Pu J, Zhang Y, Zhang X, Yuan X, Yang S, Zhang G, Cui W, Tan Q, Jin Z. Fretting corrosion behavior of Ti6Al4V alloy against zirconia-toughened alumina ceramic in simulated body fluid. J Mech Behav Biomed Mater 2023; 142:105860. [PMID: 37127011 DOI: 10.1016/j.jmbbm.2023.105860] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2023] [Revised: 04/13/2023] [Accepted: 04/16/2023] [Indexed: 05/03/2023]
Abstract
The fretting corrosion at the head-neck interface of artificial hip joints is an important reason for the failure of prostheses. The Ti6Al4V alloy-zirconia-toughened alumina (ZTA) ceramic combination has been widely used to make the head and neck of artificial hip joints. In this study, its fretting corrosion behavior in simulated body fluid was studied by electrochemical monitoring, surface morphology characterization, and chemical composition analysis. A running condition fretting map (RCFM) of load and displacement was established, including three regimes, namely partial slip regime (PSR), mixed fretting regime (MFR), and gross slip regime (GSR). The friction dissipation energy increased gradually from the PSR to MFR and GSR. In the PSR, the damage mechanisms were slight abrasive wear and tribocorrosion at the edge of contact area, as well as extremely slight adhesive wear at the center. In the MFR, the damage mechanisms were mainly adhesive wear, abrasive wear, and corrosive wear. In the GSR, the damage mechanism was serious abrasive wear, fatigue wear, and corrosive wear combined with slight adhesive wear. Finally, an ion-concentration map was created, displaying the material-loss transition of different displacements and loads. The material loss increased with the increased displacement, and increased first and then decreased with the increased load.
Collapse
Affiliation(s)
- Jian Pu
- School of Mechanical Engineering, Southwest Jiaotong University, Sichuan, Chengdu, 610031, China
| | - Yali Zhang
- School of Mechanical Engineering, Southwest Jiaotong University, Sichuan, Chengdu, 610031, China.
| | - Xiaogang Zhang
- School of Mechanical Engineering, Southwest Jiaotong University, Sichuan, Chengdu, 610031, China
| | - Xinlu Yuan
- School of Mechanical Engineering, Chengdu University, Sichuan, Chengdu, 610106, China
| | - Shu Yang
- School of Mechanical Engineering, Southwest Jiaotong University, Sichuan, Chengdu, 610031, China
| | - Guoxian Zhang
- School of Mechanical Engineering, Southwest Jiaotong University, Sichuan, Chengdu, 610031, China
| | - Wen Cui
- Beijing AKEC Medical Co., Ltd., Beijing, 102200, China; School of Materials Science and Engineering, Peking University, Beijing, 100871, China
| | - Qin Tan
- School of Mechanical Engineering, Southwest Jiaotong University, Sichuan, Chengdu, 610031, China
| | - Zhongmin Jin
- School of Mechanical Engineering, Southwest Jiaotong University, Sichuan, Chengdu, 610031, China; School of Mechanical Engineering, University of Leeds, Leeds, LS2 9JT, UK
| |
Collapse
|
2
|
Lass R, Bechler U, Springer B, Rueckl K, Hanreich C, Boettner F. Midterm results of the Birmingham hip resurfacing: a single-surgeon series. Arch Orthop Trauma Surg 2023; 143:1041-1048. [PMID: 35076766 DOI: 10.1007/s00402-021-04305-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/21/2021] [Accepted: 12/04/2021] [Indexed: 11/26/2022]
Abstract
INTRODUCTION Birmingham hip resurfacing (BHR) is readily used as alternative to total hip replacement in younger patients. The current study aims to compare outcomes in terms of adverse local tissue reactions (ALTR), elevated metal ion levels and survival rates between low-risk (femoral component size ≥ 48 mm) and high-risk (femoral component size < 48 mm) BHR patients at a minimum 5-year follow-up (FU). MATERIALS AND METHODS We report the minimum 5-year, single surgeon outcome results of 183 BHRs, performed between 2007 and 2012. 154 patients, 18 women (20 hips) and 136 men (163 hips) were included in the study. Patients were grouped in 149 low-risk cases (femoral component size ≥ 48 mm) and in 34 high-risk cases (18 female/12 male) patients with a femoral head size < 48 mm). RESULTS At a minimum of 5-years FU time, 91% of the patients were available for FU. The overall survival rate was 91.8%. There were five revisions (survival rate 96.6%) in the low-risk group and ten revisions (survival rate 70.6%) in the high-risk group. In the low-risk group, six patients (6.5%) showed elevated metal ion levels (> 7 μg/l), compared to five patients (20.8%) in the high risk-group (p = 0.03). CONCLUSION Including the surgeon's initial learning curve, the BHR shows very good mid-term survival rates in the low-risk group but should, as previously demonstrated, not be considered for patients with less than 48 mm femoral head size. LEVEL OF EVIDENCE Level III: retrospective cohort study.
Collapse
Affiliation(s)
- Richard Lass
- Hospital for Special Surgery, Adult Reconstruction and Joint Replacement, 535 East 70th Street, New York, NY, 10021, USA
- Department of Orthopedics and Traumatology, Vienna General Hospital, Medical University of Vienna, Waehringer Guertel 18-20, 1090, Vienna, Austria
| | - Ulrich Bechler
- Hospital for Special Surgery, Adult Reconstruction and Joint Replacement, 535 East 70th Street, New York, NY, 10021, USA
- Department of Orthopedics, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Bernhard Springer
- Hospital for Special Surgery, Adult Reconstruction and Joint Replacement, 535 East 70th Street, New York, NY, 10021, USA
- Department of Orthopedics and Traumatology, Vienna General Hospital, Medical University of Vienna, Waehringer Guertel 18-20, 1090, Vienna, Austria
| | - Kilian Rueckl
- Hospital for Special Surgery, Adult Reconstruction and Joint Replacement, 535 East 70th Street, New York, NY, 10021, USA
- Orthopedic Clinic König-Ludwig-Haus, University of Wuerzburg, Würzburg, Germany
| | - Carola Hanreich
- Hospital for Special Surgery, Adult Reconstruction and Joint Replacement, 535 East 70th Street, New York, NY, 10021, USA
| | - Friedrich Boettner
- Hospital for Special Surgery, Adult Reconstruction and Joint Replacement, 535 East 70th Street, New York, NY, 10021, USA.
| |
Collapse
|
3
|
Nandra RS, Ahmed U, Berryman F, Brash L, Dunlop DJ, Matharu GS. How much does a Medical and Healthcare Products Regulatory Agency medical device alert for metal-on-metal hip arthroplasty patients really cost? Hip Int 2022; 32:493-500. [PMID: 33445979 PMCID: PMC9203671 DOI: 10.1177/1120700020983297] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND Many worldwide regulatory authorities recommend regular surveillance of metal-on-metal hip arthroplasty patients given high failure rates. However, concerns have been raised about whether such regular surveillance, which includes asymptomatic patients, is evidence-based and cost-effective. We determined: (1) the cost of implementing the 2015 MHRA surveillance in "at-risk" Birmingham Hip Resurfacing (BHR) patients; and (2) how many asymptomatic hips with adverse reactions to metal debris (ARMD) would have been missed without patient recall. METHODS All BHR patients eligible for the 2015 MHRA recall (all females, and males with head sizes ⩽46 mm, regardless of symptoms) at one centre were invited for review (hips = 707; patients = 593). All patients were investigated (Oxford Hip Score, radiographs, blood metal ions, and targeted cross-sectional imaging) and managed accordingly. Surveillance costs were calculated using finance department data. RESULTS The surveillance cost £105,921.79 (range £147.76-£257.50/patient). Radiographs (£39,598) and nurse practitioner time/assistance (£23,618) accounted for 60% of overall costs. 31 hips had ARMD on imaging (12 revised; 19 under surveillance). All revisions were symptomatic. 7 hips with ARMD under surveillance were asymptomatic and remain under regular review. The number needed to treat to avoid missing one asymptomatic ARMD case was 101 patients, representing a cost of £18,041 to avoid one asymptomatic case. CONCLUSIONS Implementing MHRA surveillance for "at-risk" BHR patients was extremely costly. The risk of asymptomatic ARMD was low with the BHR (1%), suggesting recommended follow-up in asymptomatic patients is not cost efficient. This raises concerns about the increasingly intensive surveillance recommended in the 2017 MHRA guidance for metal-on-metal hip patients.
Collapse
Affiliation(s)
| | - Usman Ahmed
- The Royal Orthopaedic Hospital, Birmingham, UK
| | | | | | | | - Gulraj S Matharu
- The Royal Orthopaedic Hospital, Birmingham, UK,Musculoskeletal Research Unit, Translational Health Sciences, Bristol Medical School, Southmead Hospital, Bristol, UK,Gulraj S Matharu, Musculoskeletal Research Unit, Translational Health Sciences, Bristol Medical School, 1st Floor Learning & Research Building, Southmead Hospital, Bristol, BS10 5NB, UK.
| |
Collapse
|
4
|
Bitar C, Moberg I, Krupic F, Wretenberg P, Otten V, Crnalic S. 11-Year outcomes in patients with metal-on-metal ASR hip arthroplasty. J Orthop 2022; 32:98-103. [PMID: 35663448 PMCID: PMC9160402 DOI: 10.1016/j.jor.2022.05.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/10/2022] [Revised: 04/25/2022] [Accepted: 05/23/2022] [Indexed: 11/23/2022] Open
Abstract
Background We analysed the long-term revision rate, clinical outcomes and metal ion concentrations in blood over time in patients who had undergone metal-on-metal Articular Surface Replacement (ASR) hip arthroplasty. Methods A total of 38 patients (43 hips) were included: 24 patients (28 hips) underwent large-head total hip arthroplasty (XL THA), and 14 patients (15 hips) underwent hip resurfacing arthroplasty (HRA). The median follow-up time was 11 (range 7-12) years. Results None of 15 HRA implants were revised. Nine of 28 XL THA implants (32%) in 8 patients were revised. The Co ion levels significantly increased in the XL THA group (p=0.009) over a median time period of 84 (25-97) months. Conclusion The levels of Co ions in blood were higher in the patients who had undergone XL THA and increased significantly over time.
Collapse
Affiliation(s)
- Christian Bitar
- Department of Clinical Science, Intervention and Technology, Karolinska Institute, Stockholm, Sweden
- Department of Orthopaedics, Karolinska University Hospital, Stockholm, Sweden
| | - Ivan Moberg
- Department of Surgical and Perioperative Sciences (Orthopaedics), Umeå University, Umeå, Sweden
| | - Ferid Krupic
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Per Wretenberg
- Department of Clinical Science, Intervention and Technology, Karolinska Institute, Stockholm, Sweden
- Department of Orthopaedics, School of Medical Sciences, Örebro University and Örebro University Hospital, Örebro, Sweden
| | - Volker Otten
- Department of Surgical and Perioperative Sciences (Orthopaedics), Umeå University, Umeå, Sweden
| | - Sead Crnalic
- Department of Surgical and Perioperative Sciences (Orthopaedics), Umeå University, Umeå, Sweden
| |
Collapse
|
5
|
PIETILÄINEN S, LINNOVAARA A, VENÄLÄINEN MS, MÄNTYMÄKI H, LAAKSONEN I, LANKINEN P, MÄKELÄ KT. Median 10-year whole blood metal ion levels and clinical outcome of ReCap-M2a-Magnum metal-on-metal total hip arthroplasty. Acta Orthop 2022; 93:444-450. [PMID: 35438184 PMCID: PMC9017114 DOI: 10.2340/17453674.2022.2510] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/25/2022] [Indexed: 01/31/2023] Open
Abstract
BACKGROUND AND PURPOSE We have previously reported that the whole blood (WB) chromium (Cr) and cobalt (Co) ion levels decrease in the short term after ReCap-M2a-Magnum large-diameter head (LDH) metal-on-metal (MoM) total hip arthroplasty (THA). This study reports long-term metal ion levels and clinical outcomes after ReCap-Magnum THA. PATIENTS AND METHODS ReCap-M2a-Magnum LDH THA was used in 1,450 patients in our hospital district from 2005 to 2012. Median follow-up time was 10 years. 991 patients had 2 or more metal ion measurements. The median measurement interval was 4 years. Individual metal ion change was assessed using logarithmic metal ion values in a random coefficient model. Kaplan-Meier survival estimates were calculated for revision surgery for any reason for revision, and separately for metal-related adverse events (metal ions above safe upper limit [SUL], revision due to ARMD, or pseudotumor). RESULTS Geometric mean of Cr decreased from 1.8 ppb (geometric standard deviation [GSD] 1.8) to 1.0 ppb (GSD 2.8, p < 0.001). The Co levels decreased from 1.7 ppb (GSD 2.4) to 1.4 ppb (GSD 2.8, p < 0.001). The hip-specific survival was 85% for revision due to any reason at 14 years and the hip-specific survival for any metal-related adverse event was 69% at 14 years. INTERPRETATION WB Cr and Co levels continued to decrease in the long-term follow-up of ReCap-M2a-Magnum THA patients. The amount of metal-related adverse events was rather high, but revision surgery was seldom required. We suggest that after 10 years from the implantation a 5-year measurement interval may be sufficient for asymptomatic ReCap-M2a-Magnum patients.
Collapse
Affiliation(s)
- Sakari PIETILÄINEN
- Department of Orthopaedics and Traumatology, Turku University Hospital,Department of Orthopaedics and Traumatology, Vaasa Central Hospital
| | - Axel LINNOVAARA
- Department of Orthopaedics and Traumatology, Vaasa Central Hospital
| | - Mikko S VENÄLÄINEN
- Turku Bioscience Centre, University of Turku and Åbo Akademi University,Turku University Hospital, Division of Medical Imaging, Department of Medical Physics, Turku
| | - Heikki MÄNTYMÄKI
- Department of Orthopaedics, Tampere University Hospital, Tampere
| | - Inari LAAKSONEN
- Department of Orthopaedics and Traumatology, Turku University Hospital,University of Turku
| | - Petteri LANKINEN
- Department of Orthopaedics and Traumatology, Turku University Hospital,University of Turku,Satasairaala Central Hospital, Satakunta Hospital District, Pori, Finland
| | - Keijo T MÄKELÄ
- Department of Orthopaedics and Traumatology, Turku University Hospital,University of Turku
| |
Collapse
|
6
|
Pietiläinen S, Lindström M, Laaksonen I, Venäläinen MS, Lankinen P, Mäkelä KT. Long-term blood metal ion levels and clinical outcome after Birmingham hip arthroplasty. Scand J Surg 2022; 111:14574969211066197. [PMID: 35168442 DOI: 10.1177/14574969211066197] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND AND OBJECTIVE Our aim was to assess long-term metal ion level changes and clinical outcome in patients with a Birmingham hip arthroplasty. METHODS For the purpose of this study, we identified all BHR hip resurfacing arthroplasty (HRA) and total hip arthroplasty (THA) operations performed in Turku University Hospital. A random coefficient model was used to compare the change between the first and last metal ion measurement. A Kaplan-Meier estimator was used to assess the survivorship of the BHR HRA and BHR THA with metal related adverse events (pseudotumor, elevated metal ions above the safe upper limit, revision due to metallosis), or revision due to any reason as endpoints with 95% confidence intervals (CIs). RESULTS BHR HRA was used in 274 hips (233 patients). In addition, we identified 38 BHR-Synergy THAs (38 patients). Operations were performed between 2003 and 2010. Median follow-up time was 14 years for BHR HRA (range: 0.6-17) and 11 years for BHR THA (range: 4.7-13). In the BHR HRA group, geometric means of Cr and Co levels decreased from 2.1 to 1.6 ppb and 2.4 to 1.5 ppb, respectively, during a 3.0-year measurement interval. Metal ion levels in the BHR THA group did not show notable increase. The survivorship of BHR HRA was 66% in 16 years and 34% for BHR THA at 12 years for any metal-related adverse event. CONCLUSIONS Patients with a Birmingham hip device do not seem to benefit from frequent repeated metal ion measurements. The amount of patients with metal-related adverse events was relatively high, but many of them did not require surgery.
Collapse
Affiliation(s)
- Sakari Pietiläinen
- Department of Orthopaedics and Traumatology Turku University Hospital, Luolavuorentie 2, 20701 and University of Turku, Turku, Finland
| | | | - Inari Laaksonen
- Department of Orthopaedics and Traumatology, Turku University Hospital and University of Turku, Turku, Finland
| | - Mikko S Venäläinen
- Turku Bioscience Centre, University of Turku and Åbo Akademi University and Department of Medical Physics, Division of Medical Imaging, Turku University Hospital, Turku, Finland
| | - Petteri Lankinen
- Department of Orthopaedics and Traumatology, Turku University Hospital and University of Turku, Turku, Finland
| | - Keijo T Mäkelä
- Department of Orthopaedics and Traumatology, Turku University Hospital and University of Turku, Turku, Finland
| |
Collapse
|
7
|
Agarwala S, Vijayvargiya M. Predictive factors affecting long-term survivorship of ASR metal-on-metal total hip arthroplasty. SICOT J 2021; 7:51. [PMID: 34668856 PMCID: PMC8527991 DOI: 10.1051/sicotj/2021040] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/08/2021] [Accepted: 07/14/2021] [Indexed: 12/30/2022] Open
Abstract
INTRODUCTION We present the outcome of 154 ASR (Articular Surface Replacement) hips performed at the P.D Hinduja Hospital and Medical Research Centre in terms of revision rate, metal ion levels, and factors affecting survivorship. Further, determined the importance of serial metal ion estimation over single value with poorly functioning arthroplasties. METHODS A retrospective study of 154 ASR arthroplasties (136 patients) performed from April 2005 till March 2010 was conducted. Ninety-seven patients were available for final analysis. All patients were assessed for symptoms, radiographs, blood metal (chromium and cobalt), metal artefact reduction sequence (MARS), magnetic resonance imaging (MRI), and computerized tomography (CT). RESULTS Female gender, smaller femoral head, patients with a rising level of metal ion levels were more likely to have revision surgery. However, abnormal acetabular inclination/anteversion was not associated with the occurrence of raised metal ion levels, ARMD (adverse reaction to metal debris) or revision surgery. Patients with raised metal ion levels were more likely to have periprosthetic lucency, ARMD, and revision surgery. Median metal levels increased initially for the first three years. Still, patients who required revision surgery continued to have a metal ion rise until the point when revision surgery was performed. In contrast, patients who had a fall in metal ion levels did not require revision. CONCLUSION A single metal ion value is less predictive of failing arthroplasties; instead, a rising trend of metal ion levels can better delineate arthroplasties which will require revision. ASR hips whose blood ion levels fell after an initial rise and showed a declining trend did well.
Collapse
Affiliation(s)
- Sanjay Agarwala
- Chief of Surgery and Director Professional Services, P.D Hinduja Hospital and Medical Research Centre, 400016 Mumbai, India
| | - Mayank Vijayvargiya
- Junior Consultant, Department of Orthopedics, P.D Hinduja Hospital and Medical Research Centre, 400016 Mumbai, India
| |
Collapse
|
8
|
Honkasaari N, Lainiala O, Laine O, Reito A, Eskelinen A. No association between blood count levels and whole-blood cobalt and chromium levels in 1,900 patients with metal-on-metal hip arthroplasty. Acta Orthop 2020; 91:711-716. [PMID: 33003969 PMCID: PMC8023953 DOI: 10.1080/17453674.2020.1827191] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - The accelerated wear of poorly functioning metal-on-metal (MoM) hip implants may cause elevated whole-blood cobalt (Co) and chromium (Cr) levels. Hematological and endocrinological changes have been described as the most sensitive adverse effects due to Co exposure. We studied whether there is an association between whole-blood Co/Cr levels and leukocyte, hemoglobin, or platelet levels. Patients and methods - We analyzed whole-blood Co and Cr values and complete blood counts (including leukocytes, hemoglobin, platelets) from 1,900 patients with MoM hips. The mean age at the time of whole-blood metal ion measurements was 67 years (SD 10). The mean time from primary surgery to whole-blood metal ion measurement was 8.2 years (SD 3.0). The mean interval between postoperative blood counts and metal ion measurements was 0.2 months (SD 2.7). Results - The median Co value was 1.9 µg/L (0.2-225), Cr 1.6 µg/L (0.2-125), mean leukocyte count 6.7 × 109/L (SD 1.9), hemoglobin value 143 g/L (SD 13), and platelet count 277 × 109/L (SD 70). We did not observe clinically significant correlations between whole-blood Co/Cr and leukocyte, hemoglobin, or platelet counts. Interpretation - Elevated whole-blood Co and Cr values are unlikely to explain abnormal blood counts in patients with MoM hips and the reason for possible abnormal blood counts should be sought elsewhere.
Collapse
Affiliation(s)
- Noora Honkasaari
- Coxa Hospital for Joint Replacement, Tampere,University of Tampere, Faculty of Medicine and Life Sciences, Tampere
| | - Olli Lainiala
- Coxa Hospital for Joint Replacement, Tampere,University of Tampere, Faculty of Medicine and Life Sciences, Tampere,Correspondence:
| | - Outi Laine
- University of Tampere, Faculty of Medicine and Life Sciences, Tampere,Tampere University Hospital, Department of Internal Medicine, Tampere, Finland
| | - Aleksi Reito
- Coxa Hospital for Joint Replacement, Tampere,University of Tampere, Faculty of Medicine and Life Sciences, Tampere
| | - Antti Eskelinen
- Coxa Hospital for Joint Replacement, Tampere,University of Tampere, Faculty of Medicine and Life Sciences, Tampere
| |
Collapse
|
9
|
Pozzuoli A, Berizzi A, Crimì A, Belluzzi E, Frigo AC, Conti GD, Nicolli A, Trevisan A, Biz C, Ruggieri P. Metal Ion Release, Clinical and Radiological Outcomes in Large Diameter Metal-on-Metal Total Hip Arthroplasty at Long-Term Follow-Up. Diagnostics (Basel) 2020; 10:diagnostics10110941. [PMID: 33198180 PMCID: PMC7698262 DOI: 10.3390/diagnostics10110941] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2020] [Revised: 11/10/2020] [Accepted: 11/11/2020] [Indexed: 02/08/2023] Open
Abstract
Total hip arthroplasty (THA) with metal-on-metal (MoM) bearings have shown problems of biocompatibility linked to metal ion release at the local level causing an adverse reaction to metal debris (ARMD) and at a systemic level. The aim of this study was to evaluate clinical and radiological outcomes, and metal ion concentrations in the blood and urine of patients who underwent THA with the LIMA Met-Met hip system. Patients with ceramic-on-ceramic (CoC) bearings were included as a control group. In this study, 68 patients were enrolled: 34 with MoM THAs and 34 with CoC THAs. Patients were evaluated clinically (Harris Hip Score, SF-36) and radiologically at a median of 7.4 years after surgery. Whole blood and urinary cobalt and chromium levels were also assessed. Both types of implants were comparable in terms of clinical and functional results. Ion levels were significantly higher in the MoM group compared with CoC group 7 years after surgery. No correlations were found between metal ion levels and patient demographics, functional and radiological outcomes, and prosthesis features. Patient monitoring is thus advised to establish if prosthesis revision is necessary, especially in the case of MoM THA.
Collapse
Affiliation(s)
- Assunta Pozzuoli
- Laboratory of Musculoskeletal Pathology and Oncology, Orthopaedic and Traumatologic Clinic, Department of Surgery, Oncology and Gastroenterology, University of Padova, Via Giustiniani 3, 35128 Padova, Italy
- Correspondence: (A.P.); (E.B.); Tel.: +39-0498213348 (A.P. & E.B.)
| | - Antonio Berizzi
- Orthopaedic and Traumatologic Clinic, Department of Surgery, Oncology and Gastroenterology, University of Padova, Via Giustiniani 3, 35128 Padova, Italy; (A.B.); (A.C.); (C.B.); (P.R.)
| | - Alberto Crimì
- Orthopaedic and Traumatologic Clinic, Department of Surgery, Oncology and Gastroenterology, University of Padova, Via Giustiniani 3, 35128 Padova, Italy; (A.B.); (A.C.); (C.B.); (P.R.)
| | - Elisa Belluzzi
- Laboratory of Musculoskeletal Pathology and Oncology, Orthopaedic and Traumatologic Clinic, Department of Surgery, Oncology and Gastroenterology, University of Padova, Via Giustiniani 3, 35128 Padova, Italy
- Correspondence: (A.P.); (E.B.); Tel.: +39-0498213348 (A.P. & E.B.)
| | - Anna Chiara Frigo
- Epidemiology and Public Health Unit, Department of Cardiac Thoracic Vascular Sciences and Public Health, Biostatistics, University of Padova, Via Loredan 18, 35131 Padova, Italy;
| | - Giorgio De Conti
- Department of Radiology, University Hospital of Padova, Via Giustiniani 2, 35128 Padova, Italy;
| | - Annamaria Nicolli
- Laboratory of Industrial Toxicology, Department of Cardiac Thoracic Vascular Sciences and Public Health, University of Padova, Via Giustiniani 2, 35128 Padova, Italy; (A.N.); (A.T.)
| | - Andrea Trevisan
- Laboratory of Industrial Toxicology, Department of Cardiac Thoracic Vascular Sciences and Public Health, University of Padova, Via Giustiniani 2, 35128 Padova, Italy; (A.N.); (A.T.)
| | - Carlo Biz
- Orthopaedic and Traumatologic Clinic, Department of Surgery, Oncology and Gastroenterology, University of Padova, Via Giustiniani 3, 35128 Padova, Italy; (A.B.); (A.C.); (C.B.); (P.R.)
| | - Pietro Ruggieri
- Orthopaedic and Traumatologic Clinic, Department of Surgery, Oncology and Gastroenterology, University of Padova, Via Giustiniani 3, 35128 Padova, Italy; (A.B.); (A.C.); (C.B.); (P.R.)
| |
Collapse
|
10
|
Pietiläinen S, Mäntymäki H, Vahlberg T, Reito A, Eskelinen A, Lankinen P, Mäkelä K. Repeated cobalt and chromium ion measurements in patients with bilateral large-diameter head metal-on-metal ReCap-M2A-Magnum total hip replacement. Acta Orthop 2020; 91:378-382. [PMID: 32285731 PMCID: PMC8023891 DOI: 10.1080/17453674.2020.1751940] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - Whole-blood (WB) chromium (Cr) and cobalt (Co) measurements are vital in the follow-up of metal-on-metal total hip replacement (MoM THR) patients. We examined whether there is a substantial change in repeated WB, Co, and Cr levels in patients with bilateral ReCap-M2A-Magnum THR. We also specified the number of patients exceeding the safe upper limit (SUL) of WB Co and Cr in the repeated measurement.Patients and methods - We identified 141 patients with bilateral ReCap-M2A-Magnum THR operated in our institution. 61 patients had repeated WB metal ion measurements with bilateral MoM implants still in situ in the second measurement. The mean time elapsing from the first measurement (initial measurement) to the second (control measurement) was 1.9 years (SD = 0.6, range 0.2-3.5). We used earlier established SUL levels for bilateral implants by Van Der Straeten et al. (2013).Results - The median (range) Co and Cr values decreased in the repeated measurement from 2.7 (0.6-25) to 2.1 (0.5-21) and 2.6 (0.8-14) to 2.1 (0.5-18) respectively. In 13% of the patients Co levels exceeded the SUL in the initial measurement and the proportion remained constant, at 13%, in the repeated measurement. In 5% of the patients, Cr levels were above SUL in the initial measurement and an equal 5% in the control measurement.Interpretation - Repeated WB metal ion levels did not increase in patients with bilateral ReCap-M2A-Magnum THR with a mean 1.9-year measurement interval. Long-term development of WB metal ion levels is still unclear in these patients.
Collapse
Affiliation(s)
- Sakari Pietiläinen
- Department of Orthopaedics and Traumatology, Turku University Hospital and University of Turku
| | - Heikki Mäntymäki
- Department of Orthopaedics, Tampere University Hospital and University of Turku
| | | | - Aleksi Reito
- Coxa Hospital for Joint Replacement, Tampere, Finland
| | | | - Petteri Lankinen
- Department of Orthopaedics and Traumatology, Turku University Hospital and University of Turku
| | - Keijo Mäkelä
- Department of Orthopaedics and Traumatology, Turku University Hospital and University of Turku
| |
Collapse
|
11
|
Mäntymäki H, Lankinen P, Vahlberg T, Reito A, Eskelinen A, Mäkelä K. Repeated cobalt and chromium ion measurements in patients with large-diameter head metal-on-metal ReCap-M2A-Magnum total hip replacement. Acta Orthop 2019; 90:243-248. [PMID: 30945585 PMCID: PMC6534222 DOI: 10.1080/17453674.2019.1595469] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - Whole blood (WB) cobalt (Co) and chromium (Cr) ion levels have a major role in the follow-up of metal-on-metal total hip replacement (MoM THR). We investigated, first, if there was a change in WB Co or Cr levels over repeated measurements in patients with ReCap-M2A-Magnum THR, and, second, determined how many patients had WB Co or Cr levels that exceeded the safe upper limits (SUL) in the repeated whole blood metal ion assessment. Patients and methods - A Recap-M2A-Magnum THR was used in 1,329 operations (1,188 patients) at our institution between 2005 and 2012. We identified all patients (n = 319) with unilateral ReCap-M2A-Magnum implants who had undergone at least 2 repeated metal ion measurements with the first blood sample taken mean 5.5 years (1.8-9.3) after surgery and the second taken mean 2 years (0.5-3) after the first. Results - The median WB Co and Cr ion levels decreased in repeated measurements from 1.40 (0.40-63) ppb to 1.10 (0.20-68) ppb and from 1.60 (0.60-13.0) ppb to 1.10 (0.30-19.0) ppb, respectively. 7% of the Co ion values exceeded SUL at the initial measurement, and 7% at the control measurement. The proportion of Cr ion values exceeding the safe upper limit (SUL) decreased during the measurement interval from 5% to 4%. Interpretation - Repeated metal ion measurements in unilateral ReCap-M2A-Magnum patients in a mean 2-year time interval did not show any increase. Long-term ion levels are, however, not yet known.
Collapse
Affiliation(s)
- Heikki Mäntymäki
- Department of Orthopaedics, Tampere University Hospital and University of Turku;; ,Correspondence:
| | - Petteri Lankinen
- Department of Orthopaedics and Traumatology, Turku University Hospital and University of Turku;;
| | | | - Aleksi Reito
- Coxa Hospital for Joint Replacement and University of Tampere, Finland
| | - Antti Eskelinen
- Coxa Hospital for Joint Replacement and University of Tampere, Finland
| | - Keijo Mäkelä
- Department of Orthopaedics and Traumatology, Turku University Hospital and University of Turku;;
| |
Collapse
|
12
|
Hernández-Vaquero D, García-Pascual M, Iglesias-Fernández S, Escandon-Rodríguez A. Metal-on-metal surface hip arthroplasties. Is annual monitoring of blood metal levels necessary? Rev Esp Cir Ortop Traumatol (Engl Ed) 2018. [DOI: 10.1016/j.recote.2018.03.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022] Open
|
13
|
Hjorth MH, Mechlenburg I, Soballe K, Jakobsen SS, Roemer L, Stilling M. Physical Activity Is Associated With the Level of Chromium but Not With Changes in Pseudotumor Size in Patients With Metal-on-Metal Hip Arthroplasty. J Arthroplasty 2018; 33:2932-2939. [PMID: 29807790 DOI: 10.1016/j.arth.2018.04.039] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/10/2018] [Revised: 04/17/2018] [Accepted: 04/23/2018] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Metal-on-metal (MoM) total hip arthroplasty (THA) and resurfacing hip arthroplasty (RHA) were previously considered an excellent option for young and physically active patients. However, the relationship between MoM THA/RHA patients' daily physical activity (PA), metal ion measurements of chromium and cobalt, and pseudotumor dynamic is insufficiently explored. METHODS One hundred eleven patients with 148 hip articulations, 77 MoM THA/RHA and 71 MoP THA, participated in a prospective cohort study, with 5 cross-sectional analyses during a 1-year follow-up. Baseline follow-up was at mean 7.1 (range: 0.2-21.5) years postoperative. At baseline and every 3 months thereafter, patients' daily PA was monitored during a 2-week period using a triaxial accelerometer, and next metal artifact reducing sequence magnetic resonance imaging scans, metal ion measurements of chromium and cobalt, and the Copenhagen Hip and Groin Outcome Score questionnaire were completed. RESULTS We found a statistically significant relationship between daily PA and metal ion measurements of chromium at all follow-ups in MoM THA/RHA patients (P ≤ .03) but not in MoP THA patients (P > .35). Patients' daily PA was not related to changes in pseudotumor size at any follow-up (P > .30). Ten of 26 (38%) pseudotumors in MoM THA/RHA and 8 of 29 (28%) pseudotumors in MoP THA changed classification according to the Anderson grading. No pseudotumors transformed in appearance or changed anatomical location. CONCLUSION The daily PA of MoM THA/RHA patients is associated with metal ion measurements of chromium but not with changes in pseudotumor size. This is new and important knowledge, which may be useful for hip surgeons in recommendation and monitoration of the consequences of PA in active patients with MoM THA/RHA.
Collapse
Affiliation(s)
- Mette H Hjorth
- Department of Orthopaedics, Aarhus University Hospital, Aarhus, Denmark; Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| | - Inger Mechlenburg
- Department of Orthopaedics, Aarhus University Hospital, Aarhus, Denmark; Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| | - Kjeld Soballe
- Department of Orthopaedics, Aarhus University Hospital, Aarhus, Denmark; Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| | - Stig S Jakobsen
- Department of Orthopaedics, Aarhus University Hospital, Aarhus, Denmark; Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| | - Lone Roemer
- Department of Radiology, Aarhus University Hospital, Aarhus, Denmark
| | - Maiken Stilling
- Department of Orthopaedics, Aarhus University Hospital, Aarhus, Denmark; Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| |
Collapse
|
14
|
Higher Prevalence of Mixed or Solid Pseudotumors in Metal-on-Polyethylene Total Hip Arthroplasty Compared With Metal-on-Metal Total Hip Arthroplasty and Resurfacing Hip Arthroplasty. J Arthroplasty 2018. [PMID: 29526334 DOI: 10.1016/j.arth.2018.02.011] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Pseudotumors are a common finding in metal-on-metal (MoM) total hip arthroplasty (THA) and resurfacing hip arthroplasty (RHA). However, information on pseudotumors in metal-on-polyethylene (MoP) THA is limited. METHODS One hundred eleven patients with 148 hip articulations-30 MoM THA, 47 MoM RHA, and 71 MoP THA-participated in a cross-sectional study at mean 7.1 (range: 0.2-21.5) years postoperatively. Patients were evaluated with metal artifact reducing sequence magnetic resonance imaging, measurements of metal ions, clinical scores of Harris Hip Score, Oxford Hip Score, the Copenhagen Hip and Groin Outcome Score, and conventional radiographs. RESULTS Pseudotumors were present in 13 of 30 (43%) MoM THA, 13 of 47 (28%) MoM RHA, and 29 of 71 (41%) MoP THA patients, which was a similar prevalence (P = .10). The prevalence of mixed or solid pseudotumors was significantly higher in patients with MoP THA (n = 10) compared to MoM THA (n = 3) and MoM THA (n = 0), (P = .01). Hips with a mixed or solid pseudotumor had significantly poorer scores of Harris Hip Score (P = .01) and OHS (P = .002) and higher metal ion levels of cobalt (P = .0009) compared to hips without a pseudotumor or with a cystic pseudotumor. CONCLUSION Pseudotumors have primarily been associated with MoM hip articulations, but we found a similar pseudotumor prevalence in MoP THA, which is the most common bearing worldwide. Mixed or solid pseudotumors were more often seen in MoP THA compared with MoM hip articulations, and patients with a mixed or solid pseudotumor had poorer clinical scores and higher metal ion levels than patients without a pseudotumor or with a cystic pseudotumor.
Collapse
|
15
|
Hernández-Vaquero D, García-Pascual M, Iglesias-Fernández S, Escandon-Rodríguez A. Metal-on-metal surface hip arthroplasties. Is annual monitoring of blood metal levels necessary? Rev Esp Cir Ortop Traumatol (Engl Ed) 2018; 62:436-441. [PMID: 29884514 DOI: 10.1016/j.recot.2018.03.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2017] [Revised: 02/19/2018] [Accepted: 03/13/2018] [Indexed: 11/27/2022] Open
Abstract
INTRODUCTION Blood cobalt (Co) and chromium (Cr) ion levels have been used as surveillance tools for adverse reaction to metal debris in metal-on-metal (MoM) hip arthroplasty. The aim of our study was to present serial 7-13 year blood Co and Cr levels in a cohort of MoM total hip arthroplasties in asymptomatic patients. MATERIAL AND METHODS A total of 52 MoM surface total hip arthroplasties were included in this study with data collected prospectively. Annual follow-up with blood Co and Cr measurements was performed. Revision surgery was necessary for 16 patients and therefore they dropped out of the study. The metal ion levels were analyzed separately in 31 asymptomatic patients. RESULTS High Cr or Co levels were not found continuously in any of the asymptomatic patients. The median Cr in blood was maintained between 1.3 and 5.4μg/L and that of Co between 0.5 and 1.2μg/L. After 7 years, there was no significant change in Co and Cr values. CONCLUSION In the medium term and in asymptomatic patients, the metallic blood levels remained unchanged; therefore, it does not seem appropriate to repeat these tests on a permanent basis in annual controls.
Collapse
Affiliation(s)
- D Hernández-Vaquero
- Departamento de Cirugía, Facultad de Medicina, Universidad de Oviedo, Oviedo, España; Servicio de Cirugía Ortopédica y Traumatología, Hospital Universitario San Agustín, Avilés, España.
| | - M García-Pascual
- Servicio de Cirugía Ortopédica y Traumatología, Hospital Universitario San Agustín, Avilés, España
| | - S Iglesias-Fernández
- Servicio de Cirugía Ortopédica y Traumatología, Hospital Universitario San Agustín, Avilés, España
| | - A Escandon-Rodríguez
- Servicio de Cirugía Ortopédica y Traumatología, Hospital Universitario San Agustín, Avilés, España
| |
Collapse
|
16
|
Lehtovirta L, Reito A, Parkkinen J, Peräniemi S, Vepsäläinen J, Eskelinen A. Association between periprosthetic tissue metal content, whole blood and synovial fluid metal ion levels and histopathological findings in patients with failed metal-on-metal hip replacement. PLoS One 2018; 13:e0197614. [PMID: 29768492 PMCID: PMC5955572 DOI: 10.1371/journal.pone.0197614] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2017] [Accepted: 05/04/2018] [Indexed: 02/08/2023] Open
Abstract
Adverse Reaction to Metal Debris (ARMD) is a major cause of implant failure leading to revision surgery in patients with metal-on-metal (MoM) hip arthroplasties. However, the pathogenesis and its association to implant wear are poorly understood and previous studies have yielded discrepant results. We sought to investigate the associations between histological findings, whole blood and synovial fluid metal ion concentrations and periprosthetic tissue metal concentrations in patients with MoM total hip replacements and hip resurfacings revised for ARMD. 107 hips in total were included in our study. Of these, 87 were total hip replacements and 20 were hip resurfacings, respectively. We found that whole blood, synovial fluid and periprosthetic tissue metal concentrations correlated poorly with histological findings. We suggest that the lack of a clear association between histological findings and wear measures in the present study as well as in previous studies is mostly influenced by variability in patient susceptibility. However, patients presenting with perivascular lymphocytic infiltration had lower chromium concentration in their periprosthetic tissues than patients with no perivascular lymphocytic infiltration. This may reflect the role of metal hypersensitivity in implant failure in these patients. Patients with total hip replacements evinced more necrosis and lymphocytic infiltration in their tissues than patients with hip resurfacings. This suggests that trunnion wear debris is more cytotoxic and/or immunogenic than bearing wear debris leading to higher failure rates seen in patients with total hip replacements.
Collapse
Affiliation(s)
- Lari Lehtovirta
- University of Tampere, Tampere, Finland
- Coxa Hospital for Joint Replacement, Tampere, Finland
- * E-mail:
| | - Aleksi Reito
- Coxa Hospital for Joint Replacement, Tampere, Finland
| | | | | | | | | |
Collapse
|
17
|
Markel DC, Bergum C, Flynn J, Jackson N, Bou-Akl T, Ren W. Relationship of Blood Metal Ion Levels and Leukocyte Profiles in Patients With Articular Surface Replacement Metal-on-Metal Hip Replacement. Orthopedics 2018; 41:e424-e431. [PMID: 29708567 DOI: 10.3928/01477447-20180409-02] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/30/2017] [Accepted: 01/22/2018] [Indexed: 02/03/2023]
Abstract
The purpose of this study was to compare blood leukocyte profiles and metal ion concentrations between hip resurfacing arthroplasty (articular surface replacement) patients with and without revision. A total of 25 articular surface replacement patients were recruited (10 with stable implants and 15 undergoing revision). Blood concentrations of chromium (Cr) and cobalt (Co) were measured. Flow cytometry was used to quantify the subpopulations of leukocytes, including CD14+ monocytes, CD16+ monocytes, CD3+ T-lymphocytes, CD19+ B-lymphocytes, CD4+ helper T-cells, and CD45+RA memory vs naïve T-cells. Patients undergoing revision had higher blood Co (mean, 10.85 µg/L) and Cr (mean, 3.19 µg/L) levels than patients with stable implants (mean Co, 3.06 µg/L; mean Cr, 1.07 µg/L) (P<.05). The number of CD4+ helper T-cells was higher in patients with stable implants (mean, 842±311 cells/µL) than in patients undergoing revision (mean, 591±208 cells/µL) (P<.05). There was a significant association between total metal ion levels (Co+Cr) and the number of CD14+ monocytes (P=.045) and inflammatory CD16+ monocytes (P=.046). The authors observed that the increase in blood metal ions was associated with an increase in CD16+ monocytes. They believe that continued analysis of blood leukocyte profiles may be helpful in defining differences among failed articular surface replacement, stable articular surface replacement, and failed metal-on-polyethylene implants. [Orthopedics. 2018; 41(3):e424-e431.].
Collapse
|
18
|
Uchihara Y, Grammatopoulos G, Munemoto M, Matharu G, Inagaki Y, Pandit H, Tanaka Y, Athanasou NA. Implant failure in bilateral metal-on-metal hip resurfacing arthroplasties: a clinical and pathological study. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2018; 29:28. [PMID: 29516273 PMCID: PMC5842269 DOI: 10.1007/s10856-018-6037-5] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/10/2017] [Accepted: 02/22/2018] [Indexed: 06/13/2023]
Abstract
Metal-on-metal hip resurfacing arthroplasties (MoMHRAs) have a high failure rate due to pseudotumour formation. It is not certain whether pseudotumours in bilateral MoMHRAs form on the basis of an adverse reaction to metal debris (ARMD) that is entirely due to a local innate and adaptive immune response to Cobalt-Chrome (Co-Cr) wear particles. To determine if there is a systemic component to ARMD in bilateral MoMHRAs, we examined the histology of ARMD in unilateral and bilateral MoMHRAs revised for pseudotumour and determined whether implant survival differed between these two groups. Periprosthetic tissue specimens from 119 hips revised for pseudotumour were examined. These were derived from 109 patients including 10 patients with bilateral MoMHRAs and 99 with sunilateral MoMHRAs including a cohort of 20 patients with bilateral MoMHRAs that had undergone only one MoMHRA revision for pseudotumour. The mean time to revision for pseudotumour of unilateral and bilateral MoMHRAs was determined. The histology of periprosthetic tissue was examined for evidence of the innate and adaptive immune response and scored semi-quantitatively. There was no significant difference in histological features of the innate / adaptive response between Group 1 bilateral pseudotumours and Group 2 and Group 3 unilateral pseudotumours. Histological features, including ALVAL scores, were similar in the periprosthetic tissues of right and left hips in Group 1 bilateral MoMHRAs. The mean time to first revision for pseudotumour of bilateral MoMHRAs (6.59 years) was not decreased compared with unilateral MoMHRAs (5.66 years) or bilateral MoMHRAs that had only one revision (7.05 years). Right and left hip pseudotumours in bilateral MoMHRAs exhibit similar histological features of the innate and adaptive immune response. Mean implant survival is not decreased in bilateral compared with unilateral MoMHRA cases. The findings suggest that pseudotumour formation is due more to a local than a systemic innate /adaptive immune response to components of metal wear.
Collapse
Affiliation(s)
- Yoshinubo Uchihara
- Department of Orthopaedic Surgery, Nara Medical University, Shijocho 840, Kashihara, Nara, 634-8522, Japan
| | - George Grammatopoulos
- Nuffield Department of Orthopaedics, Rheumatology and Surgery, Nuffield Orthopaedic Centre, University of Oxford, Headington, Oxford, OX3 7HE, UK.
| | - Mitsuru Munemoto
- Department of Orthopaedic Surgery, Nara Medical University, Shijocho 840, Kashihara, Nara, 634-8522, Japan
| | - Gulraj Matharu
- Nuffield Department of Orthopaedics, Rheumatology and Surgery, Nuffield Orthopaedic Centre, University of Oxford, Headington, Oxford, OX3 7HE, UK
| | - Yusuke Inagaki
- Department of Orthopaedic Surgery, Nara Medical University, Shijocho 840, Kashihara, Nara, 634-8522, Japan
| | - Hemant Pandit
- Nuffield Department of Orthopaedics, Rheumatology and Surgery, Nuffield Orthopaedic Centre, University of Oxford, Headington, Oxford, OX3 7HE, UK
| | - Yasuhito Tanaka
- Department of Orthopaedic Surgery, Nara Medical University, Shijocho 840, Kashihara, Nara, 634-8522, Japan
| | - Nick A Athanasou
- Nuffield Department of Orthopaedics, Rheumatology and Surgery, Nuffield Orthopaedic Centre, University of Oxford, Headington, Oxford, OX3 7HE, UK.
| |
Collapse
|
19
|
|
20
|
Matharu GS, Judge A, Eskelinen A, Murray DW, Pandit HG. What is appropriate surveillance for metal-on-metal hip arthroplasty patients? Acta Orthop 2018; 89:29-39. [PMID: 29105547 PMCID: PMC5810829 DOI: 10.1080/17453674.2017.1398011] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
The unexpected high revision rates of large-diameter (femoral head sizes of 36 mm or greater) metal-on-metal hip arthroplasties (MoMHAs) have led to worldwide regulatory authorities recommending regular surveillance, even for asymptomatic individuals. However, these recommendations are not evidence-based and are very costly. The rapidly evolving evidence base requires an update regarding the investigation and management of MoMHA patients. This article is the first of 2 (the second article in this series will consider the threshold for performing revision, and the outcomes following ARMD revision surgery: Matharu et al., Revision surgery of metal-on-metal hip arthroplasties for adverse reactions to metal debris: A clinical update. Acta Orthop 2018; in press), and considers the various investigative modalities used during surveillance, with specific focus on blood metal ion sampling and cross-sectional imaging. No single investigation can universally be used during MoMHA patient surveillance. Recent studies have now provided important information on interpreting blood metal ions (effective in identifying patients at low risk of problems), clarifying the roles of cross-sectional imaging (reserve combined ultrasound and MARS-MRI for complex cases), and providing parameters to safely exclude many asymptomatic patients from regular surveillance. This information will be useful when designing future surveillance protocols for MoMHA patients.
Collapse
Affiliation(s)
- Gulraj S Matharu
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences University of Oxford, Nuffield Orthopaedic Centre, Oxford, UK;,Correspondence:
| | - Andrew Judge
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences University of Oxford, Nuffield Orthopaedic Centre, Oxford, UK
| | | | - David W Murray
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences University of Oxford, Nuffield Orthopaedic Centre, Oxford, UK
| | - Hemant G Pandit
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences University of Oxford, Nuffield Orthopaedic Centre, Oxford, UK
| |
Collapse
|
21
|
Galea VP, Laaksonen I, Matuszak SJ, Connelly JW, Muratoglu O, Malchau H. Mid-term changes in blood metal ion levels after Articular Surface Replacement arthroplasty of the hip. Bone Joint J 2017; 99-B:33-40. [PMID: 28363892 DOI: 10.1302/0301-620x.99b4.bjj-2016-1250.r1] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/01/2016] [Accepted: 01/04/2017] [Indexed: 11/05/2022]
Abstract
AIMS Our first aim was to determine whether there are significant changes in the level of metal ions in the blood at mid-term follow-up, in patients with an Articular Surface Replacement (ASR) arthroplasty. Secondly, we sought to identify risk factors for any increases. PATIENTS AND METHODS The study involved 435 patients who underwent unilateral, metal-on-metal (MoM) hip resurfacing (HRA) or total hip arthroplasty (THA). These patients all had one measurement of the level of metal ions in the blood before seven years had passed post-operatively (early evaluation) and one after seven years had passed post-operatively (mid-term evaluation). Changes in ion levels were tested using a Wilcoxon signed-rank test. We identified subgroups at the highest risk of increase using a multivariable linear logistic regression model. RESULTS There were significant increases in the levels of metal ions for patients who underwent both MoM HRA (Chromium (Cr): 0.5 parts per billion (ppb); Cobalt (Co): 1.1 ppb) and MoM THA (Cr: 0.5 ppb; Co: 0.7 ppb). In a multivariable model considering MoM HRAs, the change in the levels of metal ions was influenced by female gender (Co: Odds Ratio (OR) 1.42; p = 0.002 and Cr: OR 1.08; p = 0.006). The change was found to be irrespective of the initial level for the MoM HRAs, whereas there was a negative relationship between the initial level and the change in the level for those with a MoM THA (Co: OR -0.43; p < 0.001 and Cr: OR -0.14; p = 0.033). CONCLUSION The levels of metal ions in the blood increase significantly over the period until mid-term follow-up in patients with both a MoM HRA and those with a MoM THA. We recommend that the levels of metal ions be measured most frequently for women with a MoM HRA. While those with a MoM THA appear to stabilise at a certain level, the accuracy of this trend is not yet clear. Vigilant follow-up is still recommended. Cite this article: Bone Joint J 2017;99-B(4 Supple B):33-40.
Collapse
Affiliation(s)
- V P Galea
- Massachusetts General Hospital, Harris Orthopaedic Laboratory, 55 Fruit St. GRJ 1231, Boston, MA 02114, USA
| | - I Laaksonen
- Harvard Medical School, 25 Shattuck St, Boston, MA 02115, USA
| | - S J Matuszak
- Massachusetts General Hospital, Harris Orthopaedic Laboratory, 55 Fruit St. GRJ 1231, Boston, MA 02114, USA
| | - J W Connelly
- Massachusetts General Hospital, Harris Orthopaedic Laboratory, 55 Fruit St. GRJ 1231, Boston, MA 02114, USA
| | - O Muratoglu
- Harvard Medical School, 25 Shattuck St, Boston, MA 02115, USA
| | - H Malchau
- Harvard Medical School, 25 Shattuck St, Boston, MA 02115, USA
| |
Collapse
|
22
|
The value of serial metal ion levels in following up patients with metal-on-metal hip arthroplasty. Hip Int 2017; 27:14-20. [PMID: 28106230 DOI: 10.5301/hipint.5000432] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 06/17/2016] [Indexed: 02/04/2023]
Abstract
BACKGROUND The sensitivity of cobalt (Co) and chromium (Cr) ion-levels in detecting poorly performing metal-on-metal hip implants is low. This study proposes that serial changes in ion-levels are a more accurate marker of arthroplasties at risk. METHODS Serial metal ion-levels and implant data of 285 patients with ASR resurfacing or replacement were studied. Patient and implant characteristics were analysed using univariate and multivariate analyses. RESULTS 111 (39%) had revision surgery. Time since index surgery (p<0.001), acetabular inclination (p<0.001), their interaction (p<0.001) and femoral head size (p = 0.01) were significant variables. Head size (≤51 mm) had lower Co and Cr levels (p = 0.01). Cr/Co showed marginal decrease over time in the unrevised group and no decrease prerevision. CONCLUSIONS Repeated measurement of ion-levels were higher in the revision group suggesting that serial measurements rather than absolute values may have a role to play in predicting implant failure.
Collapse
|
23
|
Nakano N, Volpin A, Bartlett J, Khanduja V. Management Guidelines for Metal-on-metal Hip Resurfacing Arthroplasty: A Strategy on Followup. Indian J Orthop 2017; 51:414-420. [PMID: 28790470 PMCID: PMC5525522 DOI: 10.4103/ortho.ijortho_230_17] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Despite the initial promise of metal-on-metal (MoM) implants as the ideal bearing surface for hip replacements and resurfacings, high short term failure rates due to an adverse reaction to metal debris (ARMD) have led to a dramatic reduction in the number of MoM implants used in the modern era. With over one million patients worldwide having undergone hip operations utilizing a MoM bearing surface, the long term outcomes for such patients remains unknown, and there is much debate as to the most effective management of these patients. Although several regulatory bodies have released guidelines on the management of patients with MoM hips, these recommendations remain open to interpretation, and the most effective management for these patients remains unclear. The aim of this review is to compare the current guidelines for managing patients with MoM hips and also to discuss established ARMD risk factors, evidence regarding the optimum management for patients with MoM hips, and the indications for revision surgery. Furthermore, although specialized laboratory tests and imaging can be used to facilitate clinical decision making, over-reliance on any single tool should be avoided in the decision making process, and surgeons should carefully consider all findings when determining the most appropriate course of action.
Collapse
Affiliation(s)
- Naoki Nakano
- Department of Trauma and Orthopaedics, Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge, CB2 0QQ, UK
| | - Andrea Volpin
- Department of Trauma and Orthopaedics, Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge, CB2 0QQ, UK
| | - Jonathan Bartlett
- Department of Trauma and Orthopaedics, Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge, CB2 0QQ, UK
| | - Vikas Khanduja
- Department of Trauma and Orthopaedics, Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge, CB2 0QQ, UK,Address for correspondence: Mr. Vikas Khanduja, Consultant Orthopaedic Surgeon and Elective Clinical Trials Research Lead, Department of Trauma and Orthopaedics, Cambridge University Hospitals NHS Foundation Trust, Box 37, Hills Road, Cambridge, CB2 0QQ, UK. E-mail:
| |
Collapse
|
24
|
Grammatopoulos G, Munemoto M, Pollalis A, Athanasou NA. Correlation of serum metal ion levels with pathological changes of ARMD in failed metal-on-metal-hip-resurfacing arthroplasties. Arch Orthop Trauma Surg 2017; 137:1129-1137. [PMID: 28660477 PMCID: PMC5511305 DOI: 10.1007/s00402-017-2723-x] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/05/2016] [Indexed: 01/25/2023]
Abstract
BACKGROUND Metal-on-metal-hip-resurfacing arthroplasties (MoMHRAs) have been associated with an increased failure rates due to an adverse-response-to-metal-debris (ARMD) associated with a spectrum of pathological features. Serum levels of cobalt (Co) and chromium (Cr) are used to assess MoMHRAs, with regard to ARMD, but it is not certain whether ion levels correlate with pathological changes in periprosthetic tissues. METHODS Serum Co and Cr levels were correlated with histological findings in 38 revised MoMHRAs (29 pseudotumour cases and 9 non-pseudotumour cases revised for pain). The extent of necrosis and macrophage infiltrate as well as the aseptic lymphocyte-dominated vasculitis-associated lesion (ALVAL) response was assessed semi-quantitatively; the prosthesis linear wear rate (PLWR) was also determined in ten cases. RESULTS Cr levels were elevated in 82% and Co levels elevated in 53% of cases; the PLWR correlated with Cr level (rho = 0.8, p = 0.006). Tissue necrosis and macrophage infiltration were noted in all, most of which also exhibited significant ALVAL. Although a discrete correlation was not seen between Co and/or Cr ion levels and the extent of necrosis, degree of macrophage infiltration, or ALVAL score, it was noted that cases with acceptable metal ions levels had high ALVAL score. CONCLUSION Histological features of both innate and adaptive immune response to metal wear are seen in periprosthetic tissues in cases with both elevated and non-elevated metal ion levels. MoMHRA failures with acceptable ion levels exhibited a pronounced ALVAL response. Although metal ion levels are elevated in most cases of MoMHRA failure due to ARMD, the finding of a normal metal ion level does not exclude this diagnosis.
Collapse
Affiliation(s)
- George Grammatopoulos
- Nuffield Orthopaedic Centre, Windmill Road, Headington, Oxford, OX3 7LD UK ,Nuffield Department Orthopaedics Rheumatology and Musculoskeletal Sciences (NDORMS), University of Oxford, Windmill Road, Oxford, UK
| | - Mitsuru Munemoto
- Nuffield Department Orthopaedics Rheumatology and Musculoskeletal Sciences (NDORMS), University of Oxford, Windmill Road, Oxford, UK ,Department of Orthopaedic Surgery, Nara Medical University, Kashihara-City, Nara 634-8522 Japan
| | | | - Nicholas A. Athanasou
- Nuffield Orthopaedic Centre, Windmill Road, Headington, Oxford, OX3 7LD UK ,Nuffield Department Orthopaedics Rheumatology and Musculoskeletal Sciences (NDORMS), University of Oxford, Windmill Road, Oxford, UK
| |
Collapse
|
25
|
Outcomes of the Recalled Articular Surface Replacement Metal-on-Metal Hip Implant System: A Systematic Review. J Arthroplasty 2017; 32:341-346. [PMID: 27546469 DOI: 10.1016/j.arth.2016.06.060] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/02/2016] [Revised: 06/05/2016] [Accepted: 06/27/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The aim of this review was to synthesize the main findings of clinical studies that have evaluated outcomes of the articular surface replacement (ASR) Hip System. METHODS We performed a systematic literature search to identify all articles published between January 2008 and June 2015 that included ASR hip resurfacing arthroplasty (ASR HRA) or ASR total hip arthroplasty (ASR XL THA) outcomes according to the PRISMA statement. RESULTS A total of 56 studies were assessed. The prevalence of adverse local tissue reactions (ALTRs) and revision rates were found to be high. ALTR prevalence varied from 12.5% to 69% (mean, 33.5%). Mean revision rate for any reason at 4-year to 7-year follow-up was 13.8% (range, 5.6%-31%) for ASR HRA and 14.5% (range, 0%-37%) for ASR XL THA. Femoral head size <53 mm was found to correlate with higher blood metal ion levels. Femoral head size >44 mm was not associated with higher ALTR prevalence or revision rates in ASR XL THA. High blood metal ion levels (>7 μg/L Co, >7 μg/L Cr) were associated with higher failure rates and bearing-related complications. The role of cup positioning was found to be controversial. CONCLUSION ALTR prevalence and failure rates were high. High blood metal ion levels were a risk factor for ALTR and failure. Surprisingly, the role of cup positioning and large femoral head size in ASR XL THA were controversial. These findings should be considered in the clinical follow-up and risk stratification of patients with the ASR Hip System.
Collapse
|
26
|
Liow MHL, Kwon YM. Metal-on-metal total hip arthroplasty: risk factors for pseudotumours and clinical systematic evaluation. INTERNATIONAL ORTHOPAEDICS 2016; 41:885-892. [PMID: 27761629 DOI: 10.1007/s00264-016-3305-1] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/14/2016] [Accepted: 09/25/2016] [Indexed: 12/12/2022]
Abstract
The potential advantages of contemporary MoM THA implants include less volumetric wear with subsequent reduction of polyethylene wear-induced osteolysis and greater component stability with use of large-diameter femoral heads. However, there have been concerns regarding significantly elevated revision rates in MoM THA due to MoM-related complications such as adverse local tissue reaction (pseudotumour) formation. The increased failure rate in MoM hip arthroplasty is associated with the generation of biologically active, nanometer sized metal particles from the MoM bearing surfaces and taper junctions, which result in the development of a localized, adverse periprosthetic soft tissue response. The focus of this article is to provide an update on (1) implant, surgical and patient factors associated with adverse local tissue reactions (pseudotumours) and (2) the clinical systematic evaluation and management of patients with MoM hip arthroplasty based on the currently available evidence. There should be a low threshold to conduct a systematic clinical evaluation of patients with MoM hip arthroplasty as early recognition and diagnosis will allow the initiation of prompt and appropriate treatment. As a symptomatic MoM total hip arthroplasty may have intrinsic and extrinsic causes, patients should be evaluated systematically, utilizing risk stratification algorithms. Although specialized laboratory tests such as metal ion levels and cross sectional imaging modalities such as MARS MRI can be used to facilitate clinical decision making, over-reliance on any single investigative tool in the clinical decision-making process should be avoided. Further research is required to obtain a better understanding of implant and patient risk factors associated with tribocorrosion in MoM total hip arthroplasty.
Collapse
Affiliation(s)
- Ming Han Lincoln Liow
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Young-Min Kwon
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA.
| |
Collapse
|
27
|
Paukkeri EL, Korhonen R, Hämäläinen M, Pesu M, Eskelinen A, Moilanen T, Moilanen E. The Inflammatory Phenotype in Failed Metal-On-Metal Hip Arthroplasty Correlates with Blood Metal Concentrations. PLoS One 2016; 11:e0155121. [PMID: 27227536 PMCID: PMC4882013 DOI: 10.1371/journal.pone.0155121] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2014] [Accepted: 04/25/2016] [Indexed: 12/12/2022] Open
Abstract
INTRODUCTION Hip arthroplasty is the standard treatment of a painful hip destruction. The use of modern metal-on-metal (MOM) bearing surfaces gained popularity in total hip arthroplasties during the last decade. Recently, worrisome failures due to adverse reaction to metal debris (ARMD), including pseudotumor response, have been widely reported. However, the pathogenesis of this reaction remains poorly understood. The aim of the present study was to investigate the ARMD response by flow cytometry approach. METHODS Sixteen patients with a failed Articular Surface Replacement (ASR) hip prosthesis were included in the study. Samples of pseudotumor tissues collected during revision surgery were degraded by enzyme digestion and cells were typed by flow cytometry. Whole blood chromium and cobalt concentrations were analyzed with mass spectrometry before revision surgery. RESULTS Flow cytometry analysis showed that the peri-implant pseudotumor tissue expressed two principal phenotypes, namely macrophage-dominated and T-lymphocyte-dominated response; the average portions being 54% (macrophages) and 25% (T-lymphocytes) in macrophage-dominated inflammation and 20% (macrophages) and 54% (T-lymphocytes) in T-lymphocyte-dominated response. The percentages of B-lymphocytes and granulocytes were lower in both phenotypes. Interestingly, the levels of blood chromium and cobalt were significantly higher in patients with macrophage-dominated response. CONCLUSIONS The results suggest that the adverse tissue reactions induced by MOM wear particles contain heterogeneous pathogeneses and that the metal levels are an important factor in the determination of the inflammatory phenotype. The present results support the hypothesis that higher metal levels cause cytotoxicity and tissue injury and macrophages are recruited to clear the necrotic debris. On the other hand, the adverse response developed in association with lower metal levels is T-lymphocyte-dominated and is likely to reflect hypersensitivity reaction.
Collapse
Affiliation(s)
- Erja-Leena Paukkeri
- The Immunopharmacology Research Group, University of Tampere School of Medicine and Tampere University Hospital, Tampere, Finland
| | - Riku Korhonen
- The Immunopharmacology Research Group, University of Tampere School of Medicine and Tampere University Hospital, Tampere, Finland
| | - Mari Hämäläinen
- The Immunopharmacology Research Group, University of Tampere School of Medicine and Tampere University Hospital, Tampere, Finland
| | - Marko Pesu
- Immunoregulation, Institute of Biomedical Technology, University of Tampere, Tampere, Finland.,Department of Dermatology, Tampere University Hospital, Tampere, Finland
| | | | - Teemu Moilanen
- The Immunopharmacology Research Group, University of Tampere School of Medicine and Tampere University Hospital, Tampere, Finland.,Coxa Hospital for Joint Replacement, Tampere, Finland
| | - Eeva Moilanen
- The Immunopharmacology Research Group, University of Tampere School of Medicine and Tampere University Hospital, Tampere, Finland
| |
Collapse
|
28
|
Matharu GS, Berryman F, Brash L, Pynsent PB, Treacy RBC, Dunlop DJ. The Effectiveness of Blood Metal Ions in Identifying Patients with Unilateral Birmingham Hip Resurfacing and Corail-Pinnacle Metal-on-Metal Hip Implants at Risk of Adverse Reactions to Metal Debris. J Bone Joint Surg Am 2016; 98:617-26. [PMID: 27098320 DOI: 10.2106/jbjs.15.00340] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND We investigated whether blood metal ions could effectively identify patients with metal-on-metal hip implants with two common designs (Birmingham Hip Resurfacing [BHR] and Corail-Pinnacle) who were at risk of adverse reactions to metal debris. METHODS This single-center, prospective study involved 598 patients with unilateral hip implants (309 patients with the BHR implant and 289 patients with the Corail-Pinnacle implant) undergoing whole blood metal ion sampling at a mean time of 6.9 years. Patients were classified into two groups, one that had adverse reactions to metal debris (those who had to undergo revision for adverse reactions to metal debris or those with adverse reactions to metal debris on imaging; n = 46) and one that did not (n = 552). Three metal ion parameters (cobalt, chromium, and cobalt-chromium ratio) were compared between groups. Optimal metal ion thresholds for identifying patients with adverse reactions to metal debris were determined using receiver operating characteristic analysis. RESULTS All ion parameters were significantly higher (p < 0.0001) in the patients who had adverse reactions to metal debris compared with those who did not. Cobalt maximized the area under the curve for patients with the BHR implant (90.5%) and those with the Corail-Pinnacle implant (79.6%). For patients with the BHR implant, the area under the curve for cobalt was significantly greater than that for the cobalt-chromium ratio (p = 0.0005), but it was not significantly greater than that for chromium (p = 0.8483). For the patients with the Corail-Pinnacle implant, the area under the curve for cobalt was significantly greater than that for chromium (p = 0.0004), but it was similar to that for the cobalt-chromium ratio (p = 0.8139). Optimal blood metal ion thresholds for identifying adverse reactions to metal debris varied between the two different implants. When using cobalt, the optimal threshold for identifying adverse reactions to metal debris was 2.15 μg/L for the BHR group and 3.57 μg/L for the Corail-Pinnacle group. These thresholds had good sensitivities (88.5% for the BHR group and 80.0% for the Corail-Pinnacle group) and specificities (84.5% for the BHR group and 76.2% for the Corail-Pinnacle group), high negative predictive values (98.8% for the BHR group and 98.1% for the Corail-Pinnacle group), and low positive predictive values (34.3% for the BHR group and 20.0% for the Corail-Pinnacle group). The authority thresholds proposed by the United States (3 μg/L and 10 μg/L) and the United Kingdom (7 μg/L) missed more patients with adverse reactions to metal debris at 2.0% to 4.7% (twelve to twenty-eight patients) compared with our implant-specific thresholds at 1.2% (seven patients missed). CONCLUSIONS Patients who underwent metal-on-metal hip arthroplasty performed with unilateral BHR or Corail-Pinnacle implants and who had blood metal ions below our implant-specific thresholds were at low risk of adverse reactions to metal debris. These thresholds could be used to rationalize follow-up resources in asymptomatic patients. Analysis of cobalt alone is acceptable. Implant-specific thresholds were more effective than currently recommended fixed authority thresholds for identifying patients at risk of adverse reactions to metal debris requiring further investigation. LEVEL OF EVIDENCE Diagnostic Level II. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
| | - Fiona Berryman
- The Royal Orthopaedic Hospital, Birmingham, United Kingdom
| | - Lesley Brash
- The Royal Orthopaedic Hospital, Birmingham, United Kingdom
| | - Paul B Pynsent
- The Royal Orthopaedic Hospital, Birmingham, United Kingdom
| | | | - David J Dunlop
- The Royal Orthopaedic Hospital, Birmingham, United Kingdom
| |
Collapse
|
29
|
Repeated metal ion measurement in patients with bilateral metal on metal (ASR™) hip replacements. Orthop Traumatol Surg Res 2016; 102:167-73. [PMID: 26874448 DOI: 10.1016/j.otsr.2015.12.015] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/14/2015] [Revised: 12/13/2015] [Accepted: 12/17/2015] [Indexed: 02/02/2023]
Abstract
BACKGROUND Blood metal ion measurements have become a cornerstone in the surveillance of metal-on-metal (MoM) hip replacements. Interpretation of these levels in patients with bilateral MoM hip replacements, however, is challenging. We therefore asked (1) if there is a clinically significant change in whole blood (WB) Co or Cr levels in repeated WB assessment in patients operated on with bilateral ASR hip replacements, and (2) what proportion of patients has WB Co or Cr level below the previously established safe upper limits (SUL) (Co<5.0μg/L, Cr<7.4μg/L) in the repeated WB metal ion assessment. HYPOTHESIS We hypothesized that there is a significant difference between repeated Co and Cr level measurement performed within one year±4 months interval in patients with bilateral ASR hip replacements. MATERIALS AND METHODS We identified all patients (n=139) who had received bilateral ASR hip replacements (278 hips). Patients (n=76, 152 hips) who had undergone two blood metal ion measurements within eight to sixteen months' time interval were included in the study analysis. Study cohort included 38 patients with bilateral ASR hip resurfacings (mean age 53 years, median follow-up 4.6 years, median femoral diameter 51mm) and 38 patients with bilateral ASR XL total hip replacements (mean age 60 years, median follow-up 3.6 years, median femoral diameter 49mm). RESULTS There was no significant change in Co and Cr levels between the repeated measurements in the HR cohort. Both Co and Cr were significantly higher in the THR cohort in the repeated measurement (Co: 8.3μg/L vs. 12.6μg/L, Cr: 3.15μg/L vs. 3.4μg/L, both P<0.001). WB Co and Cr levels remained below SUL and within their initial values during a mean one-year measurement interval in the majority of patients with bilateral high risk HR device. In contrast to this, 21.1% of patients with THRs had WB Co ion levels exceeding the SUL in the first measurement. WB Co values significantly increased over the measurement interval in the THR group. DISCUSSION Annual blood metal ion measurement is not useful in patients with bilateral hip resurfacings who have undergone at least one preliminary screening including both metal ion measurement and cross-sectional imaging. It seems, however, to be beneficial in patients with bilateral high risk MoM THR. LEVEL OF EVIDENCE Level III (retrospective comparative study).
Collapse
|
30
|
Madanat R, Hussey DK, Donahue GS, Potter HG, Wallace R, Bragdon CR, Muratoglu OK, Malchau H. The Symmetry of Adverse Local Tissue Reactions in Patients with Bilateral Simultaneous and Sequential ASR Hip Replacement. J Arthroplasty 2015; 30:1794-8. [PMID: 26055146 DOI: 10.1016/j.arth.2015.04.036] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/10/2015] [Revised: 04/13/2015] [Accepted: 04/27/2015] [Indexed: 02/01/2023] Open
Abstract
The purpose of this study was to evaluate whether patients with bilateral metal-on-metal (MoM) hip replacements have symmetric adverse local tissue reactions (ALTRs) at follow-up. An MRI of both hips was performed at a mean time of six years after surgery in 43 patients. The prevalence and severity of ALTRs were found to be similar in simultaneous hips but differences were observed in sequential hips. The order and timing of sequential hip arthroplasties did not affect the severity of ALTRs. Thus, in addition to metal ion exposure from an earlier MoM implant other factors may also play a role in the progression of ALTRs. Bilateral implants should be given special consideration in risk stratification algorithms for management of patients with MoM hip arthroplasty.
Collapse
Affiliation(s)
- Rami Madanat
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts; Harvard Medical School, Department of Orthopaedic Surgery, Boston, Massachusetts
| | - Daniel K Hussey
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts
| | - Gabrielle S Donahue
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts
| | - Hollis G Potter
- Department of Radiology and Imaging, Hospital for Special Surgery, New York, New York
| | | | - Charles R Bragdon
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts; Harvard Medical School, Department of Orthopaedic Surgery, Boston, Massachusetts
| | - Orhun K Muratoglu
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts; Harvard Medical School, Department of Orthopaedic Surgery, Boston, Massachusetts
| | - Henrik Malchau
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts; Harvard Medical School, Department of Orthopaedic Surgery, Boston, Massachusetts
| |
Collapse
|
31
|
Matharu GS, Mellon SJ, Murray DW, Pandit HG. Follow-Up of Metal-on-Metal Hip Arthroplasty Patients Is Currently Not Evidence Based or Cost Effective. J Arthroplasty 2015; 30:1317-23. [PMID: 25861918 DOI: 10.1016/j.arth.2015.03.009] [Citation(s) in RCA: 51] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/04/2014] [Revised: 02/19/2015] [Accepted: 03/07/2015] [Indexed: 02/01/2023] Open
Abstract
Over one-million patients worldwide have received metal-on-metal (MoM) hip arthroplasties with a significant proportion requiring revision surgery in the short-term for adverse reaction to metal debris (ARMD). Worldwide authorities have subsequently issued follow-up guidance for MoM hip patients. This article compares follow-up guidelines for MoM hips published by five worldwide authorities, analyses these protocols in relation to published evidence, and assesses the financial implications of these guidelines. A number of major differences exist between authorities regarding patient follow-up, with vast cost differences between protocols (£84 to £988/patient/year for stemmed MoM hips and £0 to £988/patient/year for hip resurfacing). Current worldwide guidance is neither evidence-based nor financially sustainable with most protocols lacking the sensitivity to detect asymptomatic ARMD lesions.
Collapse
Affiliation(s)
- Gulraj S Matharu
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Nuffield Orthopaedic Centre, Oxford, United Kingdom, OX3 7LD
| | - Stephen J Mellon
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Nuffield Orthopaedic Centre, Oxford, United Kingdom, OX3 7LD
| | - David W Murray
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Nuffield Orthopaedic Centre, Oxford, United Kingdom, OX3 7LD
| | - Hemant G Pandit
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Nuffield Orthopaedic Centre, Oxford, United Kingdom, OX3 7LD
| |
Collapse
|
32
|
Influence of implant design on blood metal ion concentrations in metal-on-metal total hip replacement patients. INTERNATIONAL ORTHOPAEDICS 2015; 39:1803-11. [PMID: 25655902 DOI: 10.1007/s00264-014-2644-z] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/27/2014] [Accepted: 12/14/2014] [Indexed: 02/06/2023]
Abstract
PURPOSE Most factors considered to affect blood metal ions following metal-on-metal hip replacement are based on hip resurfacing patients. The study aims were to determine which factors affect blood metal ion concentrations following metal-on-metal total hip replacement (MoM THR). METHODS All unilateral MoM THR patients at one centre with whole-blood cobalt (Co) and chromium (Cr) concentrations measured up to May 2013 were included. Blood sampling was at a mean of 4.5 years (range 1.1-11.8 years) postoperatively. RESULTS Of 496 patients (mean age 59.1 years; 52.8% male), blood metal ions >7 μg/l were observed in 9.7% (n = 48). Large femoral head sizes (≥38 mm) had significantly higher (p < 0.0001) blood metal ions than smaller sizes (28/36 mm). Corail-Pinnacle implants produced significantly lower blood metal ions compared to other implant designs (p < 0.01 Co and Cr). Univariate linear regression demonstrated the only significant predictors of both blood Co and Cr concentrations were femoral head size (R(2) = 8.6% Co and R(2) = 3.3% Cr, both p < 0.0001) and implant design (R(2) = 8.8%, p = 0.005 Co and R(2) = 5.1%, p = 0.003 Cr). When the three THR implant design groups (Corail-Pinnacle, Synergy, Other) were analysed separately, femoral head size no longer significantly affected blood metal ions in any of the three implant design groups. CONCLUSIONS Implant design was the most important factor affecting blood metal ion concentrations. We recommend the regularity of follow-up be tailored to survival rates of various MoM THR designs rather than according to femoral head size.
Collapse
|
33
|
Matharu GS, Mellon SJ, Murray DW, Pandit HG. Follow-up guidance for metal-on-metal hip replacement patients should be updated. INTERNATIONAL ORTHOPAEDICS 2015; 39:609-10. [PMID: 25720361 DOI: 10.1007/s00264-015-2667-0] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/19/2014] [Accepted: 01/02/2015] [Indexed: 11/25/2022]
Affiliation(s)
- Gulraj S Matharu
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Nuffield Orthopaedic Centre, Oxford, UK,
| | | | | | | |
Collapse
|
34
|
Reito A, Moilanen T, Puolakka T, Pajamäki J, Eskelinen A. Reply to comments on Reito et al.: Repeated metal ion measurements in patients with high risk metal-on-metal hip replacement. INTERNATIONAL ORTHOPAEDICS 2015; 39:611-2. [PMID: 25592832 DOI: 10.1007/s00264-015-2666-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/02/2015] [Accepted: 01/02/2015] [Indexed: 11/30/2022]
Affiliation(s)
- Aleksi Reito
- Coxa Hospital for Joint Replacement, Tampere, Finland
| | | | | | | | | |
Collapse
|