Brandl M, Jahnke A, Fölsch C, Rickert M, Ishaque BA. Mid- to long-term periprosthetic bone density changes after cementless short stem hip arthroplasty in elderly: A clinical and radiological analysis. J Orthop 2024; 57:17-22. [PMID: 38948502 PMCID: PMC11208799 DOI: 10.1016/j.jor.2024.06.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/25/2024] [Accepted: 06/01/2024] [Indexed: 07/02/2024] Open
Abstract
Introduction Short stem prostheses were originally designed for younger and more active patients. In recent years, they have been increasingly offered to older patients. This study evaluates the mid-to long-term survival of a short stem prosthesis and the changes in periprosthetic bone density following implantation of a cementless short hip stem in patients over 60 years of age. Methods 118 patients aged over 60 received short stem prostheses. Clinical examination included Harris Hip Score (HHS) and Hip Disability and Osteoarthritis Outcome Score (HOOS). 93 patients were followed clinically for at least five years. 53 patients underwent dual-energy x-ray absorptiometry (DXA) and radiographic evaluation. Follow-up intervals were preoperative and postoperative (t0), at approximately six months (t1), at approximately two years (t2), and at approximately five years or later (t3). Results Over a mean 6.7-year observation period for all 118 patients, one stem revision occurred due to a traumatic periprosthetic stem fracture. The five-year survival rate for the endpoint survival of the Metha® stem in 95 at-risk patients is 99.2%. HHS improved significantly from t0 55.3 ± 11.5 (range 30-79) to t3 95.3 ± 8.6 (range 57-100) at a mean of 8.0 years (p < 0.001). HOOS improved significantly in each subscale (p < 0.001). Bone mineral density (BMD) was available for review in 53 patients after a mean of 7.1 years. BMD increased from t0 to t3 in region of interest (ROI) 3 (+0.4%) and ROI 6 (+2.9%) and decreased in ROI 1 (-10.3%), ROI 2 (-9.8%), ROI 4 (-5.3%), ROI 5 (-3.4%) and ROI 7 (-23.1%). Conclusions The evaluated short stem prosthesis shows a remarkably high survival rate in elderly patients, accompanied by excellent clinical results. Load transfer measurements show a metaphyseal-diaphyseal pattern with a trend towards increased diaphyseal transfer over the period observed.
Collapse
Affiliation(s)
- Max Brandl
- Laboratory of Biomechanics, Justus-Liebig-University Giessen, Klinikstrasse 29, 35392, Giessen, Germany
| | - Alexander Jahnke
- Laboratory of Biomechanics, Justus-Liebig-University Giessen, Klinikstrasse 29, 35392, Giessen, Germany
| | - Christian Fölsch
- Laboratory of Biomechanics, Justus-Liebig-University Giessen, Klinikstrasse 29, 35392, Giessen, Germany
- Department of Orthopaedics and Orthopaedic Surgery, University Hospital Giessen and Marburg (UKGM), Klinikstrasse 33, 35392, Giessen, Germany
| | - Markus Rickert
- Laboratory of Biomechanics, Justus-Liebig-University Giessen, Klinikstrasse 29, 35392, Giessen, Germany
- Department of Orthopaedics and Orthopaedic Surgery, University Hospital Giessen and Marburg (UKGM), Klinikstrasse 33, 35392, Giessen, Germany
| | - Bernd Alexander Ishaque
- Laboratory of Biomechanics, Justus-Liebig-University Giessen, Klinikstrasse 29, 35392, Giessen, Germany
- Department of Orthopaedics and Orthopaedic Surgery, University Hospital Giessen and Marburg (UKGM), Klinikstrasse 33, 35392, Giessen, Germany
| |
Collapse
|
2
|
Hayashi S, Kuroda Y, Nakano N, Matsumoto T, Tachibana S, Kuroda R. Comparison study of periprosthetic bone remodeling between simultaneous bilateral total hip arthroplasty and unilateral total hip arthroplasty: a matched cohort study. INTERNATIONAL ORTHOPAEDICS 2023; 47:2767-2772. [PMID: 37572119 DOI: 10.1007/s00264-023-05918-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/07/2023] [Accepted: 07/25/2023] [Indexed: 08/14/2023]
Abstract
PURPOSE The load-bearing pattern of periprosthetic bone may differ between patients who underwent simultaneous bilateral and unilateral total hip arthroplasty (THA). We investigated the differences in periprosthetic bone remodeling after simultaneous bilateral total hip arthroplasty and unilateral total hip arthroplasty. METHODS This retrospective cohort study enrolled 154 consecutive patients undergoing THA using full hydroxyapatite (HA) compaction short stems. Patient characteristics including age, body mass index, University of California Los Angeles (UCLA) activity score, and bone shape of the proximal femur were adjusted by propensity score matching. Subsequently, periprosthetic bone mineral density changes were compared between simultaneous bilateral and unilateral THA. RESULTS We found that bone mineral density loss in the simultaneous bilateral THA group was significantly higher in zones 6 and 7 at 24 months after THA (zone 6, p = 0.019; zone 7, p = 0.041). Periprosthetic bone mineral density loss was not associated with clinical factors, including age, body mass index, and daily activity. Additionally, we demonstrated that periprosthetic bone mineral density loss was higher in zones 1, 4, 6, and 7 of patients with a normal hip on the contralateral side after unilateral THA (zone 1, p = 0.041; zone 4, p = 0.041; zone 6, p = 0.037; zone7, p = 0.019). CONCLUSIONS The postoperative periprosthetic bone remodeling was lower in patients who underwent simultaneous bilateral THA than in those who underwent unilateral THA, even though patient characteristics were adjusted by propensity matching. Further observation of periprosthetic bone mineral density loss is needed to clarify the differences between the groups.
Collapse
Affiliation(s)
- Shinya Hayashi
- Department of Orthopaedic Surgery, Kobe University Graduate School of Medicine, 7-5-1 Kusunoki-cho, Chuo-ku, Kobe, 650-0017, Japan.
| | - Yuichi Kuroda
- Department of Orthopaedic Surgery, Kobe University Graduate School of Medicine, 7-5-1 Kusunoki-cho, Chuo-ku, Kobe, 650-0017, Japan
| | - Naoki Nakano
- Department of Orthopaedic Surgery, Kobe University Graduate School of Medicine, 7-5-1 Kusunoki-cho, Chuo-ku, Kobe, 650-0017, Japan
| | - Tomoyuki Matsumoto
- Department of Orthopaedic Surgery, Kobe University Graduate School of Medicine, 7-5-1 Kusunoki-cho, Chuo-ku, Kobe, 650-0017, Japan
| | - Shotaro Tachibana
- Department of Orthopaedic Surgery, Kobe University Graduate School of Medicine, 7-5-1 Kusunoki-cho, Chuo-ku, Kobe, 650-0017, Japan
| | - Ryosuke Kuroda
- Department of Orthopaedic Surgery, Kobe University Graduate School of Medicine, 7-5-1 Kusunoki-cho, Chuo-ku, Kobe, 650-0017, Japan
| |
Collapse
|
3
|
Logroscino G, Saracco M, Maccauro G, Urbani A, Ciavardelli D, Consalvo A, Ferraro D, Falez F. Ceramic-on-metal coupling in THA: long term clinical and radiographic outcomes using two different short stems. BMC Musculoskelet Disord 2022; 22:1065. [PMID: 35193540 PMCID: PMC8864779 DOI: 10.1186/s12891-022-05077-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/30/2022] [Accepted: 01/31/2022] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Hip prosthetic replacement surgery is the gold standard for patients affected by symptomatic osteoarthritis. The ceramic-on-metal hybrid hard-on-hard bearing was initially launched on the market with the purpose of reducing adhesive and corrosion wear, loss of metal debris and ions and risk of fracture and squeaking. However, this bearing was withdrawn from the market, in the apprehension of local and systemic toxicity. The aim of this study is to evaluate the reliability and safety of ceramic-on-metal bearing at long term follow-up. METHODS From 2 cohorts of patients suffering of hip osteoarthritis who underwent total hip arthroplasty using ceramic-on-metal bearing with two different short stems, 19 of the GROUP A and 25 of the GROUP B were suitable for this study. All patients were compared clinically using the Harris Hip Score (HHS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), visual analogue scale (VAS), 12-item Short Form Health Survey (SF12P/M), and radiographically. Blood samples were collected in order to evaluate chromium and cobalt ions level. The two groups were compared in terms of metal ions blood levels, and finally all the implanted prostheses were compared with a healthy control group. RESULTS All the implanted stems were well-positioned and osseointegrated at a mean follow-up of 114 months. Improvements were observed for all clinical scores comparing preoperative and postoperative values in both groups. Radiographic evaluation showed a good ability to restore proper articular geometry. Chromium and cobalt ion analysis revealed values below the safety threshold except for 1 case in GROUP A (cup malposition) and 2 cases in GROUP B (6.1%). No revision occurred. CONCLUSIONS Ceramic-on-metal bearing is safe and reliable at long term follow-up in association to short stems arthroplasty, if the implant is correctly positioned. Chromium and cobalt metal ions blood levels evaluation should be performed annually.
Collapse
Affiliation(s)
- Giandomenico Logroscino
- Mininvasive and Computer-Assisted Orthopaedic Surgery, Department of Life, Health and Environmental Sciences, University of L'Aquila, L'Aquila, Italy
| | - Michela Saracco
- Department of Orthopaedics, Catholic University of Rome-Fondazione Policlinico Universitario A. Gemelli IRCCS, Largo F. Vito,1, 00168, Rome, Italy.
| | - Giulio Maccauro
- Department of Orthopaedics, Catholic University of Rome-Fondazione Policlinico Universitario A. Gemelli IRCCS, Largo F. Vito,1, 00168, Rome, Italy
| | - Andrea Urbani
- Institute of Biochemistry and Clinical Biochemistry, Catholic University of Rome-Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
| | - Domenico Ciavardelli
- School of Medicine and Surgery, University "Kore" of Enna, Enna, Italy
- Center for Advanced Studies and Technology (C.A.S.T.), University "G. d'Annunzio" of Chieti-Pescara, Chieti, Italy
| | - Ada Consalvo
- Center for Advanced Studies and Technology (C.A.S.T.), University "G. d'Annunzio" of Chieti-Pescara, Chieti, Italy
| | - Daniele Ferraro
- Department of Orthopaedics and Traumatology, ASL Roma 1, S. Filippo Neri Hospital and S. Spirito Hospital, Rome, Italy
| | - Francesco Falez
- Department of Orthopaedics and Traumatology, ASL Roma 1, S. Filippo Neri Hospital and S. Spirito Hospital, Rome, Italy
| |
Collapse
|
4
|
Belfrage O, Weber E, Sundberg M, Flivik G. Preserved periprosthetic bone stock at 5 years post-operatively with uncemented short hip stem in both collared and collarless version. Arch Orthop Trauma Surg 2022; 142:3489-3496. [PMID: 34841462 PMCID: PMC9522768 DOI: 10.1007/s00402-021-04225-z] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/06/2020] [Accepted: 10/13/2021] [Indexed: 11/30/2022]
Abstract
INTRODUCTION Previous bone density studies have generally shown bone resorption around both cemented and uncemented total hip arthroplasty (THA) stems. This is presumed to be due to stress shielding. Short stems have been introduced partly to preserve bone in the proximal femur by a more physiological loading of the bone. The purpose of this study was to evaluate bone remodeling around a short, fully hydroxyapatite-coated titanium stem that comes in a collared and collarless version. PATIENTS AND METHODS A prospective cohort of 50 patients included in a study evaluating the Furlong Evolution stem has been followed for 5 years. Examination was done with dual energy X-ray absorptiometry (DXA) postoperatively, at 1, 2 and 5 years. Clinical outcome was followed with radiography and both general and hip specific outcome measures. RESULTS The two versions of the stem behaved similarly regarding bone remodeling. After an initial decrease up to 1 year, bone mineral density (BMD) increased in all Gruen zones up to 2 years and at 5 years bone stock was still preserved compared with postoperatively (net BMD + 1.2% (95% CI - 0.4 to 2.8)). Increase in BMD occurred mainly in the greater trochanter and distally around the stem with a decrease in the calcar area. Both versions showed excellent clinical outcome up to 5 years. CONCLUSION This short stem seems to preserve proximal bone stock up to 5 years, exhibiting similar behaviour both with and without a collar. TRIAL REGISTRATION NUMBER AND DATE OF REGISTRATION ClinicalTrials.gov, (identifier: NCT01894854). July 10, 2013.
Collapse
Affiliation(s)
- Ola Belfrage
- Department of Orthopedics, Skåne University Hospital and Clinical Sciences, Lund University, Lund, Sweden
| | - Erik Weber
- Department of Orthopedics, Skåne University Hospital and Clinical Sciences, Lund University, Lund, Sweden
| | - Martin Sundberg
- Department of Orthopedics, Skåne University Hospital and Clinical Sciences, Lund University, Lund, Sweden
| | - Gunnar Flivik
- Department of Orthopedics, Skåne University Hospital and Clinical Sciences, Lund University, Lund, Sweden
| |
Collapse
|
5
|
Drobniewski M, Synder M, Synder MA, Krasińska M, Olewnik L, Borowski A. Future of total hip arthroplasty with the Metha short stem in modern surgeries. Sci Rep 2021; 11:21763. [PMID: 34741121 PMCID: PMC8571394 DOI: 10.1038/s41598-021-01367-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2021] [Accepted: 10/25/2021] [Indexed: 12/02/2022] Open
Abstract
The aim of the study was to analyse the results of uncemented total hip replacement, using the Metha (metaphyseal) stem. A total of 158 patients (70 females and 88 males) were qualified to the study and submitted to total hip arthroplasty (183 procedures altogether), using the Metha stem. The mean age of the patients on the day of surgery was 51.7 years (the range from 17 to 69 years). The mean follow up period was 9.2 years (the range from 5 to 13.5 years). Preoperative assessments gave poor scores, according to the Merle d’Aubigne and Postel classification, modified by Charnley. The average improvement after surgery, according to the used scale, was 6.9 points. A very good outcome was recorded in 154 cases (84.2%), a good outcome was achieved in 20 cases (10.9%) and a poor outcome was confirmed in 9 cases, while no satisfactory case was observed. Poor outcomes were associated with implant loosening. Extraskeletal ossification was noted in 10 cases (5.5%). According to the Kaplan–Meier estimator, the 10-year survival was 93.2% and 97.3% for the whole implant and the stem alone, respectively. 1. Our follow-up period of more than 9 years on the average, indicates that Metha stems produce excellent clinical and functional results in operated young patients with advanced degenerative changes of the hip joint. 2. Assuming a proper qualification for the procedure, the absence of complications and a correct surgical technique, which is slightly more difficult, when compared to standard stem implantation, the risk of aseptic loosening is fairly negligible.
Collapse
Affiliation(s)
- Marek Drobniewski
- Orthopaedics and Paediatric Orthopaedics Department, Medical University of Lodz, ul. Pomorska 251, 92-213, Lodz, Poland
| | - Marek Synder
- Orthopaedics and Paediatric Orthopaedics Department, Medical University of Lodz, ul. Pomorska 251, 92-213, Lodz, Poland
| | - Marek Aleksander Synder
- Orthopaedics and Paediatric Orthopaedics Department, Medical University of Lodz, ul. Pomorska 251, 92-213, Lodz, Poland
| | - Magdalena Krasińska
- Orthopaedics and Paediatric Orthopaedics Department, Medical University of Lodz, ul. Pomorska 251, 92-213, Lodz, Poland
| | - Lukasz Olewnik
- Department of Anatomical Dissection and Donation, Medical University of Lodz, Lodz, Poland
| | - Andrzej Borowski
- Orthopaedics and Paediatric Orthopaedics Department, Medical University of Lodz, ul. Pomorska 251, 92-213, Lodz, Poland.
| |
Collapse
|