1
|
Ciais G, Tibbo M, Massin V, Barret H, Abdellaoui M, Dardenne T, Winter M, Ricón J, Antoni M, Laumonerie P. Short- to midterm outcomes of 139 pyrocarbon monopolar radial head arthroplasties. J Shoulder Elbow Surg 2024:S1058-2746(24)00550-0. [PMID: 39128647 DOI: 10.1016/j.jse.2024.06.018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/28/2024] [Revised: 05/31/2024] [Accepted: 06/24/2024] [Indexed: 08/13/2024]
Abstract
BACKGROUND The MoPyc radial head arthroplasty (RHA) is a monopolar implant with a pyrocarbon head that obtains rigid fixation via controlled expansion of the titanium stem. The aim of this study was to evaluate the short-term to midterm outcomes of MoPyc RHA. MATERIALS AND METHODS Between 2002 and 2021, 139 MoPyc RHA were implanted in 139 patients with a RH fracture. The mean follow-up was 5.9 years ± 3.5 (range 1-16). Range of motion, mean Mayo Elbow Performance Score (MEPS), Quick Disabilities of the Arm, Shoulder and Hand score, visual analog scale (VAS), radiographic outcome, and reason for failure were recorded. RESULTS The mean MEP, Quick Disabilities of the Arm, Shoulder and Hand, and VAS scores were 89.1 ± 2.2 (range, 45-100), 17.5 ± 16.7 (range, 0-78), and 0.8 ± 1.6 (range, 0-50), respectively. Stress shielding (SS) and osteolysis around the stem were identified in 92 (66%) and 20 (14%) patients. A total of 47 (29%) patients experienced at least 1 complication and 29 (21%) of them required re-intervention. Persistent stiffness (n = 12; 9%) was the most common complication. No painful loosening was noted. Osteolysis around the stem, presence of an autoexpanding stem, and overstuffing were associated with a lower MEPS and an increase in VAS (P < .05). SS was associated with an increase in MEPS (adjusted beta coefficients= 6.92; P < .001) and lower VAS (adjusted beta coefficients= -0.69; P = .016). The autoexpending stem increased the likelihood of SS after RHA (adjusted odds ratio = 1.49; P = .001). CONCLUSIONS A well-fixed MoPyc RHA provided satisfactory short to midterm outcomes, without painful loosening. However, the autoexpanding stem system was associated with poorer functional outcomes and increased the likelihood of SS.
Collapse
Affiliation(s)
- Gregoire Ciais
- Department of Orthopedic Surgery, Clinique Jouvenet, Paris, France
| | - Meagan Tibbo
- Department of Orthopedic Surgery, Mayo Clinic, Phoenix, AZ, USA
| | - Valentin Massin
- Department of Orthopedic Surgery, La Timone Hospital, Marseille, France
| | - Hugo Barret
- Department of Orthopedic Surgery, Pierre Paul Riquet hospital, Toulouse, France
| | | | - Theopol Dardenne
- Department of Orthopedic Surgery, Pellegrin Hospital, Bordeaux, France
| | - Mathias Winter
- Department of Orthopedic Surgery, Saint-Jean Clinic, Cannes, France
| | - Javier Ricón
- Department of Orthopedic Surgery, Vega Baja, Orihuela, Portugal
| | - Maxime Antoni
- Department of Orthopedic Surgery, Clinique de L'orangerie, Strasbourg, France
| | | |
Collapse
|
2
|
Streck M, Vlček M, Veigl D, Pech J, Landor I. [Radial Head Replacement: Management of Elbow and Forearm Instability after Comminuted Radial Head Fractures Associated with Elbow Dislocation]. ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA 2024; 91:96-102. [PMID: 38801665 DOI: 10.55095/achot2024/012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2024]
Abstract
PURPOSE OF THE STUDY This manuscript aims to identify an indication algorithm for the surgical treatment of radial head fractures associated with elbow dislocation. The study compares the mid-term functional outcomes of patients with multifragment radial head fracture treated by resection with the outcomes of patients treated with radial head replacement. MATERIAL AND METHODS The cohort of 34 patients who sustained a radial head fracture at the mean age of 42.5 years (age range 20-81 years) was broken down into two groups by type of surgery. The EXT group consists of 20 patients with the radial head fracture treated by radial head resection. The END group includes 14 patients treated with the radial head replacement. In all patients, the radial head fracture was associated with elbow dislocation (type IV fracture according to the Mason-Johnston classification). The modified Kocher's surgical approach was used in all patients of both the groups. In the EXT group, resection of the fragmented radial head was performed. In the END group, the ExploR® Modular Radial Head System (Zimmer, Biomet, USA) was used, consisting of a CoCr (cobalt chromium) alloy head and a titanium stem. The pain and the range of motion of the elbow and forearm were evaluated after the completion of the outpatient rehabilitation (the mean follow-up period was 2.4 years). Simultaneously, the elbow joint stability was assessed. Radiographs were taken to detect heterotopic ossifications, proximalization of the radius, and any signs of prosthesis loosening. The frequency of reoperations was followed-up. The MEPS (Mayo Elbow Performance Score) was calculated. RESULTS In the EXT group, the mean elbow flexion was 117.5° and the mean pronation/supination was 166.9°. In 50% of patients, the MEPS obtained was greater than 90 points, which means an excellent functional outcome. In 1 patient (5%), recurrent elbow dislocation occurred which was the reason for revision surgery (elbow transfixation with the Kirschner wires and medial collateral ligament suture). Revision surgery was also performed in 2 patients (10%) in whom not all the radial head fragments were removed. Moreover, also observed was elbow joint instability (2 patients) and temporary radial nerve paralysis (1 patient). In 1 case discrete proximalization of the radius developed. The patients in the END group showed the mean elbow flexion of 112° and the mean pronation/supination of 135°. The MEPS obtained from 69% of patients was greater than 90 points, which means an excellent outcome. The pain under load was reported by 3 patients (21%). In 5 patients (35%), the X-rays showed radiolucent zone around the stem of the prosthesis. Neither revision surgery, nor prosthesis removal has been performed yet in any patient. No instability, neurological complications or infections have been reported. In both EXT and END group heterotopic ossifications have developed in 4 patients. CONCLUSIONS Radial head replacement compared to the radial head resection in the management of multifragment fractures associated with elbow dislocations increase the elbow and forearm stability. The group of patients with an implanted radial head prosthesis shows a higher percentage of patients achieving excellent functional outcome than the group of patients with radial head resection. KEY WORDS radial head, elbow, fracture, dislocation, resection, prosthesis.
Collapse
Affiliation(s)
- M Streck
- I. chirurgická klinika hrudní, břišní a úrazové chirurgie Všeobecné fakultní nemocnice a 1. lékařské fakulty Univerzity Karlovy, Praha
| | - M Vlček
- I. ortopedická klinika 1. lékařské fakulty Univerzity Karlovy a Fakultní nemocnice v Motole, Praha
| | - D Veigl
- I. ortopedická klinika 1. lékařské fakulty Univerzity Karlovy a Fakultní nemocnice v Motole, Praha
| | - J Pech
- I. ortopedická klinika 1. lékařské fakulty Univerzity Karlovy a Fakultní nemocnice v Motole, Praha
| | - I Landor
- I. chirurgická klinika hrudní, břišní a úrazové chirurgie Všeobecné fakultní nemocnice a 1. lékařské fakulty Univerzity Karlovy, Praha
- I. ortopedická klinika 1. lékařské fakulty Univerzity Karlovy a Fakultní nemocnice v Motole, Praha
| |
Collapse
|
3
|
Diez Sánchez B, Barco R, Antuña SA. Radial head replacement for acute complex elbow instability: a long-term comparative cohort study of 2 implant designs. J Shoulder Elbow Surg 2023; 32:2581-2589. [PMID: 37619928 DOI: 10.1016/j.jse.2023.07.023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/18/2023] [Revised: 07/11/2023] [Accepted: 07/21/2023] [Indexed: 08/26/2023]
Abstract
BACKGROUND Radial head fractures not amenable to reconstruction should be treated by radial head replacement (RHR) when there is associated elbow or forearm instability. There are multiple RHR designs with different philosophies, but 2 of the most commonly used implants include the anatomic press-fit radial head system and the loose-fit metallic spacer. There is little information available specifically comparing the long-term clinical and radiographic outcomes of these 2 systems. The objective of this study was to compare the long-term clinical and radiologic outcomes of 2 RHR designs in the context of complex acute elbow instability. MATERIALS AND METHODS Ninety-five patients with an average age of 54 years (range, 21-87 years) underwent an acute RHR (46 press-fit Acumed anatomic and 49 loose-fit Evolve metallic spacer) and were prospectively followed for an average of 61 months (range, 24-157 months). There were 34 terrible triads; 36 isolated RH fractures with medial, lateral, or longitudinal instability; and 25 RH fractures associated with a proximal ulnar fracture. Clinical outcome and disability were evaluated with the Mayo Elbow Performance Score (MEPS), the Oxford Elbow Score, and the Disabilities of the Arm, Shoulder, and Hand (DASH) score. Pain and satisfaction were assessed using a visual analog scale. Radiographic analysis included presence of loosening, bone loss, and overstuffing related to the RHR. RESULTS Eight patients with an anatomic RHR (2 with overstuffing, 3 for stiffness, and 3 with loose implants) and 1 patient with a spacer (with stiffness) required implant removal. There were no significant differences between spacer RHR and anatomic RHR in arc of motion (120° vs. 113°, P = .14), pain relief (1 vs. 1.7, P = .135), MEPS (94 vs. 88; P = .07), Oxford Elbow Score (42.3 vs. 42.2, P = .4), or DASH score (12.2 vs. 14.4, P = .5). However, patients with a spacer RHR were significantly more satisfied (9 vs. 7.7; P = .004) than those with an anatomic implant. Radiographically, 19 anatomic implants had significant proximal bone loss and 10 showed complete lucent lines around the stem. Lucent lines were common around the spacer RHR. These radiographic changes were not always related to worse clinical outcomes. CONCLUSION Both the anatomic and spacer RHR designs can provide good clinical long-term outcomes. However, patients with a spacer showed a higher degree of satisfaction and those with an anatomic press-fit RHR had a higher revision rate, with radiographic changes that warrant continued follow-up.
Collapse
Affiliation(s)
| | - Raúl Barco
- Upper Limb Unit, Hospital Universitario La Paz, Madrid, Spain
| | - Samuel A Antuña
- Upper Limb Unit, Hospital Universitario La Paz, Madrid, Spain.
| |
Collapse
|
4
|
Romeo PV, Papalia AG, Alben MG, Halpern J, Ferati SR, Larose G, Singh H, Virk MS. 90-day outcomes and factors for complications following radial head arthroplasty for Mason Type III and IV radial head fractures. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY & TRAUMATOLOGY : ORTHOPEDIE TRAUMATOLOGIE 2023; 33:3099-3106. [PMID: 37029835 DOI: 10.1007/s00590-023-03532-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Accepted: 03/20/2023] [Indexed: 06/19/2023]
Abstract
PURPOSE The aim of this study is to evaluate 90-day outcomes and complications following radial head arthroplasty (RHA) for Mason Type III and IV radial head fractures (RHFs) and determine factors predisposing patients to early complications and revision surgery. METHODS Patients undergoing RHA for Mason Type III and IV RHFs were identified retrospectively from an institutional database. Postoperative complications, reoperations, elbow range of motion, radiographs and concomitant injuries on the ipsilateral upper extremity were reviewed. Additionally, injuries were sub-classified as low-energy trauma (LET) or high-energy trauma (HET). Univariate logistic regression was performed to evaluate the risk for complications using patient factors not limited to the presence of concomitant ligamentous or bony injuries. P values < 0.05 were considered statistically significant. RESULTS Seventy four patients were included in our study with an average follow-up time of 12.7 months. Complications within 90-days of operation occurred in 8.1% of patients: heterotopic ossification (4.1%), superficial wound dehiscence (2.7%), and posterior interosseous nerve palsy (1.4%). No patients required readmission or revision surgery in the 90-day postoperative period. Univariate regression analysis did not demonstrate a significant association between diabetes, ASA status, HET versus LET, or the presence of concomitant injury. Concomitant injuries were found in 92% of patients. CONCLUSION Radial head arthroplasty for RHFs demonstrates a low complication rate in the short-term. Diabetes, ASA class, high versus low energy trauma, and presence of concomitant injury were not found to be associated with higher complication rates in the 90-day postoperative period. LEVEL OF EVIDENCE Level of evidence IV, retrospective case series.
Collapse
Affiliation(s)
- Paul V Romeo
- Division of Shoulder and Elbow Surgery, Department of Orthopedic Surgery, NYU Grossman School of Medicine, NYU Langone Orthopedic Hospital, NYU Langone Health, 246 East 20th Street, New York, NY, 10003, USA
| | - Aidan G Papalia
- Division of Shoulder and Elbow Surgery, Department of Orthopedic Surgery, NYU Grossman School of Medicine, NYU Langone Orthopedic Hospital, NYU Langone Health, 246 East 20th Street, New York, NY, 10003, USA
| | - Matthew G Alben
- Division of Shoulder and Elbow Surgery, Department of Orthopedic Surgery, NYU Grossman School of Medicine, NYU Langone Orthopedic Hospital, NYU Langone Health, 246 East 20th Street, New York, NY, 10003, USA
| | - Joshua Halpern
- Division of Shoulder and Elbow Surgery, Department of Orthopedic Surgery, NYU Grossman School of Medicine, NYU Langone Orthopedic Hospital, NYU Langone Health, 246 East 20th Street, New York, NY, 10003, USA
| | - Sehar Resad Ferati
- Division of Shoulder and Elbow Surgery, Department of Orthopedic Surgery, NYU Grossman School of Medicine, NYU Langone Orthopedic Hospital, NYU Langone Health, 246 East 20th Street, New York, NY, 10003, USA
| | - Gabriel Larose
- Division of Shoulder and Elbow Surgery, Department of Orthopedic Surgery, NYU Grossman School of Medicine, NYU Langone Orthopedic Hospital, NYU Langone Health, 246 East 20th Street, New York, NY, 10003, USA
| | - Hartej Singh
- Division of Shoulder and Elbow Surgery, Department of Orthopedic Surgery, NYU Grossman School of Medicine, NYU Langone Orthopedic Hospital, NYU Langone Health, 246 East 20th Street, New York, NY, 10003, USA
| | - Mandeep S Virk
- Division of Shoulder and Elbow Surgery, Department of Orthopedic Surgery, NYU Grossman School of Medicine, NYU Langone Orthopedic Hospital, NYU Langone Health, 246 East 20th Street, New York, NY, 10003, USA.
| |
Collapse
|
5
|
van Bussel EM, Lindenhovius AL, The B, Eygendaal D. Silicone radial head prostheses revisited: do they have a role in today's practice? A systematic review of literature on clinical outcomes. Clin Shoulder Elb 2023; 26:312-322. [PMID: 37088881 PMCID: PMC10497923 DOI: 10.5397/cise.2022.00990] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2022] [Revised: 10/21/2022] [Accepted: 10/27/2022] [Indexed: 02/11/2023] Open
Abstract
BACKGROUND Silicone radial head prostheses (SRHP) are considered obsolete due to reports of frequent failure and destructive silicone-induced synovitis. Considering the good outcomes of modern non-radial silicone joint implants, the extent of scientific evidence for this negative view is unclear. The aim of this research was to systematically analyze the clinical evidence on complications and outcomes of SRHP and how SRHP compare to both non-SRHP and silicone prostheses of other joints. METHODS A systematic literature review was conducted through the Cochrane, PubMed, and Embase databases. RESULTS Eight cohort studies were included, consisting of 142 patients and follow-up periods ranging from 23 months to 8 years. Average patient satisfaction was 86%, range of 71%-100%, and 58 complications were seen, but no cases of synovitis. These outcomes were in line with non-SRHP. Four case series with 11 cases of synovitis were found, all due to implant fractures years to decades after implantation. Six systematic reviews of currently used non-radial silicone joint implants showed excellent outcomes with low complication rates. CONCLUSIONS Since SRHP have satisfactory clinical results and an acceptable complication rate when selecting a patient group in suitable condition for surgical indications, it is considered that SRHP can still be chosen as a potential surgical treatment method in current clinical practice.
Collapse
Affiliation(s)
- Erik M van Bussel
- Department of Orthopedic Surgery UMC Utrecht, University of Utrecht, Utrecht, The Netherlands
- Department of Orthopedic Surgery, Amphia Hospital, Breda, The Netherlands
| | | | - Bertram The
- Department of Orthopedic Surgery, Amphia Hospital, Breda, The Netherlands
| | - Denise Eygendaal
- Department of Orthopedic Surgery, Amphia Hospital, Breda, The Netherlands
- Department of Orthopedic Surgery, Erasmus University Hospital, Rotterdam, The Netherlands
| |
Collapse
|
6
|
Efficacy and safety of monopolar versus bipolar radial head arthroplasty: a systematic review and meta-analysis. J Shoulder Elbow Surg 2022; 31:646-655. [PMID: 34861403 DOI: 10.1016/j.jse.2021.10.037] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/20/2021] [Revised: 10/08/2021] [Accepted: 10/23/2021] [Indexed: 02/01/2023]
Abstract
BACKGROUND Radial head replacement is the main line of treating complex unstable elbow injuries. Radial head prostheses are either monopolar or bipolar. The difference between both designs in patients' clinical outcomes and postoperative complications is not yet clear. So, a systematic review and meta-analysis was conducted to evaluate the efficacy and safety of monopolar vs. bipolar implants. MATERIALS AND METHODS PubMed, EMBASE, Cochrane, and Scopus were searched to identify studies comparing monopolar and bipolar implants. Data on clinical outcomes, postoperative complications, revision, and removal rates were extracted. RESULTS Nine studies met our inclusion criteria, with a total of 591 patients (365 monopolar and 226 bipolar). Both prostheses achieved similar ranges of motion; Mayo Elbow Performance Score; Disabilities of the Arm, Shoulder, and Hand score; and visual analog scale for pain. Incidence of postoperative complications was also similar between both designs. Revision and removal rates were 24%, 8% and 29%, 14% for monopolar and bipolar implants, respectively, but no statistically significant difference could be detected. CONCLUSIONS No significant difference was found between monopolar and bipolar radial head prostheses in terms of efficacy and safety. Therefore, high-quality randomized controlled trials are required to determine the superiority of one design over the other.
Collapse
|
7
|
Macken AA, Prkić A, Koenraadt KLM, van Oost I, Spekenbrink-Spooren A, The B, Eygendaal D. A registry study on radial head arthroplasties in the Netherlands: Indications, types and short-term survival. Shoulder Elbow 2022; 14:96-102. [PMID: 35154411 PMCID: PMC8832694 DOI: 10.1177/1758573220987843] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/12/2020] [Revised: 12/15/2020] [Accepted: 12/17/2020] [Indexed: 02/03/2023]
Abstract
BACKGROUND This study aims to use the Dutch Arthroplasty Register data to report an overview of the contemporary indications and implant designs, and report the short-term survival of radial head arthroplasty. METHODS From the Dutch Arthroplasty Register, data on patient demographics, surgery and revision were extracted for radial head arthroplasties performed from January 2014 to December 2019. Implant survival was calculated using the Kaplan-Meier method. RESULTS Two hundred fifty-eight arthroplasties were included with a median follow-up of 2.2 years. The most common indication was a fracture of the radial head (178, 69%). One hundred thirty-nine (68%) of the prostheses were of bipolar design, and the most commonly used implant type was the Radial Head System (Tornier; 134, 51%). Of the 258 included radial head arthroplasties, 16 were revised at a median of six months after surgery. Reason for revision was predominantly aseptic loosening (9). The overall implant survival was 95.8% after one year, 90.5% after three years and 89.5% after five years. DISCUSSION For radial head arthroplasties, acute trauma is the most common indication and Radial Head System the most commonly used implant. The implant survival is 89.5% after five years.
Collapse
Affiliation(s)
- Arno A Macken
- Department of Orthopedic Surgery, Amphia Hospital, Breda, the Netherlands,Arno A Macken, Molengracht 21, Breda 4800 RK, the Netherlands.
| | - Ante Prkić
- Department of Orthopedic Surgery, Amphia Hospital, Breda, the Netherlands
| | - Koen LM Koenraadt
- Foundation for Orthopedic Research, Care and Education (FORCE), Amphia Hospital, Breda, the Netherlands
| | - Iris van Oost
- Foundation for Orthopedic Research, Care and Education (FORCE), Amphia Hospital, Breda, the Netherlands
| | | | - Bertram The
- Department of Orthopedic Surgery, Amphia Hospital, Breda, the Netherlands
| | - Denise Eygendaal
- Department of Orthopedic Surgery, Amphia Hospital, Breda, the Netherlands,Department of Orthopedic Surgery, Amsterdam University Medical Centres, Amsterdam, the Netherlands
| |
Collapse
|
8
|
Long-Term Outcomes of Radial Head Arthroplasty in Complex Elbow Fracture Dislocation. J Clin Med 2021; 10:jcm10163488. [PMID: 34441783 PMCID: PMC8397011 DOI: 10.3390/jcm10163488] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2021] [Revised: 07/29/2021] [Accepted: 08/02/2021] [Indexed: 11/16/2022] Open
Abstract
The purpose of the current study was to investigate the long-term outcomes of radial head arthroplasty in complex elbow injuries through radiographic analysis and functional correlation. We evaluated 24 radial head arthroplasties in 24 consecutive patients with complex elbow fracture dislocation. All patients were treated with a single type of modular monopolar prosthesis containing smooth stem in press-fit implantation. Clinical survey using the Mayo Elbow Performance Score (MEPS), self-reported scales of shortened Disabilities of the Arm, Shoulder, and Hand (QuickDASH) and the visual analog scale (VAS) at more than 10-year follow-up were reported and compared to 2-year outcomes. Periprosthetic osteolysis was measured in the 10 zones of prosthesis-cortical interface with a modified radiolucency score, which was calibrated by each prosthesis size. Pearson correlation analysis was performed to detect the association between periprosthetic radiolucency and clinical assessment. At the final follow-up, MEPS, QuickDASH score and VAS score averaged 82.5 ± 15, 14.1 ± 14.3 and 1.6 ± 1.2 respectively. A decline in functional status was noted, with decreased mean MEPS and increased mean QuickDASH and VAS scores as compared to the 2-year results while the difference was insignificant. Periprosthetic osteolysis was more prevalent around stem tip of zone 3 and zone 8. The final and 2-year radiolucency scores averaged 7.4 ± 4.2 and 2.6 ± 2.3 respectively with significant difference. Pearson correlation analysis indicated that the difference between radiolucency scores and clinical outcomes in MEPS/QuickDASH/VAS was -0.836, 0.517 and 0.464. Progression of periprosthetic osteolysis after postoperative 10 years is more prevalent around the stem tip with moderate to high correlation to clinical outcomes. Sustained follow-up is warranted to justify subsequent surgery for revision or implant removal.
Collapse
|
9
|
Lobo-Escolar L, Abellán-Miralles C, Escolà-Benet A. Outcomes of press-fit radial head arthroplasty following complex radial head fractures. Orthop Traumatol Surg Res 2021; 107:102645. [PMID: 32768276 DOI: 10.1016/j.otsr.2020.03.031] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/26/2018] [Revised: 01/24/2020] [Accepted: 03/02/2020] [Indexed: 02/03/2023]
Abstract
INTRODUCTION Press-fit radial head arthroplasty (RHA) is increasingly popular in treating complex radial head fractures. This study assessed the outcome of RHA, including the outcome following re-operation, and explored potentially influencing factors. HYPOTHESIS Complex radial head fractures treated with press-fit radial head prosthesis would have a favourable outcome. MATERIAL AND METHODS Data on all consecutive patients treated with anatomic press-fit RHA from February 2002 to February 2015 were analysed. Post-surgery clinical and X-rays assessments included a post-discharge evaluation of function. Standardised methods implemented include the assessment of range of motion (ROM), the Mayo Elbow Performance Score (MEPS) and subjective satisfaction scales. RESULTS Forty-five patients were recruited and 71% were classified in Mason IV and 62.2% had the "terrible triad". Re-operation was performed in 26.7% and prosthesis removal in 15.6%. Mean follow-up was 140.8 months (95% CI 117.7-164) and prosthesis survival was 69.5% at 24 months. Mean MEPS before re-operations was 86.3±15.9. Pain and/or instability were the most common reasons for re-operation, and re-operations were significantly more frequent in patients having one or more "associated injuries" (p=0.05), but not the terrible triad; and in patients with radiological "loosening" signs (p<0.01). Subjective scores were relatively good in most patients, although the functionality perceived in the re-operation with implant removal group was rather low. DISCUSSION Several studies of complex radial head fractures treated with press-fit radial head prosthesis have also shown favourable results, but the patients in such studies generally had less severe lesions. Moreover, differently from previous reports, this study with a long follow-up has included a younger population with high functionality requirements. Pain and/or instability, as observed in several previous reports, were the most common reasons for re-operation, but contrary to the expectation, the terrible triad was not associated with unfavourable outcome. CONCLUSION Treatment of complex fractures with press-fit radial head prosthesis, including re-operation with implant removal yields satisfactory results. Most scores of functional and subjective outcome improved following the re-intervention and most patients returned to their usual occupation. LEVEL OF EVIDENCE Level IV; case series; treatment study.
Collapse
Affiliation(s)
- Luis Lobo-Escolar
- Department of Orthopaedics & Traumatology Surgery, Hospital Asepeyo Sant Cugat, Sant Cugat, Barcelona, Spain; Autonomous University of Barcelona, Barcelona, Spain.
| | - César Abellán-Miralles
- Department of Orthopaedics & Traumatology Surgery, Hospital Asepeyo Sant Cugat, Sant Cugat, Barcelona, Spain
| | - Anna Escolà-Benet
- Department of Orthopaedics & Traumatology Surgery, Hospital Universitario General de Cataluña, Sant Cugat, Barcelona, Spain
| |
Collapse
|
10
|
Antoni M, Ginot G, Mereb T, Clement X, Eichler D, Kempf JF, Clavert P. Post-traumatic elbow osteoarthritis after radial head arthroplasty: Prevalence and risk factors. Orthop Traumatol Surg Res 2021; 107:102814. [PMID: 33482405 DOI: 10.1016/j.otsr.2021.102814] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/09/2019] [Revised: 03/02/2020] [Accepted: 03/18/2020] [Indexed: 02/03/2023]
Abstract
BACKGROUND One of the treatment options for comminuted radial head fractures is radial head arthroplasty (RHA), especially when the elbow is also dislocated. While the clinical outcomes of RHA have been well documented, the incidence of post-traumatic osteoarthritis after RHA and its risk factors are not well known. OBJECTIVE To determine the incidence of post-traumatic elbow osteoarthritis (humeroulnar and humeroradial joints) after RHA and identify its risk factors. METHODS All patients who underwent RHA at our hospital between 2008 and 2016 were included retrospectively. The inclusion criteria were primary RHA, recent radial head fracture (isolated or associated with elbow dislocation), minimum 1 year of follow-up, clinical and radiographic examination at final assessment. The exclusion criteria were pre-existing elbow osteoarthritis, RHA revision, multiple fractures of the ipsilateral upper limb or polytrauma. The final assessment consisted of a clinical examination [joint range of motion (ROM) and Mayo Elbow Performance Score (MEPS)] and standard radiographs. The correlation between the incidence and severity of osteoarthritis and various risk factors was determined. RESULTS Seventy-three patients were included in the analysis with a mean age of 56 years (21-85). The injuries consisted of 41 terrible triad, 15 isolated radial head fractures, 11 Monteggia fractures and 6 transolecranon fracture-dislocations. The mean follow-up was 3.4 years (1-10.9). At the final assessment, osteoarthritis was visible in the humeroulnar compartment in 56% of cases and in the humeroradial compartment in 72% of cases. There was a statistical correlation between the presence of humeroulnar osteoarthritis at the final assessment and ROM in flexion-extension (p=0.003), MEPS (p<0.001), duration of immobilization (p=0.03) and presence of posterior subluxation on immediate postoperative radiographs (p=0.012). The correlation between humeroradial osteoarthritis at the final assessment and ROM in flexion-extension (p=0.0054), RHA implant position (p<0.01), and unipolar configuration (p=0.027) was statistically significant. CONCLUSION In our study, elbow osteoarthritis incidence after RHA was 56% in the humeroulnar joint and 72% in the humeroradial joint. RHA implant placement, posterior subluxation immediately postoperative and the duration of immobilization were significantly corelated with osteoarthritis. LEVEL OF EVIDENCE IV; case series without control group.
Collapse
Affiliation(s)
- Maxime Antoni
- Service de Chirurgie du Membre Supérieur, Pôle de Chirurgie Orthopédique et de Traumatologie, Hôpital Hautepierre 2 - CHU Strasbourg, Avenue Molière, 67000 Strasbourg, France.
| | - Geoffrey Ginot
- Service de Chirurgie du Membre Supérieur, Pôle de Chirurgie Orthopédique et de Traumatologie, Hôpital Hautepierre 2 - CHU Strasbourg, Avenue Molière, 67000 Strasbourg, France
| | - Thomas Mereb
- Service de Chirurgie du Membre Supérieur, Pôle de Chirurgie Orthopédique et de Traumatologie, Hôpital Hautepierre 2 - CHU Strasbourg, Avenue Molière, 67000 Strasbourg, France
| | - Xavier Clement
- Service de Chirurgie du Membre Supérieur, Pôle de Chirurgie Orthopédique et de Traumatologie, Hôpital Hautepierre 2 - CHU Strasbourg, Avenue Molière, 67000 Strasbourg, France
| | - David Eichler
- Service de Chirurgie du Membre Supérieur, Pôle de Chirurgie Orthopédique et de Traumatologie, Hôpital Hautepierre 2 - CHU Strasbourg, Avenue Molière, 67000 Strasbourg, France
| | - Jean-François Kempf
- Service de Chirurgie du Membre Supérieur, Pôle de Chirurgie Orthopédique et de Traumatologie, Hôpital Hautepierre 2 - CHU Strasbourg, Avenue Molière, 67000 Strasbourg, France
| | - Philippe Clavert
- Service de Chirurgie du Membre Supérieur, Pôle de Chirurgie Orthopédique et de Traumatologie, Hôpital Hautepierre 2 - CHU Strasbourg, Avenue Molière, 67000 Strasbourg, France
| |
Collapse
|
11
|
Chen ACY, Weng CJ, Chiu CH, Chang SS, Cheng CY, Chan YS. Retrospective cohort study on radial head arthroplasty comparing long-term outcomes between valgus type injury and fracture dislocation. BMC Musculoskelet Disord 2020; 21:763. [PMID: 33218325 PMCID: PMC7678050 DOI: 10.1186/s12891-020-03767-4] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/03/2020] [Accepted: 11/03/2020] [Indexed: 12/13/2022] Open
Abstract
Background Radial head arthroplasty (RHA) has been commonly adopted for irreparable radial head fractures while little information is addressed on valgus type injury. The purpose of this study is to report long-term outcomes and radiographic analysis in RHA for valgus type injury with comparison to fracture dislocation injury. Methods A retrospective cohort study was conducted in patients receiving unilateral RHA with loose-fit, modular metal prosthesis for irreparable radial head fractures between 2004 and 2012. Totally, 33 patients with a mean follow up of 9 years (range, 7 to 15 years) were enrolled and divided into two groups including 14 valgus injuries and 19 fracture-dislocations. Demographics of the patients, injury details, clinical and radiographic outcomes, and correlation analysis were investigated and compared between two groups. Results In patient demographics, significant difference was noted in sex distribution (p = 0.001), lateral collateral ligament involvement (p = 0.000) and time from injury to RHA (p = 0.031) between two groups. No patient underwent subsequent removal or revision of prosthesis. Good to excellent results according to Mayo Elbow Performance Score (MEPS) was achieved in 13 and 14 patients in group A and B respectively. Final motion range and Disabilities of the Arm, Shoulder, and Hand score was significantly better in valgus injury group. Radiographic analysis demonstrated fewer patients in valgus injury group presented periprosthetic osteolysis with weak to moderate negative correlation between radiolucency score and MEPS. Conclusions With an average of 9 years follow-up, RHA using loose-fit, modular metal prosthesis achieves encouraging outcomes for both valgus injury and fracture dislocation. In valgus type injury, better motion range, lower disability score and lower incidence of periprosthetic osteolysis is noted while correlation analysis of radiolucency score suggests extended, long-term investigation.
Collapse
Affiliation(s)
- Alvin Chao-Yu Chen
- Bone and Joint Research Center, Department of Orthopaedic Surgery, Chang Gung Memorial Hospital-Linkou and Chang Gung University College of Medicine, 5th, Fu-Shin Street, Kweishan District, Taoyuan, 333, Taiwan, ROC.
| | - Chun-Jui Weng
- Bone and Joint Research Center, Department of Orthopaedic Surgery, Chang Gung Memorial Hospital-Linkou and Chang Gung University College of Medicine, 5th, Fu-Shin Street, Kweishan District, Taoyuan, 333, Taiwan, ROC
| | - Chih-Hao Chiu
- Bone and Joint Research Center, Department of Orthopaedic Surgery, Chang Gung Memorial Hospital-Linkou and Chang Gung University College of Medicine, 5th, Fu-Shin Street, Kweishan District, Taoyuan, 333, Taiwan, ROC
| | - Shih-Sheng Chang
- Bone and Joint Research Center, Department of Orthopaedic Surgery, Chang Gung Memorial Hospital-Linkou and Chang Gung University College of Medicine, 5th, Fu-Shin Street, Kweishan District, Taoyuan, 333, Taiwan, ROC
| | - Chun-Ying Cheng
- Bone and Joint Research Center, Department of Orthopaedic Surgery, Chang Gung Memorial Hospital-Linkou and Chang Gung University College of Medicine, 5th, Fu-Shin Street, Kweishan District, Taoyuan, 333, Taiwan, ROC
| | - Yi-Sheng Chan
- Bone and Joint Research Center, Department of Orthopaedic Surgery, Chang Gung Memorial Hospital-Linkou and Chang Gung University College of Medicine, 5th, Fu-Shin Street, Kweishan District, Taoyuan, 333, Taiwan, ROC
| |
Collapse
|
12
|
Bergmann M, El-Barbari J, Porschke F, Grützner PA, Guehring T, Schnetzke M. Reliability of dynamic fluoroscopy for medial elbow stability in the presence of radial head resection. ACTA ACUST UNITED AC 2020. [DOI: 10.1007/s11678-020-00572-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Abstract
Background
The aim of this study was to examine whether dynamic fluoroscopy is reliable for assessment of medial elbow stability in the presence of radial head resection and different stages of medial collateral ligament (MCL) dissection in a cadaveric elbow model.
Materials and methods
Six intact elbow specimens were measured for joint angulation while applying valgus stress in four examination conditions (Examiner 1, Examiner 2, 1 Nm, 2 Nm) in four different elbow positions (fully pronated or supinated at 0° of elbow extension and 30° of elbow flexion). The elbow specimens were examined for valgus stress in three stages: (1) intact, (2) after radial head resection, and (3) after subsequent dissection of the complete MCL. Anteroposterior radiographs of the elbow were made at each stage to determine joint angulation. Intraclass correlation coefficients (ICCs) were calculated.
Results
In intact elbows, mean joint angulation ranged from 2.2° ± 2.0 (1 Nm) to 5.2° ± 2.3 (Examiner 1). Radial head resection did not increase joint angulation during valgus stress, regardless of joint position and examination condition (Examiner 1: 5.5°; Examiner 2: 5.0°; 1 Nm: 2.6°, 2 Nm: 3.9°). Additional dissection of the MCL led to significantly higher joint angulation during measurements with the standardized torques (1 Nm: 12.4°; 2 Nm: 23.3°). Very good to excellent ICCs for joint angulation between Examiner 1 and Examiner 2 (0.861 to 0.959) were found.
Conclusion
Dynamic fluoroscopy is a reliable diagnostic tool for determining medial elbow stability in the presence of radial head resection and different stages of MCL dissection.
Collapse
|
13
|
Monoblock polyethylene radial head prosthesis for the treatment of unreconstructable acute radial head fractures with a minimum 1-year follow-up: A retrospective case series. CURRENT ORTHOPAEDIC PRACTICE 2020. [DOI: 10.1097/bco.0000000000000849] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|