1
|
Guild GN, McConnell MJ, Najafi F, Naylor BH, DeCook CA, Bradbury TL. Posterior Cruciate Ligament Preservation versus Posterior Cruciate Ligament Sacrifice: Comparing Patient Outcomes in Medial Congruent Total Knee Arthroplasty. J Knee Surg 2024. [PMID: 39102867 DOI: 10.1055/a-2379-6488] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 08/07/2024]
Abstract
This study aimed to compare outcomes and complication rates between posterior cruciate ligament (PCL) retention and excision utilizing a medial congruent (MC) polyethylene insert in total knee arthroplasty (TKA) in a specialized ambulatory surgery center (ASC) dedicated to hip and knee arthroplasty. A retrospective review was performed between May 2023 and October 2023 analyzing 398 patients who underwent primary MC TKA by high-volume joint arthroplasty surgeons (n = 9) with either PCL preservation (n = 264) or sacrifice (n = 134) in a single free-standing ASC. Patients were matched chronologically on a 2:1 basis. Demographics, baseline function, 90-day complications, and patient-reported outcomes were recorded for each patient. There were no differences in preoperative baseline function or patient-reported outcome measures, Charlson Comorbidity Index, or American Society of Anesthesiologists class among patient groups. The PCL-preserve and PCL-sacrifice cohorts showed significant variation in 12-week postoperative Knee Injury and Osteoarthritis Outcome, Junior (KOOS, JR.) scores. Specifically, the number of patients who achieved the minimal clinically important difference (MCID) in KOOS, JR. scores was higher in the PCL-sacrifice group (p < 0.05). Yet, no complications within the 90-day period were associated with PCL status and other patient-reported outcomes. This study comparing outcomes between MC TKAs with PCL retention and sacrifice suggests that both techniques are viable options with similar functional outcomes, pain scores, and complication rates, which may have benefits in an ASC setting. The PCL-sacrifice group exhibited a statistically significant increase in patients who achieved the MCID in KOOS, JR. score compared with the PCL-preserving at early follow-up. Future research should employ prospective, randomized designs to further validate these findings and explore long-term implications.
Collapse
Affiliation(s)
- George N Guild
- Total Joint Specialists, LLC, Advanced Center for Joint Surgery and Northside Hospital Forsyth, Cumming, Georgia
| | - Mary J McConnell
- Total Joint Specialists, LLC, Advanced Center for Joint Surgery and Northside Hospital Forsyth, Cumming, Georgia
| | - Farideh Najafi
- Total Joint Specialists, LLC, Advanced Center for Joint Surgery and Northside Hospital Forsyth, Cumming, Georgia
| | - Brandon H Naylor
- Total Joint Specialists, LLC, Advanced Center for Joint Surgery and Northside Hospital Forsyth, Cumming, Georgia
| | - Charles A DeCook
- Total Joint Specialists, LLC, Advanced Center for Joint Surgery and Northside Hospital Forsyth, Cumming, Georgia
| | - Thomas L Bradbury
- Total Joint Specialists, LLC, Advanced Center for Joint Surgery and Northside Hospital Forsyth, Cumming, Georgia
| |
Collapse
|
2
|
Foong BCM, Lee WC, Khoo SKM, Kunnasegaran R. No difference in clinical outcomes when retaining or sacrificing the posterior cruciate ligament in medial congruent total knee replacement. A retrospective study. Musculoskelet Surg 2024:10.1007/s12306-024-00866-6. [PMID: 39231900 DOI: 10.1007/s12306-024-00866-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2024] [Accepted: 08/29/2024] [Indexed: 09/06/2024]
Abstract
PURPOSE The aim of this study is to evaluate the effect of retaining or sacrificing the posterior cruciate ligament (PCL) in patients who undergo primary total knee replacement (TKR) with the medial congruent (MC) implant. METHODS This retrospective study looks at patients who underwent TKR with the MC implant. Comparison was made between the group with the PCL sacrificed (MC-PCLS) and the group with the PCL retained (MC-PCLR). Range of motion (ROM), Oxford knee score (OKS), Knee society knee score (KS-KS) and Knee society function score (KS-FS) were recorded. RESULTS The study identified 76 patients. 50 in the MC-PCLS group and 26 in the MC-PCLR group. Both groups had similar patient demographics. Three months postoperatively, OKS and KS-KS had significant improvement. However, there was significant improvement in KS-FS score in the MC-PCLS group but not the MC-PCLR group (MC-PCLR: 33 ± 17, p = 0.07; MC-PCLS: 19 ± 24, p = 0.01). Twelve months postoperatively, the OKS continued to improve significantly for both groups, while the KS-FS and KS-KS scores appeared to stagnate. The ROM continued to improve significantly for the MC-PCLR group but not the MC-PCLS group (MC-PCLR: 7 ± 9, p = 0.03; MC-PCLS: 4 ± 9, p = 0.30). Both groups were similar in ROM, OKS and KSS scores at both the 3 and 12 month post-operative period. CONCLUSION There is no difference in post-operative outcomes with the PCL retained or sacrificed. As such, surgeons can consider routinely sacrificing the PCL for easier balancing of the knee and shorter surgical time.
Collapse
Affiliation(s)
- B C M Foong
- Department of Orthopaedic Surgery, Tan Tock Seng Hospital, 11 Jalan Tan Tock Seng, Singapore, 308433, Singapore.
| | - W C Lee
- Department of Orthopaedic Surgery, Tan Tock Seng Hospital, 11 Jalan Tan Tock Seng, Singapore, 308433, Singapore
| | - S K M Khoo
- Lee Kong Chian School of Medicine, Nanyang Technological University, 11 Mandalay Road, Singapore, 308232, Singapore
| | - R Kunnasegaran
- Department of Orthopaedic Surgery, Tan Tock Seng Hospital, 11 Jalan Tan Tock Seng, Singapore, 308433, Singapore
| |
Collapse
|
3
|
Cacciola G, Giustra F, Bosco F, Vezza D, Pirato F, Braconi L, Risitano S, Capella M, Massè A, Sabatini L. No significant clinical differences between native or reduced posterior tibial slope in kinematically aligned total knee replacement with posterior cruciate-retaining. J Orthop 2024; 54:32-37. [PMID: 38524363 PMCID: PMC10957378 DOI: 10.1016/j.jor.2024.03.023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/10/2024] [Accepted: 03/13/2024] [Indexed: 03/26/2024] Open
Abstract
Aims & objectives Total knee arthroplasty (TKA) is a common surgical procedure for end-stage knee osteoarthritis. However, conventional alignment techniques may lead to postoperative dissatisfaction in up to 20% of cases. Kinematic alignment (KA) has emerged as a new philosophy to restore the native joint line and achieve more natural kinematics. Preserving the posterior tibial slope (PTS) and posterior cruciate ligament (PCL) is crucial to maintaining the pre-arthritic joint line and improving knee kinematics. This study aimed to assess the prevalence of postoperative PTS changes and their impact on functional outcomes and range of motion. Materials & methods A retrospective single-center study was conducted on patients who underwent KA-TKA with PCL preservation. The preoperative and postoperative PTS were measured on lateral knee radiographs using the tibial proximal anatomic axis method. Patient-reported outcome measures (PROMs) were collected pre- and postoperatively up to a two-year follow-up. Results Of the 95 included patients, 62.1% achieved an anatomically similar PTS (within 3° from the preoperative value), while 37.9% experienced noticeable PTS changes. However, no significant associations existed between PTS changes and compromised PROMs (WOMAC, 22.2 and 23.1; FJS, 66.6 and 67.3), ROM (118.5° and 119.4°), or patient satisfaction. No postoperative complications requiring reoperation or component revisions were observed. Conclusion Preserving or modifying the native PTS during KA-TKA could be confidently undertaken without compromising functional outcomes or patient satisfaction.
Collapse
Affiliation(s)
- Giorgio Cacciola
- Department of Orthopaedics and Traumatology, University of Turin, CTO, Torino, Italy
| | - Fortunato Giustra
- Department of Orthopaedics and Traumatology, San Giovanni Bosco Hospital—ASL Città di Torino, 10154, Turin, Italy
| | - Francesco Bosco
- Department of Precision Medicine in Medical, Surgical and Critical Care (Me.Pre.C.C.), University of Palermo, Palermo, Italy
- Department of Orthopaedics and Traumatology, G.F. Ingrassia Hospital Unit, ASP 6, Palermo, Italy
| | - Daniele Vezza
- Department of Orthopaedics and Traumatology, University of Turin, CTO, Torino, Italy
| | - Francesco Pirato
- Department of Orthopaedics and Traumatology, University of Turin, CTO, Torino, Italy
| | - Lorenzo Braconi
- Department of Orthopaedics and Traumatology, University of Turin, CTO, Torino, Italy
| | - Salvatore Risitano
- Department of Orthopaedics and Traumatology, University of Turin, CTO, Torino, Italy
| | - Marcello Capella
- Department of Orthopaedics and Traumatology, University of Turin, CTO, Torino, Italy
| | - Alessandro Massè
- Department of Orthopaedics and Traumatology, University of Turin, CTO, Torino, Italy
| | - Luigi Sabatini
- Humanitas Gradenigo, Department of Robotic and Minimally-Invasive Arthroplasty Surgery, 10153, Turin, Italy
| |
Collapse
|
4
|
Cowie RM, Cullum CJ, Collins SN, Jennings LM. The wear and kinematics of two medially stabilised total knee replacement systems. Knee 2024; 47:160-170. [PMID: 38394995 DOI: 10.1016/j.knee.2024.01.004] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/20/2023] [Revised: 11/16/2023] [Accepted: 01/18/2024] [Indexed: 02/25/2024]
Abstract
BACKGROUND Medially stabilised total knee replacement systems aim to provide a more natural feeling knee replacement by providing increased stability through flexion. The aim of this study was to compare the kinematics and wear of two different medially stabilised total knee replacement systems in an experimental simulation study. The Medial Rotation Knee™ system (MRK) is an early medially stabilised knee (>20 years clinical success); the SAIPH® knee system being a more modern and refined, bone conserving evolution of the original design with a larger size range. METHODS Three SAIPH and three MRK total knee replacements (MatOrtho Ltd, UK) were investigated. The study was performed on a knee simulator with load controlled input kinematic conditions (ISO 14243-1). 6 million cycles of simulation were carried out with the wear of the UHMWPE tibial components assessed gravimetrically. The resulting anterior-posterior translation and tibial rotation position was measured throughout the study. RESULTS The mean UHMWPE wear rate was 0.57 ± 0.71 and 1.24 ± 2.0 mm3/million cycles for SAIPH and MRK total knee replacement systems respectively with no significant difference in wear (p = 0.24). Analysis of simulator output kinematics showed a larger range of anterior-posterior motion for SAIPH total knee replacements compared to MRK. The magnitude of tibial rotation was low for both knee replacement systems. CONCLUSION The small magnitude of anterior-posterior displacement and tibial rotation motion demonstrates the inherent stability of this knee system design offered by the constrained medial compartment. This study shows the potential for medially stabilised knee systems as a low polyethylene surface wear solution.
Collapse
Affiliation(s)
- Raelene M Cowie
- Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds LS2 9JT, UK.
| | | | | | - Louise M Jennings
- Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds LS2 9JT, UK.
| |
Collapse
|
5
|
Budhiparama NC, Lumban-Gaol I, Novito K, Hidayat H, De Meo F, Cacciola G, Cavaliere P. PCL retained is safe in medial pivot TKA-a prospective randomized trial. Knee Surg Sports Traumatol Arthrosc 2023; 31:5856-5863. [PMID: 37962615 PMCID: PMC10719124 DOI: 10.1007/s00167-023-07634-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/28/2023] [Accepted: 10/09/2023] [Indexed: 11/15/2023]
Abstract
PURPOSE Medial pivot (MP) designs resemble native knee kinematics and restore the "natural" kinematics of a knee after total knee arthroplasty (TKA). However, whether to preserve or resect the posterior cruciate ligament (PCL) is still under debate. We inquired whether sacrificing the PCL would improve range of motion, functional outcomes, and limb alignment compared to preserving the PCL in TKA using medial pivot implants (MP-TKA). METHODS This prospective, double-blinded, randomized controlled trial consisted of 33 patients (66 knees) undergoing bilateral simultaneous MP-TKA. In one knee, a PCL preservation technique was performed, and in the contralateral knee, the PCL was resected. The primary outcome was postoperative range of motion (ROM). The secondary outcomes were visual analogue scale (VAS) score for knee pain at walking, Knee Injury and Osteoarthritis Outcome Score for symptoms (KOOS-S) and quality of life (KOOS-QoL), Oxford knee score (OKS), and Forgotten Joint Score (FJS), and measurement of the mechanical femoral-tibial axis (mFTA) on X-ray images. All patients were followed up for a minimum of 2 years after surgery. RESULTS Patients who underwent MP-TKA with PCL preservation had a similar ROM at 2 years (125.45 ± 7.00 vs. 126.21 ± 6.73, p = 0.65) as those who underwent MP-TKAs with PCL resection. There was also no difference in VAS score (1.94 ± 0.79 vs. 2.00 ± 0.71, respectively, p = 0.51), OKS (39.97 ± 2.01 vs. 39.67 ± 2.03, respectively, p = 0.52), KOOS-S (84.41 ± 3.77 vs. 84.19 ± 3.57, respectively, p = 0.92), KOOS-QoL (82.94 ± 4.76 vs. 82.75 ± 4.70, respectively, p = 0.84), or FJS (72.66 ± 8.99 vs. 72.35 ± 8.64, respectively, p = 0.76) at the 2-year follow-up. No difference in the measurement of the mFTA was found between the two groups (180.27 ± 2.25 vs. 181.30 ± 2.13, respectively, p = 0.59). CONCLUSION This study demonstrated that both medial pivot TKA with PCL preservation and PCL resection achieved excellent results. There was no difference at the 2-year follow-up in terms of postoperative ROM, patient-reported outcomes, or radiographic evaluation. LEVEL OF EVIDENCE Therapeutic study, Level I.
Collapse
Affiliation(s)
- Nicolaas C Budhiparama
- Department of Orthopaedic and Traumatology, Faculty of Medicine, Universitas Airlangga, Surabaya, Indonesia.
- Department of Orthopaedics, Leiden University Medical Centre, Leiden, The Netherlands.
- Nicolaas Institute of Constructive Orthopaedic Research and Education Foundation for Arthroplasty and Sports Medicine at Medistra Hospital, Jakarta, Indonesia.
| | - Imelda Lumban-Gaol
- Nicolaas Institute of Constructive Orthopaedic Research and Education Foundation for Arthroplasty and Sports Medicine at Medistra Hospital, Jakarta, Indonesia
| | - Kiki Novito
- Nicolaas Institute of Constructive Orthopaedic Research and Education Foundation for Arthroplasty and Sports Medicine at Medistra Hospital, Jakarta, Indonesia
| | - Hendy Hidayat
- Nicolaas Institute of Constructive Orthopaedic Research and Education Foundation for Arthroplasty and Sports Medicine at Medistra Hospital, Jakarta, Indonesia
| | - Federico De Meo
- GIOMI Istituto Ortopedico del Mezzogiorno d'Italia Franco Scalabrino, Ganzirri, Via Consolare Pompea, 98165, Messina, ME, Italy
| | - Giorgio Cacciola
- GIOMI Istituto Ortopedico del Mezzogiorno d'Italia Franco Scalabrino, Ganzirri, Via Consolare Pompea, 98165, Messina, ME, Italy
| | - Pietro Cavaliere
- GIOMI Istituto Ortopedico del Mezzogiorno d'Italia Franco Scalabrino, Ganzirri, Via Consolare Pompea, 98165, Messina, ME, Italy
| |
Collapse
|
6
|
Giannotti S, Crippa Orlandi N, Troiano E, Cacioppo M, Giacché T, Greco T, Perisano C, Mondanelli N. Medial Ball-in-Socket Posterior Cruciate-Sacrificing Total Knee Arthroplasty: Clinical, Functional and Radiographic Evaluation of 100 Consecutive Implants. PROSTHESIS 2023; 5:1275-1286. [DOI: 10.3390/prosthesis5040087] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/27/2024]
Abstract
The number of performed total knee arthroplasty (TKA) operations is constantly growing. This study proposes an evaluation of a series of patients undergoing medial pivot (MP) TKA surgery from a subjective, clinical and biomechanical point of view. A consecutive series of 100 TKAs implanted in a single centre, by the same surgeon, with a medial parapatellar approach with the sacrifice of the posterior cruciate ligament and cemented components were evaluated. All patients underwent standardized radiographic and functional clinical evaluation, with standing antero-posterior, lateral and patellar axial views; pre-operatively and post-operatively at 1, 3, 6 and 12 months; and then annually. Results were evaluated using three different patient-related outcome measurement scores (PROMs): the Knee Osteoarthritis Outcome Score (KOOS), the new Knee Society Score (nKSS) and the Short Form Health Survey 36 (SF-36). Excellent results in all treated knees were documented using the PROMs: the mean nKSS was 199.8, the mean KOOS was good to excellent in every subscale, and the mean was SF-36 82%. There were no cases of septic or aseptic loosening, vascular damage, neurological damage, or revision surgery for any reason. According to the experience gained, MP implants demonstrated excellent results, being clinically functional in both objective and subjective terms as well as radiographic evaluations, thus resulting in a winning strategy for obtaining a TKA that makes the patient satisfied and able to perform their daily life activities.
Collapse
Affiliation(s)
- Stefano Giannotti
- Department of Medicine, Surgery and Neurosciences, University of Siena, 53100 Siena, Italy
- Section of Orthopedics, Azienda Ospedaliero-Universitaria Senese, 53100 Siena, Italy
| | - Nicholas Crippa Orlandi
- Department of Medicine, Surgery and Neurosciences, University of Siena, 53100 Siena, Italy
- Section of Orthopedics, Azienda Ospedaliero-Universitaria Senese, 53100 Siena, Italy
| | - Elisa Troiano
- Department of Medicine, Surgery and Neurosciences, University of Siena, 53100 Siena, Italy
- Section of Orthopedics, Azienda Ospedaliero-Universitaria Senese, 53100 Siena, Italy
| | - Matteo Cacioppo
- Department of Medicine, Surgery and Neurosciences, University of Siena, 53100 Siena, Italy
- Section of Orthopedics, Azienda Ospedaliero-Universitaria Senese, 53100 Siena, Italy
| | - Tiziano Giacché
- Department of Medicine, Surgery and Neurosciences, University of Siena, 53100 Siena, Italy
- Section of Orthopedics, Azienda Ospedaliero-Universitaria Senese, 53100 Siena, Italy
| | - Tommaso Greco
- Orthopedics and Trauma Surgery Unit, Department of Ageing, Neurosciences, Head-Neck and Orthopedics Sciences, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Rome, Italy
| | - Carlo Perisano
- Orthopedics and Trauma Surgery Unit, Department of Ageing, Neurosciences, Head-Neck and Orthopedics Sciences, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Rome, Italy
| | - Nicola Mondanelli
- Department of Medicine, Surgery and Neurosciences, University of Siena, 53100 Siena, Italy
- Section of Orthopedics, Azienda Ospedaliero-Universitaria Senese, 53100 Siena, Italy
| |
Collapse
|
7
|
Rajgopal A, Kumar S, Singh MK, Aggarwal K. PCL retention demonstrates better functional scores and gait patterns in total knee arthroplasty using a medial congruent insert-a prospective study. Knee Surg Sports Traumatol Arthrosc 2023; 31:4741-4746. [PMID: 37393561 DOI: 10.1007/s00167-023-07499-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Accepted: 06/21/2023] [Indexed: 07/04/2023]
Abstract
PURPOSE Despite Total Knee Arthroplasty (TKA) being one of the most successful procedures for end stage arthritis, nearly 20% of patients undergoing this procedure remain dissatisfied. Various design options have been introduced to reduce this cohort of patients. One such option has been the introduction of the medial congruent (MC) polyethylene design. This study was undertaken to evaluate outcome measures and gait analysis in patients undergoing bilateral single stage TKA where the posterior cruciate ligament (PCL) was retained or excised in contralateral knees. METHODS 60 bilateral TKA's were performed by a single surgeon using a MC design option from July to Sep 2021. The study lots included patients between the ages of 55 and 70 years with fixed varus deformity of degenerative aetiology, and Kellgren Lawrence Grade 3 and 4 radiological changes. Exclusion criteria were previous surgery to the lower extremities, sero positive arthropathies, post traumatic arthritis, valgus deformity, flexion contractures > 20°, and any pre-existing pathology impacting gait, e.g., poliomyelitis, or neuromuscular disorders. The PCL was retained or sacrificed on contralateral sides for the purpose of this study. Functional scores, outcomes and gait analysis on level and gradient walking were evaluated at a follow-up of 18 months. RESULTS At 18, months the Range of Motion (ROM) improved from a preoperative value of 97.3 ± 11.5 to 110.3 ± 6.1 on the PCL retained side (MC-PCL) and from 96.5 ± 10.8 to 113 ± 5.8 on the PCL excised side (MC-PCLX). Knee Society Score (KSS-2011) improved from a preoperative value of 21.2 ± 4.5 to 89.8 ± 3.4 at 18 months postoperatively on the MC-PCL side and from 21.5 ± 4 to 88.2 ± 3.7 on the MC-PCLX side. Forgotten Joint Score (FJS-12) was 8.8 ± 0.7 on the MC-PCL side and 8.1 ± 0.9 on the MC-PCLX side 18 months after surgery. Our gait analysis evaluation demonstrated a lower forefoot pressure in the MC-PCL group in comparison to the MC-PCLX group when subjects were made to walk on a 30° upward incline. This difference was found to be statistically significant. CONCLUSION In this study, while ROM was greater in the MC-PCLX study lot, patient satisfaction was higher in the MC-PCL study lot. Gait assessment demonstrated lower forefoot pressure while ascending an incline of 30° in the MC-PCL study lot as compared to the MC-PCLX study lot approximating normal gait patterns. LEVEL OF EVIDENCE II.
Collapse
Affiliation(s)
- Ashok Rajgopal
- Medanta- The Medicity Hospital, Gurugram, Haryana, 122001, India.
| | - Sumit Kumar
- Medanta- The Medicity Hospital, Gurugram, Haryana, 122001, India
| | | | - Kalpana Aggarwal
- Medanta- The Medicity Hospital, Gurugram, Haryana, 122001, India
| |
Collapse
|
8
|
Movassaghi K, Patel A, Ghulam-Jelani Z, Levine BR. Modern Total Knee Arthroplasty Bearing Designs and the Role of the Posterior Cruciate Ligament. Arthroplast Today 2023; 21:101130. [PMID: 37151403 PMCID: PMC10160699 DOI: 10.1016/j.artd.2023.101130] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/02/2023] [Revised: 02/04/2023] [Accepted: 03/08/2023] [Indexed: 05/09/2023] Open
Abstract
The role of the posterior cruciate ligament (PCL) in total knee arthroplasty (TKA) surgery continues to be a source of debate among the adult reconstruction community. In native knee flexion, the PCL is comprised of an anterolateral and posteromedial bundle that work together to limit posterior tibial translation and allow adequate femoral rollback for deep flexion. In the arthritic knee, the PCL can often become dysfunctional and attenuated, which led to the development of posterior stabilized (PS) TKA bearing options. PS TKAs implement a cam-post construct to functionally replace a resected PCL. While PS designs may facilitate balancing knees with significant deformity, they are associated with complications such as postfracture, increased wear, and patellar clunk/crepitus. In recent years, newer designs have been popularized with greater degrees of congruency and incorporation of medial and lateral pivoting to better recreate native knee kinematics. The American Joint Registry has confirmed the recent predilection for ultra-congruent and cruciate-retaining TKA inserts over PS TKAs during the last decade. Studies have failed to identify an overall clinical superiority between the cruciate substituting and sacrificing designs. The literature has also failed to identify clinical consequences from PCL resection with modern, more conforming TKA designs. In this article, we review modern PCL sacrificing designs and discuss the impact of each on the kinematics after TKA. We also will delineate the role of the PCL in modern TKA in the hopes to better understand the recent surge in sacrificing but not substituting knee implants.
Collapse
Affiliation(s)
- Kamran Movassaghi
- Department of Orthopaedic Surgery, University of California, San Francisco Fresno, Fresno, CA, USA
- Corresponding author. University of California, San Francisco Fresno, 2823 Fresno Street, Fresno, CA 93721, USA. Tel.: +1 818 640 5244.
| | - Arpan Patel
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Zohal Ghulam-Jelani
- Department of Orthopaedic Surgery, University of California, San Francisco Fresno, Fresno, CA, USA
| | - Brett R. Levine
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA
| |
Collapse
|
9
|
Risitano S, Cacciola G, Capella M, Bosco F, Giustra F, Fusini F, Indelli PF, Massé A, Sabatini L. Comparison between gaits after a medial pivot and posterior stabilized primary total knee arthroplasty: a systematic review of the literature. ARTHROPLASTY 2023; 5:15. [PMID: 36927464 PMCID: PMC10022170 DOI: 10.1186/s42836-023-00165-8] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2022] [Accepted: 01/16/2023] [Indexed: 03/18/2023] Open
Abstract
BACKGROUND Total knee arthroplasty (TKA) is one of the most performed orthopedic procedures worldwide. While excellent efficacy has been reported, about 20% of patients are not satisfied with the result. A potential cause is the problematic reproduction of knee kinematics. This systematic review examines gait analysis studies in primary medial pivot (MP) and posterior stabilized (PS) TKAs to investigate the differences between the two prosthesis designs. METHODS A systematic review was conducted by following PRISMA guidelines. Five databases (PubMed, Medline, Embase, Scopus and the Cochrane Database of Systematic Reviews) were analyzed, and eligible articles were evaluated in terms of the levels of evidence. The methodological quality of the articles was assessed by using the MINORS scoring. This review was registered in PROSPERO. RESULTS Nine studies were included. Gait analysis was performed in 197 MP TKA and 192 PS TKA patients. PS TKA cases showed (P < 0.05) a significantly higher peak of knee flexion angle during the swing phase, greater knee flexion angle at toe-off, an increased knee adduction angle, higher knee flexion and extension moment, increased anterior femoral roll during knee flexion and anterior translation on medial and lateral condyle during knee flexion compared to MP TKA. MP TKA showed statistically significant (P < 0.05) higher knee rotational moment and greater tibiofemoral external rotation motion during knee flexion than PS TKA. No statistically significant difference (P > 0.05) was reported regarding gait spatial-temporal parameters. The Forgotten Joint Score (FJS) and Western Ontario and McMaster Universities Comparison in terms of Arthritis Index (WOMAC) score (mean stiffness) showed that MP TKA yielded significantly better results than PS TKA. CONCLUSIONS This systematic review revealed significant kinematic and kinetic differences between MP and PS TKA at all gait analysis phases. Furthermore, the considerable difference between TKA design and the kinematics of healthy knee were highlighted in this study. LEVEL OF EVIDENCE III.
Collapse
Affiliation(s)
- Salvatore Risitano
- Department of Orthopaedic Surgery and Traumatology, University of Turin, 10126, Turin, Italy.
- Department of Orthopaedic Surgery and Traumatology, CTO Hospital of Turin, Città Della Salute E Della Scienza, 10126, Turin, Italy.
| | - Giorgio Cacciola
- Department of Orthopaedic Surgery and Traumatology, University of Turin, 10126, Turin, Italy
| | - Marcello Capella
- Department of Orthopaedic Surgery and Traumatology, University of Turin, 10126, Turin, Italy
- Department of Orthopaedic Surgery and Traumatology, CTO Hospital of Turin, Città Della Salute E Della Scienza, 10126, Turin, Italy
| | - Francesco Bosco
- Department of Orthopaedic Surgery and Traumatology, University of Turin, 10126, Turin, Italy
- Department of Orthopaedics and Traumatology, Ospedale San Giovanni Bosco-ASL Città di Torino, Piazza del Donatore Di Sangue, 3, 10154, Turin, Italy
| | - Fortunato Giustra
- Department of Orthopaedic Surgery and Traumatology, University of Turin, 10126, Turin, Italy
- Department of Orthopaedics and Traumatology, Ospedale San Giovanni Bosco-ASL Città di Torino, Piazza del Donatore Di Sangue, 3, 10154, Turin, Italy
| | - Federico Fusini
- Department of Orthopaedic Surgery, Regina Montis Regalis Hospital, 12084, MondovìCuneo, Italy
| | - Pier Francesco Indelli
- Department of Orthopaedic Surgery and Bioengineering, Stanford University School of Medicine, Palo Alto Veterans Affairs Health Care System (PAVAHCS), Palo Alto, CA, 94304, USA
| | - Alessandro Massé
- Department of Orthopaedic Surgery and Traumatology, University of Turin, 10126, Turin, Italy
- Department of Orthopaedic Surgery and Traumatology, CTO Hospital of Turin, Città Della Salute E Della Scienza, 10126, Turin, Italy
| | - Luigi Sabatini
- Department of Orthopaedic Surgery and Traumatology, University of Turin, 10126, Turin, Italy
- Department of Orthopaedic Surgery and Traumatology, CTO Hospital of Turin, Città Della Salute E Della Scienza, 10126, Turin, Italy
| |
Collapse
|
10
|
Hamilton LD, Andreassen TE, Myers CA, Shelburne KB, Clary CW, Rullkoetter PJ. Knee pivot location in asymptomatic older adults. J Biomech 2023; 149:111487. [PMID: 36868041 PMCID: PMC10080542 DOI: 10.1016/j.jbiomech.2023.111487] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2022] [Revised: 01/28/2023] [Accepted: 02/06/2023] [Indexed: 02/11/2023]
Abstract
Representative data of asymptomatic, native-knee kinematics is important when studying changes in knee function across the lifespan. High-speed stereo radiography (HSSR) provides a reliable measure of knee kinematics to <1 mm of translation and 1° of rotation, but studies often have limited statistical power to make comparisons between groups or measure the contribution of individual variability. The purpose of this study is to examine in vivo condylar kinematics to quantify the transverse center-of-rotation, or pivot, location across the flexion range and challenge the medial-pivot paradigm in asymptomatic knee kinematics. We quantified the pivot location during supine leg press, knee extension, standing lunge, and gait for 53 middle-aged and older adults (27 men; 26 women: 50.8 ± 7.0 yrs, 1.75 ± 0.1 m, 79.1 ± 15.4 kg). A central- to medial-pivot location was identified for all activities with increased knee flexion associated with posterior translation of the center-of-rotation. The association between knee angle and anterior-posterior center-of-rotation location was not as strong as the relation between medial-lateral and anterior-posterior location, excluding gait. The Pearson's correlation for gait was stronger between knee angle and anterior-posterior center-of-rotation location (P < 0.001) than medial-lateral and anterior-posterior location (P = 0.0122). Individual variability accounted for a measurable proportion in variance explained of center-of-rotation location. Unique to gait, the lateral translation of center-of-rotation location resulted in the anterior translation of center-of-rotation at <10° knee flexion. Furthermore, no association between vertical ground-reaction force and center-of-rotation was identified.
Collapse
Affiliation(s)
| | | | - Casey A Myers
- University of Denver, Denver, CO, USA; Ortho Haus, LLC, CO, USA
| | | | - Chadd W Clary
- University of Denver, Denver, CO, USA; Ortho Haus, LLC, CO, USA
| | | |
Collapse
|
11
|
No Significant Differences in Clinical and Radiographic Outcomes between PCL Retained or Sacrificed Kinematic Aligned Medial Pivot Total Knee Arthroplasty in Varus Knee. J Clin Med 2022; 11:jcm11216569. [PMID: 36362796 PMCID: PMC9658241 DOI: 10.3390/jcm11216569] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Revised: 10/29/2022] [Accepted: 11/02/2022] [Indexed: 11/09/2022] Open
Abstract
In the last decades, several surgical techniques, such as medial pivot (MP) philosophy and kinematic alignment (KA), have been introduced in total knee arthroplasty (TKA) to improve patients’ outcomes. This retrospective study aims to evaluate the clinical, radiographic, and functional results of PCL preservation or sacrifice in KA MP-TKA. A consecutive series of 147 patients older than 60, with a minimum follow-up of two years, were treated with TKA for severe primary knee osteoarthritis (OA) at the Department of Orthopedics and Traumatology between 1 January 2019, and 1 July 2020. After excluding those not meeting the inclusion criteria, 64 patients were included in the study analysis. Regarding radiographic outcomes, no statistically significant difference was observed between patients with preserved or sacrificed PCL (p > 0.05). A slight improvement in Knee Society Score (KSS), knee and function score, and FJS was observed for the PCL-preserved group, although this superiority tendency was not statistically significant (p > 0.05). PCL-preserved MA MP-TKA reported a statistically significant result in only two questions on the FJS questionnaire (p < 0.05). A slight, non-statistically significant improvement in active ROM was found in the PCL-sacrificed group (p > 0.05). No interventions or revisions were reported in this case series for all treated patients at the final follow-up. No significant differences were described in clinical, radiographic, and functional outcomes in preserved or sacrificed PCL KA MP-TKA. Although not significant, a slight trend toward better clinical outcomes was reported in PCL-preserved KA MP-TKA.
Collapse
|
12
|
Tang S, Zheng L, Luo Y, Wu R, Tian Q, Wang L. Validation of an MRI Technique for the 6-DOF Knee Kinematics Measurement. Front Bioeng Biotechnol 2022; 10:904012. [PMID: 36601392 PMCID: PMC9806800 DOI: 10.3389/fbioe.2022.904012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2022] [Accepted: 06/09/2022] [Indexed: 01/07/2023] Open
Abstract
Background: For total knee arthroplasty (TKA), the optimal rotational position of the femoral component is felt to be critically important. The current knee joint kinematics measurement technology is unable to identify the exact rotation axis of the knee joint, the main reasons being low measurement accuracy and insufficient three-dimensional data (2D-3D image matching technology). In order to improve the effect of TKA surgery, we proposed a knee joint kinematics measurement method, based on the MRI technology, and verified its measurement accuracy. We then employed this method to identify the personalized optimal rotation axis of the knee joint for TKA patients. Purposes: The purpose of the study was 1) to propose a method for measuring knee joint kinematics and verify its accuracy and 2) to propose a method for determining the optimal rotation axis of knee joint for TKA surgery, based on accurate kinematic measurement results. Materials and Methods: The experiment was divided into two parts: in vitro and in vivo. The purpose of the in vitro experiment was to verify the measurement accuracy of our method. We fixed two aquarium stones (approximately 10 cm * 10 cm * 10 cm in size, close to the size of the distal femur and proximal tibia) firmly on the fixed and moving arms of the goniometer/vernier caliper with glue and immersed the aquarium stones in the water to capture MRI images. The MRI images were then processed with MATLAB software, and the relative motion of the two aquarium stones was measured. The measurement accuracy of our method was verified via the scale reading of the moving arm on the goniometer/vernier caliper. In vivo, 36 healthy elderly participants (22 females, 14 males) were recruited from the local community; our method was then employed to measure the relative motion of the tibia and femur and to observe the rollback and screw home motion of the medial/lateral condyle of the femur, which was identified as specific kinematic features of the knee joint. Results: In vitro, all measurements were accurate to <1 mm and <1°. In vivo, all knee measurements showed rollback motion (the rollback distance of the medial femoral condyle was 18.1 ± 3.7 mm and that of the lateral condyle was 31.1 ± 7.3 mm) and screw home motion. Conclusion: In the application scenario of knee joint kinematics measurement, our method has an accuracy of <1° of rotation angle and <1 mm of translation for all reference points, and it can be employed to identify the most stable axis of the knee joint. Significance: Using our method to accumulate data on the knee rotation axis of more subjects to establish an average rotation axis of a given population may help in knee prosthesis design and reduce the patient dissatisfaction rate. Individually measuring the patient's rotation axis before TKA surgery and adjusting the prosthesis installation in TKA may further reduce the patient dissatisfaction rate, and automatic computer measurement may be realized in the future, but it is still time-consuming for now.
Collapse
Affiliation(s)
- Shixiong Tang
- Department of Radiology, The Second Xiangya Hospital, Central South University, Changsha, China,Clinical Research Center for Medical Imaging in Hunan Province, Changsha, China
| | - Liwen Zheng
- Department of Rehabilitation, The Second Xiangya Hospital, Central South University, Changsha, China,*Correspondence: Liwen Zheng,
| | - Yongheng Luo
- Department of Radiology, The Second Xiangya Hospital, Central South University, Changsha, China
| | - Ren Wu
- Department of Orthopedics, The Second Xiangya Hospital, Central South University, Changsha, China
| | - Qunyan Tian
- Department of Orthopedics, The Second Xiangya Hospital, Central South University, Changsha, China
| | - Lei Wang
- School of Information Science and Engineering, Central South University, Changsha, China
| |
Collapse
|
13
|
Risitano S, Cacciola G, Sabatini L, Capella M, Bosco F, Giustra F, Massè A, Vaishya R. Restricted kinematic alignment in primary total knee arthroplasty: A systematic review of radiographic and clinical data. J Orthop 2022; 33:37-43. [PMID: 35812351 PMCID: PMC9263746 DOI: 10.1016/j.jor.2022.06.014] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/06/2022] [Accepted: 06/29/2022] [Indexed: 01/16/2023] Open
Abstract
Introduction Kinematic alignment (KA) has increased in popularity in recent years, becoming a viable alternative to MA with encouraging short- and mid-term follow-up results. Recently, the concept of restricted kinematic alignment (rKA) has been developed to restore native knee kinematics better, avoiding failure of coronal alignment. This systematic review aims to examine whether rKA improves outcome scores (PROMs) compared with MA and to evaluate the radiographic analysis of the lower limb alignment and the causes of complications and reoperations with the rKA approach. Methods A systematic literature search was conducted following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines on the Pubmed/Medline, Scopus, Cochrane Library, and Embase databases. The following key terms were used: "restricted kinematic alignment, rKA, kinematic alignment, primary total knee arthroplasty, primary total knee replacement, TKA rKA, and TKR rKA." The initial screening identified 328 studies. Each eligible article was evaluated according to the inclusion criteria: studies with levels of evidence (LoE) 1 to 4, written in English, published through May 2022, and involving human subjects. Criteria from the Methodological Index for Non-Randomized Studies (MINORS) were used to assess the methodological quality of the articles. Results Six clinical studies were included in this systematic review. The study was registered in the International Prospective Registry of Systematic Reviews (PROSPERO). A total of 574 knees were included. After excluding patients due to loss of follow-up or missing data, 475 knees were analyzed. The following rKA-related data were evaluated: patient-reported outcome scores (PROMs), radiographic analysis of the lower limb alignment, and causes of complications and reoperations. Conclusions The rKA is an improved concept for restoring native knee kinematics, avoiding excessive coronal varus/valgus alignment. It provides equivalent or slightly better PROMs than MA without increasing the risk of short-middle-term implant failure. Clinical studies with extended follow-up are needed to confirm this trend.
Collapse
Affiliation(s)
- Salvatore Risitano
- Department of Orthopaedics and Traumatology, University of Turin, CTO, Turin, Italy
| | - Giorgio Cacciola
- Department of Orthopaedics and Traumatology, University of Turin, CTO, Turin, Italy
| | - Luigi Sabatini
- Department of Orthopaedics and Traumatology, University of Turin, CTO, Turin, Italy
| | - Marcello Capella
- Department of Orthopaedics and Traumatology, University of Turin, CTO, Turin, Italy
| | - Francesco Bosco
- Department of Orthopaedics and Traumatology, University of Turin, CTO, Turin, Italy
| | - Fortunato Giustra
- Department of Orthopaedics and Traumatology, University of Turin, CTO, Turin, Italy
| | - Alessandro Massè
- Department of Orthopaedics and Traumatology, University of Turin, CTO, Turin, Italy
| | | |
Collapse
|
14
|
Stolarczyk A, Maciąg BM, Mostowy M, Maciąg GJ, Stępiński P, Szymczak J, Żarnovsky K, Świercz M, Oleksy Ł, Stolarczyk M. Comparison of Biomechanical Gait Parameters and Patient-Reported Outcome in Patients After Total Knee Arthroplasty With the Use of Fixed-Bearing Medial Pivot and Multi-radius Design Implants—Retrospective Matched-Cohort Study. Arthroplast Today 2022; 14:29-35. [PMID: 35128014 PMCID: PMC8799913 DOI: 10.1016/j.artd.2021.10.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/27/2021] [Revised: 09/28/2021] [Accepted: 10/08/2021] [Indexed: 12/05/2022] Open
Abstract
Background Total knee arthroplasty (TKA) is considered to be highly successful in treatment of end-stage osteoarthritis. There are multiple implant designs available on the market, and it is difficult to point which one is the best. The aim of this study was to compare the clinical and functional outcomes and gait pattern after TKA with the use of fixed-bearing medial pivot (K-Mod) vs multi-radius design (NexGen) implants and to compare them to norms for healthy patients with no osteoarthritis or arthroplasty procedure in anamnesis. Methods A group of 30 patients who received the medial pivot (MP) TKA and 33 patients who received the posterior-stabilized (PS) TKA between May and August of 2018 were included. All surgeries were performed in the level III academic hospital by a single surgeon. Every patient was asked to fulfill the The Western Ontario and McMaster Universities Arthritis Index (WOMAC) questionnaire preoperatively and 2 years postoperatively. Standard X-ray, biomechanical gait analysis using a motion capture system, and statistical analysis were performed at 2 years postoperatively. Results A total of 28 patients from either MP cohort (93%) or PS (85%) matched-control cohort completed the whole assessment at the final follow-up. There were statistically significant differences in a few gait parameters such as shorter mean step length both in operated and healthy limb, lower mean gait velocity, and lower mean walking cadence than the norm in both MP and PS groups. As to the WOMAC score, there was statistically significant improvement in both groups comparing preoperative and postoperative outcomes. Nevertheless, in the MP group, there was a significantly higher score, indicating worse outcomes, in the stiffness part of the WOMAC score than in the PS group. No significant differences were found between groups during radiological evaluation. Conclusions There were satisfying and promising clinical, radiographic, and patient-reported outcomes in both MP and PS groups with very little difference in relation to norm values. However, both implants failed in fully restoring gait patterns similar to the healthy limb of the same patient.
Collapse
|
15
|
Medial stabilised total knee arthroplasty achieves comparable clinical outcomes when compared to other TKA designs: a systematic review and meta-analysis of the current literature. Knee Surg Sports Traumatol Arthrosc 2022; 30:638-651. [PMID: 33247352 PMCID: PMC8866298 DOI: 10.1007/s00167-020-06358-x] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/20/2020] [Accepted: 10/27/2020] [Indexed: 12/26/2022]
Abstract
PURPOSE The purpose of this study was to perform a systematic review and meta-analysis to compare clinical and patient-reported outcome measures of medially stabilised (MS) TKA when compared to other TKA designs. METHODS The Preferred Reporting Items for Systematic Review and Meta-Analyses algorithm was used. The Cochrane Central Register of Controlled Trials, MEDLINE, EMBASE, and EMCARE databases were searched to June 2020. Studies with a minimum of 12 months of follow-up comparing an MS TKA design to any other TKA design were included. The statistical analysis was completed using Review Manager (RevMan), Version 5.3. RESULTS The 22 studies meeting the inclusion criteria included 3011 patients and 4102 TKAs. Overall Oxford Knee Scores were significantly better (p = 0.0007) for MS TKA, but there was no difference in the Forgotten Joint Scores (FJS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Knee Society Score (KSS)-Knee, KSS-Function, and range of motion between MS and non-MS TKA designs. Significant differences were noted for sub-group analyses; MS TKA showed significantly worse KSS-Knee (p = 0.02) and WOMAC (p = 0.03) scores when compared to Rotating Platform (RP) TKA while significantly better FJS (p = 0.002) and KSS-knee scores (p = 0.0001) when compared to cruciate-retaining (CR) TKA. CONCLUSION This review and meta-analysis show that MS TKA designs result in both patient and clinical outcomes that are comparable to non-MS implants. These results suggest implant design alone may not provide further improvement in patient outcome following TKA, surgeons must consider other factors, such as alignment to achieve superior outcomes. LEVEL OF EVIDENCE III.
Collapse
|
16
|
Alessio-Mazzola M, Clemente A, Russo A, Mertens P, Burastero G, Formica M, Felli L. Clinical radiographic outcomes and survivorship of medial pivot design total knee arthroplasty: a systematic review of the literature. Arch Orthop Trauma Surg 2022; 142:3437-3448. [PMID: 34633511 PMCID: PMC9522696 DOI: 10.1007/s00402-021-04210-6] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/01/2020] [Accepted: 09/29/2021] [Indexed: 01/09/2023]
Abstract
BACKGROUND Total knee arthroplasty is a reliable procedure able to reduce pain and disability in patients suffering from osteoarthritis. However, a considerable percentage of patients still experiences unsatisfactory results. Medial pivot total knee arthroplasty has been introduced in the clinical practice to overcome problems related with classic design implants and better mimic native knee kinematics. The aim of this study was to analyze survivorship and clinical and radiographic outcomes of medial pivot implants. METHODS A systematic research was conducted in eight different databases. Thirty-four studies met the inclusion criteria and were included in the analysis. Data on objective and patients-reported outcomes, radiographic alignment, and survivorship were collected and analyzed. Revision rate was expressed as revision per 100 components years. RESULT A total of 3377 procedures were included. Mean follow-up was 85.7 months (range, 12-182). The revision per 100 components years was 0.19, which corresponds to a revision rate of 1.9% after 10 years. Mean post-operative range of motion was 117.3 ± 0.4°. Mean clinical and functional Knee Society Score were, respectively, 85.9 ± 1.1 and 84.7 ± 3.5 at final follow-up. Post-operative femorotibial alignment was 177.1 ± 0.5°. Alfa and beta angles were 95.7 ± 0.1° and 89.2 ± 0.1°, respectively. Gamma and delta angles were 2.3 ± 0.6° and 86.7 ± 0.4°. CONCLUSION Medial pivoting implants provided excellent survivorship and low revision rate, as well as good-to-excellent results in term of objective and patient-reported clinical outcomes, and reliable correction of radiographic parameters. More high-quality studies with long-term follow-up are needed to clarify the role of medial pivoting implants.
Collapse
Affiliation(s)
- Mattia Alessio-Mazzola
- Orthopedic Clinic, Ospedale Policlinico San Martino, Largo R. Benzi 10, 16132, Genoa, Italy.
- Department of Surgical Sciences and Integrated Diagnostic (DISC), University of Genoa, Viale Benedetto XV 6, 16132, Genoa, Italy.
| | - Antonio Clemente
- Orthopedic Clinic, Ospedale Policlinico San Martino, Largo R. Benzi 10, 16132, Genoa, Italy
- Department of Surgical Sciences and Integrated Diagnostic (DISC), University of Genoa, Viale Benedetto XV 6, 16132, Genoa, Italy
| | - Antonio Russo
- Orthopedic Clinic, Ospedale Policlinico San Martino, Largo R. Benzi 10, 16132, Genoa, Italy
- Department of Surgical Sciences and Integrated Diagnostic (DISC), University of Genoa, Viale Benedetto XV 6, 16132, Genoa, Italy
| | - Peter Mertens
- Orthopaedics and Traumatology Department, ZNA Middelheim, Antwerp, Belgium
| | - Giorgio Burastero
- Centro di Chirurgia Protesica, Istituto Ortopedico Galeazzi IRCCS, Via Riccardo Galeazzi 4, 20161, Milan, Italy
| | - Matteo Formica
- Orthopedic Clinic, Ospedale Policlinico San Martino, Largo R. Benzi 10, 16132, Genoa, Italy
- Department of Surgical Sciences and Integrated Diagnostic (DISC), University of Genoa, Viale Benedetto XV 6, 16132, Genoa, Italy
| | - Lamberto Felli
- Istituto Ortopedico Galeazzi IRCCS Chirurgia Articolare Sostitutiva e Chirurgia Ortopedica, Via Riccardo Galeazzi 4, 20161, Milan, Italy
| |
Collapse
|
17
|
Jenny JY, Bercovy M, Cazenave A, Gaillard T, Châtain F, Jolles BE, Rouvillain JL, Saragaglia D. No difference in 13-year survival after medial pivot or central pivot mobile bearing total knee arthroplasty. A propensity matched comparative analysis. Knee Surg Sports Traumatol Arthrosc 2021; 29:3648-3653. [PMID: 33165636 DOI: 10.1007/s00167-020-06355-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/27/2020] [Accepted: 10/26/2020] [Indexed: 11/30/2022]
Abstract
PURPOSE The present study was designed to evaluate the long-term results (more than 10 years) of mobile bearing total knee arthroplasty (TKA) and to compare the survival of medial pivot axis (MPA) and central pivot axis (CPA) TKAs. The primary hypothesis was that the 10- to 15-year survival rate of MPA TKAs will be better than CPA TKAs. METHODS A national, multicenter, retrospective study was performed in France. In this case-control design, 1154 TKAs were paired into the CPA group (control group: 577 cases) and MPA group (study group: 577 cases) based on a logistic regression analysis of age, gender, body mass index and severity of the coronal deformity, defining the propensity score for each case. Final survival information follow-up was obtained for 946 cases (82%). RESULTS There was no significant difference between the control and study groups for any baseline data. Twenty-two prosthetic revisions (2%) were performed for mechanical reasons during the follow-up period. There was no significant difference between the 13-year survival rates of CPA (98%) and MPA (97%) TKAs. There was no significant difference between groups in their final Oxford and Knee Society scores. CONCLUSION Our findings do not support the assumption that medialization of the pivot axis of a mobile bearing TKA improves clinical results or survival. LEVEL OF EVIDENCE Level III.
Collapse
Affiliation(s)
- Jean-Yves Jenny
- University Hospital Strasbourg, CCOM, 10 avenue Baumann, 67400, Illkirch, France.
| | - Michel Bercovy
- Clinique Arago, 187A Rue Raymond Losserand, 75014, Paris, France
| | - Alain Cazenave
- Institut CALOT, Department of Orthopedic Surgery, 52 rue du Dr Calot, 62600, Berck-sur-Mer, France
| | - Thierry Gaillard
- Polyclinique du Beaujolais, 120 Ancienne Route de Beaujeu, 69400, Arnas, France
| | - Frédéric Châtain
- Pole Santé Axone, 75 Avenue Gabriel Péri, 38400, Saint-Martin-d'Hères, France
| | - Brigitt E Jolles
- Swiss BioMotion Lab, Department of Musculoskeletal Medicine, Centre Hospitalier Universitaire Vaudois and University of Lausanne, Avenue Louis-Ruchonnet 57, 1003, Lausanne, Switzerland.,Institute of Micro Engineering, Ecole Polytechnique Fédérale de Lausanne, Route Cantonale, 1015, Lausanne, Switzerland
| | - Jean-Louis Rouvillain
- Department of Orthopaedic and Trauma Surgery, Hôpital Zobda Quitman, 97261, Fort-de-France, France
| | - Dominique Saragaglia
- Department of Osteoarthritis and Sport Surgery, Traumatology of the Limbs, Grenoble-Alpes South Teaching Hospital, 38130, Echirolles, France
| | | |
Collapse
|
18
|
Øhrn FD, Lian ØB, Tsukanaka M, Röhrl SM. Early migration of a medially stabilized total knee arthroplasty : a radiostereometric analysis study up to two years. Bone Jt Open 2021; 2:737-744. [PMID: 34493056 PMCID: PMC8479839 DOI: 10.1302/2633-1462.29.bjo-2021-0115.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
Aims Medial pivot (MP) total knee arthroplasties (TKAs) were designed to mimic native knee kinematics with their deep medial congruent fitting of the tibia to the femur almost like a ball-on-socket, and a flat lateral part. GMK Sphere is a novel MP implant. Our primary aim was to study the migration pattern of the tibial tray of this TKA. Methods A total of 31 patients were recruited to this single-group radiostereometric analysis (RSA) study and received a medial pivot GMK Sphere TKA. The distributions of male patients versus female patients and right versus left knees were 21:10 and 17:14, respectively. Mean BMI was 29 kg/m2 (95% confidence interval (CI) 27 to 30) and mean age at surgery was 63 years (95% CI 61 to 66). Maximum total point motions (MTPMs), medial, proximal, and anterior translations and transversal, internal, and varus rotations were calculated at three, 12, and 24 months. Patient-reported outcome measure data were also retrieved. Results MTPMs at three, 12, and 24 months were 1.0 mm (95% CI 0.8 to 1.2), 1.3 mm (95% CI 0.9 to 1.7), and 1.4 mm (0.8 to 2.0), respectively. The Forgotten Joint Score was 79 (95% CI 39 to 95) and Knee Injury and Osteoarthritis Outcome Score obtained at two years was 94 (95% CI 81 to 100), 86 (95% CI 75 to 93), 94 (95% CI 88 to 100), 69 (95% CI 48 to 88), and 81 (95% CI59 to 100) for Pain, Symptoms, Activities of Daily Living, Sport & Recreation, and Quality of Life, respectively. Conclusion In conclusion, we found that the mean increase in MTPM was lower than 0.2 mm between 12 and 24 months and thus apparently stable. Yet the GMK Sphere had higher migration at one and two years than anticipated. Based on current RSA data, we therefore cannot conclude on the long-term performance of the implant, pending further assessment. Cite this article: Bone Jt Open 2021;2(9):737–744.
Collapse
Affiliation(s)
- Frank-David Øhrn
- Kristiansund Hospital, Møre and Romsdal Health Trust, Kristiansund, Norway.,Department of Neuromedicine and Movement Science, NTNU Norwegian University of Science and Technology, Trondheim, Norway
| | - Øystein Bjerkestrand Lian
- Kristiansund Hospital, Møre and Romsdal Health Trust, Kristiansund, Norway.,Department of Neuromedicine and Movement Science, NTNU Norwegian University of Science and Technology, Trondheim, Norway
| | - Masako Tsukanaka
- Institute of Clinical Medicine, University of Oslo, Oslo, Norway
| | - Stephan Maximillian Röhrl
- Institute of Clinical Medicine, University of Oslo, Oslo, Norway.,Division of Orthopaedic Surgery, Oslo University Hospital, Oslo, Norway
| |
Collapse
|
19
|
Cacciola G, Mancino F, De Meo F, Bruschetta A, De Martino I, Cavaliere P. Current Reconstruction Options in Periprosthetic Fractures Around the Knee. Geriatr Orthop Surg Rehabil 2021; 12:21514593211023996. [PMID: 34471568 PMCID: PMC8404675 DOI: 10.1177/21514593211023996] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/05/2021] [Revised: 04/21/2021] [Accepted: 05/17/2021] [Indexed: 01/11/2023] Open
Abstract
BACKGROUND Periprosthetic fractures are a rare complication after total knee arthroplasty (TKA). However, the incidence of these fractures is growing after the increasing number of TKAs performed every year and the progressive aging of the population. In addition, the surgical treatment and peri-operative management of these complications are demanding, representing a challenge for the orthopedic surgeon. SIGNIFICANCE A thorough understanding of these fractures and a correct classification are necessary in order to select the most suitable surgical treatment. The aim of this review was to analyze the epidemiology, classification, diagnosis, surgical treatment, and outcomes of periprosthetic knee fractures in order to give an exhaustive overview. RESULTS Reduction and internal fixation with locking plates or intramedullary nails represents the preferred option in case of a stable prosthetic implant. Conversely, in case of loose tibial and/or femoral component, implant revision is mandatory. Conservative treatment is rarely indicated. CONCLUSION A deep understanding of the characteristics and patterns of periprosthetic knee fractures, and the determination of the stability of the prosthetic implant are necessary in order to establish the correct treatment.
Collapse
Affiliation(s)
- Giorgio Cacciola
- Orthopaedic Institute of Southern Italy “Franco Scalabrino,” Messina, Italy
| | - Fabio Mancino
- Division of Orthopaedics and Traumatology, Department of Aging, Neurological, Orthopaedic and Head-Neck Studies, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Rome, Italy
| | - Federico De Meo
- Orthopaedic Institute of Southern Italy “Franco Scalabrino,” Messina, Italy
| | | | - Ivan De Martino
- Division of Orthopaedics and Traumatology, Department of Aging, Neurological, Orthopaedic and Head-Neck Studies, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Rome, Italy
| | - Pietro Cavaliere
- Orthopaedic Institute of Southern Italy “Franco Scalabrino,” Messina, Italy
| |
Collapse
|
20
|
Cacciola G, Mancino F, De Meo F, Di Matteo V, Sculco PK, Cavaliere P, Maccauro G, De Martino I. Mid-term survivorship and clinical outcomes of the medial stabilized systems in primary total knee arthroplasty: A systematic review. J Orthop 2021; 24:157-164. [PMID: 33716421 DOI: 10.1016/j.jor.2021.02.022] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/03/2021] [Accepted: 02/14/2021] [Indexed: 12/29/2022] Open
Abstract
Introduction Medial Pivot Total Knee Arthroplasty was introduced in clinical practice in 1990s to reproduce the in vivo-natural knee kinematics. This design is characterized by an asymmetric constraint profile, with aa highly congruent medial compartment, and a less congruent lateral compartment. Short-term outcomes of the medial pivot systems in primary knee arthroplasty have been widely reported in the current literature, however, only few studies have described results beyond 5-year follow-up. Objectives The primary objectives of this systematic review of the literature is to analyze the mid-term studies on medial pivot total knee arthroplasty focusing on the reoperation rate, survivorship and clinical outcome scores. Methods The US National Library of Medicine (PubMed/MEDLINE), EMBASE, and the Cochrane Database of Systematic Reviews were queried for publications from January 1980 to December 2019 utilizing the following keywords: "medial pivot", "medial stabilized", "medial rotating", "medial congruent", medial ball and socket", "arthroplasty", "TKA", "TKR", and "knee surgery". Results 18 articles met the inclusion criteria for the present study. The average quality was 11.4 for non-comparative studies and 21.7 for comparative studies based on MINORS criteria. A total 2832 knee arthroplasties were included for the final analysis with an average age of 69 years, and an average follow-up of 8.1 years (minimum 5 years). The overall reoperation rate was 2.4%, with periprosthetic joint infection as the leading cause of revision in 0.9% of cases, followed by aseptic loosening in 0.4% of cases. The average Knee Society Score improved to a mean preoperative score of 40.1 to a mean postoperative score of 89.2. The functional knee society score improved from a mean preoperative score of 44.8 to an average postoperative score of 82.9. The global range of motion improved from 104.8° preoperatively to 115.6° postoperatively. Conclusion We found that medial pivot system in primary total knee arthroplasty provide overall mid-term survivorship comparable to other standard implasnts. In addition, medial pivot system is associated with better high-end function compared to standard implants.
Collapse
Affiliation(s)
- Giorgio Cacciola
- GIOMI Istituto Ortopedico del Mezzogiorno d'Italia Franco Scalabrino, Ganzirri, Via Consolare Pompea, 98165, Messina, ME, Italy
| | - Fabio Mancino
- Adult Reconstruction and Joint Replacement Service, Division of Orthopaedics and Traumatology, Department of Aging, Neurological, Orthopaedic and Head-Neck Studies, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Largo Agostino Gemelli 8, Roma, RM, 00168, Italy.,Università Cattolica del Sacro Cuore, Largo Francesco Vito 1, Roma, RM, 00168, Italy
| | - Federico De Meo
- GIOMI Istituto Ortopedico del Mezzogiorno d'Italia Franco Scalabrino, Ganzirri, Via Consolare Pompea, 98165, Messina, ME, Italy
| | - Vincenzo Di Matteo
- Adult Reconstruction and Joint Replacement Service, Division of Orthopaedics and Traumatology, Department of Aging, Neurological, Orthopaedic and Head-Neck Studies, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Largo Agostino Gemelli 8, Roma, RM, 00168, Italy.,Università Cattolica del Sacro Cuore, Largo Francesco Vito 1, Roma, RM, 00168, Italy
| | - Peter K Sculco
- Stavros Niarchos Foundation, Complex Joint Reconstruction Center, Adult Reconstruction and Joint Replacement Division, Department of Orthopaedic Surgery, Hospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA
| | - Pietro Cavaliere
- GIOMI Istituto Ortopedico del Mezzogiorno d'Italia Franco Scalabrino, Ganzirri, Via Consolare Pompea, 98165, Messina, ME, Italy
| | - Giulio Maccauro
- Adult Reconstruction and Joint Replacement Service, Division of Orthopaedics and Traumatology, Department of Aging, Neurological, Orthopaedic and Head-Neck Studies, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Largo Agostino Gemelli 8, Roma, RM, 00168, Italy.,Università Cattolica del Sacro Cuore, Largo Francesco Vito 1, Roma, RM, 00168, Italy
| | - Ivan De Martino
- Adult Reconstruction and Joint Replacement Service, Division of Orthopaedics and Traumatology, Department of Aging, Neurological, Orthopaedic and Head-Neck Studies, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Largo Agostino Gemelli 8, Roma, RM, 00168, Italy
| |
Collapse
|