the Anatomic ACL Reconstruction Scoring Checklist (AARSC), while those with a score less than 8 were categorized as non-anatomic/non-specified. Secondary outcomes included graft failure and measures of knee stability (KT-1000, Pivot Shift) and functional outcomes [Lysholm, Tegner, subjective and objective International Knee Documentation Committee (IKDC) scores]. OA prevalence on all radiographic scales was recorded and adapted to a normalized scale. RESULTS Twenty-six studies were included, of which 5 achieved a score of 8 on the AARSC. Using a normalized OA classification scale, 87 of 375 patients (23.2%) had diagnosed OA at a mean follow-up of 15.3 years after anatomic ACLR and 744 of 1696 patients (43.9%) had OA at mean follow-up of 15.9 years after non-anatomic/non-specified ACLR. The AARSC scores were 9.2 ± 1.3 for anatomic ACLR and 5.1 ± 1.1 for non-anatomic/non-specified ACLR. Secondary outcomes were relatively similar between techniques but inconsistently reported. CONCLUSIONS This study showed that anatomic ACLR, defined as an AARSC score ≥ 8, was associated with lower OA prevalence at long-term follow-up. Additional studies reporting long-term outcomes following anatomic ACLR are needed, as high-level studies of anatomic ACLR are lacking. The AARSC is a valuable resource in performing and evaluating anatomic ACLR. Anatomic ACLR, as defined by the AARSC, may reduce the long-term risk of post-traumatic OA following ACL injury to a greater extent than non-anatomic ACLR. LEVEL OF EVIDENCE IV.
Collapse
Affiliation(s)
- Benjamin B Rothrauff
- Department of Orthopaedic Surgery, UPMC Freddie Fu Sports Medicine Center, University of Pittsburgh, 3200 S. Water St., Pittsburgh, PA, 15203, USA
| | - Ahmed Jorge
- Department of Orthopaedic Surgery, UPMC Freddie Fu Sports Medicine Center, University of Pittsburgh, 3200 S. Water St., Pittsburgh, PA, 15203, USA
| | - Darren de Sa
- Department of Orthopaedic Surgery, UPMC Freddie Fu Sports Medicine Center, University of Pittsburgh, 3200 S. Water St., Pittsburgh, PA, 15203, USA
| | - Jeffrey Kay
- Division of Orthopaedic Surgery, Department of Surgery, McMaster University, Hamilton, ON, Canada
| | - Freddie H Fu
- Department of Orthopaedic Surgery, UPMC Freddie Fu Sports Medicine Center, University of Pittsburgh, 3200 S. Water St., Pittsburgh, PA, 15203, USA
| | - Volker Musahl
- Department of Orthopaedic Surgery, UPMC Freddie Fu Sports Medicine Center, University of Pittsburgh, 3200 S. Water St., Pittsburgh, PA, 15203, USA.
| |
Collapse
|
19
|
The single-suture technique for anterior cruciate ligament graft preparation provides similar stability as a three-suture technique: a biomechanical in vitro study in a porcine model. Arch Orthop Trauma Surg 2020; 140:511-516. [PMID: 31980876 PMCID: PMC7109177 DOI: 10.1007/s00402-020-03350-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/23/2019] [Indexed: 01/22/2023]
Abstract
PURPOSE Numerous techniques have been described for the tibial-sided graft preparation in anterior cruciate ligament (ACL) reconstruction. The use of less suture material for graft preparation is thought to improve ingrowth and to reduce the risk for infection. At the same time, the suture construct should be strong enough to resist the surgeon's pull during tensioning of the transplant. METHODS In total, 39 fresh-frozen procine deep flexor tendons were used and prepared as four-strand grafts. In the three-suture group (n = 19), graft preparation was performed using three tibial-sided sutures, with each tendon end sutured separately. In the one-suture group (n = 20), a modified graft preparation using only one tibial-sided suture was applied. Each sample underwent load-to-failure testing (Nmax) after cyclic pre-loading. To estimate intraoperative tension forces acting on the tibial-sided suture constructs, the maximal tension force of 26 volunteers on such a construct was measured using a load cell. RESULTS The biomechanical testing of the two different suture constructs showed a significantly higher load-to-failure for the three-suture group (711 N ± 91 N) compared to the one-suture group (347 N ± 24 N) (p = 0.0001). In both groups, the mode of failure was a tear of the suture in all samples. A failure of the suture-tendon interface was not observed in any case. The median maximal tension force on the construct applied by the 26 volunteers was 134 N (range 73-182 N). CONCLUSION The presented single-suture tendon graft preparation resisted to smaller failure loads than the conventional three-suture technique. However, no failures in the suture-tendon interface were seen and the failure loads observed were far beyond the tension forces that can be expected intraoperatively. Hence, the single-suture graft preparation technique may be a valuable alternative to the conventional technique.
Collapse
|
20
|
Superior knee flexor strength at 2 years with all-inside short-graft anterior cruciate ligament reconstruction vs a conventional hamstring technique. Knee Surg Sports Traumatol Arthrosc 2019; 27:3592-3598. [PMID: 30888448 DOI: 10.1007/s00167-019-05456-9] [Citation(s) in RCA: 32] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/01/2018] [Accepted: 02/28/2019] [Indexed: 01/30/2023]
Abstract
PURPOSE To compare the "all-inside technique" for anterior cruciate ligament (ACL) reconstruction using a short, quadrupled semitendinosus tendon (ST4) autograft and suspensory cortical fixation on both the femoral and tibial side vs the "conventional technique" using a semitendinosus/gracilis (ST/G) autograft fixed with a suspensory device on the femoral side and with an interference screw on the tibial side, in terms of clinical and functional outcomes. METHODS A total of 90 patients were enrolled, randomised into two groups, and prospectively followed. Group A comprised 45 patients treated with the all-inside technique and Group B included 45 patients treated with the conventional ACL technique (55 males, 35 females; mean age 28.7 ± 11.3 years). Patients completed the Lysholm knee score, the International Knee Documentation Committee (IKDC) score, the Knee Injury and Osteoarthritis Score (KOOS), and the Knee Society Score (KSS) preoperatively and at 2 years postoperatively. Anterior tibial translation measurement (KT-1000 arthrometer) and isokinetic testing of the operative vs non-operative limb were also conducted and the limb symmetry index (LSI) was determined. RESULTS At 24 months, the Lysholm, IKDC, KOOS, and KSS scores between the two groups were similar (n.s.). Anterior tibial translation between the operative and non-operative knee was also similar among the two groups (n.s.). Patients of Group A had significantly higher mean LSIs in terms of flexor peak torque (1.0 ± 0.1 vs 0.9 ± 0.1; p < 0.001), time-to-peak (0.9 ± 0.1 vs 0.8 ± 0.1; p < 0.001) and total work (0.9 ± 0.1 vs 0.8 ± 0.1; p < 0.001) at 180°/s, and significantly better mean LSI for isometric flexor/extensor ratio at 90° (1.1 ± 0.3 vs 0.8 ± 0.2; p < 0.001). CONCLUSION The all-inside ACL reconstruction with an ST4 autograft and cortical button fixation on both ends is a viable alternative to the conventional technique. It affords preservation of knee flexor strength, which is of advantage, especially when treating athletes with ACL injury. LEVEL OF EVIDENCE I.
Collapse
|
21
|
Lie MM, Risberg MA, Storheim K, Engebretsen L, Øiestad BE. What's the rate of knee osteoarthritis 10 years after anterior cruciate ligament injury? An updated systematic review. Br J Sports Med 2019; 53:1162-1167. [PMID: 30936063 DOI: 10.1136/bjsports-2018-099751] [Citation(s) in RCA: 109] [Impact Index Per Article: 21.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/05/2019] [Indexed: 12/31/2022]
Abstract
BACKGROUND This updated systematic review reports data from 2009 on the prevalence, and risk factors, for knee osteoarthritis (OA) more than 10 years after anterior cruciate ligament (ACL) tear. METHODS We systematically searched five databases (PubMed, EMBASE, AMED, Cinahl and SPORTDiscus) for prospective and retrospective studies published after 1 August 2008. Studies were included if they investigated participants with ACL tear (isolated or in combination with medial collateral ligament and/or meniscal injuries) and reported symptomatic and/or radiographic OA at a minimum of 10 years postinjury. We used a modified version of the Downs and Black checklist for methodological quality assessment and narrative synthesis to report results. The study protocol was registered in PROSPERO. RESULTS Forty-one studies were included. Low methodological quality was revealed in over half of the studies. At inclusion, age ranged from 23 to 38 years, and at follow-up from 31 to 51 years. Sample sizes ranged from 18 to 780 participants. The reported radiographic OA prevalence varied between 0% and 100% >10 years after injury, regardless of follow-up time. The studies with low and high methodological quality reported a prevalence of radiographic OA between 0%-100% and 1%-80%, respectively. One study reported symptomatic knee OA for the tibiofemoral (TF) joint (35%), and one study reported symptomatic knee OA for the patellofemoral (PF) joint (15%). Meniscectomy was the only consistent risk factor determined from the data synthesis. CONCLUSION Radiographic knee OA varied between 0% and 100% in line with our previous systematic review from 2009. Symptomatic and radiographic knee OA was differentiated in two studies only, with a reported symptomatic OA prevalence of 35% for the TF joint and 15% for PF joint. Future cohort studies need to include measurement of symptomatic knee OA in this patient group. PROSPERO REGISTRATION NUMBER CRD42016042693.
Collapse
Affiliation(s)
- Marthe Mehus Lie
- Institute of Physiotherapy, OsloMet - Oslo Metropolitan University, Oslo, Norway
| | - May Arna Risberg
- Department of Sport Medicine, Norwegian School of Sport Sciences, Oslo, Norway.,Division of Orthopedic Surgery, Oslo University Hospital, Oslo, Norway
| | - Kjersti Storheim
- Institute of Physiotherapy, OsloMet - Oslo Metropolitan University, Oslo, Norway.,Research and Communication unit for Musculoskeletal Health (FORMI), Oslo University Hospital, Oslo, Norway
| | - Lars Engebretsen
- Division of Orthopedic Surgery, Oslo University Hospital, Oslo, Norway.,Oslo Sports Trauma Research Center, Norwegian School of Sport Sciences, Oslo, Norway
| | - Britt Elin Øiestad
- Institute of Physiotherapy, OsloMet - Oslo Metropolitan University, Oslo, Norway
| |
Collapse
|
22
|
Fadensparende modifizierte Armierungstechnik für Kreuzbandtransplantate. ARTHROSKOPIE 2019. [DOI: 10.1007/s00142-018-0257-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
23
|
Winnisch M, Tiefenboeck TM, Steiger M, Komjati M, Hofbauer M, Kdolsky R. Long-term results after primary augmented repair of proximal tears of the anterior cruciate ligament with the Kennedy-LAD - Does it work? Knee 2018; 25:1115-1121. [PMID: 30193977 DOI: 10.1016/j.knee.2018.08.008] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/25/2017] [Revised: 05/10/2018] [Accepted: 08/13/2018] [Indexed: 02/02/2023]
Abstract
BACKGROUND The purpose of this study was to objectively evaluate the clinical functionality of the knee joint 30 years after surgical augmentation of the ACL with the "Kennedy Ligament Augmentation Device ®" (Kennedy LAD®). METHODS The patient collective consisted of 41 patients with an average age of 59.51 years (±10.18 standard deviation). Included were all patients treated operatively with a Kennedy LAD® augmented reattachment of the ACL at the Department of Trauma Surgery between 1983 and 1985. The state of the knee joint was evaluated with the following measures: Knee injury and Osteoarthritis Outcome Score, Lysholm Score, Short Form (36) Health Survey, International Knee Documentation Committee Score (IKDC, objective + subjective form) and Tegner Activity Scale. RESULTS Seven patients (17%) sustained a re-rupture of the Kennedy LAD® augmented ACL after a mean time of 16.28 years. Five of them underwent revision surgery. Another four patients (9.76%) showed an ACL insufficiency in clinical examination. The average IKDC Score was 74.14 ± 16.62, the average Lysholm Score was 86.83 ± 14.10, the average Tegner Activity Scale was 4.34 ± 1.11, and the average Knee injury and Osteoarthritis Outcome Score was 86.25 ± 11.64 at final follow-up. The mean Kellgren Lawrence Score of the operated knee was 2 ± 0.71. CONCLUSION An overall good outcome 30 years after primary ACL augmented repair with the Kennedy LAD® with an implant survival rate of 73% could be reached. These results therefore support the trend of ACL augmentation in selected cases. LEVEL OF EVIDENCE Retrospective study, Level IV.
Collapse
Affiliation(s)
- M Winnisch
- Department of Orthopedics and Trauma Surgery, Division of Trauma Surgery, Medical University of Vienna, Austria
| | - T M Tiefenboeck
- Department of Orthopedics and Trauma Surgery, Division of Trauma Surgery, Medical University of Vienna, Austria.
| | - M Steiger
- Department of Orthopedics and Trauma Surgery, Division of Trauma Surgery, Medical University of Vienna, Austria
| | - M Komjati
- Department of Orthopaedics, Sacred Heart Hospital of Jesus, Vienna, Austria
| | - M Hofbauer
- Department of Orthopedics and Trauma Surgery, Division of Trauma Surgery, Medical University of Vienna, Austria
| | - R Kdolsky
- Department of Orthopedics and Trauma Surgery, Division of Trauma Surgery, Medical University of Vienna, Austria
| |
Collapse
|
24
|
Geethan I, Santhosh Sahanand K, Ashwin Vijay PR, Rajan DV. Mechanical assessment of tripled hamstring tendon graft when using suspensory fixation for cruciate ligament reconstruction. J Exp Orthop 2018; 5:48. [PMID: 30483889 PMCID: PMC6258592 DOI: 10.1186/s40634-018-0163-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/01/2018] [Accepted: 11/13/2018] [Indexed: 12/28/2022] Open
Abstract
BACKGROUND Tripling semitendinosus tendon for ACL graft preparation facilitates creation of longer and thicker grafts. Our objective was to evaluate the mechanical difference between tripled tendon grafts, prepared by three methods, by comparing with quadrupled tendon graft. METHODS Bovine hind-foot hoof extensors were allocated to four groups. Group I had quadrupled graft construct. Tripled graft constructs were prepared by passing the tendon to the Endobutton CL loop and stitching the third strand to (i) the loop (in Group II) or (ii) to one strand(in Group III) or (iii)to loop and both tendon strands (in Group IV). The constructs were preloaded from 10 to 50 N at 0.1 Hz for 10 cycles, followed by 1000 cycles of sinusoidal loading between 50 and 250 N at a frequency of 0.5 Hz. The specimens were then subjected to load to failure test at the rate of 50 mm/min. Displacement with cyclic loading, load at failure and the mode of failure were noted. RESULTS The load at failure was 957 ± 23.30 N (Mean ± Standard Deviation) in Group I, 590.8 ± 24.40 N in Group II, 682.6 ± 59.28 N in Group III and 963.4 ± 21.72 N in Group IV. The displacement with cyclic loading was 1.13 ± 0.11 mm in Group I, 4.908 ± 0.55 mm in Group II, 1.822 ± 0.55 mm in Group III and 1. 126 ± .018 mm in Group IV. There was no significant difference between the Groups I and IV with respect to the load at failure and displacement (p > 0.05). The values were significantly different in Group II and Group III (p < 0.01), when compared to groups I and IV. CONCLUSIONS Tripled grafts have mechanical properties equivalent to quadrupled grafts only when the three strands are sutured together. Caution may be warranted when using suspensory fixation device with tripled tendons and the third strand must be securely attached to the loop of fixation device and to the other two strands.
Collapse
Affiliation(s)
- I Geethan
- Arthroscopy Centre, Trichy, GastroCare Hospital, 11th Cross East, Thillai Nagar, Thiruchirappalli, Tamil Nadu, India.
| | | | - P R Ashwin Vijay
- Ortho One Orthopaedic Speciality Center, Coimbatore, Tamil Nadu, India
| | - David V Rajan
- Ortho One Orthopaedic Speciality Center, Coimbatore, Tamil Nadu, India
| |
Collapse
|
25
|
Kwak YH, Lee S, Lee MC, Han HS. Anterior cruciate ligament reconstruction with quadriceps tendon-patellar bone allograft: matched case control study. BMC Musculoskelet Disord 2018; 19:45. [PMID: 29426312 PMCID: PMC5807733 DOI: 10.1186/s12891-018-1959-0] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/21/2017] [Accepted: 01/30/2018] [Indexed: 02/07/2023] Open
Abstract
Background Quadriceps tendon-patellar bone (QTPB) autograft is an excellent graft option with good clinical outcome. Use of QTPB autografts have increased because they minimize donor-site morbidity including anterior knee pain, while providing adequate mechanical strength. Although, there were many clinical results about allografts that used in anterior cruciate ligament (ACL) reconstruction, it have never been reported about the clinical outcome of ACL reconstruction with QTPB allograft. The purpose of this study is to evaluate the clinical outcome of ACL reconstruction with QTPB allograft and to compare with QTPB autograft. We hypothesized that ACL reconstruction with QTPB allograft had good functional outcomes and stability and no significant difference compared to the ACL reconstruction with QTPB autograft. Methods From February 2009 to January 2014, 213 cases who received ACL reconstruction with QTPB grafts were included. Forty-five patients who received ACL reconstruction with QTPB allograft were individually matched in age, sex, direction of the injured knee and body mass index (BMI) to a control group of 45 patients who received QTPB autograft. Clinical results were evaluated using International Knee Documentation Committee (IKDC) score, Lysholm score, Tegner scale, Knee injury and Osteoarthritis Outcome Score (KOOS) and ligament laxity. An average follow-up time was 31.2 months. Results The functional scores and ligament laxity improved from initial to the last visit in those with ACL reconstruction with QTPB allograft (p < 0.05). No significant statistical difference was found in clinical outcomes and complications including re-rupture between the QTPB allograft and autograft groups (p > 0.05). Laxity using anterior drawer test, Lachman test and KT-2000 showed no significant difference. No significant difference was found between the two groups in quadriceps peak extension torque, except at 60° per second at 6 months. Conclusion QTPB allograft achieved good clinical outcome with no difference compared with QTPB autograft. QTPB allograft for ACL reconstruction is promising alternative to selected and compliant patients. Long-term follow-up needs to further evaluate the clinical outcomes and complications including re-rupture rate.
Collapse
Affiliation(s)
- Yoon-Ho Kwak
- Seoul National University Hospital, Seoul, Republic of Korea
| | - Sahnghoon Lee
- Seoul National University Hospital, Seoul, Republic of Korea
| | - Myung Chul Lee
- Seoul National University Hospital, Seoul, Republic of Korea
| | - Hyuk-Soo Han
- Seoul National University Hospital, Seoul, Republic of Korea.
| |
Collapse
|
26
|
Cavaignac E, Marot V, Faruch M, Reina N, Murgier J, Accadbled F, Berard E, Chiron P. Hamstring Graft Incorporation According to the Length of the Graft Inside Tunnels. Am J Sports Med 2018; 46:348-356. [PMID: 29065271 DOI: 10.1177/0363546517733472] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Anterior cruciate ligament (ACL) reconstruction with a quadrupled semitendinosus (ST4) graft is an evolution of the standard technique with 2 hamstring tendons (semitendinosus + gracilis [STG]). However, there is no published comparison of how well these 2 types of hamstring grafts are incorporated into the bone tunnels. Because the ST4 graft is shorter, there is less graft material inside the tunnels. PURPOSE To use magnetic resonance imaging (MRI) to compare graft incorporation in the tibial bone tunnels 1 year after ACL reconstruction with either an STG graft or ST4 graft. STUDY DESIGN Cohort study; Level of evidence, 2. METHODS Sixty-two patients who underwent ACL reconstruction were enrolled prospectively: 31 with an ST4 graft and 31 with an STG graft. The same surgical technique, fixation method, and postoperative protocol were used in both groups. Graft incorporation and ligamentization were evaluated with MRI after 1 year of follow-up. The following parameters were evaluated: signal-to-noise quotient (SNQ), tibial tunnel enlargement, signal intensity at the bone-graft interface, and graft signal according to the Howell scale. The number of participants needed to show that the mean SNQ did not differ between the 2 techniques was 31 in each group (with a 1-sided alpha of 2.5% and a 1-sided beta of 10.0%). The Student t test was used to compare the distribution of continuous secondary endpoints. RESULTS The mean SNQ was 5.2 ± 4.5 for the STG group and 5.9 ± 3.7 for the ST4 group ( P = .5100). The mean tibial tunnel widening was 93.7% ± 51.7% for the STG group versus 80.0% ± 42.9% for the ST4 group ( P = .2605). The groups did not differ in signal intensity at the bone-graft interface ( P = .7502) or in graft signal according to the Howell scale ( P = .4544). CONCLUSION At the 1-year postoperative follow-up, incorporation and ligamentization of the STG and ST4 grafts were the same based on MRI analysis. The results were at least as good with the ST4 technique as with the standard STG technique in terms of incorporation and ligamentization.
Collapse
Affiliation(s)
- Etienne Cavaignac
- Department of Orthopedic Surgery and Trauma, Hôpital Pierre-Paul Riquet, Toulouse, France
| | - Vincent Marot
- Department of Orthopedic Surgery and Trauma, Hôpital Pierre-Paul Riquet, Toulouse, France
| | - Marie Faruch
- Department of Radiology, Centre Hospitalier Universitaire de Toulouse, Toulouse, France
| | - Nicolas Reina
- Department of Orthopedic Surgery and Trauma, Hôpital Pierre-Paul Riquet, Toulouse, France
| | - Jérôme Murgier
- Department of Orthopedic Surgery and Trauma, Hôpital Pierre-Paul Riquet, Toulouse, France
| | - Franck Accadbled
- Department of Orthopedic Surgery, Hôpital des Enfants, Toulouse, France
| | - Emilie Berard
- Department of Epidemiology, Health Economics and Public Health, UMR1027 INSERM-Université de Toulouse III, Centre Hospitalier Universitaire de Toulouse, Toulouse, France
| | - Philippe Chiron
- Department of Orthopedic Surgery and Trauma, Hôpital Pierre-Paul Riquet, Toulouse, France
| |
Collapse
|
27
|
Bhardwaj A, Solanki NS, Jain H, Raichandani K, Raichandani S, Daruwalla V. Comparison of outcome after ACL reconstruction in terms of subjective assessment of symptoms and function and clinical assessment of ligament stability. J Clin Orthop Trauma 2018; 9:172-174. [PMID: 29896023 PMCID: PMC5994999 DOI: 10.1016/j.jcot.2016.09.010] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/21/2016] [Revised: 08/21/2016] [Accepted: 09/24/2016] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND The knee joint is frequently involved in sports and other injuries with Anterior cruciate ligament being a very common ligament to be injured. The Lachman test, pivot-shift test, and instrumented knee laxity examination are frequently used and reported for evaluation of ACL reconstruction. The aim of this study is to examine and evaluate the relationships between the clinical assessment of ligament stability and subjective assessment of symptoms and function after ACL reconstruction. METHODS A total of 50 young and middle aged patients with unilateral knee ACL injury treated with ACL reconstruction using hamstring graft were evaluated for a minimum period of 1 year. Clinical assessment of ligament stability was done through Lachman and pivot-shift examination. Subjective variables of symptoms at follow-up included pain, swelling, instability and locking of knee. Subjective function at follow up included satisfaction with outcome, squatting, ascending or descending stairs, jumping, twisting and Lysholm score. RESULTS Lachman Examination at follow-up had no significant (P > .05) relationship with pain, swelling, instability, locking, squatting, ascending or descending stairs, jumping, twisting, satisfaction with outcome and Lysholm score. Pivot-shift examination at follow-up had significant associations with patient satisfaction (P = .04), instability of knee (P = .02), difficulty during twisting (P = .02) and Lysholm score (P = .01). CONCLUSION Pivot-shift examination is a better measure than Lachman examination or instrumented knee laxity as far as patients' functional outcome and overall satisfaction is concerned.
Collapse
Affiliation(s)
- Abhinav Bhardwaj
- Mahatma Gandhi Hospital, Dr. S.N. Medical College, Jodhpur, Rajasthan, India,Corresponding author.
| | | | - Hemant Jain
- Mahatma Gandhi Hospital, Dr. S.N. Medical College, Jodhpur, Rajasthan, India
| | - Kishore Raichandani
- Mahatma Gandhi Hospital, Dr. S.N. Medical College, Jodhpur, Rajasthan, India
| | - Surbhi Raichandani
- Mahatma Gandhi Hospital, Dr. S.N. Medical College, Jodhpur, Rajasthan, India
| | - Vistasp Daruwalla
- Wayne State University/Detroit Medical Center, Department of Radiology, 4201 St. Antoine, Detroit, MI 48201, USA
| |
Collapse
|
28
|
Outcome of Hamstring Autograft With Preserved Insertions Compared With Free Hamstring Autograft in Anterior Cruciate Ligament Surgery at 2-Year Follow-up. Arthroscopy 2017; 33:2208-2216. [PMID: 28969952 DOI: 10.1016/j.arthro.2017.06.040] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/25/2016] [Revised: 06/14/2017] [Accepted: 06/20/2017] [Indexed: 02/02/2023]
Abstract
PURPOSE To compare mechanical stability, functional outcome, and level of return to sports activity in patients undergoing anterior cruciate ligament (ACL) reconstruction with a free hamstring graft versus a graft with preserved insertions at 2-year follow-up. METHODS This study was a prospective, single-blind (the evaluator was blinded), randomized trial of 110 adult professional athletes who were randomly allocated into 2 groups. Group 1 consisted of 55 patients who underwent ACL reconstruction with hamstring tendon autograft with preserved insertions (technique 1), and group 2 consisted of 55 patients who underwent ACL reconstruction with free hamstring tendon autograft (technique 2). An anteromedial portal was used for drilling of the femoral tunnel in all cases. Patients were assessed for a minimum follow-up of 2 years with clinical tests, the Activities of Daily Living Function Scale and Sports Function Scale (Cincinnati knee score), knee arthrometer (KT-1000) testing, and the Tegner activity scale. RESULTS The average age of the patients was 27.0 ± 7.5 years in group 1 and 27.2 ± 5.7 years in group 2. At 24 months, the mean side-to-side difference by KT-1000 testing was 1.4 in group 1 and 2.2 in group 2 (P < .0001); the mean Cincinnati knee score (Activities of Daily Living Function Scale and Sports Function Scale) was 418.5 (median, 420; range, 400-420) and 406.8 (median, 420; range, 350-420), respectively (P < .0001); and the mean difference between the preinjury and postsurgery Tegner level of sports activity was 0.3 and 1.08, respectively (P = .027). CONCLUSIONS Although ACL reconstruction using hamstring autograft with preserved insertions resulted in statistically superior anterior stability, a better functional outcome, and a closer return to the preinjury level of sports activity as compared with free autograft, no clinically significant difference was proved. LEVEL OF EVIDENCE Level I, randomized controlled trial.
Collapse
|
29
|
Short-term complications in intra- and extra-articular anterior cruciate ligament reconstruction. Comparison with the literature on isolated intra-articular reconstruction. A multicenter study by the French Arthroscopy Society. Orthop Traumatol Surg Res 2017; 103:S231-S236. [PMID: 28917520 DOI: 10.1016/j.otsr.2017.09.006] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/02/2017] [Accepted: 08/23/2017] [Indexed: 02/02/2023]
Abstract
INTRODUCTION Lateral tenodesis (LT) is performed to limit the risk of iterative tear following anterior cruciate ligament (ACL) reconstruction in at-risk patients. By adding an extra procedure to isolated ACL graft, LT reconstruction increases operating time and may complicate postoperative course. The objective of the present study was to evaluate the rate of early complications. The study hypothesis was that associating ALL reconstruction to ACL reconstruction does not increase the complications rate found with isolated ACL reconstruction. MATERIAL AND METHODS A prospective multicenter study included 392 patients: 70% male; mean age, 29.9 years; treated by associated ACL and LT reconstruction. All adverse events were inventoried. RESULTS Mean hospital stay was 2 days, with 46% day-surgery. Walking was resumed at a mean 27 days, with an advantage for patients treated by the hamstring technique. The early postoperative complications rate was 12%, with 1.7% specifically implicating LT reconstruction: pain, hematoma, stiffness in flexion and extension, and infection. There was a 5% rate of surgical revision during the first year, predominantly comprising arthrolysis for extension deficit. The 1-year recurrence rate was 2.8%. DISCUSSION The complications rate for combined intra- and extra-articular reconstruction was no higher than for isolated intra-articular ACL reconstruction, with no increase in infection or stiffness rates. The rate of complications specific to ALL reconstruction was low, at 1.7%, and mainly involved fixation error causing lateral soft-tissue impingement. LEVEL OF EVIDENCE IV, prospective multicenter study.
Collapse
|
30
|
Imbert P, Lustig S, Steltzlen C, Batailler C, Colombet P, Dalmay F, Bertiaux S, D'ingrado P, Ehkirch FP, Louis ML, Pailhé R, Panisset JC, Schlaterrer B, Sonnery-Cottet B, Sigwalt L, Saragaglia D, Lutz C. Midterm results of combined intra- and extra-articular ACL reconstruction compared to historical ACL reconstruction data. Multicenter study of the French Arthroscopy Society. Orthop Traumatol Surg Res 2017; 103:S215-S221. [PMID: 28917521 DOI: 10.1016/j.otsr.2017.09.005] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/02/2017] [Accepted: 08/23/2017] [Indexed: 02/02/2023]
Abstract
INTRODUCTION During anterior cruciate ligament (ACL) reconstruction procedures, anterolateral reconstruction (ALR) can also be performed to improve the knee's rotational stability. However, the effectiveness of this supplemental technique and its impact on the risk of retears and on the onset of secondary degenerative changesare controversial. HYPOTHESIS ALR improves control over the pivot shift, reduces the retear risk and delays the appearance of secondary degenerative lesions. MATERIAL AND METHODS Clinical examination, knee laxity measurements and X-ray evaluations were done in 478 patients with more than 3years' follow-up after combined ACL and ALR from 11 participating hospitals. The mean patient age at the time of surgery was 28years. Eighty-eight percent of the patients participated in pivot sports and 45% were competitive athletes. The findings of this study were compared to historical isolated ACL reconstruction data. RESULTS The average follow-up was 6.8years. No detectable pivot shift was found in 83% of patients, while 12.8% of patient had a smooth glide. The side-to-side difference in anteroposterior knee laxity with maximum manual force was less than 3mm in 66% of patients and less than 5mm in 95%. The retear rate was 5.4%, with half of these patients undergoing revision ACL surgery. Secondary meniscus damage requiring surgery occurred in 6.3% of patients; the radiological osteoarthritis rate was 17.5%. DISCUSSION When compared to historical ACL reconstruction data, combined intra- and extra-articular reconstruction does not increase the complication rate. At a mean follow-up of 6.8years, it provides better control over the pivot shift along with a low retear rate and low occurrence of secondary meniscus injuries. LEVEL OF EVIDENCE IV, multicenter study.
Collapse
Affiliation(s)
- P Imbert
- ICAPS, 87, avenue Archimède, 83700 St-Raphael, France.
| | - S Lustig
- Centre Albert Trillat, hôpital de la Croix-Rousse, 103, grande rue de la Croix-Rousse, 69004 Lyon, France
| | - C Steltzlen
- Centre hospitalier de Versailles André-Mignot, 177, rue de Versailles, 78150 Le Chesnay, France
| | - C Batailler
- Centre Albert Trillat, hôpital de la Croix-Rousse, 103, grande rue de la Croix-Rousse, 69004 Lyon, France
| | - P Colombet
- Centre de chirurgie orthopédique et sportive, 2, rue Negrevergne, 33700 Mérignac, France
| | - F Dalmay
- 2UMR Inserm 1094 NET, 2, rue du Docteur-Marcland, 87025 Limoges cedex, France
| | - S Bertiaux
- Hôpital privé de l'Estuaire, 505, rue Irène-Joliot-Curie, 76620 le Havre, France
| | - P D'ingrado
- Clinique du parc, 155, boulevard de Stalingrad, 69006 Lyon, France
| | - F P Ehkirch
- Clinique Maussins-Nollet, 67, rue de Romain-Ville, 75019 Paris, France
| | - M L Louis
- Centre ICOS, 463, rue Paradis, 13008 Marseille, France
| | - R Pailhé
- Clinique universitaire de chirurgie orthopédique et de traumatologie du sport, CHU de Grenoble, hôpital Sud, avenue de Kimberley, 38130 Échirolles, France
| | - J C Panisset
- Centre Ostéo-articulaire des Cèdres, 5, rue des Tropiques, Parc Sud Galaxie, 38130 Échirolles, France
| | | | - B Sonnery-Cottet
- Centre orthopédique Santy, 24, avenue Paul-Santy, 69008 Lyon, France
| | - L Sigwalt
- Clinique universitaire de chirurgie orthopédique et de traumatologie du sport, CHU de Grenoble, hôpital Sud, avenue de Kimberley, 38130 Échirolles, France
| | - D Saragaglia
- Clinique universitaire de chirurgie orthopédique et de traumatologie du sport, CHU de Grenoble, hôpital Sud, avenue de Kimberley, 38130 Échirolles, France
| | - C Lutz
- ICOSS, 50, avenue des Vosges, 67000 Strasbourg, France
| | | |
Collapse
|
31
|
Chiba D, Tsuda E, Sasaki S, Liu X, Ishibashi Y. Anthropometric and Skeletal Parameters Predict 2-Strand Semitendinosus Tendon Size in Double-Bundle Anterior Cruciate Ligament Reconstruction. Orthop J Sports Med 2017; 5:2325967117720148. [PMID: 28812041 PMCID: PMC5542154 DOI: 10.1177/2325967117720148] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
Abstract
Background: Few studies have examined whether skeletal parameters predict hamstring graft size during anterior cruciate ligament reconstruction (ACLR). Purpose/Hypothesis: The purpose of this study was to examine whether preoperative anthropometric and radiographic skeletal parameters could predict hamstring graft size during ACLR. We hypothesized that both anthropometric and skeletal parameters can be used to predict graft size in our double-bundle procedure and that the use of skeletal parameters will improve the accuracy of graft size prediction. Study Design: Cross-sectional study; Level of evidence, 3. Methods: A total of 200 patients were recruited and underwent double-bundle ACLR using a semitendinosus (ST) graft. The harvested tendon was measured to determine graft length (GL) and then split at its midpoint. The graft diameters of the anteromedial (GDAM) and posterolateral bundles (GDPL) were measured at the femoral aspect of the 2-stranded graft. The mean diameters of both bundles were included in the analysis. On the coronal radiograph, femorotibial angle (FTA), femoral interepicondylar distance (IED), and tibial plateau width (coronal tibial width [CTW]) were measured. Blumensaat line length (BLL) and the lateral tibial width (LTW) were measured on the lateral radiograph. A linear regression analysis was conducted using graft size as the dependent variable and age, sex, height, weight, Tegner activity score, and skeletal parameters as the independent variables. Results: Mean GL was 258.9 ± 21.9 mm, GDAM was 5.9 ± 0.5 mm, and GDPL was 5.7 ± 0.6 mm. Single regression analysis showed that GL was significantly predicted by sex, height, weight, Tegner activity score, IED, CTW, BLL, and LTW (R2 range, 0.033-0.342). GD was predicted by sex, height, weight, IED, CTW, BLL, and LTW (R2 range, 0.094-0.207). Stepwise multiple linear regression analysis significantly confirmed sex, height, and age as the variables to comprehensively predict GL (R2 = 0.384). With regard to GD, stepwise multiple regression confirmed height and IED as significant variables (R2 = 0.224). Conclusion: Both preoperative anthropometric and radiographic parameters on plain radiographs were able to predict harvested GL and 2-strand GD. Multivariate regression slightly improved the prediction of graft dimensions compared with univariate regression.
Collapse
Affiliation(s)
- Daisuke Chiba
- Department of Orthopaedic Surgery, Hirosaki University Graduate School of Medicine, Aomori, Japan
| | - Eiichi Tsuda
- Department of Rehabilitation Medicine, Hirosaki University Graduate School of Medicine, Aomori, Japan
| | - Shizuka Sasaki
- Department of Orthopaedic Surgery, Hirosaki University Graduate School of Medicine, Aomori, Japan
| | - Xizhe Liu
- Department of Orthopaedic Surgery, Hirosaki University Graduate School of Medicine, Aomori, Japan
| | - Yasuyuki Ishibashi
- Department of Orthopaedic Surgery, Hirosaki University Graduate School of Medicine, Aomori, Japan
| |
Collapse
|
32
|
Browning WM, Kluczynski MA, Curatolo C, Marzo JM. Suspensory Versus Aperture Fixation of a Quadrupled Hamstring Tendon Autograft in Anterior Cruciate Ligament Reconstruction: A Meta-analysis. Am J Sports Med 2017; 45:2418-2427. [PMID: 28068159 DOI: 10.1177/0363546516680995] [Citation(s) in RCA: 42] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Hamstring grafts have become a popular choice for anterior cruciate ligament (ACL) reconstruction; however, the most effective means of fixation of these soft tissue grafts is unknown. PURPOSE To determine whether suspensory or aperture fixation of hamstring tendon autografts provides better stability and clinical outcomes in ACL reconstruction. STUDY DESIGN Meta-analysis. METHODS A literature search of studies reporting single-bundle ACL reconstructions using 4-stranded hamstring tendon autografts with aperture or suspensory fixation with a minimum 24-month follow-up was conducted. Stability and clinical outcomes were compared for aperture versus suspensory fixation. Knee stability was measured with the Lachman or pivot-shift test or KT-1000 arthrometer side-to-side difference (SSD), and outcomes were determined with the International Knee Documentation Committee (IKDC), Tegner, and Lysholm scores as well as graft failures. A random-effects model with a pooled estimate for the between-study variance was used to estimate proportions or means for each outcome and its corresponding 95% CI. RESULTS Forty-one studies were included, of which 20 utilized suspensory fixation techniques and 21 utilized aperture fixation techniques. A >3-mm SSD was seen more often in the aperture group than the suspensory group, which was statistically significant ( P < .0001), but there was no significant difference between groups for a >5-mm SSD ( P = .53). The aperture group demonstrated significantly more graft ruptures than did the suspensory group ( P = .03). There were no statistically significant differences in Lachman grade 0 ( P = .76), grade 1 ( P = .89), and grade 2 ( P = .55) or pivot-shift grade 0 ( P = .72), grade 1 ( P = .97), and grade 2 ( P = .28). There was no statistically significant difference in mean continuous IKDC ( P = .80), Tegner ( P = .34), or Lysholm ( P = .84) scores. CONCLUSION This meta-analysis demonstrated improved overall arthrometric stability and fewer graft ruptures using suspensory fixation compared with aperture fixation of a quadrupled hamstring tendon autograft in ACL reconstruction. There were no differences in IKDC, Lysholm, Lachman, and pivot-shift outcomes between suspensory and aperture fixation.
Collapse
Affiliation(s)
| | - Melissa A Kluczynski
- Department of Orthopaedics, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, Buffalo, New York, USA
| | - Christian Curatolo
- Department of Orthopaedics, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, Buffalo, New York, USA
| | - John M Marzo
- Department of Orthopaedics, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, Buffalo, New York, USA
| |
Collapse
|
33
|
Anterior cruciate ligament reconstruction tunnel size: causes of tunnel enlargement and implications for single versus two-stage revision reconstruction. Skeletal Radiol 2017; 46:161-169. [PMID: 27885380 DOI: 10.1007/s00256-016-2535-z] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/15/2015] [Revised: 11/07/2016] [Accepted: 11/14/2016] [Indexed: 02/02/2023]
Abstract
Anterior cruciate ligament (ACL) reconstructions have increased over the past 25 years. The increased incidence of ACL reconstructions has translated into a larger number of graft failures and revision ACL procedures. It is important to understand the causes of graft failure when evaluating for a revision ACL reconstruction and to appreciate changes in tunnel anatomy over time prior to planning revision surgery. In this manuscript, tunnel size for ACL reconstruction and implications for single-stage versus two-stage revision ACL reconstruction will be discussed, as well as causes of tunnel enlargement, including mechanical and biological factors.
Collapse
|
34
|
Lack of stability at more than 12 months of follow-up after anterior cruciate ligament reconstruction using all-inside quadruple-stranded semitendinosus graft with adjustable cortical button fixation in both femoral and tibial sides. Orthop Traumatol Surg Res 2016; 102:867-872. [PMID: 27717747 DOI: 10.1016/j.otsr.2016.08.011] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/09/2016] [Revised: 07/25/2016] [Accepted: 08/24/2016] [Indexed: 02/02/2023]
Abstract
INTRODUCTION The use of the semitendinosus tendon alone for anterior cruciate ligament reconstruction keeps the gracilis muscle intact and decreases anterior pain in comparison with the use of the patellar tendon. Recently, Lubowitz described a new all-inside technique with an ST4 tendon fixed with a cortical button in both femoral and tibial sides. We hypothesized that this type of graft with cortical button fixation provides well-controlled residual anterior tibial translation (<3mm). The aim of this study was to assess the results obtained with this technique in terms of laxity and IKDC score at more than 1 year of follow-up. MATERIAL AND METHODS We performed a prospective single-center study to evaluate the results with this procedure with at least 1 year of follow-up. The primary endpoint was the objective IKDC score and side-to-side anterior tibial translation difference. The secondary endpoint was the subjective assessment using the subjective IKDC and Lysholm scores. Tunnel positioning was assessed using the Aglietti criteria. RESULTS Thirty-five patients were included and reviewed with a mean follow-up of 19.7 months. Sixty-three percent of the patients were male and the mean age at the procedure was 28 years. The IKDC score was A or B in 43% of the patients and C or D in 57%; 54% of the patients had a residual side-to-side anterior tibial translation difference less than 3mm and 29% presented significant pivot shift (grade C or D). Five patients underwent revision surgery, including one for rupture of the ACL reconstruction. The meniscal status did not influence postoperative laxity and the IKDC grade. DISCUSSION Our hypothesis was not verified and the postoperative stability of the knee was insufficient. Postoperative side-to-side anterior tibial translation difference remained greater than 3mm for 16 patients and the analysis seems to indicate that the distal cortical fixation of the graft with an adjusted loop is insufficient. LEVEL OF EVIDENCE Prospective study - Level IV.
Collapse
|
35
|
Abstract
The pivot-shift test is an important examination to assess the rotational laxity in the anterior cruciate ligament (ACL) injured and reconstructed knees. Because this examination is related to subjective knee function, we may still see cases that have residual rotational laxity after ACL reconstruction. Quantitative evaluation of the pivot-shift test is preferable to the clinical pivot-shift test but is difficult to attain mainly due to complicated movements of the pivot-shift. The electromagnetic tracking system was developed to evaluate knee kinematics during the pivot-shift, providing information related to 6-degree-of-freedom knee kinematics with a high sampling rate. Through this device, the abnormal movement of the pivot-shift is characterized in two phases: an increased anterior tibial translation and a boosted acceleration of tibial posterior reduction. Since its invention, this system has been utilized to assess rotational laxity for clinical follow-up and research after the ACL reconstruction.
Collapse
|
36
|
Wordeman SC, Hewett TE. Research-Based and Clinical Considerations for Effective Neuromuscular Training to Prevent Second Anterior Cruciate Ligament Injury. OPER TECHN SPORT MED 2016. [DOI: 10.1053/j.otsm.2015.09.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
37
|
Smith CR, Lenhart RL, Kaiser J, Vignos M, Thelen DG. Influence of Ligament Properties on Tibiofemoral Mechanics in Walking. J Knee Surg 2016; 29:99-106. [PMID: 26408997 PMCID: PMC4755512 DOI: 10.1055/s-0035-1558858] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Computational knee models provide a powerful platform to investigate the effects of injury and surgery on functional knee behavior. The objective of this study was to use a multibody knee model to investigate the influence of ligament properties on tibiofemoral kinematics and cartilage contact pressures in the stance phase of walking. The knee model included 14 ligament bundles and articular cartilage contact acting across the tibiofemoral and patellofemoral joints. The knee was incorporated into a lower extremity musculoskeletal model and was used to simulate knee mechanics during the stance phase of normal walking. A Monte Carlo approach was employed to assess the influence of ligament stiffness and reference strain on knee mechanics. The anterior cruciate ligament (ACL), medial collateral ligament (MCL), and posterior capsule properties exhibited significant influence on anterior tibial translation at heel strike, with the ACL acting as the primary restraint to anterior translation in mid-stance. The MCL and lateral collateral ligament (LCL) exhibited the greatest influence on tibial rotation from heel strike through mid-stance. Simulated tibial plateau contact location was dependent on the ACL, MCL, and LCL properties, while pressure magnitudes were most dependent on the ACL. A decrease in ACL stiffness or reference strain significantly increased the average contact pressure in mid-stance, with the pressure migrating posteriorly on the medial tibial plateau. These ligament-dependent shifts in tibiofemoral cartilage contact during walking are potentially relevant to consider when investigating the causes of early-onset osteoarthritis following knee ligament injury and surgical treatment.
Collapse
Affiliation(s)
- Colin R. Smith
- Department of Mechanical Engineering, University of Wisconsin-Madison, Madison, WI
| | - Rachel L. Lenhart
- Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, WI
| | - Jarred Kaiser
- Department of Mechanical Engineering, University of Wisconsin-Madison, Madison, WI
| | - Mike Vignos
- Department of Mechanical Engineering, University of Wisconsin-Madison, Madison, WI
| | - Darryl G. Thelen
- Department of Mechanical Engineering, University of Wisconsin-Madison, Madison, WI,Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, WI,Department of Orthopedics and Rehabilitation, University of Wisconsin-Madison, Madison, WI,Address Correspondence to: Darryl G. Thelen, Ph.D., Department of Mechanical Engineering, University of Wisconsin-Madison, Madison, WI 53706, Phone: 608-262-1902, Fax: 608-265-2316,
| |
Collapse
|
38
|
Minimally invasive semitendinosus tendon harvesting from the popliteal fossa versus conventional hamstring tendon harvesting for ACL reconstruction: A prospective, randomised controlled trial in 100 patients. Knee 2016; 23:106-10. [PMID: 26753501 DOI: 10.1016/j.knee.2015.09.001] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/30/2015] [Revised: 08/01/2015] [Accepted: 09/01/2015] [Indexed: 02/02/2023]
Abstract
BACKGROUND This study aims to compare a technique for hamstring tendon harvesting from a postero-medial incision in the popliteal fossa with the conventional method. METHODS One hundred patients who underwent anterior cruciate ligament (ACL)-reconstruction were randomised to either have their tendon graft harvested from postero-medial (group 1) or via an antero-medial approach (group 2). Time for tendon harvest, length of skin incision and duration of tendon harvest were recorded as well as complications and sensory disturbances in the lower leg. Pain scores were documented on the VAS scale. RESULTS Time for tendon harvesting averaged one minute 23 s in group 1 versus five minutes 20 s in group 2 (p<0.01). The skin incision measured 21 mm (group 1) versus 49 mm in group 2 (p<0.01). The length of the harvested tendon averaged 272 mm (group 1) and 292 mm in group 2 (p<0.01). There was one superficial wound infection in group 2 and none in group 1. Postoperative pain scores were similar in both groups. None of the patients in group 1 reported sensory disturbance in the lower leg, whilst seven patients in group 2 were found to have reduced sensation in the distribution of the saphenous nerve postoperatively (p<0.01). CONCLUSION This study confirms that harvesting the semitendinosus tendon from postero-medial is quicker, results in a shorter scar and reduces the risk of injury to branches of the saphenous nerve. However, harvesting the tendon from postero-medial resulted in a shorter tendon graft. LEVEL OF EVIDENCE Level I (Randomised, controlled trial).
Collapse
|
39
|
Hart A, Han Y, Martineau PA. The Apex of the Deep Cartilage: A Landmark and New Technique to Help Identify Femoral Tunnel Placement in Anterior Cruciate Ligament Reconstruction. Arthroscopy 2015; 31:1777-83. [PMID: 25980920 DOI: 10.1016/j.arthro.2015.03.026] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/31/2014] [Revised: 02/24/2015] [Accepted: 03/17/2015] [Indexed: 02/02/2023]
Abstract
PURPOSE The purpose of this study was to evaluate the apex of the deep cartilage (ADC) as a landmark to help guide femoral tunnel placement during anatomic single-bundle anterior cruciate ligament (ACL) reconstruction. Our secondary purpose was to assess whether or not the endoscopic transtibial femoral offset drill guide could reach the center of the ACL's femoral footprint. METHODS Eight formalin-injected cadaveric knees were dissected and the center of the ACL femoral footprints identified. The ADC was selected as an easily identifiable landmark during arthroscopy and was used to reference the position of the ACL femoral footprint with the knee flexed at 90°. Next, a 7-mm transtibial femoral ACL drill guide was used to engage the posterior aspect of the lateral condyle at the level of the femoral footprint. This position was marked, and the distance from the center of the femoral footprint was recorded for each specimen. Descriptive statistics were used to report our measurements. RESULTS The median high and shallow measurements were 3 mm (range, 1 to 4 mm) and 12 mm (range, 11 to 17 mm), respectively. The femoral offset guide never reached the center of the femoral footprint in all specimens; the median distance between the 2 measurements was 4.5 mm (range, 2 to 9 mm). CONCLUSIONS If the anatomy is difficult to delineate at the time of reconstruction, our study suggests using the ADC as a landmark to guide anatomic placement. The dissection of 8 cadavers showed that the center of the ACL femoral footprint had a median position of 3 mm high and 12 mm shallow to the ADC. We also showed that the transtibial femoral offset guide did not reach the center of the ACL footprint on all specimens and should therefore not be used for anatomic ACL reconstruction. CLINICAL RELEVANCE Current commercially available transtibial femoral offset guides cannot reach the center of the ACL's femoral footprint and therefore should not be used. Alternative techniques, such as referencing from the ADC through an anteromedial (AM) portal, are recommended.
Collapse
Affiliation(s)
- Adam Hart
- Division of Orthopaedic Surgery, McGill University Health Centre, Montreal, Quebec, Canada.
| | - Yung Han
- Division of Orthopaedic Surgery, McGill University Health Centre, Montreal, Quebec, Canada
| | - Paul A Martineau
- Division of Orthopaedic Surgery, McGill University Health Centre, Montreal, Quebec, Canada
| |
Collapse
|
40
|
Nuelle CW, Cook JL, Gallizzi MA, Smith PA. Posterior single-incision semitendinosus harvest for a quadrupled anterior cruciate ligament graft construct: determination of graft length and diameter based on patient sex, height, weight, and body mass index. Arthroscopy 2015; 31:684-90. [PMID: 25522679 DOI: 10.1016/j.arthro.2014.10.013] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/21/2014] [Revised: 10/10/2014] [Accepted: 10/24/2014] [Indexed: 02/02/2023]
Abstract
PURPOSE This study aimed to determine final graft length and diameter for a quadrupled semitendinosus anterior cruciate ligament (ACL) construct harvested from a single-incision posterior approach with correlation to preoperative patient variables of sex, height, weight, and body mass index (BMI). METHODS This was a retrospective review of data collected prospectively on 60 patients undergoing all-inside quadrupled semitendinosus autograft ACL reconstruction. RESULTS The mean values of the final quadrupled constructs were a length of 70.3 mm and a diameter of 9.0 mm. Separated based on sex, female versus male final mean graft length was 68.1 mm versus 71.7 mm, and final mean graft diameter was 8.6 mm and 9.3 mm, respectively. In both sexes, patient height and weight were strongly correlated to final construct diameter (r = 0.60 and r = 0.56) and length (r = 0.47 and r = 0.44), respectively. CONCLUSIONS A single-incision posterior harvest approach allowed for retrieval of semitendinosis tendon autografts of sufficient dimension to allow for construction of quadrupled ACL grafts of a diameter of 8 mm or more in 95% of cases. In addition, desired graft length was achieved in all cases. Graft dimensions had moderately strong direct correlations to patient height and weight, with significant size differences noted between the sexes. We believe this to be helpful data for surgeons who might consider performing a quadrupled semitendinosus autograft ACL reconstruction. LEVEL OF EVIDENCE Level IV, therapeutic case series.
Collapse
Affiliation(s)
- Clayton W Nuelle
- Department of Orthopaedic Surgery, University of Missouri, Columbia, Missouri, U.S.A
| | - James L Cook
- Department of Orthopaedic Surgery, University of Missouri, Columbia, Missouri, U.S.A
| | - Michael A Gallizzi
- Department of Orthopaedic Surgery, University of Missouri, Columbia, Missouri, U.S.A
| | | |
Collapse
|
41
|
Filardo G, Kon E, Tentoni F, Andriolo L, Di Martino A, Busacca M, Di Matteo B, Marcacci M. Anterior cruciate ligament injury: post-traumatic bone marrow oedema correlates with long-term prognosis. INTERNATIONAL ORTHOPAEDICS 2015; 40:183-90. [PMID: 25653174 DOI: 10.1007/s00264-015-2672-3] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/03/2014] [Accepted: 01/04/2015] [Indexed: 11/28/2022]
Abstract
PURPOSE Bone marrow oedema (BME) in the knee is a feature of several pathological conditions, and it has been described with high frequency in patients with acute anterior cruciate ligament (ACL) injury. The aim of this study is to evaluate the significance of BME, assessed in MRIs performed for ACL injury, with regards to clinical outcome and return to sport. METHODS A total of 134 patients (98 men, 36 women) with ACL tear and MRI knee scan within six months from trauma were analysed. The presence of BME was evaluated on MRI images considering: extension and hyperintensity, the WORMS score oedema classification, and measuring the BME area. The clinical results were documented by IKDC-subjective score and the sport activity level by Tegner score at a minimum of five years follow up. RESULTS BME was present in 74 knees (55.2 %), with a mean area of 523 ± 370 mm². The presence of BME showed a gradual decrease over time (p = 0.008), being detectable in MRIs performed more than three months after trauma in just 25.0 % of cases. Although 54 % of the patients without BME after three months returned to their previous sport level, no patients with oedema reached a full sport recovery (p = 0.01). In the group that underwent ACL reconstruction, the BME area was significantly correlated with a return to the previous sport level at the mid/long-term follow-up (p = 0.038). CONCLUSIONS BME is a common finding, which decreases over time after injury. However, when BME is still detectable it correlates with clinical prognosis, and even in sport-active patients undergoing ACL reconstruction, a higher BME area is a negative predictive factor for a successful outcome at the mid/long-term follow-up.
Collapse
Affiliation(s)
- Giuseppe Filardo
- II Orthopaedic and Traumatologic Clinic-Biomechanics and Technology Innovation Laboratory, Rizzoli Orthopaedic Institute, Via Di Barbiano, 1/10, 40136, Bologna, Italy
| | - Elizaveta Kon
- Nano-Biotechnology Laboratory, Rizzoli Orthopaedic Institute, Bologna, Italy
| | - Francesco Tentoni
- II Orthopaedic and Traumatologic Clinic-Biomechanics and Technology Innovation Laboratory, Rizzoli Orthopaedic Institute, Via Di Barbiano, 1/10, 40136, Bologna, Italy
| | - Luca Andriolo
- II Orthopaedic and Traumatologic Clinic-Biomechanics and Technology Innovation Laboratory, Rizzoli Orthopaedic Institute, Via Di Barbiano, 1/10, 40136, Bologna, Italy
| | - Alessandro Di Martino
- II Orthopaedic and Traumatologic Clinic-Biomechanics and Technology Innovation Laboratory, Rizzoli Orthopaedic Institute, Via Di Barbiano, 1/10, 40136, Bologna, Italy
| | - Maurizio Busacca
- Radiology and Diagnostic Imaging Department, Rizzoli Orthopaedic Institute, Bologna, Italy
| | - Berardo Di Matteo
- II Orthopaedic and Traumatologic Clinic-Biomechanics and Technology Innovation Laboratory, Rizzoli Orthopaedic Institute, Via Di Barbiano, 1/10, 40136, Bologna, Italy.
| | - Maurilio Marcacci
- II Orthopaedic and Traumatologic Clinic-Biomechanics and Technology Innovation Laboratory, Rizzoli Orthopaedic Institute, Via Di Barbiano, 1/10, 40136, Bologna, Italy
| |
Collapse
|
42
|
A comparison of the anteromedial and transtibial drilling technique in ACL reconstruction after a short-term follow-up. Arch Orthop Trauma Surg 2014; 134:963-9. [PMID: 24770982 DOI: 10.1007/s00402-014-1996-6] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/08/2013] [Indexed: 12/21/2022]
Abstract
INTRODUCTION The purpose of this study was to compare clinical and radiological outcomes of patients who underwent single-bundle anterior cruciate ligament (ACL) reconstruction with anteromedial portal (AMP) and transtibial (TT) techniques. MATERIALS AND METHODS Arthroscopic single-bundle ACL reconstruction was performed using AMP technique in 34 patients and TT technique in 30 patients. The patients were evaluated retrospectively. Aperture fixation was used for femoral fixation, and absorbable screws and U staples were used for tibial fixation of the graft. Pivot shift test, Lachman test, Lysholm, Tegner, and International Knee Documentation Committee (IKDC-2000) scoring systems were used in the clinical and functional evaluation of patients before and after the surgery. Time to return sports and activity level were assessed. In the radiological evaluation of non-anatomic bone tunnel placement, the criteria developed by lllingworth et al. were used. The mean duration of follow-up was 20.4 and 24.6 months in the AMP and TT groups, respectively. RESULTS There was a significant difference between the AMP group (86.7 %) and the TT (14.7 %) group in terms of anatomical placement of the femoral tunnels and grafts (p < 0.001). No significant difference was observed between the two groups in terms of the Pivot shift test, Lachman test, Lysholm, Tegner, and IKDC scores, and activity level (p > 0.05). The patients in the AMP group returned to sports 1.5 months earlier on average (p < 0.001). CONCLUSIONS It was shown that AMP technique was superior to the TT technique in providing anatomical placement of the graft and in recovery time to return sports; however, there was no difference between groups in early periods in terms of the clinical and functional outcomes.
Collapse
|
43
|
Septic arthritis in ACL reconstruction surgery with hamstring autografts. Eleven years of experience. Knee 2014; 21:717-20. [PMID: 24588907 DOI: 10.1016/j.knee.2014.01.007] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/11/2013] [Revised: 12/27/2013] [Accepted: 01/30/2014] [Indexed: 02/02/2023]
Abstract
BACKGROUND Knee joint infection after ACL reconstruction is a rare complication with a low reported incidence, but the consequences can be devastating. The purpose of the study was to determine the incidence of septic arthritis after primary ACL reconstruction with hamstring auto-graft and the risk factors that may be associated. METHOD A retrospective study of all primary ACL reconstruction from January 2000 to May 2011. Electronic medical records were reviewed to determine the number of infections, operating time, associated procedure, time of presentation after surgery, infection treatment, microbiological cultures and graft retention. At the end of the follow-up (18-108months) a functional assessment of all the infected patients was performed using the Lysholm score with the Lysholm score. RESULTS We analyzed 1564 cases of primary ACL reconstruction with hamstring autograft, of which seven cases were diagnosed with postoperative joint infection (incidence rate of 0.45%). The infectious agent most frequently isolated was a coagulase-negative Staphylococcus. Neither intraoperative factors nor age correlated with the development of the infection. The average Lysholm score was 95 points (range 89-100 points). All but two patients retained their reconstructed ACL. The results of the five patients in which the graft was preserved were significantly better than the two patients that had their grafts removed (p=0.03). CONCLUSION We conclude that septic arthritis post ACL reconstruction has a low incidence rate, which if handled at an early stage allows the patients a satisfactory return to their previous activities. Graft retention is important to obtain better functional results. LEVEL OF EVIDENCE IV.
Collapse
|
44
|
Can rotatory knee laxity be predicted in isolated anterior cruciate ligament surgery? INTERNATIONAL ORTHOPAEDICS 2014; 38:1167-72. [PMID: 24477475 DOI: 10.1007/s00264-014-2287-0] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/18/2013] [Accepted: 01/13/2014] [Indexed: 12/12/2022]
Abstract
PURPOSE Despite the overall success of the surgical anterior cruciate ligament (ACL) reconstruction, some patients still present with instability symptoms even after the surgery, mainly due to the presence of associated lesions. At present, the pivot shift test has been reported to be the benchmark to assess rotatory knee laxity. The purpose of this study was to quantitatively evaluate rotatory knee laxity at time-zero in order to determine whether detected post-reconstruction laxity was predictable by its value measured before the reconstruction, which was hypothized to be influenced by the presence of associated lesions. METHODS Rotatory knee laxity was retrospectively analysed in 42 patients, including two different ACL reconstructions. The maximal anterior displacement and the absolute value of the posterior acceleration reached during the reduction of the tibial lateral compartment were intra-operatively acquired by using a navigation system and identified as discriminating parameters. For each parameter, statistical linear regression analysis (line slope and intercept) was performed between pre- and post-reconstruction values. RESULTS No statistically significant influence of the initial posterior acceleration on the post-reconstruction outcome was found (line slope, p > 0.05), although a statistically significant line intercept was indeed identified (p < 0.001). A statistically significant influence on the surgery outcome was instead found for the initial value of the anterior tibial displacement (line slope = 0.39, p = 0.004), meaning that, on average, about 40 % of the post-reconstruction lateral compartment displacement could be explained by the corresponding pre-reconstruction value. Both of these findings highlighted the importance of intra-operative quantification of rotatory knee laxity to identify correct indications for the surgery. CONCLUSIONS This study provided important implications for the future possibility of defining a quantifying tool able to assess rotatory knee laxity during ACL reconstruction. This could allow detection of additional injuries to secondary restraints by easily performing rotatory knee laxity tests, which in turn could reduce post-surgical recurrence of knee instability.
Collapse
|
45
|
Shaerf DA, Pastides PS, Sarraf KM, Willis-Owen CA. Anterior cruciate ligament reconstruction best practice: A review of graft choice. World J Orthop 2014; 5:23-29. [PMID: 24649411 PMCID: PMC3952691 DOI: 10.5312/wjo.v5.i1.23] [Citation(s) in RCA: 81] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/17/2013] [Revised: 09/05/2013] [Accepted: 10/20/2013] [Indexed: 02/06/2023] Open
Abstract
There is much literature about differing grafts used in anterior cruciate ligament (ACL) reconstruction. Much of this is of poor quality and of a low evidence base. We review and summarise the literature looking at the four main classes of grafts used in ACL reconstruction; bone-patella tendon-bone, hamstrings, allograft and synthetic grafts. Each graft has the evidence for its use reviewed and then compared, where possible, to the others. We conclude that although there is no clear “best” graft, there are clear differences between the differing graft choices. Surgeon’s need to be aware of the evidence behind these differences, in order to have appropriate discussions with their patients, so as to come to an informed choice of graft type to best suit each individual patient and their requirements.
Collapse
|
46
|
Stevanović V, Blagojević Z, Petković A, Glišić M, Sopta J, Nikolić V, Milisavljević M. Semitendinosus tendon regeneration after anterior cruciate ligament reconstruction: can we use it twice? INTERNATIONAL ORTHOPAEDICS 2013; 37:2475-81. [PMID: 23982635 DOI: 10.1007/s00264-013-2034-y] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/24/2013] [Accepted: 07/14/2013] [Indexed: 02/08/2023]
Abstract
PURPOSE It has been demonstrated that the semitendinosus tendon can regenerate after being harvested in its whole length and thickness for anterior cruciate ligament (ACL) reconstruction. Ultrasound studies and guided biopsies of the regenerated tendon have shown compatibility and resembling features of the normal tendon. The question is if this neo-tendon is biologically and functionally adequate for re-use? METHODS Two randomised groups of 150 volunteers were followed up for two years after harvesting the semitendinosus only (25) or the semitendinosus and gracilis tendons (25) in ACL reconstruction. The patients were followed up with clinical and ultrasound examinations, biopsies and histological tests. Surgical exploration was done in three patients for macroscopic verification. The injected arteries of four lower limbs were dissected and the tendon's arterial supplies were examined. RESULTS Seventy-two percent of the cases showed regeneration of the semitendinosus tendons. The neotendons were inserted mostly below the knee joint (83.3%) where they had fused with the gracilis tendon, and above the joint (60%) when the gracilis was harvested as well. The isokinetic strength of the hamstrings and quadriceps was not significantly diminished on the operated side. A macroscopic and histological analysis of the regenerated tendons demonstrates close resemblance to normal anatomy, with focal areas of fibrosis. In one patient the regenerated tendon was used for medial patellofemoral ligament reconstruction. CONCLUSION The semitendinosus muscle can recover and the tendon has great potential to regenerate after harvesting for ACL reconstruction. Our data suggest that the regenerated tendons could be used for iterative ligament reconstruction.
Collapse
Affiliation(s)
- Vladan Stevanović
- Institute for Orthopaedic Surgery "Banjica", Faculty of Medicine, University of Belgrade, Mihajla Avramovića 28, 11000, Belgrade, Serbia,
| | | | | | | | | | | | | |
Collapse
|
47
|
Two-stage procedure in anterior cruciate ligament revision surgery: a five-year follow-up prospective study. INTERNATIONAL ORTHOPAEDICS 2013; 37:1369-74. [PMID: 23624910 DOI: 10.1007/s00264-013-1886-5] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/18/2013] [Accepted: 03/25/2013] [Indexed: 01/22/2023]
Abstract
PURPOSE The purpose of this study was to show that this two-stage procedure for ACL (anterior cruciate ligament) revision surgery could be straight-forward and provide satisfactory clinical and functional outcomes. MATERIALS This is a five-year prospective analysis of clinical and functional data on 30 patients (19 men and 11 women; average age 29.1 ± 5.4) who underwent a two-stage ACL revision procedure after traumatic re-rupture of the ACL. Diagnosis was on Lachman and pivot-shift tests, arthrometer 30-lb KT-1000 side-to-side findings, and on MRI and arthroscopic assessments. RESULTS Postoperative IKDC and Lysholm scores were significantly improved compared to baseline values (P < 0.001). At the last follow up, 20 of 30 patients (66.7%) had returned to preoperative sport activity level (nine elite athletes, 11 county level), seven had changed to lower sport levels, and three had given up any sport activity. At the same appointment, 11 patients had degenerative changes. All these patients reported significantly lower Lysholm scores compared to patients without any degenerative change (p < 0.001). CONCLUSIONS In ACL revision surgery, when the first femoral tunnel has been correctly placed, this procedure allows safe filling of large bony defects, with no donor site comorbidities. It provides comfortable clinical, functional and imaging outcomes.
Collapse
|
48
|
van Kampen A. The knee joint in sports medicine. INTERNATIONAL ORTHOPAEDICS 2013; 37:177-9. [PMID: 23307019 DOI: 10.1007/s00264-013-1774-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/02/2013] [Accepted: 01/02/2013] [Indexed: 01/12/2023]
|