1
|
Mabrouk A, An JS, Glauco L, Jacque C, Kley K, Sharma A, Ollivier M. The joint line convergence angle (JLCA) correlates with intra-articular arthritis. Knee Surg Sports Traumatol Arthrosc 2023; 31:5673-5680. [PMID: 37884727 DOI: 10.1007/s00167-023-07616-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/28/2023] [Accepted: 09/29/2023] [Indexed: 10/28/2023]
Abstract
PURPOSE Knees with unicompartmental varus osteoarthritis (OA) usually display a combination of tibiofemoral bony deformity and increased joint line convergence angle (JLCA). The JLCA is a product of intra-articular deformity and lateral soft tissue laxity. This study aims to define the correlation between the JLCA and progression of OA. METHODS A retrospective radiological analysis of 501 patients, who underwent either high tibial osteotomy (HTO) or unicompartmental knee arthroplasty (UKA), was performed. The preoperative OA grade was reported based on the Ahlbäck and the Kellgren-Lawrence (KL). The hip-knee-ankle angle (HKA), the medial proximal tibial angle (MPTA), the mechanical lateral distal femoral angle (mLDFA) and the joint line convergence angle (JLCA) were recorded. The primary outcome was the relationship between the JLCA values and the OA grade. The secondary outcomes were comparing the JLCA and other alignment parameter values between HTO and UKA groups. RESULTS A total of 501 (59.3% females n = 297) cases were included, comprising 293 cases of HTO and 208 cases of UKA. Patients had a mean age of 57.63 ± 8.97 years, a mean BMI of 28.37 ± 7.39 kg/m2. Patients with Ahlbäck grade 2 represented 49.3% of all patients (n = 247) and patients with KL grade 3 represented 54.7% of all patients (n = 274). A high JLCA was observed in both groups. The reported mean JLCA in the UKA group was 3.69 ± 2.1°, and in the HTO group was 2.93 ± 1.82. There was a significant association between the increase in the JLCA and the progression of OA based on both the Ahlbäck and KL grades (both p values < 0.001). The mean JLCA in patients with Ahlbäck grades 1 and 4 was 1.48 ± 1.32°, and 7 ± 0.93°, respectively. The mean JLCA in patients with KL grades 1 and 4 was 1.77 ± 1.42°, and 4.89 ± 1.73°, respectively. The mean recorded preoperative HKA angle in the UKA group was 175.06 ± 3.08°, and in the HTO group was 173.26 ± 3.02°, whereas the mean MPTA was 88.63 ± 1.72° for the UKA group and 89.31 ± 2.29° for the HTO group. CONCLUSION The JLCA progressively increases with osteoarthritis progression in patients with unicompartmental varus knee osteoarthritis. The JLCA can potentially be used as a grading parameter for osteoarthritis progression akin to Ahlbäck and Kellgren-Lawrence grading systems.
Collapse
Affiliation(s)
- Ahmed Mabrouk
- Mid Yorkshire Teaching Hospitals, Yorkshire, UK
- Institute for Locomotion, Aix-Marseille University, CNRS Sainte-Marguerite Hospital, APHM, Marseille, ISM, France
| | - Jae-Sung An
- Institute for Locomotion, Aix-Marseille University, CNRS Sainte-Marguerite Hospital, APHM, Marseille, ISM, France
| | - Loddo Glauco
- Institute for Locomotion, Aix-Marseille University, CNRS Sainte-Marguerite Hospital, APHM, Marseille, ISM, France
| | - Christophe Jacque
- Institute for Locomotion, Aix-Marseille University, CNRS Sainte-Marguerite Hospital, APHM, Marseille, ISM, France
| | | | | | - Matthieu Ollivier
- Institute for Locomotion, Aix-Marseille University, CNRS Sainte-Marguerite Hospital, APHM, Marseille, ISM, France.
| |
Collapse
|
2
|
Katagiri H, Nakagawa Y, Miyatake K, Ohara T, Shioda M, Sekiya I, Koga H. Short-Term Outcomes after High Tibial Osteotomy Aimed at Neutral Alignment Combined with Arthroscopic Centralization of Medial Meniscus in Osteoarthritis Patients. J Knee Surg 2023; 36:261-268. [PMID: 34261157 DOI: 10.1055/s-0041-1731738] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
The study aimed to improve the long-term outcomes of open-wedge high tibial osteotomy (OWHTO); procedures combining OWHTO aimed at neutral alignment and arthroscopic centralization for meniscal extrusion have been introduced. The present study evaluated short-term patient-reported outcome measures; namely, the patient subjective satisfaction scores and Numeric Rating Scale (NRS) for walking pain after OWHTO aimed at neutral alignment with and without arthroscopic centralization for an extruded medial meniscus. A retrospective review of 50 primary OWHTO patients was conducted. Thirty-nine patients were included in the analysis after applying the exclusion criteria. The centralization group included 21 patients with knee osteoarthritis patients who underwent the OWHTO with arthroscopic meniscal centralization, while the control group included 18 patients who underwent OWHTO alone. The patient subjective satisfaction scores and NRS for walking pain were recorded at outpatient visits from before surgery to 3 years after surgery. In terms of the Lysholm knee scale, International Knee Documentation Committee subjective score, and Knee Osteoarthritis Outcome Score, the latest data (at least 2 years after surgery) were reviewed. Radiographic changes in joint space width and joint line congruence angle were measured 2 years postoperatively. Patient demographic data were also reviewed. One patient in the centralization group experienced a superficial surgical site infection. The patient subjective satisfaction and NRS scores for walking pain gradually improved by 1 year after surgery and were sustained until 3 years after surgery in both groups, with no significant difference between the groups. The course of patient-reported outcome measures from before surgery to 3 years after surgery for solely OWHTO aimed at neutral alignment and OWHTO aimed at neutral alignment with arthroscopic centralization showed the similar trends.
Collapse
Affiliation(s)
- Hiroki Katagiri
- Department of Joint Surgery and Sports Medicine, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Bunkyo-ku, Tokyo, Japan.,Department of Orthopaedic Surgery, Tokyo Medical and Dental University Hospital of Medicine, Bunkyo-ku, Tokyo, Japan
| | - Yusuke Nakagawa
- Department of Joint Surgery and Sports Medicine, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Bunkyo-ku, Tokyo, Japan.,Department of Orthopaedic Surgery, Tokyo Medical and Dental University Hospital of Medicine, Bunkyo-ku, Tokyo, Japan
| | - Kazumasa Miyatake
- Department of Joint Surgery and Sports Medicine, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Bunkyo-ku, Tokyo, Japan.,Department of Orthopaedic Surgery, Tokyo Medical and Dental University Hospital of Medicine, Bunkyo-ku, Tokyo, Japan
| | - Toshiyuki Ohara
- Department of Orthopaedic Surgery, Tokyo Medical and Dental University Hospital of Medicine, Bunkyo-ku, Tokyo, Japan
| | - Mikio Shioda
- Department of Orthopaedic Surgery, Tokyo Medical and Dental University Hospital of Medicine, Bunkyo-ku, Tokyo, Japan
| | - Ichiro Sekiya
- Center for Stem Cell and Regenerative Medicine, Tokyo Medical and Dental University, Tokyo, Bunkyo-ku, Tokyo, Japan
| | - Hideyuki Koga
- Department of Joint Surgery and Sports Medicine, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Bunkyo-ku, Tokyo, Japan.,Department of Orthopaedic Surgery, Tokyo Medical and Dental University Hospital of Medicine, Bunkyo-ku, Tokyo, Japan
| |
Collapse
|
3
|
Lu Y, Wang X, Yang B, Xu Z, Zhang B, Jia B, He J, Qi L, Wang M, Qiao F. Application of SolidWorks software in preoperative planning of high tibial osteotomy. Front Surg 2023; 9:951820. [PMID: 36684138 PMCID: PMC9852509 DOI: 10.3389/fsurg.2022.951820] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2022] [Accepted: 09/27/2022] [Indexed: 01/08/2023] Open
Abstract
Purpose Open-wedge high tibial osteotomy (HTO) is a common surgical treatment for medial osteoarthritis in young and active patients. The accuracy of osteotomy is closely associated with postoperative efficacy. The accuracy of digital preoperative planning is higher than that of the preoperative manual measurement and several computer software with varying accuracy and convenience are used for digital preoperative planning. This study aimed to use the SolidWorks software for HTO preoperative planning and to determine its accuracy and reliability in HTO preoperative planning. Methods We reviewed the data of 28 patients with 54 with medial compartment knee arthritis who underwent open-wedge HTO preoperative planning using SolidWorks between June 2019 and March 2021. The standard anteroposterior standing whole-leg radiographs were assessed before and 6 weeks after the surgery. The correction angle, weight-bearing line (WBL) ratio, mechanical femorotibial angle (mFTA), and medial proximal tibial angle (MPTA) before and after the surgery were compared. The clinical results were evaluated using the Knee Society score. Results At 6 weeks after the surgery, the WBL ratio was corrected from 16.8% to 50.5%, mFTA was corrected from 6.4° varus to 1.2° valgus, and MPTA was corrected from 83.4° to 89.3°. No significant difference was observed between the predicted correction angle before the surgery and the correction angle measured 6 weeks after the surgery (t = -1.745, p = 0.087). The knee score and function score of Knee Society increased from 76.4 and 80.7 before surgery to 95.0 and 95.7, respectively. Conclusions The SolidWorks software showed high accuracy and reliability in preoperative planning of open-wedge HTO in patients with medial compartment knee arthritis.
Collapse
Affiliation(s)
- Yufeng Lu
- Department of Integrated Traditional Chinese Medicine (TCM) and Western Medicine Orthopedics, Honghui Hospital, Xi'an Jiaotong University, Xi'an, China
| | - Xue Wang
- Department of Emergency Medicine, Affiliated Hospital of Shaanxi University of Traditional Chinese Medicine, Xianyang, China
| | - Bo Yang
- Graduate School, Xi'an Medical University, Xi'an, China
| | - Zhaochen Xu
- Department of Integrated Traditional Chinese Medicine (TCM) and Western Medicine Orthopedics, Honghui Hospital, Xi'an Jiaotong University, Xi'an, China
| | - Baogang Zhang
- Department of Integrated Traditional Chinese Medicine (TCM) and Western Medicine Orthopedics, Honghui Hospital, Xi'an Jiaotong University, Xi'an, China
| | - Bin Jia
- Department of Integrated Traditional Chinese Medicine (TCM) and Western Medicine Orthopedics, Honghui Hospital, Xi'an Jiaotong University, Xi'an, China
| | - Jinlong He
- Department of Integrated Traditional Chinese Medicine (TCM) and Western Medicine Orthopedics, Honghui Hospital, Xi'an Jiaotong University, Xi'an, China
| | - Liang Qi
- Department of Integrated Traditional Chinese Medicine (TCM) and Western Medicine Orthopedics, Honghui Hospital, Xi'an Jiaotong University, Xi'an, China
| | - Min Wang
- Department of Integrated Traditional Chinese Medicine (TCM) and Western Medicine Orthopedics, Honghui Hospital, Xi'an Jiaotong University, Xi'an, China
| | - Feng Qiao
- Department of Integrated Traditional Chinese Medicine (TCM) and Western Medicine Orthopedics, Honghui Hospital, Xi'an Jiaotong University, Xi'an, China
| |
Collapse
|
4
|
Xu K, Wang W, Wang Q, Sun J, Fang C, Sun Y, Shi T, Wu X, Yan Q. Comparison of computer-assisted navigated technology and conventional technology in high tibial osteotomy (HTO): a meta-analysis. Comput Assist Surg (Abingdon) 2022; 27:63-73. [PMID: 35882055 DOI: 10.1080/24699322.2022.2078739] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/16/2022] Open
Abstract
BACKGROUND Though some studies have reported navigated high tibial osteotomy (HTO) is a useful procedure to correct knee deformity. There is still great controversy whether navigated HTO can achieve better accuracy of limb alignment and greater clinical outcomes. Current meta-analysis was conducted to investigate whether better radiographic outcomes and clinical outcomes could be acquired in navigated HTO compared with the conventional procedure. METHOD We conducted a literature search in the electronic databases, including Medline, Embase, the Cochrane Library, and Web of Science. We identified studies published before August 2020. We also checked the references of the related articles for any relevant studies. We strictly followed the Preferred Reporting Items for Systematics reviews and Meta-Analysis (PRISMA) guidelines in this review. This research was performed using Review Manager 5.4 software. RESULTS Fourteen articles were included, involving 1399 knees. Our meta-analysis indicated that patients undergoing navigated HTO had significantly better outcomes in outliers of aimed limb alignment (RD=-0.24, 95% CI: =-0.34 to -0.13, p < 0.01), outliers of aimed tibial posterior slope (TPS) (RD=-0.41, 95% CI: -0.51 to -0.30, p < 0.01), Range of Motion (ROM) (MD = 6.37, 95%CI: 0.83-11.91, p = 0.02), and American knee society knee score (AKS knee score) (MD = 3.88, 95%CI: 1.37-6.39, p = 0.002). No significant differences were found in Lysholm score (MD = 1.30, 95%CI: -0.31 to 2.90, p = 0.11), American knee society function score (AKS function score) (RD = 1.42, 95%CI: -0.15 to 2.99, p = 0.08), complications (RD=-0.01, 95% CI: = -0.05 to 0.04, p = 0.77), delayed union (RD=-0.01, 95% CI: = -0.02 to 0.03, p = 0.59), and reoperation (RD = 0, 95% CI: -0.09 to 0.10, p = 0.98) between the two groups. The operation time in the navigated group was 15.46 min longer than in the conventional group. CONCLUSION Navigated HTO provided more accurate and reproducible radiographic outcomes in the correction of the malalignment than conventional techniques, and there is no difference in the risk of complications compared with conventional HTO. However, it is unclear whether navigation HTO can achieve better clinical results. More randomized controlled trials (RCTs) with high quality, large sample size, and sufficient follow-up period are required.
Collapse
Affiliation(s)
- Keteng Xu
- Department of Joint Surgery, Huangshan City People's Hospital, Huangshan, Anhui, China
| | - Weichao Wang
- Department of Joint Surgery, Huangshan City People's Hospital, Huangshan, Anhui, China
| | - Qin Wang
- Department of Joint Surgery, Huangshan City People's Hospital, Huangshan, Anhui, China
| | - Jun Sun
- Department of Joint Surgery, Huangshan City People's Hospital, Huangshan, Anhui, China
| | - Chen Fang
- Department of Joint Surgery, Huangshan City People's Hospital, Huangshan, Anhui, China
| | - Yusheng Sun
- Department of Joint Surgery, Huangshan City People's Hospital, Huangshan, Anhui, China
| | - Tulong Shi
- Department of Joint Surgery, Huangshan City People's Hospital, Huangshan, Anhui, China
| | - Xun Wu
- Department of Joint Surgery, Huangshan City People's Hospital, Huangshan, Anhui, China
| | - Qing Yan
- Department of Joint Surgery, Huangshan City People's Hospital, Huangshan, Anhui, China
| |
Collapse
|
5
|
Clinical efficacy and feasibility of laser correction technology with an ordinary laser pen and surgical instrument box in open-wedge high tibial osteotomy. BMC Musculoskelet Disord 2022; 23:1019. [PMID: 36435822 PMCID: PMC9701429 DOI: 10.1186/s12891-022-05993-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/09/2022] [Accepted: 11/16/2022] [Indexed: 11/28/2022] Open
Abstract
Abstract
Background
The clinical outcomes of open-wedge high tibial osteotomy (OWHTO) for medial knee osteoarthritis primarily depend on the corrective precision. The present study aimed to determine the efficacy and feasibility of laser correction technology with an ordinary laser pen and surgical instrument box.
Methods
This prospective and randomized trial included 71 patients randomly divided into laser (n = 36) and traditional groups (n = 35). In the laser group, the hip centre, knee (Fujisawa point), and ankle centre were located preoperatively using the surgical instrument box lid. The leg was aligned with an ordinary laser pen. In the traditional group, the lower limb alignment was corrected by a metal cable. Radiation exposure, operative time, and rate of outliers (lower limb force line does not pass through 62–66% of the lateral tibial plateau) were evaluated. The visual analogue scale (VAS) and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) scores were recorded. After 24 months, the femoral tibial angle (FTA), medial proximal tibial angle (MPTA), and posterior slope angle (PSA), were recorded. The Kaplan-Meier method was used to evaluate the survival time of affected knees, and postoperative complications were recorded.
Results
The radiation exposure, operative time and rate of outliers were lower in the laser correction group (P < 0.05). Six months postoperatively, the VAS and WOMAC scores were significantly improved in both groups (P < 0.001). At 24 months, the FTA, MPTA, and PSA were corrected in both groups (P < 0.001). There were no differences in the postoperative knee survival time from OWHTO to knee arthroplasty between the groups or postoperative complications (P = 0.53; P = 0.61).
Conclusions
Laser correction technology can effectively reduce radiation exposure, the operative time, and the rate of outliers (trial identification number (retrospectively registered): ChiCTR2200060480; date of register: 03/06/2022).
Collapse
|
6
|
Van fraeyenhove B, Oussedik S. Navigation Guided Corrective Osteotomy (based on surgical technique). OPER TECHN SPORT MED 2022. [DOI: 10.1016/j.otsm.2022.150935] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
7
|
Kandhari V, Angadi D, Myat D, Fritsch B, Parker D, Coolican M. Long Term Outcomes of Computer-Navigated Lateral Opening Wedge Distal Femoral Osteotomy for Lateral Compartment Knee Arthrosis. Rev Bras Ortop 2022; 57:96-102. [PMID: 35198115 PMCID: PMC8856845 DOI: 10.1055/s-0040-1716765] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2020] [Accepted: 07/06/2020] [Indexed: 11/04/2022] Open
Abstract
Objective The primary aim of the present study was to evaluate the long-term outcomes including survivorship of computer navigated distal femoral lateral opening wedge osteotomy (DFLOWO). The secondary aim was to identify the potential factors that may influence its survivorship. Methods A retrospective analysis of prospectively collected data for patients with lateral compartment arthritis who underwent navigated DFLOWO from December 2006 to November 2012 was performed. The International Knee Documentation Committee (IKDC) and Knee Injury and Osteoarthritis Outcome Score (KOOS) scores were analyzed for outcome measures. Conversion to arthroplasty during the follow-up was the end point. Results A total of 19 DFLOWOs were performed in 17 patients with a mean age of 46.6 ± 6.5 years formed the study cohort. The coronal alignment was corrected from a mean of 7.1° (2-11°) valgus to a mean of 2.1° (0.5°-3°) varus. The IKDC scores improved from mean of 39 preoperatively to 53 at the mean long-term follow-up of 9.1 years. The mean KOOS scores at the long-term follow-up were pain 71, symptoms 56, activities of daily living 82, sports and recreation 59, quality of life 43. Survivorship of the DFLOWO was 78.9% at a follow-up of 9.1 years. Presence of ≥ grade 2 according to the International Cartilage Repair Society (ICRS) cartilage degeneration in the medial compartment of the knee and >7° preoperative valgus deformity were strongly correlated with conversion to total knee arthroplasty (TKA) at the long-term follow-up ( r = 0.66). Conclusions Computer navigated DFLOWO has satisfactory clinical outcomes and 79% survivorship in long-term follow-up. Presence of more than ICRS ≥ grade 2 degenerative changes in the medial compartment of knee with > 7° preoperative valgus deformity negatively affects the survivorship of DFLOWO in the long-term follow-up.
Collapse
Affiliation(s)
- Vikram Kandhari
- Departamento de Cirurgia Ortopédica do Joelho, Instituto de Pesquisa Ortopédica de Sydney, Chatswood, Sydney, NSW, Austrália
| | - Darshan Angadi
- Departamento de Cirurgia Ortopédica do Joelho, Instituto de Pesquisa Ortopédica de Sydney, Chatswood, Sydney, NSW, Austrália
| | - Darli Myat
- Departamento de Cirurgia Ortopédica do Joelho, Instituto de Pesquisa Ortopédica de Sydney, Chatswood, Sydney, NSW, Austrália
| | - Brett Fritsch
- Departamento de Cirurgia Ortopédica do Joelho, Instituto de Pesquisa Ortopédica de Sydney, Chatswood, Sydney, NSW, Austrália
| | - David Parker
- Departamento de Cirurgia Ortopédica do Joelho, Instituto de Pesquisa Ortopédica de Sydney, Chatswood, Sydney, NSW, Austrália
| | - Myles Coolican
- Departamento de Cirurgia Ortopédica do Joelho, Instituto de Pesquisa Ortopédica de Sydney, Chatswood, Sydney, NSW, Austrália
| |
Collapse
|
8
|
Cerciello S, Ollivier M, Corona K, Kaocoglu B, Seil R. CAS and PSI increase coronal alignment accuracy and reduce outliers when compared to traditional technique of medial open wedge high tibial osteotomy: a meta-analysis. Knee Surg Sports Traumatol Arthrosc 2022; 30:555-566. [PMID: 32910222 DOI: 10.1007/s00167-020-06253-5] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/14/2020] [Accepted: 08/21/2020] [Indexed: 10/23/2022]
Abstract
PURPOSE Medial open-wedge high tibial osteotomy (MOWHTO) is an accepted option in the treatment of medial compartment osteoarthritis of the knee in young and active patients. Functional results are closely correlated to the correction of the mechanical axis of the lower limb. Although several angular and geometrical methods and values have been proposed in the past, the ideal target is still debated. In addition, it is important to have a deep correlation between the planned correction and the achieved correction after surgery. The aim of the present systematic review was to identify the ideal coronal correction after MOWHTO and the most accurate method to achieve it. METHODS A systematic review of the literature was completed on July 3rd 2020 in the Pubmed, Medline, Cochrane Reviews, and Google Scholar databases using the Medical Subject Headings (MeSH) terms: "high tibial osteotomy" AND "accuracy" OR "planning". RESULTS 28 studies were included; 18 were focused on computer-assisted surgery (CAS) and 10 on patient-specific instrumentation (PSI). There were 598 patients in the CAS group and 501 in the control group; the rate of outliers was 16% and 38.2% respectively (P = 0.04), while there was no significant difference between the two groups (SMD = - 0.10; 95% CI 1.31 to 1.12; P = n.s.) in terms of coronal accuracy. Likewise, there were 318 patients in the PSI group and 40 in the control group; the rate of outliers was 15% and 40% respectively (P = 0.98), while there was no significant difference between the two groups (SMD = 0.01; 95% CI 0.58 to 0.59; P = 0.98). CONCLUSIONS A statistically significant reduced outlier rate and a non-significant increased accuracy emerged with the use of CAS when compared to the traditional surgical technique, whereas the results of PSI were still inconclusive. In addition, it emerged clearly that no consensus still exists on the ideal correction target to be achieved after surgery. LEVEL OF EVIDENCE III.
Collapse
Affiliation(s)
- S Cerciello
- Casa di Cura Villa Betania, Rome, Italy.,Marrelli Hospital, Crotone, Italy
| | - M Ollivier
- Department of Orthopedics and Traumatology, Institute for Locomotion, Sainte-Marguerite Hospital, Aix Marseille Univ, APHM, CNRS, ISM, Marseille, France
| | - K Corona
- Department of Medicine and Health Sciences "Vincenzo Tiberio", University of Molise, Campobasso, Italy.
| | - B Kaocoglu
- Department of Orthopaedics and Traumatology, Acibadem University, İstanbul, Turkey
| | - R Seil
- Department of Orthopaedic Surgery, Centre Hospitalier de Luxembourg-Clinique d'Eich, 78 Rue d'Eich, 1460, Luxembourg, Luxembourg.,Sports Medicine Research Laboratory, Luxembourg Institute of Health, 76 Rue d'Eich, 1460, Luxembourg, Luxembourg.,Sports Medicine and Science, Luxembourg Institute of Research in Orthopaedics, 76 Rue d'Eich, 1460, Luxembourg, Luxembourg
| |
Collapse
|
9
|
Opening Wedge High Tibial Osteotomy with Combined Use of Patient-Specific 3D-Printed Plates and Taylor Spatial Frame for the Treatment of Knee Osteoarthritis. Pain Res Manag 2021; 2021:8609921. [PMID: 34900072 PMCID: PMC8654534 DOI: 10.1155/2021/8609921] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2021] [Accepted: 11/13/2021] [Indexed: 12/13/2022]
Abstract
Background High tibial osteotomy (HTO) is used to treat medial degeneration of the osteoarthritis (OA) knee. However, shortcomings still exist in the current procedure, like unprecise creation, inability to correct knee rotation, and internal fixed failure. Here, we reported a novel procedure: patient-specific 3D-printed plates for opening wedge high tibial osteotomy (OWHTO) combined with Taylor spatial frame (TSF). The detailed technique was described, and the clinical outcomes were evaluated. Methods We prospectively evaluate outcomes of patient-specific 3D-printed plates for OWHTO with use of TSF in 25 patients with knee OA and varus alignment. Postoperative efficacy was evaluated using the HSS knee score, pain visual simulation score (VAS), and knee joint motion (ROM), and lower limb alignment was evaluated by measuring femorotibial angle (FTA) and hip-knee-ankle (HKA). Results and Conclusion. All patients did not experience complications such as wound infection, nerve damage, or bone amputation. 25 patients were followed up for 6–18 months. The bony union at bone amputation was achieved in 3 months after surgery, and the pain symptoms were significantly alleviated or disappeared. The VAS score was significantly reduced in 6 months after surgery compared with preoperative; the HSSS score was significantly added in 6 months after surgery compared with preoperative. The ROM of knee joint increased significantly 6 months after operation compared with that before operation, and the difference was statically significant (P < 0.05). The FTA and HKA after operation were significantly superior to that before operation, and the difference was statically significant (P < 0.01). Conclusions Our study showed that patient-specific 3D-printed plates for HTO with the use of TSF have the advantages of small trauma, few complications, simple operation, and fast recovery in treating knee OA and varus alignment.
Collapse
|
10
|
Tardy N, Steltzlen C, Bouguennec N, Cartier JL, Mertl P, Batailler C, Hanouz JL, Rochcongar G, Fayard JM. Is patient-specific instrumentation more precise than conventional techniques and navigation in achieving planned correction in high tibial osteotomy? Orthop Traumatol Surg Res 2020; 106:S231-S236. [PMID: 32943382 DOI: 10.1016/j.otsr.2020.08.009] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/01/2020] [Accepted: 07/28/2020] [Indexed: 02/03/2023]
Abstract
INTRODUCTION Preoperative planning in high tibial osteotomy (HTO) is a critical step for achieving the desired correction and a clinically satisfactory outcome. Conventional radiography, navigation assistance and patient-specific instrumentation (PSI) are the 3 means of planning, but no prospective studies have compared precision between the 3. The aims of the present study were: (1) to analyze and compare correction precision between the 3 planning approaches at 1 year's follow-up; (2) to compare results to those reported in the literature; and (3) to analyze factors influencing the achievement of planned correction. HYPOTHESIS The study hypothesis was that PSI provides more precise and reproducible planned correction than conventional methods or navigation. MATERIAL AND METHOD Between June 2017 and June 2018, a multicenter non-randomized prospective observational study was conducted in 11 centers. One hundred and twenty-six patients with Ahlbäck grade I, II or III idiopathic medial tibiofemoral osteoarthritis with stable knee were included and allocated to 3 preoperative planning groups: conventional (group 1), navigation (group 2) and PSI (group 3). Mean age at surgery was 51.2 years (range, 19-69 years; median, 53.2 years); 100 male, 26 female. Complete weight-bearing radiographic work-up was performed preoperatively and at 1 year's follow-up. The PSI group also underwent CT as part of guide production. Target angular correction and mechanical Hip-Knee-Ankle (HKA) axis were set preoperatively. The main endpoint was the difference between planned HKA and HKA at a minimum 12 months. RESULTS Mean HKA difference was 1.1±3 in group 1, 2.1±2.6 in group 2 and 0.3±3.1 in group 3. Precision was better with PSI, but not significantly when comparing all 3 groups together. On pairwise intergroup comparison, there was a significant difference only between groups 2 and 3, in favor of PSI (P=0.011). DISCUSSION None of the 3 techniques demonstrated superiority in achieving target correction at 1 year. The study hypothesis was thus not confirmed. All 3 techniques proved reliable and precise in HTO planning. LEVEL OF EVIDENCE III, prospective non-randomized comparative study.
Collapse
Affiliation(s)
- Nicolas Tardy
- Centre Ostéo-Articulaire des Cèdres, Clinique des Cèdres, 5, rue des Tropiques, 38130 Echirolles, France.
| | - Camille Steltzlen
- Service de Chirurgie Orthopédique, Hôpital Mignot, 177, rue de Versailles, 78150 Le Chesnay, France
| | - Nicolas Bouguennec
- Clinique du Sport de Bordeaux-Mérignac, 2, rue Georges-Nègrevergne, 33700 Mérignac, France
| | - Jean-Loup Cartier
- Clinique Des Alpes Du Sud, 3, rue Antonin Coronat, 05000 Gap, France
| | - Patrice Mertl
- Service de Chirurgie Orthopédique, CHU Amiens-Picardie Site Sud, 1, rond-point du Professeur Christian-Cabrol, 80054 Amiens cedex 1, France
| | - Cécile Batailler
- Service de Chirurgie Orthopédique, Hôpital de la Croix-Rousse, 103, grande rue de la Croix Rousse, 69317 cedex 04 Lyon, France
| | - Jean-Luc Hanouz
- Service d'Anesthésie Réanimation, CHU de Caen, avenue Côte De Nacre, 14033 Caen, France
| | - Goulven Rochcongar
- Département de Chirurgie Orthopédique et Traumatologique, Niveau 11, Inserm U1075 COMETE "Mobilité: Attention, Orientation & Chronobiologie", Université de Caen, Basse-Normandie, CHU de Caen, avenue de la Côte-de-Nacre, 14033 Caen cedex, France
| | - Jean-Marie Fayard
- Ramsay Générale de Santé, Hôpital Privé Jean-Mermoz, Centre Orthopédique Santy, 24, avenue Paul-Santy, 69008 Lyon, France
| | -
- 15 rue Ampère, 92500 Rueil Malmaison, France
| |
Collapse
|
11
|
Tsuji M, Akamatsu Y, Kobayashi H, Mitsugi N, Inaba Y, Saito T. Joint line convergence angle predicts outliers of coronal alignment in navigated open-wedge high tibial osteotomy. Arch Orthop Trauma Surg 2020; 140:707-715. [PMID: 31468134 DOI: 10.1007/s00402-019-03245-0] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/13/2018] [Indexed: 02/02/2023]
Abstract
INTRODUCTION Using a navigation system in open-wedge high tibial osteotomy (OWHTO) has higher accuracy than using the conventional method. However, unintentional over- and under-correction still exist. This study aimed to compare various factors related to over- and under-correction and to assess their predictive factors in the preoperative radiographs. MATERIALS AND METHODS This study involved 96 knees. The difference in the hip-knee-ankle angle (HKA) between the intraoperative navigation system and postoperative radiograph was termed navigation correction loss (NCL). Knees with absolute values of NCL (|NCL|) ≦ 1.5° and |NCL| > 1.5° were categorised into acceptable (n = 46) and outlier (n = 50) groups, respectively. The differences in joint line convergence angle (JLCA) between varus and valgus radiographs, varus JLCA, valgus JLCA, standing JLCA and standing HKA were compared between the two groups. Clinical results were evaluated using the American Knee Society (AKS) scores. RESULTS The mean intraoperative HKA in the navigation system was - 3.8 ± 1.8°, and that in the postoperative standing radiograph was - 4.2 ± 2.5° (p = 0.033). Preoperative varus, valgus and standing JLCA were higher in the outlier group (p = 0.018, p = 0.020 and p = 0.001, respectively). Logistic regression analyses for preoperative factors of |NCL| ≦ 1.5° showed that standing JLCA was a determining factor, with an odds ratio of 1.334 (confidence interval was 1.087-1.637, p = 0.006). AKS score was higher in the acceptable group (p = 0.040) postoperatively. CONCLUSIONS Higher preoperative standing JLCA was the predictive factor of |NCL| > 1.5°. This factor reduced the rates of under- and over-correction and resulted in better AKS score in OWHTO.
Collapse
Affiliation(s)
- Masaki Tsuji
- Department of Orthopaedic Surgery, Yokohama City University School of Medicine, 3-9 Fukuura, Kanazawa-ku, Yokohama, 236-0004, Japan.
| | - Yasushi Akamatsu
- Department of Orthopaedic Surgery, Yokohama City University School of Medicine, 3-9 Fukuura, Kanazawa-ku, Yokohama, 236-0004, Japan
| | - Hideo Kobayashi
- Department of Orthopaedic Surgery, Yokohama City University School of Medicine, 3-9 Fukuura, Kanazawa-ku, Yokohama, 236-0004, Japan
| | - Naoto Mitsugi
- Department of Orthopaedic Surgery, Yokohama City University Medical Center, 4-57 Urahunecho, Minami-ku, Yokohama, Japan
| | - Yutaka Inaba
- Department of Orthopaedic Surgery, Yokohama City University School of Medicine, 3-9 Fukuura, Kanazawa-ku, Yokohama, 236-0004, Japan
| | - Tomoyuki Saito
- Department of Orthopaedic Surgery, Yokohama City University School of Medicine, 3-9 Fukuura, Kanazawa-ku, Yokohama, 236-0004, Japan
| |
Collapse
|
12
|
Ribeiro CH, Mod MSB, Isch D, Baier C, Maderbacher G, Severino NR, Cataneo DC. A novel device for greater precision and safety in open-wedge high tibial osteotomy: cadaveric study. Arch Orthop Trauma Surg 2020; 140:203-208. [PMID: 31707483 DOI: 10.1007/s00402-019-03300-w] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/31/2019] [Indexed: 11/27/2022]
Abstract
INTRODUCTION The complications of the open-wedge osteotomy technique (slope, hypo- and hypercorrection and fractures) are related to difficulties in the control of the open-wedge angle during surgery. MATERIALS AND METHODS In this cadaveric study, we evaluated the safety and precision of a novel system, the Realignment High Control System (RHC), in the correction of knee mechanical axis and slope. The RHC has a fixation plate coupled to a dynamic device that opens the osteotomy continuously, allowing plate fixation before osteotomy wedge opening. RESULTS All procedures were easily performed, with no fractures. The openings equaled the indicated by the navigation system for 7.5° and 10°, and for 5°, there was a statistically, although not clinically significant, difference of 0.6°. The slope shown by the RHC setting and in the navigation system was significantly different for the 10° setting only, with a mean difference of 0.563°. CONCLUSIONS RHC facilitates the surgical technique of high tibial osteotomy, with gradual wedge opening, precise correction of the mechanical axis, and appropriate control of the tibial slope, even with larger openings.
Collapse
Affiliation(s)
- Cristiano Hossri Ribeiro
- Knee Surgery Division, Hospital Orto, Av. Nove de Julho, 1017, Vila Icaraí, São José dos Campos, SP, 12243-690, Brazil.
| | | | | | | | | | - Nilson Roberto Severino
- Department of Orthopedics and Traumatology, Santa Casa de Misericórdia de São Paulo (SCSP), São Paulo, Brazil
| | - Daniele Cristina Cataneo
- Surgery and Orthopaedics Department, Universidade Estadual de São Paulo (Unesp), Botucatu, SP, Brazil
| |
Collapse
|
13
|
Abstract
Osteotomies around the knee for treating osteoarthritis or knee instability are currently well-established procedures. Success of these realignment procedures is based on the accuracy and the reliability of correction angles in the coronal and sagittal alignment. In this context of improving precision and adapting the correction to each patient, navigation is currently being widely used. The rationale for its use is based on understanding the advantages and limitations, technical principles, and potential pitfalls. This article describes these areas and the overall clinical outcomes of this system for knee osteotomies.
Collapse
Affiliation(s)
- Thomas Neri
- Sydney Orthopaedic Research Institute (SORI), Level 1, The Gallery 445 Victoria Avenue, Chatswood, New South Wales 2067, Australia.
| | - Darli Myat
- Sydney Orthopaedic Research Institute (SORI), Level 1, The Gallery 445 Victoria Avenue, Chatswood, New South Wales 2067, Australia
| | - David Parker
- Sydney Orthopaedic Research Institute (SORI), Level 1, The Gallery 445 Victoria Avenue, Chatswood, New South Wales 2067, Australia
| |
Collapse
|
14
|
Kuriyama S, Morimoto N, Shimoto T, Takemoto M, Nakamura S, Nishitani K, Ito H, Matsuda S, Higaki H. Clinical efficacy of preoperative 3D planning for reducing surgical errors during open-wedge high tibial osteotomy. J Orthop Res 2019; 37:898-907. [PMID: 30816588 DOI: 10.1002/jor.24263] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/30/2018] [Accepted: 02/17/2019] [Indexed: 02/04/2023]
Abstract
Increases in posterior tibial slope (PTS) with open-wedge high tibial osteotomy (OWHTO) are often related to two surgical errors: Symmetric opening of the osteotomy gap and a tendency to open the gap from the anteromedial direction. The study objective was to define trends in these two errors using computer simulation and clinical effects of their countermeasures. First, 60 knees with varus deformity were assessed with three-dimensional (3D) planning using computed tomography to allow for the mechanical axis to pass through a point at 62.5% of the width of the tibial plateau, defined as the weight-bearing line percentage (WBL%). Anterior and posterior widths of the opening gap to maintain PTS were measured. The effect on PTS when osteotomy gaps were opened from the anteromedial direction up to 30° was evaluated. Mean anterior width (y) was 6.6 mm (range, 2.2-10.9) and mean posterior width (x) was 9.1 mm (range, 3.9-15.7), which can be expressed as y = 0.75x - 0.24. Opening gaps from the anteromedial direction at 10°, 20°, and 30° led to a mean PTS increase of 1.9°, 3.9°, and 5.6°, respectively. In most cases, WBL% with anteromedial opening at 30° passed through a point at less than 60%. In 47 knees that underwent OWHTO using 3D planning, postoperative coronal and sagittal bone corrections were mostly accurate. However, postoperative WBL% was negatively correlated with correction angle because of difficulties in predicting medial joint tightness. Preoperative 3D planning for OWHTO can reduce surgical errors, but postoperative WBL% remains variable. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res.
Collapse
Affiliation(s)
- Shinichi Kuriyama
- Department of Orthopaedic Surgery, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507, Japan
| | - Naoki Morimoto
- Department of Orthopaedic Surgery, Takashima Municipal Hospital, Shiga, Japan
| | - Takeshi Shimoto
- Faculty of Information Engineering, Department of Information and Systems Engineering, Fukuoka Institute of Technology, Fukuoka, Japan
| | - Mitsuru Takemoto
- Department of Orthopaedic Surgery, Kyoto City Hospital, Kyoto, Japan
| | - Shinichiro Nakamura
- Department of Orthopaedic Surgery, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507, Japan
| | - Kohei Nishitani
- Department of Orthopaedic Surgery, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507, Japan
| | - Hiromu Ito
- Department of Orthopaedic Surgery, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507, Japan
| | - Shuichi Matsuda
- Department of Orthopaedic Surgery, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507, Japan
| | - Hidehiko Higaki
- Faculty of Life Science, Department of Life Science, Kyushu Sangyo University, Fukuoka, Japan
| |
Collapse
|
15
|
Comparison of navigated and conventional high tibial osteotomy for the treatment of osteoarthritic knees with varus deformity: A meta-analysis. Int J Surg 2018; 55:211-219. [PMID: 29555521 DOI: 10.1016/j.ijsu.2018.03.024] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2018] [Accepted: 03/12/2018] [Indexed: 01/11/2023]
Abstract
BACKGROUND High tibial osteotomy (HTO) is a usefully surgical procedure to correct the malalignment and delay the progression of osteoarthritis. It is still controversy whether navigation system can offer more accuracy of targeted alignment and achieve better clinical outcomes than conventional method. The purpose of present meta-analysis was to investigate whether navigation system was superior to conventional method with regard to clinical and radiographic outcomes. METHOD The included studies compared the clinical and radiographic outcomes between navigated HTO group and conventional group. The clinical assessments were Lysholm Score, AKS Function Score and Arc of motion, and the radiographic outcomes were Mechanical axis (MA), Weight bearing line ratio (WBL), Outliers of alignment and Change in TPS used to evaluate alignment correction. The meta-analysis was performed using Review Manager 5.3 software. Downs and Black and the Newcastle-Ottawa Scale (NOS) were used to evaluate the study quality. RESULT Sixteen studies were eligible in present meta-analysis, including thirteen studies concerning opening wedge HTO and three studies involving closing wedge HTO. Clinical outcomes were only reported in studies which used opening wedge HTO. No significant differences were observed in all clinical outcomes between navigated and conventional HTO. Regarding radiographic outcomes, no significant difference in WBL ratio was observed between navigated and conventional HTO. Patients undergoing navigated HTO were associated with significantly greater in MA and lower in Outliers of alignment compared with those undergoing conventional HTO. Compared with conventional HTO, increase in TPS was significantly lower in navigated HTO group using opening wedge HTO, but decrease in TPS was significantly greater in navigated HTO group using closing wedge HTO. CONCLUSION Our meta-analysis demonstrated that navigated HTO offered more accuracy and precision of alignment correction, except WBL ratio. However, better clinical outcomes were not observed in navigation group.
Collapse
|
16
|
Webb M, Dewan V, Elson D. Functional results following high tibial osteotomy: a review of the literature. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY 2018; 28:555-563. [PMID: 29302782 PMCID: PMC5906498 DOI: 10.1007/s00590-017-2112-8] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/20/2017] [Accepted: 12/13/2017] [Indexed: 02/06/2023]
Abstract
Introduction High tibial osteotomy (HTO) is an operation used to treat patients with medial compartment knee osteoarthritis. The United Kingdom Knee Osteotomy Registry (UKKOR) has been set up to gather contemporaneous data on HTO throughout the patient journey. UKKOR uses a variety of patient-reported outcome measures (PROMs) to gauge the surgical outcome. Aim The aim of this review is to analyse the published literature that has used PROMs to assess the outcomes following HTO. Methodology Two searches of the literature were performed and compiled highlighting 95 articles of interest. After screening and manual additions, 23 manuscripts were reviewed and appraised using the appropriate Critical Appraisal Skills Programme Checklist (Kai et al. in PLoS Med 4(11):1766–1775, 2007). Results and discussion There is a variety of published literature on HTO with a varied approach to the use of PROMs. Their use has increased recently, and studies have demonstrated that they are appropriate assessment tools for monitoring outcomes following HTO. In all of the studies that compared pre-operative to post-operative PROMs, there have been significant improvements. However, the data are varied due to differing study designs which in some instances have significant limitations. Conclusion PROMs are effective ways to measure outcomes following HTO. They can also be useful in predicting outcome. The heterogeneity of the data and limitations of the study designs limit the transferability of the data. It is therefore important to analyse data from a multi-surgeon, multi-centre source that uses robust and constant pre- and post-operative PROMs.
Collapse
Affiliation(s)
- Mark Webb
- Northern Deanery, Waterfront 4, Goldcrest Way, Newburn Riverside, Newcastle upon Tyne, NE15 8NY UK
| | - Varun Dewan
- Royal Wolverhampton NHS Trust, Wolverhampton Road, Heath Town, Wolverhampton, WV10 0QP UK
| | - David Elson
- Queen Elizabeth Hospital, Gateshead, NE9 6SX UK
| |
Collapse
|
17
|
Effect of Computer Navigation on Accuracy and Reliability of Limb Alignment Correction following Open-Wedge High Tibial Osteotomy: A Meta-Analysis. BIOMED RESEARCH INTERNATIONAL 2017; 2017:3803457. [PMID: 29130040 PMCID: PMC5654296 DOI: 10.1155/2017/3803457] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/09/2017] [Accepted: 09/06/2017] [Indexed: 11/18/2022]
Abstract
Background It is unclear whether computer navigation can improve the accuracy and reliability of targeted lower limb alignment correction following open-wedge high tibial osteotomy (HTO). This meta-analysis was designed to compare the accuracy and reliability of limb alignment correction between computer navigated and conventional open-wedge HTOs. Methods Studies that compared postoperative coronal alignment, including mechanical axis (MA) and weight bearing line (WBL) ratio, outliers of alignment correction, and change in tibial posterior slope, following open-wedge HTO performed using computer navigated and conventional methods were included. Results Ten studies were included in the meta-analysis. The MA (0.93°; 95% confidence interval [CI]: 0.45–1.41°; P < 0.001) and WBL ratio (1.5%; 95% CI: 0.03–2.98%; P = 0.048) were significantly greater for computer navigated HTO than for conventional HTO. Outliers of alignment correction after surgery were significantly lower in patients who underwent computer navigated HTO than in those who underwent conventional HTO (odds ratio: 0.25; 95% CI: 0.08–0.79; P = 0.02). Changes in posterior tibial slope from before to after surgery, however, were similar for the two approaches. Conclusion Computer navigated HTO resulted in slightly more valgus postoperative alignment and effectively reduced outliers of alignment correction but had no effect on change in posterior tibial slope when compared with conventional HTO.
Collapse
|
18
|
Chang J, Scallon G, Beckert M, Zavala J, Bollier M, Wolf B, Albright J. Comparing the accuracy of high tibial osteotomies between computer navigation and conventional methods. Comput Assist Surg (Abingdon) 2017; 22:1-8. [PMID: 27981853 PMCID: PMC6262829 DOI: 10.1080/24699322.2016.1271909] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022] Open
Abstract
BACKGROUND The accuracy of correction has been shown to be an important determinant in long-term outcomes of patients who were treated with a medial open-wedge high tibial osteotomy (HTO) who suffer from unicompartmental osteoarthritis (OA). Computer navigation systems have the potential to improve surgical precision. The purpose of this study was to compare radiographic outcomes between patients treated with a navigation system and those treated through conventional methods of assessing alignment intra-operatively. The null hypothesis was that the method of assessing the alignment intra-operatively would make no difference in the accuracy of correction. METHODS In this retrospective study, 107 patients with medial varus OA who were managed by open-wedge HTO were included. Of the 107 patients, 41 were treated using an intraoperative navigation system and 66 were treated using conventional methods. Pre-operative and post-operative single-leg, long-leg standing alignment films were used to determine the extent of pre-operative varus deformity and the post-surgical correction achieved compared to the predetermined target range. RESULTS The navigational system had eight instances of software malfunction (19.5%) intra-operatively and correction was determined using the cable method. These results were analyzed as part of the conventional group. Post-operative radiographic differences were significant between the two groups. In the navigation group, 75.8% of the patients were corrected within the target range compared to 66.2% in the conventional group. More patients were also under corrected (to the point of remaining in varus) using conventional methods compared to a navigation system. There was no statistically significant difference in the degree of correction in the sagittal plane between the two groups. Regardless of the method used for checking alignment intra-operatively, there was a statistically significant difference in post-operative weight-bearing measurements when the surgeon had intra-operative axial loading versus when they did not. CONCLUSION For coronal plane corrections, the navigation system was shown to have greater success in achieving the desired correction value and in having fewer patients who were under corrected. Despite the measurement technique a surgeon chooses to assess the accuracy of correction, axial loading the extremity in order to simulate the weight-bearing film alignment post-operatively is important to maximize the accuracy of correction needed.
Collapse
Affiliation(s)
- Justin Chang
- a University of Iowa Roy J and Lucille A Carver College of Medicine , Department of Orthopedics and Rehabilitation , Iowa City , IA , USA
| | - Greg Scallon
- b University of Minnesota Twin Cities , Department of Orthopedic Surgery , Minneapolis , MN , USA
| | - Mitch Beckert
- a University of Iowa Roy J and Lucille A Carver College of Medicine , Department of Orthopedics and Rehabilitation , Iowa City , IA , USA
| | - Jeff Zavala
- a University of Iowa Roy J and Lucille A Carver College of Medicine , Department of Orthopedics and Rehabilitation , Iowa City , IA , USA
| | - Matthew Bollier
- c University of Iowa Hospitals and Clinics , Department of Orthopedics and Rehabilitation , Iowa City , IA , USA
| | - Brian Wolf
- c University of Iowa Hospitals and Clinics , Department of Orthopedics and Rehabilitation , Iowa City , IA , USA
| | - John Albright
- c University of Iowa Hospitals and Clinics , Department of Orthopedics and Rehabilitation , Iowa City , IA , USA
| |
Collapse
|
19
|
Kochergin PG, Kornilov NN, Kulyaba TA. THE INFLUENCE OF COMPUTER-ASSISTED SURGERY ON CLINICAL AND RADIOGRAPHIC OUTCOMES OF PERIАRTICULAR FEMUR AND TIBIA OSTEOTOMIES IN OSTEOARTHRITIC PATIENTS (REVIEW). TRAUMATOLOGY AND ORTHOPEDICS OF RUSSIA 2017. [DOI: 10.21823/2311-2905-2017-23-1-163-175] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/01/2022]
|
20
|
Song SJ, Bae DK. Computer-Assisted Navigation in High Tibial Osteotomy. Clin Orthop Surg 2016; 8:349-357. [PMID: 27904715 PMCID: PMC5114245 DOI: 10.4055/cios.2016.8.4.349] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/18/2016] [Accepted: 04/18/2016] [Indexed: 11/25/2022] Open
Abstract
Computer-assisted navigation is used to improve the accuracy and precision of correction angles during high tibial osteotomy. Most studies have reported that this technique reduces the outliers of coronal alignment and unintended changes in the tibial posterior slope angle. However, more sophisticated studies are necessary to determine whether the technique will improve the clinical results and long-term survival rates. Knowledge of the navigation technology, surgical techniques and potential pitfalls, the clinical results of previous studies, and understanding of the advantages and limitations of the computer-assisted navigation are crucial to successful application of this new technique in high tibial osteotomy. Herein, we review the evidence concerning this technique from previous studies.
Collapse
Affiliation(s)
- Sang Jun Song
- Department of Orthopaedic Surgery, Kyung Hee University College of Medicine, Seoul, Korea
| | - Dae Kyung Bae
- Department of Orthopaedic Surgery, Kyung Hee University College of Medicine, Seoul, Korea
| |
Collapse
|
21
|
Outcome reporting following navigated high tibial osteotomy of the knee: a systematic review. Knee Surg Sports Traumatol Arthrosc 2016; 24:3529-3555. [PMID: 27665094 DOI: 10.1007/s00167-016-4327-3] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/11/2016] [Accepted: 09/12/2016] [Indexed: 12/27/2022]
Abstract
PURPOSE This systematic review evaluates radiographic and clinical outcome reporting following navigated high tibial osteotomy (HTO). Conventional HTO was used as a control to compare outcomes and furthermore investigate the quality of evidence in studies reporting outcomes for navigated HTO. It was hypothesized that navigated HTO will show superior clinical and radiographic outcomes compared to conventional HTO. METHODS Two independent reviewers searched PubMed, Ovid (MEDLINE), EMBASE, and Cochrane databases for studies reporting outcomes following navigated HTO. Titles, abstracts, and full-text were screened in duplicate using an a priori inclusion and exclusion criteria. Descriptive statistics were calculated using Minitab ® statistical software. Methodological Index for Nonrandomized Studies (MINORS) and Cochrane Risk of Bias Scores were used to evaluate methodological quality. RESULTS Thirty-four studies which involved 2216 HTOs were analysed in this review, 1608 (72.6 %) navigated HTOs and 608 (27.4 %) conventional HTOs. The majority of studies were of level IV evidence (16). Clinical outcomes were reported in knee and function scores or range of motion comparisons. Postoperative clinical and functional scores were improved by navigated HTO although it is not demonstrated if there is significant improvement compared to conventional HTO. Most common clinical outcome score reported was Lysholm scores (6) which report postoperative scores of 87.8 (standard deviation 5.9) and 88.8 (standard deviation 5.9) for conventional and navigation-assisted HTO, respectively. Radiographic outcomes reported commonly were weight-bearing mechanical axis, coronal plane angle, and posterior tibial slope angle in the sagittal plane. Studies have shown HTO gives significant correction of mechanical alignment and navigated HTO produces significantly less change in posterior tibial slope postoperatively compared to conventional. The mean MINORS for the 17 non-comparative studies was 9/16, and 15/24 for the 14 non-randomized comparative studies. CONCLUSION Navigation HTO results in improved mechanical axis alignment and demonstrates significantly better control over the tibial slope angle change postoperatively compared to conventional methods; however, these improvements have not yet been reflected in clinical outcome scores. Overall the studies report HTO does create significantly improved knee scores and functions compared to patients' preoperative ratings regardless of technique. Future studies on HTO outcomes need to focus on consistency of outcome reporting. LEVEL OF EVIDENCE IV.
Collapse
|
22
|
Surgical accuracy in high tibial osteotomy: coronal equivalence of computer navigation and gap measurement. Knee Surg Sports Traumatol Arthrosc 2016; 24:3410-3417. [PMID: 26801783 DOI: 10.1007/s00167-016-3983-7] [Citation(s) in RCA: 55] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/23/2015] [Accepted: 01/05/2016] [Indexed: 01/30/2023]
Abstract
PURPOSE Medial opening wedge high tibial osteotomy (MOW HTO) is now a successful operation with a range of indications, requiring an individualised approach to the choice of intended correction. This manuscript introduces the concept of surgical accuracy as the absolute deviation of the achieved correction from the intended correction, where small values represent greater accuracy. Surgical accuracy is compared in a randomised controlled trial (RCT) between gap measurement and computer navigation groups. METHODS This was a prospective RCT conducted over 3 years of 120 consecutive patients with varus malalignment and medial compartment osteoarthritis, who underwent MOW HTO. All procedures were planned with digital software. Patients were randomly assigned into gap measurement or computer navigation groups. Coronal plane alignment was judged using the mechanical tibiofemoral angle (mTFA), before and after surgery. Absolute (positive) values were calculated for surgical accuracy in each individual case. RESULTS There was no significant difference in the mean intended correction between groups. The achieved mTFA revealed a small under-correction in both groups. This was attributed to a failure to account for saw blade thickness (gap measurement) and over-compensation for weight bearing (computer navigation). Surgical accuracy was 1.7° ± 1.2° (gap measurement) compared to 2.1° ± 1.4° (computer navigation) without statistical significance. The difference in tibial slope increases of 2.7° ± 3.9° (gap measurement) and 2.1° ± 3.9° (computer navigation) had statistical significance (P < 0.001) but magnitude (0.6°) without clinical relevance. CONCLUSION Surgical accuracy as described here is a new way to judge achieved alignment following knee osteotomy for individual cases. This work is clinically relevant because coronal surgical accuracy was not superior in either group. Therefore, the increased expense and surgical time associated with navigated MOW HTO is not supported, because meticulously conducted gap measurement yields equivalent surgical accuracy. LEVEL OF EVIDENCE I.
Collapse
|
23
|
Akamatsu Y, Kobayashi H, Kusayama Y, Kumagai K, Saito T. Comparative Study of Opening-Wedge High Tibial Osteotomy With and Without a Combined Computed Tomography-Based and Image-Free Navigation System. Arthroscopy 2016; 32:2072-2081. [PMID: 27160461 DOI: 10.1016/j.arthro.2016.02.018] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/09/2015] [Revised: 02/03/2016] [Accepted: 02/04/2016] [Indexed: 02/02/2023]
Abstract
PURPOSE To assess whether a combined computed tomography (CT)-based and image-free navigation system results in better coronal and sagittal alignment than the conventional method for performing opening-wedge high tibial osteotomy (OWHTO) and whether CT-based navigation results in acquisition of an accurate osteotomy plane. METHODS Sixty-two consecutive knees were randomly divided into navigated and conventional groups. The intraoperative correction angle was determined by the change in hip-knee-ankle angle in the navigated group and by the predicted medial opening width in the conventional group. Outliers of femorotibial angle (FTA) and tibial posterior slope (TPS) were defined as angles of >175° or <165° and angles of >2.5° or <-2.5°, respectively. Radiographic and clinical data were compared between the 2 groups at 2 years postoperatively. RESULTS Mean postoperative FTAs were 168.5° in the navigated group and 168.1° in the conventional group. Mean change in TPS of -0.2° in the navigated group was significantly lower than that of 1.6° in the conventional group (P = .005). On postoperative CT, mean angle between the tibial plateau and osteotomy planes in the sagittal plane showed a significantly higher anterior opening of 12° in the conventional than in the navigated group (P < .001). There was a significantly greater proportion of TPS outliers in the conventional (51.6%) than in the navigated group (12.9%) (P = .001), and a significantly greater proportion within the normal range in both planes in the navigated (74.2%) than in the conventional group (48.4%) (P = .037). CONCLUSIONS Combined CT-based and image-free navigation in OWHTO better preserves the original TPS and more frequently restores normal coronal and sagittal plane knee joint alignment. CT-based navigation also enabled acquisition of our target osteotomy plane in the sagittal plan. The navigation system in OWHTO was helpful for simultaneous control of the alignment in 2 planes. LEVEL OF EVIDENCE Level II, lesser-quality prospective randomized trial.
Collapse
Affiliation(s)
- Yasushi Akamatsu
- Department of Orthopaedic Surgery, Yokohama City University School of Medicine, Yokohama, Japan.
| | - Hideo Kobayashi
- Department of Orthopaedic Surgery, Yokohama City University School of Medicine, Yokohama, Japan
| | - Yoshihiro Kusayama
- Department of Orthopaedic Surgery, Yokohama City University School of Medicine, Yokohama, Japan
| | - Ken Kumagai
- Department of Orthopaedic Surgery, Yokohama City University School of Medicine, Yokohama, Japan
| | - Tomoyuki Saito
- Department of Orthopaedic Surgery, Yokohama City University School of Medicine, Yokohama, Japan
| |
Collapse
|
24
|
Kim HJ, Yoon JR, Choi GW, Yang JH. Imageless Navigation Versus Conventional Open Wedge High Tibial Osteotomy: A Meta-Analysis of Comparative Studies. Knee Surg Relat Res 2016; 28:16-26. [PMID: 26955609 PMCID: PMC4779801 DOI: 10.5792/ksrr.2016.28.1.16] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/22/2015] [Revised: 06/25/2015] [Accepted: 06/28/2015] [Indexed: 12/27/2022] Open
Abstract
Purpose To summarize and compare radiological and clinical outcomes of open wedge high tibial osteotomy (HTO) using imageless computer-assisted navigation with conventional HTO. Methods A literature search of online register databases was conducted. The risk ratio (RR) of radiological outliers and mean differences in clinical outcomes were compared between navigated and conventional HTOs. Radiological results were evaluated by subgroup analyses according to the study period (concurrent/consecutive) and the use of locking fixation device. Results Seven comparative studies with a total sample size of 406 knees were included in this review. Radiographically, the mechanical axis [MA] was within the acceptable range (0°–6°) in 83.7% of the navigation HTO group, showing significant difference from 62.1% of the conventional HTO group. Clinically, despite the forest plot demonstrating a general trend of favoring the navigation system, there were not sufficient studies to determine statistical significance in the meta-analysis. None of the subgroup analyses demonstrated significant differences in the RR of MA outliers. Conclusions The present meta-analysis indicates that the use of navigation in open wedge HTO improves the precision of mechanical alignment by decreasing the incidence of outliers; however, the clinical benefit is not conclusive. Additionally, none of the subgroup analyses demonstrated significant difference in the RR of MA outliers.
Collapse
Affiliation(s)
- Hyun Jung Kim
- Department of Preventive Medicine, Korea University College of Medicine, Seoul, Korea
| | - Jung-Ro Yoon
- Department of Orthopaedic Surgery, Veterans Health Service Medical Center, Seoul, Korea
| | - Gi Won Choi
- Department of Orthopaedic Surgery, Veterans Health Service Medical Center, Seoul, Korea
| | - Jae-Hyuk Yang
- Department of Orthopaedic Surgery, Veterans Health Service Medical Center, Seoul, Korea
| |
Collapse
|
25
|
Clinical and radiographic outcomes of medial open-wedge high tibial osteotomy with Anthony-K plate: prospective minimum five year follow-up data. INTERNATIONAL ORTHOPAEDICS 2015. [DOI: 10.1007/s00264-015-2919-z] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
|
26
|
The use of navigation in medial opening wedge high tibial osteotomy can improve tibial slope maintenance and reduce radiation exposure. INTERNATIONAL ORTHOPAEDICS 2015; 40:499-507. [DOI: 10.1007/s00264-015-2880-x] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/15/2015] [Accepted: 05/02/2015] [Indexed: 10/23/2022]
|
27
|
Hasan K, Rahman QA, Zalzal P. Navigation versus conventional high tibial osteotomy: systematic review. SPRINGERPLUS 2015; 4:271. [PMID: 26090318 PMCID: PMC4469593 DOI: 10.1186/s40064-015-1040-5] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/20/2014] [Accepted: 05/13/2015] [Indexed: 11/10/2022]
Abstract
INTRODUCTION One major use for high tibial osteotomy aims at improving alignment in the symptomatic, varus malaligned, medial compartment osteoarthritic knee. The importance of achieving correct alignment is obvious upon considering the increased potential for significant complications with over- or undercorrection in any plane. The aim of this systematic review was to compare navigation and conventional high tibial osteotomy. METHODS This systematic review searched the MEDLINE and EMBASE databases to compare the short-term clinical and radiological outcomes between patients undergoing either conventional or navigated high tibial osteotomy. RESULTS We retrieved 71 articles, which ultimately resulted in 14 eligible studies for inclusion. Though heterogeneity prevented statistical analysis, only one study failed to suggest superiority of navigation over conventional techniques. CONCLUSION Navigated high tibial osteotomy improves accuracy over conventional techniques, though the current best evidence presented herein must be advanced by higher quality studies.
Collapse
Affiliation(s)
- Khaled Hasan
- Department of Orthopedic Surgery, McMaster University, 1280 Main St W, Hamilton, ON L8S 4L8 Canada
| | - Qusai Abdel Rahman
- University of Toronto, 3359 Mississauga Rd, Mississauga, ON L5L 1C6 Canada
| | - Paul Zalzal
- Department of Orthopedic Surgery, McMaster University, 1280 Main St W, Hamilton, ON L8S 4L8 Canada
| |
Collapse
|