1
|
Wear debris in metal-on-metal bearings and modular junctions : What have we learned from the last decades? ORTHOPADIE (HEIDELBERG, GERMANY) 2023; 52:206-213. [PMID: 36820850 DOI: 10.1007/s00132-023-04346-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 01/12/2023] [Indexed: 02/24/2023]
Abstract
Metal-on-metal (MoM) bearing hip arthroplasty saw increasing utilization and peaked in the 1990s and early 2000s. Although the linear and volumetric wear rate for a MoM bearings was lower than its polyethylene counterpart, metal ion particles were found to be approximately 10 × smaller and 500 × higher in quantity compared to polyethylene wear debris. Research into these articulations have demonstrated their relationship to the formation of lymphocyte-mediated adverse local tissue reactions. The work-up for metal particle-associated conditions (metallosis) includes a thorough patient history and physical examination, blood laboratory studies for metal ion concentrations, and advanced imaging studies including magnetic resonance imaging (MRI). The treatment of metallosis and adverse local tissue reactions ranges from close serial observation to extensive debridement and full revision of arthroplasty components, when indicated.
Collapse
|
2
|
Waseem S, Fong DTP, Onsa M, Khan W, Singh S. Dual Mobility Total Hip Replacements in Young Patients- A Systematic Review. Indian J Orthop 2023; 57:203-210. [PMID: 36777127 PMCID: PMC9880113 DOI: 10.1007/s43465-022-00787-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/21/2022] [Accepted: 11/27/2022] [Indexed: 01/04/2023]
Abstract
Background There is little consensus on outcomes of dual Mobility total hip replacement (DM-THR) in younger patients. We performed a systematic review to examine this. Methods A systematic review of all observational studies and randomised controlled trials of patients under 70 with primary DM-THR in MEDLINE, EMBASE, Pubmed, Cochrane was performed according to PRISMA guidelines. Collected data included demographics, revision, dislocation and infection rates and functional scores. Results Twelve papers studying 738 DM-THR in 664 patients were included. The mean patient age was 46.9 years (13.5-69.0), with 319 (48.0%) being female and 419 (52.0%) being male. After an average follow-up of 90.0 months (1-371 months), the revision rate was 12.7% (84 hips), 0 dislocations were reported but 2.5% (15 hips) underwent intra-prosthetic dislocation. 32.1% hip revisions were due to aseptic loosening. Conclusion Limited literature surrounding the use of DM-THR suggests favourable stability but higher revision rates than conventional THR.
Collapse
Affiliation(s)
- Saima Waseem
- Department of Trauma and Orthopaedics, North West Anglia NHS Foundation Trust, Cambridgeshire, UK
| | - Daniel T. P. Fong
- National Centre for Sport and Exercise Medicine, School of Sport, Exercise and Health Sciences, Loughborough University, Loughborough, UK
| | - Mohammed Onsa
- Department of Trauma and Orthopaedics, North West Anglia NHS Foundation Trust, Cambridgeshire, UK
| | - Wasim Khan
- Department of Trauma and Orthopaedics, Addenbrooke’s Hospital, Cambridge, UK
| | - Sarvpreet Singh
- Department of Trauma and Orthopaedics, North West Anglia NHS Foundation Trust, Cambridgeshire, UK
| |
Collapse
|
3
|
Bellova P, Goronzy J, Riedel R, Grothe T, Hartmann A, Günther KP. Dual-Mobility Cups in Primary Total Hip Arthroplasty. ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE 2023; 161:74-84. [PMID: 34500491 DOI: 10.1055/a-1527-7758] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
Dual-mobility cups (DMCs) were introduced in France more than 40 years ago and are increasingly used not only in hip revision but also primary hip arthroplasty. Due to a simulated large-head articulation and increased jumping distance, DMCs can contribute to a high range of motion in the hip joint and reduce the risk of instability. Numerous studies have reported low dislocation rates and high survival rates in the mid-term follow-up. Nevertheless, long-term data, especially on primary hip replacement, remain limited, and the effect of recent designs and material innovations is still unclear. Therefore, primary DMCs are mainly proposed in patients at high risk for dislocation (i.e. pelvitrochanteric insufficiency, compromised spinopelvic mobility, neuromuscular disorders, obesity and femoral neck fractures). Based on a review of recently published studies referring to these indications, the current study discusses the advantages and disadvantages of DMCs.
Collapse
Affiliation(s)
- Petri Bellova
- Orthopaedics, Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, Dresden, Germany
| | - Jens Goronzy
- Orthopaedics, Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, Dresden, Germany
| | - Roman Riedel
- Orthopaedics, Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, Dresden, Germany
| | - Tim Grothe
- Orthopaedics, Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, Dresden, Germany
| | - Albrecht Hartmann
- Orthopaedics, Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, Dresden, Germany
| | - Klaus-Peter Günther
- Orthopaedics, Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, Dresden, Germany
| |
Collapse
|
4
|
Wegrzyn J, Longaray J, Baez R, Herrera L. Which femoral neck for a dual mobility cup? A biomechanical evaluation. INTERNATIONAL ORTHOPAEDICS 2022; 46:1783-1793. [PMID: 35570206 PMCID: PMC9349148 DOI: 10.1007/s00264-022-05415-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/02/2022] [Accepted: 04/24/2022] [Indexed: 11/28/2022]
Abstract
Abstract
Purpose
This study aimed to evaluate polyethylene (PE) damage and wear lesions to the chamfer of mobile components under mobile and fixed femoral neck impingement at the third articulation, and to determine which femoral neck characteristics should be considered with a dual mobility cup to limit those lesions.
Methods
Two femoral neck geometries (cylindrical and quadrangular) with two surface finishing roughness (rough and polished), and two head-to-neck ratios (28- and 22.2-mm diameter femoral heads) were evaluated in a hip simulator testing. For each characteristic, six femoral necks were tested with six dual mobility cups under fixed and mobile femoral neck impingement conditions. Chamfer PE damage and volumetric wear were evaluated and compared for each femoral neck characteristic and impingement condition.
Results
Under mobile impingement condition, femoral neck characteristics did not significantly affect PE damage and wear lesions to the chamfer (p = 0.283 to 0.810). However, under fixed impingement condition, significantly higher PE damage and wear lesions to the chamfer were produced by the quadrangular geometry compared to the cylindrical geometry (p = 0.004 to 0.025). In addition, with the quadrangular geometry, rough surface finishing was demonstrated to increase volumetric wear of the chamfer (p = 0.009). No significant influence of head-to-neck ratio was observed on PE damage and wear lesions to the chamfer (p = 0.244 to 0.714).
Discussion
This biomechanical study emphasized that femoral neck characteristics are critical with dual mobility cup and tend to favor a cylindrical geometry particularly whether fixed impingement at the third articulation occurs.
Collapse
Affiliation(s)
- Julien Wegrzyn
- Department of Orthopedic Surgery, Lausanne University Hospital and University of Lausanne, Avenue Pierre Decker, 4, CH - 1011, Lausanne, Switzerland.
| | | | | | | |
Collapse
|
5
|
Letissier H, Barbier A, Tristan L, Dubrana F, Lefèvre C, Clavé A. Long-term survival of the Lefèvre retentive cup: 12-year follow-up analysis of 466 consecutive cases. Orthop Traumatol Surg Res 2022; 108:103173. [PMID: 34896581 DOI: 10.1016/j.otsr.2021.103173] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/12/2020] [Revised: 02/26/2021] [Accepted: 03/02/2021] [Indexed: 02/03/2023]
Abstract
INTRODUCTION The Lefèvre retentive cup is a salvage solution for total hip replacement at high risk of dislocation. Only a few studies have reported the medium or long-term survival; most often, only a small number of patients were included in these studies. This led us to conduct a retrospective analysis of a large population to determine: 1) the 10-year survival rate after primary or revision arthroplasty, 2) the complication rate. HYPOTHESIS The dislocation rate is<5% for revision arthroplasty and<2% for primary arthroplasty. MATERIAL AND METHODS This single-center retrospective study included 466 consecutive total hip replacements performed with the Lefèvre retentive cup with a 12-year theoretical minimum follow-up (1/1/1998 to 31/8/2006). There were 257 indications for primary arthroplasty and 209 for revision arthroplasty. The cohort had 316 women and the mean age at surgery was 72.9years (30.2-89.9). The mean follow-up was 10.2±5 years (0.1-19.3). A statistical analysis was done based on the Kaplan-Meier survival curves in two subsets of patients: primary and revision surgery. RESULTS At the final review, 264 patients had died because of reasons unrelated to the procedures (mean 7.8±4.7years after the procedure), 48 were lost to follow-up (mean 3.0±3.3years after the procedure), and 39 patients (8%) had undergone acetabular revision of which 12 were for infection (2.5%), 25 were for loosening (5.4%) (5 femoral loosening only) and 2 were for dislocation (0.4%). In all, there were 10/466 dislocations (2.1%) of which 5/257 (1.9%) were in the primary group and 5/209 (2.4%) were in the revision group: 2 had a cup exchange and 8 were reduced by closed procedures. The probability of survival free of mechanical complications at 10years was estimated at 94.8%±1.6% (95% CI: 91.6%-98.0%) for the primary group and 87.8%±2.7% (95% CI: 82.4%-93.2%) for the revision groups (p=0.0017). There were 39 re-operations in the overall cohort: 1/257 (0.4%) for dislocation, 7/257 (2.7%) for aseptic loosening and 3/257 (1.2%) for infection in the primary group, while in the revision group, 1/209 (0.5%) was for dislocation, 18/209 (8.6%) for aseptic loosening and 9/209 (4.3%) for infection. CONCLUSION The Lefèvre retentive cup has good long-term survival with a low mechanical complication rate, both in primary and revision surgery. To us, this implant appears to be a reliable salvage procedure for total hip replacement in patients at high risk for dislocation. LEVEL OF EVIDENCE IV; retrospective study without control group.
Collapse
Affiliation(s)
- Hoel Letissier
- Service de chirurgie orthopédique et traumatologique, CHRU de la cavale blanche, 29200 Brest, France; Laboratoire de traitement de l'information médicale (LaTIM, UMR1101), bâtiment IBRBS, 22, avenue Camille-Desmoulins, 29200 Brest, France.
| | - Aurélien Barbier
- Service de chirurgie orthopédique et traumatologique, CHRU de la cavale blanche, 29200 Brest, France
| | - Ludovic Tristan
- Service de chirurgie irthopédique, clinique du Ter, 5, allée de la clinique du Ter, 56270 Ploemeur, France
| | - Frédéric Dubrana
- Service de chirurgie orthopédique et traumatologique, CHRU de la cavale blanche, 29200 Brest, France
| | - Christian Lefèvre
- Service de chirurgie orthopédique et traumatologique, CHRU de la cavale blanche, 29200 Brest, France; Laboratoire de traitement de l'information médicale (LaTIM, UMR1101), bâtiment IBRBS, 22, avenue Camille-Desmoulins, 29200 Brest, France
| | - Arnaud Clavé
- Laboratoire de traitement de l'information médicale (LaTIM, UMR1101), bâtiment IBRBS, 22, avenue Camille-Desmoulins, 29200 Brest, France; Service de chirurgie orthopédique, polyclinique Saint-George, 2, avenue de Rimiez, 06105 Nice, France
| |
Collapse
|
6
|
Zabaglo M, Merchant H, Haggis P, Middleton RG. Dual mobility hip arthroplasty: iatrogenic intraprosthetic dislocation of a 22 mm head. BMJ Case Rep 2022; 15:e245859. [PMID: 35236674 PMCID: PMC8895908 DOI: 10.1136/bcr-2021-245859] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/20/2022] [Indexed: 11/03/2022] Open
Abstract
We describe the first intraprosthetic dislocations of a 22 mm head in a dual mobility hip replacement in the literature. This case emphasises the importance of information gathering and planning when dealing with arthroplasty complications. Furthermore, it highlights the necessity of adequate muscle relaxation and analgesia when dealing with hip dislocations. A 78-year-old patient presented to the emergency department (ED) with a spontaneous dislocation of her left dual-mobility total hip replacement 3 months after first-stage revision surgery for infection. Reduction via manipulation under analgesia was then attempted in the ED but was ultimately unsuccessful; an iatrogenic intraprosthetic dislocation of the polyethylene liner was sustained. Several factors may have contributed to liner dislocation: a failure to appreciate the implant type, multiple manipulations in ED were attempted under analgesia, but no sedation or muscle relaxation was administered to the patient. The patient subsequently underwent revision surgery.
Collapse
Affiliation(s)
- Mate Zabaglo
- T&O, Royal Cornwall Hospitals NHS Trust, Truro, Cornwall, UK
| | - Haider Merchant
- T&O, Royal Cornwall Hospitals NHS Trust, Truro, Cornwall, UK
| | - Paul Haggis
- T&O, Royal Cornwall Hospitals NHS Trust, Truro, Cornwall, UK
| | | |
Collapse
|
7
|
Lee GC, Kamath A, Courtney PM. Clinical Concerns With Dual Mobility- Should I Avoid it When Possible? J Arthroplasty 2021; 36:S88-S91. [PMID: 33549418 DOI: 10.1016/j.arth.2021.01.006] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/31/2020] [Accepted: 01/05/2021] [Indexed: 02/02/2023] Open
Abstract
The utilization of dual mobility (DM) articulations in total hip arthroplasty (THA) is increasing. The principal appeal of DM implants is its ability to reduce postoperative instability by maximizing the effective ball head size for each reconstruction. However, while DM implants have been used worldwide for over 3 decades, the experience in North America is more limited. Moreover, there remains concerns with intraprosthetic dissociation, wear, metallosis, and soft tissue impingement. Therefore, the purpose of this article is to review the available evidence for these potential issues. First, intraprosthetic dissociation (IPD) is a unique complication of DM implants. Although the rate has decreased with improvements in materials and design, the reported prevalence is approximately 1%. Second, wear in DM implants can be unpredictable and increased wear has been reported in younger, active patients. Third, corrosion in modular DM implants has been described and elevations in serum cobalt and chromium levels have been reported. While the clinical significance of these elevations is unclear, it remains a source of concern with these implants. Finally, psoas impingement and entrapment can be a source of persistent groin pain after THA. DM articulations are a valuable addition to the armamentarium of total hip surgeons. However, these bearings are not free of complications. Consequently, current data only support selective use of DM bearings in patients at increased risk for postoperative instability after arthroplasty.
Collapse
Affiliation(s)
- Gwo-Chin Lee
- Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA
| | - Atul Kamath
- Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, OH
| | - P Maxwell Courtney
- Department of Orthopaedic Surgery, Rothman Orthopaedic Institute, Philadelphia, PA
| |
Collapse
|
8
|
Zhang Z, Xu G, Cao L, Sun W, Zeng X, Xiong N, Wang S, Yu W, Liu Q, Lin H. Dual-Mobility Cup Total Hip Arthroplasty for Displaced Femoral Neck Fractures: A Retrospective Study With a Median Follow-Up of 5 Years. Geriatr Orthop Surg Rehabil 2021; 12:21514593211013244. [PMID: 34017615 PMCID: PMC8114288 DOI: 10.1177/21514593211013244] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/11/2021] [Revised: 03/30/2021] [Accepted: 04/01/2021] [Indexed: 11/24/2022] Open
Abstract
Introduction: Patient outcomes following modern dual-mobility cup total hip arthroplasty (DM-THA) remains a concern. Few reports have focused on the use of modern DM-THA in the setting of Asian populations for displaced osteoporotic femoral neck fractures (FNFs). This study aimed to investigate the outcomes of Chinese population with displaced osteoporotic FNFs initially treated with modern DM-THA. Materials and Methods: Data from 112 consecutive patients (112 hips) with displaced osteoporotic FNFs initially treated with modern DM-THA during 2011-2018 were retrospectively analyzed. Follow-ups were performed at 3 months, 6 months, 12 months, and then every 1 year after surgery. The primary endpoint was the Harris Hip Score (HHS); the secondary endpoint was the main orthopedic complication rate. Results: The mean HHS improved from 58.62 (±15.79) prior to surgery to 86.13 (±9.92) at the final follow-up. The main complication rate was 14.2% (16/112). Sixteen complications in 10 patients were recorded. Of the 16 complications, there were 2 (1.7%) cases requiring revision DM-THA, 3 (2.6%) cases of loosening, 2 (1.7%) cases of migration, 3 (2.6%) intra-prosthetic dislocation (IPD), 4 (3.5%) cases of tilting, and 2 (1.7%) cases of severe wear. The need for revision was attributed to prosthesis loosening associated with poor bony quality. Conclusion: In patients with displaced osteoporotic FNFs, DM-THA may yield favorable functional outcomes and a low rate of main orthopedic complications, in particular, a low dislocation rate.
Collapse
Affiliation(s)
- Zhenfa Zhang
- Department of Rehabilitation Medicine, The First Affiliated Hospital, Sun Yat-sen University, Yuexiu District, Guangzhou China
| | - Guixing Xu
- Department of Neurosurgery, The First Affiliated Hospital, Sun Yat-sen University, Yuexiu District, Guangzhou, China
| | - Lei Cao
- Department of Anaesthesiology, The Central Hospital of Wuhan, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Wei Sun
- Department of Anaesthesiology, The Central Hospital of Wuhan, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Xianshang Zeng
- Department of Orthopaedics, The First Affiliated Hospital, Sun Yat-sen University, Yuexiu District, Guangzhou, China
| | - Nana Xiong
- Department of Orthopaedics, The First Affiliated Hospital, Sun Yat-sen University, Yuexiu District, Guangzhou, China
| | - Shuxin Wang
- Department of Orthopaedics, The First Affiliated Hospital, Sun Yat-sen University, Yuexiu District, Guangzhou, China
| | - Weiguang Yu
- Department of Orthopaedics, The First Affiliated Hospital, Sun Yat-sen University, Yuexiu District, Guangzhou, China
| | - Qilong Liu
- Department of Gastrointestinal Surgery, The First Affiliated Hospital, Sun Yat-sen University, Yuexiu District, Guangzhou, China
| | - Huanyi Lin
- Department of Urinary Surgery, The First Affiliated Hospital, Sun Yat-sen University, Yuexiu District, Guangzhou, China
| |
Collapse
|
9
|
Fontalis A, Epinette JA, Thaler M, Zagra L, Khanduja V, Haddad FS. Advances and innovations in total hip arthroplasty. SICOT J 2021; 7:26. [PMID: 33843582 PMCID: PMC8040589 DOI: 10.1051/sicotj/2021025] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/04/2021] [Accepted: 03/20/2021] [Indexed: 12/12/2022] Open
Abstract
Total hip arthroplasty (THA) has been quoted as one of the most successful and cost-effective procedures in Orthopaedics. The last decade has seen an exponential rise in the number of THAs performed globally and a sharp increase in the percentage of young patients hoping to improve their quality of life and return to physically demanding activities. Hence, it is imperative to review the various applications of technology in total hip arthroplasty for improving outcomes. The development of state-of-the-art robotic technology has enabled more reproducible and accurate acetabular positioning, while long-term data are needed to assess its cost-effectiveness. This opinion piece aims to outline and present the advances and innovations in total hip arthroplasty, from virtual reality and three-dimensional printing to patient-specific instrumentation and dual mobility bearings. This illustrates and reflects the debate that will be at the centre of hip surgery for the next decade.
Collapse
Affiliation(s)
- Andreas Fontalis
- Department of Trauma and Orthopaedic Surgery, University College London Hospitals, London NW1 2BU, UK
| | | | - Martin Thaler
- Department of Orthopaedics and Traumatology, Medical University Innsbruck, Anichstraße 35, 6020 Innsbruck, Austria
| | - Luigi Zagra
- IRCCS Istituto Ortopedico Galeazzi, Hip Department, Milan 20161, Italy
| | - Vikas Khanduja
- Young Adult Hip Service, Department of Trauma and Orthopaedics, Box 37, Addenbrookes Hospital, Cambridge CB2 0QQ, UK
| | - Fares S Haddad
- Department of Trauma and Orthopaedic Surgery, University College London Hospitals, London NW1 2BU, UK
| |
Collapse
|
10
|
Vajapey SP, Fideler KL, Lynch D, Li M. Use of dual mobility components in total hip arthroplasty: Indications and outcomes. J Clin Orthop Trauma 2020; 11:S760-S765. [PMID: 32999552 PMCID: PMC7503159 DOI: 10.1016/j.jcot.2020.07.035] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/26/2020] [Revised: 07/26/2020] [Accepted: 07/30/2020] [Indexed: 12/23/2022] Open
Abstract
Instability after total hip arthroplasty (THA) can be a problematic complication and remains one of the leading causes of revision surgery in the early post-operative period. Dual mobility (DM) implants decrease dislocation risk after THA but they come with their own set of complications. Selective use of DM implants for THA in high risk groups can confer the advantages of this construct while mitigating the risks. In this paper, we review the current literature to examine the evidence for or against use of DM implants in various clinical scenarios and provide an algorithm for when to consider using DM design construct in THA.
Collapse
Affiliation(s)
- Sravya P. Vajapey
- Department of Orthopaedics, The Ohio State University Wexner Medical Center, United States
| | - Kathryn L. Fideler
- Department of Orthopaedics, The Ohio State University Wexner Medical Center, United States
| | - Daniel Lynch
- School of Medicine, The Ohio State University Wexner Medical Center, United States
| | - Mengnai Li
- Department of Orthopaedics, The Ohio State University Wexner Medical Center, United States,Corresponding author. Adult Reconstructive Surgery, Department of Orthopaedics, Ohio State University Wexner Medical Center, 725 Prior Hall Columbus, Ohio, 43210, United States.
| |
Collapse
|
11
|
Jonker RC, van Beers LWAH, van der Wal BCH, Vogely HC, Parratte S, Castelein RM, Poolman RW. Can dual mobility cups prevent dislocation without increasing revision rates in primary total hip arthroplasty? A systematic review. Orthop Traumatol Surg Res 2020; 106:509-517. [PMID: 32278733 DOI: 10.1016/j.otsr.2019.12.019] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/16/2019] [Revised: 12/22/2019] [Accepted: 12/29/2019] [Indexed: 02/03/2023]
Abstract
BACKGROUND Dislocation is one of the leading causes for early revision surgery after total hip arthroplasty (THA). To address this problem, the dual mobility (DM) cup was developed in the 1970s by the French. Despite the increased and, in some countries, broad use of DM cups, high quality evidence of their effectiveness compared to traditional unipolar (UP) cups is lacking. There are a few well-conducted literature reviews, but the level of evidence of the included studies was moderate to low and the rates of revision were not specifically investigated. Therefore, we did a systematic review to investigate whether there is a difference in the rate of dislocations and revisions after primary THA with a DM cup or a UP cup. METHODS We conducted a systematic literature search in PubMed, Embase and Cochrane databases in July 2019. The articles were selected based upon their quality, relevance and measurement of the predictive factor. We used the MINORS criteria to determine the methodological quality of all studies. RESULTS The initial search resulted in 702 citations. After application of the inclusion and exclusion criteria, eight articles met our eligibility criteria and were graded. Included studies were of medium to low methodological quality with a mean score of 14/24 (11-16) points following the MINORS criteria. In the case-control studies, a total of 549 DM cups and 649 UP cups were included. In the registry studies, a total of 5.935 DM cups and 217.362 UP cups were included. In the case-control studies, one (0.2%) dislocation was reported for the DM cups and 46 (7.1%) for the UP cup (p=0.009, IQR=0.00-7.00). Nine (1.6%) revisions, of which zero due to dislocation, were reported for the DM cup and 39 (6.0%), of which 30 due to dislocation, for the UP cup (p=0.046, CI=-16.93-5.73). In the registry studies 161 (2.7%) revisions were reported for the DM cup, of which 14 (8.7%) due to dislocation. For the UP cup, 3.332 (1.5%) revisions were reported (p=0.275, IQR=41.00-866.25), of which 1.093 (32.8%) due to dislocation (p=0.050, IQR=3.50-293.25). CONCLUSION This review suggests lower rates of dislocation and lower rates of revision for dislocation in favor of the DM cups. Concluding, DM cups might be an effective solution to reduce dislocation in primary THA. To evaluate the efficacy of DM cups compared to UP cups, an economic evaluation alongside a randomized controlled trial is needed focusing on patient important endpoints. LEVEL OF EVIDENCE III, systematic review of level III studies.
Collapse
Affiliation(s)
- Ragna C Jonker
- Department of Orthopaedic Surgery, University Medical Center Utrecht, PO Box 85500, 3508 GA Utrecht, The Netherlands.
| | - Loes W A H van Beers
- Department of Orthopaedic Surgery, OLVG, PO Box 95500, 1090 HM Amsterdam, The Netherlands
| | - Bart C H van der Wal
- Department of Orthopaedic Surgery, University Medical Center Utrecht, PO Box 85500, 3508 GA Utrecht, The Netherlands
| | - H Charles Vogely
- Department of Orthopaedic Surgery, University Medical Center Utrecht, PO Box 85500, 3508 GA Utrecht, The Netherlands
| | - Sebastien Parratte
- Department of Orthopedic Surgery and Traumatology, St. Marguerite Hospital Marseille, 270 Boulevard de Sainte-Marguerite, 13009 Marseille, France
| | - René M Castelein
- Department of Orthopaedic Surgery, University Medical Center Utrecht, PO Box 85500, 3508 GA Utrecht, The Netherlands
| | - Rudolf W Poolman
- Department of Orthopaedic Surgery, OLVG, PO Box 95500, 1090 HM Amsterdam, The Netherlands; Department of Orthopaedic Surgery, Leiden University Medical Center, PO Box 9600, 2300 RC Leiden, The Netherlands
| |
Collapse
|
12
|
Nessler JM, Malkani AL, Sachdeva S, Nessler JP, Westrich G, Harwin SF, Mayman D, Jerabek S. Use of dual mobility cups in patients undergoing primary total hip arthroplasty with prior lumbar spine fusion. INTERNATIONAL ORTHOPAEDICS 2020; 44:857-862. [PMID: 32077995 DOI: 10.1007/s00264-020-04507-y] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/10/2020] [Accepted: 02/07/2020] [Indexed: 12/22/2022]
Abstract
BACKGROUND Patients undergoing primary total hip arthroplasty (THA) with prior lumbar spine fusion (LSF) are a high-risk group for instability with reported incidence of dislocation as high as 8.3% using fixed bearing femoral heads. Purpose of this study was to determine risk of post-operative instability in patients undergoing primary THA with a history of prior LSF using dual mobility acetabular cups. METHODS This was a multicenter retrospective study with 93 patients undergoing primary THA using a dual mobility cup with a prior history of instrumented LSF. There were 56 females and 47 males with an average age of 66 years (46-87) and average BMI of 30 with mean follow-up of 2.7 years (range 12-124 months). Surgical approach included posterior (63), direct lateral (15), anterior (11), and direct superior (4). Forty-four percent had one level lumbar fusion, 29% with two levels, and 15% with three or more levels fused. The primary outcome investigated was instability. RESULTS There were no cases of instability or prosthetic joint infection in this group of patients with prior lumbar spine fusion undergoing primary THA using a dual mobility cup. There was one intra-operative periprosthetic femur fracture and one case of aseptic acetabular cup loosening. CONCLUSION Patients undergoing THA with prior LSF are at increased risk for instability due to loss of normal spinopelvic relationship. The use of dual mobility cups in patients with prior LSF undergoing primary THA appears promising with no cases of instability in this high-risk group of patients.
Collapse
Affiliation(s)
- Joseph M Nessler
- University of Wisconsin, 600 Highland Ave, Madison, WI, 53792, USA
| | - Arthur L Malkani
- Adult Reconstruction Program, University of Louisville, 550 South Jackson Street, Louisville, KY, 40202, USA.
| | - Shikha Sachdeva
- Department of Orthopaedic Surgery, University of Louisville, 550 South Jackson Street, Louisville, KY, 40202, USA
| | - Joseph P Nessler
- St. Cloud Orthopedics, 1901 Connecticut Ave S, Sartell, MN, 56377, USA
| | - Geoff Westrich
- Hospital for Special Surgery, 535 E 70th St, New York, NY, 10021, USA
| | - Steven F Harwin
- Icahn School of Medicine at Mount Sinai, 1 Gustave L. Levy Place, New York, NY, 10029-5674, USA
| | - David Mayman
- Hospital for Special Surgery, 535 E 70th St, New York, NY, 10021, USA
| | - Seth Jerabek
- Hospital for Special Surgery, 535 E 70th St, New York, NY, 10021, USA
| |
Collapse
|
13
|
Is Isolated Mobile Component Exchange an Option in the Management of Intraprosthetic Dislocation of a Dual Mobility Cup? Clin Orthop Relat Res 2020; 478:279-287. [PMID: 31794492 PMCID: PMC7438138 DOI: 10.1097/corr.0000000000001055] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Intraprosthetic dislocation is a specific complication of dual mobility cups, although it occurs less frequently with the latest generations of implants. Intraprosthetic dislocation is related to long-term polyethylene wear of the mobile component chamfer and retentive area, leading to a snap-out of the femoral head. With the increased use of dual mobility cups, even in younger and active patients, the management of intraprosthetic dislocation should be defined according to its type. However, no previous studies, except for case reports, have described the strategy to manage long-term wear-related intraprosthetic dislocation, particularly when a dual mobility cup is not loose. QUESTIONS/PURPOSES This study aimed to (1) determine the prevalence of intraprosthetic dislocation in this patient population and the macroscopic findings at the time of surgical revision and (2) evaluate whether isolated mobile component exchange could be an option to manage intraprosthetic dislocation occurring with a well-fixed dual mobility cup metal shell. METHODS From January 1991 to December 2009, a continuous series of 5274 THAs with dual mobility cups (4546 patients; 2773 women; mean [range] age 58 years [22-87]; bilateral THA = 728) were prospectively enrolled in our institutional total joint registry. A cementless, hemispherical dual mobility cup was systematically implanted, regardless of the patient's age or indication for THA. At the latest follow-up examination, the registry was queried to isolate each occurrence of intraprosthetic dislocation, which was retrospectively analyzed regarding the patient's demographics, indication for THA, radiographs, intraoperative findings (polyethylene wear and lesion patterns on the mobile component, periarticular metallosis, and implant damage because of intraprosthetic impingement of the femoral neck), management of intraprosthetic dislocation (isolated exchange of the mobile component or revision of the dual mobility cup), and outcome. RESULTS At a mean (range) follow-up duration of 14 years (3-26), 3% of intraprosthetic dislocations (169 of 5274) were reported, with a mean (range) time from THA of 18 years (13-22). Intraprosthetic dislocation occurred predominantly in younger men (mean [range] age at THA, 42 years [22-64] versus 61 years [46-87]; p < 0.001, and sex ratio (male to female, 1:32 [96 male and 73 female] versus 0.62 [1677 male and 2700 female]; p < 0.001) in patients with intraprosthetic dislocation and those without, respectively, but was not influenced by the indication for THA (105 patients with intraprosthetic dislocation who underwent THA for primary hip osteoarthritis and 64 with other diagnoses versus 3146 patients without who underwent THA for primary hip osteoarthritis and 1959 for other diagnoses (p = 0.9)). In all patients with intraprosthetic dislocation, a macroscopic analysis of the explanted mobile component revealed circumferential polyethylene wear and damage to the chamfer and retentive area, with subsequent loss of retaining power for the femoral head. Nine percent of intraprosthetic dislocations (16 of 169 patients with intraprosthetic dislocations) were associated with aseptic loosening of the dual mobility cup and were managed with acetabular revision without recurrence at a mean (range) follow-up duration of 7.5 years (5-11). Ninety-one percent of intraprosthetic dislocations (153 of 169) were pure, related to wear of the mobile component chamfer and retentive area without aseptic loosening of the dual mobility cup, and managed with isolated mobile component exchange. Intraprosthetic dislocation recurred in 6% (nine of 153) at a mean (range) follow-up interval of 3 years (2-4.5). Additionally, severe premature polyethylene wear of the mobile component with loosening of the dual mobility cup occurred in 12% of patients (19 of 153) at a mean (range) follow-up duration of 1.5 years (0.5-3). CONCLUSIONS A failure rate of 18% (28 of 153 patients undergoing isolated mobile component exchange) was reported within 5 years after isolated mobile component exchange to manage intraprosthetic dislocation occurring with a well-fixed dual mobility cup metal shell. The two modes of failure were early recurrence of intraprosthetic dislocation or severe premature metallosis-related polyethylene wear of the mobile component with loosening of the dual mobility cup. Acetabular revision with synovectomy should remain the standard procedure to manage intraprosthetic dislocation, particularly if periarticular metallosis is present. The exception is intraprosthetic dislocation occurring in elderly or frail patients, for whom a conventional acetabular revision procedure would be associated with an unjustified surgical or anesthetic risk. LEVEL OF EVIDENCE Level II, prognostic study.
Collapse
|
14
|
Fessy MH, Jacquot L, Rollier JC, Chouteau J, Ait-Si-Selmi T, Bothorel H, Chatelet JC. Midterm Clinical and Radiographic Outcomes of a Contemporary Monoblock Dual-Mobility Cup in Uncemented Total Hip Arthroplasty. J Arthroplasty 2019; 34:2983-2991. [PMID: 31444020 DOI: 10.1016/j.arth.2019.07.026] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/23/2019] [Revised: 07/09/2019] [Accepted: 07/19/2019] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The efficacy of contemporary monoblock dual-mobility (DM) cups to prevent dislocations in total hip arthroplasty (THA) is well reported, but there is little published data on their mid- to long-term outcomes. The authors aimed at reporting the 10-year survival of a contemporary DM cup as well as its clinical and radiographic outcomes. METHODS From a retrospective consecutive multicentric series of 516 patients (541 hips) that received uncemented THA between June 2007 and June 2010, 6 patients (6 hips) had cup and stem revisions, 5 patients (5 hips) had isolated stem revision, and 2 patients (2 hips) had isolated insert revision. A total of 103 patients (111 hips) died with their original implants, and 41 patients (42 hips) were lost to follow-up. This left 358 patients (375 hips) for clinical assessment at a median follow-up of 8.7 years (range, 6.8-10.5 years), including 279 patients (290 hips) with postoperative radiographs. Implant survival was calculated using the Kaplan-Meier method, and multivariable analyses were performed to determine whether clinical outcomes are associated with patient or surgical factors. RESULTS The 10-year survival considering revision for aseptic loosening as end point was 100% for the cup and 99.2% for the stem. No dislocations were observed, and radiographic assessment revealed 1 acetabular granuloma (0.3%), but no radiolucencies nor fractures. The Harris hip score improved from 49.6 ± 15.5 to 85.2 ± 14.5, and the postoperative Oxford hip score was 19.2 ± 7.6. Multivariable analyses revealed that improvement in Harris hip score increased with cup diameter (beta, 1.28; P = .039). CONCLUSION Our data confirmed satisfactory midterm outcomes of uncemented THA using a contemporary DM cup, with no dislocations nor cup revisions due to aseptic loosening. LEVEL OF EVIDENCE Level IV, retrospective cohort study.
Collapse
Affiliation(s)
- Michel-Henri Fessy
- Hospices Civils de Lyon, Centre Hospitalier Lyon-Sud, Service de Chirurgie Orthopédique et Traumatologique, Pierre-Bénite Cedex, France; IFSTTAR, UMRT_9406, Laboratoire de Biomécanique et Mécanique des Chocs, Bron, France; Artro Group Institute, Lyon, France
| | - Laurent Jacquot
- Artro Group Institute, Lyon, France; Ramsay Générale de Santé, Department of Orthopaedic Surgery, Clinique d'Argonay, Annecy, France
| | - Jean-Charles Rollier
- Artro Group Institute, Lyon, France; Ramsay Générale de Santé, Department of Orthopaedic Surgery, Clinique d'Argonay, Annecy, France
| | - Julien Chouteau
- Artro Group Institute, Lyon, France; Ramsay Générale de Santé, Department of Orthopaedic Surgery, Clinique d'Argonay, Annecy, France
| | - Tarik Ait-Si-Selmi
- Artro Group Institute, Lyon, France; Ramsay Générale de Santé, Hôpital Privé Jean Mermoz, Centre Orthopédique Santy, Lyon, France
| | | | - Jean-Christophe Chatelet
- Artro Group Institute, Lyon, France; Ramsay Générale de Santé, Centre de Chirurgie Orthopédique du Beaujolais, Arnas, France
| |
Collapse
|
15
|
de l'Escalopier N, Dumaine V, Auberger G, Babinet A, Courpied JP, Anract P, Hamadouche M. Dual mobility constructs in revision total hip arthroplasty: survivorship analysis in recurrent dislocation versus other indications at three to twelve-year follow-up. INTERNATIONAL ORTHOPAEDICS 2019; 44:253-260. [PMID: 31758218 DOI: 10.1007/s00264-019-04445-4] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/04/2019] [Accepted: 10/21/2019] [Indexed: 01/15/2023]
Abstract
BACKGROUND The aim of this retrospective study was to evaluate the clinical, radiologic, and survival results of dual mobility (DM) sockets in revision total hip arthroplasty (THA) performed for instability versus revision THAs performed for other reasons. METHODS From a computerized database, we identified 84 revision THAs using a modern DM socket performed in 81 patients with a mean age of 71 years. Indication for revision was recurrent dislocation in 47 hips, and other reasons in the remaining 37 hips. A survivorship analysis according to the actuarial method was carried out on the entire series using revision for any cause, revision for dislocation, and radiological cup loosening revised or not, as the end points. RESULTS Of the 81 patients, twelve died, six were lost to follow-up, eight had been revised, and 55 patients (58 hips) were unrevised and alive at a mean follow-up of 6.4 years. Dislocation occurred in four of the 47 (8.5%) hips for which indication for revision was dislocation versus one of the remaining 37 (2.7%) hips [odds ratio = 3.4 (0.4-31.3), p = 0.07]. According to our criteria, three acetabular components of which one was revised were considered as loosened. When using revision for dislocation as the end-point, the survival rate at seven years was 90.4 ± 5.3% (IC95%, 79.9-100) in the 47 hips for which the indication for revision was dislocation versus 100% in the remaining 37 hips (log-rank, p = 0.5). CONCLUSIONS The current study indicated that DM sockets represent an interesting solution to prevent dislocation in revision THAs at mid-term follow-up.
Collapse
Affiliation(s)
- Nicolas de l'Escalopier
- Clinical Orthopaedics Research Center, Department of Orthopaedic and Reconstructive Surgery, Hôpitaux Universitaires Paris Centre (HUPC), Site Cochin-Port Royal, Assitance Publique-Hôpitaux de Paris (AP-HP), Université Paris 5, 27 Rue du Faubourg St Jacques, 75014, Paris, France.
| | - Valérie Dumaine
- Clinical Orthopaedics Research Center, Department of Orthopaedic and Reconstructive Surgery, Hôpitaux Universitaires Paris Centre (HUPC), Site Cochin-Port Royal, Assitance Publique-Hôpitaux de Paris (AP-HP), Université Paris 5, 27 Rue du Faubourg St Jacques, 75014, Paris, France
| | - Guillaume Auberger
- Clinical Orthopaedics Research Center, Department of Orthopaedic and Reconstructive Surgery, Hôpitaux Universitaires Paris Centre (HUPC), Site Cochin-Port Royal, Assitance Publique-Hôpitaux de Paris (AP-HP), Université Paris 5, 27 Rue du Faubourg St Jacques, 75014, Paris, France
| | - Antoine Babinet
- Clinical Orthopaedics Research Center, Department of Orthopaedic and Reconstructive Surgery, Hôpitaux Universitaires Paris Centre (HUPC), Site Cochin-Port Royal, Assitance Publique-Hôpitaux de Paris (AP-HP), Université Paris 5, 27 Rue du Faubourg St Jacques, 75014, Paris, France
| | - Jean-Pierre Courpied
- Clinical Orthopaedics Research Center, Department of Orthopaedic and Reconstructive Surgery, Hôpitaux Universitaires Paris Centre (HUPC), Site Cochin-Port Royal, Assitance Publique-Hôpitaux de Paris (AP-HP), Université Paris 5, 27 Rue du Faubourg St Jacques, 75014, Paris, France
| | - Philippe Anract
- Clinical Orthopaedics Research Center, Department of Orthopaedic and Reconstructive Surgery, Hôpitaux Universitaires Paris Centre (HUPC), Site Cochin-Port Royal, Assitance Publique-Hôpitaux de Paris (AP-HP), Université Paris 5, 27 Rue du Faubourg St Jacques, 75014, Paris, France
| | - Moussa Hamadouche
- Clinical Orthopaedics Research Center, Department of Orthopaedic and Reconstructive Surgery, Hôpitaux Universitaires Paris Centre (HUPC), Site Cochin-Port Royal, Assitance Publique-Hôpitaux de Paris (AP-HP), Université Paris 5, 27 Rue du Faubourg St Jacques, 75014, Paris, France
| |
Collapse
|
16
|
Oerlemans LNT, Zijlstra WP, Lameijer H, Coolsma CW. Is a hip flip the right trick? Emerg Med J 2019; 37:53-54. [PMID: 31628149 DOI: 10.1136/emermed-2019-208932] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/10/2019] [Indexed: 11/03/2022]
Abstract
Clinical introductionA 68-year-old man, with known spasticity and a total left hip arthroplasty (THA) performed 6 years ago, was brought to our ED after falling down the stairs. Laying on the stretcher, his left leg was internally rotated and in hyperflexion. An X-ray of the left hip was performed. The diagnosis of posterior hip dislocation was made (figure 1). The patient received sedation and analgesia with 75 mg propofol and 9 mg esketamine intravenously, and a closed reduction procedure was attempted using manual flexion, adduction, traction and internal rotation. Unfortunately, the reduction failed.emermed;37/1/53/F1F1F1Figure 1The patient's X-ray. QUESTION: Why is closed reduction not effective in this case?The femoral head is located more cranially expected, due to material failure. The whole THA should be replaced.This is an anterior dislocation. The closed reduction procedure should be performed by using extension, abduction, traction and internal rotation.The femoral head is not reduced centrally in the acetabulum and the closed reduction procedure should be repeated more forcefully.A dual-mobility cup is used and the liner is not in place anymore. Revision surgery is required. For answer see page 2.
Collapse
Affiliation(s)
| | - Wierd P Zijlstra
- Department of Orthopedic Surgery, Medisch Centrum Leeuwarden, Leeuwarden, The Netherlands
| | - Heleen Lameijer
- Department of Emergency Medicine, Medical Center Leeuwarden, Leeuwarden, The Netherlands
| | - Constant W Coolsma
- Department of Emergency Medicine, Medical Center Leeuwarden, Leeuwarden, The Netherlands
| |
Collapse
|
17
|
Pang Y, Zheng X, Pei F, Chen Y, Guo K, Zhao F. A Retrospective Study to Compare the Efficacy and Postoperative Outcome of Total Hip Arthroplasty with Internal Screw Fixation in Patients with Avascular Necrosis of the Femoral Head. Med Sci Monit 2019; 25:3655-3661. [PMID: 31097682 PMCID: PMC6537666 DOI: 10.12659/msm.913393] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
Abstract
Background This retrospective study compared the effects of total hip arthroplasty (THA) and traditional surgery using internal screw fixation for the treatment of avascular necrosis (AVN) of the femoral head. Material/Methods Two hundred and seventy patients with bilateral AVN of the femoral head were admitted for elective surgery, and 176 patients underwent THA (the THA group), and 94 patients underwent closed reduction screw fixation (the traditional surgery group). The Harris hip score (HHS) was used pre-operatively and to evaluate postoperative outcome. Results The mean operation time in the traditional surgery group (82.6±15.6 min) was significantly less compared with the THA group (104.8±14.2 min) (P=0.001). Intraoperative blood loss in the traditional surgery group (219.8±21.6 mL) was significantly less compared with the THA group (339.4±29.4 mL) (P=0.001). After treatment, the mean HHS score of the THA group (76.5±9.2 points) was significantly increased when compared with the traditional surgery group (61.4±10.5 points) (P=0.001). Disease recurrence rate in the THA group was significantly reduced compared with the traditional surgery group (P=0.001). The mean quality of life score of the THA group (85.5±6.4 points) was significantly higher than that of the traditional surgery group (73.4±8.8 points) (P=0.001). Conclusions Compared with closed reduction screw fixation, THA for AVN of the femoral head effectively reduced the length of hospital stay, time to recovery, and achieved an improved clinical outcome.
Collapse
Affiliation(s)
- Yong Pang
- Department of Orthopedics, The Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, China (mainland)
| | - Xin Zheng
- Department of Orthopedics, The Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, China (mainland)
| | - Fang Pei
- Department of Orthopedics, The Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, China (mainland)
| | - Yeshuai Chen
- Department of Orthopedics, The Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, China (mainland)
| | - Kaijin Guo
- Department of Orthopedics, The Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, China (mainland)
| | - Fengchao Zhao
- Department of Orthopedics, The Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, China (mainland)
| |
Collapse
|
18
|
Koper M, Verdijk R, Bos K. Asymptomatic intraprosthetic dual mobility cup dislocation with increased metal ion levels. Arthroplast Today 2019; 5:38-42. [PMID: 31020019 PMCID: PMC6470350 DOI: 10.1016/j.artd.2018.12.001] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/19/2018] [Revised: 12/09/2018] [Accepted: 12/13/2018] [Indexed: 01/18/2023] Open
Abstract
With the increased use of dual-mobility cups (DMCs) in total-and revision hip arthroplasties, surgeons can expect an increase of known and new complications. During routine follow-up, we observed an asymptomatic patient with an intraprosthetic-dislocation (IPD) and elevated levels of serum metal ions (1.8 ppb of cobalt and 28.0 ppb of chromium). Revision surgery was inevitable. Perioperative metallosis and severe wear of the metal shell and metal femoral head supported the IPD. Literature showed that the modularity of the DMC can result in increased serum metal ions, create excessive wear, and possibly affect implant survival. Our case and review of the literature may form an argument not to consider DMC for primary cases. Furthermore, we advise yearly clinical and radiological follow-up and, on indication, metal ion testing for DMCs.
Collapse
Affiliation(s)
- Maarten Koper
- Department of Orthopedics, Erasmus Medical Center, Rotterdam, the Netherlands
| | - Rob Verdijk
- Department of Pathology, Erasmus Medical Center, Rotterdam, the Netherlands
| | - Koen Bos
- Department of Orthopedics, Erasmus Medical Center, Rotterdam, the Netherlands
| |
Collapse
|
19
|
CORR Insights®: Spinal Fusion Is Associated With Changes in Acetabular Orientation and Reductions in Pelvic Mobility. Clin Orthop Relat Res 2019; 477:331-333. [PMID: 30179934 PMCID: PMC6370096 DOI: 10.1097/corr.0000000000000438] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
|
20
|
Neri T, Philippot R, Klasan A, Putnis S, Leie M, Boyer B, Farizon F. Dual mobility acetabular cups for total hip arthroplasty: advantages and drawbacks. Expert Rev Med Devices 2018; 15:835-845. [PMID: 30345834 DOI: 10.1080/17434440.2018.1538781] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
INTRODUCTION The dual mobility cup (DMC) concept was proposed by Professor Gilles Bousquet in 1974. Its' aims were to prevent postoperative dislocation, restore the physiological range of motion of the hip, and reduce the stresses at the interface. Since it was created, this design has been modified multiple times to reduce the complication rate, improve implant survival, and expand the indications. AREAS COVERED The objective of this review is to discuss the advantages and disadvantages of this implant based on its 40-year history and also to propose a range of indications based on published results. This will provide surgeons with a complete overview of DMC. EXPERT COMMENTARY Published studies on DMC confirm the low dislocation rate. Improvements made to DMC overtime have greatly reduced the complications related to wear, such as aseptic loosening and intraprosthetic dislocation (IPD). According to the literature, the indications have expanded and are no longer limited to revision surgery only. Long-term studies are needed before we can draw formal conclusions and consolidate these promising results.
Collapse
Affiliation(s)
- Thomas Neri
- a Department of Orthopaedic Surgery , University Hospital Centre of Saint-Etienne , Saint Etienne , France.,b EA 7424, Inter-university Laboratory of Human Movement Science , University Lyon, University Jean Monnet , Saint Etienne , France.,c Sydney Orthopaedic Research Institute , Sydney , Australia
| | - Remi Philippot
- a Department of Orthopaedic Surgery , University Hospital Centre of Saint-Etienne , Saint Etienne , France.,b EA 7424, Inter-university Laboratory of Human Movement Science , University Lyon, University Jean Monnet , Saint Etienne , France
| | - Antonio Klasan
- c Sydney Orthopaedic Research Institute , Sydney , Australia
| | - Sven Putnis
- c Sydney Orthopaedic Research Institute , Sydney , Australia
| | - Murilo Leie
- c Sydney Orthopaedic Research Institute , Sydney , Australia
| | - Bertrand Boyer
- a Department of Orthopaedic Surgery , University Hospital Centre of Saint-Etienne , Saint Etienne , France.,b EA 7424, Inter-university Laboratory of Human Movement Science , University Lyon, University Jean Monnet , Saint Etienne , France
| | - Frederic Farizon
- a Department of Orthopaedic Surgery , University Hospital Centre of Saint-Etienne , Saint Etienne , France.,b EA 7424, Inter-university Laboratory of Human Movement Science , University Lyon, University Jean Monnet , Saint Etienne , France
| |
Collapse
|
21
|
Neri T, Boyer B, Geringer J, Di Iorio A, Caton JH, PhiIippot R, Farizon F. Intraprosthetic dislocation of dual mobility total hip arthroplasty: still occurring? INTERNATIONAL ORTHOPAEDICS 2018; 43:1097-1105. [PMID: 30027352 DOI: 10.1007/s00264-018-4054-0] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/05/2018] [Accepted: 07/06/2018] [Indexed: 01/23/2023]
Abstract
PURPOSE The objective was to identify predictive factors for intraprosthetic dislocation (IPD) and to understand how improvements in dual mobility cups (DMC) have helped to reduce dramatically the occurrence of this complication. METHODS DM mobile inserts retrieved from 93 hips were divided into three groups: first-generation DMC with IPD ("firstDMC-IPD"), first-generation DMC with over 15 years of implantation without IPD ("firstDMC-noIPD"), and latest-generation DMC ("newDMC"). The predictive factors for IPD based on clinical, prosthetic, radiological and intraoperative characteristics were analysed by multivariate analysis. The surface of each retrieved mobile insert was analysed using three-dimensional CT scan in order to compare their rim wear. RESULTS Three predictive factors for IPD were found: a high BMI, a wide rough stem neck and a large cup size. Wear of the firstDMC-noIPD inserts was significantly less than those of firstDMC-IPD inserts and significantly more than those of newDMC inserts. For the firstDMC-IPD inserts, the rim's outer surface wear was significantly greater than the rim's inner surface wear. CONCLUSIONS IPD is a specific complication related to wear of the DM mobile insert due to failure of the liner's retaining rim, especially from the rim's outer surface. This long-term issue is different to the early traumatic complication, which can happen after an attempt at closed reduction of a DM THA dislocation. Recent modifications in the design and the coating of contemporary DMC and femoral stems, as well as improvements in the mobile insert itself, seem to corroborate our assumptions about the IPD mechanism and contribute to the quasi-disappearance of this complication.
Collapse
Affiliation(s)
- Thomas Neri
- Department of Orthopaedic Surgery, University Hospital Centre of Saint-Etienne, Saint-Etienne, France. .,EA 7424 - Inter-university Laboratory of Human Movement Science, University Lyon - University Jean Monnet, Saint Etienne, France.
| | - Bertrand Boyer
- Department of Orthopaedic Surgery, University Hospital Centre of Saint-Etienne, Saint-Etienne, France.,Ecole des mines de Saint-Etienne, Saint-Etienne, France
| | - Jean Geringer
- Ecole des mines de Saint-Etienne, Saint-Etienne, France
| | - Alexandre Di Iorio
- Department of Orthopaedic Surgery, University Hospital Centre of Saint-Etienne, Saint-Etienne, France
| | - Jacques H Caton
- Institut orthopédique, 103 rue Coste, 69300, Caluire, France
| | - Remi PhiIippot
- Department of Orthopaedic Surgery, University Hospital Centre of Saint-Etienne, Saint-Etienne, France.,EA 7424 - Inter-university Laboratory of Human Movement Science, University Lyon - University Jean Monnet, Saint Etienne, France
| | - Frederic Farizon
- Department of Orthopaedic Surgery, University Hospital Centre of Saint-Etienne, Saint-Etienne, France.,EA 7424 - Inter-university Laboratory of Human Movement Science, University Lyon - University Jean Monnet, Saint Etienne, France
| |
Collapse
|
22
|
Murphy EP, Fenelon C, Russell S, Condon F. Cause of irreducible dislocation of a re-revision THR. BMJ Case Rep 2018; 2018:bcr-2017-223072. [PMID: 29866666 DOI: 10.1136/bcr-2017-223072] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
Instability or recurrent dislocations are a common reason for revision of total hip replacements (THRs). Dual-mobility constructs can help improve stability by increasing the femoral head jump distance. These constructs are used to decrease the risk of re-revision in the setting of recurrent dislocation. This case describes an unusual case of irreducible dislocation of a re-revision THR due to intraprosthetic dislocation. The patient required open reduction and revision of this construct to a tripolar implant. This is important to appreciate from an emergency medicine point of view as repeated attempts at reduction will be fruitless and may result in a femur fracture. This particular type of dislocation is very rare. Perioperative considerations should include early referral to the orthopaedic team for reduction in theatre, and having a low threshold for open reduction. Revision options should be available when bringing a case like this to the operating theatre.
Collapse
Affiliation(s)
| | | | - Shane Russell
- Department of Trauma and Orthopaedics, Limerick University Hospital, Limerick, Ireland
| | - Finbarr Condon
- Department of Trauma and Orthopaedics, Limerick University Hospital, Limerick, Ireland
| |
Collapse
|
23
|
Retrieval evidence of impingement at the third articulation in contemporary dual mobility cups for total hip arthroplasty. INTERNATIONAL ORTHOPAEDICS 2017; 41:2495-2501. [PMID: 28578471 DOI: 10.1007/s00264-017-3523-1] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/15/2017] [Accepted: 05/16/2017] [Indexed: 02/08/2023]
Abstract
PURPOSE We aimed to assess polyethylene liners of retrieved hips of one design of a dual mobility (DM) cup liner and two designs of femoral stems to better understand the role of femoral stem design on polyethylene impingement. METHODS This was a case-control study involving 70 retrieved highly cross-linked polyethylene (X3) liners used with ABGII (n = 35) and Rejuvenate (n = 35) stems (Stryker). All polyethylene liners were assessed for evidence of rim deformation and the damage quantified using metrology methods. RESULTS A total of 80% of polyethylene liners paired with ABGII necks had macroscopic evidence of neck impingement resulting in a raised lip whilst 23% of liners paired with Rejuvenate necks had evidence of a raised lip (p < 0.0001). The height of the raised rims of the DM cups paired with ABGII necks had a median (range) of 139 μm (72-255). The height of the raised rims of the DM cups paired with Rejuvenate necks had a median (range) of 52 μm (45-90) (p < 0.0001). CONCLUSION Our new findings from retrieved dual mobility bearings showed that polyethylene liner rim deformation resulting from impingement with the femoral neck occurs in early in-human function, is circumferential in distribution, and is affected by the stem neck design. We recommend the use of highly polished and non-edged neck designs when used in conjunction with DM cups.
Collapse
|
24
|
Röhner E, Matziolis G. [Use of dual mobility cups for revision hip arthroplasty]. DER ORTHOPADE 2017; 46:114-120. [PMID: 28097416 DOI: 10.1007/s00132-016-3383-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
The dual mobility cup (DMC) is an increasingly important tool not only in primary but also in revision total hip arthroplasty to prevent dislocation and eventually reduce postoperative complication rates. Various studies have shown survival rates with DMCs of up to 100% with an average dislocation rate of less than 1.5% after primary hip arthroplasty and a follow-up of 10 years. In revision surgery, survival rates of up to 99% were reported with dislocation rates between 0 and 10% after an average of 5 years after implantation. This article is intended to provide an overview of the principle and function of DMCs. Furthermore, indications as well as complications are presented.
Collapse
Affiliation(s)
- E Röhner
- Orthopädische Klinik des Universitätsklinikums Jena am Campus Eisenberg, Waldkrankenhaus "Rudolf Elle" GmbH, Klosterlausnitzer Straße 81, 07607, Eisenberg, Deutschland.
| | - G Matziolis
- Orthopädische Klinik des Universitätsklinikums Jena am Campus Eisenberg, Waldkrankenhaus "Rudolf Elle" GmbH, Klosterlausnitzer Straße 81, 07607, Eisenberg, Deutschland
| |
Collapse
|
25
|
Bousquet dual mobility socket for patient under fifty years old. More than twenty year follow-up of one hundred and thirty one hips. INTERNATIONAL ORTHOPAEDICS 2017; 41:589-594. [PMID: 28091769 DOI: 10.1007/s00264-016-3385-y] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/25/2016] [Accepted: 12/19/2016] [Indexed: 10/20/2022]
Abstract
PURPOSE The aim of this study was to analyze dual mobility cup survival rate on young patients under 50 years old at more than 20 years of follow up. METHODS One hundred thirty seven hips with a first generation of dual mobility Bousquet cup (Serf) were included. The mean age at the time of the surgery was 41 years and the mean follow-up was 21.9 years. RESULTS Twenty year follow-up cup survival rate was 77%. No dislocation occurred, 44 hips were revised (including 21 cup aseptic loosenings isolated, 15 Intra Prosthetic Dislocations), seven hips were lost to follow-up, 11 patients died, and 75 hips were still in situ. CONCLUSION First generation dual mobility cup survival on young patient was comparable with literature results. The main complications, cup aseptic loosening and intra prosthetic dislocation, were wear-related. With improvements of the defects of first generation dual mobility, we might expect an even better survival rate with contemporary DM cups.
Collapse
|
26
|
Batailler C, Fary C, Verdier R, Aslanian T, Caton J, Lustig S. The evolution of outcomes and indications for the dual-mobility cup: a systematic review. INTERNATIONAL ORTHOPAEDICS 2016; 41:645-659. [PMID: 28004142 DOI: 10.1007/s00264-016-3377-y] [Citation(s) in RCA: 60] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/05/2016] [Accepted: 12/11/2016] [Indexed: 01/12/2023]
Abstract
PURPOSE Instability following total hip arthroplasty remains a common and disabling complication. The dual mobility cup (DMC) allows a reduction in the dislocation rate. An increasing number of studies have been undertaken to better understand DMC long term outcomes and complications. The goal of this systematic review was to clarify its different uses and outcomes according to the indications. METHODS A comprehensive literature review was performed using the keywords 'dual mobility' and 'tripolar cup' with no limit regarding the year of publication. One hundred seventy six publications were identified. RESULTS Current literature shows that "contemporary" dual mobility cup are a significant indication to manage instability following primary and revision hip arthroplasty. Survivorship at midterm is comparable to other articulations for primary THA, but is more difficult to evaluate in revision. Intra-prosthetic dislocation, wear, and loosening are now uncommon with new generations of DMC. CONCLUSIONS Compared to previous generations of DMC, the current "contemporary" DMC presents a significant improvement. Current literature reveals a tendency to increase the indications but further studies with long term follow up remain important to consolidate these findings.
Collapse
|
27
|
Prudhon JL, Verdier R, Caton JH. Low friction arthroplasty and dual mobility cup: a new gold standard. INTERNATIONAL ORTHOPAEDICS 2016; 41:563-571. [PMID: 27999924 DOI: 10.1007/s00264-016-3375-0] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/22/2016] [Accepted: 12/11/2016] [Indexed: 01/09/2023]
Abstract
INTRODUCTION Low friction arthroplasty (LFA) introduced by Sir John Charnley was the gold standard for many years. Dislocation and infection are the first causes for early revision. Late failures are polyethylene (PE) wear and loosening. Due to dislocation risk we slowly switched to the use of LFA with dual mobility cups (DMC). The purposes of this study are (1) to assess whether our changes have improved outcomes and (2) what is the new gold standard? MATERIAL AND METHODS We selected from an observational registry of 1,091 cases of hybrid Charnley total hip arthroplasty (THA). The acetabular component was either DMC in 455 cases or fixed cup (FC) in 636 cases. RESULTS Three dislocations (0.6%) occurred in the DMC group (none revised). In the FC group 54 dislocated (8.49%) and 20 were recurrent and underwent revision (revision rate 3.14%). In the DMC group, five acetabular and three femoral revisions were performed (revision rate for loosening 1.7%). In the FC group 19 cases underwent acetabular revision, and five cases had femoral component revised (revision rate for loosening 3.7%). DISCUSSION Charnley's LFA has proven over 50 years of excellent survivorship. To decrease dislocation risk, one suggested increasing femoral head diameter. Gilles Bousquet proposed another way, namely, the DMC concept. Dislocation is no longer a critical issue with DMC as demonstrated in our series and main series. DMC in primary THA is still a subject of debate. Mid-term results do not demonstrate a higher rate of wear than LFA. What is the current gold standard? LFA was and is our current gold standard in association with a DMC.
Collapse
Affiliation(s)
- Jean Louis Prudhon
- Centre Osteo-Articulaire, 5 rue des tropiques, 38130, Echirolles, France.
| | - Régis Verdier
- , 175 rue Jacquard, CS 50307 - 69727, Genay Cedex, France
| | - Jacques H Caton
- Clinique Orthopédique, 103 rue Coste, 69300, Caluire, France
| |
Collapse
|
28
|
Falez F, Papalia M, Favetti F, Panegrossi G, Casella F, Mazzotta G. Total hip arthroplasty instability in Italy. INTERNATIONAL ORTHOPAEDICS 2016; 41:635-644. [PMID: 27999925 DOI: 10.1007/s00264-016-3345-6] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/29/2016] [Accepted: 11/09/2016] [Indexed: 01/25/2023]
Abstract
Hip dislocation is a major and common complication of total hip arthroplasty (THA), which appears with an incidence between 0.3% and 10% in primary total hip arthroplasties and up to 28% in revision THA. The hip dislocations can be classified into three groups: early, intermediate and late. Approximately two-thirds of cases can be treated successfully with a non-operative approach. The rest require further surgical intervention. The prerequisite to developing an appropriate treatment strategy is a thorough evaluation to identify the causes of the dislocation. In addition, many factors that contribute to THA dislocation are related to the surgical technique, mainly including component orientation, femoral head diameter, restoration of femoral offset and leg length, cam impingement and condition of the soft tissues. The diagnosis of a dislocated hip is relatively easy because the clinical situation is very typical. Having identified a dislocated hip, the first step is to perform a closed reduction of the implant. After reduction you must perform a computed tomography scan to evaluate the surgical options for treatment of recurrent dislocation that include: revision arthroplasty, modular components exchange, dual-mobility cups, large femoral heads, constrained cups, elimination of impingement and soft tissue procedures. The objective is to avoid further dislocation, a devastating event which is increasing the number of operations on the hip. To obtain this goal is useful to follow an algorithm of treatment, but the best treatment remains prevention.
Collapse
Affiliation(s)
- Francesco Falez
- Orthopaedic and Traumatology Department, S. Spirito Hospital, Lungotevere in Sassia,1, Rome, Italy.
| | - Matteo Papalia
- Orthopaedic and Traumatology Department, Nuova Itor Clinic, Rome, Italy
| | - Fabio Favetti
- Orthopaedic and Traumatology Department, S. Spirito Hospital, Lungotevere in Sassia,1, Rome, Italy
| | - Gabriele Panegrossi
- Orthopaedic and Traumatology Department, S. Spirito Hospital, Lungotevere in Sassia,1, Rome, Italy
| | - Filippo Casella
- Orthopaedic and Traumatology Department, S. Spirito Hospital, Lungotevere in Sassia,1, Rome, Italy
| | - Gianluca Mazzotta
- Orthopaedic and Traumatology Department, S. Spirito Hospital, Lungotevere in Sassia,1, Rome, Italy
| |
Collapse
|
29
|
Wear of dual-mobility cups: a review article. INTERNATIONAL ORTHOPAEDICS 2016; 41:625-633. [DOI: 10.1007/s00264-016-3326-9] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/06/2016] [Accepted: 10/17/2016] [Indexed: 12/26/2022]
|
30
|
Boyer B, Neri T, Geringer J, Di Iorio A, Philippot R, Farizon F. Understanding wear in dual mobility total hip replacement: first generation explant wear patterns. INTERNATIONAL ORTHOPAEDICS 2016; 41:529-533. [PMID: 27928599 DOI: 10.1007/s00264-016-3362-5] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/30/2016] [Accepted: 11/28/2016] [Indexed: 11/27/2022]
Abstract
PURPOSE Dual mobility was introduced by Pr. G. Bousquet to improve the dislocation risk of total hip arthroplasty (THR). The wear mechanisms of this implant remain to be understood. Could enhanced explant wear analysis explain liner wear behaviour? METHODS Sixty-six explanted liners were selected. Non-destructive 3D scanning and heat colour treatment allowed reporting wear patterns on both convex and concave sides of the liners. RESULTS For many liners, liner convexity wear was found to be homogeneous, and linked to a longer implantation time. A few liners had signs of blocking of the convexity, leading to excessive internal damage. Intra prosthetic dislocations were found to only have internal circular wear without liner penetration. CONCLUSION Heat colour treatment showed its effectiveness for highlighting wear patterns. Optimal convexity mobility seemed to be leading to a longer implantation time, with decreased contact stresses on concavity. The retentive rim should have a distinct wear analysis.
Collapse
Affiliation(s)
- Bertrand Boyer
- Mines de Saint-Etienne, Unité SAINBIOSE, INSERM U1059, Université de Lyon-St Etienne, Lyon, France.
- Laboratoire de Physiologie de l'Exercice, Faculté de Médecine J. Lisfranc, Université Jean Monnet, 42055, Cedex 2, France.
| | - Thomas Neri
- Laboratoire de Physiologie de l'Exercice, Faculté de Médecine J. Lisfranc, Université Jean Monnet, 42055, Cedex 2, France
| | - Jean Geringer
- Mines de Saint-Etienne, Unité SAINBIOSE, INSERM U1059, Université de Lyon-St Etienne, Lyon, France
| | - Alexandre Di Iorio
- Laboratoire de Physiologie de l'Exercice, Faculté de Médecine J. Lisfranc, Université Jean Monnet, 42055, Cedex 2, France
| | - Remi Philippot
- Laboratoire de Physiologie de l'Exercice, Faculté de Médecine J. Lisfranc, Université Jean Monnet, 42055, Cedex 2, France
| | - Frederic Farizon
- Laboratoire de Physiologie de l'Exercice, Faculté de Médecine J. Lisfranc, Université Jean Monnet, 42055, Cedex 2, France
| |
Collapse
|
31
|
Hamadouche M, Ropars M, Rodaix C, Musset T, Gaucher F, Biau D, Courpied JP, Huten D. Five to thirteen year results of a cemented dual mobility socket to treat recurrent dislocation. INTERNATIONAL ORTHOPAEDICS 2016; 41:513-519. [PMID: 27889840 DOI: 10.1007/s00264-016-3343-8] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/06/2016] [Accepted: 11/08/2016] [Indexed: 01/23/2023]
Abstract
PURPOSE Dual mobility (DM) socket has been associated with a low rate of dislocation following both primary and revision total hip arthroplasty (THA). However, little is known about the long-term efficiency of DM in the treatment of THA instability. The purpose of this retrospective study was to evaluate the outcome of a cemented DM socket to treat recurrent dislocation after a minimum of five year follow-up. METHODS The series included 51 patients with a mean age of 71.3 ± 11.5 (range, 41-98) years presenting with recurrent dislocation (mean 3.3). A single DM socket design was used consisting of a stainless steel outer shell with grooves with a highly polished inner surface articulating with a mobile polyethylene component. The femoral head was captured in the polyethylene component using a snap-fit type mechanism, the latter acting as a large unconstrained head inside the metal cup. RESULTS At the minimum five year follow-up evaluation, 18 of the 51 patients deceased at a mean of 4.8 ± 2.3 years, three were lost to follow-up at a mean of 1.4 years, seven had been revised at a mean of 4.7 ± 3.1 years (range, 1.5-9.1), and the remaining 23 were still alive and did not have revision at a mean of 8.2 ± 2.4 years (range, 5-13 years). Of the seven revision, three were performed for further episodes of dislocation (at the large bearing for one patient and intra-prosthetic for two patients) after a mean 5.9 ± 2.9 years (range, 2.7-9.1), whereas two were performed for late sepsis and two for aseptic loosening of the acetabular component. Radiographic analysis did not reveal any further loosening on the acetabular side. The survival rate of the cup at ten years, using re-dislocation as the end-point, was 86.1 ± 8.4% (95% confidence interval, 69.7-100%). The survival rate of the cup at ten years, using revision for any reason as the end-point, was 75.2 ± 9.3% (95% confidence interval, 56.9-93.5%). CONCLUSION A cemented dual mobility cup was able to restore hip stability in 94% of patients presenting with recurrent dislocating hips up to 13-year follow-up with none of the complications associated with constrained devices, as mechanical failure occurred in only 3.9% of the patients of this series. The overall reduced survival using revision for any reason as the end-point at ten years was related to this specific patients population that had various co-morbidities.
Collapse
Affiliation(s)
- Moussa Hamadouche
- Clinical Orthopaedic Research Centre, Department of Reconstructive and Orthopaedic Surgery, Université René Descartes, Hôpital Cochin (AP-HP), Paris, France. .,Clinical Orthopaedic Research Center, Department of Orthopaedic and Reconstructive Surgery, Service A, Centre Hospitalo-Universitaire Cochin- Port Royal, 27 Rue du Faubourg St Jacques, 75014, Paris, France.
| | - Mickael Ropars
- Clinical Orthopaedic Research Centre, Department of Reconstructive and Orthopaedic Surgery, Université René Descartes, Hôpital Cochin (AP-HP), Paris, France.,Department of Orthopaedic Surgery and Traumatology, Pontchaillou University Hospital, 2 Avenue Henri Le Guilloux, 35203, Rennes, France
| | - Camille Rodaix
- Clinical Orthopaedic Research Centre, Department of Reconstructive and Orthopaedic Surgery, Université René Descartes, Hôpital Cochin (AP-HP), Paris, France.,Clinical Orthopaedic Research Center, Department of Orthopaedic and Reconstructive Surgery, Service A, Centre Hospitalo-Universitaire Cochin- Port Royal, 27 Rue du Faubourg St Jacques, 75014, Paris, France
| | - Thierry Musset
- Clinical Orthopaedic Research Centre, Department of Reconstructive and Orthopaedic Surgery, Université René Descartes, Hôpital Cochin (AP-HP), Paris, France.,Clinique Mutualiste de la Porte de Lorient, 3, rue Robert de La Croix, 56324, Lorient Cedex, France
| | - François Gaucher
- Clinical Orthopaedic Research Centre, Department of Reconstructive and Orthopaedic Surgery, Université René Descartes, Hôpital Cochin (AP-HP), Paris, France.,Hotel Dieu, 29120, Pont Labbé, France
| | - David Biau
- Clinical Orthopaedic Research Centre, Department of Reconstructive and Orthopaedic Surgery, Université René Descartes, Hôpital Cochin (AP-HP), Paris, France.,Clinical Orthopaedic Research Center, Department of Orthopaedic and Reconstructive Surgery, Service A, Centre Hospitalo-Universitaire Cochin- Port Royal, 27 Rue du Faubourg St Jacques, 75014, Paris, France
| | - Jean Pierre Courpied
- Clinical Orthopaedic Research Centre, Department of Reconstructive and Orthopaedic Surgery, Université René Descartes, Hôpital Cochin (AP-HP), Paris, France.,Clinical Orthopaedic Research Center, Department of Orthopaedic and Reconstructive Surgery, Service A, Centre Hospitalo-Universitaire Cochin- Port Royal, 27 Rue du Faubourg St Jacques, 75014, Paris, France
| | - Denis Huten
- Clinical Orthopaedic Research Centre, Department of Reconstructive and Orthopaedic Surgery, Université René Descartes, Hôpital Cochin (AP-HP), Paris, France.,Department of Orthopaedic Surgery and Traumatology, Pontchaillou University Hospital, 2 Avenue Henri Le Guilloux, 35203, Rennes, France
| |
Collapse
|
32
|
Gaudin G, Ferreira A, Gaillard R, Prudhon JL, Caton JH, Lustig S. Equivalent wear performance of dual mobility bearing compared with standard bearing in total hip arthroplasty: in vitro study. INTERNATIONAL ORTHOPAEDICS 2016; 41:521-527. [PMID: 27878334 DOI: 10.1007/s00264-016-3346-5] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/06/2016] [Accepted: 11/10/2016] [Indexed: 01/18/2023]
Abstract
PURPOSE Osteolysis in total hip arthroplasty (THA) depends on polyethylene wear and dictates the survival of the prosthesis. Dual mobility in THAs, which is claimed to reduce dislocation risk, has very good long-term clinical results. However, little is known about how the liner wears in this design, compared to the standard single mobility model. METHODS A comparative study looking at wear of a conventional ultra-high-molecular-weight polyethylene liner, using gravimetric measurement, between dual mobility implants and standard implants, was performed on a simulator in accordance with a normed protocol based on the same dimensions, environmental conditions and stresses. A linear regression test was employed. RESULTS Under the same conditions (loading, cycles, sterilization, material and surface roughness), the gravimetric wear (for conventional polyethylene) is comparable between a standard and a dual mobility cup. This correlates to ten year follow-up results of dual mobility cup. DISCUSSION - CONCLUSION This in vitro equivalent wear serves to confirm the very good long-term clinical results observed with dual mobility bearing, whose use should not be restricted by concerns about increased polyethylene wear.
Collapse
Affiliation(s)
- Gaël Gaudin
- Centre Albert Trillat, Hôpital de la Croix-Rousse, 103 Grande Rue de la Croix-Rousse, 69004, Lyon, France
| | - André Ferreira
- Clinique du Parc, 155 Ter Boulevard de Stalingrad, 69006, Lyon, France
| | - Romain Gaillard
- Centre Albert Trillat, Hôpital de la Croix-Rousse, 103 Grande Rue de la Croix-Rousse, 69004, Lyon, France
| | - Jean Louis Prudhon
- Centre Ostéo-articulaire des Cèdres, 5 rue des tropiques, 38130, Echirolles, France
| | - Jacques H Caton
- Institut d'orthopédie, 103 rue Coste, 69300, Caluire et Cuire, France
| | - Sébastien Lustig
- Centre Albert Trillat, Hôpital de la Croix-Rousse, 103 Grande Rue de la Croix-Rousse, 69004, Lyon, France.
| |
Collapse
|
33
|
Dual-mobility arthroplasty failure: a rationale review of causes and technical considerations for revision. INTERNATIONAL ORTHOPAEDICS 2016; 41:481-490. [PMID: 27872981 DOI: 10.1007/s00264-016-3328-7] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/16/2016] [Accepted: 10/17/2016] [Indexed: 12/26/2022]
Abstract
PURPOSE Dual-mobility arthroplasty is an alternative to conventional total hip arthroplasty (THA) in appropriately selected, active adults with degenerative, necrotic or post-traumatic hip disease or with revision hip arthroplasty. Numerous papers have been published with results of dual-mobility arthroplasty, but there have been no comprehensive literature reviews that summarise the most recent findings and help the orthopaedic surgeon facing different scenarios in which revision of one or both components of a dual-mobility arthroplasty is indicated. METHODS We performed a PubMed search for papers published on dual-mobility arthroplasty that provided data on revision and add our experience in order to describe different revision scenarios. We collected data on revision for any reason, for aseptic loosening, for infection, or for dislocation. For each complication, we summarise causes and diagnosis of this complication and describe the direction of possible therapeutic options. RESULTS The dual-mobility arthroplasty offers the benefit of increased stability without compromising clinical outcomes and implant longevity. However, as with conventional arthroplasties, complications are also reported, with the most frequent being cup loosening, dislocation, accelerated wear and infection. Dual-mobility implants also have some specific complications secondary to their specific design, with the presence of a third joint. For example, intraprosthetic dislocation due to retentive failure of the polyethylene (PE) liner on the femoral head is a complication observed exclusively with this type of implant and involves articulation failure between the femoral head and the PE liner. Mechanical conflict with the iliopsoas tendon has also been reported, probably due to femoral head size, cup design, and/or a dysplastic hip. This systematic review of the literature identified several options for treating each complication, and in particular, options regarding conserving or not of one the two articulating devices. CONCLUSIONS These findings can inform discussions relating to risks and benefits of different therapeutic options when performing revision of a dual-mobility arthroplasty.
Collapse
|