Gökler DJ, Karácsony AF, Faragó D, Szebényi G, Kiss RM, Pap K. The effect of sterilization and storage on the viscoelastic properties of human tendon allografts - Continued: Storage for 0 to 4 months. J Biomech 2024; 162:111904. [PMID: 38134466 DOI: 10.1016/j.jbiomech.2023.111904] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2023] [Revised: 12/09/2023] [Accepted: 12/13/2023] [Indexed: 12/24/2023]
Abstract
The role of donor-derived tendons, also known as allografts, in anterior cruciate ligament replacement surgeries is steadily increasing. Before surgery, temporary storage and, in most cases, sterilization are essential. It is, thus, crucial to determine how these procedures alter the grafts' biomechanical properties. The purpose of this research was to analyze the effect of different sterilization methods (native, frozen, frozen + 21 kGy gamma irradiation, frozen + 21 kGy electron beam irradiation) and storage durations (0 to 4 months) on the deformation and creep of two tendon types (tibialis anterior, peroneus longus). 80 tibialis anterior and 83 peroneus longus tendons from 51 human cadavers were included. The samples were removed, placed in a radio-cryoprotectant solution, then slowly cooled, sterilized and stored at -80 °C. All groups were subject to 60 s static creep test with 250 N load. Deformation during the loading phase, creep during static loading, and the ratio of these two were evaluated. Deformation at the end of the loading phase and creep consistently exhibited significantly smaller values in the tibialis anterior compared to the peroneus longus type, as well as in electron beam-sterilized grafts as opposed to gamma beam-sterilized ones. Prolonged storage periods (within 0 to 4 months) resulted in a notable increase in these values, particularly in deformation. Based on the experimental data, the tibialis anterior tendon type and sterilization by gamma beam irradiation are better choices for anterior cruciate ligament reconstruction than the peroneus longus and sterilization by electron beam. Increased storage time affects negatively the evaluated mechanical properties.
Collapse
Affiliation(s)
- Daniella Judit Gökler
- Budapest University of Technology and Economics, Faculty of Mechanical Engineering, Department of Mechatronics, Optics, and Mechanical Engineering Informatics, Hungary
| | - Atilla Ferenc Karácsony
- Semmelweis University Budapest, Department of Traumatology, Hungary; Buda Hospital of the Hospitaller Order of Saint John of God, Department of Orthopedics, Hungary
| | - Dénes Faragó
- Budapest University of Technology and Economics, Faculty of Mechanical Engineering, Department of Mechatronics, Optics, and Mechanical Engineering Informatics, Hungary
| | - Gábor Szebényi
- MTA-BME Lendület Lightweight Polymer Composites Research Group, Hungary; Budapest University of Technology and Economics, Faculty of Mechanical Engineering, Department of Polymer Engineering, Hungary.
| | - Rita Mária Kiss
- Budapest University of Technology and Economics, Faculty of Mechanical Engineering, Department of Mechatronics, Optics, and Mechanical Engineering Informatics, Hungary
| | - Károly Pap
- Semmelweis University Budapest, Department of Traumatology, Hungary; Uzsoki Hospital, Department of Orthopedics and Traumatology, Hungary
| |
Collapse
|
2
|
Rivera PM, Dhytadak D, Cunningham G. Reconstruction of Chronic, Retracted Pectoralis Major Tendon Tear With Achilles Tendon Allograft. Arthrosc Tech 2023; 12:e449-e452. [PMID: 37138694 PMCID: PMC10149781 DOI: 10.1016/j.eats.2022.11.027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/01/2022] [Accepted: 11/10/2022] [Indexed: 05/05/2023] Open
Abstract
Rupture of pectoralis major tendon (PMT) is an uncommon injury, but its incidence has been increasing in the past 2 decades. Although open repair of the torn tendon is the preferred choice of treatment in acute and chronic cases, this often is not possible for chronic retracted tendon injuries. While several techniques have been described for PMT reconstruction, these allografts and autografts are often smaller and less thick than the native PMT. In this study, we describe the use of the Achilles tendon allograft with unicortical suture buttons for the reconstruction of a chronic and retracted PMT. Furthermore, the advantages and disadvantages of this technique are discussed.
Collapse
Affiliation(s)
- Paolo Miguel Rivera
- Centre Epaule Coude la Colline, Geneva, Switzerland
- Address correspondence to Paolo Miguel O. Rivera, M.D., Centre Epaule Coude la Colline, Geneva, Switzerland.
| | | | - Gregory Cunningham
- Centre Epaule Coude la Colline, Geneva, Switzerland
- Geneva University Hospitals, Geneva, Switzerland
- Faculty of Medicine, Geneva, Switzerland
| |
Collapse
|
3
|
Nonlinear fiber-bundle-cells-based phenomenological modeling of human tissue samples. Biomech Model Mechanobiol 2022; 21:1803-1823. [DOI: 10.1007/s10237-022-01621-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2022] [Accepted: 08/01/2022] [Indexed: 11/02/2022]
Abstract
AbstractCertain assemblies of fibers, called fiber bundles, play a crucial role in the statistical macroscale properties of fibrous structures like natural or artificial materials. Based on the concept of using idealized statistical fiber bundle cells (FBCs) as model elements, the software named FiberSpace was developed by us earlier for the phenomenological modeling of the tensile test process of real fibrous structures. The model fibers of these FBCs had been considered linear elastic, which was suitable for modeling certain textiles and composites. However, the biological tissues are multilevel structures with fiber-like building elements on every structural level where the fiber elements on the dominant level are statistical bundles of elementary fibers. Hence, their modeling required us to introduce model fibers of nonlinear mechanical behavior and derive the proper mathematical formulas for the calculation of the expected tensile force processes of the FBCs. Accordingly, we developed a new version of FiberSpace. The proposed nonlinear FBCs-based modeling method is essentially phenomenological that decomposes the measured and averaged stress–strain curve into the weighted sum of the responses of different idealized nonlinear FBCs. However, this decomposition can give certain information about the fibrous structure and some details of its damage and failure sub-processes. A special application of nonlinear E-bundles, where the measured stress–strain curve is expanded into a product-function series, may give another type of description for the failure process and can be applied to single measurements of structured failure process containing significant peaks and drops as well. The fitted phenomenological FBC models provide a decomposition of the measured force–strain curve, which enables to construct informative damage and failure maps. The applicability of the phenomenological modeling method and the fitting procedure is demonstrated with the tensile test data of some human and animal tissues, such as facial nerves and tendons.
Collapse
|
4
|
Farago D, Kozma B, Kiss RM. Categorize the existing clamps used for tensile test of human graft- a systematic review. BMC Musculoskelet Disord 2022; 23:707. [PMID: 35879684 PMCID: PMC9316330 DOI: 10.1186/s12891-022-05650-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/28/2021] [Accepted: 07/13/2022] [Indexed: 11/13/2022] Open
Abstract
BACKGROUND The use of tendon allografts for orthopedic repair has gained wide acceptance in recent years, most notably in anterior cruciate tendon reconstruction. Multiple studies support the use of tendon allografts and the benefits of its use are well accepted and understood. One of the important criteria of the use of tendon allografts is statistically similar histological and biomechanical properties to autographs. The aim of this systematic literature review is to investigate and categorize existing clamps used in the determination of the biomechanical properties of tendons such as maximum load, maximum strength, modulus of elasticity, ultimate strain, and stiffness. A variety of clamps for use during the endurance test of tendons were categorized according to the temperature used during the measurement. The clamps are divided into three groups: room temperature, cooled and heated clamps. The second goal of our review is to overview of clamps on the following aspects: name of clamp, author and date, type of clamps, type of endurance test (static or dynamic), type preloading (dynamic or static), type of tendon and measured and calculated parameters, and summarize in Table 3, as a comprehensive catalogue. METHODS This systematic review was carried out in keeping with the PRISMA 2020 E&E and the PRISMA-S guidelines and checklists. A search was conducted for publications dating between 1991 and February 28th 2022 through three electronic databases (Web of Science, Scopus, and PubMed). We used Critical Appraisal Skills Program checklist to check the quality of included articles. RESULTS The database search and additional sources resulted in 1725 records. 1635 records eliminated during the screening for various reasons (case report, other languages, book chapter, unavailable text/conference abstract, unrelated topic). The number of articles used in the final synthesis was 90. A variety of clamps for use during the endurance test of tendons were identified and categorized according to the temperature used during the measurement. Based on this, the clamps are divided into three groups: room temperature, cooled or heated clamps. CONCLUSIONS On the basis of the systematic literature review, mechanical parameters determined by usage with cooled clamps proved to be more reliable than with those at room temperature and with heated clamps. The collected information from the articles included name of clamp, author and date, type of clamps, type of endurance test (static or dynamic), type preloading (dynamic or static), type of tendon and measured and calculated parameters given in Table 3. summarized. The main advantage of the cooled clamps is that there is no limit to the type and length of the tendon. This study provides an overview of clamps and does not represent the modernity of any method.
Collapse
Affiliation(s)
- Denes Farago
- Cooperation Research Center for Biomechanics, Faculty of Mechanical Engineering, Budapest University of Technology and Economics, Budapest, Hungary.
- Department of Mechatronics, Optics and Mechanical Engineering Informatics, Faculty of Mechanical Engineering, Budapest University of Technology and Economics, Budapest, Hungary.
| | - Blanka Kozma
- Department of Biomedical Engineering, SUNY University at Buffalo, Buffalo, USA
| | - Rita Maria Kiss
- Department of Mechatronics, Optics and Mechanical Engineering Informatics, Faculty of Mechanical Engineering, Budapest University of Technology and Economics, Budapest, Hungary
| |
Collapse
|
5
|
Biomechanics of hamstring tendon, quadriceps tendon, and bone-patellar tendon-bone grafts for anterior cruciate ligament reconstruction: a cadaveric study. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY 2022; 33:1067-1074. [PMID: 35362777 DOI: 10.1007/s00590-022-03247-6] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/17/2021] [Accepted: 03/09/2022] [Indexed: 10/18/2022]
Abstract
PURPOSE The three most commonly used autografts for anterior cruciate ligament reconstruction (ACL) are: bone-patellar tendon-bone (BTB), hamstring tendons (HT), and quadriceps tendon (QT). A cadaveric study was performed to determine if there were any differences in mechanical and structural properties under biomechanical testing. METHODS Twenty-seven graft specimens were harvested from 9 human cadaveric legs. Mean donor age was 75.2 years (range 53-85 years). Twenty-two specimens (8 HT, 7 QT, and 7 BTB) completed cyclic preconditioning from 50 to 800 N for 200 cycles and a load to failure test at an extension rate of 1 mm/s. Structural and mechanical properties of BTB, HT, and QT grafts were compared using a one-way ANOVA and Tukey's honest significant difference. RESULTS There was no difference in the ultimate load to failure (N) across all 3 graft types (p = 0.951). Quadriceps tendon demonstrated greater cross-sectional area (mm2) when compared to both HT and BTB (p = 0.001) and was significantly stiffer (N/mm) than HT but not BTB (p = 0.004). Stress (N/mm2) of the HT at ultimate load was greater than QT but not BTB (p = 0.036). Elastic modulus (MPa) of HT was greater than both QT and BTB (p = 0.016). CONCLUSION There was no difference in the ultimate load to failure of BTB, HT, and QT grafts harvested from the same specimens. All 3 grafts had similar loads to failure with a significant increase in stiffness when compared to the native ACL. Furthermore, QT demonstrated more favourable structural properties compared to HT and BTB with greater cross-sectional area to both HT and BTB and greater stiffness compared to HT.
Collapse
|
6
|
Gökler DJ, Faragó D, Szebényi G, Kiss RM, Pap K. The effect of sterilization and storage on the viscoelastic properties of human tendon allografts. J Biomech 2021; 127:110697. [PMID: 34419827 DOI: 10.1016/j.jbiomech.2021.110697] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2021] [Revised: 08/10/2021] [Accepted: 08/12/2021] [Indexed: 11/17/2022]
Abstract
Allografts have become increasingly preferred for anterior cruciate ligament replacement purposes. The risk of infections necessitates thorough sterilization procedures, and the allografts usually need to be stored prior to surgery. Classical mechanical tests have been performed with various types of tendons, however, tibialis anterior and peroneus longus tend to suffer the least biomechanical changes after irradiation. Only few results are available of the strain and creep behaviour of tendons, even though this information is necessary to provide suitable allografts. The aim of the present study is to analyze the effect of different tendon types (T-tibialis anterior, P-peroneus longus), sterilization methods (G-gamma irradiation of 21 kGy, E-electron beam irradiation of 21 kGy) and storage times (5 and 6 months) on the creep behavior, which is characterized by the strain at the end of the loading phase and creep deformation after static loading. Static creep tests were performed with 250 N load during 60 s. Deformation at the end of the loading phase of both tendons was significantly smaller after 5 months long storage than that after 6 months long storage. TE5 showed significantly less creep than group TE6, and TE6 significantly greater than PE6. The creep of TE5 was significantly lower than that of TG5. Based on the data, the peroneus longus sterilized by electron beam and stored deep frozen for 5 months is a better choice for anterior cruciate ligament reconstruction than tibialis anterior sterilized by gamma irradiation stored for 6 months.
Collapse
Affiliation(s)
- Daniella Judit Gökler
- Budapest University of Technology and Economics, Faculty of Mechanical Engineering, Department of Mechatronics, Optics, and Mechanical Engineering Informatics, Hungary
| | - Dénes Faragó
- Budapest University of Technology and Economics, Faculty of Mechanical Engineering, Department of Mechatronics, Optics, and Mechanical Engineering Informatics, Hungary; Budapest University of Technology and Economics, Faculty of Mechanical Engineering, Biomechanical Research Centre, Hungary
| | - Gábor Szebényi
- Budapest University of Technology and Economics, Faculty of Mechanical Engineering, Biomechanical Research Centre, Hungary; Budapest University of Technology and Economics, Faculty of Mechanical Engineering, Department of Polymer Engineering, Hungary
| | - Rita Mária Kiss
- Budapest University of Technology and Economics, Faculty of Mechanical Engineering, Department of Mechatronics, Optics, and Mechanical Engineering Informatics, Hungary; Budapest University of Technology and Economics, Faculty of Mechanical Engineering, Biomechanical Research Centre, Hungary.
| | - Károly Pap
- Semmelweis University Budapest, Department of Traumatology, Hungary; Uzsoki Hospital, Department of Orthopedics and Traumatology, Hungary
| |
Collapse
|
7
|
Different sterilization and disinfection methods used for human tendons - a systematic review using mechanical properties to evaluate tendon allografts. BMC Musculoskelet Disord 2021; 22:404. [PMID: 33941147 PMCID: PMC8091719 DOI: 10.1186/s12891-021-04296-4] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/03/2021] [Accepted: 04/23/2021] [Indexed: 11/25/2022] Open
Abstract
Background It is important to know the biomechanical properties of an allograft. This is because when looking to do a transplant of a tendon, the tendon must have very similar biomechanical properties to the original tendon. To use tendon allografts, it is critical to properly sterilize the tendon before implantation. In past decades, several sterilization procedures have been used. This study aimed to systematically evaluate the existing literature to compare the values of failure load/ultimate strength and Young’s modulus of elasticity of different sterilization methods on commonly used tendon allografts. Five major scientific literature databases (Web of Science, Science Direct, Scopus, PLOS ONE, Hindawi) and additional sources were used. Results Studies used had to show a particular sterilization method. Studies were identified to meet the following inclusion criteria: is a controlled laboratory study, gamma irradiation (dose reported), and other sterilization methods. Search for publications dated between 1991 and March 31st, 2020. The database search and additional sources resulted in 284 records. Two hundred thirty records eliminated during the screening for various reasons. The number of articles used in the final synthesis was 54. Conclusions Identified sterilization methods (gamma irradiation, ethylene oxid, supercritical carbon dioxide (SCCO2), BioCleanse, Electron Beam) are offered as a catalog of potential methods. As a result of the broadness of the present research, it provides an overview of sterilization methods and their effect on the mechanical properties (failure load and Young’s modulus of elasticity) of tendons. It does not stand for the state-of-the-art of any single process. Based on a systematic literature review, we recommend freezing and gamma irradiation or electron beam at 14.8–28.5 kGy. These methods are effective at keeping or improving the mechanical properties, while fully sterilizing the inside and the outside of the tendon. Other sterilization method (ethylene oxide, supercritical carbon dioxide (SCCO2), BioCleanse) deteriorated the mechanical properties. These methods are not recommended. Supplementary Information The online version contains supplementary material available at 10.1186/s12891-021-04296-4.
Collapse
|
8
|
Sherifi I, Bachy M, Laumonier T, Petite H, Hannouche D. Use of supercritical carbon dioxide technology for fabricating a tissue engineering scaffold for anterior cruciate ligament repair. Sci Rep 2020; 10:14030. [PMID: 32820218 PMCID: PMC7441384 DOI: 10.1038/s41598-020-70994-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2018] [Accepted: 08/04/2020] [Indexed: 01/05/2023] Open
Abstract
Tissue-engineered grafts may be useful in Anterior Cruciate Ligament (ACL) repair and provide a novel, alternative treatment to clinical complications of rupture, harvest site morbidity and biocompatibility associated with autografts, allografts and synthetic grafts. We successfully used supercritical carbon dioxide (Sc-CO2) technology for manufacturing a “smart” biomaterial scaffold, which retains the native protein conformation and tensile strength of the natural ACL but is decellularized for a decreased immunogenic response. We designed and fabricated a new scaffold exhibiting (1) high tensile strength and biomechanical properties comparable to those of the native tissue, (2) thermodynamically-stable extra-cellular matrix (ECM), (3) preserved collagen composition and crosslinking, (4) a decellularized material milieu with potential for future engineering applications and (5) proven feasibility and biocompatibility in an animal model of ligament reconstruction. Because of the “smart” material ECM, this scaffold may have the potential for providing a niche and for directing stem cell growth, differentiations and function pertinent to new tissue formation. Sc-CO2-related technology is advanced and has the capability to provide scaffolds of high strength and durability, which sustain a lifetime of wear and tear under mechanical loading in vivo.
Collapse
Affiliation(s)
- Ines Sherifi
- Laboratoire de Bioingénierie et Biomécanique Ostéo-Articulaire (B2OA), UMR, CNRS 7052, Paris 7 University, Paris, France.,Division of Cardiology, Department of Medicine, Weill Cornell Medical College, New York Presbyterian Hospital, New York, NY, USA
| | - Manon Bachy
- Laboratoire de Bioingénierie et Biomécanique Ostéo-Articulaire (B2OA), UMR, CNRS 7052, Paris 7 University, Paris, France.,Department of Pediatric Orthopaedic Surgery, AP-HP, Hôpital Trousseau, Paris, France
| | - Thomas Laumonier
- Department of Orthopaedic Surgery, Faculty of Medicine, Geneva University Hospitals, Avenue Gabrielle Perret Gentil 4, 1205, Geneva, Switzerland
| | - Hervé Petite
- Laboratoire de Bioingénierie et Biomécanique Ostéo-Articulaire (B2OA), UMR, CNRS 7052, Paris 7 University, Paris, France
| | - Didier Hannouche
- Laboratoire de Bioingénierie et Biomécanique Ostéo-Articulaire (B2OA), UMR, CNRS 7052, Paris 7 University, Paris, France. .,Department of Orthopaedic Surgery, Faculty of Medicine, Geneva University Hospitals, Avenue Gabrielle Perret Gentil 4, 1205, Geneva, Switzerland.
| |
Collapse
|
9
|
Amelia F, Abbas B, Darwis D, Estuningsih S, Noviana D. Effects of bone types, particle sizes, and gamma irradiation doses in feline demineralized freeze-dried bone allograft. Vet World 2020; 13:1536-1543. [PMID: 33061224 PMCID: PMC7522947 DOI: 10.14202/vetworld.2020.1536-1543] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2020] [Accepted: 06/09/2020] [Indexed: 11/16/2022] Open
Abstract
Background and Aim: Fracture cases significantly increase recently, demanding high quality of bone graft materials. This research aimed to evaluate the effects of bone types, particle sizes, and gamma irradiation doses on morphological performance and cell viability of feline demineralized freeze-dried bone allograft (DFDBA) through an in vitro study. Materials and Methods: Feline DFDBA derived from feline cortical and cancellous long bones was processed into four different sizes: Group A (larger than 1000 µm), B (841-1000 µm), C (420-840 µm), and D (250-419 µm) for each type of bones. The materials were then irradiated with two doses of gamma rays, 15 and 25 kGy, resulting in 16 variants of feline DFDBA. The surfaces of each material were then observed with the scanning electron microscope (SEM). The in vitro evaluation of feline DFDBA was then performed using 3-(4,5-dimethythiazol-2)-2,5-diphenyltetrazolium bromide (MTT) assay with calf pulmonary artery endothelial cells. Results: The MTT assay results showed that the lowest inhibition rate (14.67±9.17 %) achieved by feline DFDBA in Group A derived from cortical bones irradiated with 15 kGy. Group D generally showed high inhibition rate in both cancellous and cortical bones, irradiated with either 15 or 25 kGy. The SEM results showed that cancellous and cortical bones have numerous macropores and micropores structure in 170× and 3000×, respectively. Conclusion: The material derived from cortical bones in Group A (larger than 1000 µm in particle size) irradiated with 15 kGy is the best candidate for further development due to its abundance of micropores structure and ability in preserving the living cells.
Collapse
Affiliation(s)
- Frizky Amelia
- Program Study of Animal Biomedical Science, Graduate School of IPB University, Bogor, Jawa Barat 16680, Indonesia.,Diagnostic Imaging Center, Veterinary Teaching Hospital, Faculty of Veterinary Medicine IPB University, Bogor, Jawa Barat 16680, Indonesia
| | - Basril Abbas
- Centre for Isotopes and Radiation Application, National Nuclear Energy Agency (BATAN), Jakarta Selatan, DKI Jakarta 12440, Indonesia
| | - Darmawan Darwis
- Centre for Isotopes and Radiation Application, National Nuclear Energy Agency (BATAN), Jakarta Selatan, DKI Jakarta 12440, Indonesia
| | - Sri Estuningsih
- Department of Clinic Reproduction and Pathology, Faculty of Veterinary Medicine IPB University, Bogor, Jawa Barat 16680, Indonesia
| | - Deni Noviana
- Diagnostic Imaging Center, Veterinary Teaching Hospital, Faculty of Veterinary Medicine IPB University, Bogor, Jawa Barat 16680, Indonesia.,Department of Clinic Reproduction and Pathology, Faculty of Veterinary Medicine IPB University, Bogor, Jawa Barat 16680, Indonesia
| |
Collapse
|
10
|
Biomechanical considerations are crucial for the success of tendon and meniscus allograft integration-a systematic review. Knee Surg Sports Traumatol Arthrosc 2019; 27:1708-1716. [PMID: 30291394 DOI: 10.1007/s00167-018-5185-y] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/13/2018] [Accepted: 09/27/2018] [Indexed: 01/20/2023]
Abstract
PURPOSE This systematic review intends to give an overview of the current knowledge on how allografts used for the reconstruction of cruciate ligaments and menisci are integrated and specifically perform regarding their biomechanical function. METHODS Two reviewers reviewed the PubMed and Central Cochrane library with focus on the biomechanical integration of tendon ligament and meniscus allografts. The literature search was conducted in accordance with the PRISMA statement for reporting systematic reviews and meta-analyses. RESULTS The analysed literature on tendon allografts shows that they are more vulnerable to overstretching in the phase of degradation compared to autografts as the revascularization process starts later and takes longer. Therefore, to avoid excessive graft loads, allografts for cruciate ligament replacement should be selected that exhibit much higher failure loads than the native ligaments to counteract the detrimental effect of degradation. Further, placement techniques should be considered that result in a minimum of strain differences during knee joint motion, which is best achieved by near-isometric placement. The most important biomechanical parameters for meniscus allograft transplantation are secure fixation and proper graft sizing. Allograft attachment by bone plugs or by a bone block is superior to circumferential suturing and enables the allograft to restore the chondroprotective biomechanical function. Graft sizing is also of major relevance, because too small grafts are not able to compensate the knee joint incongruity and too large grafts may fail due to extrusion. Only adequate sizing and fixation together can lead to a biomechanically functioning allograft. The objective assessment of the biomechanical quality of allografts in a clinical setting is challenging, but would be highly desirable for monitoring the remodelling and incorporation process. CONCLUSIONS Currently, indicators like ap-stability after ACL reconstruction or meniscal extrusion represent only indirect measures for biomechanical graft integration. These parameters are at best clinical indicators of allograft function, but the overall integration properties comprising e.g. fixation and graft stiffness remain unknown. Therefore, future research should e.g. focus on advanced imaging techniques or other non-invasive methods allowing for in vivo assessment of biomechanical allograft properties.
Collapse
|
11
|
Aynardi M, Zahoor T, Mitchell R, Loube J, Feltham T, Manandhar L, Paudel S, Schon L, Zhang Z. Orthotopic Transplantation of Achilles Tendon Allograft in Rats: With or without Incorporation of Autologous Mesenchymal Stem Cells. Cell Transplant 2019; 27:245-255. [PMID: 29637821 PMCID: PMC5898692 DOI: 10.1177/0963689717745891] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022] Open
Abstract
The biology and function of orthotopic transplantation of Achilles tendon allograft are unknown. Particularly, the revitalization of Achilles allograft is a clinical concern. Achilles allografts were harvested from donor rats and stored at -80 °C. Subcutaneous adipose tissue was harvested from the would-be allograft recipient rats for isolation of mesenchymal stem cells (MSCs). MSCs were cultured with growth differentiation factor-5 (GDF-5) and applied onto Achilles allografts on the day of transplantation. After the native Achilles tendon was resected from the left hind limb of the rats, Achilles allograft, with or without autologous MSCs, was implanted and sutured with calf muscles proximally and calcaneus distally. Animal gait was recorded presurgery and postsurgery weekly. The animals were sacrificed at week 4, and the transplanted Achilles allografts were collected for biomechanical testing and histology. The operated limbs had altered gait. By week 4, the paw print intensity, stance time, and duty cycle (percentage of the stance phase in a step cycle) of the reconstructed limbs were mostly recovered to the baselines recorded before surgery. Maximum load of failure was not different between Achilles allografts, with or without MSCs, and the native tendons. The Achilles allograft supplemented with MSCs had higher cellularity than the Achilles allograft without MSCs. Deposition of fine collagen (type III) fibers was active in Achilles allograft, with or without MSCs, but it was more evenly distributed in the allografts that were incubated with MSCs. In conclusion, orthotopically transplanted Achilles allograft healed with host tissues, regained strength, and largely restored Achilles function in 4 wk in rats. It is therefore a viable option for the reconstruction of a large Achilles tendon defect. Supplementation of MSCs improved repopulation of Achilles allograft, but large animal models, with long-term follow up and cell tracking, may be required to fully appreciate the functional benefits of MSCs.
Collapse
Affiliation(s)
| | | | - Reed Mitchell
- 3 MedStar Union Memorial Hospital, Baltimore, MD, USA
| | - Jeffrey Loube
- 3 MedStar Union Memorial Hospital, Baltimore, MD, USA
| | | | | | | | - Lew Schon
- 3 MedStar Union Memorial Hospital, Baltimore, MD, USA
| | - Zijun Zhang
- 3 MedStar Union Memorial Hospital, Baltimore, MD, USA
| |
Collapse
|
12
|
D'Lima DD, Il Lee K, Soo Lee J, Tak Kang K, Bock Shim Y, Sik Kim Y, Woong Jang J, Hwan Moon S. In Vitro and In Vivo Performance of Tissue-Engineered Tendons for Anterior Cruciate Ligament Reconstruction: Response. Am J Sports Med 2018; 46:NP61-NP63. [PMID: 30280931 DOI: 10.1177/0363546518800696] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
|