1
|
Rankin IA, Goffin J, Khan LAK, Cairns D, Barker SL, Kumar K. Stress shielding of the proximal humerus in stemless anatomic total shoulder arthroplasty. Shoulder Elbow 2024; 16:493-500. [PMID: 39464830 PMCID: PMC11512461 DOI: 10.1177/17585732231168391] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/23/2023] [Accepted: 03/19/2023] [Indexed: 10/29/2024]
Abstract
Background This study aimed to assess the radiographic proximal humerus bony adaptations to stress shielding and associated clinical outcomes following stemless total shoulder arthroplasty. Methods A retrospective review of all patients who underwent stemless total shoulder arthroplasty surgery at our centre from 2010 to 2020 was performed. Results In total, 115 stemless total shoulder arthroplasty utilising a single implant design with a minimum one-year follow-up were identified over a 10-year period. The median follow-up was 3.5 years (range: 1-8.9 years). Evidence of stress shielding was observed in 20 cases (17%), (9 mild (8%), 0 moderate (0%), 11 severe (9%). No significant differences were seen between stress shielding and gender, body mass index, post-operative range-of-motion, patient satisfaction, or Oxford shoulder score. No significant differences were seen between the operative technique and stress shielding. No cases had evidence of humeral lucency. In total, 24 cases (21%) had evidence of glenoid lucency of Lazarus grade 0-3. No cases had Lazarus grades 4 or 5. There was no association between stress shielding and humeral lucency, glenoid lucency, or revision procedure. Discussion Stress shielding in this study occurred at lower rates than anticipated following stemless total shoulder arthroplasty and was not associated with radiographic evidence of lucency, revision procedures, or adverse effect on clinical outcome measures.
Collapse
Affiliation(s)
- Iain A Rankin
- Department of Trauma and Orthopaedics, Aberdeen Upper Limb Unit, Woodend Hospital, Aberdeen, UK
| | - Joaquim Goffin
- Department of Trauma and Orthopaedics, Aberdeen Upper Limb Unit, Woodend Hospital, Aberdeen, UK
| | - L A Kash Khan
- Department of Trauma and Orthopaedics, Aberdeen Upper Limb Unit, Woodend Hospital, Aberdeen, UK
| | - David Cairns
- Department of Trauma and Orthopaedics, Aberdeen Upper Limb Unit, Woodend Hospital, Aberdeen, UK
| | - Scott L Barker
- Department of Trauma and Orthopaedics, Aberdeen Upper Limb Unit, Woodend Hospital, Aberdeen, UK
| | - Kapil Kumar
- Department of Trauma and Orthopaedics, Aberdeen Upper Limb Unit, Woodend Hospital, Aberdeen, UK
| |
Collapse
|
2
|
Barret H, Garret J, Favard L, Bonnevialle N, Collin P, Gauci MO, Boileau P. Long-term (minimum 10 years) survival and outcomes of pyrocarbon interposition shoulder arthroplasty. J Shoulder Elbow Surg 2024:S1058-2746(24)00479-8. [PMID: 39067661 DOI: 10.1016/j.jse.2024.05.026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/12/2024] [Revised: 05/02/2024] [Accepted: 05/10/2024] [Indexed: 07/30/2024]
Abstract
BACKGROUND There are some major controversies surrounding the use and longevity of pyrocarbon interposition shoulder arthroplasty (PISA). The objective of this study was to investigate the long-term survival and outcomes (minimum 10-year) following PISA for osteoarthritis (OA) in young and active patients. METHODS This was a retrospective review of prospectively collected data of patients who underwent PISA (InSpyre; Tornier-Stryker) for OA between 2009 and 2012. Arthroplasty survival was known for 71 patients followed longitudinally for a minimum of 10 years. The clinical and radiologic outcomes were assessed in 62 patients (62 shoulders) reviewed with radiographs. The mean age at surgery was 60 years (range, 23-72 years), and 31 shoulders (50%) underwent prior surgery before PISA. The diagnosis was primary osteoarthritis (POA = 29), post-traumatic osteoarthritis (PTOA = 23), and postinstability osterarthritis (PIOA = 10). Clinical failure was defined as repeat surgical intervention involving prosthesis revision. Clinical outcomes were assessed with the Constant score (CS) and Subjective Shoulder Value (SSV). The mean duration of follow-up was 11 ± 0.6 years (range, 10-14 years). RESULTS Overall, the survival rate was 90% (95% confidence interval [CI] 82.8-96.8) at 5 years and 87% (95% CI 79-94.8) at a 10-year follow-up. Survival was 100% in PTOA (type 1 fracture sequelae) and in PIOA as well as 95% in primary OA with type A glenoid. Revision surgery was significantly higher in biconcave (type B2) glenoid (44%) compared with concentric (type A) glenoid (2%), respectively (P = .002). Among the 7 patients who were revised to reverse shoulder arthroplasty, 5 had painful glenoid erosion and 2 had bipolar (glenoid and humeral) erosion with thinning and finally fracture of the greater tuberosity. Two shoulders with glenohumeral erosion were associated with secondary rotator cuff tears (1 supraspinatus and 1 subscapularis tear). The mean time to revision and revision was 4 ± 1.7 years. Glenoid wear was more often superior (81%) than central (19%), P < .001. For those shoulders not revised, the mean CS and SSV significantly increased from 39 ± 14 to 70 ± 14 points and 34% ± 15% to 75% ± 17%, respectively (P < .001). CONCLUSION PISA is an efficient and durable surgical procedure for the treatment of young and active patients with post-traumatic OA, postinstability OA, and primary OA with concentric (type A) glenoid erosion, but not for those with biconcave (type B2) glenoid. Biconcave (type B2) glenoid and subscapularis tear or insufficiency are risk factors for failure and revision.
Collapse
Affiliation(s)
- Hugo Barret
- Service de Chirurgie Orthopédique et du Sport, Hôpital Pierre Paul Riquet, CHU de Toulouse, France; Clinique Universitaire du Sport, Hôpital Pierre Paul Riquet, Toulouse, France
| | | | - Luc Favard
- Service d'Orthopédie Traumatologie, CHRU Trousseau, Faculté de Médecine de Tours, Université de Tours, Chambray-les-Tours, France
| | - Nicolas Bonnevialle
- Service de Chirurgie Orthopédique et du Sport, Hôpital Pierre Paul Riquet, CHU de Toulouse, France; Clinique Universitaire du Sport, Hôpital Pierre Paul Riquet, Toulouse, France
| | - Philippe Collin
- Department of Orthopedic and Trauma Surgery, CHP Saint-Grégoire, Saint-Grégoire, France; Department of Orthopedic and Trauma Surgery, Clinique Victor Hugo, Paris, France; Department of Orthopedic and Trauma Surgery, American Hospital of Paris, Neuilly-sur-Seine, France
| | - Marc-Olivier Gauci
- Institut Universitaire Locomoteur & Sport, Hôpital Pasteur 2, UR2CA, Côte d'Azur University, CHU de Nice, Nice, France
| | - Pascal Boileau
- Institut de Chirurgie Reparatrice (ICR) - Locomoteur & Sport, Institute for Reconstructive Surgery, Nice, France.
| |
Collapse
|
3
|
Willems JI, Achten G, Crowther MA, Heikenfeld R, Karelse A, van Noort A. Two-year follow-up of the SMR stemless platform shoulder system: a multicenter, prospective clinical study. JSES Int 2024; 8:888-894. [PMID: 39035661 PMCID: PMC11258836 DOI: 10.1016/j.jseint.2024.04.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/23/2024] Open
Abstract
Background The use of stemless shoulder arthroplasty for osteoarthritis has grown substantially over the past decades. The goal of this study is to evaluate the clinical and radiological outcomes of the Lima SMR stemless anatomic and reverse total shoulder arthroplasty. Methods Seventy-three implants in 73 patients (61 anatomic total shoulder arthroplasties [aTSAs] and 12 reverse shoulder arthroplasties [RSAs]) were analyzed with a minimum follow-up of 2 years. The average age in the aTSA group was 65.8 ± 8.7 and 78.3 ± 4.8 in the RSA group. Primary osteoarthritis was the indication in most cases (aTSA 93.7%, RSA 67%). Patients were evaluated preoperatively, at 4, 12, and 24 months postoperatively using the Constant score, the ASES, Oxford Shoulder Score, EuroQol 5 Dimensions 5 Levels questionnaire, range of motion scores, and radiographically. Statistical significance was evaluated using the paired t-test (P < .5). Results At 2-year follow-up, the overall average Constant score significantly improved from 40.0 ± 16.7 to 80.9 ± 21.4 (P < .001). Improvement of the ASES (from 31.7 ± 15.6 to 82.5 ± 19.4) and Oxford Shoulder Score (from 19.1 ± 7.4 to 41.9 ± 7.9) was also significant (P < .001). In the aTSA group, all range of motion scores improved significantly (P < .001). In the RSA group, all range of motion scores improved but only active forward flexion and external rotation in abduction improved significantly (P < .05). Most patients were satisfied or completely satisfied at 24 months (aTSA 93.9%, RSA 100%). Two humeral implants in the RSA configuration showed loosening on the first postoperative day related to excessive forces exerted on the shoulder, both requiring revision to a stemmed implant. In the aTSA group, no signs of radiolucencies, osteolysis, gradual loosening, or migration of the components were seen at the final follow-up. In the RSA group, one case had radiolucent lines with subsidence of the humeral core at 12 months, which had not progressed at 24 months and was asymptomatic. All other RSA cases showed no radiolucent lines, migration, scapular notching, or osteolysis. Three anatomic implants were converted with retention of the glenoid baseplate and humeral core to a reverse arthroplasty due to atraumatic cuff failure (N = 2) and traumatic cuff failure (N = 1). After these procedures, patients were satisfied with their results. There were no other complications. Conclusion The 2-year results presented in this study show good functional and radiological outcomes using the SMR stemless system.
Collapse
Affiliation(s)
- Joost I.P. Willems
- Orthopaedic Department, Medische Kliniek Velsen, Velsen Noord, the Netherlands
| | - Gijs Achten
- Orthopaedic Department, Spaarne Gasthuis, Hoofddorp, the Netherlands
| | - Mark A.A. Crowther
- Orthopaedic Department, North Bristol NHS Trust, Bristol, United Kingdom
| | | | - Anne Karelse
- Orthopaedic Department, ZorgSaam Hospital, Terneuzen, the Netherlands
| | - Arthur van Noort
- Orthopaedic Department, Spaarne Gasthuis, Hoofddorp, the Netherlands
| |
Collapse
|
4
|
Teissier J, Teissier P. Stemless shoulder arthroplasty. Orthop Traumatol Surg Res 2023; 109:103460. [PMID: 36942793 DOI: 10.1016/j.otsr.2022.103460] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/09/2021] [Accepted: 06/22/2022] [Indexed: 11/06/2022]
Abstract
The concept of stemless shoulder arthroplasty was born in 2005. It is now a valid option in the context of either anatomical or reverse shoulder replacement. Several questions have come up over our 15 years of using this system: How was the stemless shoulder arthroplasty concept born? It was motivated by a desire to have epiphyso-metaphyseal fixation using a corolla-shaped impacted anchor design. What are the features of commercially available stemless shoulder arthroplasty implants? The stemless anatomical implants now available have either a cage or central peg that is impacted or a system that is screwed into the epiphysometaphyseal bone. Several companies have introduced stemless reverse implants, some of which have an onlay configuration. How do the results of stemless implants compare to those of traditional stemmed implants? At a mean follow-up of 10 years, the outcomes of stemless TSA can be superimposed with those of traditional stemmed TSA. What are the advantages of stemless shoulder implants? The advantages are their simple implantation, ability to adapt to patient morphology and any malunions, various orientation angles, no stress-shielding, reduced risk of infection and bleeding and less complex revision surgery (if needed). What are the limitations or drawbacks of using stemless implants? The two main limitations are insufficient metaphyseal bone stock and poor bone quality, especially for reverse configurations. What does the future hold for stemless shoulder arthroplasty? Like with traditional stemmed implants, the longevity of stemless shoulder arthroplasty depends on its tribology, which can still be improved. In the future, a stemless implant will need to be convertible like stemmed humeral implants, and if possible, provide an inlay reverse configuration.
Collapse
Affiliation(s)
- Jacques Teissier
- 2, place de l'Europe, 34430 Saint-Jean-de-Vedas, Montpellier Métropole, France.
| | - Philippe Teissier
- 2, place de l'Europe, 34430 Saint-Jean-de-Vedas, Montpellier Métropole, France
| |
Collapse
|
5
|
Bidwai R, Kumar K. Outcomes of different stem sizes in shoulder arthroplasty. J Orthop 2023; 35:37-42. [PMID: 36387763 PMCID: PMC9647328 DOI: 10.1016/j.jor.2022.10.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/11/2022] [Revised: 08/20/2022] [Accepted: 10/21/2022] [Indexed: 11/05/2022] Open
Abstract
Background The successive refinement in implant design and operative technique alongwith improved understanding has resulted in increased incidence of total shoulder arthroplasty (TSA). Simultaneously, the indications of TSA have widened and include a range of shoulder pathologies. Methods Using the keywords and relevant literature, we have described an overview of the different stem sizes used in shoulder arthroplasty. Relevant description of clinical and radiological outcome is done with regards to different stem sizes. Discussion There are plethora of shoulder replacement systems, based on unique philosophy and having their own advantages and disadvantages. Additionally, the rise in ageing population had increased the need for revision TSA, thereby necessitating the judicious choice of implant at primary TSA. We further present the role of cemented and uncemented humeral stems and discuss the findings of finite element analysis. The choice of humeral stem size and use of cemented or uncemented stems have been reported to affect the clinical and radiological outcomes.
Collapse
Affiliation(s)
- Rohan Bidwai
- Aberdeen Upper Limb Unit, Department of Trauma and Orthopaedics, Woodend Hospital, NHS Grampian , Aberdeen, UK
| | - Kapil Kumar
- Aberdeen Upper Limb Unit, Department of Trauma and Orthopaedics, Woodend Hospital, NHS Grampian , Aberdeen, UK
| |
Collapse
|
6
|
Cozzolino A, Guastafierro A, Bernasconi A, Della Rotonda G, Malfi P, Fedele A, Mortellaro M, Minopoli P, Pietroluongo LR, Russo R. Proximal humerus fracture sequelae: are corrective osteotomies still a taboo? The role of three-dimensional preoperative planning and patient-specific surgical guides for proximal humerus corrective osteotomy in combination with reverse shoulder arthroplasty. JSES Int 2022; 7:104-112. [PMID: 36820410 PMCID: PMC9937839 DOI: 10.1016/j.jseint.2022.09.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
Background Symptomatic proximal humeral fracture sequelae (PHFS) represent a surgical challenge due to the altered bone and soft tissue morphology. The purpose of this study was to report the outcome of Multiplanar Corrective Humeral Osteotomies (MCHOs) in combination with reverse total shoulder arthroplasty (rTSA) performed following a three-dimensional (3D) preoperative planning and using a 3D-printed patient-specific surgical instrumentation (PSI) in type 1C, 1D, and 4 PHFS. Methods In this prospective monocentric study, we enrolled patients affected by symptomatic PHFS type 1C, 1D, or 4 of Boileau's classification, treated between 2018 and 2019 with rTSA associated to MCHO and followed-up at 12 and 24 mo. The preoperative and postoperative Constant Score (CS), visual analog scale, and Disabilities of the Arm, Shoulder and Hand (DASH) score were recorded. All patients underwent a preoperative computed tomography, then a dedicated software was used to run a segmentation algorithm on computed tomography images. Metaphyseal bone cuts were virtually performed before surgery in all patients, and a 3D-printed PSI was used to reproduce the planned osteotomies in vivo. Results Twenty patients completed a 2-y follow-up. The mean (± standard deviation) CS, visual analog scale, and DASH values improve from 24.3 (± 8.8), 6.5 (± 1.3), 60.7 (± 9.6) preoperatively, to 67.7 (± 11.4), 1.6 (± 0.8), 24.1 (± 13.1) points after surgery, respectively. The minimally clinical important difference for CS and DASH score was achieved in 95% of patients. No major complication was observed. One patient showed an unexplained worsening of clinical scores between the 12 and the 24-mo follow-up, while in one patient bone resorption of the greater tuberosity was observed on radiographs at 2 y, with no clinical impact. Conclusion The combination of preoperative 3D planning and intraoperative use of 3D-printed PSI to perform MCHO as concurrent procedure in the context of rTSA in the treatment of Boileau type 1C, 1D, and 4 PHFS may lead to a satisfactory clinical outcome at 2 y of follow-up.
Collapse
Affiliation(s)
- Andrea Cozzolino
- Department of Public Health, University of Naples Federico II, Naples, Italy
| | | | - Alessio Bernasconi
- Department of Public Health, University of Naples Federico II, Naples, Italy
| | | | | | - Alfonso Fedele
- Department of Orthopedic Surgery, Pineta Grande Hospital, Castelvolturno, Italy
| | - Marco Mortellaro
- Department of Orthopedic Surgery, Pineta Grande Hospital, Castelvolturno, Italy
| | - Paolo Minopoli
- Department of Orthopedic Surgery, Pineta Grande Hospital, Castelvolturno, Italy
| | | | - Raffaele Russo
- Department of Public Health, University of Naples Federico II, Naples, Italy,Corresponding author: Raffaele Russo, MD, Department of Orthopedic Surgery, Pineta Grande Hospital, Castelvolturno (CE), Italy.
| |
Collapse
|
7
|
Russo R, Cozzolino A, Guastafierro A, Della Rotonda G, Viglione S, Ciccarelli M, Mortellaro M, Minopoli P, Fiorentino F, Pietroluongo LR. Use of 3D Planning and Patient-specific Guides for Proximal Humerus Corrective Osteotomy Associated With Shoulder Prosthesis Implantation in Proximal Humeral Varus Malunion. Tech Hand Up Extrem Surg 2022; 26:131-138. [PMID: 34753888 DOI: 10.1097/bth.0000000000000372] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
Humeral stem prosthesis implantation in case of proximal humerus varus malunion (type 1D fracture sequelae) is often complicated by greater tuberosity fracture and by posterosuperior rotator cuff iatrogenic damage. Moreover, the varus malunited humeral head could lead to scapular impingement and reduce the range of motion. To address this problem, we introduced a new surgical procedure consisting in a proximal humerus osteotomy, planned with three-dimensional (3D) preoperative virtual surgery, and performed with patient-specific surgical guides, to correct humerus deformity before the implantation of the prosthetic humeral stem. A 3D evaluation of the deformity, based on the comparison to the healthy contralateral side or to anatomical standard values, is firstly performed. The metaphyseal osteotomy is then planned and virtually performed. To faithfully reproduce the planned correction, 3D printed surgical guides are prepared. Before the surgery, it is advisable to perform a simulation of the planned osteotomies to verify their real feasibility and to find any critical issues. Preliminary outcomes of this surgical technique are encouraging, but formal studies are warranted to validate its clinical utility and longevity of results.
Collapse
Affiliation(s)
- Raffaele Russo
- Department of Orthopedic Surgery, Pineta Grande Hospital, Caserta
| | - Andrea Cozzolino
- Department of Orthopedic Surgery, Pineta Grande Hospital, Caserta
| | | | | | - Stefano Viglione
- Department of Orthopedic Surgery, Pineta Grande Hospital, Caserta
| | | | | | | | | | | |
Collapse
|
8
|
Simon MJK, Coghlan JA, Hughes J, Wright W, Dallalana RJ, Bell SN. Mid-term outcomes of a stemless ceramic head anatomic total shoulder replacement. BMC Musculoskelet Disord 2022; 23:50. [PMID: 35033044 PMCID: PMC8760766 DOI: 10.1186/s12891-021-04988-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/12/2021] [Accepted: 12/23/2021] [Indexed: 11/24/2022] Open
Abstract
Background In an anatomic shoulder replacement (aTSR) good results have been reported with the use of a stemless humeral prosthesis. In vitro a ceramic articulation with polyethylene has been shown to produce less polyethylene wear particles than with metal. This study aims to evaluate clinical and radiographic results of a stemless aTSR with a ceramic head articulating with a polyethylene glenoid component, with mid-term follow-up. Methods All patients (n = 92) in this prospective study had an aTSR utilizing a stemless humeral component with a ceramic head and a cemented double pegged cemented polyethylene glenoid component for glenohumeral osteoarthritis. Pre- and postoperative clinical evaluations at 2 years were performed using the ASES score, Constant score, SPADI score, DASH score, VAS pain score, patient satisfaction and range of motion. There was a 5-year evaluation of SPADI, ASES, pain, and satisfaction, plus radiographic assessment of glenoid component radiolucent lines and humeral osteolysis. Results Seventy-four cases (68.1 ± 7.1 years) had a five-year follow-up and demonstrated active elevation improvement from 91.3° preoperatively to 151.1° (p < 0.001). Further improvement was identified with the ASES from 41.6 to 94.3, the SPADI from 62.9 to 4.3, VAS pain from 5.6 to 0.4 (0–10), and satisfaction levels were at 96%. Sixty-two cases had no glenoid radiolucent lines with a maximum Lazarus score of 2 in one patient. Constant scores, available up to 2 years, improved significantly from 30.3 to 77.9 (p < 0.001). There was one case that required revision for glenoid loosening. Conclusions Overall, the 5-year results of this ceramic head prosthesis demonstrated good radiographic and clinical outcomes. Trial registration ACTRN12613001183774. Registered: 29 October 2013 - Retrospectively registered. Australian New Zealand Clinical Trials Registry (ANZCTR).
Collapse
Affiliation(s)
- Maciej J K Simon
- Melbourne Shoulder and Elbow Centre, 1/80 Beach Road, Sandringham, VIC, 3191, Australia. .,University Medical Center Schleswig-Holstein, Campus Kiel, Department of Orthopaedics and Trauma Surgery, Arnold-Heller-Strasse 3, 24105, Kiel, Germany.
| | - Jennifer A Coghlan
- Melbourne Shoulder and Elbow Centre, 1/80 Beach Road, Sandringham, VIC, 3191, Australia.,Department of Surgery, (School of Clinical Sciences, Monash Health) Monash University, Monash University, Melbourne, VIC, Australia
| | - Jeff Hughes
- Sydney Shoulder and Elbow Associates, Chatswood, Sydney, Australia
| | | | | | - Simon N Bell
- Melbourne Shoulder and Elbow Centre, 1/80 Beach Road, Sandringham, VIC, 3191, Australia.,Department of Surgery, (School of Clinical Sciences, Monash Health) Monash University, Monash University, Melbourne, VIC, Australia
| |
Collapse
|
9
|
Park H, Haskoor J, Domingo-Johnson EL, Srikumaran U. Stemless Total Shoulder Arthroplasty for a 4-Part Proximal Humerus Malunion and Post-traumatic Arthritis: A Case Report. JBJS Case Connect 2021; 11:01709767-202106000-00049. [PMID: 33886518 DOI: 10.2106/jbjs.cc.20.00902] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
CASE We present a 62-year-old left-hand-dominant woman with history of renal failure, osteoporosis, and 4-part proximal humerus fracture malunion with subsequent post-traumatic arthritis of the left glenohumeral joint. After conservative treatments failed to relieve her symptoms, the patient underwent stemless total shoulder arthroplasty (TSA) because of concerns that her proximal humerus could not accommodate a stemmed implant. At 2 and a half-years postoperative, the patient demonstrated significant improvement of symptoms without signs of radiographic loosening. CONCLUSION In the setting of proximal humerus malunion with post-traumatic arthritis, clinical improvement without implant loosening can be achieved with stemless TSA, even in the setting of compromised bone quality.
Collapse
Affiliation(s)
- Hannah Park
- University of New England College of Osteopathic Medicine, Biddeford, Maine
| | - John Haskoor
- The Division of Shoulder Surgery, Department of Orthopaedic Surgery, The Johns Hopkins University, Baltimore, Maryland
| | | | - Uma Srikumaran
- The Division of Shoulder Surgery, Department of Orthopaedic Surgery, The Johns Hopkins University, Baltimore, Maryland
| |
Collapse
|
10
|
Willems JIP, Hoffmann J, Sierevelt IN, van den Bekerom MPJ, Alta TDW, van Noort A. Results of stemless shoulder arthroplasty: a systematic review and meta-analysis. EFORT Open Rev 2021; 6:35-49. [PMID: 33532085 PMCID: PMC7845565 DOI: 10.1302/2058-5241.6.200067] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Stemless shoulder arthroplasty relies solely on cementless metaphyseal fixation and is designed to avoid stem-related problem such as intraoperative fractures, loosening, stress shielding or stress-risers for periprosthetic fractures. Many designs are currently on the market, although only six anatomic and two reverse arthroplasty designs have results published with a minimum of two-year follow-up. Compared to stemmed designs, clinical outcome is equally good using stemless designs in the short and medium-term follow-up, which is also the case for overall complication and revision rates. Intraoperative fracture rate is lower in stemless compared to stemmed designs, most likely due to the absence of intramedullary preparation and of the implantation of a stem. Radiologic abnormalities around the humeral implant are less frequent compared to stemmed implants, possibly related to the closer resemblance to native anatomy. Between stemless implants, several significant differences were found in terms of clinical outcome, complication and revision rates, although the level of evidence is low with high study heterogeneity; therefore, firm conclusions could not be drawn. There is a need for well-designed long-term randomized trials with sufficient power in order to assess the superiority of stemless over conventional arthroplasty, and of one design over another.
Cite this article: EFORT Open Rev 2021;6:35-49. DOI: 10.1302/2058-5241.6.200067
Collapse
Affiliation(s)
| | | | - Inger N Sierevelt
- Spaarne Gasthuis, Hoofddorp, The Netherlands.,Xpert Orthopedics, Amsterdam, The Netherlands
| | | | | | | |
Collapse
|
11
|
|
12
|
Huber J, Irlenbusch U, Kääb MJ, Reuther F, Kohut G, Judge A. Treatment effects of reverse total shoulder arthroplasty - a simple method to measure outcomes at 6, 12, 24 and 60 months for each patient. BMC Musculoskelet Disord 2020; 21:397. [PMID: 32571282 PMCID: PMC7310507 DOI: 10.1186/s12891-020-03427-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/05/2020] [Accepted: 06/16/2020] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Although shoulder arthroplasty is less common than knee or hip arthroplasty, the number of procedures being performed is increasing rapidly. The treatment effect is a simple method to measure outcome of joint replacement. The method was applied to measure results of total hip/knee arthroplasty but not yet for shoulder arthroplasty. METHODS Included were patients with unilateral cuff arthropathy (Hamada grades > = 2) treated with reversed total shoulder arthroplasty (RSA) in this prospective multicenter study. The patients were assessed with the ASES questionnaire. The treatment effects (TE) was calculated for each patient. TE = score reduction/baseline score. A positive TE means amelioration, TE = 0 unchanged, and a negative TE means worse. The primary aim was to calculate the TE's for RSA at 6, 12, 24, and 60 months postoperatively. The secondary aim was to analyze the influence of confounders (preoperative Hamada grade, age, gender, dominance, side of the affected shoulder, general co-morbidities measured using ASA grade). RESULTS Two hundred three patients were included for this analysis of whom 183 patients had a complete 2 year follow up. Two years postoperatively the mean ASES score augmented significant from 20.5 to 78.7 (p < 0.001). The 2 year TE's ranged from 1 to 0.09. We had no patient with a negative TE. A higher Hamada grade was associated with better TE's (Hamada grade 4+ vs. 2, p-value 0.042). For age and dominant side there were weak associations where those aged 80+ and dominant side had better TE's. The patients with higher ASA grade had lower TE's (ASA grade 4+ vs. 1, p-value 0.013). The mean TE's were 0.77 at 6-months, 0.81 at 1 year, 0.76 at 2 years and 0.73 at 5 years. CONCLUSIONS The outcome for reverse shoulder arthroplasty can be measured with the treatment effect method; the 2 years TE's vary from 1 to 0.09. The mean treatment effects change little in the first five postoperative years (from 0.73 to 0.81). The confounders for better TE's were: higher severity of cuff arthropathy (Hamada grade 3, 4 and 5), less co-morbidities (ASA Grade 1), higher age (80+) and dominant side. Gender did not influence the 2-year TE's. TRIAL REGISTRATION Comité intercantonal d'éthique (Jura, Fribourg, Neuchâtel), number 01/2008, 24.09.2008.
Collapse
Affiliation(s)
- Joerg Huber
- Department of Orthopedics, Stadtspital Triemli, Birmensdorferstr. 497, 8063, Zurich, CH, Switzerland.
| | - Ulrich Irlenbusch
- Orthopedic Clinics, Marienstift, Wachsenburgallee 12, D 99310, Arnstadt, Germany
| | - Max J Kääb
- Sportorthopädicum Straubing, Bahnhofplatz 27, D 94315, Straubing, Germany
| | - Falk Reuther
- DRK Kliniken Köpenick, Salvador-Allende-Strasse 2-8, D 12559, Berlin, Germany
| | - Georges Kohut
- Clinique generale, Rue Hans Geiler 6, 1700, Fribourg, CH, Switzerland
| | - Andy Judge
- Musculoskeletal Research Unit, Translational Health Sciences, Bristol Medical School, University of Bristol, Learning & Research Building, Southmead Hospital, Bristol, BS10 5NB, UK
- Nuffield Department of Orthopedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Windmill Road, Headington, OX3 7LD, UK
- MRC Lifecourse Epidemiology Unit, Southampton General Hospital, University of Southampton, Southampton, SO16 6YD, UK
| |
Collapse
|
13
|
Peng W, Ou Y, Wang C, Wei J, Mu X, He Z. The short- to midterm effectiveness of stemless prostheses compared to stemmed prostheses for patients who underwent total shoulder arthroplasty: a meta-analysis. J Orthop Surg Res 2019; 14:469. [PMID: 31884957 PMCID: PMC6936155 DOI: 10.1186/s13018-019-1515-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/10/2019] [Accepted: 12/11/2019] [Indexed: 11/20/2022] Open
Abstract
BACKGROUND To systematically compare the short- to midterm effectiveness of stemless prostheses to that of stemmed prostheses for patients who underwent total shoulder arthroplasty (TSA) and to provide a guideline for clinical decision-making. METHODS PubMed, the Cochrane Library, and Web of Science were searched with the given search terms until July 2019 to identify published articles evaluating the clinical outcomes for stemless prostheses compared with stemmed prostheses for patients who underwent TSA. Data extraction and the quality assessment of the included studies were independently performed by two authors. Stata software 14.0 was used to analyze and synthesize the data. RESULTS Two randomized controlled trials and six case-controlled studies with a total of 347 shoulders were included in this meta-analysis. The results of this meta-analysis showed that there were no significant differences between the stemless and stemmed prostheses in terms of the Constant score, pain score, strength, activities of daily living, postoperative range of motion (ROM), and postoperative maximum active ROM. CONCLUSIONS This is the first meta-analysis reporting the clinical results of stemless TSA in the short- to midterm follow-up period. Both types of shoulder prostheses were similar in achieving satisfactory clinical outcomes.
Collapse
Affiliation(s)
- Wei Peng
- Department of Anatomy and Cell Biology, Justus-Liebig University, 35392, Giessen, Germany
| | - Yufu Ou
- Department of Orthopaedics, The People's Hospital of Guangxi Zhuang Autonomous Region, Nanning, 530021, China
| | - Chenglong Wang
- Department of Orthopaedics, The People's Hospital of Guangxi Zhuang Autonomous Region, Nanning, 530021, China
| | - Jianxun Wei
- Department of Orthopaedics, The People's Hospital of Guangxi Zhuang Autonomous Region, Nanning, 530021, China
| | - Xiaoping Mu
- Department of Orthopaedics, The People's Hospital of Guangxi Zhuang Autonomous Region, Nanning, 530021, China
| | - Zhian He
- Department of Orthopaedics, The Affiliated Chencun Hospital of Shunde Hospital, Southern Medical University, Foshan, 528300, China
| |
Collapse
|
14
|
Abstract
Background The number of anatomic total shoulder (TSA), hemiarthroplasty (HA), and reverse total shoulder arthroplasties (RTSA) is rapidly increasing in the United States. Stemless shoulder arthroplasty has numerous theoretical advantages, including preserved bone stock, decreased operating time, reduced rate of intraoperative humerus fracture, and flexibility of anatomic reconstruction. Only recently studies with more than 5 years of mean follow-up have become available. Methods The MEDLINE database was systematically queried to identify all studies reporting outcomes regarding anatomic or reverse stemless shoulder arthroplasty. Studies were categorized according to mean reported follow-up. Outcome scores and range of motion measurements were compiled. Complication and revision rates due to failure of the humeral or glenoid components were summarized. Results Nineteen TSA and HA studies with a total of 1115 patients were identified, with 4 studies and 162 patients with a mean follow-up between 60 and 120 months. Six RTSA studies with a total of 346 patients were identified, all with a mean follow-up between 18 and 60 months. There was a reliable improvement in outcomes compared with preoperative scores across studies. A cumulative 0.7% (8 of 1115) humeral component complication rate was found for TSA and HA components. There was a cumulative 1.7% (6 of 346) humeral complication rate for RTSA prostheses. Conclusions In the studies reporting similar outcome measures, there were reliable improvements on par with stemmed counterparts. Aggregate complication rates appear similar to those published in the literature for stemmed components. Evidence supporting the utility and safety of stemless designs would be strengthened by longer-term follow-up and additional prospective comparative studies.
Collapse
|
15
|
Pinto MC, Archie AT, Mosher ZA, Ransom EF, McGwin G, Fehringer EV, Brabston EW, Ponce BA. Radiographic restoration of native anatomy: a comparison between stemmed and stemless shoulder arthroplasty. J Shoulder Elbow Surg 2019; 28:1595-1600. [PMID: 30982698 DOI: 10.1016/j.jse.2019.01.015] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/08/2018] [Revised: 01/23/2019] [Accepted: 01/27/2019] [Indexed: 02/01/2023]
Abstract
BACKGROUND Shoulder arthroplasty is a reliable procedure for patients with degenerative glenohumeral disease, and reproduction of native shoulder anatomy leads to superior outcomes. The aim of this study was to compare the ability of stemmed and stemless implants to radiographically restore native glenohumeral anatomy. METHODS Shoulder arthroplasties were performed in 79 patients, with 58 receiving a stemless implant and 21 receiving a stemmed implant. Preoperative and postoperative radiographs were assessed for humeral head height, humeral head centering, humeral head medial offset, humeral head diameter, humeral neck angle, and lateral humeral offset by 2 independent viewers. Measurements were scored and summed to identify the anatomic reconstruction index (ARI). Radiographic measurements were compared using the Student t test, and significance was set at P < .05 for all statistical analyses. Interobserver agreement of radiographic analyses was assessed using the intraclass correlation coefficient, finding excellent reliability (intraclass correlation coefficient, 0.92). RESULTS Five of six radiographic measurements along with the calculated ARI demonstrated no differences between stemmed and stemless shoulder implants (humeral head diameter, P = .651; humeral head height, P = .813; humeral head medial offset, P = .592; lateral humeral offset, P = .311; humeral head centering, P = .414; and ARI, P = .862). Stemless implants showed improved restoration of the native humeral neck angle (0° for stemless vs. -3° for stemmed, P = .017). CONCLUSION Radiographic restoration of anatomy is similar for stemmed and stemless shoulder arthroplasty implants.
Collapse
Affiliation(s)
- Martim C Pinto
- Division of Orthopaedic Surgery, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Adam T Archie
- Division of Orthopaedic Surgery, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Zachary A Mosher
- Division of Orthopaedic Surgery, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Erin F Ransom
- Division of Orthopaedic Surgery, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Geral McGwin
- Division of Orthopaedic Surgery, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Edward V Fehringer
- Division of Orthopaedic Surgery, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Eugene W Brabston
- Division of Orthopaedic Surgery, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Brent A Ponce
- Division of Orthopaedic Surgery, University of Alabama at Birmingham, Birmingham, AL, USA.
| |
Collapse
|
16
|
Abstract
The fourth generation of humeral components currently are being used in anatomic shoulder arthroplasty. Anatomic shoulder arthroplasty implants have evolved to better re-create anatomy, improve fixation, preserve bone, and facilitate revision surgery. Most of the design changes for shoulder arthroplasty implants have centered on the humeral stem, with a transition to shorter, metaphyseal humeral stems. Many of these humeral component design changes may be beneficial; however, long-term studies are necessary to determine if the results of anatomic shoulder arthroplasty with the use of newer humeral components can match those of anatomic shoulder arthroplasty with the use of older humeral components.
Collapse
|
17
|
Brolin TJ, Cox RM, Abboud JA, Namdari S. Stemless Shoulder Arthroplasty: Review of Early Clinical and Radiographic Results. JBJS Rev 2017; 5:e3. [DOI: 10.2106/jbjs.rvw.16.00096] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
|
18
|
Affiliation(s)
- Kamal I Bohsali
- 1Jacksonville Orthopaedic Institute, Jacksonville Beach, Florida 2Section of Orthopaedic Surgery, Department of Surgery, Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada 3Department of Orthopaedics, University of Texas HSC-San Antonio, San Antonio, Texas
| | | | | |
Collapse
|
19
|
Radiological and functional 24-month outcomes of resurfacing versus stemmed anatomic total shoulder arthroplasty. INTERNATIONAL ORTHOPAEDICS 2016; 41:375-384. [PMID: 27761628 DOI: 10.1007/s00264-016-3310-4] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/23/2016] [Accepted: 09/27/2016] [Indexed: 10/20/2022]
Abstract
PURPOSE This study compared clinical and radiographic outcomes of patients undergoing resurfacing total shoulder arthroplasty (TSA) with those treated with a stemmed TSA. METHODS Patients with primary osteoarthritis who underwent humeral resurfacing (RES) or stemmed (STA) TSA were identified in our shoulder arthroplasty register for retrospective analysis. Standard radiographs and clinical/patient-rated assessments were made up to 24 months post-surgery. Implant revisions were assessed. Patients were frequency-matched in a 1:1 (RES:STA) ratio based on gender and age, and compared with regard to operation time and shoulder function (Constant, SPADI and Quick DASH scores). Mixed models with statistical adjustments were applied. RESULTS From 2006 to 2014, 44 RES and 137 STA operations were performed in 157 patients; one and two revisions were recorded in the RES and STA group, respectively. The final matched cohort included a total of 69 patients and 37 operations per treatment group. Resurfacing TSA was 17 min shorter (95%CI: 5-28) compared to the stemmed procedure (p = 0.005). RES and STA patients showed significant functional improvement six months post-implantation, yet all measured scores did not differ between the groups at 2 years (p ≥ 0.131). The status of static centering of the humeral head, acromiohumeral distance, and a lack of signs of implant loosening were also similar between treatments. CONCLUSION Similar 24-month post-operative radiological and functional outcome is achieved by RES and STA patients, even with a shorter RES surgery time. Larger cohorts and longer follow-up are required to better assess implant survival.
Collapse
|